Home

NetGuardianLTEdit

image

Contents

1. First Sunday 2 AM Automatic Time Adjustment NTP Settings Enable DST Check this box to have the NetGuardian LT observe daylight Savings Start Day Select the month weekday and time when Daylight Savings will begin End Day Select the month weekday and time when Daylight Savings will end 3 2 9 Timers tab i Device Edit Connect Help pem gt e SIE System Info Global Options Serial Fort Notification Devices Alarme Controls Analogs Date and Time Timers ID Description Value Units 1 Web Refresh 1000 MSELS Web Refresh This timer indicated how fast the NetGuardian LT s web browser refreshes with updated alarm data 12 How many units of time will pass before the web browser refreshes Units Unit of time for the web refresh 3 3 Quick Start How to Create Alarm Shout Configurations Alarm Shout technology will enable you to create your text to speech alarm notifications or upload your own WAV files This editing software is the preferred method but you can also create your own custom voice configurations using the online RTU voice wizard in the MyDPS area of the website www dpstele com MyDPS 3 3 1 Create Voice Configurations To generate voice config files from currently open configuration 1 Click on the Generate and Upload Voice button at the top of the screen 2 Whe
2. End User shall indemnify DPS Telecom and hold it harmless for and against any and all claims damages losses costs expenses obligations liabilities fees and costs and all amounts paid in settlement of any claim action or suit which may be asserted against DPS Telecom which arise out of or are related to the non fulfillment of any covenant or obligation of End User in connection with this Agreement This Agreement shall be construed and enforced in accordance with the laws of the State of California without regard to choice of law principles and excluding the provisions of the UN Convention on Contracts for the International Sale of Goods Any dispute arising out of the Agreement shall be commenced and maintained only in Fresno County California In the event suit is brought or an attorney is retained by any party to this Agreement to seek interpretation or construction of any term or provision of this Agreement to enforce the terms of this Agreement to collect any money due or to obtain any money damages or equitable relief for breach the prevailing party shall be entitled to recover in addition to any other available remedy reimbursement for reasonable attorneys fees court costs costs of investigation and other related expenses Warranty DPS Telecom warrants to the original purchaser only that its products a substantially conform to DPS published specifications and b are substantially free from defects in material and workmanship
3. Joro DPS Telecom Your Partners in Network Alarm Monitoring NetGuardianLTEdit USERMANUAL NetGuardianLTEdit ex Dee ee Zei E TUTIT HHH WM Copyright 2010 DPS Telecom Visit our website at www dpstelecom com for the latest PDF manual and FAQs April 30 2013 D OC UM104 28100 Software Version 1 0 0 15 Revision History April 30 2013 Added missing parts to section 3 Fixed spelling and formatting errors Changed the options explanations on each page to a table from a list January 18 2012 Added SNMP v2c notification type April 28 2010 Initial release of NetGuardian LT Editor user manual This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied without prior written consent of DPS Telecom All software and manuals are copyrighted by DPS Telecom Said software and manuals may not be reproduced copied transmitted or used to make a derivative work by either mechanical electronic or any other means in whole or in part without prior written consent from DPS Telecom except as required by United States copyright laws 2009 DPS Telecom Notice The material in this manual is for information purposes and is subject to change without notice DPS Telecom shall not be liable for errors contained herein or consequential damages in connection with the furnishing performance or use of this manual Conten
