Home
ENIGMA II Monitoring Receiver
Contents
1. telephone line Connect the telephone line into the LINE SET RJ11 connector at the backside of the line card In case of ISDN line use one of the analog line outputs of ISDN NT box For two way audio connection the telephone set should be connected to LINE SET connector also The incoming telephone line should be connected to the two internal connector interfaces 3 4 telephone set should be connected to the two external connector interfaces 2 5 Pay attention that connected telephone set should be in line as if it is in hanged up state the two way audio connection doesn t work Check device impedance as well it should be 600 ohm for normal phone sets O LINE SET Analog telephone line connector II LineCard 2 GROUND Terminals to connect telephone line card into either of connectors O Note Grounding of housing and grounding of telephone line cards can be connected only at the common ground point at least 2 m distance between each card grounding point M5 nut terminals Grounding is essential for flash of lighting and over potential protection absence of proper grounding may cause communication problems as well RC radio receiver card backside connectors optional RC radio receiver card can handle two independent radio channels Channel A is usually supplied with built in radio or external radio for special request Channel B only can be used with an
2. power cable 18 VDC power supply unit Battery connector cable without battery e User Manual e Programming Manual e Installer Manual Before mounting the device to its operation environment receiver test is recommended For this connect the external power supply to the PWR card 16 5 V AC terminals and the battery to the BATTERY 1 and BATTERY 1 connectors The receiver executes a self test after connecting the power supply and it detects system components optional LC line cards IP cards RC radio receiver card After this operation the event list can be seen on LCD display Note Battery usage is only recommended at BATTERY 1 connector In special cases usage without main power it is possible to use two batteries another battery on BATTERY 2 connector to provide continuous operation but is not recommended for long term usage Note Battery charging voltage can be only measured if the battery is connected 5 4 INSTALLATION Mounting the receiver unit ENIGMA Il is manufactured in a 3HE height 19 table housing In addition it can be mounted to a standard 19 rack case by means of the holes in front board Note The table stands might be folded up in case of installation to a rack case Note LCD display is planned to be well seen in table usage If the receiver is installed over the eye level it is recommended to turn a bit downward for better readability Printer connection Any type of parallel pr
3. ENIGMA II Monitoring Receiver Installer Manual 11 02 2014 CONTENT INTRODUC TON roller RR LA 3 2SYSTEMSTRUCFURE aLaaa ore 3 DA GPM cardoso Sr Sede anid e aaa 3 2 2 LC telephone Ime card opuondl soll eeeeae 4 2 3 RC radio receiver card OPtOHal 2 alice 4 ZA PWR power supply card lunotto 4 gt o lP card optional ironinen nip awd e iE cba a AE T eves ned nce a EE a oa EE 4 2 6 Monitoring software COMPALbility csrcriialionadiolaea alain 5 J FIRST STEPS e a a ia 5 4 INSTALLATION spalle iaia 6 Mou ting th receiver ns riale erica ne E se 6 Pinter CONNECT RE ne a ee One 6 PE Conero 6 CPM central processing card backside connectors 7 PWR power supply card backside connectors ii 8 LC telephone line card backside connectors optional 9 RC radio receiver card backside connectors optional 10 IP Ethernet receiver card backside connectors optional 11 Card installation and replacement nee reed 12 ISTECHNICAL DATA Lula 12 1 INTRODUCTION Thank you for choosing our product This modern and reliable monitoring receiver not only guarantees the highest level of security but also it is a useful colleague in the life of every monitoring company because of its user friendly handling and intelligent functions To use the highest range of provided functions please
4. an be connected to external connectors In case of main power trouble battery powered operation is switched automatically The capacity of batteries should be between 7 Ah and 15 Ah The PWR continuously check the state of main power and batteries and it reports the status to CPM unit 2 5 IP card optional Receiver has 8 slots to connect IP Ethernet based receiver cards IP cards can work in standalone mode they control individually the incoming events through Ethernet line Then they forward events to central processing unit through internal receiver bus IP card gives extended range in IP receiving functions comparing to CPM Additionally it provides possibility to connect the system to a secondary Internet provider 4 2 6 Monitoring software compatibility The device can work with the most generally used monitoring software packages During development the receiver has been tested with the following software packages e ALARM SYS recommended SIMS MYMAS SURGARD receiver should be chosen for SIMS MYMAS or other software types 3 FIRST STEPS Please unpack the device carefully and please check is there any damage on that caused by transport If there is any obvious damage do not switch on the device please call the distributor The basic package contains the following units e ENIGMA Il monitoring receiver 1 CPM card 1 PWR card e RS232 cable for PC connection e USB cable for PC connection e 16 5 VAC transformer and
