KIEN1005G Industrial Ethernet Switch Hardware Installation Manual

image

Contents

1. mode conduction 30V cont 300V 1s Machinery Vibration IEC68 2 6 vibration amplitude 7mm acceleration 20 15 frequency range 2 9HZ 9 200HZ 200 500HZ Shock IEC68 2 27 duration of the half sine pulse 11ms peak acceleration 300m s2 Free Fall IEC68 2 32 Mass lt 20Kg 0 25m Industry IEC61000 6 2 Railway EN50155 EN50121 4 Y Cable Twisted Pair 100m Standard CAT5 CAT5e network cable Power Requirements 15 KIEN1005G User s Manual 201106 Power input 12VDC 9 36VDC 24VDC AC 18 72VDC 13 50VAC Power terminal 5 pin 5 08mm spacing plug in terminal block Power consumption full load 3 4W standby 0 99W Physical Charactreristics Installation DIN Rail or wall mounting Dimensions W XH XD 30mm X 115mm X 91 5mm Weight 0 76Kg Environment Limits Operating Temperature 40 C to 85 C 40 to 185 fF Storage Temperature 40 C to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing 9 MTBF 357000h Warranty 5 years For more information about KYLAND products please visit our website http www kyland cn 16
2. KIEN1005G User s Manual 201106 KIEN1005G Industrial Ethernet Switch Hardware Installation Manual HYLAND Kyland Technology Co LTD Publication Date June 2011 Version V1 0 Customer Service Hotline 8610 88796676 FAX 8610 88796678 Website http www kyland cn E mail support kyland biz No 1 12 02 1027 0 KIEN1005G User s Manual 201106 KIEN1005G Industrial Ethernet Switch Hardware Installation Manual Disclaimer Kyland Technology Co Ltd tries to keep the content in this manual as accurate and as up to date as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users Copyright O 2011 KYLAND Technology CO LTD All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation KIEN1005G User s Manual 201106 Notice for Safety Operation This product performs reliably as long as it is used according to the guidance Artificial damage or destruction of the equipment should be avoided O Read this manual carefully and keep it for future reference Oo Do not place the equipment near water sources or damp areas Do not place anything on power cable and put the cable in unreachable places O Donottie or wrap the cable to prevent fire O Power connectors and other equipment connectors should be firml
3. cing terminal block to connect power cable Note The cross section area of power cable is required to be greater than 0 75mm and less than 2 5mm2 The grounding resistance requirement lt 5Q 11 KIEN1005G User s Manual 201106 PWR1 PWR2 5 pin 5 08mm power terminal block SY O O 2 O r a br es a 1 2345 Contact definition DC wiring definition AC wiring definition 5 PWR2 PWR2 L Wiring and mounting Step 1 Take the power terminal block off KIEN1005G Step 2 Insert the power cable into the terminal block and fix the power cable Step 3 Put the terminal block back to KIEN1005G with the connected cable Grounding e Chassis grounding and power terminal grounding 12 KIEN1005G User s Manual 201106 Chassis grounding Surge grounding 18 AWG yellow green line There is a grounding screw on the top panel of the KIEN1005G which is for chassis grounding One end of the chassis grounding cable is connected with the grounding screw and the other end of the cable is reliably earthed The cross section area of chassis grounding cable should be more than 2 5mm The grounding resistance requirement lt 5Q The grounding part in the 5 08mm power terminal block is called surge grounding It is required to connect the chassis grounding part with the surge grounding part by an 18 AWG yellow green line as seen below 18 AWG yellow green line Unit mm ny OY e S s Hot shrinkage E
4. n rail transit and many other industries KIEN1005G industrial Ethernet switch supports DIN Rail and wall mounting It provides five 10 100 1000Base TX RJ45 ports in the front panel 3 Structure and Interface Front Panel 1 PWR1 Power 1 LED 2 PWR2 Power 2 LED 3 G1 G5 10 100 1000Base T X RJ45 ports KIEN1005G User s Manual 201106 Top Panel 1 Terminal block for power input 2 Screw hole for grounding ro 4 Mounting 9 Dimension Drawing for DIN Rail Mounting Unit mm Dimension Drawing for Wall Mounting Unit mm KIEN1005G User s Manual 201106 Note The switch housing is a part of the heat dissipation system which becomes hot during operation Please avoid contact Mounting Steps o KIEN1005G DIN Rail Mounting The specific steps are as follows Step 1 Select the mounting position for KIEN1005G and ensure that there is enough space Step 2 Insert the top of the DIN Rail into the spring supported slot of the DIN Rail connecting seat in the rear panel of KIEN1005G as seen below move the device in the direction of arrow 2 to put the whole Din Rail into the seat check whether KIEN1005G is firmly mounted on the DIN Rail as shown below KIEN1005G User s Manual 201106 DIN Rail DIN Rail y O Remove KIEN1005G from DIN Rail The specific steps are as follows Step 1 Plug the screwdriver into the hole at the bottom of spring locking plate press the plate down
