OPM-4260 MFC User Manual
Contents
1. sss 5 Remote Controller 6 04 New MFC Installation 8 05 How to use Remote Controller 10 Oe n 10 05 2 BROADCAST 10 05 3 AUTO Tracking PC Mode Only 11 4s 11 05 5 Mode 05 6 Input Selection eene 20 05 X x Y Configuration e g Horizontal 5 sets x Vertical 6 sets 23 05 8 BIC control Setting Only applicable to OPM 4250 OPM 4250R 25 05 9 Baud Rate 26 O6 Before calling for 1 27 07 SSC INC AU OI 28 ORION CO LTD 1 New Multi Function Controller 014 oafety Precautions B Cautions for New Please do not use at the places Do not touch the power cable Do not store or use flammables of hot and humid environment with wet hands like a combustible spray around may damage the product may cause an electric shock the product It has a possible danger of explosion or fire Do not put the product under Do not disassemble repair or alter the If you detect smoke smell or strange sound the direct sunlight or near to hot product with users
2. tor ort Select From PC Daisy chain In To PDP Daisy chain Out Check BIC Mode Test LED Test ALL Check X by Y Ethernet Configuration f Enable Diasable Set TCPAP Info LCE E EEEE E Get MAC Address Set Default TCP IP End of Execution Result Get Network Configuration Version BIC On Off X by Y IP Address 121 SubNet Masi 255 DNS Server 168 DNS Servers 168 126 3 6 2 Mus 0 fo po bp B Raw Data Viewer Tx App Module Rx Module App 6 Press Get TCP IP Info and check the IP address gt PIC for OPM 4250 Configuration Program 1 0 Comport Select CLEAR CLOSE Com Port COMO01 Execution Check Version Test Only ort Select f From PC Daisy chain In Test for MFC To PDP Daisy chain Out Check BIC Mode Test LED Test ALL Check X by Y Ethernet Configuration oF Sm m m mum WB Get TCPIP Info 8 Enable DHCP Diasable Set Info Get MAC Address Set Default TCP IP End of Execution Result Get Network Configuration Version BIC On Off X by Y SubNet 255 Gate Way 121 DNS Server 168 DNS Server 168 63 MAC fo fo fo fo 4 m Raw Data Viewer Tx amp pp Module Rx
3. RS 232C HP New MFC MSCS control PC Infinitely Expandable MPDP How to install USB driver 1 Download a proper driver that fits FT232R type from http www ftdichip com Drivers VCP htm 2 Unzip the downloaded file CDM 2 04 16 WHQL Certified zip 3 When the New MFC and a computer is connected it searches the driver for a new device Set the path to the folder that the unzipped file is saved and start driver installation 4 USB Serial Port is registered at the Control panel The communication port number is shown as COM23 The number of each USB port may be changed New Multi Function Controller Infinitely Expandable MMP DP 05 6 Input Selection Input Selection All inouts are executed as full screen mode This function is used for a DVI converter sold separately It indicates various inputs and outputs with a DVI converter It receives Computer HDMI DTV VIDEO S VIDEO DVI and HDSDI as input 1 DVI source converts to sends to MPDP DVI CONVERTER INPUT 1 Press DVI button New is designed to control the input sources o
4. own intention from the product stop using the product places t may cause an electric shock or fire If you immediately disconnect the power cable and It may cause fire need to test adjust or repair the product contact with an authorized service center contact with an authorized service center t may cause an electric shock or C er N Do not spray water directly on Carefully move the product not to Please do not stack heavy the product give any shock objects on top of the product t may cause an electric shock or fire may cause product malfunction may damage the product Please be careful not to soak Please keep away from unknown material or liquid into children s reach the product lf they drop Remote Controller it may t may damage the product hurt the children or cause product malfunction AA rr 2 ORION CO LTD Infinitely Expandable MPDP Cautions for Adapter Use the provided adapter Do not touch the adapter with Make sure the power plug is Improper adapters may damage wet hands properly connected the product If you cannot use the t may cause an electric shock Loose connection may cause an provided adapter use the adapter o electric shock MP wy Do not put a heavy object on the Do not connect to multi Disconnect the power plug on cable or fold the cable power socket
