55PGPORT User Manual

image

Contents

1. screenshot or string together with new Customer PC Code when applying for new Software License Key without purchasing the new license in situations when it is necessary to move Klinkmann software to other computer or operation system change is planned Note Without providing the Software License Key removal message screenshot or string the new Software License Key will not be assigned S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 10 Installing the I O Server Infrastructure The I O Server Infrastructure installation package is supplied as a self extracting archive lOServerInfrastructure exe and can be downloaded from Klinkmann s web site To install the I O Server Infrastructure from the self extracting archive run the lOServerlnfrastructure exe and proceed as directed by the I O Server Infrastructure Setup program To uninstall the I O Server Infrastructure start Control Panel select Add Remove Programs and select the IO Server Infrastructure from the list of available software products Click on Add Remove and proceed as directed by the UnIinstallShield program Note The I O Server Infrastructure installation will be rejected if Wonderware FS2000 Common Components are already installed on same computer S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Commu
2. start SSPGPORT Server and check if Sofware key or HASP HL key not found message does not appear then it means everything is done correctly and S5PGPORT Server runs in full mode with licensing by HASP HL key enabled Software license key GSM Control supports the computer dependent software licensing The following steps are required to enable it 1 Start SSPGPORT Server click on Help menu item also short cut Alt H can be used and pop up menu with Help menu commands will appear Contents License About SSPGPORT Select License and License dialog will appear x Product Code DRI 6010149 Customer PC Code at 4a b075 4921 dabe Software Key Cancel T 2 Here the Customer PC Code is computer dependent string generated by S5PGPORT Server and it is unique for this computer Write it down or Copy Paste to e mail when ordering the SSPGPORT Server 3 After purchasing the SSPGPORT Server you will get the software license key 16 character alphanumeric string Open the License dialog again and Copy Paste it to Software Key field S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 8 TT x Product Code DRI 6010149 Customer PC Code ai 4a b075 4921 dabe Transfer Software Key bat3 1 16fd c5d 0626 Cancel 4 Click OK and restart SOPGPORT Server SOPGPORT Server software lice
3. DB10DL20 data block 10 left byte of data word 20 value in the PLC is binary and has a range of 0 to 255 DB10DW20KF data block 10 data word 20 value in the PLC is binary and has a range of 32768 to 32767 DB10DW20BCD data block 10 data word 20 value in the PLC is in BCD format and has a range of 0 to 9999 DB10DS20 8 data block 10 value in the PLC is character string containing 8 bytes and starting at data word 20 DB10DW20KC data block 10 data word 20 value in the PLC is in counter constant format and has a range of 0 to 999 DB10DW20KT data block 10 data word 20 value in the PLC is in timer constant format and has a range of 0 0 to 999 3 S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 21 FB100 flag byte 100 value in the PLC is binary and has a range of 0 to 255 FW100BCD flag word starting at flag byte 100 value in the PLC is in BCD format and has a range of 0 to 9999 132 0 bit O of input byte 32 TWOBT timer word 0 value in the PLC is in binary timer format CW10BC counter word 10 value in the PLC is in binary counter format ASS5F00 10 value in the PLC is character string containing 10 bytes and starting at absolute address 5F00 Hex ASB_5F_BCD value in the PLC is byte BCD format and starting at absolute address 5F Hex DB1DD13KG data block 1 data double word 13 value in the PLC is in floating point format Monitoring and
4. Item Names section later in this manual S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 4 Installing the SOPGPORT Server Installing the Server The SSPGPORT Server installation package is supplied as a Microsoft Installer file DR16010_xxx msi for Suite Link amp DDE version or DR16011_xxx msi for OPC amp DDE version where xxx is the current latest version of SOPGPORT Server To install the SSPGPORT Server run the DR16010_xxx msi for Suite Link amp DDE version or DR16011_xxx msi for OPC amp DDE version and proceed as directed by the S5PGPORT Server Setup Wizard The installation is simple and straightforward only it is important to select the correct protection HASP key or software license in Custom Setup dialog The HASP key or software license key is needed for full time running of SOPGPORT Server The HASP key is an USB key dongle to be installed into PC USB port and needs the SafeNet Sentinel LDK Run time Environment HASP HL Runtime Package to be installed and running see details in Licensing by using HASP HL key section below The software license key is a 16 character alphanumeric computer dependent string provided after purchasing the SSPGPORT Server for more information see Software license key section below Without HASP key installed or software license key entered the SSPGPORT Se
5. Monitoring the Status of Communication with INTOUCH cccceeeeeeeeeeeeeeeeeeeeeeeees 33 Notes on Using Microsoft EXC faiiss 25cone cezgaetctussegtuccs Satvne islet eentctetaezckeseunteligtoeetcietewends 33 Reading Values into Excel Spreadsheets ccccceeeeeeseeeeceeeeeeeeeeeeeeeseeeeeeeeeees 33 Writing Values to SSPGPORT Points cececeeeeeeeeeeeeeeeeeeeeeeeeeeeeeceeeeeeeeeeeeeeeeeee 34 Troubleshooting 2 5h ta ota Alen atin Ala al ein Seal ints La nal Co A a AN LAA Ea 35 WINING VO ose cp cued eee ceantatatad A A AA Ceeeswen ease 35 SlanuUpSSQuenCe MS Vals scesie cya cuetcxescvei pug se oustckas ciate eed he sceet pha teka egvabes tatekec eevee 35 SlowPollRetries and SlowPolllnterval ccccceeeeeeeeeeeeneeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 35 WriteRetrylndefinitely ia 232tcccte cased iadecattciicehichticatd ctecehs bi catt aoc cedd tds chttents eit aahs ds 36 ShowAllRejecteAwrites cccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeedeaaeeeeeeeeeeeeeeeeenaaeeeeeeeeeeeeeees 36 THOUBIESNOOHMG Men s lees cacztelastestalacecstacevect nda AA a A A 36 Internal Logger a a ae ae a tem tra tok a aa aaa e E EEE E 37 S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 1 S5PGPORT Communication Server Overview The SSPGPORT Communication Server hereafter also referred to as the SSPGPORT Server or SSPGPORT or Server
6. is a Microsoft Windows 32 bit application program that acts as a communication protocol Server and allows other Windows application programs access to data from SIEMENS SIMATIC S5 Programmable Logic Controllers S5 95U S5 115U S5 135U S5 155U Sinumerik 840C using SIMATIC S5 Programming Port Interface AS511 Any Microsoft Windows program that is capable of acting as a DDE FastDDE SuiteLink or OPC Client may use the SOPGPORT Server There are two different SSPGPORT Server versions described in this manual Server version ordering number DR 160 10 supporting SuiteLink FastDDE and DDE protocols this version hereafter is referred to as the Suite Link amp DDE version Server version ordering number DR 160 11 supporting OPC and DDE protocols this version hereafter is referred to as the OPC amp DDE version The separate installation package is supplied for each version of the Server In all cases the name of Server executable file is SSPGPORT EXE All further information in this manual is same for all versions of the Server with the exception of few points where communication protocol specific features are explained Communication Protocols Dynamic Data Exchange DDE is a communication protocol developed by Microsoft to allow applications in the Windows environment to send receive data and instructions to from each other It implements a client server relationship between two concurrently running applications Th
7. the Disk Options dialog box will appear File Options Directory Ic Program Files x86 Klinkmann Automation Keep Log File for jo days The following can be entered in this dialog box Log to File If checked then Internal Logger information will be saved to Internal Logger file The S5PGPORT Internal Logger file name is created in the following format S5PGPORT _YYYYMMDD LOGn where YYYY is a year MM is a month DD is a day and n is a order number of S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 38 consecutive SSPGPORT Internal Logger file starting from 1 The SSPGPORT Internal Logger file maximum size is 16 MB if there is more information logged then next consecutive file is created e g there can be consecutive files S5PGPORT_20030228 LO0G1 SSPGPORT_20030228 LOG2 etc Directory Enter the path where to keep the Internal Logger File Keep Log File for Here the number of days how long to keep the Internal Logger File can be entered After this number of days expires the corresponding Internal Logger File will be automatically deleted The default value 0 keeps Internal Logger Files forever in this case they can be deleted manually S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 39 Oct 95 Rev 1 0 Nov 95 Aug 97 Dec 97 Mar 98 Sep 98
8. Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 2 compatible computers connected via LAN or modem and DDE aware applications running on non PC based platforms under operating environments such as VMS and UNIX SuiteLink uses a TCP IP based protocol and is designed by Wonderware specifically to meet industrial needs such as data integrity high throughput and easier diagnostics This protocol standard is only supported on Microsoft Windows NT 4 0 or higher SuiteLink is not a replacement for DDE FastDDE or NetDDE The protocol used between a client and a server depends on your network connections and configurations SuiteLink was designed to be the industrial data network distribution standard and provides the following features Value Time Quality VTQ places a time stamp and quality indicator on all data values delivered to VTQ aware clients Extensive diagnostics of the data throughput server loading computer resource consumption and network transport are made accessible through the Microsoft Windows NT operating system Performance Monitor This feature is critical for the scheme and maintenance of distributed industrial networks Consistent high data volumes can be maintained between applications regardless if the applications are on a single node or distributed over a large node count The network transport protocol is TCP IP using Microsoft s standard WinSock int
9. Entering slow poll mode on topic lt TOPICNAMEs gt on port lt PORTNAME gt If all topics for some port are in slow poll mode then after 5 full slow poll cycles all topics are at least 5 times polled this port is closed and reopened again S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 36 Leaving the slow poll mode is reported to WWLogger and or to SOPGPORT Internal Logger by following string Leaving slow poll mode on topic lt TOPICNAME gt on port lt PORTNAME gt after d seconds WriteRetryIndefinitely The WriteRetrylndefinitely entry is used to disable the deleting of pending write messages when slow poll mode is started As default no WriteRetrylndefinitely entry in WN INI or WriteRetrylndefinitely 0 all write messages for this topic are deleted when topic enters the slow poll mode To disable this the following entry can be used WriteRetryindefinitely 1 Note Be careful when using this setting if PLC is switched off but client application continues to generate new values to be written to this PLC it can cause the computer memory overfill with memory allocated for write messages ShowAllRejectedWrites The ShowAllRejectedWrites entry is used to enable the logging of rejected write messages This option can be useful when communication with a separate topic PLC is suspended by SUSPEND item see Item Names section and the Server rejects eac
10. Server uses an item point naming convention based on the two letter data type identifiers used to program Siemens PLCs The following data areas are supported Data Blocks Extended Data Blocks Flags Inputs Outputs Counters Timers Absolute Address All PLC data areas are accessed by absolute addresses These addresses are determined when Server opens the communication on PC serial port The Server reads start addresses of Flags Inputs Outputs Counters Timers Data Blocks and Extended Data Blocks For Data Blocks and Extended Data Blocks the Server also reads the block size These values are used to validate the item names All other data areas are accessible as absolute addresses which can be found in the PLC manual Note If the PLC program changes at runtime the location and length of Data Blocks physical addresses of data then the Server cannot determine this situation and continues to work with old values Note In the current Server version for Sinumeric 840C PLCs the writing reading is supported only to from Data Blocks and Extended Data Blocks If for example writing reading is required to flag area then corresponding fragment must be included in the PLC program which will transfer values from data block to flag area or vice versa The general syntax of item name is Prefix Type modifier _ address _ suffix where Prefix determines data area type and data block number for Data Blocks
11. computer The License dialog now will contain the empty Customer PC Code and Software Key fields S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server x Product Code DR16010 149 Customer PC Code 0000 0000 0000 0000 Software Key Cancel 3 Take the screenshot from ArchestrA SMC Logger or SSPGPORT Internal Log file window containing the Software License Key removal message like below Message Details x No 57658899 Date 2013 02 Time 13 28 50 Message Software Key 4d73 626e 4f2d e126 removed PC Code b12b b075 1e20 da91 Product Code DR16010 149 B Lister c Program Files x86 Klinkmann Automation S5PgPort OPC Server S5PGPORT_20130228 log 5 x File Edit Options Encoding Help 70 2013702728 13 43 34 416 SSPGPORT Software Key 4d74 626c 3f25 e126 removed PC aj Code b12b b675 1e26 db91 Product Code DR16011 149 2013 62 28 13 43 34 463 SSPGPORT HASP HL Error 7 Sentinel HASP protection key a not available 2613 62 28 13 43 34 474 SSPGPORT HASP HL key not found or take the string with Software License Key removal message directly from ArchestrA SMC Logger or SSPGPORT Internal Log file like following Software Key 4d73 626e 4f2d e126 removed PC Code b12b b075 1e20 da91 Product Code DR16010 149 Provide the obtained Software License Key removal message
12. directory e g C WINNT It is an ASCII file and can be altered manually if you wish with any text editor e g MS Windows Notepad do not use a program that formats text such as MS Word or Write unless the file is saved as DOS text The following is a typical entry for the SSPGPORT Server S5PGPORT Winlconic 0 WinFullScreen 0 WinTop 126 WinLeft 548 WinWidth 414 WinHeight 144 There are following additional WIN INI entries available for SOPGPORT Server StartupSequencelnterval The StartupSequencelnterval entry is used to enter the number of seconds between executions of startup sequence see Running the SSPGPORT section SlowPollRetries and SlowPolllnterval The SlowPollRetries entry is used to enter the number of consecutive error retries for one topic PLC If after SlowPollRetries there is still no successful response from PLC then this topic is changed to slow poll mode The WIN INI file SlowPollinterval entry is used to enter the slow poll mode update interval in seconds The default values they are used if WIN INI file does not contain these entries are SlowPollRetries equal to 5 and SlowPolllnterval equal to 60 seconds For example the following entries can be used to specify that slow poll mode 2 minutes will start after 3 consecutive unsuccessful retries SlowPollRetries 3 SlowPolllnterval 120 Entering into slow poll mode is reported to WWLogger and or to SOSPGPORT Internal Logger by following string
13. drive Location C Program Files x86 Klinkmann Automation SSPgPort Browse Suitelink Server Reset Disk Usage Back net canei Note In case the SafeNet Sentinel LDK Run time Environment HASP HL Runtime Package is already installed on your computer separately or by some other software then it can be disabled Click the icons in the tree below to change the way features will be installed EEI HAsP Device driver Sentinel LDK Run time Environment J HASP Files HASP HL Runtime Package This feature requires OKB on your hard drive When installation is finished the subdirectory specified as a folder where to install the S5PGPORT Server files will contain the following files S5PGPORT EXE The SSPGPORT Server Program This is a Microsoft Windows 32 bit application program S5PGPORT CHM The SSPGPORT Server Help file S5PGPORT CFG An example configuration file S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 6 hasp_windows_44 Dynamic Link Library installed only if HASP Files is selected 42 dll during the installation in Custom Setup dialog haspdinst exe Sentinel LDK Run time Environment Installer HASP HL Runtime Package copied to SOSPGPORT Server folder only if HASP Device driver is selected during the installation in Custom Setup dialog LICENSE RTF Klinkmann Automation software licen
14. in quotation marks POKE channel itemname Data_Reference POKEs the value contained in the Data_Reference to the specified item name actual location in the Simatic S5 PLC via the channel number returned by the previously executed INITIATE function Data_Reference is the row column ID of the cell containing the data value For itemname use some of the valid item names specified like described in the Item Names section TERMINATE channel Closes the channel at the end of the macro Some applications have a limited number of channels Therefore they should be closed when finished Channel is the channel number returned by the previously executed INITIATE function RETURN Marks the end of the macro The following is an example of Excel macro used to poke value from cell B2 to topic PLC1 item DB20DW30 PokeMacro Ctrl a INITIATE SS5SPGPORT PLC1 POKE A2 DB20DW30 B2 ON TIME NOW 0 01 TerminateDDEChannel RETURN TerminateDDEChannel TERMINATE A2 RETURN Note Refer to the Microsoft Excel manual for complete details on entering Remote Reference formulas for cells S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 35 Troubleshooting WIN INI entries The first time you run the SSPGPORT Server configuration most of the items in the following list will automatically appear in the WIN INI file located in the MS Windows system
