Home
view manual - Amcon Labs
Contents
1. B ae AMCON HAND EDGER USER S MANUAL EQ 3002 AMCON RETF 1 800 255 6161e Fax 1 800 397 0013 AMC The Eyecare Supply CE NTER DISC IAIN GR sscecesa2d veccapviteecectiiceedtateninacscdeenevstedenteoceeneaseenactanieeeeeeeies 3 We MUEOGUICUION 2865 te nce pacgect ae acento ee caeeec tee eh ceed tte ieeaet 4 2 Safety PRECAUTIONS sooucsac arco eek ceed cae 5 3 Unpacking The Machine ssseeeeeeeeeeeeeeeeeeeeeeeeees 6 Abs PAINS soe cos suakes Saeed atec eect A TE 7 5 Preparing The Machine For Operation sssssssseeseeeee 8 6 Maintenance aaasannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn 9 AMCON Birr Amcon Hand Edger Disclaimer Amcon The Eyecare Supply Center makes no representations or warranties either expressed or implied with respect to the contents hereof and specifically disclaims any warranties merchantability or fitness for any particular purpose Further Amcon The Eyecare Supply Center reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of this company to notify any person of such revision or changes AMCON Birr Amcon Hand Edger 1 Introduction Thank you for purchasing the Amcon Hand Edger The Amcon Hand Edger quickly and easily pin bevels edged lenses for mounting Please read these instructions and keep this manual in a convenient location for future
2. not touch the wheel while the machine is in operation to avoid injury Do not use replacement parts from sources other than the manufacturer If other replacement parts are used all warranties will be null and void AMCON Birr Amcon Hand Edger 3 Unpacking The Machine 1 Open the carton and take out the machine wrapped in foam 2 Carefully remove the machine from the foam packing 3 Place the machine on a stable flat surface 4 Make sure the following accessories are included in the package Upper Water Can Hose Plastic Belt Water Tray in underside of the machine Honing Stick AMCON St Amcon Hand Edger 4 Parts Upper water can Water valve Sponge Water blocking Diamond grinding wheel plate Chief power switch Water Tray in the underside Fig 1 Exhaust hole ANNCON Geer Amcon Hand Edger 5 Preparing The Machine For Operation 1 Remove the water tray from the under side of the machine 2 Remove the Phillips head screw from the drain 3 Connect the hose supplied to the drain 4 Replace the water tray in the underside of the machine 5 Sit the machine on the table and run the hose into a bucket or reservoir 6 Place the upper water can in the trough on the top of the machine and fill with clean water When the machine is used for the first time take the sponge out from under the water valve and moisten it and put it back in place 7 Open the water
3. reference WARNING Never attempt to operate this machine before you have thoroughly read and understood all the instructions Failure to comply can result in fire electric shock or serious personal injury Keep this users manual on hand and review frequently to ensure continued safe operation NOTE Manufacturer assumes no responsibility or liability for any damages caused by negligence or ignorance or precautions in this manual AM The Eyecare Supply CE ENTER Amcon Hand Edger 2 Safety Precautions To ensure safe use of this product it is important that you follow the instructions outlined in this manual and marked on the product Please read this user s manual before you operate your hand edger Save this user s manual for future reference Do not use this machine for any purpose other than hand edging lenses Make sure your power source corresponds to the specifications of the unit Never operate this machine with the wrong power source Do not place the machine in a hot area or near flammable materials If any type of liquid or material gets into the inner part of the unit IMMEDIATELY turn off and unplug the unit Until a qualified service representative checks the unit do not turn the power back on Do not try to disassemble any part of the unit except the parts that are explained in this manual Doing so will void all warranties Unplug the power cord when not in use for a long period of time Do
4. valve and let the water drip at 80 100 drops a minute Turn on the Switch and the machine is ready to be used Note The right side of the wheel is rough the left side is fine AMCON Birr Amcon Hand Edger 6 Maintenance 1 Remove cover by removing the two screws on top under the upper water can 2 Take belt off 3 Remove the right shaft mount by unscrewing the screws under the belt with a 10 mm wrench 4 With a 1 wrench loosen the mounting screw on the left side of the wheel 5 Slide the wheel off the shaft and replace with new or retrued wheel 6 Tighten mounting screw 7 Replace shaft mount and screws 8 Replace cover and cover screws Note The grinding wheel can be honed when needed
Download Pdf Manuals
Related Search
Related Contents
CAHIER DES CLAUSES TECHNIQUES PARTICULIERES Manual - iProcesSmart.com Netgear XAVB5004 Copyright © All rights reserved.
Failed to retrieve file