5. It helps avoiding possible undesirable communicational distortion from multiple daisy chains B Advantages 1 Expand the communicational functions of MPDP Serial USB Ethernet IR 2 Prevent possible communicational distortion from using Serial port by 4 channel serial port It transmits the information for BIC by communicating with MPDP without additional applications Only applicable to OPM 4250 OPM 4250R 4 Control the main functions of MPDP and DVI converter by a remote controller without additional applications 4 ORION CO LTD Infinitely Expandable MPDP 03 User Guide Information B Remote Controller POWER ON OFF Turn on off MPDP ID Setting Set the number of MPDP in horizon tal and vertical positions XxY X x Y Setting Enter X x Y setting mode Direct amp Info key Select directions to set the number of MPDP horizontal or vertical and check the status of MPDP DVI CONVERTER INPUT BROADCAST Broadcast is the function to control all MPDP sets at once It is applied for Power On Off and Auto tracking MPDP Input select Select DVI input of MPDP DVI 1 or DVI 2 Function Enter to the test mode of New DVI Converter Input Select Select source input for DVI converter GC C DVI Converter Output M me IO DVI Converter INFO AUTO Select DVI Converter output OUTPUT FUNCTION Check the current status information DVIC1 or DVIC
6. Module App 16 ORION CO LTD Infinitely Expandable MPDP 3 Serial mode Serial communication is performed based on RS 232C specification New MFC allows long distance communication by compensating Communication signals because the signal strength may be decreased by daisy chain connection 1 To execute Serial mode press RS 232C LED switch on the front side of New MFC 2 To control MPDP connect to a computer and use MSCS program Corresponding port should be selected IR ETHERNE RS232 USB RS 232C DVI Signal Distributor UXGA UP TO 165MHz Ro 232C MSCS control PC ORION CO LTD 17 New Multi Function Controller 4 USB mode USB communication is performed based on RS 232C specification too The external interface is USB type and it is converted to RS 232C internally 1 To execute USB mode press USB LED switch on the front side of New MFC 2 To control MPDP connect to a computer with USB cable and use MSCS program Corresponding port should be selected OUTPUT INPUT sn o bx E x o Um 9 o m m o To
7. are push button switches and indicators for communication interface Serial IR USB Ethernet Infinitely Expandable MPDP 2 Rear side DC5 9V i N gt a O Q N E Qo XE 126 Gm sene 2 5 z 8 0 B 8 S one A Power connector B Power connection for 5 9V Service Port It is a port for program download and debugging USB Port Type B It is used for communication when the interface is changed to USB mode Ethernet Port If it is directly connected to an external control device Crossover Network Cable must be used If it is connected to a hub Straight Through Network Cable must be used 1 Channel Serial Port R A DSUB female It is a connection port between Main board and sub board 4 Channel daisy chain Serial Port R A 9pin DSUB male It is used to connect with MPDP Each channel can used to connect 25 MPDP daisy chain New Multi Function Controller 04 New Installation 1 Connect RS 232C cable and a power adapter and install at the location of good remote control reception Use L brackets to install at the side of the set 2 Connect a computer and the New with at least one of Ethernet RS 232C and USB port and connect the MPDP to the RS 232C output in the New Users can control MPDP with one of Ethernet RS 232 USB and IR remote controller 3 Set the number of MPDP units a
