Home

Dr.Web Security Space - FTP Directory Listing

image

Contents

1. Tools for Network Attacks e Nuke tools for network attacks on known vulnerabilities of operating systems leading to abnormal shutdowns of the attacked system e DDoS agent program for performing a DDoS attack Distributed Denial Of Service e FDoS synonym Flooder Flooder Denial Of Service programs for performing malicious actions in the Internet which use the idea of DDoS attacks in contrast to DDoS when several agents on different computers are used simultaneously to attack one victim system an FDoS program operates as an independent self sufficient program Flooder Denial of Service Script Viruses Prefixes of viruses written in different scrip languages e VBS Visual Basic Script e JS Java Script e Wscript Visual Basic Script and or Java Script e Perl Perl e PHP PHP e BAT MS DOS command interpreter Malicious Programs e Adware an advertising program e Dialer a dialer program redirecting modem calls to predefined paid numbers or paid resources e Joke a joke program e Program a potentially dangerous program riskware e Tool a program used for hacking hacktoo Miscellaneous e Generic this prefix is used after another prefix describing the environment or the development method to name a typical representative of this type of viruses Such virus does not possess any characteristic features such as text strings special effects etc whic
2. ax 1 Introduction While performing any of the abovementioned checks the Dr Web anti virus solutions use the most recent information about known malicious software As soon as experts of Doctor Web Virus Laboratory discover new threats the update for virus signatures behavior characteristics and attributes is issued In some cases updates can be issued several times per hour Therefore even if a brand new virus passes through the Dr Web resident guards and penetrates the system then after an update the virus is detected in the list of processes and neutralized 10 Ta J i ax 2 System Requirements 11 2 System Requirements Before installing Dr Web e Remove any anti virus software from your computer to prevent possible incompatibility of resident components e If you install Dr Web Firewall uninstall all other firewalls from your computer e Install all critical updates released for your operating system If the operating system is no longer supported then upgrade to a newer operating system Dr Web can be installed and run on a computer which meets the following minimum requirements CPU Operating system Free RAM Hard disk space Resolution Other An i686 compatible processor For 32 bit platforms e Windows XP with Service Pack 2 or higher e Windows Vista with Service Pack 2 or higher e Windows 7 e Windows 8 e Windows 8 1 e Windows 10 For 64 bit platforms e Windows Vista with Service Pack
3. Doctor Web trial user 115196679 Activation date 03 10 2014 14 12 Expiration date 02 11 2014 14 12 Remain 10 days Data Loss Prevention Anti Virus Network Quarantine Manager Support You can get a new license for any Dr Web product at any time Get new license My Dr Web License agreement Obtaining key file To start the registration procedure for receiving the key file from Doctor Web servers click Get new license and select from Internet in the drop down menu That launches Registration Wizard that will guide you through obtaining the key file To enable operation of Dr Web install the key file on the system My Dr Web link opens your personal page of the Doctor Web official website with the default Internet browser This page provides you with information on your license including usage period and serial number and allows to renew the license contact technical support and so on cick to delete the selected license by removing the corresponding key file The current license cannot be deleted A You can delete license only in the administrator mode This button is not available in user mode To enable operation of Dr Web install a Dr Web key file on the system The key files received during installation or within the product distribution kit are installed automatically Ta N ax 6 Tools By default the key file is located in the Dr Web installation folder Dr Web verifies the file regularly
4. Ta AN ax Appendices Stealth viruses perform certain actions to disguise their activity and thus conceal their presence in an infected object Such viruses gather the characteristics of a program before infecting it and then plant these dummy characteristics which mislead the scanner searching for modified files Viruses can also be classified according to the programming language in which they are written in most cases it is assembler high level programming languages scripting languages etc or according to the affected operating systems Computer Worms Worms have become a lot more widespread than viruses and other malicious programs recently Like viruses they are able to reproduce themselves and spread their copies but they do not infect other programs A worm infiltrates the computer from the worldwide or local network usually via an attachment to an email and distributes its functional copies to other computers in the network It can begin distributing itself either upon a user s action or in an automatic mode choosing which computers to attack Worms do not necessarily consist of only one file the worm s body Many of them have an infectious part the shellcode which loads into the main memory RAM and then downloads the worm s body as an executable file via the network If only the shellcode is present in the system the worm can be rid of by simply restarting the system at which the RAM is erased and