15. 060 The FastDDE Version 2 and DDE support for SSPGPORT Server OPC amp DDE version is implemented by Wonderware I O Server Toolkit ver 5 0 008 S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 3 Accessing Remote Items via the Server The communication protocol addresses an element of data in a conversation that uses a three part naming convention that includes the application name topic name and item name The following briefly describes each portion of this naming convention application name The name of the Windows program server that will be accessing the data element In the case of data coming from or going to SIMATIC S5 PLCs via this Server the application portion of the address is SSPGPORT topic name Meaningful names are configured in the Server to identify specific devices PLCs These names are then used as the topic name in all conversations to that PLC The S5PGPORT Server considers each SIMATIC S5 PLC to be a separate topic For example S95U Note You can define multiple topic names for the same PLC to poll different points at different rates item name A specific data element within the specified topic For the SSPGPORT Server an item is an individual data bit byte word timer etc in the PLC The term point is used interchangeably with the term item in this User Manual For more information on item point names see the
16. 999 B Byte None Integer 0 to 255 L Left Byte h n 0 to 7 Discrete Oor1 R Real Floating point KG S String sn sn 2 to 32 Even length from 2 to 32 Where n the bit position in item sn the length of string in bytes sn must be even number from 2 to 32 S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 20 Suffix BC is used if it is necessary to view a counter value directly There is no sense to use this suffix for other data areas except counters Suffix KC is used to view counter values transferred to other data areas e g Data Blocks by means of LD and T STEP 5 operations There is no sense to use suffix KC together with counter prefix The counters without suffix and type modifiers are assumed as with suffix BC and W type modifier Suffix BT is used if it is necessary to view a timer value directly There is no sense to use this suffix for other data areas except timers Suffix KT is used to view timer values transferred to other data areas e g Data Blocks by means of LD and T STEP 5 operations There is no sense to use suffix KT together with timer prefix T The timers without suffix and type modifiers are assumed as with suffix BT and W type modifier Item Naming Examples This section provides some examples of item names where the correct format is used DB10D20 15 data block 10 bit 15 of data word 20
17. Controlling Communication with a PLC For each topic there are following additional items offered by SSPGPORT Server to monitor and control the communication with PLC STATUS For each topic there is a built in discrete item that indicates the state of communication with PLC The discrete item STATUS is set to 0 when communication fails and set to 1 when communication is successful The STATUS value is set to 0 after 3 consecutive unsuccessful retries to communicate with this PLC From InTouch the state of communication may be read by defining an I O Discrete tagname and associating it with the topic configured for the PLC and using STATUS as the item name S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 22 From Excel the status of the communication may be read by entering the following formula in a cell S5PGPORT topic STATUS UPDATEINTERVAL The UPDATEINTERVAL item is an Integer type Read Write item used to access the currently set Update Interval see Topic Definition Command section It indicates the current requested update interval in milliseconds The value of this item can be read through DDE Suite Link or OPC Client can poke new values to this item The range of valid values is from 10 to 2147483647 milliseconds The value of zero indicates that no items on this topic are updated The write commands are still executed new values written to PLC if
18. Dec 98 May 99 Jan 2001 Mar 2002 May 2002 Oct 2002 Rev 1 1 Rev 1 2 Rev 1 3 Rev 1 4 Rev 1 5 Rev 1 6 Rev 1 7 Rev 1 8 Rev 1 9 Rev 1 10 Rev 1 11 KLINKMANN AUTOMATION S5PGPORT Communication Server Revision History First Release Minor modifications in the manual Minor changes Manual file name changed Minor changes Bitmaps modified Sinumerik PLC support added Startup sequence processing added 32 bit version supports separate thread for each communication port Suite Link support added Installing the Server section changed New items for monitoring and controlling communication with a PLC added User manual layout changed Modifications in the manual text OPC support added OPC compliance information added Installation from CD information added Suffix KG supported for all PLC types Installing the SSPGPORT Server section modified Licensing by using HASP HL key and Software license key sub sections added Internal Logger section added S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112
19. PORT Server There are following important fields on the OPCLink Topic Definition dialog box Topic Name Enter a unique name e g PLC1 for the PLC in this field If using InTouch then same Topic Name is to be entered in the Add Access Name dialog box when defining the Access Names for OPCLink Server in InTouch WindowMaker OPC Server Name Select the name of the OPC server SSPGPORT OPC_Server that will be used by this topic The list box shows the registered OPC servers in the system OPC Path Enter the name of the OPC path e g S95_1 used by this topic This OPC path is the first part of a full OPC item name string common to all items that will be used in this topic The available OPC paths for SOPGPORT Server can be obtained by clicking on Browse button this allows to view the SSPGPORT Server s exposed address space Update Interval S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 27 Enter the frequency in milliseconds that the server will acquire data for the items points associated with this topic If 0 zero is entered here OPCLink will not gather data from S5PGPORT Server Browse Clicking on this button initiates the browsing through exposed address space of S5PGPORT Server All currently available item point names including data area names and range of addresses and names of pre defined additional items will appear on Brow
20. S5PGPORT Communication Server for Microsoft Windows and Wonderware Applications User Manual Ver 1 x Rev 1 12 DR 160 10 DR 160 11 KLINKMANN AUTOMATION P O Box 38 FIN 00371 Helsinki Finland tel int 358 9 5404940 fax int 358 9 5413541 www klinkmann com Klinkmann Automation SSPGPORT Communication Server i Table Of Contents OVGINIOW scar canriatati octane E T ila e clear tahoe slates tatoo E a 1 Communication Protocols 2c ccs tcctutiecit ia Menta chile telat d ceddiehd Allee tha cad ddebi dele tales nenene nnne 1 Accessing Remote Items via the Servet ccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeseecaaeeeeeeeeeeeeeeees 3 Installing he SSPGPORT Ser Gh aces creas crete ea cesees ss ces eace e A e aai 4 Installing the SOV CN osso8cgccnts near easstes npsghee E A A AEE 4 Licensing by using HASP HL key ecceeeeeeeeeecceeccceeeeeeeeeeeeeaeeeeeeeeeeeeeenenaeeeeeeeeeeeeneee 7 Software license KEW onc ctccist ies cc the Andee tet ita tgeddel sects eit a eb atihd led Acetate lances 7 Transferring the software license to other computer ccceeeeeeeeeeeetteeeeeeeeeeeeeeee 8 Installing the I O Server Infrastructure ccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeenaeeeeeeeeeeeeeeees 10 Connection CADIS sy irk eat AN RE ee AE Aaa aa d ttt RE ee a Raa ek eke ee 11 Configuring the SOPGPORT Server cceeeeeeeescceeeeeeeeeeeeseaaeeeeeeeeeeeeeesenaaeeeeeeeeeeeeeeee 12 Server Settings ComMmaNd snesena aa E a
21. SSPGPORT Server to find the configuration file automatically each time it is started Configuration File Location When the SSPGPORT Server starts up it first attempts to locate it s configuration file by first checking the WIN INI file for a path that was previously specified If the path is not present in the WIN INI file the Server will assume that the current working directory is to be used To start the Server from an application directory configuration file other than the default configuration file a special switch d is used For example invoke the File Run command in File Manager or Program Manager and enter the following S5PGPORT d c directoryname Note There is no limit to the number of configuration files that may be created although each must be in a separate directory S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 16 Topic Definition Command The user provides each connected Simatic S5 PLC with an arbitrary name that is used as the Topic Name for all references to this PLC The following steps are taken to define the Topic attached to the PLC 1 2 Invoke the Configure Topic Definition The Topic definition dialog box will appear Topics ST z reese oe New Modify Delete To modify an existing topic select the topic name and click on Modify To define a new topic click on New The S5PGPORT Topic Defin