8. in the lower right side of 7 segment is turned on BIC is started 5 j a 5 Press SET button to finish the vertical configuration mode 24 ORION CO LTD ORION CO LTD 25 New Multi Function Controller Infinitely Expandable MMP DP 05 9 Baud Rate Configuration Before calling for service 1 New MFC can be used as a communicational distributor for any devices with its various Before calling for service check the following and then contact the dealership communicational speeds where you purchased this product 2 To configure the baud rate adjust the baud rate switch SW6 which is circled at the 1 New MFC is not turned off even after MPDP power cable is lower right corner of the following picture disconnected Vero o ack Ve Ie I p LADI Z APAN FETS NEN ANNUI aS Dut MUS Ege Ls aiU taii a De PA New MFC and MPDP set work with the independent power supplies When you need to turn on the MPDP again please connect power cable and press ON button in the New If you want to turn off New please disconnect the power cable of the New A P P f E 14143 44d LU l 2 New MFC does not work with no reason Please disconnect and reconnect the adapter SW6 is used for BIC on off Pin No 1 and baud rated configuration Pin No 3 5 commonly Please replace batteries of the remot
9. 2 of DVI converter and execute Auto tracking PDP REMOTE CONTROL 1 Note 2 How to mount batteries Use two 1 5V AAA type batteries Do not mix old and new batteries Do not mix different types or makes of batteries Mixed use of Alkaline Manganese or Re chargeable batteries are NOT recommended e Only use two batteries of the same type and make e Slide the cap at the rear side of the remote controller to open Insert batteries with the correct polarity and close the cap ORION CO LTD 5 New Multi Function Controller B New MFC PWR OFF PWR ON 1 Front side 71818 DVI 1 2 VER fl 2 x T E S VIDEO A Power On Indicator It is turned on when Power On command is received from the remote controller B Power Off Indicator It is turned on when Power Off command is received from the remote controller C MPDP configuration Indicator It indicates the configuration of X x Y in the 7 segments D IrDA Receiver It is the reception position for the IR signal from the remote Controller E Indicator for DVI Input selection of MPDP It is turned on for DVI1 channel and turned off for DVI2 channel F Input Mode Indicator It indicates the current input Source G DVI Converter DVI Output Indicator It indicates the current DVI output H Converting switch and indicator for communication Interface They
10. 9 Vertical Number Minimum interval between button input 0 6 second Specification can be changed without prior notice to improve product quality 28 MEMO Infinitely Expandable MPDP 29 New Multi Function Controller MEMO 30 ORION CO LTD
11. New Multi Function Controller o 504 ID SETTING CO ORION CO LTD www oriondisplay net DTV HDMI gt DVI HDSDI S VIDEO c o DVIC DVIC2 INFO AUTO VIDEO 8 16 Address 257 6 Gongdan dong Gumi si Gyeongsangbuk do Korea FUNCTION OUTPUT Fax 82 2 6678 8599 Tel 82 2 6678 8533 User s Manual Thank you for purchasing our New Multi Function Controller Please read through this user s manual for safety before installing this product This product is manufactured for Multi Plasma display model only 0 60 LLOC New Multi Function Controller Product amp Accessary Please check remote controller and all the accessories are included in the DOX PDP REMOTE CONTROL Remote Controller 1EA Multi Function Controller 1EA New Multi Function Controller Q AAA Te RS 232C Cable 1EA Battery AAA 2EA Bracket 2EA Adapter 1EA box 1EA Infinitely Expandable MPDP Contents 01 Safety Precautions sss 2 Cautions for New 2 Cautions for 9 02 Product Introduction ss oer ir detiene 4 iiesseoss 4 gj 4 Advantages 4 03 User Guide Information
12. PC Mode Only It is available only with PC mode When it is connected with DVI converter Auto Tracking is used to correct the distorted screen alignment 1 Press AUTO button d dis 8 ili 2 Auto Tracking is performed MPDP 05 4 DVI Selector BROADCAST is a command to make all MPDP perform Power On Off or Auto Tracking simultaneously 1 Press BROADCAST button 2 When the LED dot in the 7 segment at the lower left side unit is turned on Broadcast command is executed 10 ORION CO LTD It is used to select DVI 1 input or DVI 2 input n 1 Press DVI 1 or DVI 2 buttons in the Remote controller 2 When the LED is turned on MPDP output is DVI 1 and when it is turned off MPDP output is DVI 2 ORION CO LTD 11 New Multi Function Controller Infinitely Expandable MIP DP 05 5 Mode change There are four interface Ethernet USB RS 232C and IR Remote control 2 Ethernet mode Users can select the mode mE Press one of the four LED switches to select a mode you want Ethernet interface is based on TCP IP Protocol According to DHCP setting it can be used as dynamic IP or static IP Long distance control with World Wide Web and internet 1 IR mode communication through HUB or Switch are available IR interface is designed to execute some MPDP commands through the wireless infrared communication It includes some tests and functions to configure Ethernet