5. Advanced No restrictions Change Buses User defined Change Device and bus classes To block access to specified device or bus classes enable the appropriate option Click the Change button to make a list of such objects If you want to keep access to some particular devices add them to the white list To add the device to the white list make sure that it is connected to the computer and click the Add button Then select the wanted object after viewing the advanced device information in the bottom field if necessary You will be able to view this information after adding the device to the white list too 55 Sgn oF 10 Main Settings 10 8 Advanced On this page you can configure additional settings Main Advanced Language qs Update Network Log Self Protection default settings Change Dr Web Cloud Quarantine Anti Virus Network default settings Devices Advanced To set another program language select it in the corresponding drop down list New languages are automatically added to the list Thus it contains all localization languages that are currently available for the Dr Web graphical interface Log settings To configure log settings click the corresponding Change button By default size of a log file is restricted to 10 MB If the log file size exceeds the limit the content is reduced to e Specified size if the current session information does not exceed the limit e
6. It is unauthorized monitoring of data and traffic flow performed by a packet sniffer a special type of non malicious program which intercepts all the network packets of the monitored domain Spoofing a type of network attack when access to the network is gained by fraudulent imitation of connection Phishing an Internet fraud technique which is used for stealing personal confidential data such as access passwords bank and identification cards data etc Fictitious letters supposedly from legitimate organizations are sent to potential victims via spam mailing or mail worms In these letters victims are offered to visit phony web sites of such organizations and confirm the passwords PIN codes and other personal information which is then used for stealing money from the victim s account and for other crimes Vishing a type of Phishing technique in which war dialers or VoIP is used instead of emails Actions Applied to Threats There are many methods of neutralizing computer threats Products of Doctor Web combine these methods for the most reliable protection of computers and networks using flexible user friendly settings and a comprehensive approach to security assurance The main actions for neutralizing malicious programs are 1 Cure an action applied to viruses worms and Trojans It implies deletion of malicious code from infected files or deletion of a malicious program s functional copies as well as the rec
7. disabled the rule or changed the work mode the process will be blocked till its next attempt to establish connection When an application is deleted from your computer the related rules are not automatically deleted You can delete them manually by clicking Remove unused rules in the shortcut menu of the list In the New application rule set or Edit rule set window you can configure access to network resources as well as enable or disable launch of other applications 81 Ta J 1 ax 13 Protection components 82 To open this window in the Firewall settings window select the Applications page and click Create or select an application and click Edit When Firewall is operating in learning mode you can start creating a new rule directly from the windows with notification on an unknown connection attempt Launching other applications To enable or disable launch of other applications in the Launching network applications drop down list select one of the following e Allow if you want to enable the application to run other processes e Block if you want to disable the application to run other processes e Not specified if you want to use the settings specified for the selected operation mode of Firewall Access to network resources 1 Specify one of the following modes to access network resources e Allow all all connections are allowed e Block all all connections are blocked e Not specif
8. template example com test22 and so on Your input may be unified 2 Click The address will appear in the list 3 To add other websites repeat steps 1 to 2 To remove an address from the list select the corresponding item and click 12 2 Files and Folders In this section you can manage the list of files and folders that are excluded from SpIDer Guard scanning You can exclude the anti virus quarantine folders working folders of some programs temporary files paging file and so on The default list is empty Add particular files and folders to exclusions or use masks to disable scanning of a certain group of files Configuring list of exclusions 1 To add a file or folder to the exclusion list do one of the following e To add an existing file or folder click In the open window click Browse and select it in the standard dialog window You can enter the full path to the file or folder or edit the path in the field before adding it to the list e To exclude all files or folders with a particular name enter the name without path e To exclude a group of files or folders enter the mask of their names 62 A AN v Aq A Y 12 Exclusions 63 2 Click OK The file or folder will appear in the list 3 To list other files and folders repeat steps 1 to 2 To remove a file or folder from the list select the corresponding item and click Examples e C folder or C folder excludes