22. UPDATEINTERVAL value is 0 Note By poking a value of zero to the UPDATEINTERVAL item a client can stop all update activities on the corresponding topic without having to deactivate the items MAXINTERVAL The MAXINTERVAL item is an Integer type Read Only item used to access the measured maximum update interval in milliseconds of all items for the corresponding topic for the last completed poll cycle The range of valid values is from 0 to 2147483647 milliseconds The UPDATEINTERVAL and MAXINTERVAL items can be used to tune the performance of communication ITEMCOUNT The ITEMCOUNT item is an Integer type Read Only item used to access the number of active items in the corresponding topic The range of valid values is from 0 to 2147483647 ERRORCOUNT The ERRORCOUNT item is an Integer type Read Only item used to access the number of active items with errors in the corresponding topic The range of valid values is from 0 to 2147483647 ERRORITEMS The ERRORITEMS item is an Integer type Read Write Only unique for each topic used to access the total number of items with invalid item names these items are rejected by Server and items with valid names but with non existing address in PLC these items are active but their quality is set to NO ACCESS The ERRORITEMS value can be reseted by writing 0 to this item The range of valid values is from 0 to 2147483647 WRITECOUNT The WRITECOUNT item is an Integer type Read Only item used to ac
23. Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 25 Now remote OPC Server is accessible for OPC Client on computer SteveL To allow the access to more OPC Clients configure DCOM on each OPC Client computer The following table contains most frequent errors when configuring DCOM Error message Possible reason DCOM not installed DCOM has not been installed Server execution failed 1 OPC Server can not be started 2 Identity for OPC server not properly configured 3 OPC Server is not located on a local hard disk 4 OPC Server path in registry is too long or uses LFN Long File Names 5 DCOMCNFG Location is not set to Run on this computer Class not registered OPC Server has not been registered RPC server is unavailable 1 Remote Procedure Call service is not running on the OPC Server computer 2 Invalid computer name for remote OPC Server 3 Make sure TCP IP is installed properly Interface not supported 1 Permission not granted to OPC Client 2 Guest account disabled Access is denied 1 DCOM security not configured properly 2 OPC Server application not located on local hard disk 3 SYSTEM account in DOOMCNFG must have Access Launch and Configure privileges Error 80070776 Network error TCP IP has not been configured properly Catastrophic failure 1 Trying to access an object before it is created 2 Unhandled exception is occurs on the OPC Server Not enough storage SYSTEM a
24. a EE eee ca canes 12 Com Port Settings Command 556 occa eeeidece eed cee eee epic ted deve tee ped gece cd peat nennen 14 Saving SSPGPORT Configuration File accnanccawenainaahiauana cena n 15 Configuration File LOCanO tiie sO ee te ae i a ca Mata 15 Topic Definition Command scotia seecoeer rts anaconda ees cecces eee 16 Running the SSPGPORT Servain aaa AE E Ea 17 tem NAMES esate the p i a a i a i aaie 18 Item Naming EXaMpleS ts con anita nea A ee nh D aaa 20 Monitoring and Controlling Communication with a PLC ccceeeeeeeeeeeeeeeeeeeeeeeees 21 Using the SSPGPORT Server with OPC Clients ccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaaeees 23 COMiQuIInG DC OM A 24 Running SSPGPORT OPC amp DDE version as Windows NT Service 00000 25 Using SSPGPORT with OPCLink Server ccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeesseseneaeeeeeeees 26 OPCEINK TOPIC DERIMMEOM casio esd ects ated eacesmes sree cnce eae Uecaetance E cosines Uncceverayecesnst 26 Accesing SSPGPORT Items via the OPCLink Serve cccceceeeeeeeeeeteeeeeeeeeeeeeees 27 Using the SSPGPORT Server with Suite Link and DDE Clients cccccceeeeeeeeeeeeees 28 Using the SSPGPORT Server with INTOUCH ccceeeeeeeeeseeeeeeeeeeeeeeeeeeseeeeeeeeeeeeeees 28 Defining the Access Names sccm ese cece eee ese esa inde dn sa Sede caidas cee eee 28 Defining the Tag Names sisi hc ates ota a ea Nat ata sta Mata a la ata Tee 30
25. and Extended Data Blocks Type modifier determines data size in bytes and location used to separate address from suffix and prefix or type modifier useful for absolute address to prevent the interpretation of hexadecimal digits as prefix or vice versa address determines item number or address suffix determines type of item and data conversion S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 19 There are following Prefixes Type Modifiers and Address Ranges available Type Modifiers Address Range Data blocks DBbD W L R D S 0 to length of block Ext data blocks DXbD W L R D S 0 to length of block Cc T inputs _ _BW 0 s Outputs B W D S Counters None W Timers None W Absolute B W D S OtoFFFF 0 to FFFFF address L R W D 0 to FFFF Where b Data Block or Extended Data Block number B W D S Notes 1 Underlined Type modifiers are default 2 for PLC S5 135U 3 for PLC S5 115U and S5 155U There are following Suffixes available Type Description Suffix Tag Modifier Type W Word None Integer 0 to 65535 n n 0 to 15 Discrete Oor1 BCD Integer 0 to 9999 KF Integer 32768 to 32767 KC BC Integer 0 to 999 BT KT Message 0 0 to 999 3 Right Byte BCD Integer 0 to 99 KF Integer 128 to 127 Double word None Integer 2147483648 to 2147483647 n n 0 to 31 Discrete Oor1 BCD Integer 0 to 99999
26. capability of running applications even when a user is not logged on to the system This is valuable when systems must operate in an unattended mode Enabling this option and rebooting the system will cause the Server to run as a Windows NT service However to view configuration information or to reconfigure the Server the user must log on to the system Any Server related problems that may arise such as missing adapter cards licensing failures or device drivers not loading will not be visible to the user until a log on is performed Disabling this option and rebooting the system will cause the Server to run as a Windows NT application program once again Notes 1 The Start automatically as Windows NT Service feature can be activated only with SSPGPORT Server Suite Link amp DDE version To start the SSPGPORT Server OPC amp DDE version as Windows NT Service refer to Running SSPGPORT OPC amp DDE version as Windows NT Service section of this manual 2 The Service Startup configuration can be changed by MS Windows NT Control Panel Services configuration dialogs The Allow Service to Interact with Desktop checkbox in Service dialog box must be checked the Service dialog box can be invoked by pressing the Startup button on Services dialog box when Service S5PGPORT_lOServer is selected If Allow Service to Interact with Desktop is not selected then SSPGPORT Server full functionality is not ensured e g th
27. ccount in DOOMCNFG must have Access Launch and Configure privileges Running SSPGPORT OPC amp DDE version as Windows NT Service To install SOPGPORT Server OPC amp DDE version to run as Windows NT Service the S5PGPORT Server must be started with command line parameter Service S5PGPORT Service After this the SSPGPORT OPC amp DDE Server NT Service will be installed with Startup type Manual The Service Startup configuration can be changed by MS Windows NT Control Panel Services configuration dialog boxes The Allow Service to Interact with Desktop checkbox in Service dialog box must be checked the Service dialog box can be invoked by pressing the Startup button on Services dialog box when Service S5PGPORT OPC amp DDE Server is selected If Allow Service to Interact with Desktop is not selected then SSPGPORT Server full functionality is not ensured e g the Server configuration can not be changed no message boxes will be displayed etc To use SSPGPORT Server OPC amp DDE version as Windows NT Service you may need S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 26 to configure DCOM For details of configuring DCOM refer to Configuring DCOM section of this manual If SSPGPORT OPC amp DDE Server NT Service will be accessed only from local OPC clients i e SOPGPORT Server will
