Home
Manual DGT
Contents
1. 19 BA MULTISCALE REPEATER pa pter da 20 8 5 ALIBI MEMORY ALIBI tix abe page 21 OO SINGLE SCALE REPEATER c teet a lated rene page 24 8 7 DISPLAY WITH SENSITIVITY TIMES 10 VIS acne diet ipd d EB Oe Id VS page 25 8 8 HOLD FREEZING OF THE WEIGHT ON THE DISPLAY hLd sn page 25 8 9 PEAK DETECTION OF WEIGHT PEAKS PEAK a aiat eite ta fuccus page 25 8 10 HORIZONTAL TOTALIZER SUM OF LOTS acces Uter thou dicted eles page 26 8 11 VERTICAL TOTALIZER SUM BY FORMULA tot S ntn page 28 8 12 COUNTING COUN som page 28 8 13 SIMULTANEOUS TRANSMITTER OF THE CHANNEL VALUE tYPE trAnSM ses page 31 9 SET POINT FUNCTIONS be aede page 32 10 MESSAGES OF INSTRUMENT WHILE IN USE eene nnne nnne tenete nennen page 37 ITPRINT EXAMPLES nores at ial un dicun d dtc em page 38 DECLARATION OF CONFORMITY cate tbe a RC page 39 WARRANTY AND AUTHORISED ASSISTANCE 1 nnne nrntnnnnenens page 39 DGT DGT60 DGTQ 1 INTRODUCTION The purpose of this man
2. Figure 9 2 Diagram showing the output functioning with active hysteresis in which X indicates the output number IMPORTANT the weight thresholds set with the PRINT key are common to all the connected scales therefore it is not possible to have different thresholds for different scales The value takes on the unit of measure and the decimals of the selected channel for example if one sets 1000 one will have the following set point values Channel Unit of Measure Decimals Set Point Value 1 kg 3 1 000 kg 2 g 0 1000 g 3 kg 2 10 00 kg 4 g 1 100 0 g 2 nEt Set point on NET WEIGHT By selecting this functioning mode one enables in the normal scale status the function of the output on the NET weight the SET POINTS and the specifications are entered the same way as for the functioning on the gross weight but it s possible to set the functioning of the set points on the negative weight FUNCTIONING WITH HYSTERESIS rL iSt HYSTERESIS parameter set at iSt on Functioning on negative weight SiGn parameter set at PoSit The specifications are the same for the functioning mode on the gross weight Functioning on negative weight SiGn parameter set at nEGAt By selecting the functioning mode on the negative weight one enables the output function on the NEGATIVE WEIGHT one enters two NEGATIVE SET POINTS for each output a DISABLING one which when the net weight is greater than it the output is disabled an ENABLING one which when the
3. SCALE CAPACITY FUNCTIONING 100kg All the tare functions are disabled The SEMIAUTOMATIC TARE value can not be modified with a gt 100kg manual tare The manual tare can be entered or modified only with an UNLOADED scale With approved instrument the d SALE step is not displayed 7 4 AUTO POWER OFF FUNCTION It is possible to automatically turn off the indicator from 1 to 255 minutes or disable it the auto power off takes place when with unloaded scale the weight has not been moved or a key has not been pressed for the time set the display shows the oFF blinking message after this the indicator turns off For the setting follow the procedures below Tum on the scale press the TARE key while the firmware version is displayed the display shows the tYPE menu Select F ModE by pressing once the ZERO key and press PRINT to enter in the menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the AutoFF parameter Press PRINT to enter the parameter With the ZERO or TARE keys select the possible options diSAb auto switch off disabled EnAb auto switch off enabled Confirm with PRINT if EnAb has been selected one will be asked to enter the number of minutes after which the indicator should turn off enter a number between 1 and 255 using the MODE key to select the digit to be modified and ZERO TARE to decrease increa
4. 06760 DGTQ 23 K Pr PRINT KEY By selecting this functioning mode in the normal scale status the output is enabled for about 2 seconds when the PRINT key is pressed 25 K Mod MODE KEY By selecting this functioning mode in the normal scale status the output is enabled for about 2 seconds when the MODE key is pressed 26 K C C KEY By selecting this functioning mode in the normal scale status the output is enabled for about 2 seconds when the C ON OFF key is pressed 21 K ZEr ZERO KEY By selecting this functioning mode in the normal scale status the output is enabled for about 2 seconds when the ZERO key is pressed 28 K tAr TARE KEY By selecting this functioning mode in the normal scale status the output is enabled for about 2 seconds when the TARE key is pressed 29 Err ERROR INDICATION By selecting this functioning mode in the normal scale status the output is enabled on the invalid weight OVERLOAD UNDERLOAD is enabled or without the signal coming from the cell DISCONNECTED CELL NOTES Inthe inD Ch and TrAnSM mode the output is enabled only when the condition takes place on the selected channel In the dEP Ch modes the output is enabled when the condition takes place on any of the set channels 36 DGT 06760 DGTQ 10 INSTRUMENT MESSAGES WHILE IN USE MESSAGE DESCRIPTION AL Err It i
5. GROSS 3 000 kg TARE 1 000 kg NET 2 000 kg 00000002 WEIGHING NR 00000002 TOTAL NET 2 862 kg TICKET NR 2 24 08 06 16 54 10 Totalizer Mode GROSS HOLD 3 326 kg TARE HOLD 1 364kg NET HOLD 1 926 kg TICKET NR 1 24 08 06 16 54 10 Hold Mode SCALE 1 SCALE 2 SCALE 3 SCALE4 10 000 kg SUM 19 000 kg TICKET NR 1 16 08 06 11 56 10 0 000 kg 4 000 kg 5 000 kg Master Mode Sum mode 38 DGT DGT60 DGTQ HEADING 1 HEADING 2 HEADING 3 HEADING 4 GROSS 8 000 kg TARE 3 000 kg NET 5 000 kg TICKET NR 1 24 08 06 16 54 10 Standard Weight Indicator Mode UISS Std ntgS GROSS 1 000 kg TARE 0 500 kg NET 0 500 kg PCS 100 APW 0 005 kg TICKET NR 2 24 08 06 16 54 10 Piece Counting Mode GROSS PEAK TARE PEAK 0 000 kg NET 1 500 kg TICKET NR 1 24 08 06 16 54 10 1 500 kg Peak Mode DGT DGT60 DGTQ DECLARATION OF CONFORMITY This device conforms to the essential standards and norms relative to the applicable European regulations The Declaration of Conformity is available in the web site www vetek com ONE YEAR WARRANTY The ONE YEAR warranty period begins on the day the instrument is delivered It includes spare parts and labour repair at no charge if the INSTRUMENT IS RETURNED prepaid to the DEALER S PLACE OF BUSINESS Warranty covers all defects NOT attributable to the Customer such as improper use and NOT caused during transport If on site service is requested or
6. Press ZERO or TARE various times until the chosen quantity is displayed 4 From the container take off the same number of pieces and press PRINT to confirm The display shows SAMPL while the indicator calculates the Average Piece Weight The display shows in negative the quantity extracted 6 Continue the counting in extraction Er Mot ERROR DUE TO WEIGHT INSTABILITY DURING THE SAMPLING It may happen that during the sampling phase the weight is unstable and therefore it is not possible to correctly calculate the APW The Er Mot is shown remaining for about three seconds One should therefore repeat the sampling operation MINIMUM WEIGHT OF THE SAMPLE It is advisable to use a reference quantity equal or greater than 0 196 of the scale capacity In any case the weight of the reference quantity should not create an APW lower than the two internal points of the converter intrinsic limit of the instrument if this condition takes place during the sampling the display will indicate for an instant Error and the quantity put on the plate will not be accepted One should therefore use a higher reference quantity 29 DGT DGT60 DGTQ DISPLAY AND MODIFICATION OF AVERAGE PIECE WEIGHT APW It is possible to view or enter with the keyboard a known APW to speed up the reference operations Press the PRINT key at length f one has configured the functioning of a output upon reaching a set point one accesses a submenu in which
7. TO BE USED IN TESTING DURING THE CALIBRATION Simple display functioning mode with the function of switching the weight for display with sensitivity increased 10 times FUNCTIONING By pressing the MODE key one switches from the weight display with normal sensitivity to a sensitivity ten times greater in fact one will note that the last digit on the right of the display will have a sensitivity equal to the scale s division divided by 10 The printout and the change of channel can only be done when the indicator has the standard sensitivity By pressing the PRINT key at length one directly enters the SETPOINT INPUT Menu see section 9 NOTE In case the instrument is LEGAL FOR TRADE when MODE is pressed the sensitivity times 10 is displayed for five seconds after which the instrument returns to standard weight displaying Furthermore with the SEtuP gt gt d SALE parameter set at YES TECH MAN REF this displaying is possible only with capacities over or equal 100 kg 220 Ib 8 8 HOLD FREEZING THE WEIGHT ON THE DISPLAY hLd Simple display functioning mode with the function of freezing the weight shown on the display FUNCTIONING pressing MODE the value of the weight is held on the display and the display shows HoLd alternately with the weight held value every 5 sec Torelease the weight value on the display press MODE key again By pressing the PRINT key at length one directly enters the SETPOINT INPUT Me
8. channel to be displayed when the instrument is configured in the Independent Channels Mode see Section 4 Calibration TECH MAN REF using the MODE key By pressing the MODE key at length The Chari message appears for a few instants e of channel used until that moment is displayed For example if channel 1 Ch 1 appears e Select the number of channel to be displayed using the ZERO or TARE keys For example if the channels 1 2 and 3 are configured the items Ch 1 Ch 2 Ch 3 will appear e Confirm the choice by pressing the PRINT key DGT DGT60 DGTQ 7 12 REMOTE CONTROL OPTIONAL JUST WITH DGT60 MODEL Just with the DGT60 model with the remote control it is possible to remotely use the ZERO TARE MODE PRINT keys or just the TARE key To choose which type of functioning follow the below procedure on the scale press the TARE key while the firmware version is displayed the display shows the typE menu Press ZERO many times to scroll forwards through the parameters or TARE to scroll backwards until one finds the FModE parameter Press PRINT to enter the menu Press ZERO many times to scroll forwards through the parameters or TARE to scroll backwards until one finds the irConF parameter Press PRINT to enter the parameter With the ZERO or TARE keys select the possible options ir no disabled remote control ir 1 all the remote control keys function as th
