Class II, Type A2 and B2 Biological Safety Cabinets

image

Contents

1. ernal Dimensio 1115x852 Xx 10 mm 1 20x852 x 10m 1725x852 x 1540 mm 2030 x 852 x 1540 mm 2600 x 852 x 1610 mm D 44 0 x 33 5 x 60 6 Do0 2x32 5 X60 G 63 0 x 33 5 X606 80 0 x335 X006 1024x335 XOJA O ernal Dimensio 970 x 623 x 670 mm 1270 x 623 x 670 mm 1570 x623x670mm 1870x623x6 0mm 2440 x 623 x 670 mm D 38 2 x 24 5 x 26 4 50 0 x 24 5 x 26 4 61 8 x 24 5 x 26 4 73 6 xX 24 5 x26 4 96 0 x 24 5 x 26 4 able Work Area 045 m 738 sate 0 6 m 6 5 Sr 0 75 M 1 STi 0 9 m 9 7 sq ft 1 2 m le Sait ested Ope O 229 mm 9 229 mm 9 229 mm 9 203 mm 8 203 mm 8 O g Opening 274 mm 10 8 274 mm 10 8 274 mm 10 8 248 mm 9 8 248 mm 9 8 ur aia va Inflow 0 53 m s 105 fpm oe Downflow 0 35 m s 70 fom 0 35 m s 70 fom 0 35 m s 70 fpm 0 33 m s 65 fom 0 33 m s 65 fom Inflow AZ Aim in 2 5 etm 55am 7 326 cm 686 m h 406 cfm 724 m h 426 cfm 945 m h 560 cfm Downflow 628 m h 363 cfm 822 m h 476 cfm 1016 m3 h 588 cfm 1210 m h 700 cfm 1579 m h 914 cfm Exhaust aA m h 251 amm 555 ii Mio26 Gim 686 m h 406 cfm 724 m h 426 cfm 945 m h 560 cfm Nirflo E Required Exhaust With Optional Thimble 529 m h 3811 cfm 764 m h 450 cfm 1116 m h 657 cfm 1164 m h 685 cfm 1540 m h 913 cfm Exhaust Collar Static Pressure For Optional Thimble 32 Pa 0 12 in FLO 49 Pa 0 19 in H O 62 Pa 0 24 in H O 79 Pa 0 31 in H O 100 Pa 0 40 in H O Exhaust Collar PA er Typica e
2. Available in 0 9 1 2 1 5 1 8 and 2 4 meter models 3 4 5 6 and 8 Shown with optional telescoping stand Angled Drain Pan Easy to clean G cen z Does not harbor contaminants n SFDA k EN12469 NSF 49 UL 61010 JIS K3800 SFDA YY 0569 EN 12469 SANS 12469 Esco Labculture Class II Type A2 LA2 has passed more performance tests in more languages for more certifications throughout more countries than any other biological safety cabinet in the world Labculture LA2 Class Il Type A2 LB2 Class I Type B2 Biological Safety Cabinets FEATURING ADVANCED MICROPROCESSOR CONTROLLER Pressure Switch LB2 on ly m Night Setback mode to further reduce power consumption by 60 m Temperature independent m Fast response p _ Energy Efficient ECM Motor m Powered by latest generation ECM motor that is more efficient than legacy ECM and VFD motors 70 Energy savings compared to AC motor Stable airflow despite building voltage fluctuations amp filter loading Input Voltage BSC with ECM amp VFD Conventional AC motor motor voltage fluctuation airflow fluctuation Esco LA2 E LR2 E Competitor N Esco ECM motor Competitor B Um Tin T 100 200 300 stable motor voltage stable airflow ULPA Filter mi 70x Filtration efficiency of HEPA filter mi Creates ISO Class 3 work zone instead of industry standard ISO Class 5 Typical Penetration R gt Labculture
3. Esco cabinets use ULPA filters per IEST RP CC001 3 instead of HEPA filters in common BSC HEPA filters offer 99 99 typical efficiency at 0 3 micron while ULPA filters provide 99 999 typical efficiency for particle sizes of 0 1 to 0 3 micron 0 15 0 20 0 25 0 30 0 40 Particle Size um Dynamic Chamber m Blower plenum and side walls are surrounded by negative pressure mi Prevent contaminants from escaping outside Positive pressure I Negative pressure ISSCISE powder coat m Silver ion impregnated powder coat Inhibit microbial growth to improve safety Bacterial Population 10 folds 4 hours 8hours 12hours 16hours 20hours 24 hours Contact Time in Hours The Most Certified BSC in the World Biosafety Cabinets Air Quality Filtration Electrical Safety Standards NSF ANSI 49 USA ISO 14644 1 Class 3 Worldwide EN 1822 H14 Europe UL C 61010A 1 USA EN 12469 Europe JIS B9920 Class 3 Japan IEST RP CC001 3 USA CSA22 2 No 1010 192 Canada JIS K 3800 Japan JIS BS5295 Class 3 Japan IEST RP CC 007 USA EN 61010 1 Europe SFDA YY 0569 China US Fed Std 209E Class 1 USA IEST RP CC034 1 USA IEC61010 1 Worldwide Compliance The NSF ANSI 49 certified models are LA2 4A1 E LA2 4A2 E LA2 4A3 E LA2 5A1 E LA2 5A2 E LA2 5A3 E LA2 6A1 E LA2 6A2 E LA2 6A3 E LB2 4B1 E LB2 4B2 E LB2 4B3 E LB2 5B1 E LB2 5B2 E LB2 5B3 E LB2 6B1 E LB2 6B2 E and LB2 6B3 E ECCO WORLD CLASS WORLDWIDE