5. et connector for IP monitoring and for remote programming USB A Default communication port for PC connection if there is no serial port USB B Reserve communication port for PC connection 12 V Power connector for control functions Up to 500 mA load capacity PGM 1 PGM 2 For future usage BUZZER To connect external buzzer intermittent shortcut with GND during internal buzzer activation if the internal buzzer is enabled Up to 50 mA load capacity TAMPER Works as NO tamper switch if the tamper function is enabled EXT ACK Works as external acknowledge button shortcut with GND means manual acknowledge same way as ENTER button if external acknowledge function is enabled Note Install a 10 K pull up resistor between EXT ACK and 12 V terminals GND Common GND connector for control functions 7 PWR power supply card backside connectors For device installation connect the external voltage to the PWR card 16 5 V AC terminals and the battery to the BATTERY 1 and BATTERY 1 connectors The receiver executes a self test after connecting the power supply and it detects system components optional LC line cards RC radio receiver card IP card After this operation the event list can be seen on LCD display Note Battery usage is only recommended at BATTERY 1 connector In special cases usage without main power it is possible to use two batteries another battery on BATTERY 2 for c
6. external radio unit If the channel A is supplied with built in radio RTX 2U2 only the antenna should be connected to ANT connector Pay attention for using UHF antenna with suitable end of line resistor 50 ohm and the RF cabling should have minimal loss Note If you want to use channel B with external radio unit please contact your distributor a C2 RSP Radio serial port for programming without x II CPM radio repeater stations and for debugging a O RadioCard 2 ANT Antenna connector for built in radio units ANT channel A si Note Always choose the appropriate antenna RADIO 2 according to the installation site of the receiver RADIO 2 External radio connector for channel B RADIO 1 For special request channel A might be supplied with external radio unit IP Ethernet receiver card backside connectors optional IP receiver cards are able to receive events through Ethernet network IP card has extended IP receiving functions compared to CPM unit in main receiver Connect the Ethernet network cable into the Ethernet slot on the receiver card backside If it is required the IP card can be connected directly to monitoring PC through USB connector on receiver backside LAN 100 Mbit Ethernet network connector USB To connect monitoring PC if it is required 11 Card installation and replacement Receiver switch off is not required during card rep
7. inter can be used with Centronics connector Connect the cable of the printer to the LPT port of the CPM unit Note In view of the default usage of the device it is recommended to use matrix printer as against laser ink jet printers for event print PC connection For the connection to monitoring software connect the receiver COM A USB A port to the serial port USB port of the monitoring PC Use the cable provided in receiver package If the cable length is not enough you can use USB expander cable or RS232 expander cable COM A 2 3 5 pin PC 9 pin 3 2 5 pin With this you may have up to 10 12 m distance between receiver unit and monitoring PC Note COM A and USB A ports are equivalent as the COM B and USB B ports Do not connect devices at the same time to COM A and USB A ports If it is possible always recommended to use COM A as against USB A Note If the A serial port of the receiver has any trouble B port can work as a replacement For this some small configuration steps are required which can be found in Programming Manual CPM central processing card backside connectors O RESET o CPM 2 COMA LPT MB Da 12 V PGM 1 PGM 2 BUZZER TAMPER EXT ACK GND RESET Hardware reset button COM A Default communication port for PC connection COM B Reserve communication port for PC connection or for external receiver LPT Parallel printer port TCP IP Ethern
8. lacement Unscrew the two four fixing screws then pull the card carefully with a firm action New card installation is the same only in opposite sequence Before installing new LC RCM IP card please remove the metal cover from the card position CPM PWR RCM cards have fix position LC IP card can be mounted into 1 8 slots starting from slot 1 if possible Note Do not forget to apply set again previous settings before change in new cards Note If there is any malfunction after card replacement please restart the device with F3 UTIL F3 RESET F3 RESET buttons 5 TECHNICAL DATA Product ENIGMA II 18 Vdc 2 A main or 16 5 Vac 30 VA main 12 Vdc 7 Ah battery about 500 mA Power supply Maximum current consumption depends on configuration Event buffer up to 2000 events Monitored IP devices up to 255 accounts Operating temperature 10 C 30 C 40 relative humidity Sizes W L H 485 x 220 x 135 mm Weight 5200 g