9. functioning of a output upon reaching a set point one accesses a submenu in which it s possible to choose which parameter to modify select InP StP see section 9 By pressing the MODE key f there is NOT a reference one sets the REFERENCE VALUE see COUNTING PROCEDURE described in the following paragraph If there is a reference one alternates the display of NR OF PIECES WEIGHT ON THE SCALE By pressing the C ON OFF key One CANCELS the REFERENCE previously set the display shows for an instant CLEAR if there is no valid reference to be cancelled the message does not appear With the following pressing of the MODE key equivalent to a first pressing of the key its possible to set a NEW REFERENCE 28 DGT 06760 DGTQ COUNTING PROCEDURE The operations to be carried out are the following 1 Place the empty container on the scale and press TARE to tare it 2 Check that the zero is on the display and press the MODE button the counting function activates 3 The display suggests a REFERENCE QUANTITY The possible options are 5 10 20 30 40 50 60 75 100 200 4 Press ZERO or TARE the number of times needed to reach the desired sample size 5 Put the quantity of pieces chosen for the SAMPLE on the scale and press ENTER PRINT to confirm or C ON OFF to cancel the operation and return to weighing APW calculation 6 Press PRINT the display will show SAMPL the indicator will calculate the Average Pi
10. if at start up a weight within 10 of the capacity is detected it will be zeroed if the weight is not within this tolerance with a non approved instrument the display shows the present weight after a few instants while with an approved instrument ZEro is shown continuously on the display until the weight is made to re enter within this tolerance the auto zero function at start up may be disabled in the set up environment only with non approved instrument see SEtuP ConFiG Param Auto 0 TECH MAN REF By pressing the ZERO key for an instant while the version is shown in the LED display the indicator will show the following in this order 09 01 in which 09 indicates the type of the instrument 01 indicates the metrological software version XX YY ZZ is the installed software version dGt60 or dGtq is the name of the installed software CLoCK if there is the optional board with date and time n Ch X number of the configured channels if equal to 2 3 or 4 XXX XXX capacity and division of channel 1 NOTE the display of the other information is described in section 7 10 DISPLAY OF METRIC DATA inFO After this the instrument executes a countdown self check and preheating and finally hi rES is displayed in case of non approved instrument or LEGAL and the gravity acceleration value of the area of use in case of approved instrument TO PUT THE INSTRUMENT IN STANDBY keep the C ON OFF key pressed unt
11. of a output upon reaching a set point has been configured one enters a submenu in which it s possible to choose which parameter to modify select PIC tIM The message tP appears on the display followed by a number which corresponds to the minimum time length of the impulse expressed in hundredths of seconds By pressing ZERO or TARE the following settable values are proposed 1 2 3 4 5 10 20 30 40 50 60 75 100 and 127 press PRINT to confirm the desired value the indicator will return to weighing TABLE OF OPERATING PARAMETERS IN PEAK MODE LENGTH SAMPLINGS PER SECOND ACQUIRED VALUES MEDIATED VALUES 1 400 1 1 2 200 1 1 3 100 1 1 4 100 4 2 9 50 4 2 10 25 4 2 20 12 4 2 50 6 4 2 100 6 8 2 127 6 12 2 8 10 HORIZONTAL TOTALIZER Sum of lots tot o Tot Mod TYPE OF TOTALISATION NORMAL FAST AUTOMATIC Once the totalizer operating mode is selected both horizontal and vertical one is asked to set the type of totalization normal t norM fast t FASt or automatic Auto with ZERO or TARE one changes the parameter with PRINT one confirms n the normal totalisation for each accumulation operation there is the display of the weigh number and the net weight total before the printing of the data in the fast one just the display of the tot message appears on the display before the printing of the data n the automatic one there is the automatic acqu
12. seconds the message SCA n appears indicating the meaning of the shown data and in which n is the number of the active scale in that moment By pressing at length the MODE key the sum of the weight on all the scales is shown the display shows SUM and then the sum of the net weight on all the scales In the display of the sum the SUM message appears about every 10 seconds and it indicates that the sum of the weights present on the scales is being displayed The reference unit of measure is that of the connected SLAVE with the lowest address if the other weights have different units of measure these are automatically converted If the sum of the weights is greater than 999999 the segments in the upper part of the display are turned on If the sum of the weights is less than 99999 the segments in the lower part of the display are turned on If the sum of weights is not valid because one or more slaves is in under load or overload the segments in the central part of the display are turned on By pressing the ZERO TARE PRINT and C ON OFF keys the functionality of the key pressed in the selected slave is transmitted 20 DGT 06760 DGTQ EXECUTION OF THE PRINTOUTS If there is a printer on the master it s possible to execute on it the printouts configured in the active slave In order to do this in the master one should set the transmission mode for the desired printer this setting is made in the SEtuP gt gt SEriA
13. this allows to switch the displayed channel of the instrument if configured in the Independent Channels mode or IND CH In NUMERIC INPUT selects the digit to be modified from left to right Executes a SPECIFIC FUNCTION of the functioning mode which has been previously set in the set up environment In NUMERIC INPUT confirms the entry made In SETUP allows to enter a step or to confirm a parameter inside a step Executes a PRINTOUT or transmission of the data from the serial port dedicated to the printer PRINT i ON STANDBY of the instrument In NUMERIC INPUT quickly clears the present value ON Stb In SETUP allows to exit a step without confirming the modification made Visualisation of Metric information of the scale Capacity Division Minimum weigh for each configured range Gravitational Acceleration Value Number of configured Channels DGT 06760 DGTQ 7 BASIC FUNCTIONS 7 1 SCALE ZERO By pressing the ZERO key it is possible to zero a gross weight value which is within 2 of the capacity after the zeroing the display shows 0 weight and the relative pilot lights turn on 7 2 TARE OPERATIONS SEMIAUTOMATIC TARE By pressing the TARE key any weight value present on the display is tared the display shows tArE for an instant and then 0 net weight the relative keys turn on NOTE The semiautomatic tare will be acquired only if the weight is A
14. to the lt ESC gt II PIDD lt STX gt command ESC II PIDDSS B LLLLLLLLLLUU YYTTTTTTTTTTUU ID NO dd mm yybbhh mm ss NO DATE TIME lt STX gt In which II 485 address only when transmitting in 485 mode SS OL weight in overload or UL weight in under load or ST stable weight or US unstable weight or TL TILT input closed comma character ASCII decimal 44 B scale number from 1 to 4 LLLLLLLLLL gross weight on 10 digits UU unit of measure 2 spaces in the case of null tare or semiautomatic tare PT in case of manual tare tare on 10 digits ID XXXX YYYYYY which XXXXX is the rewriting number 5 digits from 00000 to 00255 and YYYYYY is the weigh number 6 digits from 000000 t0 131072 dd mm yy Date in the dd mm yy format only with PIDD command bb 2 space characters ascii decimal 32 character only with PIDD command hh mm ss Now in the hh mm ss format only with PIDD command In the case in which the gross weight is negative or unstable the weight is transmitted but not the ID NO is in its place In these cases there is no storage in the alibi memory If the ALIBI MEMORY board is not detected only the weight and not the date and time is sent in response to the REXD command and in its place there is NO DATE TIME 23 DGT DGT60 DGTQ WEIGH READING Command IIJALRDXXXXX YYYYYY CR CRLF gt In which Il 485 address only when transmitti
15. use the instrument as a counting scale after making a reference operation described in the Counting Procedure which consists in linking a sample weight to a specific quantity of pieces REFERENCE value calculating in this way the Average Piece Weight APW Upon the selection of the functioning mode in the SET UP ENVIRONMENT F Mode gt gt Funct gt gt Coun the setting of some parameters is requested uM APW Unit of Measure of the average piece weight APW Press PRINT to enter in the step With the ZERO or TARE keys select the unit of measure g kg t Lb Confirm with PRINT Press many times the C ON OFF key until the display shows the message SAVE Press PRINT to confirm the changes made or another key to not save Independently from the unit of measure selected the APW has always three fixed decimals WAit t sampling interval Setting of the sampling time in seconds with a decimal greater is the time set and more precise will the calculated APW be e Press PRINT to enter the step Set the desired time Confirm with PRINT Press many times the C ON OFF key until the display shows the message SAVE Press ENTER PRINT to confirm the changes made or another key to not save FUNCTIONING By pressing PRINT at length it s possible enter the known APW value see DISPLAY AND MODIFICATION OF AVERAGE PIECE WEIGHT described later on Seta SET POINT If one has configured the
16. ARE FUNCTION AUTO SWITCH OFF FUNCTION LOAD CELL POWER SUPPLY LOAD CELL CONNECTION CASE SERIAL OUTPUTS OUTPUTS INPUTS 3 SYMBOLS 12 24 Vdc DGT4 DGT60 DGTQ 100 mA a 12 V 70 mA a 24 V DGT4AN DGTQAN 185 mA a 12 V 90 mA a 24 V DGT4PB DGTQPB 410 12V From 10 to 40 C 10000e 3 x 3000e for legal weighing expandable up to 800 000 for internal use with minimum signal coming from a 1 6mV V cell 200 conv sec with automatic selection 0 3 uV approved instrument 0 03 uV non approved instrument 1 500 000 points with input signal equal to 3mV V 6 digits h 13 mm 6 status indicator LEDs Waterproof 5 key keyboard Subtractive possible on the entire capacity Programmable from 1 to 255 minutes or disinserted 5Vdc 5 120mA up to 8 cells of 350 Ohm each 6 wires CELL1 with Remote Sense 4 wires CELLS 2 3 4 DGT model Plastic console suitable for mounting on DIN bar or on the wall DGT60 model STAINLESS STEEL case with fixed bracket standard fitting or STFR adjustable bracket OPTIONAL for mounting or on the wall DGTQ model Case for panel mounting in self extinguishing NORYL UL 94 VO according to DIN 43700 norms color black 1 RS485 bidirectional port configurable for connection to a PC PLC or WEIGHT REPEATER DGT4 DGT4AN DGT60 DGTQ and DGTQAN versions 1 RS232 bidirectional port configurable for connection to a printer 1 PROFIBUS port DGT4PB and DGTQPB versions 2 photom