4. Hr 2317 BTU ar 2795 BTU Hf 3184 BTU Hr 2573 BIU Hr O al Power Co ptio 166 W 189 W 229 W 252 W 345 W et Weig 279 kg 615 Ibs 317 kg 699 lbs 359 kg 791 lbs 438 kg 966 lbs 591 kg 1304 Ibs oping Weig 318 kg 703 lbs 370 kg 814 lbs 402 kg 886 lbs 491 kg 1083 Ibs 651 kg 1435 lbs pping Dimensio a 1210 x 950 x 1950 mm 1520 x950 x 1950 mm 10900 x 950x 1950 mm 2150 x 950 x 1950 mm 2720 x 950 x 1950 mm D 47 6 x 37 4 x 76 8 BIS KIA Xe 74 8 X 37 4 x 76 8 OA KIVA 768 107 0 x374 X 708 oping Vo e Ma 224 ime 9 UFE 2 82 m 99 6 cu ft 3 52 MP i243 cue 393m 406 cuit 5 04 me 173 0 cut Height includes exhaust collar and depth includes the remove able arm rest and front cover When they are removed depth is 790 mm 31 1 This Concurrent Balance Value CBV Exhaust Volume per Pitot Duct Traverse and Static Pressure at cabinet exhaust connection should be used when sizing the HVAC exhaust amp supply This minimum exhaust static pressure for clean exhaust filter should not be used for exhaust fan sizing and it is listed here for comparative purpose only Noise reading at open field condition anechoic chamber Cabinet only excludes optional stand Power Rating Voltage VAC Frequency Hz Example Class Il Type B2 can be used to handle volatile toxic chemicals and _ radionucleotides because by default 230 50 LB2 4B1 it s hard ducted Use this option if chemical vapor re circulation into the work zo
5. gt Labculture Labculture nl SHA EN12469 NSF 49 UL 61010 JIS K3800 SFDA YY 0569 EN 12469 SANS 12469 La D C U It U re RELIANT Labculture Class Il Type A2 Biosafety Cabinet Model LA2 4A_ E Class Il Type A2 and B2 Biological Safety Cabinets The Most Certified Energy Efficient Safe and Ergonomic Biosafety Cabinet in the World ESCO WORLD CLASS WORLDWIDE LABCULTURE CLASS II TYPE A2 LA2 and B2 LB2 BIOSAFETY CABINETS RS 232 Port and Zero Volt RS 232 SERIAL alay contact Relay Contact INTERFAC raa PoR a RS 232 Port to send operational information to Building Management System BMS s Zero Volt Relay Contact to turn ON OFF a exhaust blower and signal the building alarm Airflow Sensor m Monitors real time airflow for safety mAlert the user if airflow is insufficient V ET DIAGNOSTICS ESCO Class Il Type A2 SentineleGOLD MICROPROCESSOR CONTROL SYSTEM Sentinel Gold Microprocessor Controller Displays all safety information on one screen m Centered and angled down for easy reach amp viewing Selectable Quickstart mode for fast operation Single Piece Wall mi Large radius for easy cleaning Side mounted electrical outlets and staggered service fixtures for easy reach Single Piece Work Tray m Recessed to contain spillage m Curved grill to prevent blockage Raised Arm Rest mi Helps prevent grille blocking m Comfortable working posture
6. gt 99 999 for particle size between 0 1 to 0 3 microns per IEST RP CC001 3 PG NSF ANSI 49 62 5 dBA 63 dBA 63 5 dBA 64 dBA 64 5 dBA 5 EN 12469 59 5 dBA 60 dBA 60 5 dBA 61 dBA 61 5 dBA eee Bare gt 230 Lux gt 1400 Lux gt 1070 Lux gt 1230 LUX gt 1230 Lux gt 114 foot candles gt 130 foot candles gt 100 foot candles gt 114 foot candles gt 114 foot candles Electrogalvanized steel with Isocide oven baked epoxy polyester powder coating and Stainless Steel 304 316 is optional Sa 1 5 mm 0 06 16 gauge thick Full Load Amps 230 V A5A 5 5 A 5 7 A 6A 6 5A E a Full Load Amps 115 V 9A 11A 11 5A 12A 13A Heat Load 162 E107 talk 2317 BTU rr 2195 BTU tak 3184 BIU Hr 393 3 BTU H O al Power Co ptio 250W 285W 345W 380W 520W et Weig 243 kg 536 lbs 283 kg 624 lbs S50 kG 772 ps 426 kg 9339 Ibs 580 kg 1279 lbs oping Weic 292 kg 644 Ibs 345 kg 761 Ibs 410 kg 904 Ibs 486 kg 1072 Ibs 640 kg 1411 Ibs oping Dimensio 1200 x950 x 1900 mm 1550 x950 x 1900 mm 1950 x950 x 1900 mm 2150 x 950 x 1800 mm 2720 x 950 x 1900mm a D 47 2 X 374 x 74 8 61 0 x 37 4 74 76 8 x 37 4 x 74 8 84 6 x 37 4 x 74 8 84 6 x 37 4 x 74 8 01011010 A0 e Ma 217 ME O7 Gua 2 80 m 99 cu ft 3 52 MP 124 cuit 3 88 m3 137 cu ft 4 91 m 173 cu ft Depth includes the remove able arm rest and front cover When they are removed depth is 790 mm 31 1 Noise reading in open field condition anechoic c
7. 8 0 1 341 0 53 m s 105 fom Downflow 0 31 m s 60 fom Inflow 376 M A 223 cm 492 m h 292 cfm 608 m h 361 cfm 724 m h 429 cfm 945 m h 560 cfm Downflow 628 m h 363 cfm 822 m h 476 cfm 1016 m h 588 cfm 1210 m h 700 cfm 1580 m h 914 cfm CBV Exhaust Air 1127 m h 658 cfm 1476 m h 862 cfm 1824 m7 n 1065 cfm 2173 Mma 1269 cfm 2835 m h 1656 cfm Min Exhaust Static 400 Pa 1 6 in H O 375 Pa 1 5 in H O 375 Pa 1 5 in H O 400 Pa 1 6 in H 0 475 Pa 1 9 in H O CBV Exhaust Static 575 Pa 2 3 in RLO 550 Fa 2 2 in RLO 550 Pal 2 2 in H O 5 5 Fa 2 3 in FLO 650 Pa 2 6 in H O oe PA er Typica e gt 99 999 for particle size between 0 1 to 0 3 microns 3 PA er Typica e gt 99 99 at 0 3 microns 2 ash Opening 508 mm 20 10 A NSF ANSI 49 5y 58 59 60 61 i EN 12469 54 55 56 S7 58 oresce amp Inte At Zero gt 1250 Lux v gt 1400 Lux gt 1200 Lux gt 1200 Lux gt 1200 Lux Ambie gt 116 foot candles gt 130 foot candles gt 111 foot candles gt 111 foot candles gt 111 foot candles ais Main Body Electro galvanized steel with white oven baked epoxy polyester Isocide antimicrobial powder coated finish Work Zone Stainless steel Type 304 with No 4 finish Full Load Amps 230 V 45A 5 5A 5 7A 6A 6 5A a Full Load Amps 115 V 9A 11A 11 5A 12A 13A Heat Load 1962 BTU