28. cess the number of write commands messages waiting for execution The range of valid values is from 0 to 2147483647 S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 23 For example in following way the WRITECOUNT item can be used to avoid the increasing of memory occupied by not executed write commands activate the hot link with WRITECOUNT item and start to monitor it activate new write command by poking new value only if value of WRITECOUNT becomes equal to 0 e g all previous write commands are executed and memory occupied by them is freed SUSPEND Special Read Write Discrete Item SUSPEND may be used to control the communication with a separate topic If application changes SUSPEND value from 0 to 1 then communication with topic is suspended If SUSPEND value is changed back to 0 then communication with this topic is resumed Note If topic is suspended by setting SUSPEND value to 1 then Server rejects all new write values to this topic i e no new write messages are created after SUSPEND value has changed from 0 to 1 Using the SOPGPORT Server with OPC Clients The OPC amp DDE version of SOSPGPORT Server is accessible from OPC Clients There are following general steps needed to access an OPC item from SSPGPORT Server 1 Run OPC Client application and select the SSPGPORT OPC and DDE Server from the list of available OPC Servers I
29. ctionary command in WindowMaker The Tagname Dictionary dialog box will appear Tagname Dictionary x C Main Details Alarms Details amp Alarms Members HEW Restore Delete Save 4 le x Cancel Close Tagname 0832 7 4 Memory Integer Group Svstem C Readonly Readtwrite Comment I LogData I Log Events Tl Retentive Value Retentive Parameters Click on New and enter the Tagname The tag name defined here is the name InTouch will use The SSPGPORT Server does not see this name Select the tag type by clicking on the Type button The Tag Types dialog box will appear S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 31 Memory Discrete 1 0 Discrete Indirect Discrete Memory Integer v 1 0 Integer Memory Real 1 0 Real Indirect Analog Memory Message I O Message Indirect Message Group Var Hist Trend Tag ID To access SSPGPORT items the type must be I O Discrete I O Integer or I O Message Select the Tag type The Details dialog box for the tag name will appear Initial Value fo Min EU fo Max EU 9999 Deadband fo Min Raw f0 Max Raw 9999 Eng Units o com aj Linear Square Root ltem I Use Tagname as Item Name Log Deadband fo Select the Access Name for SSPGPORT Server by clicking on the Access Name button The Access Names dialog box will a
30. d with this serial port is activated So if PLC is connected and ON then there are no problems the startup sequence is read from PLC obtained information is used to validate item names and to create read and write commands and normal communication process starts The situation is different if at serial port opening time the PLC is not connected or switched OFF In this case the Server cannot execute this startup sequence If correct startup Sequence can not be executed then topic is not rejected but only topic STATUS is marked as bad All valid item names also are accepted There is following setting available in the WIN INI file SSPGPORT section used to specify the slow poll mode in seconds at which the startup sequence is repeated for example the following setting StartupSequencelnterval 600 specifies that Server executes startup sequence each 10 minutes The default value of StartupSequencelnterval is 300 5 minutes After startup sequence is executed all items in corresponding topics are verified and information about invalid items is logged to WWLogger and or to SSPGPORT Internal Logger Controlling the computer resources For the SSPGPORT Server the separate thread is used for each communication port so there is no need to check how the Server uses computer resources S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 18 ltem Names The SSPGPORT
31. e Server configuration can not be changed no message boxes will be displayed etc Once all entries have been made click on OK S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 14 Com Port Settings Command This command is used to configure the communication port that will be used to communicate with Simatic S5 PLC Invoke the Configure Com Port Settings command The Communication Port Settings dialog box will appear Communication Port Settings x Com Port com 7 m Target PLC 135U CPU 922 928 928B Data Wait Timeout eoo ms C 115U CPU 945 155U CPU 946 947 Saye Remaining CPU s Defaults C Sinumerik 840C Baud 9600 Data bits 8 Parity Even Stop bits 1 The following describes each field in this dialog box Select the Com Port and examine the characteristics of the selected Port To select a necessary Com Port click on the combo box button and make your choice from the list box Reply Timeout This field is used to enter the amount of time in seconds the Simatic S5 PLC using the selected communication port will be given to reply to commands from the Server Also the horizontal scroll bar below this field can be used to change the entered value Note The default value of 3 seconds should be sufficient for most configurations Target PLC The S5PGPORT Server can handle the complete list of SIEMENS Simatic S5 PLC
32. e needed to run the SSPGPORT Server and these infrastructure files must be install prior to executing the SSoPGPORT Server The I O Server Infrastructure does not support using SOPGPORT Server as a Windows Service and remote access to SOPGPORT Server when DDE SuiteLink Client is not located on same computer as SSPGPORT Server To uninstall the SSPGPORT Server start Control Panel select Uninstall a program Add Remove Programs on XP 2003 and select the SSPGPORT Server from the list of available software products Click on Uninstall Add Remove on XP 2003 and proceed as directed by the Uninstall Wizard S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 7 Licensing by using HASP HL key The following should be done to enable the licensing by HASP HL key The HASP Device driver and HASP Files are selected during the SSPGPORT Server installation in Custom Setup dialog that causes correspondingly haspdinst exe and hasp_windows_4442 dll files are copied to SOPGPORT Server folder and Sentinel LDK Run time Environment HASP HL Runtime Package is installed and started enabling the SOSPGPORT Server can detect the HASP HL USB dongle insert the received HASP key into USB port and wait until Installing device driver software message disappears and Device driver software installed successfully message appears
33. e server application provides the data and accepts requests from any other application interested in its data Requesting applications are called clients Some applications such as Wonderware InTouch and Microsoft Excel can simultaneously be both a client and a server FastDDE provides a means of packing many proprietary Wonderware DDE messages into a single Microsoft DDE message This packing improves efficiency and performance by reducing the total number of DDE transactions required between a client and a server Although Wonderware s FastDDE has extended the usefulness of DDE for our industry this extension is being pushed to its performance constraints in distributed environments The SSPGPORT Server Suite Link amp DDE version supports the FastDDE Version 3 an extension to Wonderware s proprietary FastDDE Version 2 This extension supports the transfer of Value Time Quality VTQ information The original DDE and FastDDE Version 2 formats are still supported providing full backward compatibility with older DDE clients FastDDE Version 3 works on Windows 9x systems as well as Windows NT systems NetDDE extends the standard Windows DDE functionality to include communication over local area networks and through serial ports Network extensions are available to allow DDE links between applications running on different computers connected via networks or modems For example NetDDE supports DDE between applications running on IBM S5PGPORT
34. erface OPC OLE for Process Control is an open interface standard to provide data from a data source and communicate the data to any client application in a common standard way The OPC is based on Microsoft OLE COM and DCOM technologies and enables simple and standardized data interchange between the industrial or office sector and the production sector From general point of view many aspects of OPC are similar to DDE but main difference is in the implementation by using Microsoft s COM Component Object Model technology It enables fast exchange with process automation data and OPC open interface allows access to data from OPC Server in same standard way from OPC client applications supplied by different developers For more information on the basics of OPC please refer to the OPC Specification The OPC Data Access Custom Interface Specification is maintained by OPC Foundation the current specification is 2 04 dated September 2000 The OPC support for SOPGPORT Server OPC amp DDE version is implemented based on FactorySoft OPC Server Development Toolkit and it conforms to OPC Data Access Custom Interface Specification 2 04 The SSPGPORT Server OPC amp DDE version is tested for compliance and is compatible with OPC Foundation OPC Data Access Compliance Test Tool The Suite Link FastDDE Version 3 and DDE support for SoPGPORT Server Suite Link amp DDE version is implemented by Wonderware I O Server Toolkit ver 7 0