17. E For one s convenience it is also possible to choose that the tare value cancels itself automatically each time that the scale is unloaded UNLOCKED TARE or disable the tare functions With the UNLOCKED tare Incase of SEMIAUTOMATIC TARE the net weight before unloading the scale may also be 0 n case of MANUAL TARE the net weight before unloading the scale must be greater than 2 divisions and stable DGT DGT60 DGTQ To set the type of tare Turn on the indicator press the TARE key while the firmware version is displayed the display shows the tYPE menu Select F ModE by pressing once the ZERO key and press PRINT to enter in the menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the tArE t parameter Press PRINT to enter the parameter With the ZERO or TARE keys select the possible options LoCK locked tare unLoCK unlocked tare diSAb disabled tare Confirm with PRINT Press the C ON OFF key many times until the display shows the message SAVE Press PRINT to confirm the changes made or another key for not saving The indicator stores the last selection made also after it is turned off 7 3 LIMITATION OF THE TARE FUNCTIONS With approved instrument it is possible to limit the tare functions selecting SEtuP gt gt d SALE gt gt yES TECH MAN REF the tare operations will have the following specifications
18. EIGHT 4 It turns on when the SPECIFIC FUNCTION of the instrument is ACTIVE which is set in the FMODE gt gt FunCt parameter a key is pressed It turns off when the SPECIFIC FUNCTION of the instrument IS DISABLED with an active function a key is pressed When blinking it means that the instrument function is active for 5 seconds 5 v If instrument in dual range and approved one s within the 1st weighing range wf In the other cases It shows the activation of the 1st OUTPUT 5 1 6 T If instrument dual range and approved one s within the 274 weighing range w2 In the other cases It shows the activation of the 274 OUTPUT Sp2 7 Sensor for the reception of the infrared signal standard fitting only for the DGT60 model DGT DGT60 DGTQ 6 5 FUNCTIONS OF THE KEYS DGT and DGT60 KEY FUNCTION DGT60 KEY Clears the displayed gross weight if included within 2 of the total capacity Cancels the negative tare value In NUMERIC INPUT decreases the digit to be modified ZERO With Brief pressing executes the semiautomatic tare With Long pressing allows to enter a manual tare from the keyboard Cancels the negative tare value In NUMERIC INPUT increases the digit to be modified TARE MODE Executes a SPECIFIC FUNCTION of the functioning mode which has been previously set in the set up environment By Pressing at length
19. ERATIONS a e page 12 7 3 LIMITATION OF THE TARE FUNGTIONS aet reti hehe 13 PA AUTO POWER OFF FUNCTION cioe tb URDU oi boni der lup le bob pto page 13 7 5 MULTIRANGE FUNCTIONING for legal for trade approved instruments page 14 7 6 DATE TIME ADJUSTMENT OPTIONAL 5 etre eant page 14 7 1 SCREEN SAVER FUNCTION OPTIONAL ion eee nae eee page 14 1 8 EXECUTION OF THE PRINTOUTS tiec ende Neto dead entes page 15 7 9 REENABLING OF THE PRINTOUTS AND THE INDICATOR FUNCTIONS een page 15 7 10 VISUALISATION OF METRIC DATA inFO laii e abet eo een page 16 7 11 SELECTION THE CHANNEL TO BE DISPERAYED siet roo b rb eb tot bis bres page 16 7 12 FUNCTIONING WITH REMOTE CONTROL OPTIONAL JUST WITH DGT60 MODEL page 17 8 SELECTABLE FUNCTIONING MODES traten rtt page 17 8 1 UNIT OF MEASURE CONVERSION 5 utu aS eu 18 65 te bte eie qp scanners 19 ero
20. L gt gt CoMPrn gt gt PrModE parameter TECH MAN REF The selection of this parameter excludes the printouts on the active slave On the master it s also possible to configure a printout which may be used when the sum of the weights on all the scales is displayed In order to configure this format refer to section 8 PROGRAMMING OF THE PRINTOUTS TECH MAN REF WARNING out the weight repeater function it is sufficient that just one SLAVE instrument in the system be turned on When turned on the MASTER places itself automatically on the first turned on SLAVE lowest 485 address if all the instruments are off or if the radio signal does not reach the MASTER on the same display the ECo n message is displayed in which n is the address number of the SLAVE with which one is trying to communicate lf there are various slaves in no case is it possible to transmit the functionality of the MODE key to the active slave carry out the sum function it is necessary to have a connection with at least two SLAVES Inthe sum mode it isn t possible to transmit the functionality of the ZERO TARE and PRINT keys to the SLAVES If the connection is lost with the SLAVE which is acting as a repeater the MASTER will try to reconnect it if after about a second this does not happen it connects with the following SLAVE connection is lost with SLAVE in the sum mode the MASTER tries to reconnect it if this happens
21. Mod gt norM t FASt t Auto Max tot gt tots totMod gt norM t FASt t Auto Max tot gt Coun gt uM APW G Lb t kG Max tot DGT 06760 DGTQ To set the operating mode carry out the following procedures on the scale press the TARE key while the firmware version is displayed the display shows the menu Select F ModE by pressing once the ZERO key and press PRINT to enter in the menu the display shows the FunCt menu Press PRINT to enter the parameter With the ZERO or TARE keys select the possible options Std Unit of measure conversion ntGS net weight gross weight conversion inout output weighing MAStr Multiscale repeater ALibi Alibi memory rEPE Single scale repeater UiSS Sensitivity times ten hLd Freezing of the weight on the display PEAK Peak detector tot o Horizontal totalizer tot S Vertical totalizer Coun Counting Confirm with PRINT if one has selected the inout MAStEr tot or tot 5 or Coun mode will be asked to select another operating parameter refer to the specific functioning mode section for the relative description The instrument automatically goes to the following step Press many times the C ON OFF key until the display shows the message SAVE Press PRINT to confirm the changes made or another key to not save NOTE Once the functioning mode is selected and there is a printer the standard printouts
22. NPUT and OUTPUT with unit of measure OUTPUT NET gt gt if WEIGH 1 lt WEIGH 2 Difference without sign between INPUT and OUTPUT with unit of measure DGT 06760 DGTQ FUNCTIONING Through the MODE key of the indicator one acquires the first weight on the display is shown 1 By pressing again the MODE key of the indicator one acquires the second weight and on the display is shown 2 When the acquisition of the second weight is made the printing of the data is commanded It is possible to interrupt the weighing cycle by pressing the C ON OFF key after the acquisition of the first weight On the display the message CLEAr Press PRINT to confirm the cancelling of the first acquired weight or another key to not confirm By pressing PRINT at length one enters directly into the INPUT menu of the SET POINTS see section 9 NOTES weight is acquired if With a NON APPROVED scale one has a STABLE weight and GREATER than 0 With an APPROVED scale one has a STABLE weight and GREATER than 20 divisions If the setting of the rEACt parameter in the set up environment has been respected passage by zero of the weight instability or always see the REENABLING OF THE PRINTOUTS AND THE INDICATOR FUNCTIONS section 8 4 MULTISCALE REPEATER MAStr The system is made up of one or more indicators up to 4 called SLAVES connected to one or more weighing systems which communicate with another indicator ca
23. OINT value the pressing of the PRINT key at length does not allow to access the configuration of the set points With the indicator off or in standby the outputs are normally open no The DISABLING SET POINT must be equal or less than the ENABLING one if in the DISABLING SET POINT a value is entered and confirmed which is greater than the ENABLING one the indicator will set the set point at 0 until a valid value is entered If in the ENABLING SET POINT one enters a confirms a value lower than the DISABLING one the value will be accepted but the DISABLING SET POINT will be put at 0 The 0 value is valid on both the set point values The check on the weight remains active on this value also while modifying the SET POIINT until the new value is confirmed If the weight is not valid the outputs will not be disabled At start up the outputs are managed from when the weight is displayed and these take on the configuration set in the set up environment These are not managed inside the set up The tare operations are active The length of the enabling impulse of the outputs for the keys linked to these is about 2 seconds PRINT MODE C ZERO TARE keys The outputs are enabled by pressing the key if the key pressing time is greater than 2 seconds the output is disabled after 2 seconds and remains disabled until the following pressing of the key 33 DGT DGT60 DGTQ OUTPUT X STATUS ENABLED DISABLED S X OFF S X on GROSS WEIGHT
24. SEtuP gt gt SeriAL gt gt CoM Pc step and section 6 4 TRANSMISSION MODES OF THE SERIAL PORTS TECH MAN REF If rEPE 6 communication protocol has been set in the REPEATER one will need to set the rEPE 6 communication protocol in the TRANSMITTER on the desired port If W rEPE communication protocol has been set in the REPEATER one will need to set the protocol of the continuous weight transmission on the desired port of the TRANSMITTER For further configuration details refer to the technical manual of the connected indicator FUNCTIONING When the indicator is turned on it waits for the data if it does not receive a correct communication string the communication parameters are wrong or it does not receive any character it remains in the test condition in other words with all the central segments of the display turned on When the serial string of the connected instrument is identified the indicator repeats the data of the display or the weight string of the instrument to which it is connected 24 DGT DGT60 DGTQ CAREFUL The keys pressed in the REPEATER are not repeated on the TRANSMITTER and vice versa The indicator acts as a simple weight repeater only the C ON OFF key is enabled for turning on off In this functioning mode for the printer port only the rEPE6 transmission mode is enabled see section 6 4 TRANSMISSION MODES OF THE SERIAL PORTS TECH MAN REF 8 7 DISPLAY WITH SENSITIVITY X 10 VISS