9. 2 or higher e Windows 7 e Windows 8 e Windows 8 1 e Windows 10 You may need to download and install certain system components from the Microsoft official website If necessary the program will notify you about the Dr Web components required and provide download links Minimum 512 MB 1 GB for Dr Web components Files created during installation will require additional space Recommended minimum screen resolution is 800x600 For the Dr Web for Outlook extension one of the following Microsoft Outlook clients from the Microsoft Office package is required e Outlook 2000 Outlook 9 e Outlook 2002 Outlook 10 or Outlook XP e Office Outlook 2003 Outlook 11 e Office Outlook 2007 e Office Outlook 2010 Office Outlook 2013 Ta 1 aX 3 Installing the program 12 3 Installing the program Before installing Dr Web note the system requirements and do the following e install all critical updates released by Microsoft for the OS version used on your computer they are available on the company s update site at http windowsupdate microsoft com e check the file system with system utilities and remove the detected defects e close all active applications Remove any anti virus software and firewalls from your computer to prevent possible incompatibility of resident components Ta J i ax 3 Installing the program 13 3 1 Installation Procedure A Only a user with administrative priv
10. Do not edit or modify the key file to avoid its corruption If no valid key file is found Dr Web components are blocked License Manager can display a notification above the SpIDer Agent icon in the notification area If necessary you can configure desktop and email notifications 6 2 Data Loss Prevention You cannot change data loss prevention parameters or restore files from copies in user mode For this actions switch to administrator mode To protect important files from being changed by malicious software enable the Data Loss Prevention function With this function you can make copies of files that reside in the specified folders Click the Select files and directories to protect link to specify the objects for which protected copies will be created You may change the objects list at any time You may also specify the disk to store copies and the frequency of creating copies After the chosen interval Dr Web will inspect the specified objects for changes and create a copy if any change will have been made You may also delete the copies to free up some disk space deleting the copies will not affect the original files and block creating the copies while working on battery mode Tools Data loss prevention Enable the option to automatically create copies of your files to prevent their License Manager unwanted modification If any threat causes corruption of your files you will be able to restore information from their prote
11. FreeBSD FreeBSD programs e SunOS SunOS Solaris programs e Symbian Symbian OS mobile OS programs Note that some viruses can infect programs of one system even if they are designed to operate in another system Macrovirus Prefixes The list of prefixes for viruses which infect MS Office objects the language of the macros infected by such type of virus is specified e WM Word Basic MS Word 6 0 7 0 e XM VBA3 MS Excel 5 0 7 0 e W97M VBA5 MS Word 8 0 VBA6 MS Word 9 0 e X97M VBA5 MS Excel 8 0 VBA6 MS Excel 9 0 e A97M databases of MS Access 97 2000 112 Ta AN ax Appendices PP97M MS PowerPoint presentations 097M VBA5 MS Office 97 VBA6 MS Office 2000 this virus infects files of more than one component of MS Office Development Languages The HLL group is used to name viruses written in high level programming languages such as C C Pascal Basic and others HLLW worms LLM mail worms LO viruses overwriting the code of the victim program LP parasitic viruses LC companion viruses Pe Ee at The following prefix also refers to development language Java viruses designed for the Java virtual machine Trojan Horses Trojans Trojan a general name for different Trojan horses Trojans In many cases the prefixes of this group are used with the Trojan prefix PWS password stealing T
12. NB do not backup cured or deleted files Option is disabled by default NI X limits usage of system resources at scanning and priority of the scanning process By default unlimited NOREBOOT cancel system reboot or shutdown after scanning For Scanner only NT check NTFS streams Option is enabled by default OK display the full list of scanned objects and mark clean files with Ok Option is disabled by default P lt prio gt priority of the current scanning task 0 the lowest L low N normal Default priority H high M maximal PAL lt level gt maximum pack level If a nesting level is greater than the specified value Scanner proceeds unpacking and scanning the archive until this limit is exceeded The nesting level is 1000 by default QL list files quarantined on all disks For Console Scanner only QL lt logical_drive_name gt list files quarantined on the specified drive letter For Console Scanner only QNA double quote file names QR d p delete quarantined files on drive lt d gt logical_drive_letter that are older than lt p gt number days If lt d gt and lt p gt are not specified all quarantined files on all drives are deleted For Console Scanner only 101 Ta J 1 ax Appendices 102 QUIT terminate Dr Web Scanner once scanning completes whether the detected threats are neutral
