Home
XS-Fitting Pro
Contents
1. Anti tamper monitoring Available Number of Permissions Depends on the access control system Reader systems The following reader systems are available depending on the model MIFARE Classic DESFire LEGIC prime advant e Transmission frequency 13 56 MHz e Read range 2 cm 1 HITAG HITAG1 HITAG2 EM4102 EM4150 in pipeline e Transmission frequency 125 kHz e Read range 2 cm 1 1 With reference ID card in credit card format Compliance with ETSI EN 300 330 Ambient Conditions Operating temperature 5 C to 50 C Storage temperature 20 C to 70 C Humidity O to 80 non condensing Tested to DIN IEC 60068 2 1 2 3 Protection rating IP30 Dimensions 66 x 248 x 79 2 w x h x d 2 Depends on handle fitted Colour Stainless steel look front anthracite Weight 1 800g including batteries Door dimensions Door thickness 32 105 mm Backset gt 35 mm Centres distance 72 92 mm General Design Device with internal power supply as per EN 60950 1 Human exposure to electromagnetic fields as per EN 50364 and EN 62479 Use of the device is permitted in the countries listed below ISO 3166 Code CE We reserve the right to make technical modifications and improvements to promote the progress of our equipment DORMA Time Access GmbH PO box 21 01 85 e D 53156 Bonn e Mainzer Stra e 36 52 e D 53179 Bonn Phone 49 0 2 28 85 54 0 e Fax 49 0 2 28 85 84 1 75 e www dorma time access
2. tion doors This is indicated on the nameplate E 4 4 nameplate Cade Hande Installation at Fire and Smoke Protection Doors permitted Y es pe BL 0 D PX 4x Mignon 1 5V XXXXXXXX XXXXX XXX XX Installation is only permitted in combination with a fire protection kit The installation is described in separate Instructions supplied with the fire protection kit Proof of suitability in conjunction with the fire or smoke protection is reguired Fire smoke protection kit NN i Instruction Fire protection kit a e o CC N 10 XS Fitting Pro 2 Assembly DORMA 2 3 Mounting plate 2 3 1 Long backplate screwed through Use only countersunk screws to fasten the mounting plate The screws may not protrude beyond the surface of the mounting plate If installed improperly the batteries can be damaged and thereby cause high discharge currents to arise Risk of excessive heat explosion and fire 11 XS Fitting Pro 2 Assembly 2 3 1 Rose screwed through Use only countersunk screws to fasten the mounting plate The screws may not protrude beyond the surface of the mounting plate If installed improperly the batteries can be damaged and thereby cause high discharge currents to arise Risk of excessive heat explosion and fire 12 XS Fitting Pro 2 Assembly DORMA 2
3. normal household waste We the manufacturer will take back our electric and electronic products and dispose of them for you free of charge Correct disposal of your old equipment protects people and the environment from possible harmful consequences Batteries This device requires alkaline batteries for operation According to European directive 2006 66 EC disposable and rechargeable batteries must not be disposed of with normal household waste Please check your local regulations for separate disposal of batteries Correct disposal of batteries protects people and the environment from possible harmful consequences XS Fitting Pro DI 1 General 1 4 Functional Description XS Fitting Pro can be installed in place of the door fitting and put into operation without the need for any wiring The power supply is provided by batteries XS Fitting Pro reads ID card data using a contactless pro cess XS Fitting Pro authorisations are checked in different ways depending on the type of operating mode The different operating modes are as follows Offline In offline mode an internal database is used to check authorisations Access on Card AoC Access permissions are saved onto the ID card The ID card user retrieves the current permissions from a central online AoC station and these permissions are then transmitted to the ID card 1 5 Package Contents A 1x XS Fitting Pro B 1x Cylinder with key A DORMA
4. de DORMA GmbH Co KG PO box 40 09 e D 58247 Ennepetal e DORMA Platz 1 e D 58256 Ennepetal Phone 49 0 23 33 793 0 e Fax 49 0 23 33 79 34 95 e www dorma com
