INSTALLATION MANUAL

image

Contents

1. Placing and connecting the CD 3 self service Page 9 Installation Manual Hot Deli 3 4 5 form 9123584 09 2007 PLACING AND CONNECTING OF THE UNITS fri jado COLD DELI 4 FULL SERVE Placing and connecting the CD 4 full service Page 10 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 fri jado PLACING AND CONNECTING OF THE UNITS COLD DELI 4 SELF SERVE Q w 1419 1058 534 Installation Manual Hot Deli 3 4 5 form 9123584 09 2007 Placing and connecting the CD 4 self service Page 11 PLACING AND CONNECTING OF THE UNITS ZZ fri jado COLD DELI 5 FULL SERVE T 81
2. Placing and connecting the CD 4 on pedestal underframe Page 15 Installation Manual Hot Deli 3 4 5 form 9123584 09 2007 PLACING AND CONNECTING OF THE UNITS fri jado COLD DELI 5 ON PEDESTAL UNDERFRAME 1752 1730 1058 Placing and connecting the CD 5 on pedestal underframe Page 16 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 ZZ fri jado PLACING AND CONNECTING OF THE UNITS COLD DELI 3 ON UNDERFRAME WITH CASTORS 1086 t t LES t LEA 0771 70 1064 Installation Manual Hot Deli 3 4 5 form 9123584 09 2007 Placing and connecting the CD 3 on underframe with castors Page 17 PLACING AND CONNECTING OF THE UNITS fri jado COLD DELI 4 ON UNDERFRAME WITH CASTORS 1419
3. ee 7 2702 1058 Placing and connecting the CD 4 on underframe with castors Page 18 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 fri jado PLACING AND CONNECTING OF THE UNITS COLD DELI 5 ON UNDERFRAME WITH CASTORS 1730 1058 Installation Manual Hot Deli 3 4 5 form 9123584 09 2007 Placing and connecting the CD 5 on underframe with castors Page 19 PLACING AND CONNECTING OF THE UNITS fri jado COLD DELI DROP IN DIMENSIONS PART 1 Partition Panel D End Panel Air Inlet min 400x400 Air Outlet min 400x400 Page 20 Placing and connecting a CD built in situation part 1 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 fri jado PLACING AND CONNECTING OF THE UNITS COLD DELI DROP IN DIMENSIONS PART 2 452 A Air Inlet min 400x400 Air Outlet min 400x400 Partition Panel D End Panel Optional
4. Placing and connecting the CD 5 full service Page 12 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 fri jado PLACING AND CONNECTING OF THE UNITS COLD DELI 5 SELF SERVE ssi s T tt u Se a 4 z Placing and connecting the CD 5 self service Page 13 Installation Manual Hot Deli 3 4 5 form 9123584 09 2007 PLACING AND CONNECTING OF THE UNITS fri jado COLD DELI 3 ON PEDESTAL UNDERFRAME 1086 1064 027 ccoc Placing and connecting the CD 3 on pedestal underframe Page 14 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 fri jado PLACING AND CONNECTING OF THE UNITS COLD DELI 4 ON PEDESTAL UNDERFRAME 1387 1058
5. 5 Unpacking and removing the unit from the 5 5 Separately packed P ris uu u a 6 E N 7 itin d dante Met dmi E 7 DS p LC 7 nsfructions for oos imde IR qM iU UU NK 7 Placing and connecting of the units 8 Cold Deli 5 21 ea ode cence mea oe eae 8 Celd Deli 3 self sayeuuuu TEENS 9 Cold Delr4 full seNe uuu a e 10 Cold Deli self server usa 11 Cold Deli 12 ei 13 Cold Deli 3 on pedestal Une epe a vesper ni ER RUD YER opea 14 Cold Deli 4 on pedestal underfrome re Ra ERE 15 Cold Deli 5 on pedestal underfrome p Rp estes iri Aa x PER 16 Cold Deli ndertrame
6. Driptray Placing and connecting a CD built in situation part 2 Page 21 Installation Manual Hot Deli 3 4 5 form 9123584 09 2007 PLACING AND CONNECTING OF THE UNITS fri jado COLD DELI 3 AND 4 MODELS COUPLED E i 10 104 104 1211 2507 210 878 096 1058 Page 22 Cold Deli 3 4 models coupled Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 fir fri jado worldwide retail solutions Fri Jado B V P O Box 560 4870 AN Etten Leur The Netherlands tel 31 76 50 85 400 fax 31 76 50 85 444 info frijado com www frijado com
7. usse qaid afe ap 17 Cold Deli 4 undertrame With COSIO S eo ge EEE EEA EE EE EE 18 Cold Deli 5 undertrame With COSTOS tinte aaa RR waqasqa 19 Cold Deli drop in dimensions part 1 eR Rp ERI Kel HEnERC EPRRERUGUPRO n DAE RRU PERDU RP 20 Cold Deli drop in dimensions part 2 ea medo pU ta nO FER pent DU 21 Cold Deli 3 and 4 models coupled ert pie eer Pent CORDE Up 22 Page 3 Installation Manual Cold Deli 3 4 5 form9123584 09 2007 ENERAL TECHNICAL DATA ZZ fri jado GENERAL TECHNICAL DATA This manual covers the Cold Deli Merchandisers The Merchandisers are available in 3 sizes which can be built into existing counters Merchandisers can also be delivered on an under frame The Merchandisers are available in 2 versions Self Service Full Service All of the information illustrations and specifications contained in this manual are based on the latest product information availble at the time of printing TECHNICAL DATA CD 3 CD 4 CD 5 Power 866 W 1068 W 1198W Fuses needed with power connection 1x 10A 1x10A 1x 10A 230V 1N 50Hz 1 phase w
8. INSTALLATION MANUAL COLD DELI 3 4 5 MERCHANDISERS VERSIONS Self service Full service CD 3 self service on pedestal underframe NOTICE This manual is prepared for the use of trained Service Technicians and should not be used by those not properly qualified If you have attended a trianing for this product you may be qualified to perform all the proce dures in this manual This manual is not intended to be all encompassing If you have not attended a training for this product you should read in its entirety the repair procedure you wish to performto determine if you have the neces sary tools instruments and skills required to perform the procedure Procedures for which you do not have the necessary tools instruments and skills should be performed by a trained technician Reproduction or other use of this Manual without the express written consent of Fri Jado is prohibited Zr fri jado worldwide retail solutions WWW FRUADO COM Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 Z fri jado SNP UY PAGI Page 2 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 fri jado INDEX Lale E aa 3 General technical data u uy 4 clea a oc s m n amu uuu hele mere cere weer Exe bec tuber ee 4
