1. InstallShield Fig 1 4 Press Install Labtool S100 Software InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation Click Install to begin the installation IF you want to review or change any of your installation settings click Back Click Cancel to exit the wizard InstallShield 45 Fig 1 5 Installing Labtool S100 Software InstallShield Wizard Setup Status InstalShield Fig 1 6 Press Finish Labtool S100 Software InstallShield Wizard InstallShield Wizard Complete The InstallShield Wizard has successfully installed Labtool S100 Software Click Finish to exit the wizard 46 Step2 Turn the LABTOOL S100 power on You will see the messages Fig 2 1 Select No not this time and then press Next Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for software O Yes this time only O Yes now and every time connect a device ON Click Next to continue Ce Fig 2 2 Select Install the software automatically Recommended and then press Next Found New Hardware Wizard This wizard helps you install software for Serial Pr
2. Box header definition PIN 1 Typical 8 pin or 16 pin SPI flash signal definition Pin SPI flash SPI flash Number Signal Function 1 2 CS Chip Select 3 SO Serial Data Output 4 WP Write Protect 5 GND Ground 6 SI Serial Data Input 7 SCK Serial Clock 8 RST HOLD Reset or Hold 9 VCC Power Supply 10 Macronix MX25L25835E 16 pin SPI flash signal definition Pin SPI flash SPI flash Number Signal Function 1 CS 2 Chip Select 2 2 CS 1 Chip Select 1 3 SO Serial Data Output 4 WP Write Protect 5 GND Ground 6 SI Serial Data Input 7 SCK Serial Clock 8 HOLD Hold 9 VCC Power Supply 10 RST Reset 13 Device support summary The latest software the software download and update from www aec com tw Flash memory SPI EEPROM and other flash technology Specification Socket and pin driver 4 fully isolated adapter module with receptacle over 10 M ohm resistance between each adapter module One DAC for Vcc with 8 bit resolution range OV 4V and maximum 100mA Over current protection with ploy switch and maximum 200mA Logic level 3 3 V to 1 8 V programmable by software Device Operation Read blank check insertion contact check verify check sum erase chip program memory protect edit buffer configuration load file save file project file load save File format Binary Intel HEX Intel extend HEX Motorola S HP64000ABS TEK HEX
3. 5 Hz frequency This mode only applies to insertion and contact checks of the chips in the socket Flashing Green the chip passed the continuity check Flashing Yellow the adapter module is active and waiting for a chip to be inserted Flashing Red the chip failed the insertion continuity check due to poor contact incorrect chip positioning pin count mismatch chip upside down pin short circuit or chip damage 21 File Commands Save Buffer Menu File Save Buffer Hot key Alt S This option is used to save the memory buffer to a file on the hard disk Select a file to overwrite using the mouse or type the file name in the box provided You can also type in a file spec e g hex bin atthe Name prompt This will display all the files of the specified type and you can then select the required file to overwrite File Format Select the file format of the output file Buffer Mode This mode functions as follows Normal Every byte is written to the output file Even 1 of 2 Every Even byte is written to the output file Odd 2 of 2 Every Odd byte is written to the output file lst byte of 4 This writes the bytes 1 5 9 13 into the output file 2nd byte of 4 This writes the bytes 2 6 10 14 into the output file 3rd byte of 4 This writes the bytes 3 7 11 15 into the output file 4th byte of 4 This writes the bytes 4 8 12 16 into the output file From Buffer Address A sele
4. Adapter ADP QFN 0801 ADP QFN 0802 ADP QFN 0803 ADP QFN 0804 ADP SOIC 1601 ADP SOIC 2001 ADP SOIC 2801 ADP TSSOP 1601 ADP EBGA 2401 ADP EBGA 2402 Description LT S100 Adapter for 8QFN Pitch 1 27mm Package 5 6mm LT S100 Adapter for 8QFN Pitch 1 27mm Package 6 8mm LT S100 Adapter for 8QFN Pitch 0 5mm Package 2 3mm LT S100 Adapter for 8QFN Pitch 0 8mm Package 4 4mm LT S100 Adapter for 8SOIC 150mil LT S100 Adapter for 8SOIC 200mil LT S100 Adapter for 16SOIC 300mil LT S100 Adapter for 8pin TSSOP SPI chip LT S100 Adapter for 24 ipin EBGA M 4x6 P 6x8mm LT S100 Adapter for 24 tpin EBGA M 5x5 P 6x8mm 38 APPENDIX A Error Messages 39 Error Messages This function is not supported in demo mode When the LABTOOL S100 is not activated some functions may be inhibited Illegal range of erase address setting Retry again The address range for an erase command must match the sector edge Time Out error The LABTOOL S100 does not respond when the system times out Cannot open file XXXXXXXX The file was not found or a disk error occurred Device ID Code unmatched The current chip s ID will be displayed File write error Illegal file name or disk error The LABTOOL S100 detected an error when writing a file to disk Check that there is enough space on the disk to hold the file Also check that the disk is not write protected This might happen on a network if you are a user that does not have
