Home

ZS User Manual - Intelligent Weighing Technology, Inc.

image

Contents

1. Model Capacity Division ZS 600 600g 1lb 5 1950z 0 19 0 0050z ZS 3000 3000g 6lb 9 980z 0 5g 0 020z ZS 6000 6000g 13 4lb 000z 1g 0 050z P Mus 9V battery or External Power Adaptor Source Max Zero 2 of Rated i o apaci Range Nee Max Ti E 100 of Rated capacity Subtractive Range Weight Units Note Metric g Avoirdupois Ib amp oz amp Taiwanese tg A Operation 8 0 40 C 32 104 F Non condensed R H x 85 Environment Specifications subject to change without notice NOTE A To comply with the law of certain countries Avoirdupois and Taiwanese weight units may be disabled Contact your dealer for more information KEYBOARD LAYOUT amp FUNCTIONS 99 UWE Tid OFF innnnps foo or ALLE gt CJE ZS SERIES PERO WOO 66 OFF KEY Press this key to turn scale off 2 ON ZERO KEY Press this key to turn scale on or set weight to zero 3 TARE KEY Press this key to tare off the weight of a container 4 MODE KEY Press this key to switch between weight units KEYBOARD LAYOUT amp FUNCTIONS ZERO INDICATOR This indicator appears to indicate zero weight status MINUS INDICATOR This indicator appears to indicate negative weight values LO BAT INDICATOR When this indicator appears change the battery WEIGHT INDICATOR Displays the weight of the item placed on the scale 9 NET INDICATOR This indicator
2. Ib oz and Taiwanese with or without backlight if required Refer to page 8 for internal setting procedures For backlight just keep pressing the mode until the display is backlit The weight unit used before power off will be employed when the scale is turned on again Set Display Value to Zero when Unloaded Press ON ZERO to set weight displayed to zero when unloaded Refer to SPECIFICATIONS for maximum zero range Tare off the Weight of a Container When a container is used follow the steps below to tare off the weight of it and to obtain a net weight result Remove all loads away from platter b Make sure that zero weight and the ZERO INDICATOR appear If not press ON ZERO to set it to zero weight c Place the container on the platter Press TARE 12 INSTRUCTION FOR USE After TARE is pressed the NET INDICATOR and then a zero weight value are displayed In this case the ZERO INDICATOR will not appear even though a zero weight is displayed Refer to page 11 for weighing procedures Weight displayed is the net weight of the subject matter Refer to SPECIFICATIONS for maximum tare range Clear the Tare Function Remove all loads from platter The scale will display a negative value which is the weight of the container and the ZERO INDICATOR appears Press TARE After TARE is pressed a zero weight will be displayed while the ZERO INDICATOR remains 13 INSTRUCTION FOR USE Lo Bat Indicator When
3. appears to indicate the tare function is in operation and weight shown is net weight METRIC INDICATOR This indicator appears to indicate the metric weight unit is in use 1 AVOIRDUPOIS UNITS INDICATOR This indicator appears to indicate the avoirdupois weight unit is in use INTERNAL FUNCTIONS The scale is equipped with 13 internal functions which are NUMBER FUNCTION DESCRIPTION Fun 0 For Qualified Technical Personnel Only Fun 1 For Qualified Technical Personnel Only Fun 2 Check Display Segment Fun 3 Select Auxiliary Weight Units and offset value Fun 4 Select Auto Power Off Fun 5 Select Rs 232 Baud Rate amp Protocol Fun 6 Select Digital Motion Filtering Function Fun 7 Select Serial Output Mode Fun 8 Select UTP Printout Format This function is UTP related Fun 9 Select Auto Tare Function Fun 12 Select Number Of Printout Copy This function is UTP related Fun 15 Set and Send Date amp Time Data to UTP This function is UTP related Fun 19 For Qualified Technical Personnel Only Only installed with RS232 option 6 INTERNAL FUNCTIONS Do not alter any parameters set in Fun 0 1 amp 19 which may cause system instability error or non accurate weighing result If entered by mistake press OFF immediately Contact your dealer for more information INITIAL SETUP How to select internal functions a Turn scale off b Press and hold TARE the
4. exacting results Value From bench scales to analytical balances weighing equipment priced for real world business applications with superior service and support Experience Expert advice to help you choose just the right product for your application Quality Value Experience it adds up to the Intelligent Investment e w Intelligent Weighing Technology Inc intelligent www intelligentwt com Weighing Technology Intelligent Weighing Technology Inc All rights reserved worldwide The information contained herein is the property of Intelligent Weighing Technology Inc and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permission The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodies 18
5. the LO BAT INDICATOR appears it means that the battery is power is low Replace the battery with a new one or apply the external power adaptor immediately The power adaptor jack is inside the battery compartment Caution When the power adaptor is being used remove all batteries from the battery pack Failure to do so may cause battery leak explosion or damages to the scale 14 ERROR CODES TROUBLESHOOTING Error Codes Error Code Description Nostbl Calibration weight is not stable Err 1 IC U2 93C46 failure Err 2 Offset Value too low Err 3 Offset Value too high Troubleshooting Syndrome Check Action Check Action Syndrome Check Action Scale cannot be turned on Is the scale power supply or battery power too low Replace the battery with a new one or apply the power adaptor Is the power adaptor inserted properly into both the electricity outlet and the DC inlet of scale Secure both ends of the power adaptor and try again Scale displays Err Is the load applied exceeding the rated capacity of scale Remove all loads from platter and try again 15 ERROR CODES TROUBLESHOOTING Syndrome Check Action Syndrome Check Action Check Action Check Action Check Action Scale turned off automatically Is the AUTO POWER OFF FUNCTION being employed Refer to page 9 in the Select Auto Power Off Function to disable the Auto Power