5. is unlocked at the beginning and locked again automatically at the end of this period Permanent release cannot be influenced by users In this case the door remains unlocked during the entire period 18 XS Fitting Pro u 5 Maintenance DORMA 5 1 Batteries 5 1 1 Changing the batteries 1 Remove the XS Fitting Pro from mounting plate 2 Change the batteries Check the polarity of the batteries 3 Put the XS Fitting Pro on the mounting plate and lock Only ever use unused brand new batteries In order to ensure that the system operates without problems we recommend that only batteries of type Energizer Ultra 1 5V be used Rechargeable batteries and disposable batteries with differing voltage must not be used 19 XS Fitting Pro W 5 Maintenance Do not use electrically conductive tools to insert remove the batteries If the batteries are handled improperly high discharge currents can arise Risk of excessive heat explosion and fire 3 1 Open up the bracket 3 2 Pull on bracket gently so that you can remove the batteries The grub screw 3 5 must be tightened with a torgue of 0 8 Nm The battery status must be reset in XS manager after the batteries have been replaced 3 20 XS Fitting Pro i 5 Maintenance DORMA 5 1 2 Battery warnings The XS Fitting Pro uses a series of changing signals during the opening process to indicate that the batteries capacit
6. mit Europrofil Zylindern oder in T rschl sser mit Schweizer Rundprofil vorgesehen Zum konfigurieren des XS Zylinders Pro oder generell zur Kommunikation mit einer bergeordneten Zentrale ist der XS Zylinder Pro mit einem Funkmodul ausgestattet Ausstattung Nahfeldieser Mifare DESFire Legic Advant 13 56 MHz Ab Serien Nummer 0406630001 Ger teklasse Funkanlage der Klasse 2 Frequenzband 865 0 870 0 MHz Non Specific Short Range Device Unterklasse 13 553 13 567 MHz Mifare DESFire Legic Advant Inductive applications erkl rt hiermit die Ubereinstimmung der nach oben genannter Bezeichnung und Ausstattung gefertigten Exemplare unter Voraussetzung der bestimmungsgem en Verwendung mit den wesentlichen Schutzanforderungen folgender Richtlinie des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten der EG Richtlinie Datum Titel 1999 5 EG 03 1999 Funkanlagen und Telekommunikationsendeinrichtungen und die gegenseitige Anerkennung ihrer Konformit t kurz R amp TTE Richtlinie Die Konformit t wird in Bezug auf folgende angewandte harmonisierte Europaische Normen erklart Fundstelle Ausgabe Richtlinienbezug datum EN 60950 1 A12 2011 02 1999 5 EG R amp TTE Richtlinie Artikel 3 1 a Gesundheit und Sicherheit EN 50364 2001 10 1999 5 EG R amp TTE Richtlinie Artikel 3 1 a Gesundheit und Sicherheit EN 62479 2010 09 1999 5 EG R amp TTE Richtlinie Artikel 3 1 a Gesundheit und Sicherheit EN 30148
7. or 9 mm latch pins may be used The latch pin should extend 35 mm into the handle on the other side 2 1 4 Backset b The backset must be at least 35 mm If the backset for the XS Fitting Pro is too small there is a danger that the body of the XS Fitting Pro can come into contact with the rebate 2 1 5 Centre to centre dimension c With the XS Fitting Pro the centre to centre dimension may vary between 72 and 92 mm The IBL I interior plates are only suitable for centre to centre dimensions of 72 mm or 92 mm For other dimensions roses must be fitted 72192 88 XS Fitting Pro 2 Assembly 2 1 6 Opening direction Depending on the model XS Fitting Pro is suitable for use on both left handed and right handed doors The handle direction depends on the model used and cannot be changed at a later stage DIN right DIN left Handle right DR Handle left DL XS Fitting Pro 2 Assembly DORMA 2 2 Preparation Use the drilling gauge to drill the mounting holes 2 2 3 Drilling gauge 1 Remove the existing handle and profile cylinder 2 Set centres distance 3 Drill centring holes 4 Remove drilling gauge and lock 5 Fasten drilling gauge into place XS Fitting Pro 2 Assembly DORMA 2 2 2 Installation on Fire and Smoke Protection Doors nameplate Only XS Fitting Pro s with fire protection hand N les may be installed on fire and smoke protec