13. Note that you will be returned to the user mode in 15 minutes after switching to the administrator mode If you Ta i ax 5 Getting Started 23 are still configuring the settings when this time expires you will be returned to the user mode after closing the settings window Statistics ally Opens statistics on the components operations in the current session including the number of scanned infected and suspicious objects actions performed and so on Settings or Opens a window with access to the main settings protection components settings Parental Control and exclusions To access the component settings and open your personal webpage My Dr Web you also need to enter the password if you enabled Protect Dr Web settings by password option on the Settings window If you forgot your password for the product settings contact technical support Ta J i ax 5 Getting Started 24 5 1 How to Test Anti virus The EICAR European Institute for Computer Anti Virus Research test file helps to test performance of anti virus programs that detect viruses using signature analysis For this purpose most of the anti virus software vendors generally use a standard test com program This program was designed specially so that users could test reaction of newly installed anti virus tools to virus detection without compromising security of their computers Although the test com program is not actually a virus it is treated
14. Restart your computer after the installation is complete Ta J 1 ax 3 Installing the program 17 3 2 Removing or changing the program A After you uninstall Dr Web your computer will not be protected from viruses and other malware 1 To uninstall Dr Web or change its configuration by adding or removing individual components select depending on the operating system e For Windows XP depending on the presentation of the Start menu Start menu Start gt Control Panel Add or Remove programs a Classic Start menu Start Settings Control Panel Add or Remove programs e For Windows Vista depending on the presentation of the Start menu Start menu Start gt Control Panel then depending on the Control Panel view o Classic view Programs and Features o Control Panel Home Programs Programs and Features e Classic Start menu Start Settings Control Panel Add or Remove programs e For Windows 7 click Start gt Control Panel then according to the Control Panel view Small large icons Programs and Features Category Programs Uninstall a program e For Windows 8 and Windows 8 1 open Control Panel in any convenient way for example right click the bottom left corner and select the Control Panel item in the shortcut menu According to the selected View option for the Control Panel click a Small large icons Programs and Features Category Programs Uninsta
15. Size of the current session if the session information exceeds the limit User Manual 56 Ta 1 ax 10 Main Settings 57 Detailed logging Enabling this option may adversely affect your computer performance SpIDer Guard Firewall SpIDer Mail Dr Web Update SpIDer Gate Dr Web Services Advanced Create memory dumps at scan errors OK Cancel By default the standard logging mode is enabled and the following information is logged SpIDer Guard Time of updates and SpIDer Guard starts and stops virus events names of scanned files names of packers and contents of scanned complex objects archives email attachments file containers It is recommended to use this mode to determine the most frequent objects scanned by SpIDer Guard If necessary you can add these objects to the list of exclusions in order to increase computer performance SpIDer Mail Time of updates and SpIDer Mail starts and stops virus events connection interception settings names of scanned files names of packers and contents of scanned archives It is recommended to use this mode when testing mail interception settings SpIDer Gate Time of updates starts and stops of SpIDer Gate virus events connection interception settings names of scanned files names of packers and contents of scanned archives It is recommended to use this mode for reception of more detailed information on the checked up objects and work of the HTT
16. Switches begin with the forward slash character and are separated with blanks as other command line parameters The switches are listed alphabetically Scanner and Console Scanner Parameters AA apply actions to detected threats automatically For Scanner only AC scan installation packages Option is enabled by default AFS use forward slash to separate paths in an archive Option is disabled by default AR check archives Option is enabled by default ARC lt ratio gt maximum compression level If the compression ratio of the archive exceeds the limit Scanner neither unpacks nor scans the archive By default unlimited ARL lt evel gt maximum archive nesting level By default unlimited ARS lt size gt maximum archive size If the archive size exceeds the limit scanner neither unpacks nor scans the archive in KB By default unlimited ART lt size gt minimum size of a file inside an archive beginning from which compression ratio check is performed in KB By default unlimited ARX lt size gt maximum size of a file inside an archive that is checked in KB By default unlimited BI show information on virus databases Option is enabled by default DR scan folders recursively scan subfolders Option is enabled by default lt engines gt perform scanning in specified number of threads FAST _ perform an express scan of the system For