8. Stand Sitting Posture Adjustable 28 30 _ Indicates Size in Feet 4 5 6 Example SPL 4FO for 4 ft Shipped Flat P 0 Leveling Feet Stand Standing Posture Adjustable 34 36 _ Indicates Size in Feet 4 5 6 Example SPL 4G0 for 4 ft Shipped Flat SPL _GO P 0 Caster Wheel Stand Sitting Posture 710 mm 28 Fixed Height _ Indicates Size in Feet 4 5 6 Example SPC 4FO for 4 ft Shipped Flat P 0 Caster Wheel Stand Standing Posture 860 mm 34 Fixed Height _ Indicates Size in Feet 3 4 5 6 Example SPC 4G0 for 4 ft Shipped Flat STL _AO AO Telescoping Feet Stand Manually Adjustable 28 36 by Pins _ Indicates Size in Feet 3 4 5 6 Example STL 4A0 for 4 ft Shipped Flat P A Hydraulic Stand Electrically Adjustable 28 to 36 _ Indicates Size in Feet 4 5 6 Example SPM 4A2 for 4 ft 230 V Shipped assembled Universal Service Fixture Kit Suitable for Air Gas Vac 3 and 4 ft units come standard with 1x 5 and 6 ft units come standard with 2x SPM 4A1 lV bar kit Includes 6 hooks Max Load 6 Kg 13 Ibs Specify model when ordering Field installed DAVALO Air Tight Damper for All Class II A2 Cabinets 9 75 Dia x 9 75H fits inside 10 duct 6 Thimble exhaust transition for A2 cabinets Specify Model when ordering e g ECO LA2 4 DAMPER 10 ABBV 10 Anti Blow Back Flow device automatically shuts preventing back flow in the duct when the exhaust system is off 10 Diamete
9. and Canada 877 479 3726 e Tel 215 441 9661 Fax 215 441 9660 us escoglobal com usa escoglobal com Esco Micro Pte Ltd e 21 Changi South Street 1 Singapore 486 777 Tel 65 6542 0833 Fax 65 6542 6920 mail escoglobal com www escoglobal com Esco Global Offices Beijing China Chengdu China Kuala Lumpur Malaysia Manama Bahrain Guangzhou China Hanoi Vietnam Melaka Malaysia Mumbai India Philadelphia PA USA Salisbury UK Shanghai China Seoul Korea Delhi India Osaka Japan Manila Philippines Mid rand South Africa Jakarta Indonesia Singapore gical Safety Cabinet_LA2 LR2 LB2_combined_brochure_A4_vA_June 2013 Esco can accept no responsibility for possible errors in catalogues brochures and other printed materials Esco reserves the right to alter its products and specifications without notice All trademarks and logotypes in this material are the property of Esco and the respective companies 90101XX_Biolo Esco Micro Pte Ltd PT Esco Bintan Indonesia Cert No 651076 Cert No 651333 E
10. lamp 20 Removable side dress panel for 12 Standard IV bar Retrofit Kit provision plumbing access m Enables he cabinet to be sealed off during decontamination Maximum load for IV bars is 6 kg 13 Ibs 21 Pre filter 13 Service Fixture Retrofit Kit provisions 22 Cabinet power inlet 2 on Each Side 23 Auxiliary power inlet Note Cabinet shown with optional support stand optional air tight damper optional anti blowback valve and optional exhaust blower Exhaust ductwork is not provided by Esco 24 Zero voltage relay contact 25 RS 232 port 14 Electrical outlet Retrofit Kit provision 0 9 meter 3 model one single outlet in Labculture LB2 Class Il Type B2 Biological Safety Cabinets LA2 and LB2 Sentinel Gold Microprocessor Control System LCD simultaneously displays time Diagnostics button to easily Large touchpad Color coded LED green Programmable UV airflow amp sash status inflow and check the cabinet operating contro buttons for fan blue for FL light timer extends a S downflow velocities and status parameters and assist servicing provides good lights and outlets and UV lamp life remarks tactile feedback orange for UV lamp LB2 Display i DIAGNOSTICS SY SentineleGo_Lp MICROPROCESSOR CONTROL SYSTEM AVdd o a se re zio Wlall EF o Wirk SIOIOOdICEA aTe s1elial SPC _FO olo 2 DI elalte P 0 Leveling Feet