5. Documents and Settings My Documents Advantech Equipment Corp LabTool S100 folder there is a serial number text file of the LABTOOL S100 e g AE1202000001 rep after the self test function The file includes system information and hardware tested result If you need to update or upgrade or repair the LABTOOL S100 please send the report file e g AE1202000001 rep to us We will do our best service for you LabTool S100 gt AE1201000006 LabTool S100 Serial Flash Programmer File i Device Option nosti o Save Load Select Auto Found LabTool 5100 AE1201000006 Report file path C Documents and Settings yuhding chang My Documents Advantech Equi gt gt Report file AE1201000006 rep Self Test System General Pass RAM Pass BOOT Pass Driver Pin Pass Exit Device cFeon EN25540 8S0 150mil Adapter ADP SOIC 1601 Current Count 0 Size 80100hX8 VCC 1 80V Man Code Target Count INNO Check Sum 0390DA04h Dev Code 9 Current Failure DiMinux shareXtest 1 G rar Flash 0 7ffff OTP 800000 8000ff a Figure4 11 In the Self Test Processing screen 35 Help Commands Help Menu Help Help Hot key This option provides LABTOOL S100 help document for operating N h BRA G RO ASO 3100 230 IA LabT ool S100 software Help Index El o Menus status bar toolbar Error messages About Menu Hot key This option provides LABTOOL S100 information abo
6. a device Menu Device Verify Hot key Alt V This function compares the contents of the active device with the contents of the memory buffer It will display an error message and the address if it finds an address where the data differs It will also abort the process when this happens 28 AE1201000006 LabTool S100 Serial Flash Programmer E EX m Be Zu aaa a as AA Save Load Autoll Edit z M P M Read Blank Prog verify Erase Prot Config Option 00 00 00 68 Verify completed ID Checking Verifying at 1 8V 00 00 00 68 Verify completed Current Qty ID Checking Verifying at 1 8V 00 00 00 67 Verify completed Target Qty ID Checking 1000 gt gt Verifying at 1 8V Yerifying Total Fail Device Adapter ADP SOIC 16 Current Count Size 80100hX8 Check Sum 0390DA04h 2 0 Dev Code 1C13h Target Count Current Failure DiMinux shareXtest 1 G rar Flash 0 7fffff OTP 800000 8000f me halla For Help press Fl Figure 4 5 Device verification screen Memory Protect Menu Device Memory Protect Hot key CTRL P This function is a device specific command it appears on the main menu only after chips having this capability are selected The function must be configured before use When properly configured it can be selected and will automatically set memory protection on the chips immediately after they have been programmed Erasing a device Menu Device Erase Hot k
7. rights to the directory you want to save the file to Use another directory or disk File read incomplete The user break file format was unmatched or a disk error occurred during file reading LABTOOL S100 not found Do you want to retry The LABTOOL S100 software does not detect the LABTOOL S100 on one of the USB ports Press enter to retry or press F6 to search machine Press Esc to enter demo mode Make sure the power on the LABTOOL S100 is on Also check the parallel connection between the PC and the LABTOOL S100 If the LABTOOL S100 shares the USB port with another device remove the other device or move the LABTOOL S100 to its own port 40 LABTOOL S100 power off or disconnected from PC The LABTOOL S100 software does not detect the LABTOOL S100 on one of the USB ports Make sure the power on the LABTOOL S100 is on Also check the USB connection between the PC and the LABTOOL S100 and between the PC and the USB port If the LABTOOL S100 shares the USB port with another device remove the other device or move the LABTOOL S100 to its own port Other Error Messages The following list of error messages uses the code XXXX where XXXX can be Read Verify Blank Check Program Erase or Memory Protect Aborted has the same meaning as user break XXXX Aborted XXXXX error found XXXX error on Module X Address XXXXh APPENDIX 41 APPENDIX B Troubleshooting 42 Q amp A Q1 How to install the LABTOOL S100 sof
8. straight Hex General USB Bus Power 5V 500mA maximum 2 5W typical 1W Operation temperature 5 to 45 C 41 to 113 F Safety CE amp FCC certified Shipment Weight 0 5 Kg without module adapter Using the LABTOOL S100 Software Menus Accessing the menus can be done in two ways Use the mouse and click on the menu option displayed at the top of the screen A pull down menu will appear and you can select the option you desire by clicking on that option If you do not have a mouse available you can also use the keyboard to access the menus Press F10 to activate the main menu bar Select the sub menu that you want to use with the left and right arrow keys and press lt ENTER gt to activate the sub menu Use the up and down arrows to select an option to execute Press lt ENTER gt to execute the command Hot keys Most of the options available on the menus can also be executed by pressing the hot key associated with that option To see what the hot key is for a certain option look on the menu where the option is located If a hot key is available it will be displayed next to the option name Editor s Note See Diagram in original manual 14 amp AE1201000006 LabTool S100 Serial Flash Programmer File Project BOE Options Diagnostica Change 101010 en 9 le 5 Save Logg Mass Production Mode Blank Prog Verify Erase Prot Config Option cFeo
9. A EQUIPMENT LAADVANTECH LABTOOL S100 Serial Flash Programmer User s Manual Date 2012 3 22 Revision 1 00 00 Copyright Notice This document is copyrighted 2012 by Advantech Equipment Corp Ltd All rights are reserved Advantech Equipment Corp Ltd reserves the right to make improvements to the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Equipment Corp Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Equipment Corp Ltd assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use Acknowledgments IBM PC AT and VGA are trademarks of International Business Machines Corporation MS Windows are trademarks of Microsoft Corporation How to use this manual Thank you for purchasing the LABTOOL S100 Serial Flash Programmer We designed this manual to help you quickly and easily set up and use your LABTOOL S100 You can use the manual in two ways Step by step The manual should be used in conjunction with the On line help contained in the LABTOOL S100 software Once you ve installed the LABTOOL S100 and the software you shouldn t need this manual again You can just press Fl in the program and context sensitive help will guide you t