17. be typical for the virus code itself and vice versa that are extremely rare in viruses Each attribute has a weight coefficient which determines the level of its severity and reliability The weight coefficient can be positive if the corresponding attribute is indicative of a malicious code or negative if the attribute is uncharacteristic of a computer threat Depending on the sum weight of a file the heuristics analyzer calculates the probability of unknown virus infection If the threshold is exceeded the heuristic analyzer generates the conclusion that the analyzed object is probably infected with an unknown virus The heuristics analyzer also uses the FLY CODE technology which is a versatile algorithm for extracting files The technology allows making heuristic assumptions about the presence of malicious objects in files compressed not only by packagers Dr Web is aware of but by also new previously unexplored programs While checking packed objects Dr Web anti virus solutions also use structural entropy analysis The technology detects threats by arranging pieces of code thus one database entry allows identification of a substantial portion of threats packed with the same polymorphous packager As any system of hypothesis testing under uncertainty the heuristics analyzer may commit type I or type II errors omit viruses or raise false alarms Thus objects detected by the heuristics analyzer are treated as suspicious 9 Ta J i
18. control access to network than the application level filtering Firewall uses the following predefined rule sets e Default Rule this rule set is used by default for new network interfaces e Allow All this rule set configures the component to pass through all packets e Block All this rule set configures the component to block all packets For fast switching between filtering modes you can create custom sets of filtering rules To set rule sets for network interfaces In the Firewall settings window select Interfaces and click Configure On this page you can e Configure sets of filtering rules by adding new rules modifying existing ones or deleting them e Configure additional filtering settings To configure rule sets Do one of the following e To add a new set of rules click Create e To edit an existing set of rules select the rule set in the list and click Edit e To add a copy of an existing set of rules select the rule set and click Copy The copy is added after the selected rule set e To delete a selected rule set click Delete Ta 1 ax 13 Protection components 85 To configure additional settings In the Packet filter settings window use the following options Use TCP stateful packet filtering Management of fragmented IP packets Rule Sets Select this check box to filter packets according to the state of existing TCP connections Firewall will block packets that do
19. increasing speed of your Internet connection However frequent scans also increase processor load You can select the type of HTTP traffic to check By default only incoming traffic is scanned At that the specified actions white list and excluded applications also have an effect Ta J i ax 13 Protection components 13 3 SpIDer Mail SpIDer Mail is an anti virus mail scanner that installs by default and monitors data exchange between mail clients and mail servers made via POP3 SMTP IMAP4 or NNTP IMAP4 stands for IMAPv4rev1 protocols SpIDer Mail uses Dr Web Anti spam technologies which allows to scan mail for spam messages The default settings are optimal for beginners provide maximum protection and require minimum user interference However SpIDer Mail may block some options of mail programs for example sending a message to multiple addresses might be considered as mass distribution incoming mail is not scanned for spam useful information from safe text part of infected messages becomes unavailable in case of automatically deletion Advanced users can configure mail scanning settings and reaction of SpIDer Mail to various virus events Mail Processing Any incoming messages are intercepted by SpIDer Mail before they are received by mail clients Messages are scanned for viruses with the maximum possible level of detail If no viruses or suspicious objects are found messages are passed on to the mail pro
20. on the issues listed above By default these notifications are enabled Select to be notified on the following minor issues e Successful update e Update failures e Expiration of the time limit set for Internet use e Blocked URLs e Blocked attempt to access a protected object Clear this check box if you do not want to be notified on the issues listed above By default these notifications are disabled Notifications on the following issues are not included in any of the specified groups and are always displayed to the user e priority updates installed and restart is required e request for allowing a process to modify an object e successful connection to a remote computer in the Anti virus Network e demo period is activated and we recommend to purchase a license e the current license is blocked Ta N ax 10 Main Settings 10 2 Update On this page you can configure protection of Dr Web itself You can also configure update parameters such as components that should be updated an updating source update period proxy server and update mirror Main Update Update frequency Notifications 30 minutes recommended Y Update Update source Network Doctor Web servers recommended Change Self Protection Dr Web Cloud Anti Virus Network Devices Advanced Advanced settings General update settings Update frequency Specify the frequency to check for updates The default value 30 minutes
