Home

User Manual for FireWire Range Extender - AV

image

Contents

1. Interfaces and Sync Processors GROUP 5 Twisted Pair Interfaces GROUP 6 Accessories and Rack Adapters GROUP 7 Scan Converters and Scalers and GROUP 8 Cables and Connectors 2 Download up to date Kramer user manuals from the Internet at this URL http www kramerelectronics com manuals html 3 The complete list of Kramer cables is on our Web site at http www kramerelectronics com click Cables and Connectors in the Products section 1 Overview The TP 300FW FireWire Range Extender is based on FireWire which e Is a serial bus standard that enables quick universal interfacing between digital video audio and data and computer hardware items e Is simple to use and operates independently of the host system letting you connect items for extended distances e Supports Plug and Play hot swapping and isochronous and asynchronous applications In particular the TP 300FW e Supports the provisions of the IEEE 1394a 2000 and 1394 1995 Standard for High Performance 1394 Serial Bus e Supports the provisions of the IEEE 1394b 2002 Standard at S100 signaling rates e Enables 1394 100Mbps signals to be transmitted and received across an extended range on unshielded twisted pair cable e Includes built in protection from electrostatic discharge ESD by suppressing all transient high voltages down to the allowed level In particular ESD protection for high speed data lines to IEC 61000 4 2 ESD 15kV air 8kV c
2. first TP 300FW unit to the CAT 5 Straight RJ45 connector on the second TP 300FW unit 2 Alternatively connect the CAT 5 Crossed RJ45 connector on the first TP 300FW unit to the CAT 5 Crossed RJ45 connector on the second TP 300FW unit KRAMER SIMPLE CREATIVE TECHNOLOGY Using Your TP 300FW FireWire Range Extender 5 2 Connecting 2 FireWire Devices via Several TP 300FW Units You can interconnect multiple TP 300FW units to extend the FireWire range Each additional TP 300FW extends the range up to a further 100m For example Figure 4 illustrates how three TP 300FW units may be used to extend the Fire Wire range to 200m To interconnect three TP 300FW units using twisted pair UTP CAT 5 cable commonly used for Ethernet connections do the following 1 Connect a FireWire device for example a video camcorder to the FW PORT on the first TP 300FW unit and a FireWire device for example a PC to the FW PORT on the third TP 300FW unit 2 Connect the CAT 5 Straight RJ45 connector on the first TP 300FW unit to the CAT 5 Crossed RJ45 connector on the second TP 300FW unit and connect the CAT 5 Straight RJ45 connector on the second TP 300FW unit to the CAT 5 Crossed RJ45 connector on the third TP 300FW unit 3 On each TP 300FW unit connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity The ON red LED lights 4 Be sure that the power on each device is turned ON On the first and
3. l i 12V DC CAT5 CAT5 Crossed Straight KRAMER TOOLS KRAMER Firewire Range Extender TP SOOFW ACTIVE FW PORT RESET ON b oo Figure 1 TP 300FW FireWire Range Extender Table 1 TP 300FW FireWire Range Extender Features Feature Function 1 12VDC 12V DC connector for powering the unit 2 CAT 5 Crossed RJ45 Connects to the CAT 5 Straight connector on another TP 300FW unit Connector 3 CAT 5 Straight RJ45 Connects to the CAT 5 Crossed connector on another TP 300FW unit Connector 4 ACTIVE Green LED Lights when a powered and fully functioning FireWire device is connected 5 FW PORT Connects to the FireWire device 6 RESET Button Reboots the setup without having to disconnect and reconnect the power 7 ON Red LED llluminates when receiving power 5 Using Your TP 300FW FireWire Range Extender The standard FireWire range between two FireWire devices is limited to 4 5m 13 5ft as Figure 2 illustrates e Video Camcorder i eo Figure 2 Connecting 2 FireWire Devices Standard 4 5m Range 3 Using Your TP 300FW FireWire Range Extender 5 1 Connecting 2 FireWire Devices via 2 TP 300FW Units You can interconnect a pair of TP 300FW units to extend the FireWire range to up to 100m 300ft as Figure 3 illustrates To interconnect a pair of TP 300FW units using twisted pair UTP CAT 5 cable commonly used for Ethernet conne
