Home

English - Ucoffee

image

Contents

1. ACCOUNTING DE OUNTERS MEN O B c Q10 Tec rev 1106 2 Programming How to enter Programming menu there are two possibilities Access and modification of subamenus Wee he 30 and 1 Insert the smart card 31 keys to position the cursor on the desired line then press 2 without the smart card reader the PRG 0 29 key place the dip 5 of the main CPU board in ON position then push in the following sequence the OK button and PRG x KEY MENU 29 button Keep pushed the PRG C 29 button for at least 3 seconds repetition 001 Besides the date and hour the symbol TECHNICIAN will appear Water dose 170 grinder MM1 MM1 cof dose 047 Ka Sue TE AAP os OS Use the 30 and 31 keys also to modify the message or number 10 March 2010 wednesday 15 15 04 Note When modifying data the cursor changes to gt KKEY MENU Display of available menus Press the PRG 29 key gt Type repetition Water dose TECHNICAL PROG KEY MENU CONFIGURATION TESTING grinder MM1 cof dose WEIGHTING Exiting the programming menu There are two possibilities m D i 1 Press the OK key to confirm changes CES AS in ue 3o ana O D keyso position 2 Press the RES 24 key to leave settings unchanged and exit the cursor on the desired line then press the PRG 29 key press ihe mani a selection key if the SELECT KEY menu appears Q10 Tec rev 11
2. Recommended for cappuccinos or Typical for single Typical for double Typical for coffees Typical for double beverages with espressos espressos with cream coffees with cream added water Examples of use 1 Suppose you want to dispense a coffee with a recipe set for Heating mode 3 and 13 minutes have passed from the last coffee dispensed From the table above you can see that Interval 4 from 10 to 20 minutes intersects with Heating Mode 3 on the square of 5 seconds which corresponds to the duration that the boiler resistance is activated before the coffee is dispensed 2 If Heating mode 1 is set in the recipe and 4 minutes have passed from the last coffee dispensed from the table above you can see that Interval 2 from 2 to 5 minutes intersects with Heating Mode 1 on the square of 3 seconds of boiler heating If Heating mode 1 is set in the recipe and 18 minutes have passed from the last coffee dispensed from the table above you can see that Interval 4 from 10 to 20 minutes intersects with Heating Mode 1 on the square of 7 seconds of boiler heating Q10 Tec rev 1106 3 Key menu Coffee selection Press one ofthe coffee dispensing keys 32 the relative led will remain on The following message will appear on the display gt KEY MENU Type 1 coffee repetition 001 Water dose grinder MM1 cof dose The following coffee selection parameters can be modified Type key personalizing e g 1 coffee 1
3. SPECIAL KEY parameter YES SPECIAL KEYS parameter choice At this point when the special key is pressed 25 and one of the dispensing keys is pressed corresponding to the desired beverage and dosage the second beverage programmed for the selected dispensing key will be dispensed Recipes associated with the second selections are programmed in the Key Menu of the machine by pressing the special key 25 and then the dispensing key 15 Q10 Tec rev 1106 7 Washing options EXECUTION MODALITY Milk circuit Keep the milk circuit washing key 28 Ge pressed for a few seconds and follow the instructions indicated on the display Coffee circuit Keep the coffee circuit washing key 26 pressed for a few seconds and follow the instructions indicated on the display Solubles circuit Keep the coffee circuit washing 26 and milk circuit washing 28 keys pressed for a few seconds The cycles can be activated with the same modality also without a washing demand In order to get more detailed information please consult the machine use and installation manual WASHING OPTIONS includes seven sub menus for setting washing parameters one of which to program the soluble circuit washing cycle gt K WASHING OPTIONS autom washing 20 SOLUB WASHING WASHING 1 WASHING 2 WASHING 3 Gm Afr p Aip 3 Washing options Automatic washing Depending on the selected setting OFF 3 99 the automatic
4. E Disconnect the coffee tube from the dispensing nozzle and if present the tubes for soluble beverages and water from the nozzle then completely open the front panel E Appuyer surle pivot de fermeture C et ouvrir partiellement le panneau frontal E D brancher le tuyau de caf du bec de d bit et si besoin est les tuyaux des solubles et de l eau du bec puis appuyer compl tement sur le panneau frontal E Auf den Sperrstift C dr cken und das Frontpaneel E teilweise ffnen Die Kaffeeleitung und sofern pr sent die Leitungen f r l sliche Produkte und Wasser vom Ausflu 3st ck abziehen anschlie end kann das Frontpaneel E ganz ge ffnet werden Presionar el perno de cierre C y abrir parcialmente el panel frontal Y Desconectar el tubo de caf de la boquilla erogadora y si est n instalados los tubos de los productos solubles y del agua de la boquilla por ltimo abrir completamente el panel frontal Y Premir o pino de fecho C e abrir parcialmente o painel dianteiro E Desconectar o tubo do caf do bico distribuidor e se presentes os tubos dos sol veis e da gua do bico e por fim abrir completamente o painel dianteiro E 36 Q10 Tec rev 1106 Rimozione gruppo caffe Coffee group removal Retrait du groupe de caf Ausbau Kaffeeabgabeeinheit Desmontaje del grupo caf Remoc o do grupo caf Per facilitare il riposizionamento del gruppo caff accendere la macchina e premere il ta
5. adhesive plate inside the machine Proceed with assembling the group and connecting the water tubes and electrical connectors Amener manuellement la manivelle du groupe G en fin de course s en tenir la plaquette adh sive plac e l int rieur de la machine puis proc der au montage du groupe et au branchement des tuyaux hydrauliques et des prises lectriques Die Welle der Einheit G bis zum Anschlag positionieren siehe Klebeschuld im Innenbereich der Maschine anschlieRend die Einheit einsetzen und die Wasserleitungen und die elektrischen Steckverbinder wieder anschlieRen Colocar manualmente la manivela del grupo G en el final de carrera atenerse a la tarjeta adhesiva colocada en el interior de la m quina luego realizar el montaje del grupo y la conexi n de los tubos hidr ulicos y los conectores el ctricos Deslocar manualmente a manivela do grupo G at alcancar o fim de corrida respeitar o que consta da placa adesiva posicionada no interior da m quina em seguida proceder montagem do grupo e conex o dos tubos hidr ulicos e dos conectores el ctricos 38 Q10 Tec rev 1106 Rimozione tramogge caffe Coffee receptacle removal Retrait des tr mies de caf Ausbau Kaffeetrichter Desmontaje de las tolvas de caf Remoc o das tremonhas do caf chiuso closed ferm geschlossen cerrado fechado Spingere il dispositivo di chiusura tramoggia H verso il retro della macchina Push th
6. separar a tremonha sol vel da m quina Q10 Tec rev 1106 Rimozione gruppo macinini Grinder group removal Retrait du groupe des moulins Ausbau Mahlwerk Desmontaje del grupo molinillos Remoc o do grupo moinhos Rimuovere le 3 viti A situate nella parte anteriore della macchina Remove the 3 screws A on the front part of the machine Retirer les 3 vis A situ es dans la partie ant rieure de la machine Die 3 Schrauben A auf der Vorderseite der Maschine l sen Desmontar los 3 tornillos A situados en la parte anterior de la m quina Remover os 3 parafusos A situados na parte anterior da m quina Rimuovere il pannello superiore S Remove the top panel S Retirer le panneau sup rieur S Das obere Paneel S abnehmen Desmontar el panel superior S Remover o painel superior S 41 Rimuovere le 2 viti P situate nella parte posteriore della macchina Remove the 2 screws P at the back of the machine Retirer les 2 vis P situ es dans la partie post rieure de la machine Die beiden Schrauben P auf der R ckseite der Maschine l sen Desmontar los 2 tornillos P situados en la parte posterior de la m quina Remover os 2 parafusos P situados na parte posterior da m quina Svitare le viti di fissaggio indicate in figura e rimuovere il gruppo macinini Unscrew the fastening screws indicated in the figure and remove the grinder group D visser les vis de fixation indiqu es sur la figure et re
7. 5 These are scheduled washes that are independent of the wash cycles related to the switching on and switching off phases At the set hour the messages EXECUTE WASHING GROUP EXECUTE WASHING MILK CIRCUIT appear according to the programmed washing After having positioned the cursor on the line to be changed and after having pressed the PRG 29 key change the value using the 30 and 31 keys Then press the OK key to confirm Repeat the above operations to change the other wash scheduling times Wash 1 When this function is requested a long wash cycle is performed milk circuit and coffee circuit as described in the Cleaning operations paragraph of the user manual NOTE Wash 1 cannot be disabled It is requested daily at the programmed hour and always within 24 hours Washes 2 5 If the set hour for these wash cycles occurs when the machine is switched off the request will be canceled NOTE Set OFF against the time so as to not activate these wash cycles OFF is displayed press the 31 key the indicated time is 00 00 For more details please consult at the Configuration menu wash options paragraph Date and time To modify the date and hour press the PRG 29 key for the corresponding line The following message will appear A DATE AND TIME Month 04 APR Date 21 WED 17 H 12 I Hour Minutes acr Su YL die us 27 Use the 30 and 31 keys to move the curs
8. Emulsion Cappuccino selection parameters that can be changed are Type key personalizing e g 1 coffee 1 cappuccino 1 milk 1 soluble 1 1 soluble 2 1 mix soluble 2 coffees 2 cappuccini 2 milks 2 solubles 1 2 solubles 2 2 mix solubles stop water null repetition it represents the number of distributions of the selected drink from 001 to 099 Milk dose milk dispensing time O 60 seconds with increments of 0 1 Milk start coffee start milk dispensing delayed after coffee dispensing and vice versa Emulsion foamed milk dispensing time from O to 60 with increments of 1 second HM FM this parameter lets you decide which type of milk frothed or regular to dispense first YES regular milk frothed milk NO frothed milk regular milk cold milk dose cold milk dose from O to 20 with increments of 0 1 seconds v Mpl cold milk cold milk pump motor speed from 10 to 55 with increments of 1 v Mpl hot milk hot milk pump motor speed from 1096 to 55 with increments of 1 Setting a value of less than 35 is recommended Milk temperature depends from this parameter low value high milk temperature high value low milk temperature v Mpi milk HM hot hot regular milk pump motor speed from 10 to 55 with increments of 1 Setting a value of less than 35 is recommended Milk choice between two types of milk if function is activated water dose volum
