Home
Honeywell CS10XE Air Cooler Manual
Contents
1. deposits on blower In cooling mode the Air Cooler produces moisture as a result of evaporative cooling This is normal When the Cooler is new Algae or mold due to moist parts In very damp conditions algae may form Remote control batteries are old amp used or inserted incorrectly in the battery compartment Damaged remote control Damaged Control Panel on unit The Air Cooler was placed outdoors this is only allowed for outdoor Air Cooler models and soaked by heavy rain SOLUTION Make sure power cord is plugged in and the switch is ON Turn the unit ON by pressing the power button on the control panel or remote control Turn on COOL function from remote or control panel Refill water tank Contact Customer Service Center The Air Cooler cools best in dry climates If the ambient humidity level is high 60 or above refrain from using the Air Cooler until ambient humidity is reduced Make sure the window doors are open and there is adequate cross ventilation in the room so that the moisturized air can circulate better Do not use the evaporative cooling function on days with high ambient humidity When the unit is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate within a few hours of initial use Check the Honeycomb Cooling Media If you see mold spots on the media or suspect an algae issue remove and replace the Honeycomb Cooling Medi
2. Open the battery compartment at the back of the remote control and insert battery inside Care must be taken to insert the batteries according to the correct polarity markings shown inside the battery compartment e Always point the remote control signal transmitter towards the unit when operating Make sure that he signal path is not obstructed Remove the batteries if the unit is not going to be used for an extended period of time Do not drop the remote control Do not mix different types of batteries such as alkaline carbon zinc or rechargeable batteries Do not mix old and new batteries Exhausted batteries are to be removed from the product Do not dispose of batteries in fire Batteries may explode or leak COOLER LOCATION Make sure to position the air cooler correctly before you set up and start using the product Please refer to the COOLER LOCATION section of the separate Safety amp Maintenance Guide FILLING WITH WATER CAUTION Unplug the unit from the electrical power outlet before emptying or refilling the water tank Open the Water Fill Tray located at the back of the unit The Water Level Indicator is located at the side of the unit Refill the water tank when water level is low Do not fill water above the Max water level mark Check the water level in the tank before running the 8 COOL function Make sure that the water in the tank is above the minimum water level mark Running the unit in COOL mode with in
3. high mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits If mineral deposits remain on the Honeycomb Cooling Media the media should be removed and washed under fresh water The media should be cleaned every two months or sooner depending on your needs e For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off Figure 1 Honeycomb Cooling Media Carbon Dust Rear Grill Filter J Honeycomb Screws Frame Removing the Carbon Dust Filter Honeycomb Cooling Media 1 Remove all the screws from the Rear Grill of the Air Cooler 2 Carefully pull out the rear grill from the cooler 3 Slide out the Carbon Dust Filter and clean with water 4 To release the Honeycomb Media remove the Honeycomb Frame screws and pull the Honeycomb Frame out of the unit 5 Remove the screws on the base of the Honeycomb Frame and slide out the Honeycomb Cooling media Replace or clean media with water and a damp cloth as needed WARNING DO NOT operate the Air Cooler when the Rear Grill is removed from the Air Cooler or if there is a loose fitting Rear Grill Doing so can cause serious injury or dangerous electrical shock Applicable for models with Carbon Dust Filter only JMATEK North America LLC Mahwah
4. H Kele7 wile To maximize efficiency position the Air Cooler according to the following guidelines Indoors Place the cooler in front of an open door or window Ensure that there is adequate cross ventilation in the room by leaving a door or window open opposite the cooler s The Evaporative Air Cooler should not be used in enclosed spaces It must be kept level and there must be water in the water tank Doors and windows should be opened to allow free air flow The Evaporative Air Cooler works best when placed near an open window so that outside air is drawn into the Evaporative Air Cooler circulates in the room then exits via the door The maximum cooling effect is felt when a person is near the flow of air coming out of the Evaporative Air Cooler The Evaporative Air Cooler produces moisture and can be used to humidify dry air To be used for humidification the windows and doors should be closed IMPORTANT The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas It should not be expected to cool as efficiently as a refrigerated air conditioner Outdoors for outdoor models only e Use only on GFCI Protected outlets sockets for USA only Power cords must be secured to avoid tripping The wiring and connections must be protected from water The electrical plug and Air Cooler connections must be dry at all times e Set the unit on a solid flat surface IMPORTANT Honeywell Ou
