1. MENU press button Date select date OK change date V A increase decrease value OK accept value MENU back to menu Calibration Calibration date and software version display MENU press button Calibration select calibration OK display MENU back to menu Language MENU press button Language select language OK change language MENU Z back to menu Page 6 of 8 Wolfgang Warmbier Systeme gegen Elektrostatik set Limit BE 10 gt Ma 0 5 CRD Limit Folder Hame Date Folder Hame Time out 30s Date Calibration Date 02 10 09 12 fE 06 Calibration 16 06 09 Software 1 10 Time out 20 Temperatur Date Calibration Edition November 2009 SRM200 User s Manual Part No 7100 SRM200 Wolfgang Warmbier Systeme gegen Elektrostatik Additional user instructions for the Software are available on the CD ROM Packing List The SRM200 includes Surface Resistance Meter SRM 200 Carrying bag Battery charger USB data cable Software on CD ROM Grounding cord User s manual German English Calibration certificate Warranty The warranty does not include the rechargeable battery battery damage due to drainage and mechanical damage of the instrument The warranty is void ifthe unit is opened Notice This instrument is not approved for measurements in explosion hazard areas High electrostatic charge
2. User s Manual Surface Resistance Meter SRM 200 Wolfgang Warmbier e K Untere Gie wiesen 21 D 78247 Hilzingen www warmbier com SRM200 User s Manual P Part No 7100 SRM200 Wolfgang Warmbier Systeme gegen Elektrostatik Table of Contents Page 2 of 8 Edition November 2009 SRM200 User s Manual Part No 7100 SRM200 Wolfgang Warmbier Systeme gegen Elektrostatik Introduction The SRM110 is a pocket size lightweight auto ranging surface resistance tester Measured values are displayed on an LCD dot matrix module and can be stored in the internal memory Each measurement includes the current temperature and relative humidity Built in electrodes with conductive rubber make good contact with the object under test IEC compatible electrodes can be externally connected for tests according to IEC 61340 4 1 IEC 61340 2 3 and IEC 61340 4 5 The measuring voltage is auto ranging from 10V to 100V Operating Instructions Operation Description 1 Socket for external probes 2 LCD Display 3 Range LED s LED Measuring range Definition Green lt 1x10 Q 9x10fQ Electrostatic conductive Yellow 1x10 Q 9x10 Q Electrostatic dissipative Red gt 1x10 Q Electrostatic insulating 4 Buttons Up Down MENU OK Button Function MENU Open menu Return from sub menu OK Confirm or change value Increase value Scroll down in menu Decrease value Scroll up in menu Simultaneously pres
3. ilable Most of them can be accessed more conveniently by the PC software View results MENU press button View results select OK confirm V A select folder 1 99 OK confirm folder V A select record 1 99 OK display value Delete results MENU press button Delete results select OK confirm V A select folder 1 99 OK confirm folder A select record 1 99 OK confirm to delete V A Select yes OK delete value MENU back to menu Change Limits MENU press button Limit select limit OK select limit 1 19 down to name OK enter name for limit Page 5 of 8 1 10 om 23 497 EN 00 02710709 12 15 Folder 7 Record Date Time Delete data Series all Delete all res No Limit Bits 1 Name FLOOR 1x10 1107 Edition November 2009 SRM200 User s Manual Part No 7100 SRM200 Yy down to values OK change values V A increase decrease OK next value MENU back to limit MENU back to menu Folder names MENU press button Folder Name select A select folder to change OK enter text select character OK insert character MENU back to folder names MENU back to menu Timeout MENU press button Timeout select timeout OK change value MENU back to menu Temperature MENU press button Temperature select temperature OK change between or F MENU Z back to menu Date
4. ng range Temperature measuring range Humidity measuring range Rechargeable Lithium Battery 3 6V 900mAh R6 AA Charged via external power supply or USB interface 5 40 up to 75 rel humidity non condensing 10 50 up to 85 rel h umidity non condensing 2 banana sockets short version 15mm 1 10 1x10 Q 0 50 16 10 90 r F 5 Memory 9801 measuring values Test voltage 10V 100V automatic Dimensions 145 x 80 x 35mm LxBxH PC interface USB 2 0 Case ABS Weight 290 g Complies with CE Measuring range Display range Resolution Accuracy Test Voltage 10 Q 1x10 9x10 1 KO 10 reading 10V 10 Q 1x10 9 10 10 KQ 10 reading 10V 10 Q 1x10 9x10 100 kQ 10 reading 10V 10 Q 1x10 9x10 1 MO 10 reading 100V 10 Q 1x10 9x10 10 MQ 10 reading 100V 10 Q 1x10 9x10 100 MQ 10 reading 100V 10 Q 1x10 9x10 1 GQ 10 reading 100V 10 Q 1x10 9x10 10 GQ 25 reading 100V 10 Q 1x10 9x10 100 GQ 25 reading 100V 10 Q 1x10 1 TO 25 reading 100V Spare Parts Part number Description 7100 SRM200 CR 7100 SRM200 BAT 7100 SRM200 NT Page 8 of 8 Conductive rubber Set of 2 pieces Lithium rechargeable battery Power supply Edition November 2009
