Home

Hilton Photovoltaic Trainer RE540

image

Contents

1. complex analysis Additional Data Logging Facility Supplied As Standard The D103 is the third generation of Hilton Data Logger It comprises an industrially proven 21 channel interface with 8 thermocouples type T and K as standard differential voltage inputs 100mv DC 8 single ended DC voltage inputs 8v 4 logic or frequency inputs and one mains voltage input In addition there are on board 12v DC 5V DC and 15v DC power supplies for most commercially available transducers P A Hilton Ltd The Hilton Data Logging software supplied as standard with the RECS541A package allows the D103 to be disconnected from the RE540 and used together with most standard transducers as a stand alone computer data logger for the instrumentation and monitoring of existing laboratory equipment using locally sourced industrial transducers The software is also backwards compatible with our many second generation D102 data loggers that are already in use worldwide Full data logger command protocol and communications details are provided in an extensive user manual that allows other software applications to communicate with the logger via the USB interface Users can write their own software typically in LabView Matlab C C Visual Basic etc This further expands the student project capabilities of the REC541A package from teaching and demonstration into the field of research and postgraduate study Computer Hardware Requirements T
2. P A Hilton Ltd gt Hilton Photovoltaic Trainer RES540 Demonstrates the Practical Application of a Solar Power Generation System Expandable 80W Panels and Deep Cycle Batteries Allow Substantial Loads to be Applied Optional Solar Simulator Available Optional Computerised Data Acquisition gt Safe for Student Operation Two Year Warranty Page 1 of 5 Version 7 Introduction Solar power is one of the few truly renewable energy sources that is currently commercially available Ongoing research and the expansion of production facilities for photovoltaic panels means that capital costs for practical installations are reducing The reality of global warming and carbon taxes related to the burning of fossil fuels means that interest in solar power generation is expanding beyond novel applications to more mainstream situations As solar panels are almost never used without a method of power storage it is important that engineers architects and designers are aware of the advantages and limitations of the various types of photovoltaic panel controls and battery systems that are available In addition an understanding of the method of generating readily useable alternating current from the direct current of the battery is also essential The Hilton Photovoltaic Trainer RE540 will provide interesting and instructive experimental work for all students and will be of particular interest to those studyin
3. adiation incident on the panel kW m to be measured and compared with the electrical power generated This enables system efficiency to be measured The instrumentation provided allows the isolated panel characteristics and the overall system performance to be measured under load A monitoring point is provided to allow detailed investigation of the charge controller operation by advanced _ students Oscilloscope required not provided as standard In order to expand the capacity of the unit additional panels and batteries are available as optional extras To allow long term monitoring of system performance an optional data acquisition system 1s available that can be supplied as a factory fitted option or alternatively for addition as a user fitted accessory In order to demonstrate the use of solar power for AC power generation an optional inverter is available For environments where abundant solar radiation cannot be relied upon an optional solar simulator See RES40E is available that requires connection to a local electrical power supply The RE540 unit is complimentary to the Hilton RES550 Flat Plate Solar Energy Collector which allows students to examine water heating directly from solar energy Safety The integral charge control system provides overload protection and battery protection Excluding the optional inverter and solar simulator options all components are low voltage 10 20v DC Where appropriate componen
4. enance manual in English Spanish French Accessories and spares for 2 years normal operation List available on request Services Required If operated in ambient sunlight the unit is self powered and requires no mains services Optional Items The Optional Data Acquisition Upgrade RECS41A and the Optional Solar Simulator RES40E require a mains power supply Details available on request Order as Photovoltaic Trainer Optional Items Water Pump Single Phase Inverter Additional 80W Solar Panel Additional Deep Cycle Battery Solar Simulator Data Acquisition Upgrade Page 3 of 5 Version 7 RES40A RES540B RES540C RES540D RES40E RECS41A NOTE The policy of P A Hilton Ltd is one of continual improvement and we reserve the right to change this specification without notice Optional Extra Details RES40A Water Pump RES540B Single Phase Inverter RES540D Additional Deep Cycle Battery Photograph showing typical Optional RE540A RES540B and RES40D It is essential for students to be aware that components of a practical photovoltaic system must be compatible and designed for purpose if the system is to be successful The optional water pump and single phase inverter are specifically designed for use with photovoltaic systems The single phase inverter allows students to investigate the conversion of battery derived low voltage DC to AC mains power at 230V 50Hz 110v 60Hz available on request The use