4. Operated When Alarm ie Cleard say When Relay is released say Clear Released Global Options for call settings The Global Options tab allows you to configure call setting options Use the example above and the field definitions below Call Passcode Master password used when calling into the NetGuardian LT when a voice notification has been issued Introduction message heard when first dialing in or receiving a call from the unit User definable name for an alarm set User definable name for an alarm clear 3 2 3 Serial Port Settings 3 Device Edit Connect Help Dee sele el Primary Port Located on back of the unit Reach Thraugh Fort Port Type 237 Enable Heach Through Baud Fr Fort BD Parity 8 bit data no parity Tupe TCP Stop Bits tw RTS Head a RTS Tail Flow Control Primary Port Settings Port Type Select the serial port for your build of the NetGuardian Choose from 202 232 485 Baud Parity Stop Bits Select the appropriate settings from the drop down menu and Flow Control RTS Head Only used if your NetGuardian was built with a 202 modem The most commonly used value is 30 RTS Tail Only used if your NetGuardian was built with a 202 modem The most commonly used value is 10 Reach through Port Settings Enable Reach through Checking this box enables the port to be used as a terminal server Most commonly used to Telnet through the port over LAN to a hub switch or router
5. This warranty expires two years from the date of product delivery with respect to hardware and ninety days from the date of product delivery with respect to software If the purchaser discovers within these periods a failure of the product to substantially conform to the specifications or that the product is not substantially free from defects in material and workmanship the purchaser must promply notify DPS Within reasonable time after notification DPS will endeavor to correct any substantial non conformance with the specifications or substantial defects in material and workmanship with new or used replacement parts All warranty service will be performed at the company s office in Fresno California at no charge to the purchaser other than the cost of shipping to and from DPS which shall be the responsiblity of the purchaser If DPS is unable to repair the product to conform to the warranty DPS will provide at its option one of the following a replacement product or a refund of the purchase price for the non conforming product These remedies are the purchaser s only remedies for breach of warranty Prior to initial use the purchaser shall have determined the suitability of the product for its intended use DPS does not warrant a any product components or parts not manufactured by DPS b defects caused by the purchaser s failure to provide a suitable installation environment for the product c damage caused by use of the product for purposes other
6. nnn sjen nnn n najm sja nnn nnn mjn mjn aje nja mjn nnn nnn nnn nnn nnn mjn nn nj nnn nj nnn jn nnn nnn mjn nan nnn ann nnn jj jn sjen nj nanne nnn nnn mjn jn nn naja sj naj mjn mjn sjen BRR ee ee 2 ee 2 2 2 nE EN eee eee 13 Device Edit Connect Help Deal ee le l wl System Info Global Options Serial Port Notification Devices Alarms Controls Analogs Date and Time Timers ID Description _ Mom Time ms MIN N3 N4 NS NG N NS 1 Control 1 description 600 ml mm IAN IAN AN s Notification User definable description for this alarm input Mom Time ms Momentary time in milliseconds Control on time when you execute the MOM command Notification Devices Check which notification devices 1 through 8 you want to send alarm notifications 10 3 2 7 Analogs tab System Info Global Options Serial Port Notification Devices Alarms Controls Analog Date and Time Timers Advanced Options Chan Description al Units Major Under Minor Under Minor Over Major Over Rey H1 Ne Na Wd NS NB NF Ne En 1 Kn 32 0 42 0 110 0 159 0 E ee ed elk 2 External Temperature 32 0 420 110 0 HOF PEFR HH ES Description On Clear Time Unit OT ype Internal Temperature F Clear MSECS w Set gt External Temperature Clear IMSECS Set OF Cancel Basic and advanced analog configuration Description User definable description for this alarm input
7. 2 00 AM to 11 59 PM Save Close The Notification Devices tab provides up to 3 notification methods that you will assign to the alarm points The display email address when email notification is sent From Email can also be edited in NetGuardian LT Info Tab To Email Trap Community only appears when SNMP is selected under the Type column _ nn Sets f Any Time C fiz zinfo minjam z to 11 h s9 v minfpu z f Any Time C iz Info o minjam to 11 h 5a v minjpu 3 2 5 Alarms tab b Device Edit Connect Help Diele lee Sle amp el System Info Global Options Serial Port Notification Devices Alarms Controls Analogs Date and Time Timers Base Alarms system Base Description OnSet OnClear QualT ime Clual nit QualT ype N2 N3 N4 NS Ne NY Ne Enter Base Alarm 1 description here Alarm Clear MSECS Both T Rx EEE EE MN Enter Base Alarm 2 description here Alarm Clear MSECS Both vee nin MN Enter Base Alarm 3 description here Alarm Clear MSECS Both d KE 5E amp ml N Enter Base Alarm 4 description here Alarm Clear MSECS Both l E ae N Pl User definable description for this discrete alarm input One User definable description condition that will appear for this alarm on Set User definable description condition that will appear for this alarm on Clear QualTime Qualification time Length of time that must pass without interruption in
