Home
eclipse owners 24-m01-2008.indd
Contents
1. 20 amps 120 volt 60 cycle 15 amps Automatic 2HP geared roller chain variable frequency drive complete with counterweight 10 C to 40 C 14 F to 104 F W36 x L48 x H80 914 mm x 1219 mm x 2032 mm Type 1 2 3 4 5 W36 x L54 x H80 914 mm x 1371 mm x 2032 mm Type 1 2 3 4 5 W36 x L60 xH80 914 mm x 1524 mm x 2032 mm Type 1 2 3 4 5 W40 x L54 x H80 1067 mm x 1371 mm x 2032 mm Type 1 2 3 4 5 Solid melamine or MDF Panels standard unfinished Oak veneer panels optional finished recessed veneer panels optional solid hardwood raised panels optional 50 feet 12 24 m 60 feet 18 29 m available where code permits Relay logic controller complete with diagnostic LEDs Up to 4 stops up to 2 cab openings 6 152 mm minimum up to 96 2845 mm 11 279 mm minimum with buffer springs 96 2438 mm for standard 80 cab 114 2896 mm for 96 cab clear bronze anodized aluminum standard or stainless steel optional or brass optional rectangular standard or oval optional hall stations keyless standard or keyed optional automatic cab on off lighting recessed gate pocket digital display in car operating panel clear or bronze anodized aluminum cab entrance trim and handrail data plates capacity tags proximity floor selection stopping and two way levelling motor access cover locked and switched home landing feature presentation drawings modular r
2. Eclipse Residential Elevator OWNER S MANUAL To Be Retained by Owner After Installation by Authorized Sav ord Dealer 72 CJ C ISAVARIA mE n IMPORTANT Ensure that only an authorized Savaria Concord DEALER installs ser vices and maintains the Eclipse Residential Elevator Under no circum stances is anyone other than a Dealer with Savaria Concord training and authorization to install adjust service or modify any mechanical or electrical device on this lift Failure to follow this warning can result in safety systems compromises or defeat this can result in serious injury or death Savaria Concord Lifts Inc accepts no liability for property dam age warranty claims or personal injury including death in this circum stance Lift and elevator passenger safety is the result of countless details in the equipment s design manufacture and installation After installation reli able operation and continual safe operation requires regular service and inspection at least twice per year or more frequently where usage envi ronment or local jurisdiction require As the owner you re responsible to ensure that regular service and inspections occur in a timely manner Refer to this manual for operating instructions precautions and for us age of the Eclipse Residential Elevator Upon completion of installation the dealer must provide you with the following information and ensure to record it in this manual in addition eith
3. NTENANCE RECORD We recommend that the Owner updates the Maintenance Record after each service call oO Reason for Call Comments Dealer 14 of 14 Eclipse Residential Elevator Owner s Manual Part no 000626 Copyright 2008 Savaria Concord Lifts Inc 107 Alfred Kuehne Blvd Brampton Ontario L6T 4K3 Canada Tel 905 791 5555 Fax 905 791 2222 Toll Free 1 800 661 5112 75 CLIC OISAVARIA COLE CoNcoRnp
4. ail sections unfinished plywood sub floor white ceiling with four incandescent pot lights melamine cab with six different color choices 4 of 14 ECLIPSE RESIDENTIAL ELEVATOR cab gate safety switch pit run stop switch and car top run stop switch emergency stoop and alarm buttons uninterruptible power supply UPS battery backup system for lowering automatic gate operation if equipped and electrical interlock operation and lighting ni the event of a power failure upper and lower terminal limits final limit switch mechanical rail shoring blocks sling factory pre assembled speedy sling c w preset slack chain safety brake and switch Safety features 96 high cab rated speed 50 fpm 0 250 mps available where code permits accordian car gate choice of style stainless steel trim pack brass trim pack automatic gate operator accordian gates only automatic gate swing landing door operator buffer springs 11 pit depth minimum laminate flooring in finished Oak Maple or Cherry interlocks for doors by others Kwiklock or EMI keyed on off control panel and hall stations cab interior in unfinished Oak Birch Cherry or Maple veneer recessed cab panels in Cherry Oak or Maple veneer raised cab panels in solid Cherry Oak or Maple veneer telephone cabinet to match trim custom cab size Options 5 of 14 2 STANDARD FEATURES 1 Cab Key Swit