35. f SOPGPORT Server currently is not running it will start automatically Create a new group or topic if Wonderware OPCLink application is used If OPC Client supports the validating of items validate the item before adding it Add the item Depending on OPC Client it can be done in several different ways for example Ro O a By entering separately the access path to topic name valid topic name configured in SSPGPORT Topic definition and separately the item name b By entering the full path to item name in the format TopicName ItemName where TopicName is the valid topic name configured in SSPGPORT Topic definition c By browsing the server address space By default the SSPGPORT Server is installed and used as a local OPC Server both OPC Server and OPC Client reside on same computer The SSPGPORT Server can run also as a remote OPC Server in this case OPC Server and OPC Client are located on separate computers Accessing the remote OPC Server is same as for local OPC Server but some DCOM Distributed COM configuration is required before accessing the remote OPC Server The DCOM configuration must be done both on OPC Server and OPC Client computers S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 24 Configuring DCOM To access SSPGPORT Server as a remote OPC Server it is necessary to install S5PGPORT Server on both OPC Server and OPC Client compute
36. for work to do at this frequency the Server tries to send one data request to PLC and receive one reply from PLC If the send response cycle is too long then more than one activation of Server is necessary to process it If computer is very busy or some other MS Windows application is taking over the computer then the Server is activated rarely than setting in S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 13 the Protocol Timer Tick Note The default value is 50 milliseconds The minimum value is 10 milliseconds NetDDE being used Select this option if you are networking using NetDDE Configuration File Directory This field is used to specify the path disk drive and directory in which SSPGPORT will save its current configuration file The SSPGPORT Server will use this path to load the configuration file the next time it is started Note Only the path may be modified with this field The configuration file is always named SSPGPORT CFG Note There is no limit to the number of configuration files created although each must be in a separate directory When using the SOPGPORT Server with InTouch it is good practice to place the configuration file in the application directory Start automatically as Windows NT Service Enabling this option will cause the SSPGPORT Server Suite Link amp DDE version to start as a Windows NT service Windows NT offers the
37. h write to this topic PLC If ShowAllRejectedWrites 1 then information about each rejected write value is reported to WWLogger and or to SSPGPORT Internal Logger If ShowAllRejectedWrites 0 default then Server rejects each write to suspended topic s without logging any information Troubleshooting menu The following debugging choices are appended to the Server s System Menu the menu that appears when you click the Server icon in the upper left hand corner of the Server window Suspend Protocol Resume Protocol these choices permit you to turn protocol processing on and off what allows you to suspend access to PLC s Show Send if checked then all outgoing data is displayed in hexadecimal format Show Receive if checked then all incoming data is displayed in hexadecimal format Show Errors if checked then all information about errors is displayed ShowRejectedWrites if checked then information about rejected write messages is logged Show Logger if checked then SSPGPORT Internal Logger is activated and all debug information is going to SSPGPORT Internal Logger The S5PGPORT Internal Logger file is named in the format S5PGPORT_YYYYMMDD LOGn where YYYY is a year MM is a month DD is a day and n is a order number of consecutive SSPGPORT Internal Logger file starting from 1 the SSPGPORT Internal Logger file maximimum size is 16 MB if there is more information logged then next consecutive file is S5PGPORT Communica
38. ing type letter must give a fully qualified OPC item name for the S5SPGPORT Server Some examples of possible item names acceptable by OPCLink Server SSPGPORT Server connection S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 28 dDB10D20 15 discrete data block 10 bit 15 of data word 20 iFB100 integer flag byte 100 value in the PLC is binary and has a range of 0 to 255 mDB10DS20 8 message data block 10 value in the PLC is character string containing 8 bytes and starting at data word 20 Using the SSPGPORT Server with Suite Link and DDE Clients The Suite Link amp DDE version of SOPGPORT Server is accessible from Suite Link clients e g InTouch and DDE clients e g Excel The OPC amp DDE version of S5PGPORT Server is accessible from DDE clients Using the SSPGPORT Server with InTouch To access to items points on the Simatic S5 PLCs from InTouch the Access Names and Tag names should be defined in WindowMaker Defining the Access Names InTouch uses Access Names to reference real time I O data Each Access Name equates to an I O address which can contain a Node Application and Topic Ina distributed application I O references can be set up as global addresses to a network I O Server or local addresses to a local I O Server To define the Access Names in WindowMaker node invoke the Special Access Names command The Access Na
39. ition dialog box will appear S5PGPORT Topic Definition Topic Name 595 1 i re Com Pott com x Cancel Update Interval 1000 msec Enter the Topic Name Note If using InTouch the same Topic Name is to be entered in the Add Access Name dialog box described in the Using the SS5SPGPORT Server with InTouch section Click on the Com Port button to associate a topic with the communication port Note Additional topics may be associated with the same communication port later Set the Update Interval field to indicate the frequency the items points on this topic will be read polled Default value is 1000 milliseconds When all entries have been made click on OK to process the configuration for this topic S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 17 Running the SSPGPORT Server Startup sequence The SSPGPORT Server uses AS511 programming port protocol to communicate with Simatic S5 PLCs All PLC data areas are accessed by absolute addresses The Server reads start addresses of Flags Inputs Outputs Counters Timers Data Blocks and Extended Data Blocks For Data Blocks and Extended Data Blocks the Server also reads the block size These values are used to validate the item names and to create read and write commands to be sent to PLC These absolute addresses are determined when Server opens the serial port i e when first topic associate
40. mes dialog box will appear S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 29 Access Names Close Modi as Delete Click on Add The Add Access Name Dialog Box will appear Add Access Name Access Name 5951 r 7 Node Name Cancel NODE Application Name S5PGPORT Topic Name 5951 Which protocol to use C DDE SuiteLink When to advise server C Advise all items Advise only active items Note If Add is selected this dialog box will be blank when it initially appears Data has been entered here to illustrate the entries that are made The following fields are required entries when entering an Access Name Definition Access Name In the Access Name box type the name you want InTouch to use to this Access Name For simplicity use the same name that you will use for the Topic Name here Node Name If the data resides in a network I O Server in the Node Name box type the remote node s name Application Name In the Application Name box type the actual program name for the I O Server program from which the data values will be acquired In case the values are coming from the S5PGPORT Server the SSPGPORT is used Do not enter the exe extension portion of the program name S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Ser
41. names described in the Item Names section Reading Values into Excel Spreadsheets Values can be read directly into Excel spreadsheets by entering a DDE formatted formula into a cell as shown in the following examples S5PGPORT S95_1 QB0 S5PGPORT 135_3 IW10 S5PGPORT S95 _2 DBODW1 The status item can be read by entering the following formula in a cell S5PGPORT topic STATUS Note Refer to the Microsoft Excel manual for complete details on entering Remote Reference formulas for cells S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 34 Writing Values to SSPGPORT Points Values may be written to the Server from Microsoft Excel by creating an Excel macro that uses the POKE command The proper command is entered in Excel as follows channel INITIATE SSPGPORT topicname POKE channel itemname Data_Reference TERMINATE channel RETURN The following describes each of the above POKE macro statements channel INITIATE SSPGPORT topicname Opens a channel to a specific topic name defined in the Server in an application with name S5PGPORT the executable name less the EXE and assigns the number of that opened channel to channel Note By using the channel INITIATE statement the word channel must be used in the POKE statement instead of the actual cell reference The applicationname and topicname portions of the formula must be enclosed