9. cappuccino 1 milk 1 soluble 1 1 soluble 2 1 mix soluble 2 coffees 2 cappuccini 2 milks 2 solubles 1 2 solubles 2 2 mix solubles stop water null repetition it represents the number of distributions of the selected drink from 001 to 099 Water dose volumetric dosage pulses from O to 999 with increments of 1 grinder MM grinder number 1 left 2 right MM coffee dose grinde encoder pulses 0 200 with increments of 1 start water determines if water is added at the beginning or end of coffee dispensing can be set before or after water add volumetric dosage pulses from O to 999 with increments of 1 heating mode acts on the brewing temperature can be set from O to 4 See specific paragraph infusion infusion time O 6 seconds with increments of 0 1 drying pod drying time O 5 seconds with increments of 0 1 Note the coffee doses for the grinders set in the technical programming menu are subject to change in the customer programming menu within a range of 5 of the set value 3 1 Key menu Milk selection Press one of the milk dispensing keys 32 the relative led will remain on The following message will appear on the display KKEY MENU d Type 1 milk im repetition OO1 Milk dose O7 0 Emulsion O7 O IHM FM NO A dp E E e Milk selection parameters that can be changed are Type key personalizing e g 1 coffee 1 cappuccino 1 milk 1 so
10. circuit 31 Washing 31 Components 32 rev 1106 Q10 Tec rev 1106 12 13 14 15 SM DESCRIPTION OF THE COMPONENTS Delivery spout Selection panel Graphical display Coffee hoppers 1 Coffee hoppers 2 Soluble hoppers Hot water button Steam dispensing button Hot water outlet Steam pipe Tray Main switch RES key to quit programming mode Special key Coffee circuit flushing key short washing i key displays the number of cycles Milk circuit wash key automatic wash PRG key to access programming mode menu key to modify parameters clock key to modify parameters clock Beverage selector key CUSTOMER PARAMETERS key Card services slit technical programming bean key coffee dose variation OK key stops products from being dispensed Input data confirmation key Sleep mode button The components are applied only in some produit configurations Insert the TECHNICIAN smart card Q10 Tec rev 1106 1 Data flow chart Technician programming 1 3 Milk HM FM Cold milk dose v Mpl cold milk v Mpl hot milk v Mpl milk HM hot without the smart card reader place the dip 5 of the main CPU board in ON position then push in the following sequence the OK button and PRG button Keep pushed the PRG button for at least 3 seconds KEY MENU Press SELECTION KEY Repetition v Mpi milk HM
11. con la m quina APAGADA En condiciones est ndares los Dip switch est n colocados en OFF Por medio de los Dip Switch O se activan las siguientes funciones DIP 1 OFF ON introducci n datos est ndares DIP 2 OFF DIP 3 OFF ON simulaci n llave t cnico DIP 4 OFF ON contabilidad DIP 5 OFF ONhabilita la secuencia de teclas para entrar en programaci n DIP 6 OFF DIP 7 OFF DIP 8 OFF Al final de las operaciones de introducci n datos est ndares res tablecer el DIP 1 a la posici n OFF ATEN O A mudan a de posi o dos Dip Switch dever ser efectuada RIGOROSAMENTE com a m quina DESLIGADA Nas condi es standard os Dip Switch est o posicionados em OFF Actuando nos Dip Switch O activam se as fun es a seguir indicadas DIP 1 OFF ON introdu o dados standard DIP 2 OFF DIP 3 OFF ON simula o chave t cnico DIP 4 OFF ON contabilidade DIP 5 OFF ON habilita a sequ ncia das teclas para entrar em programa o DIP 6 OFF DIP 7 OFF DIP 8 OFF No fim das opera es de introdu o dos dados standard recolo car o DIP 1 na posi o OFF
12. dispensing starts and 5 seconds after the selection key is pressed milk is dispensed Note lf the time setting exceeds the coffee dispensing time milk dispensing begins immediately after coffee is dispensed Start coffee 00 Coffee dispensing starts after milk is dispensed Start coffee 99 or any setting other than O coffee dispensing will start 99 seconds or after the set time after milk is dispensed Q10 Tec rev 1106 3 3 Key menu Soluble selection Press one of the soluble dispensing keys 32 the relative led will remain on The following message will appear on the display KEY MENU Type 1 soluble 1 repetition mixer delay time mixer predose mixer Soluble selection parameters that can be changed are Type key personalizing e g 1 coffee 1 cappuccino 1 milk 1 soluble 1 1 soluble 2 1 mix soluble 2 coffees 2 cappuccini 2 milks 2 solubles 1 2 solubles 2 2 mix solubles stop water null repetition it represents the number of distributions of the selected drink from 001 to 099 mixer delay YES NO enables disables the mixer delay time function of the SOLUBLE PARAMETERS entry in the CONFIGURATION menu When this function is enabled the mixer keeps functioning for the set time even after the Gsol soluble solenoid valve has closed This parameter allows the mixer chamber to empty completely mixer time mixer activation time between 0 and 30 seconds with incremen
13. ho Cappuccino offee start Milk start HM FM old milk dose v Mpl cold milk v Mpl hot milk t Water dose MM coffee dose Water add Heating mode 3 To EXIT menu press RES Soluble Mixer dela Time mixer Predose mixer redose dispense Dispenser delay Dispenser type ot time dispense t on dispenser t off dispenser H20 dela Cycle dela To ACCESS menu press PRG Q10 Tec rev 1106 1 Data flow chart Technician programming 2 3 CONFIGURATION TESTING WEIGHTING Press Press 7 DE Press 7 DE SPECIAL KEY SPECIAL KEYS Boiler P Level sensib BOILER CO OLUB PARAMETERS OLUB PARAMETERS TURBOSTEAM ESAUREMENT UNIT N grounds HANGE W FILTE Customer prog Bean ke Prog lock Paym system StandBy Leds Stop dispens Standard data DATA IN OUT Archive reset MAINTENANCE uN lt e Q 12 Cn TI T 5 ZU O Sr E QD 5 u 9 Z dp X X CO N PAY PER USE Ss ARDWARE SETU a without the smart card reader place the dip 5 of the main CPU board in ON position then push in the following sequence the OK button and PRG button Keep pushed the PRG button for at least 3 seconds 4 CUSTOM PARAMETERS Press 1 Q10 Tec rev 1106 Data flow chart Technician programming 3 3 DATA MENU Press COUNTERS MEN d DE NS coffees c N steam air N t coffee N cycles
14. le operazioni IMPORTANT WARNINGS WARNING These chapters in the manual are to be used by qualified authorized technical staff Switch off the power to the machine before performing these steps F AVIS IMPORTANTS ATTENTION Ces chapitres du manuel sont l usage du personnel technique qualifi et autoris D brancher la machine avant d effectuer toutes les op rations D WICHTIGE WARNUNGEN ZU BEACHTEN Diese Kapitel des Handbuches wenden sich an qualifizierte und offiziell befugte Fachtechniker Vor Ausf hrung gleich welcher Arbeitsschritte die Spannungsversorgung der Maschine unterbrechen E ADVERTENCIAS IMPORTANTES ATENCI N Estos cap tulos del manual son para su uso por parte del personal t cnico cualificado y autorizado Desconectar la tensi n de la m quina antes de efectuar todas las operaciones P AVISOS IMPORTANTES ATENGAO Estes cap tulos do manual s o para serem utilizados pelo pessoal t cnico qualificado e autorizado Retirar a tens o m quina antes de executar todas as opera es Gli interventi sul gruppo caffe richiedono operazioni da effettuare con macchina accesa Any work performed on the coffee group must be done with the machine switched on Les interventions sur le groupe de caf requi rent des op rations devant tre effectu es lorsque la machine est allum e Die auf die Kaffeeabgabeeinheit bezogenen Arbeitsschritte m ssen bei eingeschalteter M
15. malfunctioning The movement is requested while the coffee grounds drawer is absent 009 The coffee group piston has not reached the The compression sensor is dispensing zone and the positioning timeout malfunctioning was reached because the compression The limit switch signal is lost sensor did not intervene The fastening screw is loose and the group is being pulled in an abnormal way by the motor crank 011 MM1 grinder encoder impulses are not The grinder is blocked read The grinder is malfunctioning The encoder is malfunctioning 021 MM2 grinder encoder impulses are not The encoder photocell was read incorrectly installed 025 No power to group solenoid valve milk The switching power supply is pump malfunctioning The wiring is disconnected There has been a power outage 041 The overcurrent alarm sounds when the There is excessive stress during milk pump starts functioning The gear pump MRL MRC is malfunctioning 051 The boiler temperature is not working The sensor is electrically disconnected The sensor is malfunctioning There is a CPU card malfunction 052 Boiler heating timeout The resettable safety thermostat has intervened The heating element has been disconnected The Triac card is malfunctioning The heating element wiring and or Triac control is disconnected 056 The boiler temperature sensor is not working e The temperature sensor is Value is out of range malfunctioning The temperatur
16. soluble beverage dispensing cycle the timer countdown starts Afterwards the request for a wash cycle message appears on the display block solub soluble block When the function is set YES if the wash cycle is not performed within 60 from the time when the hir message appears the machine is blocked and prevents all soluble Ok ep 1 6 die 95 Y beverage selections stop solub Washing options Washing 1 2 3 4 5 These are wash cycles set at programmable times each with four type indicates type of wash cycle that will be performed Long wash changeable parameters which are coffee circuit and milk circuit with detergent coffee stop when the function YES is set if the wash cycle does WASH 1 not take place within 60 30 if short washing from the moment that OO 00 the EXECUTE WASHING GROUP message appears the machine long is blocked and all selections for coffee are inhibited coffee stop YES milk stop when the function YES is set if the wash cycle does milk stop YES not take place within 60 30 if short washing from the moment that H the EXECUTE WASHING MILK CIRCUIT message appears the R E die YL dP gs machine is blocked and all selections for milk are disabled NOTE if the block coffee and block milk entries are set to NO for hour when the wash cycle must be performed the WASH 1 cycle the machine will never be blocked WASH 1 cannot be disabled It is
17. type of soluble beverage COFFEE contains all the parameters described in the Coffee Selection paragraph MILK contains all the parameters described in the Milk Selection paragraph Q10 Tec rev 1106 Soluble Mix selection Mixed Start function With the START COMBO function you can program the sequence of dispensing cycles for coffee milk and soluble beverages to obtain the desired combination KKEY MENU Type 1 mix soluble g repetition 001 MIXED START YES 06 0 A mixer delay time mixer Ka we TE die os When the PRG 29 key is pressed the display will show the following coffee start step K 090 Clm 74 05 1 o4 0s The line on which the cursor is positioned is associated with the coffee beverage the following lines refer respectively to milk soluble 1 and soluble 2 The duration of the separate beverage cycles set in the recipe is represented by rectangles to the right or inside of which shows the pulses for coffee the total duration in seconds for milk and soluble beverages Using the 30 and 31 keys to position the cursor b on a beverage the following parameters are automatically displayed on the first 2 lines start dispensing delay of the selected beverage can be set be tween 0 90 seconds with increments of 1 or with the OFF option that disables the corresponding beverage step dispensing sequence of the bev