5. ch Figure 1 A The key switch turns the cab controls ON and OFF It limits the use of the elevator to only persons with authorization 2 Cab Operating Panel Buttons Figure 1 B Automatic Control The Automatic Control Panel buttons facilitate the UP DOWN movement of the cab between landings After pressing a landing button the cab automatically moves to the landing The cab stops once it arrives at the landing 3 Door Open Button Figure 1 C The elevator door gate closes automatically after a pre set adjustable time of 8 seconds Press the door open button to open the door gate once the cab is at a landing 4 Alarm Button Figure 1 D Press the Alarm button to sound the alarm in case of an emergency 5 Emergency Stop Button Figure 1 E Press the Emergency Stop button to Stop the cab and activate the alarm buzzer at any time 6 of 14 Figure 1 Cab Operating Panel 6 Handrail A single handrail is on the Cab Operating Panel side of the cab 7 Emergency Light The cab emergency light remains ON in the event of a main power failure The emergency light uses a Battery Back Up system and includes an automatic recharger 8 Landing Hall Call Station Controls Hall Call Stations at all landings initiate the movement of the cab to the landing An optional key switch limits the elevator s use to only persons with authorization 9 Landing Door and or Gate Interlock The Landing Door Gate lock preven
6. efore the hall buttons become operational This delay allows time for a person to enter exit the cab 8 of 14 4 OPERATING THE ELEVATOR FROM THE LANDING CONTROLS Automatic Operation 1 Insert the key if equipped into the switch on the Hall Call and turn the key to the ON position 2 Press the Hall Call button once and release The elevator automatically comes to your landing 3 Turn the key if equipped to the OFF position and remove the key 4 If required turn the door handle and pull the door open 5 If the cab includes a manual gate slide the gate open and enter the cab 6 Once inside the cab close the gate insert the key if equipped into the key switch and turn the key to the ON position NOTE When using the landing controls the cab can only be moved called to the level from which you are calling When using the control buttons in the cab the cab can be moved to any level WHEELCHAIR WHEELS MUST BE LOCKED AT ALL TIMES WHEN THE ELEVATOR IS MOVING 9 of 14 5 OPERATING THE ELEVATOR FROM THE CAB CONTROLS Automatic Operation 1 2 Insert the key if equipped into the switch in the Cab Operating Panel Turn the key to the ON position Press a Floor Landing button once and release The elevator automatically travels to and stops at the Floor Landing Turn the key if equipped to the OFF position and remove the key Unlock the wheelchair wheels and exit the cab if ap
7. er the dealer or yourself must keep any service and or maintenance records in the Maintenance Record section of this manual WARRANTY Ensure your Savaria Concord Dealer provides you with a copy of the manufacturer s limited parts warranty and documentation relating to any Dealer labour warranty FOR OWNER S RECORDS Customer Name Installing Dealer Dealer s Telephone Number Date Installed Serial Job Number 2 of 14 10 75 SAVARIA LIES concorb ECLIPSE RESIDENTIAL ELEVATOR OWNER S MANUAL TABLE OF CONTENTS GENERAL SPECIFICATIONS STANDARD FEATURES OPTIONAL FEATURES OPERATING THE ELEVATOR FROM THE LANDING CONTROLS OPERATING THE ELEVATOR FROM THE CAB CONTROLS POWER FAILURE AND EMERGENCY LOWERING EMERGENCY LIGHT MANUAL LOWERING MAINTENANCE AND INSPECTION CHECKS MAINTENANCE RECORD 3 of 14 10 11 11 12 13 14 1 Load capacity Rated speed Power supply circuit supplied by others Lighting supply circuit supplied by others Drive system Temperature operating range Cab sizes Cab panel and finish Maximum travel Control system Levels and openings Pit depth requirement Minimum overhead clearance Hall station and control panel finish Standard features GENERAL SPECIFICATIONS ECLIPSE RESIDENTIAL ELEVATOR 750 Ibs 340 kg 950 Ibs 431 kg 1000 Ibs 454 kg 40 feet per minute 0 20 mps standard 208 volt 230 volt single phase 60 Hz