21. only for users with administrative rights For Windows Vista and later operating systems after clicking Log e If UAC is enabled administrator is requested to confirm program actions user without administrative privileges is requested to enter accounting data of system administrator e If UAC is disabled administrator can change program settings user does not have the permission change program settings To view program log To open the text log click Show in folder The folder where the text log is located opens 13 6 5 Statistics In the Microsoft Outlook mail application on the Tools Options Dr Web Anti virus page for Microsoft Outlook 2010 in the Files Options Add ins section select Dr Web for Outlook and click the Add in Options button statistic information about total number of objects which have been checked and processed by the program is listed These scanned objects are classified as follows Checked total number of checked messages Infected number of messages with viruses Suspicious number of messages presumably infected with a virus upon a reaction of the heuristic analyzer Cured number of objects successfully cured by the program Not checked number of objects which cannot be checked or check of which failed due to an error Clear number of messages which are not infected Then the number of processed objects is specified Moved to quarantine number o
22. options e The Infected drop down list sets the reaction to the detection of a file infected with a known and presumably curable virus e The Not cured drop down list sets the reaction to the detection of a file infected with a known incurable virus and in case an attempt to cure a file failed e The Suspicious drop down list sets the reaction to the detection of a file presumably infected with a virus upon reaction of the heuristic analyzer e Adware e Dialers e Jokes e Hacktools e Riskware In the Malware section set a reaction to detection of unsolicited software of the following types e The If checked failed drop down list allows to configure actions if the attachment cannot be checked e g if the attached file is corrupted or password protected The Check archives recommended check box allows to enable or disable check of attached archived files Set this check box to enable checking clear this check box to disable For different types of objects actions are specified separately Ta AN ax 13 Protection components 90 The following actions for detected virus threats are available Cure only for infected objects instructs to try to restore the original state of an object before infection As incurable only for infected objects means that the action specified for incurable objects will be performed Delete delete the object Move to quarantine move the object to the spec
23. specified at the start or at the end of an address only The at sign is mandatory e To ensure delivery of messages sent from any email address within a certain domain specify an asterisk instead of the username in the address For example if you enter example net messages from all senders within the example net domain will be delivered without scanning e To ensure delivery of messages sent from email address with a certain user name from any domain specify an asterisk instead of the domain name in the address For example if you want to receive messages from all senders with the someone mailbox enter name Black List If the sender s address is on the black list the message will be automatically regarded as spam Details e To add a definite sender enter the full email address for example spam spam com All messages received from these addresses will be automatically regarded as spam Each list item can contain only one address or address mask e To add a group of sender addresses enter the mask that determines their names The mask defines a template for an object definition It may contain regular characters from email addresses and a special asterisk character which replaces any including an empty one sequence of characters To regard as spam messages sent from any email address within a domain use an asterisk character instead of the username in the address For example if you enter spam com
24. switches to using the new key file 4 3 Registration Wizard SpIDer Agent checks whether you have a key file If no key file is found you are prompted to obtain a key file on the Internet A key file can be obtained during an installation procedure For this select Receive key file during installation on step 5 of installation procedure and activation of the license or demo period will start You can also obtain a key file by starting activation of the license or demo period after the product is installed on your system For that do one of the following e Click the SpIDer Agent icon amp in the notification area and select License e In the License Manager window click Get new license and select from Internet After activation is started the Registration Wizard window opens To activate the license you need to enter the registration serial number supplied to you when purchasing Dr Web 20 Ta 2 N ys You can activate a demo period to evaluate operation of Dr Web Security Space e For 3 months For that register on the website and receive a serial number After you complete the questionnaire a serial number required to activate the demo period for 3 months is sent to the specified email address e For 1 month For that purpose no serial number is required and no registration data is requested 4 3 1 Starting activation The first window prompts you to select one of the following activation method
