1. Connect The first time you connect power it has not yet recognized any terminals as SL12 MP12 or C6 The A8 has two BUS lines A and B When you receive a new A8 both lines will always be protected with shunt plugs In last terminal in the configuration you must insert a shunt plug in BUS 2 use spare one from A8 Inserting BUS line into A8 can be a bit tricky but Ones in it will stay there Then connect to BUS 1 on the first terminal in your configuration Note max 10 terminals per line A and B in total 20 per system Place battery as show here 11 24 05 2011 D SensorLine Retail Security Solutions 7 Notes 8 Contact Danish Office Swedish Office Norwegian Office SensorLine ApS SensorLine AB SensorLine AS Gengehusvej 252 H nekullavagen 11 Fridtjof Nansens Vei 66A DK 2950 Vedb k SE 435 44 M lnlycke NO 1472 Fjellhamar Denmark Sweden Norway T 45 4576 4848 T 46 31 3384848 T 47 2107 5080 F 45 4576 4849 F 46 31 3384845 F 47 9476 3810 M info sensorline dk M info sensorline se M info sensorline no www sensorline dk www sensorline se www sensorline no 12 24 05 2011
2. The display will show the letter d for done MC has now been programmed To program User Cards UC present MC and the letter P for program will show Now present first UC and the letter d for done will show in the display To program more UC follow above routine Note a max of 30 UC Now you are ready to set up the BOSSystem 5 1 2 Delete all User Cards 1 Present MC for approx 10 seconds You will get a fast running beeps keep presenting MC until the display shows the letter d for done All UC has now been deleted from the system To re program UC start from point 3 above 1 D SensorLine Di SensorLine BR Km e WI Rete Security Sidun Lu Reta Security Schutszenm ae P d u p R d d P R m i 4 i 4 4 4 i pE ie 4 iw www sensorline eu D www sensorline eu GG Sweden 46 31 338 4848 I j Sweden 40 31 334 aeaa E 8 Denmark eas 4576 pu E i Denmark 45 4876 4845 W I Norway 47 2107 S080 S Norway 47 2107 5080 5 ion SE 8 4 o i gl D ae ae LZ oe ee j WE allt Mastercard User card p ja km M d D wg a E 24 05 2011 6 Handling of EuroAlarm A8 6 1 Re set button 6 2 Protection of power D SensorLine Retail Security Solutions Press down the re set button and you will get a running beep The system is now back to factory parameters All MC and UC are deleted Remove power and back up
3. battery wait up to 30 sec before re connecting power and you can start to program new MC and UC Adjust volume for alarm The jumper on the top of the board has three pins two positions It is needed that there is always a jumper in place The jumper position closest to the edge means that incoming power will be secured That is if you shut down power at night or remove power from the system then the A8 will give alarm un till back up battery disconnect automatically after approx 2 min When the jumper is placed more to the center incoming power is no longer secured That means If you shut down power no alarm will sound Only the BUS line is protected for a few minutes until back up battery disconnect automatically 10 24 05 2011 6 3 Mounting AS D SensorLine Retail Security Solutions A8 back side There are two ways to mount the A8 Either cables coming out the back or the bottom Either way screw the back side to the wall display when first removing the screw in the bottom of the enclosure Cables If no cables to be seen and therefore coming out from the back make sure to put cables through the back lid before mounting on display If you wish the cables to come out the bottom you simple remove brake the bottom clip The BUS cable can be inserted near the enclosure so coming out nicely along the power cable For drilling holes in display use a 7mm drill for BUS cable and 11mm for power cable
4. D SensorLine Retail Security Solutions BOSSystem Bus Operating Sensor System Intelligent Line Security System Installation amp User Manual 24 05 2011 E SensorLine Retail Security Solutions Index 1 System description Page 3 2 Connection allocation Page 3 4 3 Security information Page 5 4 Installation 4 1 EuroAlarm A8 SL12 electronic devices Page 5 4 2 EuroAlarm A8 MP12 live devices as mobile MP3 GPS Page 6 4 3 EuroAlarm A8 C6 live devices as cameras DSLR Page 7 4 4 EuroAlarm A8 SL12 w power for showcases Page 8 5 Programming 5 1 Programming Master and User Cards Page 9 5 1 2 Delete all User Cards Page 9 6 Handling of EuroAlarm AS 6 1 Re set button Page 10 6 2 Protection of power Page 10 6 3 Mounting AS Page 11 7 Notes Page 12 8 Contact Page 12 24 05 2011 D SensorLine Retail Security Solutions 1 System description This intelligent BOSSystem both secures and charges your phones The BOSSystem is so easy to understand 1 2 3 steps and you have a working system Hour long service calls to find the root of the problems are history The new BOSSystem you can control with one card This is all you need to service it the system will do the rest The microprocessor in the BOSSystem measures for any changes to the system 2000 times per second and charges all devices at the same time A controlled delay prevents false alarms and instability Therefore no shunt plugs are
5. needed This is a huge difference from our previous systems 2 Connection allocation EuroAlarm A8 central unit 100mm 70mm 30 5mm BUS Bus connection for system terminals like MP12 SL12 and C6 24 05 2011 D SensorLine Retail Security Solutions EuroAlarm MP12 charging securing unit for live devices as mobile phones MP3 players GPS etc BUS 1 2 BUS 2 Power I O 1 12 SensorLine Bus connection for system terminals MP12 SL12 C6 Connect additional terminal or shunt plug if last terminal Power Supply for MP12 5V External Siren Flash Light CCTV Sensor ports EuroAlarm SL12 securing unit for various electronic devices BUS 1 2 BUS 2 Power I O 1 12 SensorLine Ariel Lei v r BOSSystem EuroAlarm A A Ses li ne eu Bus connection for system terminals SL12 MP12 C6 Connect additional terminal or shunt plug if last terminal Power Supply for Lock Splitter securing showcases 12V External Siren Flash Light CCTV Sensor ports EuroAlarm C6 charging securing unit for live cameras camcorders and DSLR BUS 1 2 BUS 2 Power I O 1 6 SensorLine Bus connection for system terminals C6 MP12 SL12 Connect additional terminal or shunt plug if last terminal Power Supply for C6 12V External Siren Flash Light CCTV Sensor ports 24 05 2011 SensorLine Retail Security Solutions 3 Security information Please follow the securit
6. y measure as described below 1 Always use the correct port connections Always use SensorLine or SensorLine compatible products 3 Do not use the BOSSystem or parts of it for other things as the ones subscribed in this manual 4 Installation 4 1 Installation of EuroAlarm A8 with SL12 configuration for 12 24 or more secured electronic devices Object 1 6 Object 13 18 Object 7 12 Object 19 24 Shunt plug e ri GS we 24 05 2011 D SensorLine Retail Security Solutions 4 2 Installation of EuroAlarm A8 with MP12 configuration for 12 24 or more secured live devices charged Object 1 6 Object 13 18 24 05 2011 D SensorLine Retail Security Solutions 4 3 Installation of EuroAlarm A8 with C6 configuration for 6 12 or more secured live cameras charged P P Object 1 6 Object 7 12 a ws 24 05 2011 D SensorLine Retail Security Solutions 4 4 Installation of EuroAlarm A8 with SL12 configuration for 12 24 or more showcases Lock 13 18 Lock 7 12 Lock 19 24 Shunt plug E y de CH 24 05 2011 D SensorLine Retail Security Solutions 5 Programming 5 1 Programming Master and User Cards When the unit is new there are no Master nor User Cards programmed in the system l 2 P Connect power to A8 The number 8 will show in the display and running beep will sound Present Master Card MC in front of the antenna field display