8. n calm and to stay well back from the door of the elevator Ease their concern by telling them your intentions 2 Turn the Main Disconnect Switch to the OFF position 3 Locate the Motor Access Door insert the Manual Hand Crank onto the motor shaft and crank the elevator to the next lowest level 4 Use the Emergency Key to open the elevator door 5 To exit the cab open the lower landing door and assist the passenger s 12 of 14 9 MAINTENANCE AND INSPECTION CHECKS Regular maintenance keeps the Eclipse in proper operating condition Please remember as the owner of this elevator you are responsible to ensure that maintenance and upkeep occurs on a consistent and regular basis To ensure the continual proper operating condition of your unit have a technician inspect the following items and if necessary service the elevator every six 6 months The elevator may require additional inspections depending on usage 1 Tighten all rail and cab fastening bolts 2 Lubricate the door hinges and adjust the door closure if required 3 Lubricate the rails with light grease such as white lithium 4 Inspect the travelling cable for wear Replace if any cuts or damage to the jacket are evident 5 Replace the batteries inside the control panel as indicated on the battery label To perform maintenance to the Kiklock if equipped call your Authorized Savaria Concord Dealer 13 of 14 10 MAI
9. plicable NOTE If the cab is equipped with a gate the gate must be closed after exiting the cab If the gate is left open all controls will remain inoperable An entry and exit timer allows approximately nine seconds before the hall buttons become operational This delay allows time for a person to enter exit the cab 10 of 14 6 POWER FAILURE AND EMERGENCY LOWERING In the event of a power failure the elevator includes a Battery Back Up system that allows the user to lower the elevator from inside of the cab itself this device operates on batteries and activates only if a main power supply failure occurs The following steps describe this operational sequence 1 For elevators with automatic operation press any Floor Landing button below the floor where the elevator currently rests 2 Upon arrival at the floor the landing door automatically unlocks 3 If the door includes an automatic gate the gate opens 4 Remove the key open the manual gate if equipped and exit the cab 7 EMERGENCY LIGHT In the event of a main power failure the emergency cab lights automatically illuminate 11 of 14 8 MANUAL LOWERING In the event of a power failure batteries lower the cab to the next level and open the doors Should the batteries fail use the telephone to call for help A technician can use the Manual Hand Crank to lower the elevator 1 Instruct the person s in the elevator to remai
10. ts cab movement unless the door gate is in the shut position with the lock in place If the door gate is not completely shut the cab does not Figure2 Hall Call Station move 10 Emergency Battery Operation In the event of a building power failure the door gate system includes a temporary power back up system to continue the opening operation a number of times Upon resuming normal building power the back up system turns OFF and automatically recharges 7 of 14 3 OPTIONAL FEATURES Automatic Door Opener a Press the Landing Hall Call button to call the elevator The entrance door opens automatically once the elevator stops at the landing b Press the Remote Control if equipped to open the entrance door once the elevator stops at the landing c Push n Go allows the entrance door to open automatically with a slight push to the door itself The door timer is inoperative when this feature is active Automatic Gate Opener a Press the Landing Hall Call button to call the elevator The Gate opens automatically once the elevator stops at the landing and the entrance door is fully open b Manually open the entrance door The Gate opens automatically once the entrance door is fully open NOTE Ifthe cab is equipped with a gate the gate must be closed after exiting the cab If the gate is left open all controls will remain inoperable An entry and exit timer allows approximately nine seconds b
Download Pdf Manuals
Related Search
Related Contents
Untitled - Acces Diffusion Philips InStyle Spot light 69072/31/16 Sunbeam Scale HAB979 User's Manual HP Insight Dynamics 6.0 スタートガイド BRILLO-SILL My Document - AASHTOWare Bridge Management Monster Cable iCarPlay Installation manual / Manual de instalación / Manual de - Isakos-Soft Medisoft 17 User Manual Origin Storage 320GB Copyright © All rights reserved.