Home

USER MANUAL

image

Contents

1. LANGUAGE UNLOCK ASPECT ACCEPT RATIO CONTINUE HANG UP CONTROL DISPLAY 1 DISPLAY 2 DISPLAY 3 DISPLAY 4 PROJECTOR Cat No 2808 000035 Page 2 10 RC 54DL Front Panel Button Caps and Labels MUSIC fr PROJECTOR PROJECTOR a9 gt Il a Alb v DK Cat No 2808 000035 Page 3 Figure 6 Sample Button Label Sheet RC 54DL Front Panel Button Caps and Labels 7 1 Installing the Front Panel Button Caps Labels To install the button caps and labels 1 Remove the required labels from the supplied button label sheet 2 Hold the button cap so that it is oriented as shown in Figure 7 with the wings on the left and right sides Figure 7 Button Cap Orientation 3 Insert the label inside the cap Figure 8 Button Cap Orientation with Label Note that the button cap for the top left most button on the front panel should be oriented with the wings at the top and lower sides as shown below without with label and then placed over the top left most button as illustrated in Figure 9 4 Retaining the orientation place the button cap over the buttons of the RC 54DL AUS Figure 9 Placing the Button Cap RC 54DL Front Panel Button Caps and Labels Repeat for all caps all ho
2. GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Video Products Congratulations on purchasing your Kramer RC 54DL KNET Auxiliary Control Panel which is designed to let you remotely control an A V system with ease ina multimedia classroom or conference room Each package includes the following items e The RC 54DL KNET Auxiliary Control Panel e 3 Gang US Installation mud ring e Power supply e This user manual 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables Go to http www kramerelectronics com to check for up to date user manuals application programs and to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into
3. Master Room controller for example the Kramer RC 74DL Master Room Controller e The auxiliary panel can be programmed only via the Master Room controller For instructions on using the software see the K Config Software Guide available from our Web site Once configured use the front panel buttons as a remote controller for the connected master room controllers RC 54DL O RC 74DL Feno KNET 1 A 12V PINOUT Black GND White B Green A Red 12V Law Figure 5 RC 54DL to RC 74DL Pinout Connection e RC 54DL Operating the RC 54DL 7 Front Panel Button Caps and Labels The RC 54DL is supplied with a button label sheet and 12 clear button caps to house the labels Figure 6 illustrates a sample button label sheet Ty KRAMER sw ELECTRONICS cD MEDIA pLaver DIRECT MATRIX MEDIA RECEIVER SCALER SET TOP SWITCHER SOURCE SOURCE SOURCE SOURCE SOURCE 1 2 3 4 S VIDEO EE VIDEO 1 VIDEO2 VIDEO3 VIDEO4 LIGHTS AuDIO1 AUDIO 2 AUDIO3 AUDIO 4 LIGHTS Mpa 1 LIGHTS LIGHTS LIGHTS 4 aie 2 2 ii 3 OFF ON OFF ON OFF LIGHTS LIGHTS 3 ON POWER POWER STANDBY I baba STANDBY ON OFF Cat No 2808 000035 RC 54DL Front Panel Button Caps and Labels EE DISPLAY DISPLAY CYCLE VOLUME VOLUME ON OFF SOURCES UP DOWN
4. necessary to satisfy a proper claim under this limited warranty Elect to repair or facilitate the repair of any defective parts within a reasonable period of time free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete 2 Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product 3 Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty What Kramer Electronics will not do Under This Limited Warranty If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any
5. KRAMER ELECTRONICS LTD USER MANUAL MODEL RC 54DL KNET Auxiliary Control Panel P N 2900 3001 30 Rev 1 Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 3 Overview 3 1 The RC 54DL KNET Auxiliary Control Panel Front Side 3 2 The RC 54DL KNET Auxiliary Control Panel Rear Side 4 Connecting the RC 54DL KNET Auxiliary Control Panel 5 Grounding the RC 54DL 6 Operating the RC 54DL 7 Front Panel Button Caps and Labels 7 1 Installing the Front Panel Button Caps Labels 8 Technical Specifications Figures Figure 1 RC 54DL Front Panel Figure 2 RC 54DL Rear Panel Figure 3 Connecting the RC 54DL Figure 4 Grounding Connection Components Figure 5 RC 54DL to RC 74DL Pinout Connection Figure 6 Sample Button Label Sheet Figure 7 Button Cap Orientation Figure 8 Button Cap Orientation with Label Figure 9 Placing the Button Cap NOON DO AKRWNDND oO A ee oe NNN AONDOOAHA Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront video audio presentation and broadcasting professionals on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers
6. OGRAM USB Connect to a computer for firmware upgrade or setting the Connector K NET ID number Power Supply 2 pin Connect to power supply when power is not supplied over Terminal Block Connector the K NET Connect GND to GND 12V to 12V a K NET TERM Switch Slide to the left in the direction of the arrow for K NET termination slide to the right up to leave bus unterminated The last physical device on a K NET bus must be terminated 5 K NET1 Connector Connect the GND pin to the Ground connection pin B and pin A are for RS 485 and the 12V pin is for powering the unit The ground connection is sometimes connected to the shield of the RS 485 cable K NET2 Connector Connect the GND pin to the Ground connection pin B and pin A are for RS 485 and the 12V pin is for powering the unit The ground connection is sometimes connected to the shield of the RS 485 cable 7 Ring Tongue Terminal Connect to grounding wire optional see Section 5 Grounding Screw RC 54DL Overview Connecting the RC 54DL KNET Auxiliary Control Panel Always switch off the power to each device before connecting it to your Transmitter and Receiver pair After connecting your Transmitter and Receiver pair connect their power and then switch on the power to each device To connect the RC 54DL as shown in the example in Figure 3 do the following 1 Connect the K NET ports to any RC devices with K NET for example the
7. OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPICABLE LAW IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A CONSUMER PRODUCT UNDER THE MAGNUSON MOSS WARRANTY ACT 15 U S C A 2301 ET SEQ OR OTHER APPICABLE LAW THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU AND ALL IMPLIED WARRANTIES ON THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE SHALL AP
8. PLY AS PROVIDED UNDER APPLICABLE LAW Other Conditions This limited warranty gives you specific legal rights and you may have other rights which vary from country to country or state to state This limited warranty is void if i the label bearing the serial number of this product has been removed or defaced ii the product is not distributed by Kramer Electronics or iii this product is not purchased from an authorized Kramer Electronics reseller If you are unsure whether a reseller is an authorized Kramer Electronics reseller please visit our Web site at www kramerelectronics com or contact a Kramer Electronics office from the list at the end of this document Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form Kramer Electronics thanks you for purchasing a Kramer Electronics product We hope it will give you years of satisfaction For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com KRAMER E mail info kramerel com SAFETY WARNING Disconnect the unit from the power supply before opening and servicing 130 P N 2900 300 Rev 1
9. RC 63DL and SL 12 2 Connect the 12V DC power adapter to the RC 54DL power socket and to the mains electricity not shown in Figure 3 Alternatively the RC 54DL can receive power over the K NET port via the connected master room controller 13N To RC 74DL To SL 12 Figure 3 Connecting the RC 54DL RC 54DL Connecting the RC 54DL KNET Auxiliary Control Panel Grounding the RC 54DL The grounding screw is used to earth the chassis of the unit to the building ground preventing static electricity from impacting the performance of the unit Figure 4 defines the grounding screw components Component Description 1 M3X6 screw 2 1 8 Toothed Lock Washer 3 M3 Ring Tongue Terminal Figure 4 Grounding Connection Components To ground the RC 54DL 1 Connect the Ring Tongue terminal to the building grounding point wire it is recommended to use a green yellow AWG 18 0 82mm wire crimped with a proper hand tool 2 Insert the M3x6 screw through the toothed lock washers and the tongue terminal in the order shown above 3 Insert the M3x6 screw with the two toothed lock washers and ring tongue terminal into the grounding screw hole and tighten the screw 6 Operating the RC 54DL Since the auxiliary panel is used as a remote controller for Master Room Controllers via the proprietary communication channel K NET as illustrated in Figure 5 e It requires a K NET connection to a
10. ble Button Function is programmed by the K Config Configuration Switches software 2 LCD Label Displays up to 8 characters at once set by the K Config configuration software 3 4 Configurable Button Function is programmed by the K Config Configuration Switches software LCD Label Displays up to 8 characters at once set by the K Config configuration software 5 2 Configurable Button Function is programmed by the K Config Configuration Switches software LCD Label Displays up to 8 characters at once set by the K Config configuration software 7 Rotary Dial up down LED Indicates the level set by the rotary dial indicator VOLUME Rotary Dial Function is programmed by the K Config Configuration software RC 54DL Overview 3 2 The RC 54DL KNET Auxiliary Control Panel Rear Side 1 2 a I E 3 m ed Pal Je ee 5 MAC O00 1D 56 X1 YY ZZ Teno ye Sa Je Figure 2 RC 54DL Rear Panel Feature Function RESET TO DEFAULT Disconnect the power and then connect it while pressing Button the RESET TO DEFAULT button using a small screwdriver The unit will power up and load its memory with the factory default KNET ID auxiliary setting ID 2 This operation should be carried out by authorized Kramer technical personnel or by a qualified system integrator and requires removal of the device from the wall by unscrewing the four wall mount screws PR