25. the corresponding message displays where the license validity period or demo period is specified Click Finish to proceed to updating the virus databases and other package files This procedure does not require user intervention If activation failed an error message displays Click Network settings to adjust Internet connection parameters or click Repeat to correct invalid data 4 Licensing 21 Ta J i ax 5 Getting Started 22 5 Getting Started After Dr Web is installed the SpIDer Agent amp icon is added to the notification area If SpIDer Agent is not running select the Dr Web application group on the Windows Start menu and then select SpIDer Agent The SpIDer Agent icon indicates the status of Dr Web e amp All necessary components are running and protect your computer e Dr Web Self protection or an important component such as SpIDer Guard or Firewall is disabled which compromises security of Dr Web and your computer Enable Self protection or the component e Dr Web components are expected to start after the operating system start up process is complete thus wait until the components start or an error occurred while starting one of the main Dr Web components and your computer is at risk of virus infection Check that you have a valid key file and if required install it Various notifications may appear over the SpIDer Agent amp it configured To open the SpIDer Agent menu click th
26. them unnecessarily Protection Scan options om 010 ne nts Check traffic in IM clients On _ This option enables checking of URLs and data transmitted by instant messaging clients such as Mail RU Agent ICQ and Jabber clients SpIDer Guard SpIDer Gate SpIDer Mail Blocking parameters Block URLs listed due to a notice from copyright owner Off Cm Block not recommended websites Preventive Protection On a Anti spam Firewall Advanced settings 69 Ta J N ax 13 Protection components IM Clients Check In the Scan options group you can enable check of URLs and data transmitted by instant messaging clients Mail RU Agent ICQ and clients using the Jabber protocol Only incoming traffic is checked Option is enabled by default Links transmitted in messages are checked according to the SpIDer Gate settings links to the websites known as infection sources are blocked automatically links to the websites that are not recommended for visiting or URLs due to a notice from copyright owner are blocked only if the corresponding options are enabled At that white list and list of excluded applications also have an effect Files transmitted by instant messaging clients are also checked When a threat is detected file transmission is blocked if the corresponding setting is enabled on the Block programs page Viruses are blocked automatically if the Check traffic in IM clients option is enabled Bloc
27. to the Internet Changes to this file may indicate virus infection Block applications from writing on disks by sectors avoiding the file system Block applications from loading new or unknown drivers Other options allow protection of the following registry branches from modification in the system profile as well as in all user profiles File Execution Options e Software Microsoft Windows NT CurrentVersion Image File Execution Options User Drivers e Software Microsoft Windows NT CurrentVersion Drivers32 e Software Microsoft Windows NT CurrentVersion Userinstallable drivers Winlogon registry keys e Software Microsoft Windows NT CurrentVersion Winlogon Userinit Shell UIHost System Taskman GinaDLL Winlogon notifiers e Software Microsoft Windows NT CurrentVersion Winlogon Notify Windows registry startup keys e Software Microsoft Windows NT CurrentVersion Windows AppInit_DLLs LoadAppInit_DLLs Load Run IconServiceLib Executable file associations e Software Classes exe pif com bat cmd scr Ink keys e Software Classes exefile piffile comfile batfile cmdfile scrfile Inkfile keys Software Restriction Policies SRP e Software Policies Microsoft Windows Safer Browser Helper Objects for Internet Explorer BHO e Software Microsoft Windows CurrentVersion Explorer Browser Helper Objects Autorun of programs e Software Microsoft Windows CurrentVersion Run e Software Microsoft Windows CurrentVer
28. you can increase protection by selecting the Medium mode In this mode access to the critical objects which can be potentially used by malicious software is blocked Using this mode may lead to compatibility problems with legitimate software that uses the protected registry branches When required to have total control of access to critical Windows objects you can select the Paranoid mode In this mode Dr Web also provides you with interactive control over loading of drivers and automatic running of programs With the User defined mode you can set a custom protection level for various objects Ta N ax G 13 Protection components 98 Integrity of running applications Integrity of user files HOSTS file Low level disk access Drivers loading Critical Windows objects This option allows detection of processes that inject their code into running applications It indicates that the process may compromise computer security Processes that are added to the exclusion list of SpIDer Guard are not monitored This option allows detection of processes that modify user files with the known algorithm which indicates that the process may compromise computer security Processes that are added to the exclusion list of SpIDer Guard are not monitored To protect your data from modification you can enable creation of protected copies that contain important data The operating system uses the HOSTS file when connecting
