Home
Easy-Switch GSM Temperature Alert and Monitoring System USER
Contents
1. 23 N When Setting as Security Mode 23 1 Mode switch lt ON gt 2013 10 10 17 13 Thu When Setting as Open Mode 23 0 Mode switch lt OFF gt 2013 10 10 17 13 Thu N 1 means in security mode Only allow the number in the list can text to the unit to control the system N 0 means in open mode Anybody can call to the unit to control the system Please take note that the Privacy and Security before you decide to use the Open Mode Factory Default is N 1 for Security Mode Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 20 SMS Text Message to Switch On Off 24 N When Setting as 24 1 N 1 means switch on the relay Relay Master relay lt ON gt by SMS Message N 0 means switch off the relay 2013 10 10 17 13 Thu by SMS Message When Setting as 24 0 Master relay lt OFF gt 2013 10 10 17 13 Thu 21 Edit Input Messages for the system 26 N XXXXXXXX When Setting as 26 0 The N 0 means Edit for Input equipment has already Messages for the system when started switch on Startup user defined information The equipment has already started XXXXXXX is the text messages content which can up to 70 2013 10 10 17 24 Thu alphabet When the text message content successfully programmed it will overwrite the system default text messages 31 Check input messages programmed 27 N When Setting as 27 0 N 0 means Check the Input in the system Startup user defined Messages for
2. 17 SMS Reply Message when the system ON OFF 21 N Message switch lt ON gt 2013 10 10 17 06 Thu N 0 means SMS Reply Message when the system OFF N 1 means SMS Reply Message when the system ON Factory Default as SMS Reply Message when the system ON If setting to not receive SMS Reply Message when the system OFF the unit will return a message indicate successful setting for the command and it will no longer sending SMS reply until the setting of SMS Reply Message when the system ON is done When the system having the temperature alert it will automatically sending the alert message to the Admin 18 To receive SMS Reply Message or not to receive SMS Reply Message when the system trigger by phone call 22 N When sending command 22 0 Status switch lt OFF gt 2013 10 10 17 10 Thu When sending command 22 1 Status switch lt ON gt 2013 10 10 17 08 Thu N 1 means after make the phone call to the system it will return the SMS for the status to the caller N 0 means after make the phone call to the system it will not return the SMS for the Status to the caller Factory Default as return SMS for the status after make the phone call If you decide not to allow the system to text you for any acknowledgement after you call to the unit You can switch OFF the text message Some Customer request this function because texts reply involved call cost 19 Security mode Open Mode
3. Easy Switch GSM Temperature Alert and Monitoring System USER MANUAL Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 INTRODUCTION The Easy Switch GSM Temperature Alert and Monitoring System allows the user to pre set a temperature range and receive an alert via SMS and phone call if the current temperature exceeds the pre set range If the temperature is too low or too high the GSM temperature alert system will call and send a warning SMS messages up to 5 users allowing you to take action or you can call to the unit to activate the relay manually or let the unit active the relay automatically to correct the temperature The temperature sensor can be adjusted from minimum 49 to maximum 129 Celsius and the unit can be set to alarm on over temperature or under temperature In case the temperature problem is due to power failure the system incorporates a 7 2V backup battery will take over when the main fails The unit also has 1 x 30A heavy duty relay output can be used to switch on any application like lamps pumps heaters motor etc when temperature exceeds the pre set range Output relay can be switched ON or OFF by calling its cell phone number or by sending an SMS command there is no call charges incurred when dialling the unit as it will recognize an authorised telephone number calling it and reject the call without answering This function is important to switch on the pump air conditional water supply