8. From a command prompt type the following note the spaces between each entry telnet IP address port Example telnet 192 168 1 100 3000 Port Port number used for reach through to a serial device select TCP or UDP traffic to be passed through to a serial device 3 2 4 Notification Devices Tab Dale see SiS amp wl System Info Global Options Serial Port Notification Devices Alarms Controls Analogs Date and Time Timers From Email sitedialer dpstele com Notification Summary Enable Type IP Address Port Trap Communit Schedule 1 Schedule 2 NIT snmp A ee Stn Mon Tue Wed ThuFiSat SunMon Tue Wed ThuFisat Use 20 P 12 00 AM to 11 59 PM 12 00 AM to 11 59 PM NT fem ff 8 SunMon TueWed Thu FriSat SunMonTue Wed ThuFriSat 12 00 AM to 11 59 PM 12 00 AM to 11 59 PM N3T femal Af Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat 12 00 AM to 11 59 PM 12 00 AM to 11 59 PM Nar emai i 8 SunMonTueWedThuFisat SunMon Tue Wed ThuFiSat 12 00 AM to 11 59 PM 12 00 AM to 11 53 PM NSC emi Amf Sun Mon Tue Wed ThuFii at Sun Mon Tue WedThuFiiSat 12 00 AM to 11 59 PM 12 00 AM to 11 59 PM ner emi dT StnMonTueWedThuFriSat SunMon Tue Wed ThuFriSat _ 1200 AM to 11 59 PM 12 00 AM to 11 59 PM Nz Emi AB Sun Mon Tue Wed ThuFriSat Sun Mon Tue wed Thu Fri Sat 12 00 AM to 11 59 PM 12 00 AM to 11 59 PM Nef fem A fo SunMonTueWedThuFriSat SunMonTueWedThuFriSat 12 00 AM to 11 59 PM 1
9. P version you are running Assign a user name which must be at least 3 characters long For security reasons 3 2 1 1 DCP Responder DCP Responder Enabled DEP Unit ID DCP Fort DCP Responder settings Enabled Check the box to enable DCP DCP Unit ID User definable ID number for this NetGuardian LT DCP address DCP Port Enter the DCP port for this NetGuardian Choose between UDP TCP or serial 3 2 1 2 Ethernet Ethernet Host Name Enable DHCP E IP Address 19 163 1 100 Subnet Mask 209 299 0 0 Gateway 255 25 265 255 DMS Server 1 205 205 255 255 DMS Server 2 205 205 255 255 Ethernet Connection To setup Ethernet ports you will need to use the following field definitions For configuring the LAN Ethernet port you must enter values in the following fields set values to 255 255 255 255 if not using Enable DHCP Toggles the Dynamic Host Configuration Protocol On or Off When DHCP is enabled all addresses will be disabled however IP address The IP address of the NetGuardian LT Path defining whether your packets should stay on your local network or be forwarded to the gateway DNS Server 1 to 2 Enter the IP addresses of the domain name server 3 2 2 Global Options Tab i Device Edit Connect Help Diele ee SE E M Call Options Call Passcode 1 zag Greeting IT his is the MetGuard an LT When Alarm ig Set say When Relay is operated say E tanding
10. Select the appropriate settings from the drop down menu Thresholds Major Under Minor Under Minor Over Major Over Threshold settings These user defined values are used to indicate the severity of the alarm by notifying you when the temperature has passed the values you have set Reverse Check this box to reverse the polarity of the alarm point Left un checked this means a normally open contact closure is an alarm When polarity is reversed a normally closed alarm point is considered clear when closed Advanced Analog Options User definable description condition that will appear for this alarm on Set OnClear User definable description condition that will appear for this alarm on Clear QualTime Qualification time Length of time that must pass without interruption in order for the condition to be considered an alarm or a Clear Unit of measure for the qualification time Example milliseconds QualType Allows you to choose whether you want to apply the qualification time to the alarm Set Clear or Both 11 3 2 8 Date and Time tab Device Edit Connect Help System Info Global Options Serial Port Notification Devices Alarms Controls Analogs Date and Time Timers Automatic Time Adjustment MTP m Time Zone GMT 08 00 Pacific Time Adjust Clock for Daylight Saving Time DST Enable DST u Month Weekday Hour Start Day Mar Second Sunday 2 AM End Dap Moy