5. g e Environmental Engineering Energy Conservation Mechanical Engineering Architecture Building Services Electronics Electrical and Electronic Engineering Automotive Engineering Plant amp Process Engineering The combination of photovoltaic power generation and hydrogen fuel cells represent a potential solution to the storage of solar energy for use on demand P A Hilton Ltd have a Proton Exchange Membrane RE510 Fuel Cell available for training purposes Please refer to our website http www p a hilton co uk for details Experimental Capabilities e Investigation of electrical conversion efficiency relative to solar radiation e Investigation of the effect of panel inclination and angle of latitude e Measurement of solar panel output characteristics under load and the effect of panel temperature e Examination of battery charge management system e Measurement of overall system performance under load P A Hilton Ltd Description A practical sized solar panel with nominal 80W output is connected to a control panel containing relevant instrumentation and a battery charge control system This in turn connects to a substantial deep cycle sealed lead acid battery This allows the application of locally sourced loads or loads available as optional extras The solar panel is supplied with an adjustable stand that allows inclination to be varied together with an accurate panel mounted solarimeter This allows the r
6. grade RECS41A consists of a 21 channel Hilton Data logger D103 together with pre configured ready to use Windows compatible educational software Factory fitted coupling points on the RE540 allow installation of the upgrade to the unit at any time in the machine s extensive life The Hilton Data logger D103 connects using the cable supplied to a standard USB port on the user supplied PC If more than one logger is required connection is via a second USB port or standard USB hub The combined educational software and hardware package allows immediate computer monitoring and display of all relevant parameters on the RE540 Software Details The pre configured menu driven Software supplied with the Computer Upgrade RECS41A allows all recommended experiments involving the electronic transducers and instruments on the RE540 to be carried out with the aid of computerised data acquisition data storage and on screen data presentation This enhances student interest and speeds comprehension of the principles being demonstrated Students are presented with either raw data for later hand calculation or alternatively data may be transferred to most spreadsheets for computerised calculation and graphical presentation Data may be stored on disc and displayed at any time using the software supplied Alternatively data may be transferred to any compatible spreadsheet together with individual time and date stamp on each reading for
7. he menu driven Software supplied with the Computer Upgrade RECS41A will operate on a PC which has at least 0 5Gb Mb ram VGA graphics 1Gb hard drive CD drive and an available USB port The software is Windows 2000 XP and 7 compatible P A HILTON Ltd Horsebridge Mill King s Somborne Stockbridge Hampshire SO20 6PX England National 01794 388382 International 44 1794 388382 Telephone Fax National 01794 388129 International 44 1794 388129 sales p a hilton co uk www p a hilton co uk E mail Website SCAN ME WITH Page 5 of 5 Version 7 NOTE The policy of P A Hilton Ltd is one of continual improvement and we reserve the right to change this specification without notice
8. of standard vehicle batteries with photovoltaic systems is impractical as these devices are designed for short duration high current draw vehicle starting and then rapid re charging Solar panel batteries must be capable of repeated long duration deep discharge and then slow re charge without damage The optional RES540D is purpose designed for use with a solar array Additional optional batteries RES540D and optional solar panels RE540C allow a system with greater capacity to be constructed at any time for demonstration and research purposes pa P A Hilton Ltd TEA RE540C Additional 80W Solar Panel A high quality nominal 80W 12v solar panel Area 0 6m suitable for continuous external use Up to 4 of the optional RES540C panels may be attached to the standard RE540 console together with an unlimited number of the optional RE540D deep cycle batteries RE540E Solar Simulator In countries where solar radiation cannot be relied upon the Optional Solar Simulator allows The RE540 unit and solar panel to be investigated in detail under controlled conditions The full equatorial solar heat flux can be simulated with the Optional RES40E Page 4 of 5 Version 7 NOTE The policy of P A Hilton Ltd is one of continual improvement and we reserve the right to change this specification without notice Optional Extra RECS41A Data Acquisition Upgrade Hardware details The Optional Computerised Data Acquisition Up
9. ts are protected by overload circuit breakers or fuses Page 2 of 5 Version 7 NOTE The policy of P A Hilton Ltd is one of continual improvement and we reserve the right to change this specification without notice P A Hilton Ltd Specification General A complete 80W solar panel system with instrumentation panel containing a battery charge controller panel loading system all relevant instrumentation and an external deep cycle 110Amp hour battery Instrumentation includes high accuracy solarimeter panel temperature electrical charging and load power measurement The system may be expanded by the addition of extra optional solar panels and batteries Computerised data acquisition a solar simulator external loads and an inverter are also available as optional extras Detailed Solar Panel High quality nominal 80W 12v solar panel Areal 0 6m suitable for continuous external use Optional expansion up to 4 panels per unit Instrumentation and Control Instrumentation panel containing battery charge controller panel loading system power and panel temperature measurement power outlet and integral safety cut outs Battery Deep cycle sealed lead acid 110Amp hour Additional batteries available as optional extra Dimensions Nominal overall depending upon panel inclination Height 1200mm Depth 750mm Width 527mm Weight 42 kg Accessories and Spares Unit supplied with One experimental operating and maint