4. 08 Mon ON Time 14 Setting high and low temperature 16 N XXX Low temperature 2 degree N 0 Low Temperature Alarm alarm value celsius Value N 1 High Temperature Alarm 2013 10 10 16 53 Thu Value When temperature is positive Or XXX is the 3 digit value in C When temperature is negative High temperature 32 degree the 1st value of X is negative celsius the last 2 XX is the 2 digit temperature value in 2013 10 10 16 53 Thu XXX 49C to 129 C For Example 16 0 02 means setting the low temperature value as 2 C For Example 16 0 032 means setting the high temperature value as 32 C Note When the temperature is higher or lower than the temperature value that set all the Admin will receive the temperature alert message High temperature alarm The temperature is 30 degree Celsius 2013 10 15 16 09 Tue 15 Checking the high or low 177 Temperature 29 degree Checking the Temperature temperature value LIVE celsius Status LIVE High temperature 32 degree celsius Low temperature 2 degree celsius 2013 10 10 16 54 Thu 16 Delete the High and low 18 N High temperature N 0 means delete the low temperature alarm value Low temperture 2 degree celsius 2013 10 10 16 56 Thu temperature alarm value N 1 means delete the high temperature alarm value For example 18 1 to delete the high temperature alarm value Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3
5. changing to another network provider 3 Lam not receiving confirmation test messages when program the administrators number Ensure your telephone number is in the Administrator list and that sending text messages to your number is enabled 4 lam not receiving any text messages when initially programming the unit Ensure the unit is connected to the GSM network by observing the blue network LED it should be flashing once every 3 seconds see 2 above Ensure the SIM card has credit 5 The unit has been working for several months and has now stopped responding to calls and text commands Most but not all PAY SIM cards will be de activated by the network if not used to make an outgoing voice call or send an SMS text message within a specific period To prevent this simply send a txt command 0 PWH then 2 it will reply by text message do this once a month to keep the SIM card active Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3
6. if temperature beyond the setting point and to maintain the room temperature The user also can set to switch on off the generator fan AC pumps lighting automatically if temperature go beyond the set point by performing a very simple texts commands as per the below setting instruction The unit will keep monitor the current temperature in the areas The user can request the current temperature by sending a text message to the device The user will receive an SMS with the current temperature level This unit supply with all the accessories you need together with a temperature sensors 3 meters lengths If you required for additional lengths please discuss with your distributor Beside temperature input the unit supply with 2 digital inputs The digital input can connect to any alarm sensors to monitor the security in the room For examples magnetic door senor motion detector and etc The unit detect loss of power Once power outage is detected the unit will call and SMS to your cell phone and or sound an auditable alert to make you aware of the power failure The system using CE and FCC approved industry internal power supply connected on board A backup lithium battery can power up at least 8 hours and will sent a power down or power restored alerts in the event of power failure Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 The GSM Remote Control system supports timer function the user can set sched
7. ON OFF for the 13 N YYYYMMDDHHMM Master relay off time N 0 Switch Off the Master Master Relay 2013 10 10 16 33 Relay N 1 Switch On the Master 2013 10 10 16 31 Thu Relay When the programmed time is reach the relay is YYYY 4 digit for Year either on or off all the MM 2 digit for Month admin will get the reply DD 2 digit for Date SMS as per below HH 2 digit for Hour MM 2 digit for Minutes Since time is up Master relay lt OFF gt 2013 10 10 16 33 Thu Example se H 13 0 201310101633 which Note if the system is means 2013 10 10 16 33 to only ON after the switch off the master relay scheduled time the unit will still running If reprogram the date it will accordingly take the last as the correct date If you program the date that System startup already past the system will Master Replay lt OFF gt alert you 2013 10 10 16 33 Thu 12 Checking the schedule time for 14 Master relay on time Checking the schedule time for Master Relay ON OFF Master relay off time 2013 10 10 16 33 2013 10 10 16 35 Thu Master Relay ON OFF when the time reach the system will Operate and it will delete the schedule time automatically Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 13 Delete the schedule time for the 15 N Master relay on time N 0 Delete schedule of Relay Master Relay ON OFF Master relay off time OFF Time N 1 Delete schedule of Relay 2013 10 14 11
