Home
manual-750lph
Contents
1. 3 When the LED s are blink click both buttons RED AND BLACK until you hear a BIP 10 seconds later the machine will begin the scheduled cleaning cycle If you want to pause the decarburization it is enough to click the black or red 17 ECOnovedades 1 0 1 You can restart by pulsing any button it will be heard one BIP and the cycle will continue where it was paused After completed the cycle there will only be one way of the machine to restart a new cycle which will be turning the machine off switch position O in 18 ECOnovedades 1 0 1 DECARBONISATION CYCLES INFORMATION Pressing the black button you will hear one BIP and the LED that indicates the deposit state will turn blue Each time you hear a BIP sound the bubbler LED inform the cycles of cleanings performed as follows EEB t refers to the hundred digits it refers to the ten digits LED It refers to the unity digits It can contain a maximum of 999 Cycles EXITING WITHOUT ERASING THE INFORMATION Pressing the black button will be heard one BIP and the bubbler LED will flash green at a rate of about 2 times sec Turn off the machine switch in position 0 TOTAL RUNNING TIME INFORMATION Pressing the black button you will hear one BIP and the LED that indicates the deposit state will turn green Each time you hear a BIP sound the bubbler LED inform the cycles of cleanings performed as follows 19 it refers
2. ITH KHO AND DISTILLED OR OSMOSIS WATER 22 ECOnovedades 1 0 1 EQUIPMENT TECHNICAL FILE MODEL 750 LPH CAN CLEAN ENGINES TO 7000 CC HHO gas producer works with 210 250 volts Hydrogen Production by Alternating Dry Cell dry cell Adjustable gas production Development and manufacturing in Stainless Steel Complies with EC rules Our machines incorporate safety valves made by measure in Inox 316 L Our sources are designed for intensive use and auto regulate themselves to constantly maintain the required set power even though the voltage swing on the order of approximately 15 23 ECOnovedades 1 0 1 EQUIPAMENT Adjustable timer from 0 to 99 minutes Temperature sensor with automatic ventilation activation and stop Anti return valve stainless steel 316 Viton between deposit and bubbler Flame retainer safety built by measure by Witt Relief valve set to the correct working pressure of 3 5 psi maximum Pressure control gauges in the tank and bubbler LED and sensor of levels with auto stop indication for missing or leftover liquid Emergency stop button Accessible switch Automatic start sensor maximum security LED Display watts amps voltage power factor AC power sources with automatic adjustable frequency with automatic delete system by overheating or a dead short Equipped with wheels to transport Emergency initiation device Cycle co
3. RUNNING TIME INFORMATION eere 19 EQUIPMENT TECHNICAL FIDE curan aaa e saia 23 EQUIPAMEN A O 24 EFFICIENCY cuiastudoianoadaia drid idad 25 Technical specifications of the display pp 26 ECOnovedades 1 0 1 FLAME RETAINER It is only necessary to place the flame retainer when the decarburization is made on gas or LPG engines The warmer the machine becomes the more likely it is that the flame retainer become obstructed and expelling less gas whereby the output pressure gauge will indicate whether if it is necessary or not clean the flame retainer Below we explain how to clean it when necessary ECOnovedades I D i 750 LPH MODEL SCHEME CONTROL PANEL THERMOMETER DEPOSIT MANOMETER TIMER POTENTIOMETER ECOnovedades 1 0 1 MACHINE PREPARATION WE SEND THE MACHINE WITH THE MIXTURE ALREADY FILLED IN THE MAIN DEPOSIT FOR WHICH IS ONLY NECESSARY TO FILL IT WITH OSMOSIS OR DISTILLED WATER PREPARATION AND USE BEFORE TURNING ON THE MACHINE 1 PLUG THE REMOTE START DEVICE Connect the Jack connector on the machine back side and place the device on top of the engine housing It is essential that the place where the device is placed doesn t raise too much the temperature This device detects engine operation by vibration by which turn on and off the machine according if the engine is on or off 2 PLACE THE TUBE IN THE VEHICLE ADMISSION Before starting the
