Home
Flasher
Contents
1. Flasher Flasher ba Flasher Control channels dimmer Channel 1 allows linear control of luminous intensity from zero to 100 When channel 2 strobe is set at 0 zero channel 1 enables SINGLE SHOOT use In this case a single flash is given at the power required by the operator it s sufficient to use the channel 1 slider on the desk or the controller starting from 0 and stopping at the value of the required scale parameter 0 10 0 255 or 0 100 according to the controller used When the value of channel 1 or channel 2 is 0 zero the fixture automatically goes into standby the Flasher doesn t in fact have a power switch which is replaced by the control electronics strobe Channel 2 allows the flash rate of the Flasher to be regulated continuously The range goes from zero to 50 flashes per second i e from off to continuous light When channel 1 or channel 2 are set at 0 zero the fixture automatically goes into standby the Flasher doesn t in fact have a power switch which is replaced by the control electronics Setting the strobe at 0 zero enables SINGLE SHOOT use see channel 1 dimmer SIGIM LIGHT TECHNOLOGY Via Pio La Torre 1 61010 TAVULLIA PS e ITALY Tel 39 0721476477 Fax 39 0721476170 www sgm it info sgm it cod M001165
2. with temperatures higher than 45 C or lower than 2 C Protect the equipment from excessively humid conditions the optimum values are between 35 and 80 Do not disassemble or modify the equipment Prevent inflammable liquids water or metallic objects from penetrating the equipment In case of spilling liquid on the equipment immediately disconnect the power supply of the mixer The minimum distance between the projector and the surface to be illuminated must not be less than 1 5 m In case of serious functioning problems switch off the equipment and contact the nearest SGM retailer or the manufacturer directly for inspection Avoid opening the equipment there are no parts repairable by the user Never try to repair the equipment alone Repairs carried out by inexpert persons may cause damage or serious malfunctioning Contact the nearest authorised Technical Service Centre Always insist on original spare parts Protect the environment do not throw the packaging in your dustbin but return it to your retailer or take it to a collection point for special waste disposal ED D DD D E eta SIGIM page 1 SIGIM page 2 O O QQ QO a a a A A A A WO WwW WB W N Index General information Index Main features Lamp Dimmer Technical specifications Positioning Flasher DMX 1 5 maintenance Access to internal components Fitting the lamp and re lamping Cleaning the fixture periodic checks Switching the fixture on fi
3. PERSONNEL SUF FICIENTLY INFORMED ON RISKS AND METHODS OF OPERATION Cleaning the fixture periodic checks Cleaning the glass and reflector inside and out is decisive for the utmost lumi nous output and must be carried out periodically Cleaning frequency depends above all on the surroundings in which the unit is used damp smoky or dusty surroundings in particu lar favour a greater build up of dirt on the unit s glass Clean using a soft cloth and normal glass cleaning products or methylated spirits always being certain to dry the parts Clean the outside of the glass at least every 15 20 days and the inner group at least every 40 60 days To ensure utmost fixture efficiency it s advisable to carry out a general periodic check up every 700 running hours Electrical and mechanical components must be checked by qualified technical person nel Switching the fixture on fixture status The Flasher doesn t have a manual switch for turning it on In fact its special electronics check the DMX signal line continually and only turn on the fixture when the control signal is sent In particular when channel 2 see further ahead is set at 0 zero the fixture automatically goes into stand by The power supply connector is used as a local cut out The red pilot light below the connector indica tes that there is voltage on the in coming power line The green DMX OK LED indicates that the connection of the DMX network is operating a
4. SIGIM LIGHT TECHNOLOGY R C reo Qe N Flasher 1 6 professional strobe projector rel 1 00 user manual General warnings Carefully read the warnings contained in this manual since they supply important instructions concer ning safety of installation use and maintenance It is very important that this manual be kept with the equipment for future consultation In case of sale or transfer of the equipment to another user ensure that this manual always accompanies the equipment to allow the new owner to obtain information about the operation and the relevant warnings Not for residential use After unpacking check the integrity of the equipment In case of doubt do not use the equipment and contact an authorized SGM Technical Service Centre The packaging materials plastic bags expanded polystyrene nails etc must be kept out of reach of children since they are potential sources of danger This equipment may only be operated by adults Do not allow children to tamper with the machine or play with the product The electrical and mechanical work necessary for the installation of the equipment must be carried out by a qualified electrician or by a competent person Before connecting the unit check that the data on the registration plate is the same as that of the electrical grid Avoid using the equipment in places subject to excessive humidity in places subject to vibrations or knocks in places