18. 02 08 SET 2010 jD G die vr wu os NX Use the A 30 and Y 31 keys to scroll through the failed wash cycles then press the RES 24 key to pass to another menu Q10 Tec rev 1106 15 DATA menu MALFUNCTIONS ARCHIVE zk DATA MENU decido 29 key is eee SCH the details page is accessed COUNTERS MENU e following appears on the display day and hour when the error occurred ACCOUNTING machine status when the error occurred INFO WASH ARCHIVE MALFUNCT ARCHIVE 5 caw Vip E d r E ve If the PRG 29 key is pressed when the cursor is on the error log line the following appears on the display gt MALFUNCTION DETAIL Monday 25 10 10 13 36 25 066 GR1 GR coffee KMALFUNC ARCHIVE 01 O66 OOO12 25 02 066 00000 03 O3 003 00001 30 04 003 00000 00 05 003 00000 30 a RP YL ip ab X The figures appearing after the error code indicate in hours and minutes the time that has passed since the last recorded error 16 Customer parameters menu To access Customer parameters press 34 key the following CUSTOMER PARAMETERS message will appear on the display P ITALIANO ENGLISH DEUTSCH FRANCAIS a ite YL die os Language selection To display the messages in a different language from that set after entering into Programming mode position the cursor on the desired CUSTOMER PARAMETERS t language by pressing the A 30 and S 31 keys and the
19. 06 2 1 STOP Function Dispensing of the selected beverage can be stopped before the Note If the Stop dispensing parameter is not set in the machine programmed dose is reached in two ways configuration menu NO the OK key stops dispensing 1 by setting a selection key with the STOP function Once the OK button is pushed it does not change the programmed 2 by setting the Stop dispensing parameter in the machines parameters configuration menu Note in this case the selection key also functions as the START STOP key 2 2 Heating Mode The heating mode is a setting that maintains the optimum brewing How to program temperature for each type of coffee beverage Nine heating modes from O to 8 can be set in the recipes active modes ranging from O to 4 those from 5 to 8 are not active and are associated with the heating mode O Each mode from O to 4 regulates the coffee boiler heating time divided into 5 intervals Each interval is related to the time passed from the last coffee dispensed How it works When a dispensing key is pressed the coffee boiler resistance is activated for the time needed to reach the correct brewing temperature The coffee boiler heats when the dispensing cycle is launched and during grinding before the brewing phase begins Heating modes with related boiler resistance activation times Interval Value Heating mode 0 Heating mode 1 Heating mode 2 Heating mode 3 Heating mode 4
20. 1 2 Using the 30 and 31 keys select the parameters then press the PRG 29 to confirm the details After this operation switch off the machine and reset the dipswitch 1 display screen to OFF Then Switch on the machine again Mol STANDARD GEAR H2O NO OK YES Solub1 YES Solub2 YES SPEC KEYS H2O NO Reset date and time and reset the desired language if needed press 34 key press the PRG 29 key press again the PRG 29 key reset maintenance parameters press the PRG 29 key press again the PRG 29 key zero the error and wash log 24 CUSTOMER PARAMETERS SERVICE TIME H ITALIANO ENGLISH DEUTSCH L v FRANCAIS com rr NS SERVICE TIME DATE AND TIME y ON time 03 00 OFF time 03 00 Day off none q Night ON 02 00 Z car AP 55 Xx DATE AND TIME Month Date Hour Minutes o i e in TECHNICAL PROG n KEY MENU TESTING WEIGHTING H Be e GE de CONFIGURATION standard data NO DATA IN OUT Archive reset NO MAINTENANCE PAY PER USE LI o dir Y dr a Va Q10 Tec rev 1106 Dip settings The dip setting entry displays the dipswitch settings DIP SETTINGS TS 12345678 OFF 14 DATA menu DATA MENU COUNTERS MENU ACCOUNTING INFO WASH ARCHIVE MALFUNCT ARCHIVE P Ka die Te wu og OS Press the PRG 29 key the following message appears on the display K WASH ARCHIVE 1 Performe
21. 3 vis de fixation B indiqu es dans la figure d brancher le connecteur T de la carte CPU et extraire l ensemble chaudi re chauffe eau Die 3 in der Abbildung gezeigten Schrauben B l sen den Steckverbinder T von der CPU Karte abziehen und die Einheit Wasserkessel Boiler herausnehmen Destornillar los 3 tornillos de fijaci n B indicados en la figura desconectar el conector T de la tarjeta CPU y desmontar el grupo caldera calentador Desparafusar os 3 parafusos de fixac o B indicados na figura desconectar o conector T da ficha CPU e extrair o conjunto caldeira boiler 45 Q10 Tec rev 1106 Rimozione assieme pompe Pump assembly removal Retrait de l ensemble pompes Ausbau Pumpeneinheit Desmontaje del grupo bombas Remoc o do conjunto das bombas Prima di procedere con lo smontaggio scollegare tutti i tubi idraulici e i connettori elettrici collegati all assieme pompe Before removal disconnect all the water tubes and electric connectors connected to the pump assembly Avant de proc der au montage d brancher tous les tuyaux hydrauliques et les prises lectriques reli s l ensemble pompes Vor dem Ausbau die Wasserleitungen und die elektrischen Steckverbinder von der Pumpeneinheit abziehen Antes de realizar el desmontaje hay que desconectar todos los tubos hidr ulicos y los conectores el ctricos conectados al grupo bombas Antes de proceder desmontagem desconectar todos os tubos hidr ulicos e os co
22. Com a ajuda de uma ferramenta rodear para a esquerda o dispositivo de fixac o Fs Aprire la serratura della tramoggia Ts e rimuovere il coperchio Open the hopper lock Ts and remove the cover Cs Ouvrir la serrure de la tr mie Ts et retirer le couvercle Cs Entsperren Sie die Sperrvorrichtung des Trichters Ts und nehmen Sie die Abdeckung Cs ab Abrir la cerradura de la tolva Ts y quitar la tapadera Cs Abrir a fechadura da tremonha Ts e remover a tampa Cs P T a Tm hu a 7 v pan Spostare la tramoggia verso la parte anteriore della macchina Move the hopper towards the front of the machine D placer la tr mie vers la partie ant rieure de la machine Schieben Sie den Trichter nach vorne Desplazar la tolva hacia la parte anterior de la m quina Deslocar a tremonha na parte dianteira da m quina 40 Sollevare leggermente la parte posteriore della tramoggia e separare la tramoggia solubile dalla macchina Slightly raise the rear of the hopper and remove the solubles hopper from the machine Soulever l g rement la partie post rieure de la tr mie et s parer la tr mie soluble de la machine Heben Sie den r ckseitigen Teil des Trichters leicht an und nehmen Sie den Trichter f r l sliche Produkte von der Maschine ab Levantar ligeramente la parte posterior de la tolva y separar la tolva para solubles de la m quina Levantar levemente a parte traseira da tremonha e
23. Place the provided coffee scoop next to the ground coffee chute and press the selection key that needs checking gt TECHNICAL PROG KEY MENU CONFIGURATION TESTING EIGHTING When the PRG 29 key is pressed the following will appear on the display K K K WEIGHTING x x x MM1 000 MM2 000 Scoop position ____looo looo After the grinding phase the following will appear on the display Set value After opening the control panel A the power supply is switched off Insert the technical key T in the special slot B to restore normal functioning K K K WEIGHTI MM1 000 l ooo Ground coffee value The value set in the test menu and the ground coffee value must be the same During the grinding phase make sure that the ground coffee does not slide off the scoop Once the grinding phase has ended remove the scoop from the machine and weigh the amount of ground coffee on an accurate scale Note To obtain the real weight we recommend performing the coffee grinding phase between 3 and 5 times and then calculating the average Once the weighing process is concluded press the RES 24 key 2 times in a row to bring the unit to the standby position and to exit the programming menu 21 Q10 Tec rev 1106 11 DATA menu COUNTERS Parameters calculated are N coffee number of coffee beverages Once you have entered the programming menu access the DATA MENU pressing the i 27 ke
24. Q10 Tec rev 1106 2 1 2 2 3 1 3 2 3 3 3 4 14 15 16 17 18 Index Page Page Description of the machine and DISASSEMBLY of the control panel 2 uu j Opening front panel 36 Data flow chart Technician programming 3 Programming 6 Coffee group removal 37 Stop Function 7 Coffee group repositioning 38 Heating Mode 7 Key menu Coffee selection 8 Coffee receptacle removal 39 Key menu Milk selection 8 Solubles receptacle removal 40 Key menu Cappuccino selection 9 Grinder group removal 41 Key menu Soluble selection 10 Key menu Soluble Mix selection 10 Opening the rear panel ge Soluble Mix selection R 42 Mixed Start function 11 ear panel cover remova Key menu Hot water selection 12 Thermostat reset 43 Key menu Steam selection 12 Water inlet assembly removal 43 TEST board 13 Configuration menu 14 Solenoid valve block removal 44 Special keys 15 Boiler heater assembly removal 45 Washing options 16 Pump assembly removal 46 Pay per Use 18 Test menu 19 Weighting 21 SETTING DATA menu Counters 22 DATA menu Accounting 22 Display contrast setting 47 DATA menu INFO 23 CPU Dip Switch 48 Serial number 23 Version 23 Setup 24 Entering Standard Data 24 Dip settings 25 DATA menu Wash Archive 25 DATA menu MALFUNCTIONS ARCHIVE 26 Customer parameters menu 26 Language selection 26 Service time menu 27 Date and time 27 Defects Malfunctions 28 Abnormal functioning machine and operator 30 Coffee circuit 30 Milk
25. The ground coffee dose is higher than underneath the group left part maximum dose allowed The dispensing group receptacle is Triac grinder has short circuited clogged with coffee the dispensing group The setting for the ground coffee dose is is blocked and full of coffee incorrect and higher than the maximum Total blockage ofthetube can mechanically capacity of the coffee group block the grinder blade The machine does not switch on The display panel is not closed correctly There is no electrical power supply The ON OFF switch is off or malfunctioning The water boiler and steam boiler The wiring is disconnected malfunctioning temperature do not increase The safety thermostats have intervened The Triac has short circuited The display is off The display card is malfunctioning The switching power supply is malfunctioning The wiring is disconnected The programming keypad is not working The programming block is enabled The programming keypad card key switch is malfunctioning The wiring is disconnected The Selection keypad is not working The key on the keypad is disabled The programming keypad card key switch is malfunctioning The wiring is disconnected The LED key on the Selection keypad is The key on the keypad is disabled not working The programming keypad card key switch is malfunctioning The wiring is disconnected There is no lighting on the machine work The lighting LEDs are malfunctioning surfac