5. play will indicate the measured value being below or above the limit range e selects the storage folder OK stores the current measurement value to the selected folder PUSH TO TEST Measuring Resistance to Ground e Plug the supplied grounding cord at one socket of the instrument The associated internal electrode will be disconnected e Connect the opposite end of the grounding cord to ground or a groundable point e Hold the instrument onto the surface like described above and press the button PUSH TO TEST Page 4 of 8 Edition November 2009 SRM200 User s Manual Part No 7100 SRM200 Other Measurements Wolfgang Warmbier Systeme gegen Elektrostatik By connecting external electrodes to the instrument s sockets it is possible to measure point to point resistance or volume resistance for example Volume resistance Ry Test values Storage EE Metal counter electrode Probe model 850 Probe model 850 Surface resistance Rpp The included software can be used to transfer and process test values to the computer The functionality includes gt Measurement data transfer gt Store and export measurement data gt Print measurement report Functions gt Limit value definition gt Labelling of measurement folders gt Adjust Date and time The following functions are ava
6. s or measuring insulating highly charged materials might damage the instrument Using the instrument in power plants is not permitted Maintenance Battery condition is permanently monitored in the LCD display Connect the instrument to a computer or use the power supply to charge the battery in time The unit won t switch on if the battery is damaged Unscrew the battery lid at the backside of the unit to replace the battery Replace only a rechargeable battery of the same type and take care of the polarity Calibration The recommended calibration interval is 2 years Problem Solving Problem Cause Remedy No Operation Battery discharged Connect power supply to charge the battery No operation even after charging Battery defect Replace battery No operation after battery Wrong polarity Insert battery in correct polarity replacement red LED inside the battery case lit Conductive rubber defect Wear Replace contact rubber Page 7 of 8 Edition November 2009 SRM200 User s Manual Part No 7100 SRM200 Repair Wolfgang Warmbier Systeme gegen Elektrostatik Repairs shall be carried out by qualified personnel only In case you send the instrument for repair please pack it safely and state clearly the problem Waste Disposal Follow the local environmental rules when disposing of the equipment Technical Data Power supply Operating conditions Storing conditions Connectors Resistance measuri
7. sing A V turns the instrument off 5 Push to test button to switch ON and start measurement 6 USB connector for battery charger and PC connection Menu structure overview View results Display measurement results Delete results Delete measurement data Delete all data Delete all measurement data Limit Display or change limit values max 19 Folder name Display or change folder names max 99 Folder names can be entered more convenient by using the PC software Timeout Turn off delay time Temperature Change temperature between and F Date Adjust date and time Calibration Display calibration date and software version Language Language selection German English Page 3 of 8 Edition November 2009 SRM200 User s Manual Part No 7100 SRM200 Wolfgang Warmbier Systeme gegen Elektrostatik LCD display overview Measured value V View result mode active D Delete mode active Value exceeds Ense alue is below selected limit selected limit dempen 22 4 LIMITO1 gt 528 Relative humidity 05 01 10 09 11 09 Assigned limit Storage folder Date Time Battery status Measuring Surface Resistance e To measure the surface resistance of an object hold the instrument onto the surface and press the PUSH TO TEST button e The value is indicated on the display The coloured LED s additionally indicate the measuring range if no limit is assigned If the limit is assigned the limit arrows on the dis