ACD-4 Mini-Clamp DMM Product Manual
Contents
1. 4 Mini Clamp DMM 400A Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso AMPROBE ACD 4 Mini Clamp DMM 400A Users Manual E Sos Test Tools All rights ved Printed in Chin Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Amprobe s behalf To obtain service during the warranty period return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor See Repair Section for details THIS WARRANTY IS YOUR ONLY REMEDY ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STAUTORY INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY ARE HEREBY DISCLAIMED MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages this limitation of liability may not apply to you Repair All test tools returned for warranty or non warrant
2. Non Warranty Repairs and Replacement Europe European non warranty units can be replaced by your Amprobe Test Tools distributor for a nominal charge Please check the Where to Buy section on www amprobe com for a list of distributors near you Amprobe Test Tools Europe In den Engematten 14 79286 Glottertal Germany tel 49 0 7684 8009 0 Correspondence only no repair or replacement available from this address European customers please contact your distributor ACD 4 Mini Clam DMM 400A Ci Current Jaws Jaw Opening Lever Q Hold function key Push button for Vac Vdc Selector switch or Resistance Continuity measurement Q Common Ground reference input jack LCD Display Input jack for voltage and resistance function ACD 4 Mini Clam DMM 400A CONTENTS Ode EE 2 UNPACKING AND INSPECTION 3 INTRODUCTION iie ee eterne eee 3 OPERATION m 3 Ed ellen el Ee CREDE 4 6 D gd pdgmmee 9 TROUBLE SHOOTING nter enero deer etc Lo ete Ree ER re ed eren an 10 Battery Replacement E a ere EE 10 SYMBOLS A Warning Dangerous Voltage Risk of electric shock A Caution Refer to the user s manual before using this Meter Double Insulation or Reinforced insulation Alternating Current AC Direct Current DC Low battery indicator Groun
3. EEC CE Marking However electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference MAINTENACE If there appears to be a malfunction during the operation of the meter the following steps should be performed in order to isolate the cause of the problem 1 Check the battery Replace the battery immediately when the symbol appears on the LCD 2 Review the operating instructions for possible mistakes in operating procedure Except for the replacement of the battery repair of the meter should be performed only by a Factory Authorized Service Center or by other qualified instrument service personnel The front panel and case can be cleaned with a mild solution of detergent and water Apply sparingly with a soft cloth and allow to dry completely before using Do not use aromatic hydrocarbons or chlorinated solvents for cleaning If the meter is not to be used for periods of longer than 60 days remove the batteries and store them separately Do not attempt to repair this Meter It contains no user serviceable parts Repair or servicing should only be performed by qualified personnel 9 TROUBLE SHO
4. Over voltage protection DC AC 600V Input Impedance CMRR NMRR VAC VDC AC Conversion Type 10 A less than 100pF Common Mode Rejection Ratio Normal Mode Rejection Ratio CMRR gt 60GB at DC 50Hz 60Hz CMRR gt 100dB at DC 50Hz 60Hz NMRR gt 50GB at DC 50Hz 60Hz Average sensing rms indication AC Current Range DC Accuracy AC Accuracy 0 0 40 0A 1 9 10 dgt A 0 50 60Hz 40 0 200 0A 1 9 5 dgt 201 400A 1 9 5 dgt Overload protection 600 Arms AC Conversion Type Position Error Average sensing rms indication 1 5 of reading Resistance Range Accuracy 200 00 3 1 0 5 dgt 2 2 000 3 20 00 3 0 7 2 dgt 200 00 3 2 000 3 1 0 2 dgt 20 00 KO 3 x 1 996 5 dot 1 Overload protection 600V rms Open circuit Voltage 1 3V approx 1 100 dgt rolling 2 10 dgt rolling 3 The maximum LCD reading is 1400 counts Continuity Internal beeper activates if the resistance of the circuit under test is less than 200 It will then turn off if the resistance is increased beyond 500 Response time is approximately 50m sec Overload protection 600V rms 61326 1 This product complies with requirements of the following European Community Directives 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage as amended by 93 68
5. OTING If the instrument fails to operate check batteries and test leads etc and replace as necessary Double check operating procedure as described in this user s manual If the instrument voltage resistance input terminal has subjected to high voltage transient caused by lightning or switching surge to the system by accident or abnormal conditions of operation the series fusible resistors will be blown off become high impedance like fuses to protect the user and the instrument Most measuring functions through this terminal will then be open circuit The series fusible resistors and the spark gaps should then be replaced by qualified technician Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service Battery Replacement Refer to the following figure to replace the batteries 10 Visit www Amprobe com for e Catalog Application notes Product specifications e User manuals e Please Recycle