26. a e premere il tasto sleep mode SM attendere qualche secondo quindi rispegnere la macchina Ifthe motor crank M is notin the correct position Figure B switch on the machine and press the Sleep Mode key SM Wait a few seconds and then switch off the machine Au cas ou la manivelle du moteur M ne se trouverait pas dans la bonne position figure B mettre la machine en marche et appuyer sur la touche s eep mode SM attendre quelques secondes puis teindre nouveau la machine Sollte sich die Motorwelle M nicht in der korrekten Position befinden Abb B die Maschine einschalten und die Taste sleep mode 5 SM dr cken einige Sekunden abwarten und die Maschine erneut ausschalten En el caso de que la manivela motor M no se encontrase en la correcta posici n figura B encender la m quina y pulsar la tecla sleep mode SM esperar unos segundos y luego empujar la maquina Caso a manivela do motor M nao se encontre na posic o correcta figura B acender a m quina e premir a tecla sleep mode SM aguardar alguns segundos e por fim voltar a desligar a m quina Portare manualmente la manovella del gruppo G a fine corsa attenersi alla targhetta adesiva posizionata all interno della macchina quindi procedere con il montaggio del gruppo e il collegamento di tubi idraulici e connettori elettrici Manually bring the group crank G to a stop follow instructions on the
27. ador Utilizar o trimmer D colocado sobre a ficha electr nica para que sobre o mostrador se leiam as mensagens de modo claro Q10 Tec rev 1106 Dip Switch CPU CPU Dip Switch Dip Switch CPU Dip Switch CPU Dip Switch Schalter CPU Dip Switch CPU BEER DE rire BS wh 4 O LL r HS ATTENZIONE Il cambiamento di posizione dei Dip Switch deve essere effettuato RIGOROSAMENTE a macchina SPENTA Nelle condizioni standard i Dip Switch sono posizionati su OFF Agendo sui Dip Switch O si attivano le seguenti funzioni DIP 1 OFF ON inserimento dati standard DIP 2 OFF DIP 3 OFF ON simulazione chiave tecnico DIP 4 OFF ON contabilit DIP 5 OFF ON abilitazione sequenza tasti per ingresso in programmazione DIP 6 OFF DIP 7 OFF DIP 8 OFF Al termine delle operazioni di inserimento dati standard riportare il DIP 1 sulla posizione OFF CAUTION When changing the position of the Dip Switch the machine MUST BE SWITCHED OFF Under standard conditions the dip switches are positioned on OFF The dip switches O have the following functions DIP 1 OFF ON Input of standard data DIP 2 OFF DIP 3 OFF ON Simulation of engineer s key DIP 4 OFF ON Bookkeeping DIP 5 OFF ON allows keys sequence to enter programming DIP 6 OFF DIP 7 OFF DIP 8 OFF Upon completion of the standard data input operations position DIP 1
28. aschine ausgef hrt werden Las intervenciones en el grupo caf requieren operaciones que se tienen que efectuar con la m quina encendida As interven es no grupo caf exigem opera es a efectuar com a m quina acesa 35 Q10 Tec rev 1106 Apertura cruscotto pannello frontale Opening front panel Ouverture du tableau de bord du panneau frontal Offnen der Armaturentafel Frontpaneel Apertura del panel de mandos panel frontal Abertura do quadro de comandos painel dianteiro Aprire la serratura A e il cruscotto comandi B Open the lock A and the control panel B Ouvrir la serrure A et le tableau de bord B Die Verriegelung A und die Armaturentafel B ffnen Abrir la cerradura A y el panel de mandos B Abrir a fechadura A e o painel de comandos B Alzare il becco erogatore 1 Raise the dispensing nozzle 1 Rimuovere la bacinella 16 Remove the tray 16 Lever le bec de d bit 1 Das Ausfluf st ck 1 anheben Retirer la bassine 16 Die Wanne 16 herausnehmen Levantar la boquilla erogadora 1 Levantar o bico distribuidor 1 Desmontar la bandeja 16 Remover o tabuleiro 16 Premere il perno di chiusura C e aprire parzialmente il pannello frontale E Scollegare il tubo caff dal becco erogatore e se presenti i tubi solubili e acqua dal becco quindi aprire completamente il pannello frontale E Press the closing pin C and partially open the front panel
29. d 00005 PARTIALS Ka SU YL e ab The parameters for the WASH ARCHIVE log that can appear on the display are Requests number of wash cycles that have been requested by the machine Executed number of wash cycles that were performed within the timeout time of 60 PARTIALS in this parameter are collected all the relevant details of the 5 washing cycles wash cycles requested by the machine wash number number of washing cycles executed Under standard conditions the dip switches are positioned on OFF DIP 1 OFF ON Input of standard data DIP 2 OFF DIP 3 OFF ON Simulation of engineer s card DIP 4 OFF ON Simulation of bookkeeping s card DIP 5 OFF ON allows keys sequence to enter programming DIP 6 OFF DIP 7 OFF DIP 8 OFF For more details please consult the technical manual at the Setting CPU Dip Switch paragraph WASH ARCHIVE Pushing the PRG 29 button when the cursor is on the PARTIALS line on the display will appear Req Wash Perf 010101074 1 00000 00000 00003 00000 00000 00000 00000 00000 00000 Ra we YL die os NOTE If the wash cycles requested occur during the timeout under the entry PARTIALS you will also see a list of the last 10 failed wash cycles with progressive number date and wash number The first line refers to the most recent date VVASH ARCHIVE Required 00005 s Performed 00005 PARTIALS 01 10 SET 2010
30. da CPU connettore Y14 Before removal disconnect all the water tubes and electric connectors connected to the boiler heater NOTE the temperature probe T is directly connected to the CPU card Y14 connector Avant de proc der au montage d brancher tous les tuyaux hydrauliques et les prises lectriques reli s l ensemble T chaudiere chauffe eau NOTE le capteur de la temp rature T est reli e directement la carte CPU connecteur Y14 Vor dem Ausbau die Wasserleitungen und die elektrischen Steckverbinder von der Einheit Wasserkessel Boiler abziehen ANMERKUNG Der Temperaturf hler T ist direkt an der CPU Karte angeschlossen Steckverbinder Y14 Antes de realizar el desmontaje hay que desconectar todos los tubos hidr ulicos y los conectores el ctricos conectados al grupo caldera calentador NOTA la sonda temperatura T est conectada directamente a la tarjeta CPU conector Y14 Antes de proceder desmontagem desconectar todos os tubos hidr ulicos e os conectores el ctricos conectados ao conjunto da caldeira boiler NOTA a sonda da temperatura T est ligada directamente ficha CPU conector Y14 Svitare le 3 viti di fissaggio B indicate in figura scollegare il connettore T dalla scheda CPU ed estrarre l assieme caldaia boiler Unscrew the 3 fastening screws B indicated in the figure Disconnect the connector T from the CPU card and remove the boiler heater assembly D visser les
31. e The wiring is disconnected The Safety valve has intervened There is an anomalous reading by the boiler pressure sensor tube blocked sensor malfunction etc The boiler is flooded The level sensor is malfunctioning There is liquid dripping from the machine The seal on the draining tray connector is base worn The tray is incorrectly inserted in the machine There are noticeable variations in the The dispenser nozzle is set at the incorrect temperature and quality of the beverages height The beverages spill outside of the cups The cups are incorrectly positioned during dispensing 32 Q10 Tec rev 1106 18 Abnormal functioning machine and operator Components DESCRIPTION POSSIBLE CAUSES SOLUTIONS Continuous removed tray warning The tray micro switches are malfunctioning The wiring is disconnected Continuous removed coffee grounds tray The coffee grounds tray micro switches is warning stuck malfunctioning The wiring is disconnected When the tray is removed liquid always The connector seal is worn drips from the outlet connector The tray was removed after dispensing washing cycle without letting the system have time to correctly drain the fluids 33 Q10 Tec rev 1106 34 A Q10 Tec rev 1106 1 AVVISI IMPORTANTI ATTENZIONE Questi capitoli del manuale sono ad uso del personale tecnico qualificato e autorizzato Togliere tensione alla macchina prima di eseguire tutte
32. e hopper closing device H towards the back of the machine Pousser le dispositif de fermeture de tr mie H vers l arri re de la machine Schieben Sie den TrichterverschluR H nach hinten Empujar el dispositivo de cierre de la tolva H hacia la parte posterior de la m quina Empurrar o dispositivo de fecho da tremonha H em direc o da parte traseira da m quina Aprire la serratura della tramoggia T e rimuovere il coperchio C Open the hopper lock T and remove the cover C Ouvrir la serrure de la tr mie T et retirer le couvercle C Entsperren Sie die Sperrvorrichtung des Trichters T und nehmen Sie die Abdeckung C ab Abrir la cerradura de la tolva T y quitar la tapadera C Abrir a fechadura da tremonha T e remover a tampa C Con l ausilio di un utensile ruotare in senso antiorario il dispositivo di fissaggio F e separare la tramoggia caff dalla macchina Use a tool to turn the fastening device F counter clockwise and remove the coffee hopper from the machine Au moyen d un ustensile tourner le dispositif de serrage F dans le sens contraire des aiguilles d une montre et s parer la tr mie de caf de la machine Drehen Sie die Vorrichtung zur Trichterbefestigung F mit einem geeigneten Werkzeug gegen den Uhrzeigersinn und nehmen Sie den Trichter von der Maschine ab Con la ayuda de una herramienta girar en sentido contrario a las agujas del reloj el dispositivo de fijaci n F y se
33. e sensor wiring is disconnected There is a CPU card malfunction 28 Q10 Tec rev 1106 17 Defects Malfunctions 2 2 MALFUN COD DESCRIPTION POSSIBLE CAUSES SOLUTIONS 057 Heating boiler timeout The resettable safety thermostat has intervened The heating element has been disconnected The Triac card is malfunctioning The heating element wiring and or Triac control is disconnected 058 Overpressure alarm in boiler The Triac card is malfunctioning 059 Boiler filling timeout The water supply has been cut off The EVC is malfunctioning or electrically disconnected The check valve is malfunctioning The check valve filter is dirty There is a CPU card malfunction 064 The machine dispenses in limit switch e The ground coffee dose is below position without signaling compression nominal value 066 No reading of coffee circuit volumetric e The water supply has been cut off counter pulses during the dispensing The volumetric counter is malfun cycle ctioning or is electrically discon nected The G solenoid valve is malfun ctioning or is electrically discon nected e The pump is malfunctioning only in case of intake from reservoir The check valve filter is clogged The coffee group filters are clogged The coffee grounds are too fine 067 No reading of coffee circuit volumetric e The water supply has been cut off counter pulses during the washing cycle e T