25. T LEAST A DIVISION STABLE instability led off and VALID in other words the OVERLOAD condition should not be created MANUAL TARE FROM KEYBOARD Press TARE for a few seconds the display shows tM and then 000000 Enter the desired value using the following keys ZERO decreases the blinking digit TARE increases the blinking digit MODE selects the digit to be modified blinking the scrolling of the digits takes place from left to right C ON OFF if pressed for an instant it quickly zeros the present value if pressed at length it allows to return to weighing without saving the changes made Confirm with the PRINT key the value will be subtracted from the weight present on the plate and the relative pilot lights will turn on If the entered value is not a multiple of the scale s minimum division it will be rounded off CANCELLING A TARE One can manually cancel the tare value in different ways unload the scale and press the TARE or ZERO key carry out the tares in deduction partially unloading the scale and pressing TARE to zero the display press C ON OFF without unloading the scale enter a manual tare equal to 0 NOTE it is possible to automatically cancel the tare value by doing the following SELECTION OF LOCKED UNLOCKED DISABLED TARE Normally when a tare value is entered automatic manual or from storage by unloading the scale plate the display shows the tare value with a negative sign LOCKED TAR
26. VETEK Scandinavia s biggest webshop for scales WEIGHT INDICATORS 29525999 User Manud DGT_DGT60_DGTQ_05_07 04_UK_U DGT 06760 DGTQ INDEX TINTRODUCTION TE page 2 2 MAIN TECHNICAL FEATURES o red s ac Reg edet rise page 3 39YMBOES teaser ern tt atte du DI UE NIE Lx M lit page 3 A INSTALLATION ME eem page 4 4 1 DGELCASEANDDIMENSIONS stri rrt tee pede eto page 4 4 2 DGT60 CASE AND DIMENSIONS pa hoa ERR Tot page 5 4 3 DGTQ CASE AND DIMENSIONS estos totius boite 6 tentes De onde 7 6 FRONT PANEL KEYS AND INDICATORS 2 4 2041 11 tenente tenete page 8 8 6 2 DG OUINOCS 8 6 9 DOTO fmogdel o od DI datu M E page 9 64 FUNCTION OF EME INDICATORS be ae teri page 10 56 5 FUNGTION OF THE KEYS eae a tac hater ce page 11 T BASIG FUNCTIONS m page 12 TAPS OALE ZERO nerne page 12 1 2 TARE OP
27. alisation with the normal totalizer one can temporarily view on the display the number of weighs carried out and the PARTIAL NET TOTAL accumulated until that moment Subtotal if the accumulated digit is more than 5 digits the visualisation takes place in two stages with the fast totalizer the no 0 UnS error message is displayed NOTE If the gross or net weight is equal to zero with the normal totalizer the indicator displays the accumulated total while with the fast totalisation the GroS Er error message is displayed TOTALISATION WITH PRINTING If the presence of a printer has been configured upon each pressing of MODE one prints the data programmed in step SEtuP gt gt SEriAL gt gt CoM Prn gt gt Pr ConF of the set up environment TECH MAN REF for example Weigh number GROSS weight weight weight PRINTING AND ZEROING OF THE TOTALS The instrument has two different total levels a partial total and a general total which increase upon each totalisation these may be printed and zeroed independently from each other To print and zero the PARTIAL TOTAL one should press for an instant the PRINT key brief pressing depending on the type of totalisation various messages will be displayed With normal totalisation the number of weighs and the accumulated total will be displayed With fast or automatic totalisation the message totAL will be displayed The number of weighs made and
28. aliser modes in order to print the totalised weight the following must take place the weight must be stable the net weight must be gt of a division with normal or fast totalisation the net weight must be gt of 10 divisions with automatic totalisation The printing is reactivated depending on how the rEACT parameter has been set in the set up environment passage by zero of the NET weight weight instability or always see REENABLING OF THE PRINTOUTS AND OF THE INDICATOR FUNCTIONS section Legal for Trade scale printing In order to be able to print with a legal for trade scale the following conditions must exist the weight must be stable the net weight must be gt the minimum weight minimum of 20 divisions the printing is reactivated depending on how the rEACT parameter has been set in the set up environment passage by zero of the NET weight weight instability or always see REENABLING OF THE PRINTOUTS AND OF THE INDICATOR FUNCTIONS section To configure the printouts go to the PROGRAMMING THE PRINTOUTS section in the technical manual TECH MAN REF Notes The printing is confirmed by the indication on the display of the Print message If the printout is not reenabled the display shows the no 0 unS message With the weight unstable the display shows the unStAb message 7 9 REENABLING THE PRINTOUTS AND THE INDICATOR FUNCTIONS While using the indicator it is possible to incu
29. an be enabled through the serial commands described in the ALIBI mode section 8 5 ALIBI MEMORY section SERIAL COMMANDS and only some serial commands described in section 6 5 TECH MAN REF List of usable commands PID ALRD ALDL VER REXT REXTA READ MVOL RAZF CGCHN ECHO DISP DINT PCOK STAT KEYP KEYR Note the simulation of the pressing of the scale keys through the KEYP and KEYR commands allows to only manage the functions linked to the MODE key 31 DGT DGT60 DGTQ 9 SET POINT FUNCTIONS The indicator is fitted with 2 inputs optoisolator Photocouplers and 2 outputs photomosfet expandable to 6 through option in the DGTQ model whose electric specifications are shown in Section 2 Main Technical Specifications of this manual as well as in the Connection Schemes at the end of the Technical Manual In the outPutS menu of the SET UP SEtuP gt gt outPut TECH MAN REF it is possible to set the functioning mode of each of the two outputs the functioning mode FunC the normal status open or closed no nC the switching condition direct or upon weight stability drCt StbL active hysteresis enabling and disabling set points or not single set point iSt OFF iSt no the sign of the configured set point PoSit nEGAt only for the set point on net weight and set point on pieces functioning modes the output enabling time EnAb tM and the delay time for enabling the output dELAY Spe
30. ate time follow the procedure below Tum on the scale press the TARE key while the firmware version is displayed the display shows the tYPE menu Select F ModE by pressing once the ZERO key and press PRINT to enter in the menu Press ZERO many times to scroll forwards through the parameters or TARE to scroll backwards to find the CLoCK parameter Confirm with PRINT in this order one will be asked to enter the day month year hour and minutes The entry of each parameter must be confirmed with PRINT Press the ON OFF key many times until the message SAVE appears on the display Press PRINT to confirm the changes made or another key to not save NOTE the CLoCK parameter is not displayed if there is no date time option 7 7 SCREEN SAVER FUNCTION OPTIONAL If the indicator is fitted with the date time function it is possible to enable the Screen Saver after a programmable time from 1 to 255 minutes with the scale unloaded the time is shown on the display in the HH MM SS format As soon as a weight variation is detected or a key is pressed the indicator returns to viewing the current weight To set the function on the scale press the TARE key while the firmware version is displayed the display shows the menu Select F ModE by pressing once the ZERO key and press PRINT to enter in the menu Press ZERO many times to scroll forwards through the parameters or TARE t
31. cifically for the Func step the following functioning modes are possible none set point on the gross weight set point on the net weight set point on pieces gross weight at zero net weight at zero weight instability totalisation set point on the pieces total pressing of the KEYS PRINT MODE C ZERO TARA error indication NOTE some of functioning modes of the outputs are relative to the specific functioning modes of the instrument see the following descriptions for the details USER amp TECH MENU SEtuP outPut S The step is displayed in the DGTQ model Figure 9 1 Steps in the SET UP ENVIRONMENT for the OUTPUT SETTINGS If the instrument is in a single range or in non approved dual range The w1 sp1 w2 sp2 leds turn on to indicate respectively the enabling of OUTPUT 1 sp1 and OUTPUT 2 sp2 32 DGT 06760 DGTQ Description of the configurable functionalities for the outputs FunC 0 nonE No Function No functionality is linked to the outputs which therefore are completely inactive 1 GroS Set point on the GROSS WEIGHT Functioing with hysteresis rL iSt HYSTERESIS parameter set at iSt on By selecting this functioning mode one enables the output function on the GROSS weight one enters two SET POINTS for each output a DISABLING one which when the gross weight is below it disables the output a
32. e TARE key or ir 4 the remote control keys functions as ZERO TARE MODE and PRINT Confirm with PRINT Press the C ON OFF key many times until the message SAVE appears on the display Press PRINT to confirm the changes made or another key to not save NOTE The function of the keys with PROLONGED function are not repeatable on the remote control 8 SELECTABLE OPERATING MODES In addition to the STANDARD weighing mode with TARE deduction and transmission of data the indicator can carry out one of the following functions UNIT OF MEASURE CONVERSION NET GROSS SWITCH IN OUT WEIGHING MULTISCALE REPEATER ALIBI MEMORY SINGLE SCALE REPEATER DISPLAY WITH SENSITIVITY X 10 FREEZING OF THE WEIGHT ON THE DISPLAY PEAK DETECTOR HORIZONTAL TOTALIZER VERTICAL TOTALIZER PIECE COUNTING SIMULTANEOUS TRANSMITTER OF THE CHANNEL VALUE Each functioning mode foresees the turning on of various function pilot LEDs described in detail in the sections KEYS AND INDICATORS OF THE FRONT PANEL ONLY TECH MENU USER amp TECH MENU F ModE FunCt Std ntGS gt inout G t 1St 2nd in out gt MAStr nuMSL 01 04 I Alibi p lp ViSS gt gt gt toto gt tot