11. dit Resource CD and install the software To create a new NetGuardian LT configuration file select New Device under the Device heading To open an existing NetGuardian LT configuration file select Open Device under Device heading and browse for local file To read configuration data from an existing NetGuardian LT select Read from Unit under the Connect heading or press F5 This brings up the Read from Unit window as shown in Figure 1 Enter the IP address of the NetGuardian LT unit you wish to read from enter login and password and click the Read button The configuration information contained in that NetGuardian LT will replace any information that is currently in NetGuardianLT Edit To write configuration data to an existing NetGuardian LT select Write to Unit under under the Connect heading or press F6 This brings up the Write to Unit window It also requires login and password for changes The configuration information contained in NetGuardianL T Edit will replace any information that is currently in that unit s configuration data 3 2 NetGuardianLTEdit tabs 3 2 1 System Info tab Device Edit Connect Help System Info Global Options Serial Port Notification Devices Alarms Controls Analogs Date and Time Timers M System M Version Related Version Device Name NetGuardian LT Device Location a Ethernet Contact Number 559 4541600 GE Host Mame From Email Inetquardian t dpstelecom 0060 s
12. en a User Name admin ame 192 168 1 100 Password Subnet Mask 255 255 0 0 Gateway 255 255 255 255 mn FEST DNS Serverd 255 255 255 255 Set Community dpsowble DNS Server 255 255 255 255 DCP Responder Enabled DCP Unit ID OCF Fort NetGuardian LT Info Tab General Options The NetGuardian LT Info tab provides options for configuring basic NetGuardian LT setup Including login information system information and ethernet connection Device Name Assign the NetGuardian LT a name of your choice For easy identification it s a good idea to assign a name that will be meaningful to everyone who uses the NetGuardian LT Device Location Type in the physical location of the NetGuardian LT This is very useful for keeping track of different units Contact Number Type in a phone number or email address for the person responsible for this NetGuardian LT unit Type in the display email address used in email alarm notifications From Email can also be edited in Notification Devices Tab DPS recommends a minimum length of at least 5 characters The factory default user name is admin Password Assign a password which must also be at least 3 characters long For security reasons DPS recommends a minimum password length of at least 5 characters The factory default password is dpstelecom Get Community Type in the community string for SNMP Get requests Set Community Type in the community string for SNMP Set requests The SNM
13. n prompt appears select start to send POST request Get New Web adn Firmware from MyDPS Generate and Upload New Voice Needs to connect to MyDPS server yore DPS Telecom org DPS Telecom Status Status RERERREAR Start Point descriptions were successfully exported ML file generate Connecting to www dpstele com Connected Sending POST Request This may take several minutes Send Post Request 3 To upload new web and firmware type in NetGuardian LT IP address user name and password Select Check for new firmware to get the latest firmware version Get New Web and Firmware from MyDPS _ ors DPS Telecom Status New Web and Firmware is ready You can upload now or save for later upload via web browser Unit IP 1192 168 1 100 User Name admin Password WV Check for new firmware Save As Cancel a ae Upload New Firmware 4 Click Upload to upload new web and firmware to the unit Or click Cancel to keep current bnd file in install directory 13 5 Click Save As to save new web and firmware to your PC 6 Upload new bnd file to NetGuardian LT via NetGuardian LT web browser 14 4 Technical Support be piela l ejaj amp System Info Global Options Serial Port Notification Devices Alarms Controls Analogs Date and Time Timers Primary Port Located on back of the unit Reach Through Port Be 232 v Enable Reach Through I Baud 3600 Port Pa