13. e controller 3 Baud Rate Configuration Switch SW6 3 4 5 Mode 3pin 4pin 5pin 9600bps On On 19200bps Off On Daisy chain In 5 600bps On Off 115200bps Off Off 9600bps On Daisy chain Out 115200bps Off 26 27 07 opecification Product Name New Multi Function Controller Specification Remote Controller NEW MFC Name MPDP REMOTE CONTROL Power 1 5V Battery AAA 2EA Size 55 W x 190 L x 25 H mm Environmental Condition 100 400 Weight Voltage 130g 5 9V DC 1 25W MAX Power Consumption 250mA Max 5 9V Size 58 W x 216 L x 46 H mm Environmental Condition 40C 20 809 RH Weight Size 480g 35 W x 80 L x 86 H mm Input 90 264V 47 63Hz Output 5V 2000mA Output Jack Input Output Specification NEW MFC Terminal Name 2 19 Internal diameter Vcc 5 50 External diameter GND Terminal Specification Control Input RS 232C D Sub 9Pin Female Baud Rate 115200 Ethernet RJ 45 TCP IP Type B USB2 0 Max 15m left right 45 standard 3m Key Button Control Mode Select IR Ethernet RS 232C USB Control Output RS 232C 4ea Baud Rate 115200 D Sub 9Pin Male Max 15V MPDP ID Setting Segment LED MPDP Horizontal Number 179
14. f DVI converter easily eA eer 1 When the input source of the DVI converter is selected by MSCS program on the computer or the remote controller of New the corresponding LED is turned on 2 DVI LED is on 2 Two outputs of the DVI converter can be selected and the corresponding LEDs are turned on 2 PC DVI RISE eT 1 Press PC button ID 1 ID 2 ID 3 2 PC LED is on W ID 4 ID 5 ID 6 s B Ei i M DVI CONVERTER INPUT 1 Press DIV button D ID 7 ID 8 ID 9 S COT ad y VIDEO S VIDEO New MFC RS 232C 4 E 2 DTV LED is on s Oe q DTV DVI Signal Distributor UXGA UP TO 165MHz Video Signal RS 232C MSCS control PC 20 21 New Multi Function Controller 4 VIDEO DVI CONVERTER INPUT 1 Press VIDEO button e cm e Gu 2 VIDEO LED is VIDEO 9 S VIDEO DVI CONVERTER INPUT 1 Press S VIDEO button a 2 S VIDEO LED is on S VIDEO 6 HDSDI DVI CONVERTER INPUT 1 Press HDSDI button Ce aE QD GG E HDSDI 2 HDSDI LED is on 7 HDMI DVI CONVERTER INPUT 1 Press HDMI button Ge qe me ccc 2 HDMI LED is on HDMI 22 ORION CO LTD Infinitely Expandable MPDP 05 7 X x Y Configuration e g Horizontal 5 sets x Vertical 6 sets Horizontal configuration 1 Press SET button 2 Press Left and Right buttons sequential
15. ly to enter the horizontal configuration mode 3 When the 2 LEDs at lower right corner of each 7 segment of Horizontal line in the New MFC are turned on the horizontal configuration mode is started 4 Use the number buttons to set the numbers of MPDP sets in horizontal line e g If you want to set 5 for horizontal number press 0 for the tens digit and 5 for the units digit 5 Press SET button to finish the horizontal configuration mode ORION CO LTD 23 New Multi Function Controller Infinitely Expandable MIP DP 05 8 BIC control Setting Only applicable to OPM 4250 OPM 4250R BIC Burn In Compensation function is to reduce the visible burn in effect on the screen by the communication with MPDP through New Vertical configuration MFC 1 Press SET button 1 There is BIC On Off switch on the main board for BIC Control Setting See the white circle lower right corner of the following picture 2 Press Up and Down buttons sequentially to enter the vertical configuration mode 3 When the 2 LEDs at lower right corner of each 7 segment of Vertical line in the New MFC are turned on the vertical configuration mode is started ON KSD525 4 Use the number buttons to set the numbers of MPDP sets in ue OD cu d m Vertical line e g If you want to set 6 for vertical number press for the tens digit and 6 for the units digit BIC OFF 3 When the LED dot