10. V chip in VCC and I O support The LABTOOL S100 use the 90nm FPGA chip in the hardware design it can handle the chip from 3 3V to 1 8V in VCC without special low voltage converter circuit This new technology fulfils customer s need and makes customer s investment fully protected Expansion through USB Hub and configure as a multi station asynchronous gang programmer The LABTOOL S100 interface with PC through USB interface which support USB1 1 and USB2 0 If customer needs more units in production just purchase extra LABTOOL S100 and connect those LABTOOL S100 through USB Hub up to 127 LABTOOL S100 can be attached to one PC Recommend with 4 16 units LABTOOL S100 control by one PC to avoid performance decrease Such configuration has significantly reduced the cost per station with low initial purchase cost and growth potential in future Device insertion and continuity checks No mistakes The LABTOOL S100 performs device insertion and continuity checks before programming each device It can detect poor pin contact upside down device insertion incorrect position and pin number mismatch This function protects your pocketbook by preventing expensive chip damage caused by operator error 10 Auto sensing and self programming To meet mass production requirements the LABTOOL S100 has implemented patented technology in both its hardware and software After entering the Mass production Mode the production line operator inserts a chip in t
11. anufacturer number or parts of both in the Search box Mouse 25 Click on Search Type in the characters Keyboard Press TAB until the cursor flashes in the Search box Type in the known characters All the devices that satisfy this partial information will be displayed Use the mouse to select a device and click OK If you are not using a mouse use the TAB key to skip between the various screens and use the arrow keys to move around in each screen Mass production Mode Menu Device Mass Produce Hot key Alt M The LABTOOL S100 is a mass production programmer for manufacturing When placed in mass production mode all keyboard and mouse functions are disabled and the operator needs only to insert the chips into the sockets wait until the green LED next to each socket lights up remove the programmed chips and insert new chips Anyone can do the job well without special training or skills Since all keyboard and mouse functions are disabled the possibility of errors being caused by pressing the wrong keys or changing the buffer s contents are eliminated In mass production mode the LABTOOL S100 first performs an insertion test and an ID check on newly inserted chips It then automatically programs the chip In mass production the LABTOOL S100 can be set to either of two modes standard mode or concurrent mode In standard mode LABTOOL S100 programs the devices in all 4 adapter sockets at one time Note The insertion
12. ck Sum For Help press F1 Figure 4 8 Example screen Device specific operation options The following options can be set Start address End address This is the start and the end address of the edit buffer If you want to program a certain area of a device you can change the start and end addresses accordingly This option is only displayed when the device can be programmed in this way When the end address is calculated it divides the buffer size by device bits 8 bits A 16 bit device of which the buffer size is 80 Hex will therefore have an end address of 3F When selecting a start or an end address you should align the buffer on the right boundary single word for 8 bit devices double word for 16 bit devices etc Erase start end address This option is for electronically erasable Flash chips only The default setting of this option will erase the entire chip However a user can specify ranges of blocks to be erased data in the 31 remaining blocks will be unchanged A user should reference the chip data book or configuration menu when setting the ranges of blocks to be erased Insertion Test This option performs the device insertion check of the chips in the sockets The insertion check includes poor pin contact pin count mismatch the pin count of the chip designated in the software does not match the pin count of the actual chip in the socket device in wrong position device upside down short circuit betwee
13. cted address is to be read from the buffer fill in the address that will contain the first byte into this box Buffer Size The size of the buffer to be read Load File Menu File Load File Hot key Alt L This option loads a file from disk into the memory buffer The type of files that can be loaded for a device depends on the device type Select a file to load using the mouse or type the filename in the box provided You can also type in a file spec e g hex at the Name prompt This will display all the files of the specified type and you can then select the required file to load Auto Format Detected 22 The software automatically detects the format of the file that is to be loaded If the desired format of the file differs from the format detected select the correct file format From File This option indicates which bytes must be read in the input file Select the required format To Buffer This option indicates where the byte previously read is to be written This enables you to build the memory buffer from several files From File Address If only a selected range is to be read from the input file fill in the address that will contain the first byte into this box and the size of the buffer to be read in Size To Buffer Address If the data read is to be copied into a specific area of the buffer fill in the starting address here Buffer Size This box contains the buffer size By default it is the same size as
