Home

to the User Manual

image

Contents

1. connected directly to the battery Cable safety B1 12V 24V Battery i OP TN NL a Attention Do not connect additional cables here Consumers chargers minus distribution or vehicle ground are not allowed to be connected here START Battery Fuse 3A Measuring Shunt Attention Observe direction of arrow Car body Ground amp o MINUS Consumer Distribution Consumer Distribution soma MINUS Charger Solar Regulator Solar Regulator ger g Storage Battery Battery Controller Controller etc Except of the measuring shunt no further connection should exist at the negative pole of the battery A or at the negative pole of the entire battery system This concerns consumers vehicle ground as well as chargers Further connections have to be made either to the car body ground or in case of insulated vehicle bodies to the minus distribution See connection plan Initial Start up The battery computer is ready for operation as soon as all electric connections are made at the measuring shunt and the connection to the display unit had been made Basic Setting e The existing system voltage 12 V or 24 V must be set e The used battery type gel AGM liquid acid must be set e The capacity of the board battery must be set The capacity is indicated in Ah and it is imprinted on the battery If several Ah values can be found use the value Ah 2
2. supply Adjustment of the Battery Type Adjust the battery type 1 4 of the board battery 1 Lead Acid Liquid acid Lead Battery 2 Gel 3 AGM 4 LiPoFe The battery type is shown in the left lower margin of the display Adjustment of the Nominal Capacity The nominal capacity of the battery see start up can be adjusted in three steps First the capacity in steps of 100 is adjusted after that in steps of 10 and after that in steps of 1 Ah After adjustment of the nominal capacity the battery computer sets automatically a residual capacity of 75 A full charging cycle is required see start up to be continued Nominal Capacity Ones Column Terminal Switching on Threshold Capacity Terminal Switching off Threshold Capacity Memory lowest voltage Memory highest voltage Memory lowest capacity Memory highest capacity hours ago the i battery got fully charged Background Illumination continuation Adjustment of the Terminal Switching on Threshold Here the switching threshold for the automatic activation of the terminal can be adjusted The switching threshold can be set to 101 Thus an automatic activation will never be reached Adjustment of the Terminal Switching off Threshold The same is true as for the switching on threshold An automatic disconnection can be prevented by setting this value to 0 The memory for the lowest and highest voltage and capaci
3. Friedrich Diehm Str 10 36341 LAUTERBACH GERMANY Phone 49 0 6641 91173 0 Fax 49 0 6641 91173 20 E mail info votronic de Internet www votronic de
4. specific segments 49 x 28 mm white LED 80 x 85 x 24 approx 66 x 72 approx 55 g 100 A 200 A 400 A 100 A 200 A 400 A 120 A 240 A 480 A 150 A 300 A 600 A 200 A 400 A 800 A 250 A 500 A 1000 A 300 A 600 A 1200 A 450 A 900 A 1800 A 1000 A 2000 A 4000 A 135 x 30 x 41 160 g 180 g 200 g max 95 RH no condensation zilk Notes 12 Delivery Scope Available Accessories 1 ea Battery Computer Display Control Cable Extension 5 m Length Order No 2005 1 ea Measuring Shunt 100 A 200 A or 400 A Casing Order No 1214 1 ea Ground Strap 1 ea Control Cable Length 5 m 4 ea Fastening Screws I ea Operating Manual 1 ea Drilling Jig Disposal of the The product conforms to RoHS xx product in the Ro H S Thus it complies with the directives for Quality Management normal household 2002 95 EC Reduction of Hazardous Substances in System Waste is not Electrical and Electronic Equipment DIN EN ISO 9001 allowed Declaration of Conformity C According to the stipulations of the regulations 2006 95 EG 2004 108 EG 95 54 EG this product corresponds to the following standards or standardized documents EN55014 EN55022 B DIN14685 DIN40839 1 EN61000 4 2 EN61000 4 3 EN 61000 4 4 Subject to misprints errors and technical modification without notice All rights reserved particularly the right of reproduction Copyright VOTRONIC 04 13 Made in Germany by VOTRONIC Electronic Systeme GmbH amp Co KG Johann
5. 0 h If several batteries have been combined to a battery system add the Ah values Total capacity for 2 batteries at 110 Ah is 220 Ah This value 220 Ah must be set see page 7 recognize 100 full charging factory adjustment 75 required for starting After the basic setting the battery must be charged using a suitable charger in case of mobile homes using the existing board charger for a duration of 24 h This is absolutely required so that the battery computer is able to i If the computer loses its voltage supply battery disconnected etc the capacity must be set again and the battery must be recharged completely After adjustment of the battery capacity and after loss of the supply voltage the capacity which can be withdrawn will be set automatically to 75 factory adjustment After that the battery must implicitly be charged for at least 24 hours with a suitable automatic charger to ensure correct display of the capacity Only when the battery had been fully charged the system adjusts itself to its battery and the display will show 100 or the residual capacity of the battery in Ah The initial settings and the full charging of the battery are absolutely required to ensure proper capacity indication and it must be repeated whenever the unit or the battery had been disconnected Operation LCD Battery Computer S a wr wy VOTRONIC vv Button 1 Next page of the battery computer display Z a ee manual