34. eam after the dispenser activation phase between O and 5 seconds with increments of 0 1 cycle delay the time set to coincide with the closure of the dispensing cycle with the return of the machine in standby ready for the next dispensing cycle Can be set between 0 and 20 seconds with increments of 0 1 3 4 Key menu Soluble Mix selection Press one of the mix soluble dispensing keys 32 the relative led will remain on The following message will appear on the display KEY MENU 1 repetition 001 MIXED START YES 09 0 Z mixer delay time mixer Ka die YTL d r os X Mix soluble selection parameters that can be changed are Type key personalizing e g 1 coffee 1 cappuccino 1 milk 1 soluble 1 1 soluble 2 1 mix soluble 2 coffees 2 cappuccini 2 milks 2 solubles 1 2 solubles 2 2 mix solubles stop water null 10 repetition it represents the number of distributions of the selected drink from 001 to 099 MIXED START press the PRG 29 key to access a special screen where you can program the coffee milk and soluble beverage dispensing sequence to obtain the desired combination See Mixed Start paragraph on the next page SOLUBLE 1 contains all the parameters described in the Solu ble Selection paragraph related to the first type of soluble bever age SOLUBLE 2 contains all the parameters described in the Sot uble Selection paragraph related to the second
35. ed number of liters is reached the screen displays a message saying the filter must be replaced Customer programming YES NO Bean Key allows the client to change the coffee dose YES NO Programming block programming block YES NO With the function active YES the use of the programming keyboard is allowed with the technician card and keys remains always active CONFIGURATION Paym system did buzzer YES StandBy Leds 015 WASHING OPTIONS stop dispens YES y a tr YL Ip os XX Payment system permits configuration of payment system when connected Buzzer The machine buzzer can be enabled so that a beep is heard when the keys are pressed StandBy Leds not active WASHING OPTIONS See paragraph Washing options on the following pages Stop Dispensing YES NO YES each dispensing key functions as a start stop key This means that when you press the key during the dispensing phase it will be interrupted NO If the same key is pressed during the dispensing phase the repeat function is activated gt K CONFIGURATION standard data DATA IN OUT Archive reset MAINTENANCE PAY PER USE L a due TE die os XN Standard data loads standard data YES NO Q10 Tec rev 1106 DATA IN OUT contains three entries Key indicates the key number from 0 to 60 Data IN transfer from smart card to machine OUT transfer from machine to smart card TX RX to start data transfer Archive res
36. emoved even without dismantling the water inlet assembly W Retirer l ensemble de l entr e de l eau W en le tirant vers le haut Note on peut extraire le filtre F sans d monter obligatoirement l ensemble de l entr e de l eau W Die Einheit Wassereinlauf W ausbauen indem sie nach oben hin herausgezogen wird Anmerkung Der Filter F kann auch ohne Ausbau der Einheit W ausgebaut werden Desmontar el grupo de entrada agua W tirando de l hacia arriba Nota la extracci n del filtro F se puede realizar incluso sin el desmontaje del grupo entrada agua W Remover o conjunto da entrada da gua W puxando o para cima Nota a extracc o do filtro F pode ocorrer mesmo sem desmontar o conjunto da entrada da gua W 43 Q10 Tec rev 1106 Rimozione blocco EV Solenoid valve block removal Retrait du bloc EV Ausbau Einheit Magnetventile Desmontaje del bloque EV Remoc o do grupo EV Prima di procedere con lo smontaggio scollegare dal blocco elettrovalvole i tubi idraulici e i connettori elettrici Before dismantling disconnect the water tubes and electric connectors from the solenoid valve block Avant de proc der au d montage d brancher les tuyaux hydrauliques et les prises lectriques du bloc des soupapes lectriques N Vor dem Ausbau die Wasserleitungen und die elektrischen Steckverbinder von der Einheit Magnetventile abziehen Antes de realizar el desmontaje hay que desconectar del bloque de e
37. erages 1 the beverage is dispensed first 2 the beverage is dispensed second 3 the beverage is dispensed third 4 the last beverage that closes the soluble combo cycle Note Beverages in the cycle cannot be dispensed simultaneously 11 To modify the described settings start and step position the cursor on the line of the desired beverage and press the PRG 29 key The cursor will appear next to the first line on the display start XXXX B B coffee start step K 599 107 0s 14 05 EE Press the PRG 29 key again to modify the start setting The cursor will turn into gt Use the 30 and 31 keys to modify the dispensing delay for the selected beverage Press the OK key to confirm the setting The effect on the composition of the final cycle will simultaneously appear on the display B start caffe In this case the coffee beverage will have a 5 second delay on the start of the dispensing cycle Per modificare il parametro step necessario posizionare il cursore Bl suiromonima riga e premere il tasto PRG 29 il cursore si modifica in gt Mediante i tasti 30 e 31 possibile modificare la sequenza di erogazione della bevanda selezionata Premendo il tasto OK si conferma il valore immesso vedendone contemporaneamente l effetto sulla composizione del ciclo finale sul display If a coffee beverage replaces soluble beverage 2 in the cycle it will no lon
38. erator Milk circuit DESCRIPTION POSSIBLE CAUSES SOLUTIONS The machine does not dispense the The nominal boiler temperature has not requested beverages been reached There is no milk The intake tube was incorrectly positioned in the milk container The milk intake tube is clogged blocked The start settings are incorrect The gear pump is malfunctioning The milk and or concentrated chocolate The air flow regulator is malfunctioning dosage are different from the nominal The gear pump PWM setting is incorrect dose The gear pump is malfunctioning The switching power supply output voltage 24 5V Too low beverage temperature The EM solenoid valve anti suction cycle failed The solenoid valve is malfunctioning or disconnected There are limescale deposits inside the heat exchanger Steam from the steam nozzle enters the There is no milk in the refrigerator refrigerator The milk intake tube is clogged blocked The milk temperature is too hot compared The milk temperature inside the refrigerator to set temperature there is boiling inside is higher than 5 C the reference the steam nozzle temperature for the machine setting The milk intake tube is clogged blocked The milk is not frothed The EAR solenoid valve is malfunctioning or disconnected electrically The milk circuit remains full of products The water supply is cut off after dispensing The inversion setting is incor
39. ers Check that the receptacle doors are closed Check that the receptacle blocking pin is in the open position The group does not move correctly Check the correct installation of the group the connecting rod button must be inserted in the crank slot The fastening pin must be correctly locked The beverage temperature is too low too The boiler temperature is incorrect high The heating method is incorrect The safety thermostats have intervened The temperature probe is malfunctioning Ground coffee residues on the group and e The MM1 MM 2 coffee nozzles are or on the main door unprotected The coffee grounds are ground too coarsely Bubbles forming and or bad texture Air is seeping from the dispensing nozzle There are water residues inside coffee circuit tubes The tubes are incorrectly lodged inside the machine Uneven coloring There are coffee residues inside the tubes after dispensing Perform the coffee circuit washing cycle No or partial dispensing from nozzle There are problems with the water supply inlet There is a volumetric counter anomaly The tube exiting the dispensing group is partially clogged Water dripping from dispenser nozzle The coffee receptacles are empty excluding washing cycle The coffee receptacles are clogged blocked Inefficient machine discharge Check that circuit is clean and intact 30 Q10 Tec rev 1106 18 Abnormal functioning machine and op
40. ersion entry shows the memory display version When the PRG 29 key is pressed when the cursor is on each of and if present also the remote control the two lines besides showing the version it also displays the data for the revision and memory date gt K VERSION DISPLAY 038 00 DO0 COMPUTER 038 TO DO TELEC gt VERSION E DISPLAY 038 00 D0 5 REV OO DATE 27 01 2011 H v sa de IA E TD lhe ER 23 Q10 Tec rev 1106 The Setup entry displays the setup settings introduced during the Data Standard insertion phase Setup STANDARD DATA MO 1 GR 1 Capp Menu 1 Entering Standard Data Before performing this operation switch off the machine and position dipswitch 1 on display screen ON then switch on the machine If the procedure described above is not performed dip1 ON this message will appear on the display kkkkkkkkkkkkkkkkkk NEW SOFTWARE VERSION LOAD STANDARD DATA kkkkkkkkkkkkkkkkkk When inputting the Standard Data you are prompted to input data regarding model and type of machine CONFIGURATION STANDARD SELF 1 SELF 2 H 0 water from delivery spout YES NO TYPE coffee 1 Cappuccino PIPE type of pipe OFF disable AS turbosteam VAP steam H O water SPECIAL KEY YES NO PAY PER USE YES NO SOLUBLE 1 soluble 1 beverage YES NO SOLUBLE 2 soluble 2 beverage YES NO MENU different types of drinks
41. et zeros the error log Wash 1 Archive and malfunctions archive stored on the machine YES NO MAINTENANCE contains five entries to setting maintenance parameters Max cycles the number of cycles initially set 40 000 Max days the number of days initially set 185 N cycles the number of cycles remaining before the next maintenance session N days the number of days remaining before the next maintenance session Reset options are NO countdown of cycles and days remaining before the next maintenance session YES the settings for number of cycles 40 000 and remaining days 185 are reset OFF all controls for programmed maintenance are disabled and the N cycles and N days counters are zeroed PAY PER USE See paragraph Pay per Use on the following pages k CONFIGURATION HARDWARE SETUP TD ir BE ER HARDWARE SETUP parameters for cappuccino versions only includes 2 sub menus t start the activation time of the peristaltic pump at the beginning of the dispensing cycle which can be set from 00 1 to 20 0 seconds tinversion the activation time of the peristaltic pump at the end of the dispensing cycle which can be set from 00 1 to 20 0 seconds 6 Special keys Second selection SECOND SELECTION FUNCTION Permits a second type of beverage associated with the dispensing key to be dispensed This function can be obtained in this way access to Configuration Menu of the machine
