OM NOMAD RH T Nomad Datalogger QuickStart Manual

image

Contents

1. Warranty Disclaimer NEWPORT ELECTRONICS INC warrants this unit to be free of defects in materials and workmanship for a period of one 1 year from date of purchase In addition to NEWPORT s standard warranty period NEWPORT ELECTRONICS will extend the warranty period for one 1 additional year if the warranty card enclosed with each instrument is returned to NEWPORT If the unit should malfunction it must be returned to the factory for evaluation NEWPORT s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by NEWPORT if the unit is found to be defective it will be repaired or replaced at no charge NEWPORT s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of NEWPORT s control Components which wear are not warranted including but not limited to contact points fuses and triacs NEWPORT is pleased to offer suggestions on the use of its various products However NEWPORT neither assumes responsibility for any omis
2. clock setting Dont stop menarin ody Temperature alarm user specified limits in degree ForC Excursions beyond soa a set limits are displayed ae on Plot Pressing Run button while recording will indicate alarm excursions on the NOMAD LED Relative Humidity alarm 20 to 90 allowed On line help available NOMAD Datalogger Launch and Offloading with DOS Readout Configure amp Launch Cancel Setups Com Port Print amp Export format Cancel Help Help on help Getting started Manual About logger Cancel NOMAD DATALOGGER User may navigate through menus using the mouse or the keyboard accelerators Accelerator keys are shown with highlighted letter Windows will have mark button for access to context sensitive information Readout and Plotting Windows and Macintosh From NOMAD Datalogger menu select Setup sub menu Readout Eiei View Heip After data download the attached NOMAD information will appear Alternately from File select Open to view a previously saved data file One file at a time The Y axis automatically scaled for maximum resolution based upon max and min data records Temperature shown on left in segmented red while RH is shown on the right in continuous blue line Recording start date and time stamp along the X axis with serial number and units of sampling interval selected Export Setup Export Format Select popular pre defined data formats
3. J9 34 PPE IIM LYOdMGN S NA yoeoiddy man uesdoing au 0 sjonpoud s Jo uoge Buinsund Ajue suod s LYOdMAN Aidde yey suopejn6a1 W3 OWS pue Ajeyes PIMPHOM Jle ym jdwo 0 1LYOdMAN 40 Aatjod y S 4 80HO LYOdMIN 290 JNOA je9 10 n LYOdMAN 008 G6 091X WN U LYOdMIN 008 epeued pue Y S N 34 Ul vugys ssy pow 104 woo snyodmeu ojur woo snvodmeu mmm pew a yausazuy 9919S BUIT UO J2ULHOdMAN 082 6S 0Z 100 louedsy ug 2082 6S 0Z L00 XW Zv 9 9Z8 008 100 TAL Bovey ule pue OdIxe 4ypodmeu sejes ew yyodmeu mmmy dyy ZyE90 P 0080 9914 IOL OZL 669 OEL XV4 OOF LZ9 OEL E TAL eouel4 saddeil 06482 uldeg siueg ens G TXY S nbjuo123 3 POdM N p podm u s es ew 9 P HPOdM UMMW dYY 8 9 6 9 0080 3914 IOL 6Z 86 6 9902 6f XV4 0 86 6 9902 6p TAL Auewsag uuoydueyx99q Z6ES C 9Z sseyssajwreq Hqw9 sojuo j99 9 POdM N zoyodm u s Jes ew ZI POdM U MMM dYY ZYE99 L 0080 9914 IOL YLLLLE9 69 OZb XV 668LLE9 69 OZp TAL oyqndey y9 Z9 8 PULY LO EEZ 898 ppuue Pny ous jods 91u01 99 3 HOdM N u podmou seajes pew ju odmeu mmwmy dyy PYEEEEO 0080 3914 IOL EvOvVEPO OZ LE XWA LZLZZVE OZ LE TAL SPUCLOYJON OU UBOA 9ISWUY VT 08LL HE08 SNQSOd N9 S9 u01 99 J HOdM N ynov ynpodmau sajes pew YNO YNYOdM U MMM dYY 887 887 0080 3914 IOL ZZ99 LLL LOL vet XWA LL
4. for Microsoft Excel applications Lotus 1 2 3 ae al Readable Text summary from the View menu for detailed information about the export format Custom allows user to specify time format and field separators Accept chosen parameters NOMAD application description User entered at time of launch Zoom in on any selected plot Using the mouse click and drag draw box around area of interest Multiple zooms are allowed Plots can be copied and imported into applications running under Windows or MAC Select information to export temperature and humidity counts are used primarily as diagnostic tool Export Options information Exported Ed Sample Number EJ Time amp Date E Temperature Temperature F 2 Temperature in Counts Humidity E Humidity in Counts On line help available Abort selection process