9. ith zero Standard plug from factory single pole Two pole Two pole Two pole earthed plug earthed plug earthed plug 16A 16A 16A sound pressure 70 dB A 70 dB A 70 dB A Temperature class Self Service 2M2 2M2 2M2 Temperature class Full Service 3MI 3MI 3MI Net Weight Self Service 195 kg 225 kg 265 kg Net Weight Full Service 200 kg 230 kg 275 kg Gross Weight Self Service 250 kg 290 kg 340 kg Gross Weight Full Service 255 kg 295 kg 345 kg Heigth 1307 mm 1307 mm 1307 mm Width 1086 mm 1419 mm 1752 mm Depth 1058 mm 1058 mm 1058 mm Heigth with basis 1420 mm 1420 mm 1420 mm Maximum Loading height 100 mm 100 mm 100 mm Refrigirant R134A R134A R404A Amount of refrigirant 0 625 kg 0 75 kg 0 85 kg Product temperature class according to NEN EN 441 6 The refrigerant complies with the environmental requirements applicable at the time of manufacturing of the unit Tools Standard set of tools Metric wrenches sockets and hex socket key wrenches Multi meter and AC current clamp meter Temperature tester Insulation value tester Megger Page 4 ki Installation Manual Cold Deli 03 4 5 form 9123584 rev 9 2007 fri jado INSTALLATION PROCEDURES INSTALLATION PROCEDURES Unpacking of the unit Remove the pallet under the unit with the help of a fork lift Put the unit on his location Unpack and install all separately packed parts Remove all vinyl protection Check if there is enough free
10. r of the unit has to be instructed The instruction has to cover the following subjects Programming options Working of the unit Free space of unit for servicing and for proper operation Run through the user manual Cleaning of the unit How to react for obtaining information or making service calls Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 PLACING AND CONNECTING OF THE UNITS fri jado PLACING AND CONNECTING OF THE UNITS Description belonging to the lables on the drawings Label Description Power cable length 2 5 meters length is measured from the point where the cables comes out of the unit COLD DELI 3 FULL SERVE 104 Placing and connecting the CD 3 full service Page 8 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 fri jado PLACING AND CONNECTING OF THE UNITS COLD DELI 3 SELF SERVE oy o 1 I I 0 2 co cO I 0 y
11. remove cleanser residues and then dry the entire unit 3 Place all optional parts and or accessories Follow steps 1 to 3 to place the glass side panels and sliding doors and follow steps 4 to 7 to place a pan frame 4 Insert the plug into the socket 5 Switch on the unit 6 Let the unit cool for at least half an hour before filling it with products Page 6 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 fri jado INSTALLATION PROCEDURES ELECTRICAL SUPPLY Prior to installation test the electrical service to assure that it agrees with the specifications on the machine data plate located on the middle backside panel near the controls The connecting cable for the unit must be equipped with an approved plug connection If use is to be made of a perma nent connection the connecting cable must be connected to a manual on off switch that is installed near the unit in a clear visible way LEGS CASTORS Each Merchondiser is furnished on 120 mm adjustable legs Units placed on a pedestal have no adjustable legs The pedestal must be installed on a level surface Units placed on a underframe are furnished with 2 swivel and 2 locking swivel castors TEST RUN Operate the cold deli merchandiser at a minimum temperature setting of for 30 minutes Wit hin these 30 minutes the merchandiser should reach the adjusted temperature INSTRUCTIONS FOR OPERATORS After installation of the Merchandiser the operato
12. space around the unit 50 mm Check the electrical supply Check all settings and make a test run with all functions switched on Give instructions to the operator AND THE UNIT FROM THE PALLET Immediately after unpacking the Merchandiser check for possible shipping damage If the Mer chandiser is found to be damaged save the packaging material and contact the carrier within 15 days of delivery Remove the pallet under the unit with the help of a fork lift LOCATION The Merchandiser must be installed on a level surface Level the unit with the adjustable legs The installation location must allow adequate clearances for servicing and for proper operation Page 5 Installation Manual Cold Deli 3 4 5 form 9123584 09 2007 INSTALLATION PROCEDURES ZZ fri jado SEPARATELY PACKED PARTS Clean and place all parts and or accessories Follow steps 1 to 3 to place the side glass and sliding doors and follow steps 5 to 7 to place the pan frame Caution Handle glass panels with care to avoid breakage The side glass panels are tempered safety glass If the edges of the glass panels scrape against stainless steel concrete or other hard surfaces breakage may occur 1 Clean the inside the removable parts and the accessories thoroughly with a cleanser and water before putting the unit into use 2 After cleaning wipe the unit with a cloth moistened with clean water to