33. ece Weight APW After a few instants the display will indicate the quantity selected put on the platform 7 Add the rest of the items to count in the container and whose value will appear on the display 8 Unload the scale with the unloaded plate the message PCS 0 will appear on the display The APW will remain stored until the indicator is turned off allowing for the counting of similar pieces without having to repeat the REFERENCE operation 9 By pressing the MODE key one switches from the display of the number of pieces to the display of the net weight and vice versa 10 To carry out a new reference operation Press the C ON OFF key when the instrument displays the number of pieces the message CLEAR will appear to show the cancellation of the REFERENCE value With the following pressing of the MODE key it is possible to set a new REFERENCE value repeating the operations as described from point 3 onwards NOTES If the number of calculated pieces is greater than 999999 the display shows just the first 6 digits on the right By changing the visualisation from 1 channel to the other the reference is not cancelled and the chosen type of visualisation weight or pieces remains with the possibility of switching it by pressing MODE PIECE COUNTING IN EXTRACTION 1 Load a FULL container on the scale and press TARE to tare it 2 Press MODE The display suggests various REFERENCE QUANTITIES 5 10 20 30 40 50 60 75 100 200 3
34. ere is no stored weigh relative to the entered ID the message id appears and one returns to weighing INITIALISATION OF THE ALIBI MEMORY It is possible to cancel all the weighs made initialising the alibi memory this operation can be made directly on the indicator see the parameter SETUP gt gt ini AL of the set up environment TECH MAN REF or through the serial command see SERIAL COMMANDS below NOTES 1016 not possible to just cancel a single weigh initialisation is possible only with a non approved instrument 22 DGT 06760 DGTQ SERIAL COMMANDS Besides the commands described in the 6 5 FORMAT OF THE SERIAL COMMANDS TECH MAN REF in this functioning mode also the commands below are available WEIGH STORAGE Command II PID lt CRLF gt or lt 5 gt lt 5 gt and Il JPIDD lt CRLF gt or lt ESC gt II PIDD lt STX gt in which 1 485 address lt 5 gt 27 ascii decimal character lt 5 gt 2 ascii decimal character Instrument response to the II PID lt CRLF gt command I PIDSS B LLLLLLLLLLUU YYTTTTTTTTTTUU ID NO lt CRLF gt Instrument response to the lt ESC gt II PID lt STX gt command ESC II PIDSS B LLLLLLLLLLUU YYTTTTTTTTTTUU ID NO lt STX gt Response of the instrument to the II PIDD lt CRLF gt command W PIDDSS B LLLLLLLLLLUU YYTTTTTTTTTTUU ID NO dd mm yybbhh mm ss NO DATE TIME lt CRLF gt Response of the instrument
35. essage tr id and the transmitted string is the following ESC II PIDSS B LLLLLLLLLLUU YYTTTTTTTTTTUU ID NO lt STX gt See the following section Serial commands for the string description NOTES With approved or not approved instrument the storage of the weigh through the PID serial command is always possible for all the weighs from 0 to full range value READING OF THE WEIGHS CARRIED OUT In order to read the information relative to the weighs carried out Press the MODE key The message rew id appears now one should enter the rewriting number from 00000 to 00255 and press PRINT message id appears now one should enter the weigh number from 000000 to 131072 and press PRINT it is possible to view on the display the weigh information in sequence and scroll through it with the ZERO key ahead or the TARE key backwards e ch x in which x is the scale number from 1 to 4 e um yy which yy is the unit of measure kg g t o Ib e gross weight for about a second the message GroSS appears and then the gross weight value e Tare weight for about a second the message tArE appears or tArEpt if it is a manual tare then the tare value appears Press C ON OFF to return to weighing NOTE lf the alibi memory is empty when the MODE key is pressed the message EMPTY appears for about a second one returns to weighing lf the entered ID is not valid in other words if th
36. essing and or integration The filed values may then be recalled from the PC serial line or directly on the indicator s display for a following check NOTE in this mode the zero tracking and the scale ZERO TARE and PRINT key are disabled it s not possible to set the functioning modes and the ALIBI mode is set automatically ONLY TECH MENU USER amp TECH MENU tYPE Ind Ch gt dEP Ch trAnSM To set this mode carry out the following procedure Turn on the scale press TARE while the firmware version is displayed the display shows the menu Press PRINT to enter in the menu the display shows the configured mode of use of the channels Select trAnSM and press PRINT The instrument automatically passes to the following step Press many times the C ON OFF key until the display shows the message SAVE Press PRINT to confirm the changes made or another key to not save FUNCTIONING By pressing the MODE key it is possible to read on the indicator the information relative to the weighs carried out see section 8 5 ALIBI MEMORY READING OF THE EXECUTED WEIGHS section By pressing at length the MODE key one can SWITCH THE CHANNEL if the scale has been configured as multichannel see section 7 11 SELECTION OF THE CHANNEL TO BE DISPLAYED It s not possible to carry out other operations It s possible to only manage the functions which c
37. et as G t or 1st 2nd one is trying to acquire a second time the output weight Er Mot In the counting mode the sampling has not been made because the weight is unstable Error In the counting mode the sampling has not been made because one should use a higher reference quantity Err CLK Communication problems with the date time of the indicator check the F ModE gt gt CLoCK step of the setup TECH MAN REF PREC It is displayed if one tries to calibrate a point without first having confirmed the number of calibration points ERMOT Weight unstable during the acquisition of a point during calibration ERPNT During the acquisition of a calibration point a null value has been read by the converter Er 11 Calibration error a too small sample weight has been used it is advisable to use a weight equal to at least half of the scale capacity Er 12 Calibration error the acquired calibration point tP1 o tP2 o tP3 is equal to the zero point Er 37 Scale to be calibrated TECH MAN REF it is advisable to carry out a technical default dEFAu parameter before proceeding NOTE press the gt T key to access the setup Er 39 Scale to be calibrated TECH MAN REF it is advisable to carry out a technical default dEFAu parameter before proceeding NOTE press the gt lt key to access the setup 37 11 PRINT EXAMPLES WEIGHING NR GROSS 2 000 kg TARE 0 500 kg NET 1 500 kg 00000001 WEIGHING NR
38. he gross weight and vice versa By pressing PRINT at length one enters directly into the INPUT menu of the SET POINTS see section 9 NOTES With an APPROVED instrument The display time of the gross weight is 5 seconds and then the display of the net weight returns While the gross weight is displayed it s not possible to print the weight 8 3 INPUT OUTPUT in out Simple display functioning mode with in out weighing function the indicator acquires two weight values through the confirmation of the operator and calculates the difference automatically printing the data if the presence of a printer has been configured SETTING Once the in out mode has been selected the message tyPE is shown and one is asked to select with PRINT the printing mode of the acquired data Gt gross tare PRINTED DATA GROSS Greater weight with unit of measure TARE Lesser weight with unit of measure NET Difference between GROSS and TARE with unit of measure 18 219 first weigh second weigh PRINTED DATA WEIGH 1 First weight with unit of measure WEIGH 2 Second weight with unit of measure NET Difference without sign between WEIGH 1 and WEIGH 2 with unit of measure in out input output PRINTED DATA INPUT First weight with unit of measure OUTPUT Second weight with unit of measure NET Zero weight with unit of measure gt gt if WEIGH 1 WEIGH 2 INPUT NET gt gt if WEIGH 1 gt WEIGH 2 Difference without sign between I
39. howing the negative functioning of the outputs with active hysteresis in which X indicates the output number IMPORTANT the weight thresholds set with the PRINT key are common to all the connected scales therefore it is not possible to have different thresholds for different scales The value takes on the unit of measure and the decimals of the selected channel for example if one sets 1000 one will have the following set point values Channel Unit of Measure Decimals Set Point Value 1 kg 3 1 000 kg 2 g 0 1000 g 3 kg 2 10 00 kg 4 g 1 100 0 g 3 PCS Set point on the PIECES only for Counting mode By selecting this functioning mode one enables in the normal scale status the function of the outputs on the number of pieces shown on the display the SET POINTS and the specifications are entered the same way as for the functioning on the NET weight in other words it s possible to set the functioning of the set points on the negative number of pieces 4 Gro 0 GROSS WEIGHT AT ZERO By selecting this functioning mode one enables in the normal scale status the function of the outputs on the GROSS weight at 0 5 nEt 0 NET WEIGHT AT ZERO By selecting this functioning mode one enables in the normal scale status the function of the outputs on the NET weight at 6 Motio INSTABILITY By selecting this functioning mode one enables in the normal scale status the function of the outputs on the unstable weight 35 DGT