14. order for the condition to be considered an alarm or a clear QualType Reverse Check this box to reverse the polarity of the alarm point Left un checked this means a normally open contact closure is an When polarity is reversed a normally closed alarm point is considered clear when closed Notification Devices Check which notification devices 1 through 8 you want to send alarm notifications 3 2 5 1 System Alarms 4 Device Edit Connect Help Diele scale SIE amp wl System Info Global Options Serial Part Notification Devices Alarm Controle Analogs Date and Time Timers System Alarms System IR Base Pnt Description 23 E LG er tion 26 indeed l 27 MAC address not set 28 IP address not zet l 29 LAN hardware error 30 SNMP processing error a ED a LT HNE 71 SNMP community error 32 LAN TX packet drop 33 Notification 1 failed 34 Motification 2 failed 35 Notification 3 failed 36 Notification 4 failed 37 Notification 5 failed 38 Notification 6 failed 39 Notification 7 failed 40 Notification 8 failed 41 NTP failed 42 Timedtick 43 Serial 1 RcvQ full 44 Dynamic memory full A5 Unit Reset 46 Undefined User definable description for this alarm input Ree Report Check this box to choose to report this alarm Notification Devices Check which notification devices 1 through 8 you want to send alarm notifications 3 2 6 Controls tab nanasan
15. rity E bit data no part Stop Bits A NetGuardianLT Edit v1 0 0 15 RTS Head a RTS Tail PD LS DPS Telecom ore Ne Your Partners in Network Alarm Management www dpstele com 4955 E Yale Avenue Fresno CA 93727 800 622 3314 559 454 1600 Click here to go to NetGuardian Online FAQs i Save lau J 2 Link to DPS website DPS Telecom products are backed by our courteous friendly Technical Support representatives who will give you the best in fast and accurate customer service To help us help you better please take the following steps before calling Technical Support 1 Check the DPS Telecom website You will find answers to many common questions on the DPS Telecom website Look here first for a fast solution to your problem http www dpstele com support techfaqs netguardian php 2 Prepare relevant information Having important information about your DPS Telecom product in hand when you call will greatly reduce the time it takes to answer your questions If you do not have all of the information when you call our Technical Support representatives can assist you in gathering it Please write the information down for easy access Please have your user manual and hardware serial number ready 3 Have access to troubled equipment Please be at or near your equipment when you call DPS Telecom Technical Support This will help us solve your problem more efficiently 4 Call during Customer Support hours C
16. than those for which it was designed d damage caused by disasters such as fire flood wind or lightning unless and to the extent that the product specification provides for resistance to a defined disaster e damage caused by unauthorized attachments or modifications f damage during shipment from the purchaser to DPS or g any abuse or misuse by the purchaser THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE In no event will DPS be liable for any special incidental or consequential damages based on breach of warranty breach of contract negligence strict tort or any other legal theory Damages that DPS will not be responsible for include but are not limited to loss of profits loss of savings or revenue loss of use of the product or any associated equipment cost of capital cost of any substitute equipment facilities or services downtime claims of third parties including customers and injury to property The purchaser shall fill out the requested information on the Product Warranty Card and mail the card to DPS This card provides information that helps DPS make product improvements and develop new products For an additional fee DPS may at its option make available by written agreement only an extended warranty providing an additional period of time for the applicability of the standard