11. outlets in workzone 17 Single piece stainless steel back wall and 4 Downflow ULPA filter angled ice fi isi teh l 3 10 Pagg eg SENICE PAUA Provisions 2 0n 12 Stainless steel single piece work tray side walls 5 UV light Retrofit Kit provision each side l l a i 14 Electrical outlet Retrofit Kit a 13 Stainless steel armrest 18 Removable side panel for plumbing 6 IV bar Retrofit Kit provision EEA ese eS igo as 14 Drain valve Retrofit Kit provision ACCESS Optional Exhaust Collar Positions for Thimble Ducting for LA2 and LR2 Models 250 mm g9 a 387 mm 15 2 LA2 3A LR2 3S 358 mm 14 1 LA2 4A LR2 4S 596 mm 23 5 LA2 5A LR2 5S 711 mm 28 0 LA2 6A LR2 6S 1300 mm 51 2 LA2 8A LR2 8S Side View All Sizes Top View All Sizes Labculture _Labculture RELiIANT LA2 Class Il Type A2 LR2 Class Il Type A2 Biological Safety Cabinets For Biohazard and Chemical Hazard LB2 Class Il Type B2 Biosafety Cabinets Cabinet Filtration System Side capture zones Dynamic air barrier inflow and forward directed downflow air converge Ambient air is pulled through the front grille to prevent contamination of the work surface and work product The inflow does not mix with the clean air within the cabinet work zone Ambient air is taken in through a pre filter at the top of the cabinet and passes through the downflo
12. Power Consumption in Watts for Various 4ft A2 LABCULTURE RELIANT CLASS II TYPE A2 BIOSAFETY CABINETS ISSTIDE powder coat n Silver ion impregnated powder coat O Inhibit microbial growth to improve safety A N T 3 o g 2 5 s a o a E 2 o S a 0 4hours 8hours 12hours 16hours 20hours 24 hours Contact Time in Hours Dynamic Chamber m Blower plenum and side walls are surrounded by negative pressure m Prevent contaminants from escaping outside Positive pressure P Negative pressure Single Piece Wall Large radius for easy cleaning Side mounted electrical outlets and staggered service fixtures for easy reach Single Piece Work Tray m Recessed to contain spillage m Curved grill to prevent blockage Raised Arm Rest mi Helps prevent grille blocking m Comfortable working posture Available in 0 9 1 2 1 5 1 8 and 2 4 meter models 3 4 5 6 and 8 Shown with optional telescoping stand Angled Drain Pan Easy to clean A Does not harbor contaminants i NSF 49 UL 61010 Labculture RELiANT LR2 Class Il Type A2 Biological Safety Cabinets FEATURING SIMPLE SWITCHES AND GAUGE Energy Efficient ECM Motor m Powered by latest generation ECM motor that is more efficient than legacy ECM and VFD motors m 70 Energy savings compared to AC motor m Stable airflow despite building voltage fluctuations amp filter loading m Night S
13. aldehyde decontamination protocol All panels leading to potentially contaminated and or hazardous areas shall be color coded red All components with the exception of blower motor and ULPA filters shall be located outside of contaminated air spaces to facilitate servicing without the need to decontaminate the cabinet All exterior surfaces shall be painted with a permanent antimicrobial inhibitor coating to minimize contamination G Control and Alarm System LA2 and LB2 only 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 39 40 41 Not applicable for LR2 All cabinet functions shall be managed by a programmable microprocessor control system capable of software updates via Internet email downloads The microprocessor controller shall be centrally mounted on the main control panel angled down toward the user for easy access The controller shall include soft touch keypad controls and backlit LCD displays to permit operation of the blower motor light UV lamp electrical outlet s and menu The LCD shall be large enough to simultaneously display cabinet model clock inflow downflow sash status airflow status and cautionary message should a deviation from normal operating parameters occur The controller shall be user programmable on site to enable or disable functions such as PIN personal identification number access restriction cabinet start up pro