6. Intelligent Weighing Technology Inc ZS Series ELECTRONIC WEIGHING SCALE OPERATION MANUAL A Higher Level of Precision A higher Level of Performance INDEX Installation 2 Specifications 3 Keyboard Layout amp Functions 4 Internal Functions 6 Initial Setup 8 Instructions for Use 11 Error Codes Troubleshooting 15 Daily Care amp Maintenance 17 Intelligent Weighing Technology Inc All rights reserved worldwide INSTALLATION 1 Check and make sure that the following accessories are included Operation Manual X 1 ZS Scale X 1 Stainless Steel Platter X 1 Power Adaptor X 1 Contact your dealer if any item is missing 2 Install stainless steel platter 3 Power up the scale Insert one 9V battery not supplied into the battery compartment or apply the external power adaptor The power adaptor jack is inside the battery compartment Before plugging the power adaptor into the electricity outlet check and make sure the input voltage of the power adaptor matches with the output voltage of the outlet If they do not match please do not plug in the adaptor and contact your dealer for a replacement When the power adaptor is being used please remove all the batteries from the battery compartment Failure to do so might cause a battery leak explosion or damage to the scale Do not use any rechargeable battery This scale does not recharge any batteries 2 SPECIFICATIONS
7. Off Function Is the LO BAT INDICATOR on Replace the battery with a new one or apply the power adaptor immediately Weighing result is not accurate Is the scale placed in a level condition Relocate the scale to obtain a level condition Is the scale affected by airflow vibration or RFI Place the scale away from all disturbances Is the scale calibrated correctly Contact your dealer Is the correct weight unit employed Refer to page 12 to select the correct weight unit 16 DAILY CARE amp MAINTENANCE 1 Clean the scale with a soft and damp cloth If necessary apply a mild detergent Do not allow water anywhere near the scale Do not use any harsh abrasive material acetone volatile solvent thinner or alcohol for cleaning Verify the accuracy of scale periodically Re calibrate the scale if necessary Remove weights from the platter when not in use Remove the battery when the scale will not be used for an extended period www intelligentwt com 17 Intelligent Weighing Technology has more than 50 years combined experience in the weighing industry both in the USA and worldwide With contacts in over 50 countries including the USA we provide you with the weighing equipment you need When you invest in weighing equipment from Intelligent Weighing Technology you re really buying peace of mind Quality Scales and balances solidly built from the ground up with superior engineering and components for
8. ll turn off automatically when it is left idle for the selected time INITIAL SETUP Select Digital Motion Filtering Function 3 parameters are available Filt O filtering function disable Filt 1 filter 1 Filt 2 filter 2 Use digital motion filtering function when the operating environment is subject to disturbances like vibration wind flow etc Select higher filter values for worse environments Filt2 gives the slowest response compared with other 2 parameters Select Auto Tare Function 2 parameters are available Tr On Auto Tare Function enable Tr OFF Auto Tare Function disable Under the Auto Tare Function the first load applied to scale will be treated as a container and will be tared off automatically 10 INSTRUCTION FOR USE Before Weighing Make sure that 1 Weighing 1 The scale is placed on a level and stable surface The stainless steel platter is placed correctly on top of load receptor The scale is turned on The ZERO INDICATOR is on If not press ON ZERO to set display to zero Always place an object onto the platter gently Excessive force applied to platter may cause damage to the sensor inside the scale The weight of the object will be displayed automatically It is a good practice to remove all loads from platter after weighing It will prolong the life of the scale 11 INSTRUCTION FOR USE Selecting Weight Unit Press MODE to shift among various weight units gram
9. n press ON ZERO c Scale displays Fun 0 d Press TARE until scale displays the desired internal function number e Press MODE to enter and trigger various setting values f Press TARE to select g Scale displays the next internal function h Repeat d amp e for next desired setting or i Press TARE to save and restart scale or j Press OFF to save without restarting k Pres ON to restart scale Display Segment Check Under this function backlight if equipped functional indicators and display segments will be lit up Contact your dealer if any display element is missing Select Auxiliary Weight Units 2 auxiliary weight units in addition to metric are available These are Avoirdupois and Taiwanese Units Under this function scale displays capacity and division followed by the selected weight unit on Weight Panel INITIAL SETUP The example below 600 1 is the capacity and division of ZS 600 600g x 0 19 which is used for illustration 600 1 g metric only 600 1 g Ib oz metric and Avoirdupois weight unit enable 6 0 0 1 g Ib oz metric Avoirdupois and Taiwanese weight units all enable Select Auto Power Off Function 5 parameters are available OoFF Auto Power Off Function disabled 4oFF Auto off when left idle for 4 min 100FF Auto off when left idle for 10 min 200FF Auto off when left idle for 20 min 300FF Auto off when left idle for 30 min Under the Auto Power Off function mode the scale wi