8. ease refer to your network operator if outside the UK Vodafone 1210 gt Send you will hear order is accepted and confirmed O2 Call 1760 gt Send you will hear order is accepted and confirmed T Mobile Call 222 and follow instructions Orange Call 450 and follow instructions The SIM card is now ready to use We recommend that if you are using a pay as you go PAYG SIM card that you choose to automatically Top Up when the cards credit falls below a certain limit please contact your network provider or visit their website for more details Most but not a using post paid SIM cards will be de activated by the network if not used to make an outgoing voice call or send an SMS text message within a specific period To prevent this simply send the GSM Remote Control Switch a text command 0 PWH then 2 it will reply by text message do this once a month to keep the SIM card active Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 Troubleshooting 1 Red power LED not alight Ensure that your DC power supply is connected correctly positive to terminal 220v and negative to terminal N Verify 12 volts is present using a volt meter 2 Blue network LED flashing every one second and not every 3 seconds Ensure your SIM card has been activated and that the PIN request has been disabled If the unit is in a low signal strength area consider using an external GSM antenna or
9. ive alarm texts message and active the relay output You can add up to 5 telephone number into the admin list 4 Check phone number you a2 Administrator program in the list 1 15989427391 2 18617185300 3 4 5 2013 10 10 16 08 Thu 5 Delete the admin number in the list 3 N Administrator Delete Admin Number N Admin number 1 5 For example if you want to delete admin no 2 just enter 3 2 1 15989427391 On a et 2013 10 10 16 08 Thu Delete 1st admin 3 1 Delete 2nd admin 3 2 Delete 3rd admin 3 3 Delete 4th admin 3 4 Delete 5th admin 3 5 Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 6 Check the relay status in ON or OFF Mode 4 Master relay lt ON gt 2013 10 10 16 10 Thu The unit will return Master relay lt ON gt if the relay is on The unit will return Master relay lt OFF gt if the relay is off 7 Check Signal Strength CSQ lt 28 gt 2013 10 10 16 11 Thu You must confirm the signal strength at site before you install the unit If the signal too weak the unit will not function properly CSQ 5 12 Signal too weak system not function CSQ 13 24 Signal Good System function well CSQ 25 32 Signal Excellent System working well Activate or Deactivate the Alarm Function 10 N When Sending 10 0 Alarm switch lt OFF gt 2013 10 10 16 28 Thu N 0 Deactivate Alarm Function N 1 Activate Ala
10. k Call Costs Beside calls to switch off or on the unit also can be permanently switch off and on by sending the unit a text message com mand Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 Step 1 The simplest set up methods to set up Administrator number Applied the KISS Principle keep it simple stupid The GSM Remote Control Switch is easy to setup and use Insert the SIM card simply use your mobile phone call to the unit your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit Administrator 1 18617185299 your phone number 2 3 4 5 fom fare Test Si SE oan You already finish the set up Now you can use your mobile phone call to the SIM Card number switch the device on permanently Another call to the SIM Card will switch the device off permanently If you do not required to go through details setting please process to STEP3 Final Installation and Wiring Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 Factory Reset If you required to change the administrator number in the future simply press the button FACTORY at the mother board until you hear the du This means the unit back to the factory default Press until you hear the du sound This means you already reset the unit to factory default Now you can start to call again to set the admi