5. Honeywell Portable Evaporative Air Cooler Safety amp Maintenance Guide User tips and safety instructions www honeywellaircoolers com E mail info honeywellaircoolers com THANK YOU Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler The Safety amp Maintenance Guide and the separate User Manual are intended to provide you with important information needed to set up operate maintain and troubleshoot this product USER TIPS What is Evaporative Cooling Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep energy costs low Warm air is drawn into the cooler and enters the Honeycomb Cooling Media Water pumped from the water tank pours over the Honeycomb Cooling Media As the warm air passes through the Honeycomb Cooling Media the water absorbs the heat naturally cooling and humidifying the air A fan propels the cooled air out into the room This no compressor system cools naturally efficiently and inexpensively Honeycomb Cooling Media Evaporative Air Cooling Mechanism The recommended maximum relative humidity level is 60 or less which allows a noticeable temperature decrease The temperature will be lower in drier climates because higher evaporation occurs when the humidity is low NOTE When the product is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate in a few hours or so of initial use fefole m
6. New Jersey 07495 USA Phone 1 800 474 2147 Email usinfo jmatek com Web www jmatek com Made in China 2015 JMATEK Limited All rights reserved The Honeywell Trademark is used under license from Honeywell Intemational Inc Honeywell International Inc makes no representations or warranties with respect to this product This product is manufactured by JMATEK Limited Honeywell
7. a Contact the Customer Service Center for more information Check water tank amp other cooler parts If you see mold spots or suspect an algae issue use a damp cloth to wipe away the algae until all spots have disappeared Make sure all parts are clean amp dry before storage Contact the Customer Service Center if problem persists Replace with new batteries Follow the polarity guide inside the battery compartment If replacing new batteries in the correct position does not work contact the Customer Service Center Try to activate the unit with the Remote Control If the unit responds then the Control Panel on the unit may be experiencing problems contact the Customer Service Center If neither the Remote Control or the Control Panel is working contact the Customer Service Center A small amount of rain on the unit is not a problem as long as the electrical plug and outlet are dry If they are wet DO NOT touch the unit or electrical plug outlet Switch off the master power for the outlet before unplugging the unit from the electrical outlet Make sure all outlets and plugs are dry before use The Air Cooler is designed to IPX4 product standards and not recommended to be placed outdoors during heavy rain conditions Do not operate the Air Cooler when wet Wait for the Air Cooler to dry before plugging in and turning on the unit again Honeywell Portable Evaporative Air Cooler User Manual Read and save these in
8. adequate water may cause pump failure LOW WATER ALARM The unit is equipped with a low water sensor In Cooling Mode when water in the tank is below the minimum level you will hear a beeping sound and the amp will flash continuously The unit will automatically pause evaporative cooling Refill the water tank to deactivate the alarm in cooling mode First switch OFF the unit and unplug from the power outlet Fill the water tank with water above the minimum water level mark Plug in and switch ON again To deactivate the alarm and continue using the unit as a fan without evaporative cooling switch the unit OFF and then ON again The Low Water Alarm will not activate in Fan only mode The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty CLEANING amp DRAINING THE WATER TANK Below are instructions on how to clean and maintain your air cooler If the cooler will not be used for a long period of time please refer to the STORAGE amp MAINTENANCE GUIDELINES located in the separate Safety amp Maintenance Guide WARNING Before cleaning the unit switch the unit OFF and disconnect from the electrical socket e Move the unit to a location where the water can be drained Remove the cap from the Drain plug located at the bottom of the unit Allow the tank to empty e Detach the water tank by unlocking the Detachable Water Tank Latches on both sides of the unit Lift he coo