14. all have a one piece stainless steel 304 side and back wall with gt 4 radius back corners to allow easy surface decontamination Siliconed joints and 90 bends on the back corners are not allowed because they are hard to surface decontaminate and can harbor contaminants The work tray shall be one piece integrated with the front grille removable stainless steel grade 304 with 45 angle on all sides without crevices or joints The cabinet shall have a stainless steel grade 304 one piece drain trough with 45 angle on all sides with smooth polished corners to enable easier surface decontamination No 90 angle is allowed on any side of the drain trough The closed side wall below the normal sash operating height shall be sealed without perforations return air slots or concealed areas which can harbor contaminants The cabinet shall be free of sharp edges nonfunctional protrusions bolts screws or hardware and all metal edges shall be deburred The cabinet exterior top shall be slanted to discourage placement of foreign objects and to maintain proper exhaust airflow E Ergonomics and Convenience 25 26 27 28 29 30 31 32 33 34 The front sash shall be frameless to maximize visibility Sash glass shall be safety glass The sash counterbalance shall be suspended on two high strength cables and for safety the sash shall lock into position in the event one cable becomes detache
15. ar the work surface the downflow splits About Half goes to the front grille and half goes to the rear grille A small portion enters the the side capture zones to prevent dead air corners small blue arrows Aloud The design was optimized to give large 65 49 fom wrt at _ ULPA filtered air performance opeope t that provides operator Dynamic air barrier eE ee and downflow converge Side capture zones 05610 0 35 0 40 0 45 Dov NY if I ov ma 1540 mm 60 6 1540 mm 60 6 970 mm 1270 mm 1570 mm 1870 E mm 1175 mm o 170 mm 6 7 970 mm 1270 mm 1570 mm 1870 mm 2440 mm 175mm 38 2 50 0 61 8 73 6 96 0 69 623 mm 24 5 38 2 50 0 61 8 73 6 96 0 69 _ 1115 mm 1420 mm 1725 mm 2030 mm 2600 mm__ 815 mm 32 1 _ 7 1115 mm 1420 mm 1725 mm 2030 mm 2600 mm 43 9 55 9 67 9 79 9 102 4 352 mm 33 5 43 9 55 9 67 9 79 9 102 4 1 Airflow sensor 7 RS 232 port 0 9 meter 3 model one single 15 Esco Sentinel Gold microprocessor Sahaus t LBA Alter 8 Electrical Electronics panel outlet in workzone 1 2 1 5 1 8 control system 3 Energy efficient ECM Blower 9 Fluorescent lamps and 2 4 meter 4 5 6 amp 8 models 16 Safety glass sliding sash window two single
16. d Magnetic not mechanical proximity sensors shall work in conjunction with the control system to indicate proper sash position for containment Fluorescent lamps shall be mounted behind the control panel module out of the work zone Electronic ballasts shall be used to eliminate flicker extend lamp life and reduce heat output The UV lamp shall operate via an automatic timer with automatic shut off managed by the microprocessor controller to extend the UV lamp life and shall be interlocked with the blower motor and fluorescent lights for safety The cabinet shall be designed with a 10 angled front to optimize user comfort reduce glare and maximize reach into the work area The front grille shall be angled to prevent airflow blockage by accidental placement of objects Penetrations for petcocks and service fittings shall be provided penetrations shall be offset to improve user access The cabinet shall accommodate an optional mounting stand for fixed height or adjustable height configurations The cabinet shall be equipped with arm rest that is raised above the inflow grille to improve comfort and prevent the operator s arms from blocking the inflow grille The arm rest shall be made from one piece stainless steel 304 that can withstand decontaminant agents and UV lamp F Certification Service and Decontamination 35 36 37 38 The cabinet shall be approved for both hydrogen peroxide vapor HPV and form
17. desired minutes or hours Prolongs UV lamp for not turning it ON overnight Certification Biosafety Cabinets Air Quality Filtration Electrical Safety Standards ISO 14644 1 Class 3 Worldwide EN 1822 H14 Europe UL C 61010A 1 USA Compliance NSF ANSI 49 NSE JIS B9920 Class 3 Japan IEST RP CC001 3 USA CSA22 2 No 1010 192 Canada JIS BS5295 Class 3 Japan IEST RP CC007 USA EN 61010 1 Europe US Fed Std 209E Class 1 USA IEST RP CC034 1 USA IEC61010 1 Worldwide The NSF ANSI 49 certified models are LR2 4S1 E LR2 4S2 E LR2 453 E LR2 5S1 E LR2 5S2 E LR2 5S3 E LR2 6S1 E LR2 6S2 E and LR2 65S3 E E l WORLD CLASS WORLDWIDE LA2 and LR2 CLASS II TYPE A2 BIOSAFETY CABINETS ror Bichazard x Ambient air is pulled through front grille to create inflow without going into the work surface Inflow is joined by half of the downflow f f f rr High Inflow to create front air curtain that is fine tuned High Downflow to create a large performance envelope The High Inflow e combined air stream travels through the back Fow pape a air column towards the blower Approximately 1 3 of the air in the common plenum is exhausted through the ULPA filter to the room The remaining 2 3 of the air is passed through the downflow ULPA filter and into the work area as a vertical laminar flow air to create ISO Class 3 work surface and prevents cross contamination gt W 2 D gt gt O Ne