11. k provider before they can be used usually by calling the network provider or registering on their website please refer to the instructions supplied with your SIM card During the registration procedure a confirmation code or text message is usually sent to the SIM cards telephone number to be able to read and react to the message you will need to insert the SIM card into an unlocked mobile phone After successfully registering the SIM card ensure there is sufficient credit on the card for programming confirmation texts to be sent from the GSM Remote Control Switch You MUST ensure that the PIN request is disabled from the SIM card before inserting it into the GSM Remote Control Switch If you do not disable the PIN request the GSM Remote Control Switch will not work If the PIN request is not disabled and the unit is switched on more than 3 times you will have to reset the PIN using the PUK code which will have to be obtained from the service provider To check the PIN request status of your SIM card place the card in an unlocked mobile phone switch the phone on If you are able to make calls without entering a PIN number the PIN request is disabled If a PIN number is requested refer to the instructions supplied with the SIM card and then look through the phones options for the disable PIN request and disable it You MUST disable any voicemail that is set up on the SIM card the codes shown below are for UK networks only pl
12. nistrator This method of setting is only allowed to set 1 administrator number If you wish to set more administrators please go to Step 3 Installation and set up Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 Step 2 Advance Set Up 1 First Step of programming you 0 1234 You get administrator When you enter 0 1234 you must enter the factory passwords of privileges enter into the programming 1234 and go inside the mode You must perform the programming mode 2013 10 09 00 33 Wed next command in 10 minutes If you did not do anything the You only can perform the next system will exit from commands after enter into programming mode programming mode 2 Change Password 0 1234 new password New password lt 1212 gt Maximum 4 digits of passwords For example if you need to 2013 10 10 16 07 Thu If you decide to protect your change to the new PW of privacy you can change the 1212 factory password to your new password 0 1234 1212 Enter the factory password follow by your new password 3 Add telephone number into the 1 1 telephone number Administrator Set Admin Numbers admin list 1 15989427391 1 1 set Ist admin number For example set Admin 2 18617185300 1 2 set 2nd admin number number 18617185300 into 3 1 3 set 3rd admin number admin 2 4 1 4 set 4th admin number 5 1 5 set Sth admin number 1 2 18617185300 2013 10 10 16 08 Thu Only the number in the list can rece
13. rm Function Factory Default Setting as N 1 For example if you want to activate the alarm function just enter 10 1 When Deactivate Alarm Function is equal to using the Remote Control to disarm The D7 Green LED light in the system will turn off All the function such as Outage Alarm Temperature Report When deactivate alarm function all the alarm message will be deactivate When Activate Alarm Function is equal to using the Remote Control to arm The D7 Green LED light in the system will turn on All the function such as Outage Alarm Temperature Report 9 Checking the status of the Alarm Function in the system 11 Alarm switch lt ON gt 2013 10 10 16 29 Thu Check the status of the alarm function in the system Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 10 Setting the year month day hours 12 YYYYMMDDHHMMX Time change OK YYYY 4 digit for Year minutes week MM 2 digit for Month 2013 10 10 16 05 Thu DD 2 digit for Date HH 2 digit for Hour MM 2 digit for Minutes X 1 7 Day of the Week Example set as 12 2013101016054 which means 2013 10 10 16 05 Thu If reprogram the date it will take the last as the accurate date The date have to be correct if setting 2014 2 29 or 2013 11 31 this is the incorrect date which is not occur the system will verify the date time day if correct the date have to be after year 2013 nb Schedule the
14. s only work with our Temperature Sensors The Connect 11 12 and 13 is inside the Industry Power Supply If Wire between the J16 Connector 3 and 4 Is Disconnect the Admin number will receive SMS Alarm The line is broken 2013 10 15 16 24 Tue Example Wiring Diagram For Digital And Analogue Input Counter Level Temperature NC NO COM L N Dry Contact 12V For any Alarm Sensors ss E g Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 Example Connection of Relay Output to Water Supply Pumps AC Wiring Diagram Easy Switch GSM Remote Switch Wiring Diagram Easy Switch GSM Remote Switch NO NC COM GN L A L N ce Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 Example Connection with Freezer Wiring Diagram Easy Switch GSM Remote Switch Production Specifications Operation Voltage 12 volts DC Operating Current Maximum 500mA typically 55mA Relay Contacts 1 x Normally Open and Normally Closed Contacts maximum switching capacity 20 amps 230v ac per relay GSM Frequency MHz GSM 850 GSM 900 GSM 1800 GSM 1900 Humidity Less Than 80 RH Operating Temperature 20c to 55c Physical Size 130 x 100 x 50mm Protection IP 65 Weather Proof Casing Approvals CE EGC ETSI Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 Preparing the SIM card All new SIM cards have to be registered with the networ