9. ance is not intended for use physical sensory or mental capabilities or la lamaged or if it malfunctions Refer to the by persons including children or elderly with reduced ck of experience and knowledge unless they have been given supervision or instructions concerning the use of the appliance by a person responsible for their safety e Always grip the side handles to move the Air e WARNING To reduce the risk of fire or electric shock do not use this appliance with any solid state speed control device Cooler Read the detailed CLEANING amp DRAINING THE WATER TANK instructions for your Air Cooler located in the separate User Manual Below is a general guideline for maintenance and storage of your Air Cooler WARNING Always switch OFF the Air Cooler and unplug it from the electrical source before cleaning or maintenance Cleaning At least once a week drain the water lank completely and refill with fresh water Doing this will greatly reduce mineral deposits and help to extend the life of the Honeycomb Cooling Media End of Season Storage If the Air Cooler will not be used for a long time e Make sure all parts are dry by running the Fan Only mode for about 30 minutes before storing time depends on ambient humidity conditions e Switch OFF the Air Cooler and unplug from he power supply e Empty drain all the water from the tank Note If the unit is connected to a continuous water suppl
10. he unit e Never pull the cord Remove it from the electrical outlet socket by grasping and pulling on the plug end of the cord e This appliance has been manufactured for use in domestic environments and must not be used for other purposes e DONOT use in areas where gasoline paint or other flammable goods and objects are stored e When using the COOL setting make sure the water tank is at Max Indicator Level Operating the unit on the COOL setting with an empty tank may result in damage to the water pump e DONOT attempt to repair or adjust any electrical or mechanical functions of the Air Cooler as this may void the warranty e DONOT cover the cooler s air inlet or outlet as this may damage the motor e DONOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the unit and may cause electrical shock or fire e DONOT operate with the Honeycomb Cooling Media removed as this will overload and damage the motor e DONOT leave the operating appliance unattended for an extended period of time e DO NOT allow children to play with this appliance packaging or plastic bags e DONOT continue to operate the unit if it is d TROUBLESHOOTING section and contact the CUSTOMER SUPPORT CENTER e Always place the unit on a dry level floor use in bathrooms or near water DO NOT keep the product where it may fall into a water e DONOT container e Store in a dry area when not in use e This appli
11. ler upwards away from the base and place it carefully and vertically on the floor Be careful not 0 bend the water pump tubes and other parts that will hang from the bottom of the unit when the body is removed from the tank e Refill the water tank with clean water and drain it completely Clean the water tank with dish detergent or a damp cloth and rinse it thoroughly e Refill the water tank with clean water up to the maximum level e Replace the top of the air cooler carefully back onto the tank and lock the side latches The air cooler is now ready to be used e Use a damp cloth to remove dirt and dust from the surface of the unit Never use corrosive elements or chemicals to clean this product When the product is not in use store the unit in a dry place out of direct sunlight CLEANING THE CARBON DUST FILTER AND HONEYCOMB COOLING MEDIA e The appliance is supplied with a Carbon Dust Filter and Honeycomb Cooling Media e The Carbon Dust Filter and Honeycomb Cooling Media are located inside the Rear Grill See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance e Do not run the unit in COOL mode with stale water in the ank You must empty the water tank and refill with fresh water especially if the tank has not been cleaned in a long ime e The cleaning frequency for the Honeycomb media depends on local air and water conditions In areas where the mineral content of water is
12. rd hour onwards until you switch off the unit FUNCTION BUTTONS CONTINUED TIMER Press the TIMER button until the desired time duration setting is selected When the set time has passed the unit will automatically turn off unit remains in Standby mode until power cord is unplugged from electrical socket The TIMER function allows you to program the unit for up to 7 5 hours of use SWING Press the SWING button until f is illuminated on the display screen HI The louvers will begin to move left to right automatically we Vertical Air Flow You can manually adjust the louvers to change vertical air flow LOUVER MOVEMENT COOL Press the COOL button until amp is illuminated on the display screen This activates evaporative cooling The water pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is completely wet WARNING Please ensure sufficient water is in the water tank otherwise you may hear a Low Water Alarm and the cooler will start in a Fan only mode without evaporative cooling REMOTE CONTROL Power ON OFF Speed Low Medium High Sleep Cool Evaporative cooling ON OFF t Swing Controls the motion of the louvers Timer Controls the Timer function for automatic off Honeywell Applicable for models with Sleep feature only Note e The remote control requires a CR2032 1 x 3V coin type or equivalent battery for replacement