9. ontinuous operation but is not recommended for long term usage Note Use only the power supply 18 VDC transformer in receiver package or a replacement transformer with at least 50VA 16 5 VAC capacity BAT 3 15 A Fuse to protect battery circuit AC 3 15 A Fuse to protect AC power supply circuit C AL BATTERY 1 Primary battery connector 7 15 Ah sip BATTERY 2 Secondary battery connector 7 15 Ah C 16 5 V AC Main power supply connector 18 VDC power AC 3 15 A supply transformer in receiver package or at least 50 VA 16 5 VAC capacity replacement transformer GROUND Standard M5 nut for grounding power supply unit It is not allowed to use the receiver without 185 vac sartery 1 BATTERY 2 proper grounding Note To provide appropriate protection against electrostatic and electromagnetic interferences the device housing should be grounded properly Grounding of housing and grounding of telephone line cards can be connected only at the common ground point at least 2 m distance between each card grounding point M5 nut terminals Grounding is essential for flash of lighting and over potential protection absence of proper grounding may cause communication problems as well Note Never connect grounding point to receiver GND terminal it may cause damage 8 LC telephone line card backside connectors optional LC line card is suitable to receive analog PSTN
10. read carefully the nstaller Manual For the confident programming and secure usage please keep all warnings in nstaller Manual with highly focusing to security directions 2 SYSTEM STRUCTURE ENIGMA Il monitoring receiver provides complex and reliable solution to build up a modern monitoring station The device can receive signals from alarm control panels through IP network telephone line and radio channel Due to the universal operation the device can receive all standard and most of the non standard signals from alarm control panels and communicators With combination of an appropriate PC based monitoring software it guarantees not only reliable signal transmission but also easy to use operator interface The system consists of the following devices 2 1 CPM card Central processing card CPM which controls the operation of the receiver CPM contains two serial ports respectively 2 high speed USB ports one Ethernet port and one parallel printer port CPM card can store up to 2000 events in its non volatile memory If the connection fails with monitoring computer the receiver stores events in its own memory and all events will be sent automatically when the connection is restored CPM controls the graphical LCD display as well where received events can be seen and basic settings can be done 2 2 LC telephone line card optional Receiver has 8 slots to connect LC telephone line cards LC line cards can monitor one
11. telephone line Each telephone line card have memory to store up to 500 events or caller ID Caller ID function is built in the caller telephone number is stored and can be transmitted to monitoring computer Line cards support two way audio communication also Line cards are continuously monitored by CPM All line card troubles are displayed immediately at LCD display and transmitted to monitoring computer The line card monitors the connection with CPM as well if it detects trouble automatically switches to standalone operation mode In this case it continues event receiving but stores them in its own memory All received events will be sent automatically to CPM when the connection is restored 2 3 RC radio receiver card optional The optional RC radio receiver card works as a special line card in the system it provides event receiving through UHF radio 440 450MHz RC card can handle two independent radio channels which are displayed as line card A and B in the system Event management and CPM monitoring way is similar to LC line cards In standalone mode the RC card can store up to 500 events which will be sent automatically to CPM when the connection is restored 2 4 PWR power supply card PWR power supply card ensures voltage for all cards in the system The input of PWR requires 16 5 VAC 18 VDC which is generated by an external transformer unit power supply unit PWR has got battery charging circuit batteries c
Download Pdf Manuals
Related Search
Related Contents
Multiquip HHXG5 SONAR User Manual Model 8682/8682-BAC SureFlow Adaptive Offset Controller User`s Manual ASUS UX301LA User's Manual MINICOMPONENTE HP OpenVMS Migrating an Application from OpenVMS VAX to 使用方法 製品情報について KRS-25xxHV シリーズ対応 取扱説明書 名称未設定-1.indd Copyright © All rights reserved.
Failed to retrieve file