15. sy Switch GSM Switch Temperature Alert User Manual V1 3 Step 3 Installation Reset Button 3G GSM Module SIM Card Holder Antenna Timer Network LED Green PowerLED RED Relay LED Connectto backup battery Pulse Counter Temperature Input Industry Power Supply input FCC CE Approved Digital Input 30A Relay Insert the SIM card to access the SIM card carrier gently push the button adjacent to it insert the SIM card and carefully close the carrier Connect the cable to terminals 110V 220V amp N ensuring positive is connected to terminal 110v 200V switch on the power supply the red power LED will light indicating power is present the blue network LED indicator will initially flash quickly once logged onto the network it will flash more slowly approximately one every 3 4 seconds It is recommended that the GSM Remote Control Switch be programmed to operate as required before final installation Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 Connection Details If you are unsure how to connect the device you wish to control refer to a qualified person Connector 1 2 3 4 5 6 7 8 9 10 11 12 13 Board Label J12 J16 J14 J3 Power supply Description take Line Temperature alarm Rela Power suppl p counter P Y PPIV Details line GND Data GND 5V NC NO Com E N L Note 1 The Temperature Input i
16. the system when information The equipment switch on has already started If there is no text message 2013 10 10 17 36 Thu programmed it will return a SMS with Blank Message 32 Delete input messages programmed 28 N When Setting as 28 0 N 0 means Delete the Input in the system Startup user defined information 2013 10 10 17 42 Thu After delete success when system restart admin will receive the default text message System startup Master relay lt OFF gt 2013 10 10 17 45 Thu Messages for the system when switch on If there is no text message programmed it will return a SMS with Blank Message Holars Easy Switch GSM Switch Temperature Alert User Manual V1 3 33 Method the relay ON when there is alarm 32 N When sending 32 1 Linkage High temperature 2013 11 30 09 44 Sat N 0 means when the system have alarm alert it will not switch on the relay the relay will not action if there is any alarm alert N 1 mean when high temperature will switch on relay when low temperature will switch off relay N 2 means high temperature will switch off relay when low temperature will switch on relay Default as N 0 which when reach the pulse counter value will switch on relay This command only can operate when the Master Relay under Open Mode which mean the command 23 0 If it is under Security Mode the Master Relay will no function Holars Ea
17. ule to turn on off the switch For example put your air conditional fan UV lighting on a schedule Turn off in 5 minutes turn ti on at 17 00 turn on 1 year later This function is important for application to switch on the fan AC lighting for certain hours and switch off automatically This application is widely use in the green house chemical freezers which required certain time to increase decrease the temperature ranges The timer function also is an important feature to remind the owner to monitor the SIM Card expiry date User can set the date and time and let the unit automatically sent the SMS text messages to the user to keep the SIM card active when expiry dates SETTING UP AND PROGRAMMING When first booting up the system you will see Green LED Lights on the side of the Enclosure and it should light up when the Network is applied to the unit The Green LED is the network Indicator and this will light up when attempting to log on to the network flash inconsistently until it locates the network A Phone Call to the SIM Card Number will now Latch the Relay permanently ON and Switch the device being Controlled On The Status of the Relay will remain as on until the unit receives a second Call to the Unit of which will now Latch the Relay Permanently off Both Calls used to Latch the Relay either on or off are automatically disconnected once the relays are activated and never incur any Networ
Download Pdf Manuals
Related Search
Related Contents
! 警 告 ! 注 意 高天井用 LED 照明器具 取扱説明書・施工説明書 GE Monogram Compactor User's Manual Philips Sonicare HealthyWhite HX6712/43 electric toothbrush 秋桜(コスモス) eVolution ORCA Wireless Laser Design Desktop 2400VS-DL-VA, 192 Video Segment Instant Access System for User Manual Fernanzeige DuoC intext:Bedienungsanleitung filetype:pdf Copyright © All rights reserved.