42. nication Server 11 Connection Cables To connect Simatic S5 PLC to your computer you can either use some manufactured cable or you can make your own connections via a converter between the RS 232 serial port on the computer and the 20 mA current loop on the PLC The programming ports on various Simatic S5 PLCs are not identical and therefore care must be taken to establish the proper communication The SSPGPORT Server is tested with the ENTRELEC model ILPH RS232 CL Current Loop Serial Link Interface The following wiring diagram requires active PLC programming port can be used to connect computer s RS 232 serial port and PLC e g Simatic S5 95U or S5 135U programming port PC ENTRELEC 5 95U or S5 135U 9 pin female clamp clamp 15 pin male 3 SD M RXD E RXD 2 RD L TXD F RXD 5 SG K OV B TXD C TXD DIP Switches 1 ON TXD ACT 2 ON RXD ACT 3 OFF 0 20 mA 4 ON 1 20mA The following wiring diagram can be used to connect computer s RS 232 serial port and Sinumerik PLC programming port Computer Sinumerik PLC i 3 TxD TxD 2 7 RTS x RTS 4 8 CTS CTS 5 TOO O O a n 6 DSR DSR 6 5 GND GND 7 S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 12 Configuring the SSPGPORT Server After the SSPGPORT Server is initially installed a small amount of configuration is required Configuring the Server automatically creates a SSPGPORT CFG file
43. not be used as a remote OPC Server then custom access and launch permissions NETWORK are not needed To uninstall SSPGPORT OPC amp DDE Server NT Service at first the Service must be stopped by Control Panel Services Stop and then SSPGPORT Server must be started manually with command line parameter DelService S5PGPORT DelService After this the SSPGPORT Server OPC amp DDE version will be still registered and accessible to OPC clients Using SSPGPORT with OPCLink Server The Wonderware OPCLink I O Server hereafter referred to as OPCLink is a Microsoft Windows application program that acts as a communication protocol converter and allows other Windows application programs access to data from local or remote OPC servers OPCLink connects to OPC servers converts client commands to OPC protocol and transfers data back to clients using DDE FastDDE or Suite Link protocols Please refer to Wonderware OPCLink Server and OPC Browser User s Guide for details how to install start and use the OPCLink Server The following information in this section covers only the most important points about using OPC amp DDE version of S5PGPORT Server with OPCLink Server OPCLink Topic Definition The Topic Definition option from OPC Link Configure menu is used to create modify or delete OPCLink topic definitions If OPC Link will communicate with SOPGPORT Server then there must exist one or more topics defined for SSPG
44. nse now is enabled Note the Software Key string is saved to MS Windows system directory e g C Windows WIN INI file SSPGPORT Server section to enable it is automatically detected at SOPGPORT Server next start up Transferring the software license to other computer The transfer of Software License Key might be needed in very rare situations when it is necessary to move Klinkmann software to other computer or operation system change is planned for same computer Such transfer PERMANENTLY removes the Software License Key so be very careful when deciding to use this option The following steps are required to transfer the Software License Key 1 Start the SOPGPORT Server For SSPGPORT Server Suite Link amp DDE version the ArchestrA SMC Log Viewer or Wonderware Logger must be started For S5PGPORT Server OPC amp DDE version the SSPGPORT Internal Logger and Log to File should be enabled see Troubleshooting menu and Internal Logger sections at the end of this manual Select Help License from main menu and click the Transfer button on License dialog x Product Code DRI 6010149 Customer PC Code d14a b075 4921 dabe Transfer Software Key bat3 1 16fd c5d 0626 Cancel 2 Confirm the transfer of Software License Key by clicking on Yes button S5PGPORT xj Do you really want to transfer Software Key to other computer and permanently remove Software Key from this
45. ppear Access Names Unassigned Add Ho Delete Select the appropriate Access Name and click on Close If the Access Name has not been defined as previously described click on Add and define the Access Name now The Details dialog box will appear displaying the selected Access Name S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 32 Initial Value fo Min EU fo Max EU 3999 Deadband jo Min Raw J0 Max Raw 3999 a O Conversion Eng Units gos i H 5951 2 Square Root ltem M Use Tagname as ltem Name Log Deadband jo For integer data fill in the Min EU Max EU Min Raw and Max Raw fields These fields control the range of values which will be accepted from the Server and how the values are scaled If no scaling is desired Min EU should be equal to Min Raw and Max EU equal to Max Raw Enter the SSPGPORT item name to be associated with this tagname in the Item field in the Details box Initial Value fo Min EU jo Max EU 3999 Deadband jo Min Raw f0 Max Raw 9999 Conversion Eng Units ima H 5951 C Square Root ltem QB32 Use Tagname as ltem Name Log Deadband jo Refer to the Item Names section below for complete details Where applicable the Use Tagname as Item Name option may be selected to automatically enter the tag name in this field Note The tag name can only be used if it follo
46. rs Also the DCOM must be configured on both computers After Server installation the System Administrator must configure DCOM by Dcomcnfg exe or Dcomcnfg32 exe for Win9x system tool This utility is located in the Windows system directory e g in WinNT system32 or Win9x system Below is a simple example how to configure DCOM on NT Workstations for OPC Server computer computer name JohnB and on OPC Client computer computer name SteveL Remote OPC Server OPC Client Computer name Computer name JohnB v Invoke Default Properties and set Default Authentication Level to None Default Impersonation Level to Impersonate mes Select OPC Server from Applications list and click on the Properties button Click on the Location tab uncheck Run application on this computer check Run application on the following computer and browse the remote computer JohnB Edit Security settings 1 set the following custom access permissions NETWORK SYSTEM SteveL 2 set the following custom launch permissions INTERACTIVE SYSTEM NETWORK SteveL 3 be sure the Default Configuration Permissions contain SYSTEM Click on the Identity tab and select The v interactive user Before starting a remote OPC Server be sure the OPC Server computer and OPC Client computer can access each other on the network The Remote Procedure Call Service should be started on OPC Server computer S5PGPORT Communication Server
47. rver will run one hour in demo mode After purchasing the S5PGPORT Server the appropriate HASP key or software license key is provided and no re installation of SSPGPORT Server is needed In case HASP Device driver and HASP Files are not selected then HASP USB key will not be supported and only the software license will be available files needed for HASP USB key will not be installed i S5PgPort Suitelink Server Setup o x custom setup Select the way you want features to be installed Click the icons in the tree below to change the way features will be installed XX Seekers X HASP Files Sentinel LDK Run time Environment HASP HL Runtime Package This feature requires OKB on your hard drive S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 5 In case HASP Device driver and HASP Files are selected then HASP USB key will be supported and both HASP key and software license will be available files needed for HASP USB key will be installed ie S5PgPort Suitelink Server Setup Hs 5 x custom setup Select the way you want features to be installed Click the icons in the tree below to change the way features will be installed HASP Device driver Sentinel LDK Run time Environment HASP Files HASP HL Runtime Package This feature requires 15MB on your hard