16. ress 1 Change to IR mode press B B A A buttons the remote controller sequentially IR ETHERNET RS232 USB gt PIC for OPM 4250 Configuration Program v1 0 mi 2 When the two LED dots in upper 7 segment are turned on test mode is started 5 jo PUH Haseu Uoi Check BIC Mode Test LED Test ALL Check X by Y serere wcp C fe E Fru Pe Set Info Get MAC Address Set Default 3 Load the provided program by executing PIC Configuration exe in your computer A status window is popped up as shown in the following picture Serial port cable must be connected 4 Match the Com Port and press OPEN and click Test for PIC for OPM 4250 Configuration Program v1 0 COM01 Check Version n From re Unis fo poH Uaza HOA Check BIC Mode Test LED Test ALL Check X by Y Cv Set Info Get Info pucp Get MAC Address Set Default e Mira Ie Get Info Set Info Get MAC Address Set Default TCP IP End of Execution 14 ORION CO LTD ORION CO LTD 15 New Multi Function Controller 5 Type IP address and press Set TCP IP Info gt PIC for OPM 4250 Configuration Program 1 0 Comport Select CLEAR CLOSE Com Port 1 Execution Check Version Test Only wc
17. s instructed in Configuration Mode in the manual Initial setting is 3X3 4 The LED lamps in the New MFC indicate the previous or initial input source at first please select input source once again after power supply Default previous input source Caution Please do not directly expose the IrDA Receiver to fluorescent lamps It may cause malfunction Bracket PWH OFF DVIC2 ORION IR ETHERNET USB New MFC Infinitely Expandable MPDP RS 232C OUTPUT INPUT SS il RS 232C DVI Signal Distributor UXGA UP TO 165MHz 5 232 USB Ethernet ey MSCS control PC Video Source Remote Controller New Multi Function Controller 05 How to use Remote Controller 05 1 Power ON OFF Every command is executed on all MPDP sets 1 POWER ON m m 1 Press POWER ON button on a il 2 MPDP is turned on as the PWR LED of the New is turned PWR ON PWR OFF on O Q 2 POWER OFF m m 1 Press POWER OFF button BEN 2 MPDP is turned off as the PWR LED of the New MFC is turned PWR ON PWR OFF off Q 05 2 BROADCAST Infinitely Expandable MPDP 05 3 AUTO Tracking
18. settings The signal from the remote controller is converted to RS 232C signal as defined in the protocol 2 To control MPDP connect to a computer and use MSCS program and send to MPDP Corresponding port should be selected 1 To execute Ethernet mode press Ethernet LED switch on the front side of New MFC 1 To execute IR mode press IR LED switch on the front side of New MFC 2 When you press IR LED switch the other communication modes are not working 3 For better IR performance MPDP set configuration is necessary Configure the number of X and Y as installed ID 2 ID 3 ID 2 ID3 1 26 F ID 5 ID 6 052 n di ID 8 ID 9 xc 3 ID 8 ID 9 x RS 232C ip QE as New MFC RS 232C DVI Signal Distributor UXGA UP TO 165MHz Ethernet z or Router a4 EERO 13 Remote Controller New Multi Function Controller Infinitely Expandable MIP DP add
19. together with the occasion of lightning It may cause an electric shock or fire many other electric products it may damage the product It may cause an electric shock or fire gt M Notice to users Class A digital device It is a device designed for business purpose with a safety certificate tor electromagnetic interference which user should Warning semnau oi New Multi Function Controller 02 Product Introduction B ntroduction New MFC Multi Function Controller is designed for functional expansion and compensation in communication and users convenience It provides various communicational interfaces of Serial USB and Ethernet and also provides 4 channel daisy chain port to solve the most critical problem of serial communication Users can find out the status of the product with the LED indicators It is also functioning as a BIC controller and a receiver for Remote controller B Features MPDP is mainly controlled through the Serial communication RS 232C However gradually USB and Ethernet port are replacing Serial port in control devices such as computers New MFC can support either case Based on installation circumstance or Users preference Serial RS 232 USB or Ethernet can be selected Especially Ethernet allows controlling MPDP through LAN network or even with Internet Users can have better communication quality with 4 channel serial port equipped in a New MFC
Download Pdf Manuals