4. User manual 750 LPH KI e I 2015 ECOnovedades 1 0 1 These machines are designed for intensive use They incorporate an automatic cooling system pre set that lights up when the main tank reaches 35 40 C the cooling will continue in function even when the machine is turned off to continue cooling the main tank to restore approximately 35 40 C The maximum temperature that the main tank reaches even with intensive work will be approximately 75 78 C ECOnovedades 1 0 1 INDEX FLAME RETAINER unan sc 4 750 LPH MODEL SO HEME optar a 5 MACHINE PREPARATION pp 6 WE SEND THE MACHINE WITH THE MIXTURE ALREADY FILLED IN THE MAIN DEPOSIT FOR WHICH IS ONLY NECESSARY TO FILL IT WITH OSMOSIS OR DISTILLED WATER 088 6 PREPARATION AND USE nnnc race cen ced cnn 6 BEFORE TURNING ON THE 6 BUBBLER EVE C ory 12 FLAME RETAINER USE ad 13 FLAME RETAINER CLEANING ctr trattare natat rnnt ono dana 13 REPEAT OR EXPAND THE CLEANING IN THE SAME ENGINE 14 DECARBONIZATION PROCEDURE eene 15 ADVANCED FUNCTIONS CONTROL RN 17 TURN ON THE MACHINE WITH THE REMOTE CONTROL 17 HOW TO USE THE RESOURCE REMOTE pp 17 DECARBONISATION CYCLES INFORMATION 19 EXITING WITHOUT ERASING THE 19 TOTAL
5. e will run Once the machine is working it is necessary to control the power by the values indicated in the adhesive using the potentiometer DE 1500 co N 4 5 4 1200 1400 wat DE 7500 cc N 8 9 1750 1900 wat Watt Power Amperes Power factor Where the amps are indicated its possible that appears the symbol HHH this indicates that the amps value that the monitor can show is passed this is not important What matters to us its the power the Watts Regulate between 1200 and 1400 watts for motors above 1500cc Regulate between 1750 and 1850 watts for motors above 7000cc Watts fluctuations 100 100 are normal and are due to changes in volts of the electrical network 200 A 230 VOLT 8 MANOMETERS CONTROL At the beginning of each cleaning control the gauges If anyone of them exceeds the red line turn off the machine Pressure Gauge deposit if exceeds the line means that the valve that is between the tank and the bubbler is blocked in this case would be necessary to contact technical service Gas outlet gauge overcomes the line means that the retainer is blocked ECOnovedades 1 0 1 BUBBLER LEVELS The bubbler must be filled with water from the pipe To easily fill the bubbler you must take the rubber from the gas outlet so that the air can go out and facilitate the water entry Fill the bubbler until the corresponding LED pass from Ed to green If there is na excess of water
6. engine and the machine it s necessary to place the tube which is injecting oxyhydrogen gas in the engine intake ECOnovedades I D i HIDROGENOCEL OFFICIAL REPRESENTATIVE OF ECONOVEDADES GROUP about 10 centimeters close to the turbo or the combustion chamber ATTENTION Fix the tube with a clamp or adhesive tape so that it is not aspirated in the case of turbochargers with powerful suction 3 TURN ON THE SWITCH SWITCH ECOnovedades I D i Wait 10 15s until the LED s turn on 4 REGULATE THE POTENTIOMETER Follow the indications of the sticker on the right POTENTIOMETER 5 REGULATE THE TIMER The timer comes pre set in a 60 minutes cycle TIMER E lt 8 8 z ECOnovedades 1 0 1 HOW TO REGULATE THE TIMER 1 Click once SET and will appear T1 A v cn erssso 1x 2 Click again SET and the time will show 3 Click Or to raise or lower the minutes Possible to adjust until 99 minutes 5 Click FNC and the set time will appear ECOnovedades 1 0 1 6 TURN ON THE ENGINE The machine incorporates a vibration sensor that only allows the machine to start when it detects the vibrations produced by the engine running If the engine stops accidentally the machine will stop as the timer The machine will resume the work when the engine starts running again THIS SAFETY IS OF MAXIMUM IMPORTANCE 7 POWER Control the power in which the machin
7. ntrol and running time device ADJUSTABLE GAS PRODUCTION CADA 190 WATTS PRODUCES 1 LPM 24 ECOnovedades 1 0 1 EFFICIENCY Cleans the engine parts of petrol diesel LPG ethanol vegetable oil methane vehicle namely EGR valve Pistons e Drum Shirt Guns Turbo or not the variable geometry Catalytic converters FAP filter No use of chemicals and without disassembling the engine Recovery of power and torque 10 to 15 Restores 10 al 15 of the lost torque Restores 8 12 of the lost power Restores the yield and initial engine consumption saving of between 5 to 15 consumption Reduces the empty acceleration noise and engine vibrations Increased lifetime of the engine Reduces greenhouse gas emissions from the combustion of fuel Facilitates and enables the visit of ITV in terms of gas emissions unburned hydrocarbons 25 ECOnovedades I D i Technical specifications of the display Voltage 180 and 250 Volt Large amplitude voltage 200V 250V Maximum current 16 A Display Volt 0 250 Display amperes 0 000A 10 View Watt 0 0W 2000W MODEL 750 LPH Empty weight 50Kg Deposit capacity 30L y 26