40. identification plate is supplied separately therefore not attached to the front panel it is advisable to attach it in the appropriate space on the indicator so that it can be identified DGT 06760 DGTQ 5 POWER SUPPLY amp START UP INSTRUMENT POWER SUPPLY DGT and DGTQ models The instrument must be powered with stabilized voltage at 12 Vdc or 24 Vdc supplied from an AC DC external charger not supplied which should be connected to the 220 Vac mains voltage TO POWER the instrument connect the two power supply cables and in the appropriate terminal board section 4 INSTALLATION Fig 4 1 4 4 on the side or on the rear of the instrument DGT60 model The instrument is powered with stabilized voltage at 12 Vdc or 24 Vdc supplied from an AC DC internal charger supplied which should be connected to the 220 Vac mains voltage Safety norms must be respected for the connection to the mains voltage including the use of a line which has to be free from noise generated by other electronic equipment Do not connect other equipment to the same socket as the one that the adapter is in Do not step on or crush the power supply cable TO TURN ON THE INSTRUMENT keep the C ON OFF key pressed until the indicator turns on and then release the key The display executes a start up procedure and will indicate XX YY is the installed software version The indicator has an auto zero at start up function in other words it means that
41. il the message OFF appears on the display and then release the key just the point at the extreme left of the display remains on TO TURN OFF THE INSTRUMENT take away the power supply DGT DGT60 DGTQ 6 FRONT PANEL KEYS AND INDICATORS The front panel of the indicator is designed for quick but simple weighing applications for the user 6 1 DGT The front panel of the DGT consists of a display with 6 digits 13 mm high 6 LED function indicators and a 5 key keyboard kg D G Weight Transmitter NET 8 1 SP2 TARE PRINT ON Stb Figure 6 1 Keys and indicators of the DGT front panel 6 2 DGT60 The front panel of the DGT60 consists of a display with 6 digits 60 mm high 6 LED function indicators and a 5 key keyboard Figure 6 2 Keys and indicators of the DGT60 front panel DGT DGT60 DGTQ 6 3 DGTQ The front panel of the indicator is designed for quick but simple weighing applications for the user It consists of a display with 6 digits 13 mm high 6 LED function indicators and a 5 key keyboard DG T Q Piel m Figure 6 3 Keys and indicators of the DGTQ front panel DGT 06760 DGTQ 6 4 FUNCTION OF THE INDICATORS NUMBER FUNCTION 1 Indicates that the weight detected by the weighing system is near zero specifically within 74 of the division 2 2 Indication of UNSTABLE WEIGHT 3 Indicates that the displayed value is a NET W
42. isition of the stable weight therefore the display of the tot message on the display and then the printing of the data MAx tot number of consecutive totalisations after which the total is automatically printed and reset After having carried out the set weighs the accumulated general total is printed and reset set a value between 0 and 63 NOTE the value 0 disables the function FUNCTIONING TOTALISATION OPERATIONS In order to carry out the totalisation it is necessary to load the weight on the scale and press the MODE key if the automatic totalisation has not been set the weight is accumulated in two total levels a partial total and a general total To totalize the net weight must be at least 1 division with non approved instrument and with normal or fast totalisation at least 10 division with non approved instrument and with automatic totalisation at least 20 divisions with approved instrument 26 DGT DGT60 DGTQ To avoid undesired accumulations the MODE key is active just once it reactivates depending on the setting of the rEACT parameter in the SET UP environment in other words either after passing by the net zero of the scale by instability or always see section 7 9 REENABLING OF THE PRINTOUTS AND THE INDICATOR FUNCTIONS If the presence of a printer has been configured the MODE key causes also the printing of the weight values By pressing the MODE key again without having reenabled the tot
43. it remains in the sum mode otherwise it passes to the repeater mode of the following SLAVE f more than one SLAVE is present and the MASTER is connected to a printer the number of the SLAVE from which the weight comes from will be shown on each printout If the automatic switch off has been enabled the MASTER after about 5 minutes that one is connecting with the SLAVES in other words the ECo n message appears on the display it turns off 8 5 ALIBI MEMORY ALibi OPTIONAL The alibi memory allows to file the transmitted weight values in the computer for data processing and or integration The filed values may then be recalled from the PC serial line or directly on the indicator s display for a following check The storage of a weigh takes place either following the reception of the serial command or following the pressure of the PRINT key the indicator transmits on the PC serial line the gross and tare weights and an ID which clearly identifies the weigh The ID has the following format lt Rewriting number gt lt Weigh number gt Rewriting number number of 5 digits which may go from 00000 to 00255 it indicates the number of complete rewritings of the alibi memory Weigh number number of 6 digits which may go from 00000 to 131072 it indicates the weigh number in the current rewriting of the alibi memory With each storage the weigh number is increased of 000001 when this reaches the 131072 value it restarts fro
44. it s possible to choose which parameter to set select InP PMU The display shows APW and then the stored value expressed with 9 digits with five decimal digits in the programmed unit of measure Enter the APW value using the keys in the following way MODE key to choose the digit blinking ZERO key to decrease TARE key to increase C ON OFF key to quickly clear the present value confirm with PRINT or press twice C ON OFF to exit without confirming Example Unit of measure of the APW in g 0000 00000 means 0 0 g therefore by entering 0001 05000 one will have 1 05 g PRINTING UNDER COUNTING MODE If the presence of a printer has been configured each time PRINT is pressed while either weight or pieces are displayed one prints the data programmed in the SEtuP gt gt SEriAL gt gt CoM Prn gt gt Pr ConF of the set up environment TECH MAN REF for example GROSS weight TARE weight NET weight Quantity of PIECES PCS on the scale in that moment calculated APW expressed in the set unit of measure with three decimal digits 30 DGT DGT60 DGTQ 8 13 SIMULTANEOUS TRANSMITTER OF THE CHANNEL VALUE tYPE trAnSM Independent channel mode which makes it possible to have the simultaneous transmission through the serial line of the values read by each single channel and through the optional alibi memory board it s possible to store the transmitted weight values in the computer for data proc
45. lled MASTER which acts as weight repeater on which it is possible to view the weight of each single scale or the sum of the weight detected by the single scales In the MASTER by selecting with PRINT in this operating mode one is asked to enter the number of the SLAVES which one wants to use for an instant nuMSL is displayed then one enters the number between 01 and 04 In the SLAVES instead one needs to set a different functioning mode than the MAStr and enter a code between 01 and 04 to identify each single SLAVE in SEtuP gt gt SeriAL gt gt CoMPC gt gt PCModE gt gt 485 see set up environment TECH MAN REF NOTES The SLAVE indicators must be of the same model as the MASTER indicator In this functioning mode the printer port may have only the transmission modes to the printer and the rEPE6 transmission mode see section 6 4 TRANSMISSION MODES OF THE SERIAL PORTS TECH MAN REF FUNCTIONING When turned on the MASTER predisposes itself for the connection to the SLAVES present n message appears in which n is the SLAVE number which is to be detected when at least one SLAVE is detected it positions itself on the one with the lowest 485 address pressing the MODE key many times one switches from SLAVE to SLAVE in order by 485 addresses the display shows SCA n in which n is the SLAVE number after this the weight transmitted by the selected SLAVE is displayed In this mode about every 10
46. ly input 2 GND power supply input 3 Connections for serial lines inputs outputs 4 Connections for load cells The instrument may be installed on the wall or on the panel on the DIN bar NOTE When the identification plate is supplied separately therefore not attached to the front panel it is advisable to attach it in the appropriate space on the indicator so that it can be identified DGT 06760 DGTQ 4 2 DGT60 CASE AND DIMENSIONS The indicator has a STAINLESS STEEL case whose external dimensions are shown in FIGURE 4 2 and 4 3 MODEL WITH FIXED BRACKET STANDARD FITTING B M a T Figure 4 2 Measurements and dimensions in mm MODEL WITH STFR ADJUSTABLE BRACKET OPTIONAL 10 ap 2 87 A Jj 1 HI 2 Figure 4 3 Measurements and dimensions in mm 1 Powew supply input 2 Available for load cells serial lines inputs outputs The instrument may be installed on the wall NOTE When the identification plate is supplied separately therefore not attached to the front panel it is advisable to attach it in the appropriate
47. m 000000 and the rewriting number increases of 00001 Therefore the weigh relative to an ID may be verified just if ithasarewriting number equal to the current one of the alibi memory and a weighing number equal or less than the last value received with the PID command it has a rewriting number equal or greater than zero but less than 1 in comparison to the current value of the alibi memory and a weigh number greater than the last value received with the PID command example If the stored weigh is the following PIDST 1 1 000 0 1 000kg 00126 131072 and the following will be PIDST 1 1 000 1 000kg 00127 000000 21 DGT 06760 DGTQ The storage of a weigh is possible only if the weight is stable and valid in other words not in under load nor in overload if the gross weight is equal or greater than zero the storage of the weigh by pressing a key is possible only if the function is active or passage from 0 or weight instability or always depending on how the F ModE gt gt rEACt step has been configured in the technical set up TECH MAN REF and minimum weight of 20 divisions with approved instrument If these conditions are not respected response to the PID serial command one has NO in the place of the ID there is no transmission if PRINT has been pressed When the weight is transmitted with the ID following the pressing of the PRINT key the display shows for about 2 seconds the m