42. etric dosage pulses from O to 999 with increments of 1 grinder MM grinder number 1 left 2 right MM coffee dose grinde encoder pulses 0 200 with increments of 1 start water determines if water is added at the beginning or end of coffee dispensing can be set before or after water add volumetric dosage pulses from O to 999 with increments of 1 heating mode acts on brewing temperature can be set from O to 4 See specific paragraph infusion infusion time 0 6 seconds with increments of 0 1 drying pod drying time 0 5 seconds with increments of 0 1 Start milk Start coffee function You can use the 30 and 31 keys to change the Start milk setting milk dispensing start delayed after coffee dispensing and vice versa from 00 to 99 with 1 second increments If over 99 is set the Start milk setting will become the Start coffee setting coffee dispensing start delayed after the milk dispensing then the setting returns to Start milk in a cycle Start Milk 00 A K 99 OS NN Start Coffee The default settings for cappuccino selections are Start milk 00 By setting Start milk 00 milk dispensing takes place when the selection key is pressed After a few seconds coffee is dispensed Start milk 99 or ata high setting that exceeds the coffee dispensing time milk dispensing starts after coffee is dispensed Start milk 05 coffee
43. eys to position the cursor on the ACCOUNTING line then press the PRG E 29 key The following will appear on the display akk ACCOUNTING COUNTERS MENU COUNTERS MENU Total 125348 n Sel O1 40254 Sel 02 32005 Sel 03 102581 Sel 04 9820 ca AP rs COUNTERS MENU A pM r Total 125348 H t Sel 01 40254 ENS TZ of i Sel 03 10258 u Sel 04 9820 ce ifr TE die os Pressing again the PRG 29 key on the display will appear the number of all dispensings performed and the number of dispensing for each selection key a rr Ce COUNTERS MENU n Sel O1 40254 Sel 02 32005 10258 9820 1 Note If the machine has no counting system the total number and numbers of the selections made are zeroed with the Counting and Director cards or with Dipswitch 4 in the ON position Sel 03 Sel 04 aa d r YL ip os 22 Q10 Tec rev 1106 13 DATA menu INFO DATA MENU COUNTERS MENU ACCOUNTING WASH ARCHIVE MALFUNCT ARCHIVE P v sia de 7 de dE de Serial number Use the 30 and 31 keys to position the cursor on Press the PRG 29 key on the serial n line The following will the INFO line then press the PRG 29 key The following will be appear on the display displayed SERIAL NUMBER 1234567 INFO ERIAL N VERSION SW SETUP DIP SETTINGS H TD ir 3 die E H v a de TE de dE XX Version The sub menu of the V
44. ger be the first to be dispensed but it will close the cycle The other beverages in the soluble combo do not change their dis pensing order Follow the same steps to modify the other beverages as preferred bvv Q10 Tec rev 1106 3 5 Key menu Hot water selection Press the hot water dispensing key 12 The following message will appear on the display KEY MENU Type water The following hot water selection parameters can be modified dispens time 20 0 type key personalizing e g water dosed water stop null dispensing time from 0 to 60 with increments of 0 1 seconds a ii UE Ar us 3 6 Key menu Steam selection Press the hot water dispensing key 13 The following message will KKEY MENU appear on the display Type IGAC y The following hot water selection parameters can be modified dispens time 20 0 type key personalizing e g steam dosed steam stop null dispensing time from O to 60 with increments of 0 1 seconds a d r YL Y gs 12 Q10 Tec rev 1106 4 TEST board During the view of the drinks by pushing the i 27 button on the display will appear the relevant drink parameters while the drink is delivered by the machine On the display will appear for example TEST F2 1 MM1 041 Dv F1 0 MM2 000 tG F3 O EN 130 P1 TB 09 The parameters displayed refer to F1 Middle limit switch 1 in position F2 High limit switch 1 in
45. he grinders Press RES 24 to return to panel M1 Legend 3 XXX defines the moving part that can be accessed 1 F1 Unit limit switch middle 0 1 Here is the table of symbols used to define the moving parts F2 Unit limit switch high 0 1 that can be accessed F3 Unit limit switch low 0 1 MR motor unit ratiomotor 1 limit switch in position Mav Coffee suction fan Ecv2 Not active Ech2 Not active 2 MC No coffee sensor 1 no coffee MMx2 Not active ML X No milk sensor 1 no milk Mds2 Soluble 2 dispenser motor M Grinder counter Echv Not active EN Group Encoder Echa Water soluble solenoid valve LIV Water level in boiler MMx Soluble mixer motore Bs Tray Mds Soluble 1 dispenser motor Dv Volumetric meter displays incremental count zeroed on Esc Service boiler water outlet solenoid valve entry of M1 menu El Cappuccino maker wash cycle solenoid valve RC Service Boiler resistance Ets Steam solenoid valve Re Grounds drawer Ear Air solenoid valve P Boiler pressure displayed in bar or psi Em Milk solenoid valve RB Boiler resistance Evc Boiler load solenoid valve Ti CPU temperature Eac Hot water solenoid valve TB Boiler temperature in C or F G Coffee dispensing solenoid valve MP Pump motor MM2 Grinder 2 motor MM1 Grinder 1 motor Mpl Milk pump motor Parts are applied only in some product configurations 20 Q10 Tec rev 1106 10 Weighting This menu permits the weighing of the ground coffee
46. he volumetric counter is malfun ctioning or is electrically discon nected The G solenoid valve is malfun ctioning or is electrically discon nected The pump is malfunctioning only in case of intake from reservoir The check valve filter is clogged The coffee group filters are clogged 068 The coffee group racks are unhooked The coffee grounds are too making the group unstable coarse the infusion time is too long or input group pressure is below 4 bar The group rack is malfunctioning The coffee group motor is mal functioning 070 Wrong data reading by RAM clock or by ls There is a card malfunction EEPROM 071 Dead clock buffer battery Replace the battery 098 Error log and washing log reset Initialization has begun for the er ror log and washing log structure 099 Default data loading 29 Q10 Tec rev 1106 18 Abnormal functioning machine and operator Coffee circuit DESCRIPTION POSSIBLE CAUSES SOLUTIONS The machine does not dispense the The nominal boiler temperature has not requested beverages been reached There is no coffee The coffee receptacles are closed or obstructed The group was not installed correctly The outlet tube from the group in the coffee dispenser nozzle was not installed correctly The coffee receptacle cannot bel Remove any coffee grounds on the top positioned correctly in the machine panel of the machine or in the upper part of the grind
47. lectrov lvulas los tubos hidr ulicos y los conectores el ctricos Antes de proceder desmontagem desconectar do grupo das electrov lvulas os tubos hidr ulicos e os conectores el ctricos Rimuovere la vite di fermo V Remove the fastening screws V Retirer la vis d arr t V Die Feststellschraube V l sen Desmontar el tornillo de fijaci n V Remover os parafusos de bloqueio V Estrarre la spina di bloccaggio S e rimuovere il gruppo elettrovalvole tirandolo verso l alto Remove the lock pin S and remove the solenoid valve group by pulling it upward Extraire la cheville de blocage S et ter le groupe de soupapes lectriques en le tirant vers le haut Den Sperrstift S herausziehen und die Einheit Magnetventile ausbauen indem sie nach oben hin herausgezogen wird Quitar la clavija de bloqueo S y desmontar el grupo electrov lvulas tirando de l hacia arriba Extrair a ficha de bloqueio S e remover o grupo das electrov lvulas puxando o para cima 44 Q10 Tec rev 1106 Rimozione assieme caldaia boiler Boiler heater assembly removal Retrait de l ensemble chaudiere chauffe eau Ausbau Einheit Wasserkessel Boiler Desmontaje del grupo caldera calentador Remoc o do conjunto caldeira boiler Prima di procedere con lo smontaggio scollegare tutti i tubi idraulici e i connettori elettrici collegati all assieme caldaia boiler NOTA la sonda temperatura T e collegata direttamente alla sche
48. luble 1 1 soluble 2 1 mix soluble 2 coffees 2 cappuccini 2 milks 2 solubles 1 2 solubles 2 2 mix solubles stop water null repetition it represents the number of distributions of the selected drink from 001 to 099 Milk dose milk dispensing time O 60 seconds with increments of 0 1 Emulsion foamed milk dispensing time from O to 60 with increments of 1 second HM FM this parameter lets you decide which type of milk frothed or regular to dispense first YES regular milk frothed milk NO frothed milk regular milk cold milk dose cold milk dose from O to 20 with increments of 0 1 seconds v Mpl cold milk cold milk pump motor speed from 10 to 5596 with increments of 1 v Mpl hot milk hot milk pump motor speed from 10 to 55 with increments of 1 Setting a value of less than 35 is recommended Milk temperature depends from this parameter low value high milk temperature high value ow milk temperature v Mpl milk HM hot hot regular milk pump motor speed from 1096 to 5596 with increments of 1 Setting a value of less than 3596 is recommended Milk choice between two types of milk if function is activated Q10 Tec rev 1106 3 2 Key menu Cappuccino selection Press one of the cappuccino dispensing keys 32 the relative led will remain on The following message will appear on the display KEY MENU repetition 001 Milk dose Coffee start
49. n SERVICE TIME e pressing the PRG 29 key The machine will restart with the messages provided in the selected language ENGLISH DEUTSCH The display 5 provides a choice of the following languages FRANCAIS Italian English German French Spanish Portuguese Dutch Japanese and Russian aa d r YL ip os 26 Q10 Tec rev 1106 Service time menu Pressing the PRG 29 the following message will appear on the display gt gt SERVICE TIME DATE AND TIME N ON time 03 00 OFF time 03 00 none g O2 00 Day off Night ON ipm d r YL die os The following service time parameters can be modified ON time time the machine switches on OFF time time the machine switches off day off day on which the enterprise is closed Night ON start time for evening beverage price only when payment system is connected Night OFF end time for evening beverage price only when payment system is connected Wash 1 request every 24 hrs at the programmed hour cannot be disabled Wash 2 5 hour of scheduled washes from 2 to 5 General indications If there is no day off i e the enterprise never closes enter none for the day off item Enter the same time for the ON time and OFF time parameters for example ON time 22 00 OFF time 22 00 if the automatic switch on switch off function is not required and you wish to manually switch the machine on and off WASH 1 AND WASHES 2
50. nd a maximum of 100 C 149 212 F temp I the temperature added to temperature it serves to guarantee a good quality of coffee right from the first coffee dispensed after a certain amount of time can be set between 0 and 10 C 32 50 F interval the minimum time that must pass between two dispensing sessions without increasing the boiler temperature setin temperature IIl can be set between 0 and 20 minutes CONFIGURATION 4 SOLUB PARAMETERS2 TURBOSTEAM MEASUREMENT UNITS N grounds ipn r TE YY ab SOLUBLE 1 2 PARAMETERS defines the mixer functioning time after the Gsol soluble solenoid valve has closed can be set between O and 5 with increments of 0 1 seconds Can be enabled in the soluble beverage recipes at the entry mixer delay 040 TURBOSTEAM emulsion level 4 levels can be chosen where 001 is less emulsion and 004 is continuous emulsion MEASURING UNIT includes 2 sub menus Temperature can be set to C Celsius centigrade or F Fahrenheit degrees Pressure can be set to bar or psi 14 N grounds refers to number of grounds from O external container to 80 gt K CONFIGURATION SOFTNER REGENER CHANGE W FILTER Customer prog NO YES NO 3 bean key prog lock Ra we TE die os SOFTNER REGENERATION includes the parameters for the softner regeneration liters of resin da 0 11 a 251 hardness da O a 45 F CHANGE WATER FILTER When the programm