5. set to correct time since NOMAD obtains its time stamp from your computer To start NOMAD for Windows inside Windows click on the NOMAD Icon To start NOMAD in DOS type CD NOMADOS and press return Then type NOMAD and press return NOTE Please review the on line user manual for a complete description of all features This is a text file included on the installation disk File Name manual txt This device is marked with the international hazard symbol It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safety and EMC Ordering Information MODEL DESCRIPTION OM NOMAD T 16 N Temperature datalogger 16K memory 16 192 samples OM NOMAD RH 32 N Temp RH datalogger 32K memory 16 192 samples OM NOMAD RTD External temp sensor with 6ft cable NOTE Not useable with OM NOMAD RH models OM NOMAD CP9 RS 232 cable for IBM PC 9 pin female D sub connector OM NOMAD CP25 RS 232 cable for IBM PC 25 pin female D sub connector OM NOMAD CM RS 232 cable for Macintosh OM NOMAD WIN N Windows DOS software 3 5 disk OM NOMAD MAC N Macintosh software OM NOMAD BATT Replacement battery To place an order from the USA or Canada call 1 800 NEWPORT Slide to Open Battery Compartment bs Dimensions Length 2 80 71 1mm Width 2 20 55 9mm Depth 0 96 24 4mm Launching the NOMAD DATALOGGER Att
6. 99 ZZZ LOL bes OL wopBury parun Gas YY Je seyoueyy WEL YUeqULON aqueg ABojouyse pu g Ajy eaw euO pr soluos 99 9 HOdM N eo Lodmau seyjes lew a eo odmeumMmy dyy 8 9 6E9 008 82 4 IOL 9889 958 PLS XVY4 8LE GEE YLS TAL epeuep LYS 74H 98q nD jere e6109 9 6 ou seiBojouyse POdM N payed 1006 OSI Woo SnLodmeu ojur jew s woo snyodmeu mmwy dyy 829 6E9 008 1 82 4 IOL ZZ0 90S PLZ XY4 PLEP OPS LZ TAL VSN POLZE WO BUY e URg 439S AJLA YNOS BzZZ oul S91u0 99 J POdM N S287028 888 L e9 se jd eoueysisse uopevjdde Jo jeoJUYyda Je pawwu 104 NOMAD Quick Start Install NOMAD software DOS version insert diskette in floppy drive At the DOS prompt type A INSTALL and press enter If floppy drive is B then at DOS prompt type B INSTALL followed by enter Windows version Before installation all programs must be closed and ensure that terminant resident TSR programs are turned off These programs have been found at times to conflict with the installation process Insert diskette into floppy drive from file manager choose File Run Type A SETUP and press enter Use B SETUP if floppy is the B drive Macintosh version insert diskette into floppy drive drag the NOMAD Datalogger folder onto your hard drive To start NOMAD open the Nomad Datalogger Folder and doubleclick on the NOMAD icon Verify your computer clock is
7. ach the NOMAD to an available Serial port of your computer using your RS 232 cable purchased with your unit see ordering block If you wish to use the external sensor with Temp dataloggers only plug it in to the Temp Probe socket on the NOMAD From program manager select Nomad icon Cancel about the datalogger screen by keyboard return or select OK button The NOMAD Datalogger screen will appear Select logger sub menu configure and launch datalogger NOTE If NOMAD is not connected an error message Port is available but no NOMAD was detected will be displayed Check hardware connections and select COMPORT under the Setup menu for alternate ports to test Once successful you will be greeted by the Launch datalogger screen Follow your application requirements in choosing the appropriate menu item using on line help as needed NOMAD Logger Specifications Temperature Operating range with internal sensor 10 to 70 C 14 to 158 F Measurement range with external sensor 40 to 123 C 40 to 253 F Accuracy 1 8 C using internal sensor Electronics temperature coefficient of error using external sensor 025 Full Scale C Resolution better than 0 9 C Sensor 1 K ohm RTD alpha 3750 Humidity Measurement range 20 to 90 non condensing Operating temperature range 0 50 C Measurement accuracy 5 RH 25 C 0 3 RH C away from 25 C Sensor Bu