6. VOTRONIC Installation and Operating Manual LCD Battery Computer 100 S with Measuring Shunt 100A No 1262 LCD Battery Computer 200 S with Measuring Shunt 200 A No 1265 LCD Battery Computer 400 S with Measuring Shunt 400A No 1268 Precise and complete battery control for all commercial types of lead storage batteries in vehicles and boats The VOTRONIC LCD Battery Computer S calculates the exact charging state of the battery and displays the charging state like a fuel gauge for the battery In contrast to simple ampere hour meters the residual capacity will be determined in ampere hours Ah or the residual charge in by means of programmed characteristic diagrams of batteries and will be displayed as charging state Furthermore the unit is equipped with a programmable terminal for connection or disconnection of consumers or further energy supply units depending on the charging state of the battery Apart from this the LCD Battery Computer S provides the display of the battery voltage V of a second battery starter battery Due to its various display functions it allows a centralized supervision of the consumers as well as of the most important processes at the battery at any time So it allows quick reactions to undesirable developments or to take corrective measures in good time The precision measuring shunt for detection of the battery current being provided with the unit is extraordinary robust very exactly and shows extreme ov
7. disconnection of the terminal 3s On Charge a OFF s J hr Button 2 Previous page of the display manual activation of the terminal 3s Ah Battery Power OFF 3s ON 3s Set 3s Button 3 Display on off Set 3s Set s ress ern ON 3s Start Bord Made in Germany A Terminal CoN or OFF on amA E q _ Indication Unit Ah Indication refers Bar Graph 0 100 to board battery Activation Deactivation The LCD Battery Computer S requires continuous current supply to ensure continuous capacity measurement The unit is optimized for extremely current saving operation and offers three operation modes Stand by During stand by mode the display is empty If the terminal is activated ON will be displayed and if it is switched off OFF will be displayed Display with and without illumination As soon as the LCD Battery Computer S is operated the display illumination will be switched on and will remain activated for 3 minutes If there is no operation during this time the illumination will be switched off automatically The display shows the same data as before when the illumination was active The display illumination is reactivated by pressing any button The proper function of the button will be effected by pressing the button a second time Display Contrast Reading Angle The LCD Battery Computer S is equipped with a high co
8. erload capacity also refer to Technical Data The dimensions of the unit are perfectly adapted to the VOTRONIC modular system The VOTRONIC modular system includes the tank display units fresh and sewage water as well as feces the LCD series solar display voltmeter ammeter and thermometer as well as the switch and fuse panels Please read the mounting instructions and operating manual including the safety regulations completely prior to starting connection and start up Installation and Connection Display Unit The small mounting depth approx 27 mm of the electronic system allows flush mounting into furniture boards to ensure that an optimum installation place can always be chosen The clear opening of the cutout is min 71 x 66 mm to ensure safe alignment of the front panel Please use the delivered drilling jig which has been designed to consider combination with further display panels If possible the rear cutout opening should be covered with electrically nonconducting material to ensure efficient protection of the electronic system and full utilization of the storage space which might be located behind The delivered control cable of 5 m length is used to connect the display unit to the delivered current measuring shunt The connection is executed ready to be plugged in and the cable should be laid according to the safety instructions The length of the control cable is 5 m If this length is not sufficient for connection o