48. s To communicate with certain CPUs the SSPGPORT Server has to know the type of CPU The following selections are available Simatic S5 135U with CPU 922 928 928B Simatic S5 115U with CPU 945 or Simatic S5 155U with CPU 946 or CPU 947 Sinumerik PLC with CPU 840C All remaining Simatic S5 PLCs with CPUs not listed above this is default setting Note For Sinumeric PLC s it is possible to access only to Data Blocks and Extended Data Blocks The following other communication parameters are used Baud Rate 9600 8 Data Bits 1 Stop Bit Even Parity These parameters can not be changed When all entries have been made click on Done to process the configuration for the communication port S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 15 Saving SSPGPORT Configuration File If the configuration file does not currently exist or a new configuration path has been specified the Server will display the Save Configuration dialog box Save Configuration Configuration File Directory C SSPGPORT Defaults IV Make this the default configuration file This dialog box displays the path where the Server is going to save the current configuration file The path may be changed if necessary Also the path can optionally be recorded in the WIN INI file by selecting the Make this the default configuration file option Doing so it will allow the
49. se OPC items window in alphabetical order Note For Data Blocks and Extended Data Blocks the available address space will be exposed only after the Startup sequence see Running the SSPGPORT Server section successful execution Accesing SSPGPORT Items via the OPCLink Server The communication protocol addresses an element of data in a conversation that uses a three part naming convention that includes the application name topic name and item name The following briefly describes each portion of this naming convention application name The name of the Windows program server that will be accessing the data element In the case of data coming from or going to SSPGPORT Server OPC amp DDE version the application portion of the address is OPCLINK topic name Meaningful names are configured to identify specific devices PLCs These names are then used as the topic name in all conversations to that device PLC This must be same name as Topic Name entered in the OPCLink Topic Definition dialog box for example PLC1 Note You can define multiple topic names for the same PLC to poll different points at different rates item name A specific data element within the specified topic The OPCLink Server item syntax follows the following rules The item names must start with d discrete value i integer value r real value m message value The item name added to the OPC path of the topic without the head
50. se file In case the HASP Device driver is selected during the installation in Custom Setup dialog the Sentinel LDK Run time Environment HASP HL Runtime Package is installed during the SSPGPORT Server installation and will be uninstalled during the SSPGPORT Server uninstallation The presence of Sentinel LDK Run time Environment can be checked after the SSPGPORT Server installation by looking up in Control Panel Administrative Tools Services the Service Sentinel Local License Manager must be started Notes 1 The SSPGPORT Server Suite Link amp DDE version is developed with Wonderware I O Server Toolkit ver 7 2 1 6 and needs the Wonderware FS 2000 Common Components to be installed on computer where the SoPGPORT Server is running If using Wonderware InTouch 8 0 or newer install the FS 2000 Common Components before installing InTouch see also Wonderware Tech Notes 404 and 313 The Wonderware FS2000 Common Components are installed automatically when any of Wonderware product e g InTouch or some Wonderware I O server is installed 2 If SOoPGPORT Server Suite Link amp DDE version will run on PC where Wonderware FS2000 Common Components are not installed then a special I O Server Infrastructure installation package can be obtained from Klinkmann Automation see Installing the VO Server Infrastructure section below This I O Server Infrastructure installation package contains the minimum set of softwar
51. that holds all of the topic definitions entered as well as the communication port configurations This file will automatically be placed in the same directory in which SSPGPORT EXE is located unless the path where the configuration file will be placed is specified via the Contigure Server Settings command To perform the required configurations start the SSPGPORT program If the Server starts up as an icon then double click on the icon to open the server s window To access the commands used for various configurations open the Configure menu 2 SSPGPORT OF x Contigure Help Com Port Settings Topic Definition Server Settings Server Settings Command A number of parameters that control the internal operation of the Server can be set In most cases the default settings for these parameters provide a good performance and do not require changing However they can be changed to fine tune the Server for a specific environment To change the Server s internal parameters invoke the Configure Server Settings command The SSPGPORT Server Settings dialog box will appear S5PGPORT Server Settings Protocol Timer Tick 50 msec f I NetDDE being used Cancel Configuration File Directory CAS5PGPORTS I Start automatically as Windows NT Service The following describes each field in this dialog box Protocol Timer Tick This field is used to change the frequency at which the Server checks
52. tion Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSPGPORT Communication Server 37 created e g there can be consecutive files S5PGPORT_19990413 L0G1 SSPGPORT_19990413 LOG2 etc Dump displays all information about opened ports active topics and data items All debug information is displayed via the Wonderware Logger or and to SOSPGPORT Internal Logger if Show Logger is checked which must be active for these commands to work Warning if you check Show Send and or Show Receive then debug output grows very fast Internal Logger To enable the SSPGPORT Internal Logger check the Show Logger option at the S5PGPORT Server System Menu see Troubleshooting menu section above this command can be used to start stop the Internal Logger The Internal Logger window looks like following ioj xi Options 2013 02 28 14 29 00 966 SSPGPORT Configuration file is CAPROGRAM FILES x86 KLINKMANN AlL a 2013 02 28 14 29 13 563 SSPGPORT Walid software key entered 2013 02 28 14 29 16 506 SSPGPORT Closing 2013 02 28 14 29 19 083 SSPGPORT Startup 1 49 OPC amp DDE 2013 02 26 14 29 19 083 SSPGPORT Wonderware Common Dialog Version 3 19 2013 02 28 14 29 19 088 SSPGPORT Valid software license found 2013 02 28 14 29 19 088 SSPGPORT Configuration file is C PROGRAM FILES lt 86 KLINKMANN AL 14 To save Internal Logger information to file select Options Disk Options from Internal Logger main menu
53. ver 30 Topic Name Enter the name defined for the topic in the SOSPGPORT Server to identify the topic the S5PGPORT Server will be accessing The Topic Name is an application specific sub group of data elements In the case of data coming from a SSPGPORT Server program the topic name is the exact same name configured for the topic in the SSPGPORT Server Note This will usually be the same as the Access Name although if desired they may be different However it must be the same name used when the topics were configured in section Configuring the SSPGPORT Server Which protocol to use Select the protocol DDE or Suite Link that you are using When to advise server Select Advise all items if you want the Server program to poll for all data whether or not it is in visible windows alarmed logged trended or used in a script Selecting this option will impact performance therefore its use is not recommended Select Advise only active items if you want the Server program to poll only points in visible windows and points that are alarmed logged trended or used in any script Click OK to accept the new Access Name and close the Add Access Name dialog box The Access Names dialog box will reappear displaying the new Access Name selected in the list Click Close to close the Access Names dialog box Defining the Tag names To define the Tag names associated with the new Access Name invoke the Special Tagname Di
54. ws the conventions listed in the Item Names section Once all entries have been made click on the Save button in the top dialog box to accept the new tagname To define additional tagnames click on the New button To return to the WindowMaker main screen select Close S5PGPORT Communication Server Ver 1 x User Manual Rev 1 12 160XXM112 Klinkmann Automation SSsPGPORT Communication Server 33 Monitoring the Status of Communication with InTouch InTouch supports built in topic names called DDEStatus and lOStatus which are used to monitor the status of communication between the Server and InTouch For more information on the built in topic names DDEStatus and lOStatus see your online InTouch User s Guide The status of communication between the Server and InTouch can be read into Excel by entering the following DDE reference formula in a cell on a spreadsheet in following examples 95_1 is the Topic Name configured for SOPGPORT Server view DDEStatus S95 1 or view lOStatus S95 1 Notes on Using Microsoft Excel Data from SSPGPORT topics PLCs may be accessed from Excel spreadsheets To do so enter a formula like the following into a cell on the spreadsheet S5PGPORT topic item Sometimes Excel requires the topic and or item to be surrounded by apostrophes In the formula topic must be replaced with one of the valid topic names defined during the Server configuration process Replace item with one of the valid item