8. 3 1 Long backplate or rose not screwed through We recommend screwing through simple doors such as those made with a flaxboard core Use only countersunk screws to fasten the mounting plate The screws may not protrude beyond the surface of the mounting plate If installed improperly the batteries can be damaged and thereby cause high discharge currents to arise Risk of excessive heat explosion and fire 13 XS Fitting Pro w 2 Assembly 2 4 Final assembly 14 Only ever use unused brand new batteries In order to ensure that the system operates without problems we recommend that only batteries of type Energizer Ultra 1 5V be used Rechargeable batteries and disposable batteries with differing voltage must not be used Do not use electrically conductive tools to insert remove the batteries If the batteries are handled improperly high discharge currents can arise Risk of excessive heat explosion and fire XS Fitting Pro 2 Assembly DORMA N During fitting make sure that no components are damaged The grub screw 5 5 must be tightened with a torgue of 0 8 Nm XS Fitting Pro 3 Commissioning 3 1 Initialisation In order to put the XS Fitting Pro into operation a netbook with a USB RF Stick and installed XS Manager is required The XS Fitting Pro must be configured and initialised bef
9. 9 1 2008 04 1999 5 EG R amp TTE Richtlinie Artikel 3 1 b Elektromagnetische V1 8 1 Vertraglichkeit EN 301489 3 2002 08 1999 5 EG R amp TTE Richtlinie Artikel 3 1 b Elektromagnetische V1 4 1 Vertraglichkeit EN 300220 2 2010 02 1999 5 EG R amp TTE Richtlinie Artikel 3 2 Effektive Nutzung des V2 3 1 zugewiesenen Funkspektrums EN 300330 2 2010 02 1999 5 EG R amp TTE Richtlinie Artikel 3 2 Effektive Nutzung des V1 5 1 zugewiesenen Funkspektrums CEO Bonn 18 04 2012 B Schuck Senior Department Manager 22 EG Konformit tserkl rung XS Fitting Pro wll EC Declaration of Conformity DORMA CE Declaration de conformite 125 kHz in pipeline 23 6 Technical Data XS Fitting Pro Power supply 4 Batteries Energizer Ultra LR6 1 5 V Battery Operating life at room temperature 20 C Typical number of locking cycles 30 000 Typical operating life when not operated 4 years The specified number of cycles relates to the times that the UID from the respective ID card type is read Different configurations of reader properties may reduce the number of cycles by up to 40 Data Retention 10 years without battery Date time Clock buffering when battery replaced usually 1 minute Clock drift at room temperature 10 minutes year At 5 C and 65 C 50 minutes year Wireless Interface 865 870MHz Range max 10 m Compliance with ETSI EN 300 220 Signalling 1 x LED red green blue yellow
10. DORMA o Installation Manual XS Fitting Pro DORMA XS Fitting Pro l Genetali vastas naaa era 3 ECO A eh AKKA EE 4 1 2 Further Sources of Information s s ssi 4 L 3 DI AA R KK 2 aoe koh SSA as 4 1 4 Functional Discription is ss ss Ps Rs ev amp ara 5 1 5 Package Comten i di wea dee E EE min 5 1 6 Required for Installation 6 2 ASSEMbly cesos tee eee ee eee nei 7 2 1 Door requirementS 000 cece eee eee 7 2 2 Preparato s gt Se ee Snes ec ene we Seren a as 9 2 3 Mounting Plate 2545848406 80848 ran 13 2 2 Final assembly sau ae ed Be ew Oe Aaa we a 14 3 Commissioning ls 15 SL NLA ONE eg ren Rene eGo ws US 16 3 2 Establishing Wireless Connection 16 3 3 Optical SIgnals 400000 armani 17 4 Operation 18 5 Maintenance aaaaa aaa 19 gdl Batler o e en e det 19 5 2 lamper dla si aa aaa a 21 EC Declaration of Conformity 22 6 Technical Data 24 XS Fitting Pro Gi 1 General DORMA The information provided in these installation instructions Despite every effort to prevent mistakes they can never may be modified without prior notification be completely avoided Therefore we would be grateful to All previous versions cease to be valid with the publication receive notification of any errors or omissions of these instructions DORMA accepts no liability for the information included The information in these install