48. nd an ENABLING one which when the gross weight is equal or greater than it enables the output By pressing PRINT at length it s possible to enter the SET POINT value DISABLING and ENABLING for each configured output If the functioning mode provides for the modification of a parameter one enters a submenu in which it s possible to choose which parameter to modify select InP StP The display shows S 1 on output 1 ENABLING SET POINT press PRINT enter the weight value using the keys in the following way MODE key to choose the digit blinking ZERO key to decrease TARE key to increase C ON OFF key to quickly clear the present value confirm with PRINT or press twice C ON OFF to exit without confirming The display shows S 1 oFF output 1 DISABLING SET POINT press PRINT enter the weight value with the keyboard and confirm with PRINT use the C ON OFF key to quickly clear the present value Do the same for the following outputs if present When the programming of the set points is done exit with the C ON OFF key Functioning without hysteresis rL iSt HYSTERESIS parameter set at iSt oFF The functioning mode is the same as the previous except that one enters just one SET POINT for each output 5 1 due to this it s not possible to enter the S 1 oFF parameter NOTES If all the outputs have the NONE functioning mode or if the selected functioning mode does not require the entry of a SET P
49. necessary for any reason where the instrument is used the Customer will pay for all of the service technician s costs travel time and expenses plus room and board if any the Customer pays for the transport costs both ways if the instrument is shipped to DEALER or manufacturer for repair The WARRANTY is VOIDED if any of the following occurs repairs or attempted repairs are made by unauthorised personnel connected to equipment installed by others or is incorrectly connected to the power supply or instrument has defects or damage due to carelessness or failure to follow the guidelines in this instruction manual This warranty DOES NOT provide for any compensation for losses or damages incurred by the Customer due to complete or partial failure of instruments even during the warranty period AUTHORIZED SERVICE CENTRE STAMP 39
50. net weight is equal or less than it the output is enabled By pressing PRINT at length it s possible to enter the NEGATIVE SET POINT values DISABLING and ENABLING for each configured output lf the functioning mode provides for the modification of a parameter one enters a submenun in which it s possible to choose which parameter to modify select InP StP The display shows S 1 on output 1 ENABLING SET POINT press PRINT enter the weight value using the keys in the following way MODE key to choose the digit blinking ZERO key to decrease TARE key to increase C ON OFF key to quickly clear the present value confirm with PRINT or press twice C ON OFF to exit without confirming The display shows S 1 oFF output 1 DISABLING SET POINT press PRINT enter the weight value with the keyboard and confirm with PRINT use the C ON OFF key to quickly clear the present value Do the same for the following outputs if present When the programming of the set points is done exit with the C ON OFF key 34 DGT DGT60 DGTQ FUNCTIONING WITHOUT HYSTERESIS rL iSt HYSTERESIS parameter set at iSt oFF The functioning mode is the same as the previous except that one enters just one SET POINT for each output S 1 due to this it s not possible to enter the S 1 oFF parameter A OUTPUT X STATUS 4 gt ENABLED 4 gt DISABLED gt 5 SX oFF NET WEIGHT Figure 9 3 Diagram s
51. ng in 485 mode XXXXX rewriting number from 00000 to 00255 character ASCII decimal 45 YYYYYY weigh number from 000000 to 131072 Instrument response I B LLLLLLLLLLUU YYTTTTTTTTTTUU CR CRLF gt In which ll 485 address only when transmitting in 485 mode B scale number from 1 to 4 comma character ASCII decimal 44 LLLLLLLLLL gross weight on 10 digits UU unit of measure YY spaces in the case of null or semiautomatic tare PT in the case of manual tare TTTTTTTTTT tare weight on 10 digits ALIBI MEMORY CANCELLATION only with non approved instrument Command IIJALDL CR o CRLF gt In which II 485 address only when transmitting in the 485 mode Instrument response IIJALDLOK CR o CRLF gt if the cancellation has been effective IJALDLNO CR o CRLF gt if the cancellation has not worked The commands are ignored if one is not in the alibi memory functioning mode 8 6 SINGLE SCALE REPEATER rEPE The system is made up of one or more indicators named REPEATERS which receive the data of the display or of the weight from another indicator or from a PC PLC named TRANSMITTER and which therefore act as repeaters In the REPEATERS once this functioning mode has been set one should configure the rEPE 6 or W rEPE parameter the communication mode of the PC port SEtuP gt gt SEriAL gt gt CoM Pc step TECH MAN REF For further configuration and functioning details refer to the technical manual
52. nu see section 9 NOTE if one connects various scales to the indicator in order to pass from one scale to the other one should exit the HOLD mode unblocking the frozen weight 8 9 PEAK WEIGHT PEAKS DETECTION It is possible to use the instrument to store the maximum weight value measured during the weigh PEAK useful to measure for example the breaking load of the materials FUNCTIONING By pressing the MODE key the peak mode is enabled and the display shows every 5 seconds alternated with the maximum weight reached up until that moment The test terminates by pressing the MODE key again or when the weight peak surpasses the maximum capacity of the instrument for an instant PEAk oF is displayed and then the display shows the weight on the scale once again The detected weight value will be e The maximum before a rapid decrease of the weight measurement of the ultimate load e The maximum and persistent weight detected on the scale Toseta SET POINT one should press at length for about 3 seconds the PRINT key If the functioning of a output upon reaching a set point has been configured one enters a submenu in which it s possible to choose which parameter to modify select InP StP see section 9 25 DGT DGT60 DGTQ SETTING SAMPLING TIME It is possible to set the minimum time period of the peak impulse beyond which the measuring is accepted Press PRINT at length f the functioning
53. o scroll backwards to find the SCr SAV parameter Press PRINT to enter the parameter With the ZERO or TARE key select the possible options no disabled YES enabled Confirm with PRINT if one has selected YES one is asked to enter the number of minutes after which the indicator should show the time enter a number between 1 and 255 using the MODE key to select the digit to be modified and the ZERO TARE keys to decrease increase it and confirm with PRINT Press the C ON OFF key many times until the display shows the message SAVE Press PRINT to confirm the changes made or another key to not save NOTE the SCr SAV parameter is not shown if there is no date time option DGT 06760 DGTQ 7 8 PRINTING If a printer is connected it is possible to print the programmed weight data for example 4heading lines of 24 characters GROSS weight weight weight ticket number date and time optional CODE 39 bar code both with the LP542PLUS labeller as well as the TPR thermal printer Besides the generic printing described above each single functioning mode will have some specific printouts which are described in the operating mode Executing printouts with NON approved scales In order to print with non approved scales the following conditions must exist the weight must be stable the gross weight must be gt 0 the printout is always active NOTE In the tot
54. osfet outputs expandable to 6 through option for the DGTQ model NO or NC configurable programmable weight thresholds DGT and DGT60 models 48 Vac 0 15 A max or 60 Vdc 0 15 A max DGTQ model 48 Vac 0 12 A max or 60 Vdc 0 12 A max 2 configurable inputs optoisolator Photocouplers 12 24 Vdc 5 mA min 20 mA max Input reading time and output refreshing time 1msec Analogue output at 16 bit at choice 4 20 mA 0 5 Vdc or 010 DGT4AN and DGTQAN versions the maximum resistance applicable on the output current is 350 Ohm and the minimum resistance applicable on the output voltage is 10 kohm To call the attention of the user the following symbols are used both in the manual and on the instrument itself AN Warning This operation must be performed only by qualified personal C CE CONFORMITY CID IDENTIFIES THE CLASS OF PRECISION TECH MAN REF means that an advanced function is being described therefore for the technical personnel which will be further explained in the corresponding technical manual DGT DGT60 DGTQ 4 INSTALLATION 4 1 DGT CASE AND DIMENSIONS The indicator has a plastic case whose external dimensions are shown in FIGURE 4 1 52 VV VN ON OOD FTN FIN EIS at EIS FEIERN an Figure 4 1 Measurements and dimensions in mm 1 12V 24 Vdc power supp
55. r into the no 0 unS error shown on the display this means that the printing or the function which one wants to carry out must be reenabled in order to avoid unwanted executions It is possible to set the reenabling in different ways passage by zero of the net weight weigh instability or always Follow the procedure below on the scale press the TARE key while the firmware version is displayed the display shows the menu Select F ModE by pressing once the ZERO key and press PRINT to enter in the menu Press ZERO many times to scroll forwards through the parameters or TARE to scroll backwards until one finds the rEACt parameter Press PRINT to enter the parameter With the ZERO or TARE keys select the possible options ZEro passage by zero of the net weight inSt instability ALWAyS Confirm with PRINT Press the C ON OFF key many times until the message SAVE is shown on the display Press PRINT to confirm the changes made or another key to not save 15 DGT 06760 DGTQ 7 10 DISPLAY OF METRIC DATA inFO The indicator is fitted with a function named INFO thanks to which it is possible to view the metric data and other configuration data First range capacity first range minimum weigh first range division Second range capacity second range minimum weigh second range division if set Gravitational Acceleration Value Number of configured Channel