13. structions before use www jmatek com Model CS10XE E mail usinfo jmatek com 14 15 16 1 Display Screen 7 Remote Control 13 Carbon Dust Filter 2 Control Panel 8 Honeycomb Cooling Media 14 Water Level Indicator 3 Louvers 9 Rear Grill 15 Detachable Water Tank Latch 4 Front Grill 10 Water Fill Tray 16 Power Cord amp Plug 5 Drain Plug 11 Water Tank 6 Handle 12 Castors WARNING READ AND SAVE THE AIR COOLER SAFETY amp MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND OR IMPAIR ITS OPERATION AND VOID THE WARRANTY CONTROL PANEL Icons on Display Screen M AE Cool f f Swing H Fan Speed 7 es SL Low T r M Medium Power ON OFF KON Timer Setting H High S Sleep amm haa a Applicable for models with Sleep feature only FUNCTION BUTTONS POWER Press the POWER button to turn the unit on The cooler will start automatically at medium speed After a few seconds the speed will switch to low To turn the unit off press the button again SPEED Press the SPEED button repeatedly to change the speed between H M L S The indicator light will show the selected speed High H gt Medium M Low L lt gt Sleep S When the SLEEP mode is selected the fan will run on High for one hour then Medium for the second hour and on Low speed from the thi
14. tdoor Air Cooler models are designed to IPX4 product standards and not recommended to be placed outdoors during heavy rain or snow WARNING READ AND SAVE THE AIR COOLER GUIDE AND USER MANUAL The Air Cooler Guide and User Manual are intended to provide important information needed to set up operate maintain and troubleshoot your Air Cooler Failure to follow these instructions may damage and or impair its operation create hazards and void the warranty READ AND SAVE THESE INSTRUCTIONS When using electrical appliances basic safety precautions should always be followed e Check the household voltage to ensure it matches the appliance s rating specifications e Before operating the product remove the packaging and check that product is in good condition e DONOT operate with a damaged cord or plug If the supply cord is damaged it must be replaced with a supply cord which is as per manufacturers specifications by the authorized service centre or its service agent or a similarly qualified person in order to avoid a hazard e DO NOT use an extension cord with this unit e DO NOT run power cord under carpeting or cover it with rugs or runners Keep the cord away from areas where it may be tripped over e Always ensure the water tank is filled with water above the min level mark when operating the air cooler in evaporative COOLING mode e Always unplug the Air Cooler before refilling the water tank cleaning servicing or relocating t
15. y you must function is only available on some Honeywell switch off the water supply and remove the drain tube before draining the water tank This Air Cooler models Check the User Manual to see if your unit has the Continuous Water Supply Function e Clean the water tank with a damp cloth to wipe away any dust or mineral deposits e Remove the Honeycomb Cooling Media and fresh water to remove dust and dirt Replace the Honeycomb Cooling Media and e To protect the unit from dust and scratches e Coil the Carbon Dust Filter from the Air Cooler and rinse under Carbon Dust Filter after they are clean and dry cover with a clean cloth or plastic bag before storing power cord and store it away from tl he floor to protect it Carbon Dust Filter is available in specific models of Honeywell Air Coolers only Check the User Manual for your model to see if it includes a Carbon Dust Filter Customer Service Center See the last page of the User Manual to find the contact details for the Customer Service Center for your area PROBLEM No discharge of air Not Cooling Unit is making noise Excessive humidity in the room Odors Remote control does not work The unit does not respond The outdoor Air Cooler is wet from rain POSSIBLE CAUSE Cord is not plugged in Power is not ON Pump is not turned ON Low or no water in tank when COOL is selected Damaged Pump or Calcium
Download Pdf Manuals
Related Search
Related Contents
USER'S GUIDE - Danoz Direct Cub Cadet PR-521 Lawn Mower User Manual Guía de instalación del software Pontiac g8 Automobile User Manual M480−SXXZ Smeg RF1500PC refrigerator Samsung Xpress C460FW Color Multifunction (18 / 4 ppm) User Manual User manual VoIP-TAの取扱説明書(PDFファイル)をダウンロードする Copyright © All rights reserved.
Failed to retrieve file