17. ts Visit our website at www dpstelecom com for the latest PDF manual and FAQs 1 Introduction 2 Help Menus 3 Configuration 3 1 Getting Started 3 2 NetGuardianLTEdit tabs 3 2 1 System Info tab 3 2 1 1 DCP Responder 3 2 1 2 Ethernet 3 2 2 Global Options Tab 3 2 3 Serial Port Settings 3 2 4 Notification Devices Tab 3 2 5 Alarms tab 3 2 5 1 System Alarms 3 2 6 Controls tab 3 2 7 Analogs tab 3 2 8 Date and Time tab 3 2 9 Timers tab 3 3 Quick Start How to Create Alarm Shout Configurations 3 3 1 Create Voice Configurations 4 Technical Support 5 End User License Agreement Oo OON ARR OONN mh ok i i Li i oF NN O 1 Introduction The NetGuardianLTEdit allows you to create a configuration file without being connected to the NetGuardian LT NetGuardianL TEdit is a necessary component of the NetGuardian LT system It allows you to rapidly manage multiple NetGuardian LTs conveniently and most importantly the NetGuardianLTEdit keeps a separate copy of the database System settings login information point parameters and other information can be provisioned and downloaded to a remote NetGuardian LT via LAN separately from hardware installation NetGuardianLTEdit also enables you to backup valuable provisioning information for easy restoration in the event a re load becomes necessary In addition you can maintain different configuration files for multiple NetGuardian LTs Using the software an installation technician does not ha
18. ustomer support hours are Monday through Friday from 7 A M to 6 P M Pacific time The DPS Telecom Technical Support phone number is 559 454 1600 Emergency Assistance Emergency assistance is available 24 hours a day 7 days a week For emergency assistance after hours allow the phone to ring until it is answered with a paging message You will be asked to enter your phone number An on call technical support representative will return your call as soon as possible 15 gt End User License Agreement All Software and firmware used in for or in connection with the Product parts subsystems or derivatives thereof in whatever form including without limitation source code object code and microcode including any computer programs and any documentation relating to or describing such Software is furnished to the End User only under a non exclusive perpetual license solely for End User s use with the Product The Software may not be copied or modified in whole or in part for any purpose whatsoever The Software may not be reverse engineered compiled or disassembled No title to or ownership of the Software or any of its parts is transferred to the End User Title to all patents copyrights trade secrets and any other applicable rights shall remain with the DPS Telecom DPS Telecom s warranty and limitation on its liability for the Software is as described in the warranty information provided to End User in the Product Manual
19. ve to do any of the unit configuration they simply download the NetGuardianLT Edit configuration file via LAN to the unit they installed This makes installation faster and separates turn up tasks so that they can be performed by different people You can also read configuration files from a remote NetGuardian LT for local editing provisioning by simply entering the IP address and password of your NetGuardian LT NetGuardianLTEdit supports Windows 95 98 NT ME XP and 2000 and NetGuardian LT firmware versions 1 1 3 0 and above 2 Help Menus To access NetGuardianLTEdit help at any time press F1 Additionally fly over help is available in the bottom left hand corner of the NetGuardianLT Edit window when the pointer is hovering over a selected field Note For additional field details or NetGuardian LT information please consult the NetGuardian LT User Manual Configuration Getting Started Read from unit Connection Settings IP Address 192 168 1 100 Login admin Password Connection Status Read NetGuardian LT configuration information by entering the IP address login and password of the NetGuardian LT NetGuardianLT Edit configuration can be accomplished by taking current configuration data and modifying it or by creating a new configuration file and then downloading it to tne NetGuardian LT To get started use the following instructions l 2 Open the NetGuardianLT Edit program from the NetGuardianLTE
20. warranty Technical Support If a purchaser believes that a product is not operating in substantial conformance with DPS published specifications or there appear to be defects in material and workmanship the purchaser should contact our technical support representatives If the problem cannot be corrected over the telephone and the product and problem are covered by the warranty the technical support representative will authorize the return of the product for service and provide shipping information If the product is out of warranty repair charges will be quoted All non warranty repairs receive a 90 day warranty www dpstelecom com