5. mp with exceptional luminous output optimized by electro nic control Dimmer The Flasher also has a dimmer function that enables flash power to be adjusted from zero to 100 Technical Specifications Power required 90 260V 50Hz 60Hz universal automatic voltage changer Lamp 1 500W XOP15 special base Power absorbed 400W Reflector Polished aluminium with high transmission factor Electronics Completely designed by SGM R amp D lab engineers Main board CS 0218 input board CS 0217 and IGBT controller board CS 0228 Settings Via rotary dip switches for addressing the fixture s control channels Input ch1 dimmer ch2 strobe Safety norms Protected to IP20 Automatic power cut off in the event of overheating or faulty cooling system operation Cooling Forced ventilation via an axial fan Body Sheet metal with epoxy powder finish Mounting bracket Steel metal with epoxy powder finish Dimensions 49 x 21 x 17 cm Weight 5 6kg SGM Elettronica reserves the right to carry out improvements or modifications on its products without prior notice Always consult the handbook of the unit being used to avoid errors and any difference between actual functions and handbook contents ED D D PD E e SIGIM page 3 SIGIM page 4 Positioning To position the fixture set the channels as follows Channel 1 dimmer 100 open Channel 2 strobe positioned at 128 ref scale 0 255 Position the fixture by turning it on the suppor
6. nd the signal matches protocol specs The red SYSTEM FAILURE LED lights up when the lamp doesn t light up in spite of the DMX com mand Striking lasts for a very short period approx 1 sec In this case call the nearest assistance centre disconnect the fixture from the mains supply and carry out a check Start addresses When connecting each fixture must be appropriately configured The start address is set using the rotary dip switch located on the rear of the fixture The address can be changed even when the fixture Is on The lowest start address is 001 When 000 is used as the address as in the following example the Flasher s built in computer uses 001 anyway x 100 x 10 x1 Flasher 1 ch 1 2 Flasher 2 ch 3 4 ch 5 6 appendice SIGIM page 5 SIGIM page 6 Connecting the Flashers The fixture has DMX 512 input output For connection always use quality balanced microphone cables DMX socket pin out such as RF 60 12 2x0 25mm or similar to avoid faulty fixture vi mn operation da To reduce interference it may be necessary to fit the last fixture in the DMX chain with a system terminator made using a 1200hm 1 4W resistor between pins 2 and 3 on the DMX con a Attention the cable screen sheath must NEVER be con nected to the system s ground as this would cause faulty fixture and controller operation Flasher 1 Flasher 2 Flasher n DMX512 line
7. t bracket and locking in the required position using the bolts supplied Flasher does not require focussing Trouble free horizontal vertical or tilted positioning is possible provided sufficient space is left round the unit for air circulation Flasher DMX 1 5 maintenance Access to internal components The Flasher has a system for access to the fixture s internal components which prevents accidental opening To open the fixture it must be dismantled from its operating position and disconnected from the mains supply screw 1 can then be unscrewed Once side panel 2 has been removed the front glass 3 must be removed extremely carefully If the fixture must be completely dismantled screw 4 and side panel 5 must also be removed The lamp and reflector can then be removed for access to the electronics Fitting the lamp and re lamping ATTENTION Before re lamping make certain that it s really necessary and discon nect the fixture s main power supply If the unit has been used recently wait for the lamp and mechanical parts to cool before opening 10 30 minutes Be very careful to avoid touching the reflector and the actual lamp with your bare hands as any residue subject to high temperature burns causing components to blacken and definitively damages the lamp Fit the new lamp carefully After re lamping it s always advisable to clean the fixture completely ATTENTION THIS TYPE OF LAMP MUST ONLY BE REPLACED BY QUALIFIED
8. xture status Start addresses Connecting the Flashers Control channels ch 1 dimmer ch 2 strobe SIGIM LIGHT TECHNOLOGY Made in Italy by SGM Electronic Printed in July 1998 Rel 1 00 Main features SGM s new Flasher DMX 1 5 strobe unit is another result of the firm s lengthy experience in manufac turing this type of fixture The quality and design philosophy are those which all SGM products have had in common for years and the sophisticated electronics used combined with ground breaking performance earn it a rightful place at among the world s top products In depth function study an on going search for innovative materials technical updating and constant research aimed at ensuring even further safety have resulted in a truly unique product The mechanism and electronics were designed entirely by our in house research labs ensuring com plete command of all know how and an optimum quality price ratio Like all other SGM products the Flasher passed the firm s long trail period and strict tests brilliantly before being put on the market ensuring high quality and reliability up to the firm s customary stan dards Particular care taken with the unit s looks and optimisation of the outer structure to ensure functiona lity enable the fixture to be easily installed in any position and ensure extremely rapid maintenance The Flasher is built in compliance with current CE norms Lamp The Flasher is fitted with a Xenon XOP15 la
Download Pdf Manuals
Related Search
Flasher flasher meshtastic.org flasher relay flashers in eyesight flasher rigs fishing flasher light scooter flasher relay for turn signal flasher unit flasher equipment san antonio flasher blinker accessories flasher public schools flasher relay for led light flasher led universal flashers and floaters in eyes flasher nd county flasher-stm32 flasher bitronics store flasher motor flasher compact flasher iphone flasher android flasher relay indicator light flasher relay diagram flashers for fishing flasher un telephone flasher android avec pc
Related Contents
SPP-R210 Ninja BL800 Owner's Guide NEC Gefen EXT-DVI-841 video switch Télécharger la fiche technique Samsung WB650 Benutzerhandbuch Samsung GT-S8000 Felhasználói kézikönyv Implementation of DCA Compression Method Introduction aux AVR Copyright © All rights reserved.
Failed to retrieve file