9. ery room gases Terminals Connection B1 Board Battery For the voltage measurement of the board battery a direct connection from this terminal to the positive pole of the board battery must be made The cable is to be protected by means of a 3 A fuse directly at the battery The connection cross section should be 0 75 mm at least This connection also provides current to the LCD Battery Computer S and to the terminal Connection B2 Starter Battery For the voltage measurement of the starter battery a direct connection from this terminal to the positive pole of the starter battery must be made The connection cable is to be protected by means of a 3 A fuse directly at the battery The connection cross section should be 0 75 mm at least Connection Out Terminal A freely programmable terminal is at disposal Depending on the setting this terminal can be used as timer or for capacity disconnection In active condition ON the battery voltage 12 V or 24 V is here at disposal and it is protected against overload by means of a self resetting fuse 0 5 A The terminal can be reinforced by an interposed changeover relay Connection Plan ee PLUS Consumer VERONI Distribution fo On Charger 36 7 Solar Regulator Ab Storage Battery Controller a m ai Control Cable etc si Length 5 m Battery Power 280 C Mage in Germany Oj red 0 75 1 5 mm Fuse 3A Observe If possible the fuse should be
10. f the connection unit the cable extension of 5 m length order No 2005 being available as accessory can be used The total cable length is then 10 m Measuring Shunt Any battery current should flow over the measuring shunt Therefore it is to be installed directly near the battery batteries Observe that all consumers and charging devices for the battery must be led over the shunt in order to allow a registration of any battery activity Battery systems are to be connected according to the plan Battery Systems 24 V 90 Ah 24 V 180 Ah at the negative pole of the entire battery system This concerns consumers vehicle ground as well as chargers Further connections have to be made either to the car body ground or in case of insulated vehicle bodies to the minus distribution See connection plan Except of the measuring shunt no further connection should exist at the negative pole of the battery or Ground straps at the connecting screws M8 of the measuring shunt are to be screwed in such a way that one connection is connected to the negative pole of the battery and the other one with the car body The arrows on the base of the measuring shunt should point to the direction of the battery see connection plan The connections at the measuring shunt should always be tightened firmly to avoid any transition resistance Permanent high load of 200 A or 400 A might result in heating of the measuring shunt Ventilate the batt
11. gh load for a 70 Ah battery Correspondingly the large storage battery provides almost its full capacity but the small 70 Ah battery only 42 Ah or 60 of the indicated nominal capacity at best The result is a correct indication of the available capacity in the battery residual capacity charging state such as it is known from a fuel gauge It is a matter of course that also the self discharge of the battery in case of long downtimes will be considered During charging of the battery the full charging state will be recognized automatically and it will be corrected if required Depending on the quality of the used charger the charged capacity may be between 80 and 100 The capacity of the board battery will be displayed in ampere hours Ah and as percentage of the nominal capacity The bar graph at the left margin of the display represents the capacity in steps of 10 b System Voltage 12V 24V Battery Typ l LeadAcid 2 Gel 3 AGM 4 LiFePo4 Nominal Capacity Hundreds Column Nominal Capacity Tens Column Press more than 3 seconds Settings Battery Computer until Set is flashing The menu for settings is called by pressing and holding button 3 for more than 3 seconds The buttons 1 and 2 are used to set the values In the menu the button 3 is used to save the setting and to jump to the next menu item Adjustment of the System Voltage Adjust the system voltage 12 V or 24 V of the board mains
12. mage Never use solvents or aggressive household cleaners for cleaning of the display The warranty period is 24 months from the purchase date against presentation of the sales slip or invoice The warranty will be void in case of any inappropriate utilisation of the unit if it is used beyond the technical specification in case of improper operation or external intervention We do not assume any liability for any damage resulting hereof The liability exclusion is extended to any service being executed by third which has not been ordered by us in writing Service is to be effected exclusively by VOTRONIC D 36341 Lauterbach Technical Data System Nominal Voltage Operating Voltage Range Current Consumption Battery Types Lead Battery Types LiPoFe Display Unit LCD Display Technology Representation Surface Illumination Dimensions mm Assembly Dimensions Opening Electronic System mm Weight Precision Measuring Shunt Max Admissible Current Measuring Shunt Nominal Current Constant Current With good Cooling Max Current 15 Minutes Max Current 7 Minutes Max Current 4 Minutes Max Current 90 Seconds Max Current 20 Seconds Max Current 5 Seconds Dimensions Measuring Shunt mm Weight Ambient Conditions Humidity of Air Jit 12 V 24 V 8 32 V 4 0 40 mA depending on illumination Lead Acid Gel AGM LiFePo4 LiFeYPo4 Nominal Voltage 13 3 V o 26 6 V LC Display with