51. nectores el ctricos conectados ao conjunto das bombas Svitare le 3 viti di fissaggio indicate in figura e rimuovere l assieme pompe Unscrew the 3 fastening screws indicated in the figure and remove the pump assembly D visser les 3 vis de fixation indiqu es dans la figure et retirer l ensemble pompes Die 3 in der Abbildung gezeigten Schrauben l sen und die Pumpeneinheit herausnehmen Destornillar los 3 tornillos de fijaci n indicados en la figura y desmontar el grupo bombas Desaparafusar os 3 parafusos de fixac o indicados na figura e remover o conjunto das bombas 46 Q10 Tec rev 1106 Regolazione contrasto display Display contrast setting Reglage du contraste du display Einstellung des kontrasts der Display Regulaci n del contraste del display Reglage do contraste do display 47 Agire sul trimmer D posto sulla scheda elettronica affinche sul display si leggano i messaggi in modo chiaro Adjust trimmer D located on the electronic card until the messages may be clearly read on the display Agir sur le trimmer D plac sur la fiche lectronique afin de pouvoir lire clairement les messages qui apparaissent sur le display Stellen Sie den auf der Elektronikkarte installierten Reger D so ein da die Meldungen auf der Anzeige in gutem Kontrast abgebildet werden und gut abgelesen werden k nnen Utilizar el trimmer D situado en la tarjeta electr nica para que se lean los mensajes claramente en el visualiz
52. ngegebenen Befestigungsschrauben l sen Destornillar los tornillos de fijaci n indicados en la figura Desaparafusar os parafusos de fixac o indicados na figura Rimuovere la copertura del pannello posteriore R Remove the cover to the rear panel R Retirer la couverture du panneau post rieur R Die Abdeckung des r ckseitigen Paneels R abnehmen Desmontar la cubierta del panel posterior R Remover a cobertura do painel posterior R 42 Q10 Tec rev 1106 Riarmo termostati Thermostat reset R armement des thermostats R cksetzung Thermostate Rearme de los termostatos Rearme dos term statos In caso di intervento del termostato riarmare In case of thermostat intervention switch on again En cas d intervention du thermostat brancher de nouveau Falls der Thermostat ausgel st wird ihn wiederienschalten En caso de intervenci n del thermostato reencender de nuevo En caso de incarvenc o do termostato reacender de novo Rimozione assieme ingresso acqua Water inlet assembly removal Retrait de l ensemble de l entr e de l eau Ausbau der Einheit Wassereinlauf Desmontaje del grupo de entrada agua Remoc o do conjunto da entrada da gua Rimuovere l assieme ingresso acqua W tirandolo verso l alto Nota l estrazione del filtro F pu avvenire anche senza lo smontaggio dell assieme ingresso acqua W Remove the water inlet assembly W by pulling it upward Note the filter F can be r
53. nt down will start again from 30 seconds before the end of the dispensing cycle e if the milk cappuccino dispensing key is pressed the timer count down will start from the set up time 210 e If the 28 key is pressed the automatic wash cycle will be 17 Q10 Tec rev 1106 8 Pay per Use This function makes it possible to control the beverages made with To enable the count perform a reset RESET YES the entry N ground coffee It is activated when a personal numeric code composed select is the same number as the MAX select entry of 4 numbers is inserted during the initialization phase with standard machine data gt PAY PER USE A After the function is activated you must access the PAY FOR USE MAA select S919199 y parameter in the configuration menu Insert your personal code on the N select 20000 line with the asterisks and insert the maximum number of dispensed RER beverages at the entry MAX select Reset NO RECHARGE ARCHIVE Ka d ie A E gt PAY PER USE 4 MAX select PXO q N select OOOOO eX From this moment on after each coffee beverage dispensed the Reset NO number associated with the N select entry is decreased by 1 unit RECHARGE ARCHIVE v for a single coffee and 2 units for a double coffee bit E 4 When the number 250 is reached after each beverage dispensed the ein 1 6 d cb display screen shows the remaining number of beverages before
54. or black line to the entry to be modified then press the PRG 29 key The cursor will turn into an arrow T and it becomes possible to change the number for the selected entry by using the 30 and 31 keys Once the operation is completed press the RES 24 key to confirm the data Note the cursor changes back to black line Repeat the operation described above to modify other parameters Q10 Tec rev 1106 17 Defects Malfunctions 1 2 MALFUN Code DESCRIPTION POSSIBLE CAUSES SOLUTIONS 002 Coffee group piston descent timeout during The motor group is malfunctioning the repositioning phase after one minute in e There is a foreign body inside the the grinding position chamber The tray has been removed The coffee grounds drawer has been removed 003 he coffee group piston did not reach the e The coffee group is malfunctioning dispensing zone but the compression The ground coffee dose is more ensor has intervened than maximum amount allowed There is a foreign body inside the chamber 007 The coffee group piston has reached the The fastening screw is loose and dispensing zone but the positioning timeout the group is being pulled in an has intervened because the compression abnormal way by the motor crank sensor and the limit switch sensor did note The compression sensor is commute malfunctioning The limit switch signal is lost 008 The coffee group does not move The coffee group motor is
55. parar la tolva de caf de la m quina Com a ajuda de uma ferramenta rodear para a esquerda o dispositivo de fixac o F e separar a tremonha do caf da m quina Q10 Tec rev 1106 Rimozione tramogge solubili Solubles receptacle removal Retrait des tr mies de solubles Ausbau Trichter l sliche Produkte Desmontaje de las tolvas de los productos solubles Remoc o das tremonhas dos sol veis chiuso closed ferm geschlossen cerrado fechado Spingere il dispositivo di chiusura tramoggia Hs verso il retro della macchina Push the hopper closing device Hs towards the back of the machine Pousser le dispositif de fermeture de tr mie Hs vers l arri re de la machine Cs Schieben Sie den Trichterverschlu 3 Hs nach hinten Empujar el dispositivo de cierre de la tolva Hs hacia la parte posterior de la m quina Empurrar o dispositivo de fecho da tremonha Hs em direcc o da parte traseira da m quina Con l ausilio di un utensile ruotare in senso antiorario il dispositivo di fissaggio Fs Use a tool to turn the fastening device Fs counter clockwise Au moyen d un ustensile tourner le dispositif de serrage Fs dans le sens contraire des aiguilles d une montre Drehen Sie die Vorrichtung zur Trichterbefestigung Fs mit einem geeigneten Werkzeug gegen den Uhrzeigersinn Con la ayuda de una herramienta girar en sentido contrario a las agujas del reloj el dispositivo de fijaci n Fs
56. position F3 Low limit switch 1 in position MM coffee extraction impulses EN group encoder Dv Volumetric meter impulses tG Dispensing time in seconds P boiler pressure 13 Q10 Tec rev 1106 5 Configuration menu gt K CONFIGURATION SPECIAL KEY SPECIAL KEYS Boiler P 1 6bar level sensib 2 TD dde H dde 2 RS SPECIAL KEY KEY 25 in the bottom right hand corner of the selection keypad YES NO YES the key can be set with one of the functions described in SPECIAL KEYS NO it is set like all the other dispensing keys The standard data for the special key is NO SPECIAL KEYS The key 25 can be personalized with one of the following functions disable disables key Stop stop the dispensing Il choice second function dispensing of a second beverage See paragraph Special keys Second selection on the following pages water stop stop the water dispensing Normally the special key is Disabled Boiler P indicates the service boiler pressure 0 6 1 7 bar 9 23 psi Level sensib Water Level sensitivity it indicates the level sensitivity of the boiler water probe The setting range is from 1 to 3 the value 3 indicates the hightest probe sensitivity and therefore the machine will refilles the boiler at the minimum water level variation BOILER The parameter includes 3 sub menus temp coffee boiler operating temperature can be set between a minimum of 65 a
57. rect The EL solenoid valve is malfunctioning or disconnected There are water residues in the washing The inversion setting is incorrect circuits after dispensing The EL solenoid valve is malfunctioning or disconnected There is a combination of water steam There is no water in the washing tray in the cup at the start of the dispensing The milk intake tube is clogged blocked cycle 18 Abnormal functioning machine and operator Washing DESCRIPTION POSSIBLE CAUSES SOLUTIONS After the washing sequence starts the The steam boiler or water boiler has not machine remains in standby for almost a reached the correct temperature pressure minute Il lavaggio caff dura pi del normale The coffee filters may be clogged Fuoriuscita di vapore dal montalatte Esaurimento acqua contenuto nella ed immissione di vapore all interno del vaschetta di lavaggio frigorifero e tubo di aspirazione latte ostruito occluso 31 Q10 Tec rev 1106 18 Abnormal functioning machine and operator Components DESCRIPTION POSSIBLE CAUSES SOLUTIONS There is dampness in the receptacles or The steam intake fan is malfunctioning inside the front panel The back or front doors not closed properly The coffee grounds drawer has water The grinder settings for the coffee dose are inside incorrect The drying temperature is too low The top piston OR is worn The coffee grounds drawer has grounds
58. requested daily at the In case of lack of washing operations they will be recorded in the error programmed hour and within 24 hours ARCHIVE i 27 button as PARTIALS washing WASH 2 3 4 and 5 can be disabled and set to OFF Preset automatic washing cycle NSF no settable Function after each milk cycle has terminated the timer count down performed immediately starts max 210 At the end AUTOMATIC WASHING appears on l i i ds j Selection block always inactive The wash cycle is performed even the display with the time remaining before the wash cycle begins if the user does not intervene 10 March 2010 Wash type with milk or water completely automatic wednesday 15 15 04 u Special conditions 1 with each washing cycle with detergent at a preset time or daily washing cycle In this case the entire circuit is washed Therefore during the first milk dispensing procedure the circuit is considered free of residual milk and the timer 210 countdown is not launched 2 eachtime the machine is switched off while the timer countdown 210 is underway when the machine is switched on again if 210 have passed once the machine reaches its operating temperature the preset automatic washing cycle is launched and cannot be stopped AUTOMATIC VVASHING Activation activation is automatic at the end of the remaining 30 seconds During this stand by time e if the coffee dispensing key is pressed the timer cou