8. ste from the combustion chamber we should note in a short period of time that the engine sound starts to change due to cleaning valves and other moving engine parts Every 15 20 minutes is recommend to gradually accelerate the engine to 2500 rpm ace keep these RPM for about 15 20 seconds and then take the top for 25 40 seconds This action aims at expulsion of burnt particles accumulated during the process in the exhaust During the treatment you may notice an increase in smoke emission mainly gray corresponding to the incineration of waste accumulated The treatment will have a variable duration depending on the engine capacity and the amount of accumulated carbon REFERENCE TABLE Tourisms and vans 60 Minutes Tractors and industrial 60 70 Minutes vehicles Trucks 90 Minutes 15 ECOnovedades 1 0 1 Once the cleaning ends is recommended to go for a ride with the vehicle about 15 minutes in a forced march to help expelling the accumulated waste in FAP 16 ECOnovedades I D i ADVANCED FUNCTIONS CONTROL TURN ON THE MACHINE WITH THE REMOTE CONTROL THE MACHINE INCORPORATES A COMMAND THAT ALLOWS ITS WORK IN A MANUAL WAY RESOURCE PROCEDURE IN CASE THAT FOR ANY REASON THERE IS NOT WAY TO TURN ON WITH THE SENSOR broken or lost sensor HOW TO USE THE RESOURCE REMOTE 1 CONNECT BEFORE THE JACK FROM THE REMOTE TO THE MACHINE 2 Turn on the machine and wait until the LED s are green in color and blink
9. the LED will turn on blue 12 ECOnovedades 1 0 1 FLAME RETAINER USE The use of the flame retainer its mandatory when you clean GAS or LPG It is not necessary to put it to use the machine for cleaning in diesel engines We also recommend not to put it in the cleaning of diesel engines because it is not necessary that way we have to control it and clean it less often WHEN THE FLAME RETAINER IS USED YOU SHOULD CONTROL THE EXIT MANOMETER REGULARLY EACH 20 30 MINUTES IF THE MANOMETER GOES HIGHER THAN THE RED LINE ITS NECESSARY TO DISMANTLE AND SOPLAR EN ESTE SENTIDO FLAME RETAINER CLEANING IT IS NECESSARY TO BLOW COMPRESSED AIR DURING 7 SECONDS WHERE THE COB IS tube part that goes to the admission this pipe is delivered with the machine and is fixed to the retainer flame with a clip 13 ECOnovedades 1 0 1 CLEANING CYCLE END REPEAT OR EXPAND THE CLEANING IN THE SAME ENGINE If you want to repeat the cleaning in the same car proceed this way 1 Turn off the engine 2 Delete the main switch of the machine 3 Turn the main switch on and wait for the LEDs to become green and blinking 4 Set the time on the timer or leave it as it is 5 Start the engine 14 ECOnovedades 1 0 1 DECARBONIZATION PROCEDURE THE ENGINE MUST BE HOT USUAL TEMPERATURE OF WORK 80 90 We will let the vehicle running so that the orto oxyhydrogen gas do its main function which is the incineration of all wa
10. to the hundred digits LED it refers to the ten digits ECOnovedades 1 0 1 LED It refers to the unity digits It can contain a maximum of 999 Cycles This process will erase the information counter The process is the same for the two modes of information time and cycles When you find information on the time zone or cycles Always keep pressed the red button you will hear one BIP The bubbler LED will consecutively display three colors red green blue if we press at this point the black button It will confirm the delete process by passing the LED to fixed red If for some reason you decide to not complete the delete process simply release the red button before beating the black and will not run the delete command the LED will change to green intermittently Once the process is done turn off the machine switch position 0 20 ECOnovedades 1 0 1 USE RECOMMENDATIONS DON T LEAVE THE MACHINE EXPOSED TO THE SUN OR RAIN DON T SPLIT WATER IN THE BOX OF ELECTRIC POWER DON T SPLIT WATER IN THE ELECTRONIC PARTES CONTROL REGULARLY THE MANOMETERS 21 ECOnovedades I D i MAINTENANCE FILL THE WATER TANK WHEN IS NECESSARY FILL OR EMPTY THE BUBBLER TANK WHEN IS NECESSARY EMPTY THE MAIN WATER TANK ABOUT EVERY 1500 HOURS OF USE OR ONCE EVERY 24 MONTHS RINSE PROCESS ENTER A HOSE WITH WATER FROM THE PIPE and totally rinse 1 2 TIMES THE TANK WHEN THE RINSE IS DONE CALIBRATE AGAIN W
Download Pdf Manuals
Related Search
Related Contents
NanoSync IV Low Profile Marketing Brochure - FEI dreamGEAR DGPS3-1399 Copyright © All rights reserved.