11. Online In online mode XS Fitting Pro is connected to an access control terminal via the XS Traffic Point radio node Permissions are checked by the access control terminal If the check proves positive the door handle is unlocked When in standby mode or if the booking is negative the door handle remains blocked and the door remains locked Data reconciliation for offline mode and initialisation is performed via a wireless interface Communication with this interface is via a netbook or notebook The XS Manager communication software installed on the netbook allows data to be exchanged between XS Fitting Pro and the access control software on the PC host C 1x Manual XS Fitting Pro BI 1 General 1 6 Required for installation Z 1 1x battery set order no 19000070400130 Z 5 lx screw clam Z 2 lx installation kit depending on door thickness Z 6 Netbook with XS Manager Z 3 1x drilling gauge order no 19191400 Z 7 USB RF Stick order no 1900070402707 Z 4 1x Allen key 2 mm Z 8 Fire smoke protection kit order no 19167498 2 Z 3 Er Z 1 i 5 7 N Ir N I sx T Ja Ara 3 x ITT y N Ax A 9 oO eS SAN Z 4 Z 5 S XS Fitting Pro 2 Assembly DORMA 2 1 Door reguirements 2 1 1 Door thickness 32 105mm 2 1 2 Profile cylinder For an XS Fitting Pro without profile cylinder bore the pro file cylinder may protrude up to 17 mm 2 1 3 Latch pins a 8 mm
12. ation instructions has been in this document being free of protected third party rights compiled in good faith and based on the best knowledge DORMA does not provide any licences for its own or third available to us DORMA accepts no liability for the correct party patents or other protected rights with this document ness and completeness of the details provided In particular DORMA cannot accept liability for any consequential damages due to incorrect or incomplete infor mation The recommendations for installation made in this manual are based on the assumption that prevailing basic conditi ons are favourable DORMA accepts no liability for the perfect functioning of XS Fitting Pro in external non system environments This manual or sections of it may not be reprinted copied or distributed to third parties other than for your own use without he approval of DORMA Time Access GmbH All rights reserved DORMA Time Access GmbH Postfach 21 01 85 53156 Bonn http www dorma time access de E Mail info dorma time access de Copyright 2012 by DORMA Time Access GmbH Z Nr 1099G 00 B EN Stand 03 13 V1 30 XS Fitting Pro m 1 General 1 1 Correct Use The XS Fitting Pro is a mechatronic access control unit for installation on internal doors Mandatory legal regulations must be observed and may mean that use on doors that are subject The XS Fitting Pro may only be used for opening doors to special requirements is no
13. ction Connection with XS Manager After the supply voltage has been put on Power On Motor blocked The XS Fitting Pro was removed from the mounting plate This signal ceases after the XS Fitting Pro is replaced Tampering attempt Launching De launching only by Legic reader system PX51 17 XS Fitting Pro 4 Operation DORMA 4 Operation Use with badges with lock permissions cards or transponder tags 4 1 Standard access function Hold the badge in Front of the XS Fitting Pro The door handle is unlocked for the programmed door open time and then locked again automatically During this time the door can be opened using the door handle in the usual Way 4 2 Office release If the office release function is set in the access programme of the XS Fitting Pro for a specified period this function can be activated for that particular period by holding a badge with the relevant authorisation to the XS Fitting Pro for approx 3 seconds During these 3 seconds the green LED flashes twice The door remains unlocked until the programmed time and then locks automatically 4 3 Reset office release During the office release time the door can be locked again by holding a badge with the relevant authorisation to the XS Fitting Pro It remains possible to re activate office release within the programmed office release time 4 4 Permanent release If permanent release is programmed for a period the door