56. relative to the type of printer selected in the SEtuP gt gt SEriAL gt gt PrMODE see TECH MAN REF parameter It is possible to activate the default parameters by carrying out the selected print default see section 8 TECH MAN REF 8 1 UNIT OF MEASURE CONVERSION Std Simple display functioning mode with the function of conversion between the scale unit of measure and Ib and viceversa FUNCTIONING By pressing the MODE key the weight conversion between the scale unit of measure and Ib is made and vice versa By pressing the PRINT key at length one directly enters the SETPOINT INPUT Menu see section 9 NOTES f one connects various platforms to the indicator in order to pass from one platform to the other the weight must be expressed in the scale unit of measure conversion takes place for any unit of measure set during the calibration Furthermore with APPROVED instrument The weight in pounds is displayed for 5 seconds after which the display goes to the scale unit of measure During the viewing in pounds it is not possible to print the weight when pressing PRINT the message ConV is shown By pressing the PRINT key at length one enters directly into the INPUT menu of the SET POINTS see section 9 DGT 06760 DGTQ 8 2 NET GROSS SWITCH ntGS Simple functioning mode with Net Gross conversion function FUNCTIONING dfatare is set by pressing MODE the display switches between the net and t
57. s NOTES minimum weigh corresponds to 20 net weight divisions The data of the second and third range appear only if actually configured To view the metric data Keep the C ON OFF key pressed until the display shows inFO and release The capacity value of the first range will appear Press the ZERO key to scroll the following data in the order for example for channel 1 1st range capacity Ch1 MAX 1st range minimum weigh Ch1 Min gt 1st range division Ch1 E 2nd range division Ch1 MAX 2nd range minimum weigh Ch1 Min gt 2nd range division Ch1 E Gravitational Acceleration Value GrAVit Nr of Configured Channels ConF Ch gt and so on these repeate cyclically Press the TARE key to scroll backwards through the metric data Press the PRINT or C ON OFF key to return to weighing By pressing the MODE key during the display of the info for the currently active channel it is possible to view the metric data of the other channels if configured for example if also channels 2 and 3 are configured for the maximum capacity of the 1st range 1st range capacity channel 1 Ch1 MAX Press MODE gt 1st range capacity channel 2 Ch2 MAX Press MODE gt 1st range capacity channel 3 Ch1 MAX 7 11 SELECTION OF THE CHANNEL TO BE DISPLAYED In all the functioning modes excluding the MASTER mode Par 8 4 Multiscale repeater it is possible to select the
58. s displayed when one selects the alibi memory functioning mode and upon start up the alibi memory is not connected or there are communication problems between the indicator and the board The Unit of measure conversion functioning is automatically set but not saved in the set up environment BuSy Print under way PRN serial port is occupied or indicator waiting to transmit a printing to a PC UnStAB One is trying to print with an unstable weight un oVEr One is trying to print with the weight in under load or in overload in other words with a weight of 9 divisions greater than the capacity or of 100 divisions below the gross zero GroS Er One is trying to print with a not positive gross weight equal or less than zero Net Err One is trying to print with a not positive net weight equal or less than zero LoW Net weight less than the minimum weight provided for the printing or the totalisation no 0 unS Weight not passed by net 0 or by instability ConV In standard mode with approved instrument one is trying to print while the instrument is converting the unit of measure no in In the input output mode set as in out one is trying to acquire a second time the input weight no out In the input output mode set as in out one is trying to acquire a second time the output weight no 1 In the input output mode set as G t or 1st 2nd one is trying to acquire a second time the input weight no 2 In the input output mode s
59. se it and confirm with PRINT Press many times the C ON OFF key until the display shows SAVE Press PRINT to confirm the changes made or another key for not saving DGT DGT60 DGTQ 7 5 MULTI RANGE FUNCTIONING for legal for trade approved instruments The multirange functioning allows to subdivide the scale capacity in two or three ranges each which is up to 3000 divisions improving in this way the first range division in the dual range For example with a 10 kg cell platform it is possible to approve the weighing system with A single range 6 kg capacity and 2 g division 3000 div Dual range 6 3 kg capacity and 2 1 g division 3000 3000 div NOTES For the approval of the weighing system in dual range the cell must have better technical features in comparison to the cell used for the approval in a single range The multirange functioning is shown by the turning on of the relative LED which identifies the range in which one is Operating by passing to the second range the second range division is enabled At this point the first range division is restored only by passing by the gross zero of the scale The selection of the range number with multirange functioning is made during the indicators calibration TECH MAN REF 7 6 DATE TIME ADJUSTMENT OPTIONAL The indicator can be fitted with the date time option in this case the CLoCK message is shown when the instrument is turned on To set the d
60. son If any welcome problem with the unit or system has been experienced please notify the manufacturer or the dealer from which the instrument was acquired Do not pour liquids on the indicator Do not use solvents to clean the indicator Do not expose instrument to either direct sun light or any heat sources Always mount the indicator and platform in a vibration free setting All indicator connections must be made respecting the norms applicable to the zone and environment in which it will be installed Read carefully amp apply what described in the POWER SUPPLY amp START UP section Do not install in an environment with any risk of explosion RECYCLING INSTRUCTION The crossed out wheeled bin on the product means that at the product end of life it must be taken to separate collection or to the reseller when a new equivalent type of equipment is purchased The adequate differentiated refuse collection in having the product recycled helps to avoid possible negative effects on the environment and health and supports the recycling of the materials of which the equipment is made The unlawful disposal of the product by the user will entail fines foreseen by the current regulations DGT 06760 DGTQ 2 MAIN TECHNICAL SPECIFICATIONS POWER SUPPLY MAXIMUM ABSORPTION OPERATING TEMPERATURE DISPLAY DIVISIONS CONVERSION SPEED MINIMUM VOLTAGE PER DIVISION COUNTING RESOLUTIONS DISPLAY INDICATIONS KEYBOARD T
61. space on the indicator so that it can be identified DGT DGT60 DGTQ 4 3 DGTQ CASE AND DIMENSIONS The indicator has a plastic case whose external dimensions are shown in FIGURE 4 4 1 S 0 A paa N d D De a MON 2 Sy C O N DO FW BAP NIN x yeas la LLZ N V E 4 y CO exce 5 S M EN e x eats tee SEN AG T JI fise CO ao Ads p ees OM Y D e pr C x z bud i aN 5 p CAL EN KK 9r ER fos LES REESE J V L e NL aS nz SY C COM 1 C N L_ X a 5 27 n T i ND Y T PASEAR lt LOAD CELL 1 a ES CE ege MULTICHANNEL S BUS 1 Figure 4 4 Measurements and dimensions in mm 1 Power supply cable input 2 GND power supply input 3 Connections for serial lines inputs analogic output 4 Connection for load cell 5 Connections for outputs The instrument may be installed on the panel NOTE When the
62. the NET WEIGHT TOTAL is printed To print and zero the GENERAL TOTAL one should press at length the PRINT key If the functioning of a output upon reaching a set point one enters a submenu in which it s possible to choose which parameter to be modified select Pr G tot Depending on the type of totalisation various messages will be displayed With normal totalisation the number of weighs and the accumulated total will be displayed With fast or automatic totalisation the message G totAL will be displayed The number of weighs made and the NET WEIGHT TOTAL is printed NOTE All the accumulated values are automatically reset each time the instrument is turned off SETTING OF SET POINT To set a SET POINT one should like for the General Total printout press the PRINT key for about 3 seconds If the functioning of a output upon reaching a set point one enters a submenu in which it s possible to choose which parameter to be modified select InP StP see section 9 2T DGT 06760 DGTQ 8 11 VERTICAL TOTALIZER Sum by recipe tot S Like the horizontal totaliser but with each pressing of MODE the indicated weight is totalised and automatically tared in this way it is possible for example to fill a container with various products Note At the end of the totalisation operations if one wants to view the gross weight on the scale one should press the ON OFF key 8 12 PIECE COUNTING Coun This functioning mode allows to
63. ual is to help the user get to know the weight indicator s various functioning modes the keys functions and the display indications It is possible that one may incur into the phrase TECH MAN REF this means that an advanced function is being described therefore for the technical personnel and which is further explained in the corresponding technical manual We advise to carefully follow the instructions for programming the weight indicator by taking actions not indicated this manual one could cause the scale to not work properly In addition to having all the characteristics of a high precision scale the indicator has the unit of measure conversion function switching in the display net gross weight set point on gross weight net weight pieces in out weigh multiscale repeater alibi memory hold function peak detector weighs totaliser and piece counter These features make it suitable for industrial use as well as for legal for trade use in relation with third parties and in commerce satisfying the frequently needed ability to transmit and print the data through its two bidirectional serial ports This manual has been made as carefully and exactly as possible in any case your suggestions are always IN WARNING IN Any attempt to repair or alter the unit can expose the user to the danger of electric shock and it will void our warranty This instrument is covered under warranty provided that IT HAS NOT BEEN OPENED BY THE USER for any rea