5. nection 9 RJ45 Port o RJ45 port cable types and requirements 10 100 1000Base TX Ethernet RJ45 port can be connected to terminal equipment and network devices with straight through cables or cross over cables RJ45 connectors must be equipped at both ends of cable RJ45 connector and pin number 87654321 o Pin distribution of 10 100 1000Base TX MDI MDI X signal name Output Receiving data TRDO Output Receiving data TRDO Output Receiving data TRD1 Output Receiving data TRD2 Output Receiving data TRD2 Output Receiving data TRD1 Output Receiving data TRD3 Output Receiving data TRD3 Note means cable polarity 10 KIEN1005G User s Manual 201106 eo 1000M straight through cable wiring Straight through cable i Switch _ Network Interface Pin 1 RJ45 Connector RJ45 Connector a Wiring sequence TRDO 1 K TRDO TRDO 2 TRDO TRDI E 3 TRD1 TRD1 6 TRD1 TRD2 3 4 TRD2 TRD2 5 TRD2 TRD3 7 TRD3 TRDS 8 TRD3 e 1000M cross over cable wiring SR Cross over cable es Network Interface Network Interface Pin1 RJ45 Connector RJ45 Connector Wiring sequence TRDO na 0 N 00 tal Cw obo w N ce 1 TRD1 TRDO 2 TRD1 TRD1 3 TRDO TRD1 6 TRDO TRD2 4 IRD3 TRD2 5 TRD3 TRD3 3 7 TRD2 TRD3 8 TRD2 Power According to the power input requirements use a 5 08mm spa
6. sheath 18 AWG yellow green line i i 3 Dip soldering pl 20 0 5 y 13 KIEN1005G User s Manual 201106 Note If KEIN1005G needs to do a dielectric voltage withstand test in order to avoid the failure of test please disconnect the 18 AWG yellow green line to disable surge protection circuit that connects to surge grounding Disconnect 18 AWG yellow green line 6 LED Indicators KIEN1005G LED indicators Power LEDs Ethernet RJ45 port LEDs 1000M working state i e 1O00Base T Speed aaa OFF 10 100M working state i e 10 100Base TX or no connection l Effective network connection in the port Link Act a E G Blinking Network activities in the port reen No effective network connection in the port 7 Product Models The specific configuration models of KIEN10056 are shown in below table KIEN10056 Configuration Table 14 KIEN1005G User s Manual 201106 5 10 100 1000Base TX RJ45 12VDC 24VDC AC dual KIEN1005G 5GE Ports redundant power inputs 8 Basic Features and Specifications 9 Standard IEEE 802 3i IEEE 802 3u IEEE 802 3ab IEEE802 3z 9 Industrial Standard EMI FCC CFR47 Part 15 EN55022 CISPR22 Class A EMS IEC61000 4 2 ESD 8KV contact 15KV air 1EC61000 4 3 RS 10V m 80MHz 2GHz IEC61000 4 4 EFT Power Port 4KV Data Port 2KV IEC61000 4 5 Surge Power Port 2kV DM 4kV CM Data Port 2kV 1EC61000 4 6 CS 3V 10kHz 150kHz 10V 150kHz 80MHz IEC61000 4 16 common
7. to loosen the connection of DIN Rail and switch as shown in arrow 1 Step 2 Take up KIEN1005G in the direction of arrow 2 meanwhile remove the device from the DIN Rail along the direction of arrow 3 Spring Locking Plate o KIEN1005G Wall Mounting The specific steps are as follows Step 1 Select the mounting position for KIEN1005G on the wall or in cabinet ensure that there is enough space for the switch KIEN1005G User s Manual 201106 Step 2 Drill 4 holes on the selected position according to the wall mounting dimension drawings use a cross screwdriver to screw 4 cross slot screws M3 X 10 into holes Don t tighten up the screws completely leave about 5mm of space between Step 3 Aim 4 mounting holes on KIEN1005G mounting plate at 4 fixed screws pass the screws through 4 holes with the diameter of 6 5mm 6 5 then slide down KIEN1005G as seen below finally screw 4 screws tightly Now the KIEN1005G should be firmly fixed to the wall or cabinet Screw screw ca nd i if 1u a FE Oo Remove KIEN10056 from wall or cabinet The specific steps are as follows Step 1 Use a screwdriver to loosen 4 screws move the device up to let screws into 4 holes with the diameter of 6 5mm 6 5 Step 2 Unscrew the screws from wall or cabinet remove the device from wall or cabinet KIEN1005G User s Manual 201106 crew Screw 1 TE u nis DN UN L 5 Cable Con
8. y interconnected and checked frequently Oo Do not repair the equipment by yourself unless it is clearly specified in the manual Please keep the equipment clean if necessary wipe the equipment with soft cotton cloth In the following cases please immediately cut off the power supply and contact our company Water gets into the equipment Equipment damage or shell breakage Abnormal operation of equipment or its performances have completely changed Vv VY V WV The equipment emits odor smoke or abnormal noise KIEN1005G User s Manual 201106 Contents Paca td a e 5 Product OVervi CW Aemeecere armen re tree neey tier in ne rnnentarrer rr a E 5 structure and Merla Coca acca A dl e ale 5 MOUNUN O arotacann iberica bacon E 6 Cable Co A a a 10 EED Indicator Secene a ia eii 14 Product Modelen EE 14 Basler eat ures And SpeciicatiOns sacarina 15 KIEN1005G User s Manual 201106 1 Packing List KIEN1005G Industrial Ethernet Switch 1 Hardware Installation Manual 1 Certificate of Quality including Warranty Card 1 Note After unpacking please check the accessories and the appearance of the equipment If anything is missing or damaged please contact us 2 Product Overview KIEN1005G is a series of green low power consumption DIN Rail industrial Ethernet switch that can be applied extensively in wind power distribution network automation and subway PIS power SCADA wastewater treatment metallurgy intelligent transportatio