11. programming required for a specific installation of this product How to Obtain a Remedy under this Limited Warranty To obtain a remedy under this limited warranty you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you For a list of authorized Kramer Electronics resellers and or Kramer Electronics authorized service providers please visit our web site at www kramerelectronics com or contact the Kramer Electronics office nearest you In order to pursue any remedy under this limited warranty you must possess an original dated receipt as proof of purchase from an authorized Kramer Electronics reseller If this product is returned under this limited warranty a return authorization number obtained from Kramer Electronics will be required You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product If itis decided that this product should be returned directly to Kramer Electronics this product should be properly packed preferably in the original carton for shipping Cartons not bearing a return authorization number will be refused Limitation on Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL
12. rizontally oriented except for the top left button Remove the protective foils from both sides of the Perspex acrylic glass windows Place the faceplate on the RC 54DL so that the four screw mounting holes are aligned Insert the four mounting screws and tighten with a screwdriver Install the volume control knob 8 Technical Specifications PORTS 2 K NET on terminal block connectors 1 USB for programming POWER SOURCE 12V DC 420mA OPERATING 0 to 55 C 32 to 131 F TEMPERATURE STORAGE 45 to 72 C 49 to 162 F TEMPERATURE HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 16 2cm x 2 6cm x 11 4 6 4 x 1 0 x 4 5 W D H WEIGHT 0 6kg 1 4Ibs approx ACCESSORIES Power supply Specifications are subject to change without notice Go to our Web site at http www kramerelectronics com to access the list of resolutions RC 54DL Technical Specifications LIMITED WARRANTY The warranty obligations of Kramer Electronics for this product are limited to the terms set forth below Whatis Covered This limited warranty covers defects in materials and workmanship in this product What is Not Covered This limited warranty does not cover any damage deterioration or malfunction resulting from any alteration modification improper or unreasonable use or maintenance misuse abuse accident neglect exposure to excess moisture fire improper packing and shipping s
13. tight coils e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer RC 54DL away from moisture excessive sunlight and dust Caution No operator serviceable parts inside the unit Warning Use only the Kramer Electronics input power wall adapter that is provided with the unit Warning Disconnect the power and unplug the unit from the wall before installing K NET is a proprietary Kramer protocol for interconnecting Kramer units Overview The RC 54DL is a 3 gang US auxiliary room controller that acts as an all in one extended remote control panel for remotely controlling room controllers for example the Kramer RC 74DL in classrooms boardrooms or auditoriums The RC 54DL features e 12 configurable RGB backlit front panel buttons in three groups e 1 configurable rotary up down controller with direction indicator LEDs e Two K NET control channels that connect compatible user interfaces and supply power and control data over a single cable e Flexible control via K NET k Config is available from Kramer Electronics on our Web site at http www kramerelectronics com support soft k confi 3 1 The RC 54DL KNET Auxiliary Control Panel Front Side This section defines the RC 54DL VOLUME KRAMER RC 54DL Figure 1 RC 54DL Front Panel Feature Function 1 6 Configura
14. uch claims must be presented to the carrier lightning power surges or other acts of nature This limited warranty does not cover any damage deterioration or malfunction resulting from the installation or removal of this product from any installation any unauthorized tampering with this product any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs or any other cause which does not relate directly to a defect in materials and or workmanship of this product This limited warranty does not cover cartons equipment enclosures cables or accessories used in conjunction with this product Without limiting any other exclusion herein Kramer Electronics does not warrant that the product covered hereby including without limitation the technology and or integrated circuit s included in the product will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used How Long Does this Coverage Last Seven years as of this printing please check our Web site for the most current and accurate warranty information Whois Covered Only the original purchaser of this product is covered under this limited warranty This limited warranty is not transferable to subsequent purchasers or owners of this product What Kramer Electronics will do Kramer Electronics will at its sole option provide one of the following three remedies to whatever extent it shall deem

Download Pdf Manuals

image

Related Search

Related Contents

StarTech.com 12in Micro SATA to SATA with SATA Power Adapter Cable  SERVICE MANUAL  User Manual Real Time Octave Band Analyzer Model 407790  iSi North America AMV8 User's Manual  PRIVATE SYSTEM DESKⅡ(小規模ITシステム用)  XProtect Express 2013 Specification Sheet  BODTrak™ II  • OWNER'S MANUAL • MANUEL D'INSTALLATION  Xerox Phaser 4510_DX    

Copyright © All rights reserved.
Failed to retrieve file