4. third TP 300FW units the ACTIVE green LED lights indicating that a cable from an external powered and fully functioning Fire Wire device is connected ravoc Gars CATS ravoc cars CATS rave cats cars oe Crossed Straight o Crossed Straight Crossed Straight KRAMER TOOLS KRAMER TOOLS K KRAMER TOOLS K mA AE LE Firewire Range Extender TP 300FW Firewire Range Extender TP 300FW Firewire Range Extender TP 300FW ACTIVE FWPORT RESET ON AGTIVE FWPORT RESET ON ACTIVE FWPORT RESET ON Figure 4 Connecting 2 FireWire Devices via 3 TP 300FW Units Extended 200m Range 1 Alternatively connect the CAT 5 Crossed RJ45 connector on the first TP 300FW unit to the CAT 5 Straight RJ45 connector on the second TP 300FW unit and connect the CAT 5 Crossed RJ45 connector on the second TP 300FW unit to the CAT 5 Straight RJ45 connector on the third TP 300FW unit 5 Technical Specifications 6 Technical Specifications Table 2 includes the technical specifications Table 2 Technical Specifications of the TP 300FW FireWire Range Extender PORT One 6 pin serial 1394 port 2 RJ45 CAT 5 ports TRANSFER RATE 100Mbps IEEE 1394 STANDARDS IEEE 1394a 2000 IEEE 1394 1995 IEEE 1394b 2002 up to 100Mpbs ESD LINE PROTECTION IEC 61000 4 2 ESD 15kV air 8kV contact IEC 61000 4 5 Lightning 12A 8 20us and IEC 61000 4 4 EFT 40A 5 50n
5. Kramer Electronics Ltd JA KRAMER USER MANUAL Model TP 300FW FireWire Range Extender Contents Contents Introduction Getting Started Overview Your TP 300FW FireWire Range Extender Using Your TP 300FW FireWire Range Extender Connecting 2 FireWire Devices via 2 TP 300FW Units Connecting 2 FireWire Devices via Several TP 300FW Units Technical Specifications D Figures Figure 1 TP 300FW FireWire Range Extender Figure 2 Connecting 2 FireWire Devices Standard 4 5m Range Figure 3 Connecting 2 FireWire Devices via 2 TP 300FW Units Extended 100m Range Figure 4 Connecting 2 FireWire Devices via 3 TP 300FW Units Extended 200m Range Tables Table 1 TP 300FW FireWire Range Extender Features Table 2 Technical Specifications of the TP 300FW FireWire Range Extender DAN ER ni ni m Un R ADDENDUM TP 300FW This addendum clarifies that only SHIELDED CABLES should be used with the TP 300FW and the chronological order in which the TP 300FW should be connected Amendment to Section 3 In the following text e Enables 1394 100Mbps signals to be transmitted and received across an extended range on unshielded twisted pair cable the word unshielded is replaced by shielded Amendment to Section 5 To avoid interference in normal operation be sure to follow the correct order When connecting the TP 300FW FireWire Range Extender connect in the following order 1 Conne
6. and upgraded most of our line making the best even better Our 350 plus different models now appear in 8 Groups which are clearly defined by function Congratulations on purchasing your Kramer TOOLS TP 300FW FireWire Range Extender which is ideal for e Digital video production editing studios and digital video live broadcasting e PC FireWire port extensions and long cable drivers The package includes the following items e TP 300FW FireWire Range Extender e Power adapter 12V DC Input e This user manual and the Kramer concise product catalog CD 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables 3 Overview The high quality Kramer TOOLS TP 300FW FireWire Range Extender is a truly unique product that lets you extend the standard 4 5m 13 5ft FireWire range considerably see Figure 2 For example interconnecting a pair of TP 300FW units see Figure 3 lets you extend the FireWire range to up to 100m 300ft and interconnecting three TP 300FW units see Figure 4 lets you extend the FireWire range to up to 200m 600ft using an inexpensive and widely used CAT 5 cable 1 GROUP 1 Distribution Amplifiers GROUP 2 Video and Audio Switchers Matrix Switchers and Controllers GROUP 3 Video Audio VGA XGA Processors GROUP 4
7. ct to the power using the 12V power supply provided 2 Connect the CAT 5 cable with RJ 45 connectors at both ends 3 Connect the FireWire cables When disconnecting the TP 300FW FireWire Range Extender connect in the following order 1 Disconnect the FireWire cables 2 Disconnect the CAT 5 cable with RJ 45 connectors at both ends 3 Unplug the 12V power adapter Notes e Apply the same rules for both source and destination FireWire equipment that is first connect the power to both TP 300FW units and only then connect the Firewire cables e When reconnecting two TP 300FW units first disconnect the cable and only then reconnect them e Wait 5 seconds after completing all the connections for the picture to appear on the destination device If the picture fails to appear on the destination device after 5 seconds press the RESET Button to reboot the setup Wait another 5 seconds for the picture to appear on the destination device e There is no need to use the Kramer PT 1FW DV Line Protector on the line with TP 300FW units because the TP 300FW already has this technology built in 1 Disconnect in reverse order P N 2900 0003002 Al Introduction 1 Introduction Welcome to Kramer Electronics since 1981 a world of unique creative and affordable solutions to the infinite range of problems that confront the video audio and presentation professional on a daily basis In recent years we have redesigned