6. d maximum permitted voltage between terminal and i e ground A Please remove all the test leads before preforming maintenance cleaning battery replacement fuse replacement etc C Complies with European Directives Q Conforms to relevant Australian standards amp Do not dispose of this pruduct as unsorted municipal waste Contact a qualified recycler for disposal 4A Warnings To ensure safe operation and service of the Meter follow these instructions Failure to observe warnings can result in severe injury or death Do not operate this meter in explosive gas material combustible gas material steam or filled with dust When using test leads or probes keep your fingers behind the finger guards Remove test lead from Meter before opening the battery door or Meter case Avoid working alone so assistance can be rendered Do not use test leads or the Clamp Meter if they look damaged Do not use the Meter if the Clamp Meter is not operating properly or if it is wet Use the Clamp Meter only as specified in the Instruction card or the protection by the Clamp Meter might be impaired Individual protective device must be used if hazardous live parts in the installation where the measurement is to be carried out could be accessible UNPACKING AND INSPECTION Your shipping carton should include 1 ACD 4 Meter 2 Test Leads 2 Battery SIZE AAA 1 5V 1 User s Manual If any
7. ery life ALKALINE 200 hours Environmental Conditions Indoor Use Calibration One year calibration cycle Operating temperature 0 C 32 F 30 C 86 F 8096 RH 30 C 86 F 40 C 104 F 37596 RH 40 C 104 F 50 C 122 F S45 RH Storage temperature Overvoltage category 20 to 60 C 4 F to 140 F 0 to 80 RH batteries not fitted IEC 61010 1 600V CAT III CAT Application field The circuits are not connected to mains Il The circuits are directly connected to Low voltage installation M The building installation V The source of the Low voltage installation Operating altitude Conductor Size Pollution degree EMC Shock vibration Drop Protection Dimensions W x H x D Weight Accessories Electrical Specifications 2000m 6562 ft 27mm 1 06 in diameter 2 EN 61326 1 Sinusoidal vibration per MIL T 28800E 5 55 Hz 39 0 007lb maximum 4 feet drop to hardwood on concrete floor 56mm x 188mm x 28mm 2 2 in x 7 4 in x 1 1 in 225g 0 5 Ib including battery Battery installed Carrying case Test lead and User manual Accuracy is reading number of digits at 23 C 5 C 73 4 F 41 F 8096 RH Temperature coefficient Add 0 2 x Specified accuracy C lt 18 C 64 4 F gt 28 C 82 4 F DC AC Volts Range DC Accuracy AC Accuracy 200 0V 1 5 5dgt n 1 600V On 50Hz 500Hz
8. of the items are damaged or missing return the complete package to the place of purchase for an exchange INTRODUCTION This meter ACD 4 can be used to measure voltage resistance and current It is an electronic measuring instrument that combines several measurement functions in one unit ACD 4 multimeter is portable hand held devices useful for basic fault finding and field service work It can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as batteries motor controls appliances power supplies and wiring systems OPERATION Power On Off COM A v a Dep Ga Auto Power Off S The meter will automatically shut itself off after approximately 10 minutes after power on Discharge hight voltage Capacitor Continuity Tester Ku ACA Measuring 1 4 0 CAT III 600V with respect to earth for the jaw Tactile Barrier for hang guard Do not hold the meter across the Tactile Barrier SPECIFICATIONS General Specifications LCD display digits 3 1 2 digit large scale LCD readout Display count 2000 counts Measuring rate 1 5 times sec Overrange display OL is displayed for functions shows the real value for A and V function Automatic power off time Approximately 10 minutes after power on Low battery indicator is displayed Power requirement 1 5V x 2 batteries Batt
9. y repair or for calibration should be accompanied by the following your name company s name address telephone number and proof of purchase Additionally please include a brief description of the problem or the service requested and include the test leads with the meter Non warranty repair or replacement charges should be remitted in the form of a check a money order credit card with expiration date or a purchase order made payable to Amprobe Test Tools In Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product Please check the Where to Buy section on www amprobe com for a list of distributors near you Additionally in the United States and Canada In Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center see next page for address Non Warranty Repairs and Replacement US and Canada Non warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett WA 98203 Mississauga ON 142 1X9 Tel 888 993 5853 Tel 905 890 7600 Fax 425 446 6390 Fax 905 890 6866