14. d Fig3 2 You will see the Serial Programmer below the Universal Bus controllers Device Manager File Action View Help co 1ESSLI lt Ra Monitors BB Network adapters Other devices Ports COM amp LPT SR Processors Sound video and game controllers er Intel R 82801BA BAM USB Universal Host Controller 2442 Intel R 82801BA BAM USB Universal Host Controller 2444 NEC PCI to USB Enhanced Host Controller B1 NEC PCI to USB Open Host Controller gt NEC PCI to USB Open Host Controller USB Root Hub gt LISB Root Hub gt USB Root Hub gt USB Root Hub gt USB Root Hub Step4 Run the LABTOOL S100 software Fig 4 1 Select Start gt All Programs gt Advantech LabTool gt LABTOOL S100 AE1201000006 LabTool S100 Serial Flash Programmer File Project Device Options Disgnostics Help El a fele Select AutolD Edit M P M AE1201000006 Device None Type None Adapter None Pin None Current Count 0 Size None YCC None Man Code None Check Sum None Dev Code None Current Failure 0 File y mo a gt NUM 4 Target Count 1000 50 Q2 The O S can t find the LABTOOL S100 after power on Ans Step1 Install the LABTOOL S100 software If you do not have the software and you can download it from our website www aec com tw If you have installed the software skip this step Ste
15. during future programming sessions Load Project Menu Project Load Project File Hot key Alt F2 This option loads the desired project file After the project file has been loaded you can immediately program the chip using the data and setup functions selected 24 Device Commands Change Device Menu Device Change Hot key Alt C This option is used to select a new device as the active device It is important to select the correct device as the algorithms used to program devices are device specific The following screen will appear AF1201000006 LabTool S100 Serial Flash Programmer EIER File Project MEN Options Diagnostics Help ga Config Option Alt E Read Alt R Blank Check Alt B Program AltP Verify AY Memory Prot Prog Config AltY Alt K AltHU Device cFeon EN25540 850 150mil Adapter ADP SOIC 1601 Current Count 0 Size 80100hX8 VCC 1 80Y Man Code Check Sum 0390DA04h Dev Code Target Count 1000 Current Failure 0 Diflinux shareXtest 1 G rar 5 Flash 0 7fffff 0TP 800000 8000ff Max allure Change current device NUM 4 Figure 4 1 Screen for selecting Change Device 1 Select the type of device that will be the active device Mouse Click on All EPROM or Flash Keyboard Press TAB until the cursor is flashing in the Type box Use the up and down arrows to go to the appropriate type Press the space bar to select the type 2 Enter the part number the m
16. e option provides a message to the screen alerting the user to either the target quantity of chips being reached or the allowable number of failures being reached 11 For a detailed explanation of the device operation options please refer to Chapters 3 and 4 1 General Information Introduction LABTOOL S100 serial flash programmer is one 10 pin box header PC based serial flash programmer that works through PC s USB port USB1 1 USB2 0 It features small size easy operation up to 30Mbps in writing SPI flash memory chip It supports 3 3V 2 7V 2 5V 2V and 1 8V for chip in VCC and 3 byte 4 byte address of SPI flash The LABTOOL S100 is an ideal programmer for customers in DV DVD MP3 GSM Panel 3G Mobile PDA Smart Phone Internet router and others Features LABTOOL S100 Performance PC specification Core2 Duo 2 93GHz 3 5GB RAM USB2 0 and Windows XP 32 bit Following is the programming speed of LABTOOL S100 with different algorithm implement Device Chip Size Blank Programming Verifying Total Blank Check check Programming Verifying EN25S10 1M bit 0 96s 2 11s 0 95s 4 02s EN25S40 4M bit 0 985 5 12s 0 93s 7 03s MX25L1605D 16M bit 1 37s 12 31s 1 39s 16 07s MX25L6445E 64M bit 3 5s 44 93s 3 45s 51 88s MX25L12865E 128M bit 6 54s 82 89s 6 90s 96 33s MX25L25735E 256M bit 12 34s 158 98s 12 53s 183 85 1 Note 1 SPI flash with 4 bytes address 3 3V to 1 8
17. er The memory buffer contains the last file downloaded from disk into memory If no file has been downloaded from disk into memory since the LABTOOL S100 was switched on the memory buffer will contain garbage The screen that is displayed is dependent on the type of device that is currently active The purposes of the buttons displayed are as follows Radix This button controls the display of the memory address in Hex decimal format If the address is currently displayed in decimal format clicking this button will convert and display the address in Hex Fill This option is used to fill a block of memory with a specified value It needs the starting address the ending address and the value to be copied into this block of memory Copy This function copies a block in memory to a new address It requires the starting address the ending address and the address the block must be copied to Search This function searches for a specified search string It requires input of the search string to search for Undo As you make changes to the memory buffer the changes on the current page are highlighted If you choose this option it will reverse all changes made to the highlighted areas As soon as the changed memory positions move off the screen or get deselected by another command the Undo command will not undo the changes Blank checking a device Menu Device Blank Check Hot key Alt B This option checks if the active device is