18. etback mode to further reduce power consumption by 60 Power Consumption in Watts for Various 4ft A2 BSC with ECM amp VFD Input Voltage Conventional AC motor motor voltage fluctuation airflow fluctuation Esco LA2 E LR2 E Competitor N Competitor B h 100 Esco ECM motor stable motor voltage stable airflow ULPA Filter mi 10x Filtration efficiency of HEPA filter mi Creates ISO Class 3 work zone instead of industry standard ISO Class 5 gt Labculture RELIANT f 3 Typical Penetration Esco cabinets use ULPA filters per IEST RP CC001 3 instead of HEPA filters in common BSC HEPA filters offer 99 99 typical efficiency at 0 3 micron while ULPA filters provide 99 999 typical efficiency for particle sizes of 0 1 to 0 3 micron 0 15 0 20 0 25 0 30 Particle Size um Rocker Switches and Pressure Gauge m Easy to use switches Displays filter loading status Manually adjustable UV timer ESCO WORLD CLASS WORLDWIDE gt Vil W RUN g I I 4 7 2 Q 5 1s GY 2 0 Labculture RELIANT Class II Type A2 Biological Safety Cabinet N J YNCHES W C Read all safety related instructions before use nE VI N Operate unit continuously for best performance NN Test certify this cabinet at least annually gt J A Designed to Meet NSF49 UL61010 1 Standards ISO 9001 Quality Certified Manufacturing Environment Adjustable UV Timer m Easily adjustable to
19. g turned on at the same time Filter pressure gauge shall be used to continuously monitor the filter plenum pressure Manually adjustable mechanical UV timer shall be used to control the duration of UV lamp activation to prolong the _ 6 0 WORLD CLASS WORLDWIDE 11 2 escoglobal com LIVE SUPPORT ART Equipment Biological Safety Cabinets CO Incubators Compounding Pharmacy Equipment Containment Pharma Products Ductless Fume Hoods Freeze Dryer Lab Animal Research Products Laboratory Fume Hoods Laboratory Ovens and Incubators Laminar Flow Clean Benches PCR Cabinets PCR Thermal Cyclers Powder Weighing Balance Enclosures Ultra low Freezers Labculture The Esco Group of Companies is a global life sciences tools provider with sales in over 100 countries The group is active in lab equipment pharma equipment and medical devices Manufacturing facilities are located in Asia and Europe R amp D is conducted worldwide spanning the US Europe and Asia Sales service and marketing subsidiaries are located in 12 major markets including the US UK Singapore Japan China and India Regional distribution centers are located in the US UK and Singapore Life Science Chemical Research Assisted Reproductive Technology ART Pharmaceutical Equipment General Equipment cco WORLD CLASS WORLDWIDE Esco Technologies Inc e 2940 Turnpike Drive Units 15 16 e Hatboro PA 19040 USA Toll Free USA
20. hall be angled and oriented to the 10 cabinet front angle to maximize downflow uniformity over the work surface and improve the front aperture containment A removable perforated metal diffuser shall be installed below the supply filter to optimize airflow uniformity and to protect the downflow filter from damage C Blower System 13 The cabinet shall have an energy efficient ECM motor that saves 70 energy compared to conventional AC motor 14 The blower motor system shall automatically maintain 15 16 stable airflow despite given building voltage fluctuation and increased filter loading The cabinet shall incorporate Night Setback mode to reduce the blower speed when the cabinet is not being used by the operator while maintaining a degree of containment The blower motor system shall be enclosed within a 17 dynamic chamber shaped steel plenum and integrated with the removable supply and exhaust filters to simplify filter changing The integral damper shall be externally adjustable without the need to decontaminate the cabinet D Cabinet Design Construction Cleaning 18 19 20 21 22 23 24 The cabinet shall be of triple wall design whereby all positive pressure plenums capable of handling contaminated air shall be surrounded by negative pressure No positive pressure areas shall be accessible external to the cabinet The third wall shall conceal utilities The cabinet sh