8. lk polymer resistive RH response 63 of step change in less than 5 minutes Measurement Interval Programmable from 1 second to 3 hours EEPROM memory size 16K data samples Battery one 3 6 volt AA Lithium Cell operating for more than 2 years Launching the NOMAD DATALOGGER MAC DOS amp Windows 3 1 and above Recording starts immediately upon Launch command Recording starts at time set in entry box Recording starts after Run button is pressed on Datalogger Recording starts following a user specified delay time set in the entry box after Run button is pressed Sampling option selects single recording or the highest lowest or average of 4 samples Sampling interval in seconds minutes or hours may be specified Automatically calculated from interval entry and device capacity Recording capacity of NOMAD model dependent User entry Describe the NOMAD application will appear on print plot Lamh the Datogqger Wyott manor is full AL ime spocified br ps X When bution on datwogger ls pressed Arter delay starting when button k pressed a _ System Time 8 23 1997 14 05 35 Teta Pasar Langt div Ann Daiji Cangas hy thie Start sampling Abort Launch Piel A Warak Sovtal Stop sampling when memory is full Continuous recording most recent data available NOMAD Serial Factory Assigned Current time stamp based on host computer s internal
9. rademarks of NEWPORT Electronics Inc NOMAD is a trademark of OMEGA Engineering Inc Used under license right 2001 NEWPORT Electronics Inc All rights reserved This document may not be copied photocopied reproduced _or reduced to any electronic medium or machine readable form in whole or in part without prior written consent of NEWPORT Electronics Inc M2510 N 0701 Ayayyeq yim seouno z juo SUBIS e swes6oJd 194 0 Ul asn JO eyep odxe pue sjud ayew szojd MAIA 0 BIEMYOS VOJNO Alpualy Jasn SOA SMOPUIM e siebboyeyep OINJEIBGWU9 104 JOSUBS GLY 2U19 X4 ajqiyedwoo ysojuldey JO Ode Hulpsoo9es punose des JO a 6uls suueje ajqewwesbold Bulpjooed LUNWIXeWW JO LUNWIUILU 35e s pow YOUNL JUSIOJIP pe Auayyeq ajqesoejdas uo uonesedo sieak Z 19310 Buideey p10991 JO oww WOHd33 3 0AUON sieak Z JOAO 0 UILU 6Z SIU y WO YIHUd p1029 H e SpJOO9l Z61 Ole sainjeo4 Jabbojeyeg GVINON NOMAD CE Datalogger OM NOMAD T OM NOMAD RH Operator s Manual MADE IN THE U S A Vv NEWPORT Electronics Inc suo jeol dde payoeuuos zu ped 104 pasn aq jou pjnoys pue ul asn 104 pauBisap jou ase sjonpoid SL NINYYM aopou JnoUyIM SUOHeoyIOads Jaye 0 yu y S M S J pue SUIeJUOD S10 Aue 104 Ayigel ou sydaooe uy S91U0s 99 9 1YOdMAN INq P2109 aq 0 paAaljaq S JU WNIOP SIY U PauleyUOD UOWEWJOJU yL uoneoyiiea uodn aolaap ayeudoidde Ajana 0 yew
10. s from any liability or damage whatsoever arising out of the use of the Product s in such a manner Return Requests Inquiries Direct all warranty and repair requests inquiries to the NEWPORT Customer Service Department BEFORE RETURNING ANY PRODUCT S TO NEWPORT PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM NEWPORT S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the FOR NON WARRANTY REPAIRS consult following information available BEFORE contacting NEWPORT for current repair charges Have the NEWPORT following information available BEFORE contacting 1 P O number under which the product was NEWPORT PURCHASED 1 P O number to cover the COST of the repair 2 Model and serial number of the product under warranty and 3 Repair instructions and or specific 2 Model and serial number of product and 3 Repair instructions and or specific problems relative to the product problems relative to the product NEWPORT s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering TRADEMARK NOTICE N U NEWPORT NEWPORT CO MANY and INFINITY are t
11. sions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by NEWPORT either verbal or written NEWPORT warrants only that the parts manufactured by it will be as specified and free of defects NEWPORT MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of NEWPORT with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall NEWPORT be liable for consequential incidental or special damages CONDITIONS Equipment sold by NEWPORT is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way NEWPORT assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify NEWPORT and hold NEWPORT harmles