18. ey CTRL E This function is a device specific command it appears on the main menu only after electronically erasable chips have been selected The function can be used to erase a desired memory range from a chip Configuration Menu Device Configuration Hot key CTRL G This function is a device specific command for a single Flash chip with a software protect block an option register configure word and lock bit The function must be configured before use When used 29 the memory protect configuration data will be burned into the chip s memory and will protect specified memory blocks AE1201000006 LabTool S100 Serial Flash Programmer File Project Device Optio Configuration En sq Pagel 00 00 00 68 Status Register Verify completed E ID Checking BP2 Verifying at 1 4 00 00 00 68 OTP sector Verify completed I OTP Lock ID Checking Verifying at 1 8 00 00 00 67 gt gt Verify completed Device cFeon Figure 4 6 Example of device specific configuration screen 30 Options Device operation options Menu Options Operation options Hot key F4 AE1201000006 LabTool S100 Serial Flash Programmer act t Configuration Save Toad Select Aui 00 00 00 68 Verify completed ID Checking Verifying at 1 8 00 00 00 68 OTP sector Verify completed I OTP Lock ID Checking Verifying at 1 8 00 00 00 67 gt gt Verify completed Device Adapter Size Che
19. hrough the processes Quick Start Our special Quick Start section gives experienced users the information they need to setup the LABTOOL S100 and software and basic guidelines on using the LABTOOL S100 If you need more information you can refer to the rest of the manual If you have any problems you can work through the manual step by step for easy troubleshooting If you have any questions feel free to call your local distributor or sales representative Software update Please visit our website at_www aec com tw to update the software Device List with Adapter Note Please visit our website at www aec com tw download LABTOOL S100_ALL pdf to search supported chip and a compatible adapter Packing list Before you begin installing your LABTOOL S100 please make sure that the following materials have been shipped e 1 LABTOOL S100 serial flash programmer e 1 USB A to mini B cable I flat cable e 1 CD ROM containing with Windows XP Vista7 x86 x64 software 1 adapter with ordering Contents VOKS teen ae 7 Ouck Starting sun ik Oni LI i ai 8 1 General Infor Mal va 9 o e hee ee Satan es 10 Features ale 10 LABTOOL S100 Profeta iaia ioni 12 Box header definiti n ENE 13 Using the LABTOOL S100 Softwares 14 2 Installahonnen ea een ae tn ame 16 Minimum PC System Requiremenisu auaaiehastas 17 Installing the LABTOOL S100 Software sense 17 Installing the LABTOOL S100 nn en nn ge 17 Updat
20. in its erased state It will return a message stating Device not blank at the first occurrence of data in the device The address where the data is found will also be displayed 27 Reading a device Menu Device Read Hot key Alt R This option reads a master chip into the memory buffer for duplication of the master chip Prior to executing this command a master socket must be designated and the master chip inserted into the master socket The default master socket is socket 0 Programming a device Menu Device Program Auto Hot key Alt P This option programs the active device with the contents of the memory buffer When the programming is complete verification will take place The type of verification depends on the verification options set in the Options Operation options menu AE1201000006 LabTool S100 Serial Flash Programmer BG E s S ss Ka s a A Save Load Autol Edit tor M P M Read Blank Prog Verify Erase Prot Config Option cFeon EN25540 8S0 150mil ID Checking Erasing Blank Checking gt gt Programming Current Qty Target Qty 1000 Total Fail Device cFeon EN25 Adapter ADP SOIC 16 Current Count 0 Size 80100hX8 Check Sum 0390DA04h de Dev Code 1C13h Target Count 1000 Current Failure Dilinux shareftest 1G rar Flash 0 7fffff OTP 800000 8000ff ALI For Help press F1 Figure 4 4 Programming progress screen Verifying
21. ing the LABTOOL S100 Software 17 3 Command Hita sol 18 LABTOOL S100 Command Hierarehy nase 19 A ESN 20 LED Display on Each Socket its en 21 LEPEcolor key ne ee AER 21 File Commands u hai air a 22 Save B ffet une ee ie see De elek st 22 Load Hile zes as esse 22 IERI 23 Projeet CE OMIM AGS iaa aa 24 SAVE Project iii dd erariali 24 Egad Project A essen alien 24 Device COMMAS ul gat RE 25 Change Device uam sn ei E EST 25 Mass production Mode alano 26 Editine the Butter ae A 27 Blank checking a device rca ria den Ks 27 Reading a device ass end 28 Programming dev ed a 28 RN 28 Memory Protect tddi dt Ged 29 Erasing a device iia ida diarias la 29 CON a dai ei 29 OPIO sc ea A 31 Device operation Options ri ia 31 Search Machines AA O A sa 33 WEAR RO 34 Diagnostics Commander RER 35 Tee 35 Help Commands ns 36 A esse RS 36 5 Using Adapters ss eee Dean 37 Adapter reguirements u ri 38 APPENDIX A Error Messages iii 39 Error MESES NER 40 APPENDIX B Troubleshooting i 42 Q1 How to install the LABTOOL S100 software nee 43 Q2 The O S can t find the LABTOOL S100 after power on 51 0 Quick Start Quick Start 0 We have a detail installing processes in Q1 of Q amp A in Appendix B page 41 1 The LABTOOL S100 must be turned off before you install its software 2 Insta