21. hamber Cabinet only excludes optional stand Class Il Type A2 can be used to handle minute quantities of volatile toxic chemicals and trace amounts of radionucleotides when thimble ducted Use this option if chemical vapor re circulation into the work zone is permitted Power Rating Voltage VAC Frequency Hz Example 230 50 LA2 4A1 115 60 LA2 4A2 230 50 LA2 4A3 ESO WORLD CLASS WORLDWIDE Without Base Stand With Optional Base Stand 711mm 28 Class Il Type B2 Biological Safety Cabinet TECHNICAL SPECIFICATIONS LB2 3B_ E 1115 x 852 x 1610 mm 44 0 x 33 5 x 63 3 LB2 4B _ E 1420 x 852 x 1610 mm DOU SX So oOo Rs Ye gt a 1725 x 852 x 1610 mm 63 0 35 5 x 65 5 LB2 6B_ E 2030 S52 x 1610 mar HOO Bie ay Gis S 2600 352 1610 ram NODAS Op O 1115x852 x23211 mm 44 0 x 33 5 x 91 4 1420 x 852 x 2321 mm 56 0 x33 5 x 914 1725 x 852 x 2321 mm 68 0 X33 5 xX9ic4 2030 S52 x 232 1 mr OO bis Sess 2600 652 232 ram 10271 x ss 55 xo 970 x 623 X 715 MM I2 X 2AB X2 1270 x623 X 715 min 500 x 245 ZN 1570 x 623 x 715 mia 61 37 X 245 X 281 1870 x625 Xx 715 mMm 73 0 XAS X281 DaO X O23 X 7 15 mia G0 X 2A BE X 2B e 045 m S Sort 0 6 m 6 5 S0 0 75 m 8 1 sq ft 0 9 m 9 7 sq ft 12 m 13 samt 203 mm 8 0 203 mm 8 0 203 mm 8 0 203 mm 8 0 203 mm
22. inet serial number shall be provided with the cabinet and maintained in the manufacturers records Test data verifying all performance criteria shall be available upon request to include a inflow velocity through direct inflow measurement method b downflow velocity and uniformity c filter leak scan with aerosol challenge for both filters d electrical safety Filtration System The cabinet shall have one supply downflow filter and one exhaust filter For Class Il A2 Both filters shall be ULPA type per IEST RP CC001 3 and or meet EN1822 H14 requirements For Class II B2 The downflow filter shall be ULPA type per IEST RP CC001 3 and or meet EN1822 H14 requirements The filters shall be constructed with aluminum frame with mini pleat media design without aluminum separators no wood or fiberboard shall be used in the filter assembly For both filters on Class II A2 and downflow filter on Class II B2 the ULPA filter efficiency shall be gt 99 999 at MPPS and between 0 1 to 0 3 microns particle size An integral filter guard shall be affixed to prevent damage to the filter media The exhaust filter shall further be protected by staggered exhaust damper The filters shall be a individually scan tested by the manufacturer b individually scan tested after assembly and c easily accessible for scan testing on site by means of a dedicated upstream sampling port accessible from within the cabinet The supply filter s
23. ing the work zone The downflow combined with the inflow air enters the common air plenum All air in the common plenum is HEPA filtered and exhausted via a dedicated ducting system to the external environment 315 mm 12 4 1115 mm 1420 mm 1725 mm 2030 mm 2600 mm 43 9 55 9 67 9 79 9 102 4 Recommended B2 Cabinet Installation Exhaust Blower at Terminal End Preferably one workzone 1 2 1 5 1 8 and 2 4 meter blower per individual cabinet and Connected to Exhaust collar 2 Exhaust HEPA filter 4 5 6 amp 8 models two single outlets B Blaier mena Pitot Tube Duct Traverse Penetration Drill Penetrations in Ductwork 4 Downflow ULPA filter angled 15 Stainless Steel Armrest With Groove 5 Downflow Sensor 16 Drain valve Retrofit Kit provision 6 Standard UV light Retrofit Kit provision 17 Esco Sentinel Gold microprocessor 7 Single piece stainless steel work tray control system a 8 Pressure Switch Port 18 Safety glass sliding sash window 9 Exhaust Sensor 19 Single piece stainless steel back wall Air Tight Damper Required 10 Electrical Electronic panel and side walls m Enables static pressure to SOS A A e O be adjusted as filter loads to maintain airflow volume Downflow and Inflow Air Located far away from exhaust blower 11 Fluorescent