13. ntrast LC display Depending on the angle of view the contrast of the display might be too weak or too high hidden characters are visible The contrast can be quickly adapted by pressing the buttons 1 and 3 increase contrast simultaneously or by pressing the buttons 2 and 3 reduce contrast simultaneously re Displays Battery Computers Use the buttons 1 and 2 to display the next or previous page of the measuring and display values Voltage Display of the voltage of the board battery B1 and of a second battery B2 such as the starter battery is possible The marking triangles at the lower edge of the display point to the displayed battery Current The current display informs of the instantaneous load or battery charge The display shows the instantaneously measured value flowing into or out of the battery If the current flows into the battery the display will show a positive current value and the charging symbol CHARGE If the current flows out of the battery it is negative and the value will be shown with a negative sign Capacity Display The microcomputer controlled measurement accurately counts each ampere hour Ah of capacity during charging and discharging even in splits The automatic evaluation of the battery load is effected by means of the programmed characteristic lines of the battery So a current rate of e g 100 Amperes represents an inferior load for a 600 Ah battery while this is an extremely hi
14. r objects to clean the front panel and particularly the display itself Failure Corrective Action No display at all a Reverse battery Check b Battery is totally discharged below 7 volts Recharge immediately c Connection cable is interrupted damaged or it is not inserted Check Hieroglyphs on the display a The internal check programs of the unit have found an memory error Withdraw the cable connector for 10 seconds After that an initial start up is to be executed as described above Wrong current display a Permanent display of high current A Check the connection cable for correct contact and damage b The display does not show 0 0 A after disconnection of all consumers and chargers Check if hidden current consumers are existing Check if the contact of the connection cable is correct and if it is damaged Check if condensation water or humidity exists in the display unit Safety Instructions Safety Regulations and Appropriate Application The LCD Battery Computer S with Measuring Shunt has been designed according to the valid safety mg AE PS a regulations Appropriate application is restricted to Control of commercial types of lead storage batteries lead acid gel AGM as well as LiPoFe of the indicated nominal voltage and of connected consumers in fixed installed systems With observation of the capacity limits of the measuring shunt see Technical Data Together wi
15. th the supplied measuring shunt Technically faultless condition Installation in a well ventilated room protected from rain humidity dust aggressive battery gas as well as in an environment being free from condensation water With a rear insulating cover of the display unit Never use the unit at locations where the risk of gas or dust explosion exists Open air operation of the unit is not allowed Cables are always to be laid in such a way that damage is excluded Observe to fasten them tightly Never lay 12 V 24 V cables and 230 V mains supply cables into the same cable conduit empty conduit Check live cables or leads periodically for insulation faults points of break or loosened connections Occurring defects must be remedied immediately The unit is to be disconnected from any connection prior to execution of electrically welding or work on the electric system If the user is not able to draw from the manual which characteristic values are valid for a unit or which regulations are to be observed a specialist is to be consulted The user buyer is obliged to observe any construction and safety regulations Keep children away from the batteries and the measuring shunt Observe the safety regulations of the battery manufacturer Ventilate the battery room Always use the same car fuses for replacement The unit is not equipped with parts which can be replaced by the user Non observance may result in injury or material da
16. ty can be reset For this the button 1 and 2 must be pressed simultaneously for 3 seconds at the respective display The value is deleted and the display shows A counter shows the time in hours that have passed from the last 100 charging Adjustment of the Background Illumination The background illumination can be adapted from bright to completely dark in steps of 10 according to the requirements General Information Once a year e Check the connecting screws at the measuring shunt for tightness e Check the connection cable for correct contact and damage e Aged batteries Lead batteries are subject to wear which will be growing with the age of the battery the number of charging discharging cycles the rate of discharge frequent total discharge and other factors such as extreme temperatures vibration etc This results in a reduction of the available capacity The LCD Battery Computer S is able to consider this loss of capacity in calculation within certain limits However we recommend to correcting the set nominal capacity by e g 5 depending on the battery type and the operating conditions 2 10 lower once a year Cleaning We recommend to use a damp microfibre cloth with pure water or if required with water with a few soap Take care that no liquid flows along the display screen or the edges of the front panel Never use solvents aggressive household cleaners and scratching or abrasive agents o