22. istic Option Select the command using the mouse or tab key or the hot key Alt T The screen shown below will appear Use the mouse or tab between screen entries Fill in the desired quantities for Target Quantity and Maximum Fail and indicate your choice for alarm enabling or disablement Select the OK button and press enter to confirm your selections Click the Reset button to set statistic parameters to default AE1201000006 LabTool S100 Serial Flash Programmer File Project Device Options Diagnostics Hel Er a G 5 a a O S Save Load Select AutoC Edit ector M P M Read Blank Prog Verify Erase Prot Config Option gt gt Found LabTool 5100 AE1201000006 Statistic Configuration X Current Count ol Es Target Count 1000 Current Failure 0 Cancel Max Failure 5 4 Statistic Alarm Disable C Enable Device cFeon EN25 Adapter ADP SOIC 1601 Current Count 1 Size 80100hx8 YCC 1 80 Man Code 381Ch Check Sum 0390DA04h Dev Code 1C13h Target Count 1000 Current Failure 0 DiMinux shareXtest 1 G rar j Flash 0 7fffff OTP 800000 8000ff Max Failure 5 For Help press F1 Figure4 10 Statistic option selection screen 34 Diagnostics Commands Self Test Menu Diagnostics Self Test Hot key F8 This option is used to self test the LABTOOL S100 Remove all devices from the modules and then press Enter to start self test function In the C
23. ll LABTOOL S100 s software 3 Turn on your LABTOOL S100 and then the O S will detect the USB device and press Continue Anyway to finish the installation 4 Run the LABTOOL S100 software 5 Select the chip type to be programmed first Use the Hot key ALT C and then type the complete part number of the chips to be programmed or use the mouse to select the correct part number 6 Load the design file into the buffer Use the Hot key ALT L then specify the origin of the file and load 7 Alternatively you can read a master chip into the buffer instead of a design file By putting a chip into adapter and performing the Read operation Hot key ALT R you can transfer the chip s contents into the buffer 8 Insert a new chip into socket set the device operation option Hot key F4 then perform Program Hot key ALT P You can now program the 4 chips simultaneously 9 To speed up throughput a user can change the mode to Mass production mode Hot Key Alt M After entering this mode the LABTOOL S100 will program chips automatically after they are properly inserted into the socket of module LABTOOL S100 only has a standard mass production mode 10 LABTOOL S100 also automatically keeps a running total of all chips that have been through programming and all chips encountering programming failures A user can input a target quantity of chips to be programmed and an allowable number of programming failures An alarm messag
24. n Edit Read Blank Check Program Verify Erase Configuration Device Information Device cFeon EN25540 850 150mil Type Flash Adapter ADP SOIC 1601 Pin 8 Current Count 2 Size 80100hX8 YCC 1 80 Man Code Target Count 1000 Check Sum 0390DA04h Dev Code 1C13h Current Failure 0 File Note Flash 0 7fffff OTP 800000 8000ff Max Failure 5 Change current device NUM Statistics 15 2 Installation Minimum PC System Requirements O S Win XP Vista and Win7 CPU PII 750 and above RAM 64 MB minimum 512 MB recommended HD 50 MB of free hard disk space Interface USB 1 1 2 0 USB2 0 recommended Installing the LABTOOL S100 Software Insert the CD into the PC s CD ROM E Drive It will execute the autorun to install LABTOOL S100 software In the file manager you can select the E LTS100 EXE and hit Enter it will create a directory called WLTS100 on your computer s C Program Files Advantech Equipment Corp Labtool S100 path and will install the LABTOOL S100 software in this directory Following successful installation and then installing the LABTOOL S100 Installing the LABTOOL S100 1 Switch the LABTOOL S 100 off 2 Install the LABTOOL S100 software 3 Connect the power adapter to the LABTOOL S100 4 Connect the LABTOOL S100 to a USB port using the USB cable supplied 5 Switch the LABTOOL S100 on 6 The O S automatically search USB device and customer p
25. n pins and chip damage Results are displayed at each socket s LED Device ID Check This option performs a device signature and manufacturer match test With the chip selected and plugged into a socket LABTOOL S100 checks the device ID and displays the results of each check on the LED display Verify Passes Checking this option will instruct the LABTOOL S100 to perform device verification with the buffer data when programming is complete When verify passes is enabled one of the three verify options as described below must be set Verifying Options The following three options are available for verification of data retention following programming verify twice with 5 Vo verify twice with 10 V_ and verify once with V c These options will only be enabled if the Verify passes option see above is enabled e Twice V 5 When this option is selected the LABTOOL S100 will do two verify passes on the device one using Voc 5 the other Voo 5 Example IF Vis 3 3 V the LABTOOL S100 will do one verify pass using a V of 3 465 V and one using a Vo Of 3 135 V e Twice V 10 When this option is selected the LABTOOL S100 will do two verify passes on the device one using Vcc 10 the other Vcc 10 32 Search Machine Menu Options Search Machine Hot key F6 This option is used to search LABTOOL S100 in which USB port and software When you turn the LABTOOL S100 off and then on you have to use thi