24. ne is not permitted 115 60 LB2 4B2 230 50 LB2 4B3 Labculture LB2 Class Il Type B2 Biological Safety Cabinets Purchase Specifications LA2 Class II Type A2 LR2 Class II Type A2 LB2 Class II Type B2 Biological Safety Cabinet A General Performance and Certifications 1 ve 10 11 12 The biological safety cabinet shall comply with the following international standards and the manufacturer shall provide a certified copy of containment and performance tests equivalent to or greater than specified in the following independent international standards for Class Il per NSF ANSI 49 USA JIS K3800 Japan SFDA YY 0569 China and EN 12469 Europe The cabinet shall protect a the operator and laboratory environment from particulates generated within the work zone b the product and process within the work zone from airborne contamination from ambient air c and the product and process within the work zone from cross contamination The cabinet shall be tested by Kl Discus test European Standard EN12469 2000 on statistical sampling basis to validate operator personnel protection The retention efficiency for the front aperture shall be not less than 99 999 Microbiological testing for cabinet performance shall also be performed on a statistical sampling basis Each cabinet shall be listed by Underwriters Laboratories UL CUL or CE for electrical safety Original documentation specific to each cab
25. r D BJA Plastic decon bag for formalin decon on all BSC POR Air tight cable port installed on right side wall Holds 1 4 cables Specify When Ordering ECO XXX X OOT R Ergonomic Foot Rest free standing angled surface easily adjustable from 3 to 11 in 1 increment 20 wide Black Rubber Matte P ANa PVC Armrest for Operator Comfort Easy to Clean 28 Long ABBV 10 PO Microscope Viewing Pouch Factory Installed Specify When Ordering Comprehensive Performance Testing At Esco Every Labculture model manufactured by Esco is individually tested documented by serial number and validated with the following test methods m nflow and downflow velocity m PAO aerosol challenge for filter integrity m Airflow pattern visualization m Flectrical safety to IEC61010 17 m Additional KI Discus containment and microbiological testing are performed on statistical sampling basis Labculture Labculture RELiIANT LA2 amp LR2 Class Il Type A2 LB2 Class II Type B2 Biological Safety Cabinets a ee be eo ee ee ee a eee eS Class Il Type A2 Biological Safety Cabinet Labculture Class II A2 Labculture Reliant Class II A2 TECHNICAL SPECIFICATION 2 3A_ E LA2 4A_ E LA2 5A_ E LA2 6A_ E LA2 8A_ E 0 9 meters 3 1 2 meters 4 1 5 meters 5 1 8 meters 6 2 4 meters 8
26. tocol airflow alarm and other microprocessor controlled operations as outlined in the user manual When programmed ON the start up protocol shall perform an automatic pre purge and post purge cycle to ensure proper cabinet operation The controller shall include a blower motor hours meter to display aggregate motor running time to assist in predictive maintenance Audible and visual alarms shall be provided for unsafe conditions such as improper airflow or sash Airflow shall be monitored by a temperature compensating thermistor based true air velocity sensor mounted in the cabinet The airflow display and alarm system shall be individually calibrated before shipment Diagnostics button should be available on the control panel to easily check the cabinet operating parameters and assist servicing The cabinet shall have field calibration mode that simplifies on site calibration mode A selectable Quickstart mode should be available to automatically turn the blower and lights on off by moving the sash window to correct position The BSC shall have RS 232 data output port for remote monitoring of cabinet operating parameters TCP IP converter shall be available as an option to connect RS 232 to network for remote monitoring Control and Alarm System LR2 only Not applicable for LA2 and LB2 The cabinet shall be controlled by simple rocker switches The switch shall prevent the flourescent lamp and UV lamp from bein
27. w ULPA filter entering the work zone as laminar flow The uniform non turbulent air stream protects against cross contamination within and throughout the work area Near the work surface the downflow air stream splits with a portion moving toward the front air grille and the remainder moving to the rear air grille A small portion of the ULPA filtered LALO i 2 p S Model LB2 Biological Safety Cabinet Technical Specifications 295 mm 11 6 LB2 3 406 mm 15 9 LB2 4 643 mm 25 3 LB2 5 820 mm 32 2 LB2 6 1300 mm 51 2 LB2 8 251 mm 9 8 n ER RA Sa 1610 mm 63 3 1540 mm 60 6 B ekismi a N 970 mm 1270 mm 1570 mm 1870 mm 2440 mm ti 180 mm 7 1 38 2 50 0 61 8 73 6 96 0 A combination of inflow and downflow air streams forms an air barrier that prevents contaminated room air from entering the work zone and prevents work surface emissions from escap