8. ctions do the following Connect a FireWire device for example a video camcorder to the FW PORT on the first TP 300FW unit and a FireWire device for example a PC to the FW PORT on the second TP 300FW unit Connect the CAT 5 Straight RJ45 connector on the first TP 300FW unit to the CAT 5 Crossed RJ45 connector on the second TP 300FW unit when using a straight pin to pin cable with RJ 45 connectors If you are using a crossover cable with RJ 45 connectors connect the CAT 5 Straight RJ45 connector on the first TP 300FW unit to the CAT 5 Straight RJ45 connector on the second TP 300FW unit On each TP 300FW unit connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity The ON red LED lights Be sure that the power on each device is turned ON On each TP 300FW unit the ACTIVE green LED lights indicating that a cable from an external powered and fully functioning FireWire device is connected save cars Crossed KRAMER TOOLS Firewire Range Extender ACTIVE cars Straight K TP 300FW FWPORT RESET ON yavpe cars KRAMER TOOLS Firewire Range Extender ACTIVE cars Straight M TP 300FW FWPORT RESET ON es Video Camcorder Figure 3 Connecting 2 FireWire Devices via 2 TP 300FW Units Extended 100m Range 1 Alternatively connect the CAT 5 Crossed RJ45 connector on the
9. fective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for D 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light industry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION gt Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufactu
10. ontact IEC 61000 4 5 Lightning 12A 8 20us and IEC 61000 4 4 EFT 40A 5 50ns To achieve the best performance e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer TP 300FW away from moisture excessive sunlight and dust 1 Originally developed by Apple and published as IEEE 1394 by the Institute of Electrical and Electronics Engineers 2 Hardware items include digital cameras computers printers VCRs CD ROMs hard disks scanners and graphic cards 3 Configures automatically Whenever a device is added or removed the 1394 bus re enumerates 4 You can connect and disconnect inputs and outputs dynamically without having to restart the PC or cycle power 5 Video audio applications require constant transfer rates which the serial bus provides by supporting isochronous transfers 6 Often when connecting a live DV source to a receptor an electrical potential difference or any other element creating a high voltage such as ESD or a live chassis may permanently damage one or both of the connected devices This high voltage may be seen as a spark occurring at the instant of connection or may not be seen at all but nevertheless can result in costly damage KRAMER SIMPLE CREATIVE TECHNOLOGY Your TP 300FW FireWire Range Extender 4 Your TP 300FW FireWire Range Extender Figure 1 and Table 1 define the TP 300FW FireWire Range Extender I
11. ramer iv Any shipment of the product claims must be presented to the carrier v Removal or installation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removal or installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center De Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any ef
12. rer will void user authority to operate the equipment gt Use the supplied DC power supply to feed power to the machine gt Please use recommended interconnection cables to connect the machine to other components 7 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com Updates to this user manual may be found at http www kramerelectronics com manuals html We welcome your questions comments and feedback 001 Oo Institute of Quality amp Control Kramer Electronics Ltd Web site www kramerelectronics com E mail info kramerel com P N 2900 000300 REV 1
13. s POWER SOURCE 12 VDC 60mA DIMENSIONS 12cm x 7 5cm x 2 5cm 4 7 x 2 95 x 0 98 W D H WEIGHT 0 3 kg 0 67 Ibs approx ACCESSORIES Power supply mounting bracket 1 Specifications are subject to change without notice 6 KRAMER SIMPLE CREATIVE TECHNOLOGY LIMITED WARRANTY Kramer Electronics hereafter Kramer warrants this product free from defects in material and workmanship under the following terms HOW LONG IS THE WARRANTY Labor and parts are warranted for three years from the date of the first customer purchase WHO IS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by Kramer or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the web site www kramerelectronics com Any product on which the serial number has been defaced modified or removed Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by K