26. o the adapter module the LED on the LABTOOL S100 indicates the chip is busy or good or error the operator follow the LED and take necessary action to remove or insert the chip No formal training is needed In addition the LABTOOL S100 s auto sensing feature ensures the chip inserted correctly and automatically programs the chip without press any key Furthermore in the Mass production mode the system module the system keyboard is automatically disabled to prevent any inadvertent mistakes Project file Save and Load You can save the program configuration project file which contains the device selection the buffer data and all of the program setup options This file can be recalled at any time for future use without having to go through the setup procedure again This allows you to pass your design file to the production department without mistakes You can also read the data from a chip into the buffer from any of 4 adapter modules according to your specification Target quantity and maximum failure rate alarm The LabtTool T400 automatically keeps a running total of all production pieces attempted and all production pieces failed Users can input a target quantity of chips to be programmed and an allowable number of failures An alarm function can be enabled to send a message to the screen alerting the user to either the target quantity of chips being reached or the allowable number of failures being reached 11 LABTOOL S100 Profile
27. ogrammer If your hardware came with an installation CD 222 or floppy disk insert it now What do you want the wizard to do O Install from a list or specific location Advanced Click Next to continue Ca tea 47 Fig 2 3 Installing Found New Hardware Wizard Please wait while the wizard searches 48 Fig 2 5 Press Finish Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for Serial Programmer gt Click Finish to close the wizard Step3 Select Start gt Control Console gt System gt Hardware gt Device Manager and you will see the AEC LABTOOL S100 Turbo Flash Gang Programmer Fig 3 1 Press Device Manager System Properties System Restore Il General Device Manager o The Device Manager lists all the hardware devices installed on your computer Use the Device Manager to change the gt properties of any device Device Manager i Driver Signing lets you make sure that installed drivers are compatible with Windows Windows Update lets you set up how windows connects to Windows Update for drivers Driver Signing Windows Update Hardware Profiles a Hardware profiles provide a way for you to set up and store different hardware configurations Hardware Profiles ae a Automei Updates Updates _ Remote Computer Name Hardware Advance
28. p2 Turn the LABTOOL S100 power on Step3 Select Start gt Control Console 3 System gt Hardware gt Device Manager You will see an USB Device in your PC Step4 Uninstall the USB Device Step5 Turn the LABTOOL S100 power off Step6 Turn the LABTOOL S100 power on and then the OS found out a new USB device from your USB interface Step7 Select Start gt Control Console gt System gt Hardware gt Device Manager and you will see the Serial Programmer Step8 Run the LABTOOL S100 software Note Recommended O S in your PC 1 Windows XP 32 bit 2 Windows XP 64 bit 3 Vista 32 bit 4 Vista 64 bit 5 Windows 7 32 bit 6 Windows 7 64 bit SI
29. ress Continue anyway during installing Updating the LABTOOL S100 Software We provide quarterly formal releases of the LABTOOL S100 software on our website Monthly temporary releases are also available on our website Please download releases from our website at www aec com tw 3 Command Hierarchy LABTOOL S100 Command Hierarchy File ALT F Project ALT J Device ALT D Options ALT O Diagnostics ALT I Save Buffer Load File Exit Save Project Load Project Change Mass Produce Edit Read Blank Check Program Verify Memory Prot Prog Config Erase Configuration Operation Module Options Search Machine Statistic Self Test ALT S ALT L ALT X ALT FI ALT P2 ALT C ALT M ALT E ALT R ALT B ALT P ALT V Ctrl P Ctrl E Ctrl G F4 F5 F6 F7 F8 19 4 Operation 20 LED Display on Each Socket Each of 4 adapter modules in the LABTOOL S100 has a tri color LED display to indicate the status of the socket Read this section carefully to avoid damage to chips Warning Do not insert or remove a chip from a socket while the socket LED is yellow LED color key Blank the adapter module is not active Green the adapter module is active or the last operation result passed Yellow the adapter module is busy don t do anything until the LED turns Green or Red Red the last operation resulted in failure the socket is active and awaiting another operation Flashing LED
30. s option to search an unassigned LABTOOL S100 for controlled by present software AE1201000006 LabTool S100 Serial Flash Programmer File Project Device Options Diagnostics Help Eb E xs E wa is a A Save Load Select Auto vector MP M Read Blank Prog Verify Erase Prot Config Option gt gt Found LabTool 5100 AE1201000006 Device cFeon EN25S40 8SO 150mil Adapter ADP SOIC 1601 Current Count Size 80100hX8 VCC 1 80 Man Code ESTATE Check Sum 0390DA04h Dev Code 9 Current Failure DAlinux share test 1 G rar 5 Flash 0 7fffff OTP 800000 8000ff ST NUM 4 Figure 4 9 After Search Machine selection 33 Statistic LABTOOL S100 can keep track of chip programming failures The lower right hand corner of the Run Time Viewer screen contains two entries Current Quantity and Total Fail These quantities automatically increment for every chip LABTOOL S100 attempts to program and for every programming failure Failures counted include chips that fail device ID check blank check verify pass protect and unprotect The user can input a target quantity of chips to be programmed in a production run and an allowable number of failures An alarm feature can be set so that when the target quantity or the allowable failures is reached an alarm message is displayed on the screen to alert the operator Menu Options Statistic Hot key F7 This command controls the setting of the Stat