59. s de realizar el desmontaje desconectar del grupo caf los tubos hidraulicos y los conectores el ctricos situados respectivamente en los puntos 1 y 2 de la figura que est al lado Para facilitar o reposicionamento do grupo caf acender a m quina e premir a tecla sleep mode 5 SM aguardar alguns segundos e seguidamente voltar a desligar a m quina Antes de proceder desmontagem desconectar do grupo caf os tubos hidr ulicos e os conectores el ctricos posicionados respectivamente nos pontos 1 e 2 da figura ao lado Rimuovere la copertura G del gruppo Remove the cover G on the group Retirer la couverture G du groupe Die Abdeckung G der Kaffeeabgabeeinheit abnehmen Quitar la cubierta G del grupo Remover a cobertura G do grupo Svitare la vite di fissaggio F ed estrarre il gruppo Unscrew the fastening screws F and remove the group D visser la vis de fixation F et extraire le groupe Die Schraube F l sen und die Einheit herausnehmen Destornillar el tornillo de fijaci n F y desmontar el grupo Desaparafusar o parafuso de fixac o F e extrair o grupo 37 Q10 Tec rev 1106 Riposizionamento gruppo caffe Coffee group repositioning Repositionnement du groupe de caf Erneuter Einbau der Kaffeeabgabeeinheit Montaje del grupo caf Reposicionamento do grupo caf Qualora la manovella motore M non si trovasse nella corretta posizione figura B accendere la macchin
60. sto sleep mode 5 SM attendere qualche secondo quindi rispegnere la macchina Prima di procedere con lo smontaggio scollegare dal gruppo caffe i tubi idraulici e i connettori elettrici posizionati rispettivamente nei punti 1 e 2 della figura a lato To make iteasier to reposition the coffee group switch on the machine and press the Sleep Mode key SM Wait a few seconds and then switch off the machine Before removal disconnect the water tubes and electric connectors from the coffee group positioned respectively at points 1 and 2 in the figure opposite Pour faciliter le repositionnement du groupe de caf mettre la machine en marche et appuyer sur la touche sleep mode SM attendre quelques secondes puis teindre a nouveau la machine Avant de proc der au montage d brancher du groupe de caf les tuyaux hydrauliques et les prises lectriques plac s respectivement aux points 1 et 2 de la figure ci contre Zur Vereinfachung des erneuten Einbaus der Kaffeeabgabeeinheit die Maschine einschalten und die Taste sleep mode SM drticken einige Sekunden abwarten und die Maschine erneut ausschalten Vor dem Ausbau die Wasserleitungen und die elektrischen Steckverbinder siehe Punkte 1 und 2 u der seitl Abb von der Kaffeeabgabeeinheit abziehen Para facilitar la instalaci n del grupo caf encender la m quina y presionar la tecla sleep mode SM esperar unos segundos y luego apagar la maquina Ante
61. the coffee based beverages selection is blocked Beverages not made with ground coffee can still be dispensed The number of dispensed beverages can be set between 0 and 65 000 with increments of 10 To enable coffee based selections again you must recharge using the same method described above Each operation of this type is stored in the Recharge archive entry 18 Q10 Tec rev 1106 9 Test menu MANUAL CONTROLS permit parts to be manually operated using a 215 COMMANDS A 72 30 and Y 31 keys see paragraph Manual control TD dp BE ER Manual control panel Press the PRG 29 key on the MANUAL COMMANDS line the following panel will appear on the display Panel 1 MC11 MC21 ML 1 000 M2 000 EN 000 OK F1 1 Bs 0 OFF F2 1 DV 0000 OFF F3 1 Rc 1 7bar130 6RB ON 018 8C TB 089 6 C gt PRG gt X X X RES Press 30 or 31 to display the various component Press PRG 29 to select the component to move and to switch to the next panel M2 Press RES Q 24 to quit manual mode Q10 Tec rev 1106 Panel 2 MC10 MC20 MLO M1 000 M2 000 EN 000 IV OK F 1 Bs U Evc OFF F2 DV 0000 RC OFF F3 R c 1 P bar130 6RB O N T 018 8 C TB 089 6 C t gt XXX OFF Press 30 or 31 to activate the components if they have a direction use 30 and 31 to alternate the activations Lh Rh or Up Down Widen Narrow t
62. tirer le groupe des moulins Die in der Abbildung angegebenen Befestigungsschrauben l sen und das Mahlwerk abnehmen Destornillar los tornillos de fijaci n indicados en la figura y desmontar el grupo molinillos Desaparafusar os parafusos de fixac o indicados na figura e remover o grupo moinhos Q10 Tec rev 1106 Apertura pannello posteriore Opening the rear panel Ouverture du panneau sup rieur Offnen r ckseitiges Paneel Apertura del panel posterior Abertura do painel posterior Rimuovere le 2 viti Q situate nella parte posteriore della macchina e aprire il pannello Remove the 2 screws Q at the back of the machine and open the panel Retirer les 2 vis Q situ es dans la partie post rieure de la machine et ouvrir le panneau Die beiden Schrauben Q auf der R ckseite der Maschine l sen und das Paneel ffnen Desmontar los 2 tornillos Q situados en la parte posterior de la m quina y abrir el panel Remover os 2 parafusos Q situados na parte posterior da m quina e abrir o painel Rimozione copertura pannello posteriore Rear panel cover removal Retrait de la couverture du panneau post rieur Ausbau Abdeckung r ckseitiges Paneel Desmontaje de la cubierta del panel posterior Remoc o da cobertura do painel posterior Svitare le viti di fissaggio indicate in figura Unscrew the fastening screws indicated in the figure D visser les vis de fixation indiqu es sur la figure Die in der Abbildung a
63. to OFF again ATTENTION Le changement de position des Dip Switch doit tre RIGOUREUSEMENT effectu lorsque la machine est ETEINTE En phase de standard les Dip Switch sont pla s sur OFF Utiliser les Dip Switch O pour activer les fonctions suivante DIP 1 OFF ON introduction informations standard DIP 2 OFF DIP 3 OFF ON simulation clef technique DIP 4 OFF ON comptabilit DIP 5 OFF ON habilite la s quence de touches pour entrer en programmation DIP 6 OFF DIP 7 OFF DIP 8 OFF la fin des op rations d introduction des informations standard remettre le DIP 1 sur la position OFF 48 ACHTUNG Die Verstellung der Dip Switch Schalter darf nur bei ABGESCHALTETER Maschine vorgenommen werden Bei normalen Betriebsbedingungen m ssen die Dip Switch Schalter auf OFF gestellt sein Nachstehend werden die Funktionen bei entsprechender Einstellung der Dip Switch Schalter O aufgef hrt DIP 1 OFF ON Eingabe Standarddaten DIP 2 OFF DIP 3 OFF ON Simulation Monteurschl ssel DIP 4 OFF ON Buchf hrung DIP 5 OFF ON ermachtigen Sie die Anschlagsequenz um in Programmierung hineinzugehen DIP 6 OFF DIP 7 OFF DIP 8 OFF Nach Abschlu der Eingabe der Standarddaten mu der Dip Switch Schalter 1 auf OFF zur ckgestellt werden ATENCI N El cambio de posici n de los Dip switch O se tiene que efec tuar RIGUROSAMENTE
64. ts of 0 1 mixer pre dose the mixer starts before the Gsol soluble solenoid valve can be set between 0 0 and 10 0 with increments of 0 1 seconds pre dose dispenser the dispenser starts before the mixer can be set between 0 and 10 seconds with increments of 0 1 dispenser delay the dispenser starts after the mixer can be set between 0 0 and 5 0 with increments of 0 1 seconds dispenser type dispenser mode chosen between two soluble powder dispensing modes continuous powder is continuously dispensed for a time equal to the one set at the entry t tot disp step powder is dispensed at intervals where the entry t on disp indicates the powder dispensing phase and the entry t off disp indicates the standby phase tot time dispenser total dispenser time between O and 30 sec onds with increments of 0 1 this is the dispenser dispensing time corresponding to the total time the dispenser is activated in continu ous mode t ON dispenser dispenser activation time between O and 5 sec onds with increments of 0 1 the parameter is only visible in the step mode t OFF dispenser dispenser deactivated time between O and 5 seconds with increments of 0 1 the parameter is only visible in the step mode step H20 the Gsol soluble solenoid valve hydraulic circuit is acti vated in steps to modulate the water dose between 50 and 100 with increments of 10 H20 delay dispensing time of just water st
65. wash is changed Setting autom washing OFF e timed automatic wash cycle is disabled e when the button 28 is pressed the milk circuit washing cycle is performed Setting autom washing 3 99 e the timed automatic wash cycle is activated and the set time interval starts when the button 28 G i is pressed the milk circuit washing cycle is performed The cycle starts automatically The time interval is set between 3 and 99 minutes The timer starts at the end of each milk dispensing phase When the time runs out the automatic wash cycle begins 16 30 before the timer stops the LEDs on the keys of beverages with milk start blinking The display appears as follows 10 March 2010 wednesday 15 15 04 AUTOMATIC WASHING 28 aa SU YL ie s Ok During this standby phase Ifthe coffee dispensing key is pressed the counter will start again 30 from the end of the dispensing cycle per use If a milk cappuccino key is pressed the counter will start again from the set time 3 99 If the key 28 Gei is pressed the automatic washing cycle will be immediately performed Q10 Tec rev 1106 Washing options Solubles washing Includes 2 sub menus wash solub soluble wash cycle the time in minutes after which the request appears for the soluble beverage wash cycle Can be set between 1 and 20 minutes with increments of 1 minute or set to OFF wash request disabled At the end of each
66. y The following will be displayed X DATA MENU ACCOUNTING INFO N milk number of milk beverages Soluble 1 number of soluble 1 beverages Soluble 2 number of soluble 2 beverages N water number of times water is dispensed N steam number of times steam is dispensed using the turbosteam function N steam air number of times steam and air are dispensed using the turbosteam function N tot coffee total number of coffee beverages N cycles total number of cycles performed MM1 number of grinding phases performed by the 1 grinder MM2 number of grinding phases performed by the 2 grinder WASH ARCHIVE MALFUNCT ARCHIVE Ka die vr wu os XN Use the 30 and 31 keys to position the cursor on the COUNTER line then press the PRG O 29 key The following will appear on the display Counters can be zeroed by aligning the cursor on the selected entry pressing the PRG 29 key and then pressing the 30 or gt 31 key K COUNTERS MENU AR coffee 25 H Note Parameters that cannot be zeroed are N milk 15 N tot coffee N solub 1 12 N cycles N solub 2 10 N water 10 E G we TE die os 12 DATA menu ACCOUNTING Placing the cursor on the various selections the led associated to the K DATA MENU key remains ignited COUNTERS MENU i INFO WASH ARCHIVE MALFUNCT ARCHIVE TD Air vr dr 2 xS Use the 30 and 31 k