14. ore It can be put into operation In order to do this the door must be created in the host system and the data synchronised with XS Manager During initialisation the XS Fitting Pro is assigned a unique identification number Once the XS Fitting Pro has been initialised you need to upload access data such as ID card numbers of authorised ID cards from the host system The XS Fitting Pro is then ready for use Manual XS Manager 3 2 Establishing Wireless Connection You first need to start the XS Manager application which will search for all available XS Fitting Pro and list them You can then select an XS Fitting Pro from this list The selected XS Fitting Pro can be indicated by A blue flashing light indicates connection with XS Manager Manual XS Manager 16 XS Fitting Pro 3 Commissioning DORMA 3 2 Optical Signals a e flashes a R red G green x ae B blue lights up Y yellow about 100ms Signalling Note S Positive booking Access is granted Positive booking in Battery Warning Level 1 Access is granted Positive booking in Battery Warning Level 2 Access is delayed 3 sec Positive booking in Battery Warning Level 3 Access is delayed 6 sec Negative booking Access is denied Access is granted Office released permanently Office released ended Shows which cylinder XS Manager is currently addressing Selected for wireless connection Wireless conne
15. t permitted gt Installation on fire and smoke protection doors is only permitted with components approved by DORMA and a separate fire protection kit Proof of suitability in conjunction This device is categorised as class 2 radio equip with the fire or smoke protection door concerned is required ment according to R amp TTE directive 1999 5 EC The frequency bands are not harmonised Installation in the direction of escape on emergency and In some countries use may not be permitted or escape doors is not permitted may be subject to restrictions However it can be used as an outside access device in con Cf Technical Data junction with emergency exit door latches i e installation against the direction of escape on doors along escape and rescue routes Proof of suitability for use with the respective emergency exit door latch is required for use as an outside access device gt Use for any other purpose than that described is not permitted 1 2 Further Sources of Information Further documents are available on request User Manual XS Manager Describes the configuration of the XS components 1 3 Disposal The device was manufactured using recyclable materials and components When disposing of the device and the packaging please ensure environmentally friendly recycling Information for EU Countries European Directive 2002 96 EC applies to this device This means that this product must not be disposed of with
16. y will soon no longer be sufficient to ensure proper operation There are three warning levels First warning level When a badge is held in front of the XS Fitting Pro the lock permission is issued as programmed The LED will light green and subseguent flash reed four times when the door is unlocked Second warning level If the battery capacity is further reduced then there will also be a delay of 3 seconds before the XS Fitting Pro unlocks the door The signal is the same as stage 1 Third warning level If the battery capacity is further reduced then there will also be a delay of 6 seconds before the XS Fitting Pro unlocks the door The signal is the same as stage 1 Access is granted Batteries must be replaced immediately with new ones as soon as any of the battery warnings occurs Access is delayed 3 sec Access is delayed 6 sec 5 2 Tamper alarm If the XS Fitting Pro is removed from the mounting plate a visual alarm signal is emitted This signal ceases after the XS Fitting Pro is replaced 21 EG Konformit tserkl rung XS Fitting Pro wll EC Declaration of Conformity CE Declaration de conformite DORMA Time Access GmbH Mainzer Stra e 36 52 53179 Bonn Germany als verantwortlicher Hersteller f r das nachfolgend bezeichnete Erzeugnis Bezeichnung XS Beschlag Pro Bestimmungsgem e Der XS Zylinder Pro ist eine elektronische Schlie einheit zum Einbau Verwendung in DIN T rschl sser