31. test must be enabled to use mass production mode AE1201000006 LabTool S100 Serial Flash Programmer EH SE EE TE TEPPE IKE Save Toad Select M P M Read Blank Prog Verify Erase Prot Config Option gt gt Found LabTool 5100 AE1201000006 Standard Mass Production Mode Current Qty quer Jets Tartget Qty i Total Fail MIT Device cFeon EN25 Adapter ADP S01C 16 i Ignore Current Count Size 80100hX8 moror Check Sum 0390DA04h Dev Code 1C13h Benennung Current Failure DiMinux share test 1 G rar Flash 0 7fffff OTP 800000 8000ff Max Falll es For Help press Fl 26 Figure 4 2 Standard mass production mode screen An insertion timer is included for use with the insertion test When a chip fails an insertion test and the insertion timer is disabled the LABTOOL S100 will alert the operator to the failure and require either that the problem be corrected or that the operator acknowledge the failure before continuing with programming When a chip fails and the insertion timer is enabled the LABTOOL S100 waits the amount of time set into the insertion timer This is to give the operator time to correct the error If the error is not corrected in time the error socket shuts down and all the devices in good sockets are programmed The insertion timer default time is 5 seconds Editing the Buffer Menu Device Edit Hot key Alt E This function is used to edit the memory buff
32. the device size If you want to download a file into memory that is bigger than the active device insert the size here or in Options Operation Options Clear Buffer Before Loading the file Four options are available during memory buffer data loading The default option is to clear the buffer to its blank state prior to data loading Disable This option leaves the original buffer data unchanged but then overwrites it with the contents of the newly loaded file Clear buffer with blank state This option clears the buffer to the device blank state using command 00 or FF depending on device selection then overwrites the buffer during file loading Clear buffer with zeros 0x00 First clears the buffer of its contents using command 00 then overwrites the buffer with the new file contents Clear buffer with ones 0xFF First clears the buffer of its contents using command FF then overwrites the buffer with the new file contents Exit to Windows Menu File Exit Hot key Alt X Quit the LABTOOL S100 program and exit 23 Project Commands Save Project Menu Project Save Project Hot key Alt F1 This option saves the current setup of the LABTOOL S100 software into a project file The file includes devices selected buffer data operation options setup and device configuration setup You can also attach a footnote to this project file The project file acts as a macro eliminating the need to go through each procedure
33. tware Ans Step1 Install the LABTOOL S100 software If you do not have the software and you can download it from our website www aec com tw If you have installed the software skip this step Step2 Turn the LABTOOL S100 power on Step3 Select Start gt Control Console gt System gt Hardware gt Device Manager and you will see the Serial Programmer Step4 Run the LABTOOL S100 software Note Recommended O S in your PC 1 Windows XP 32 bit 2 Windows XP 64 bit 3 Vista 32 bit 4 Vista 64 bit 5 Windows 7 32 bit 6 Windows 7 64 bit 43 Step1 Install the LABTOOL S100 software If you do not have the software and you can download it from our website www aec com tw If you have installed the software skip this step Fig 1 1 Install MicrosoftVistual C 2010 Redistributable Pacage x86 i Labtool 5100 Software requires the Following items to be installed on your computer E Click Install to begin installing these requirements Pending Microsoft Yisual C 2010 Redistributable Package x86 Fig 1 2 Press Next Welcome to the InstallShield Wizard for Labtool 5100 Software The InstallShield Wizard will install Labtool 5100 Software on your computer To continue click Next Fig 1 3 Press Next 44 Choose Destination Location Select folder where setup will install files i J Install Labtool 5100 Software to CA Advantech Equipment Corp SLabtool 5100
34. ut software version website and supporting OS and USB driver version About LabTool S100 Labtool S100 Software Help Index Using LabTool S100 Serial Flash Programmer Using Help The online help that is built into the LabTool S100 is context sensitive In other words if you want help on the File Save command select the File Save command on the menu and press Fl to view the help LabTool S100 operation hints Using a mouse Using a mouse is the easiest way to control the LabTool S100 To select any option menu just move the cursor to the option menu and press the left mouse button The mouse can also be used to cancel initiate operations Just click the appropriate option Note In certain contexts the next operation cannot be selected until the current operation is complete cancelled Tocina tha Lavhnard Help About WLabTool 5100 for Windows XP Yista 7 Ver 1 00 00 LS erial Flash Programmer Copyright C 2012 Advantech Equipment Corp http www aec com ha USB driver version 0 02 08 17 5 Using Adapters 37 Adapter requirements The LABTOOL S100 supports 10 pin box header connecter You will need to order an adapter for your chip package You can order the following available adapters to fit your needs Other adapters will become available after release of new chips We have a device list and adapter note please reference http www aec com tw download LABTOOL S100_ALL pdf