29. 1 Notifications 10 2 Update 10 3 Network 10 4 Self protection 10 5 Dr Web Cloud 10 6 Anti virus Network 10 7 Devices 10 8 Advanced 11 Parental Control 11 1 Parental Control Settings 12 Exclusions 12 1 Websites 12 2 Files and Folders 12 3 Programs and Processes 12 4 Anti spam 13 Protection components 13 1 SpIDer Guard 13 1 1 Configuring SpIDer Guard 13 2 SpIDer Gate 13 2 1 Configuring SpIDer Gate 13 3 SpIDer Mail 13 3 1 Configuring SpIDer Mail 13 4 Anti spam 13 5 Dr Web Firewall 13 5 1 Training Firewall 13 5 2 Configuring Firewall 13 6 Dr Web for Outlook 13 6 1 Configuring Dr Web for Outlook 13 6 2 Threat Detection 13 6 3 Spam Check 44 44 45 46 46 49 50 52 53 54 55 56 59 60 62 62 62 63 63 65 65 65 69 69 72 73 76 78 78 79 87 87 88 91 y AN ax 13 6 4 Logging 13 6 5 Statistics 13 7 Preventive Protection Page Appendices Appendix A Command Line Parameters Scanner and Console Scanner Parameters Dr Web Update Command Line Parameters Return codes Appendix B Computer Threats and Neutralization Methods Classification of Computer Threats Actions Applied to Threats Appendix C Naming of Viruses 94 96 97 100 100 100 104 107 108 108 111 112 Ta J N ax 1 Introduction 1 Introduction Dr Web Security Space provides multilevel protection of RAM hard disks and removable devices against any ki
30. 36 Dr WEB Security Space Doctor Web 2015 All rights reserved This document is the property of Doctor Web No part of this document may be reproduced published or transmitted in any form or by any means for any purpose other than the purchaser s personal use without proper attribution TRADEMARKS Dr Web the Dr WEB logo SpIDer Mail SpIDer Guard CurelIt CureNet AV desk are trademarks and registered trademarks of Doctor Web in Russia and or other countries Other trademarks registered trademarks and company names used in this document are property of their respective owners DISCLAIMER In no event shall Doctor Web and its resellers or distributors be liable for errors or omissions or any loss of profit or any other damage caused or alleged to be caused directly or indirectly by this document the use of or inability to use information contained in this document Dr Web Security Space Version 10 0 User Manual 29 07 2015 Doctor Web Head Office 2 12A 3rd str Yamskogo polya Moscow Russia 125124 Web site www drweb com Phone 7 495 789 45 87 Refer to the official web site for regional and international office information Doctor Web Doctor Web develops and distributes Dr Web information security solutions which provide efficient protection from malicious software and spam Doctor Web customers can be found among home users from all over the world and in government enterprises small companies a
31. IR Several parameters can have modifiers that explicitly enable or disable options specified by these keys For example AC option is clearly disabled AC AC option is clearly enabled These modifiers can be useful if option was enabled or disabled by default or was set in configuration file earlier Keys with modifiers are listed below AC AFS AR BI DR HA LN LS MA NB NT OK QNA REP SCC SCN SLS SPN SPS SST TB TM TR WCL For FL parameter modifier directs to scan paths listed in the specified file and then delete this file For ARC ARL ARS ART ARX NI X PAL RPC W parameters 0 value means that there is no limit Example of using command line switches with Console Scanner lt path_to_file gt dwscancl AR AIN C AIC Q C scan all files on disk C excluding those in archives cure the infected files and move to quarantine those that cannot be cured To run Scanner the same way enter the dwscanner command name instead of dwscancl Ta 2 N ax Appendices 104 Dr Web Update Command Line Parameters Common options h help v verbosity arg d data dir arg log dir arg log file arg dwupdater log r repo dir arg t trace c command arg update z zone arg Show a short help message on how to use the program Log level Can be one of f
32. P watchman Dr Web Firewall Firewall does not log its operation in the standard mode When you enable detailed logging the component collects data on network packets pcap logs Dr Web Update List of updated Dr Web files and their download status date and time of updates and details on auxiliary script execution and Dr Web component restart Dr Web Information on Dr Web components changes in their settings component starts and stops Services preventive protection events connections to anti virus network Memory dump creation The Create memory dumps at scan errors option allows to save useful information on operation of several Dr Web components This helps Doctor Web technical support specialists analyze an occurred problem in detail and find a solution It is recommended to enable this option on request of Doctor Web technical support specialists or when errors of scanning or neutralizing occur Memory dump is saved to dmp file located in the PROGRAMFILES Common Files Doctor Web Scanning Engine folder Ta 2 i ax 10 Main Settings 58 Enabling detailed logging Upon logging detailed data on Dr Web operation the maximum amount of information is recorded This A will result in disabling of log file size limitations and will have an impact on system and Dr Web performance It is recommended to use this mode only when errors occur in component operation or by request of Doctor Web technical support 1 To enable deta
33. Scanner only FL lt path gt scan files listed in the specified file EM lt mask gt scan files matching the specified mask By default all files are scanned FR lt regexpr gt scan files matching the specified regular expression By default all files are scanned FULL perform a full scan of all hard drives and removable data carriers including boot sectors For Scanner only Ta J i ax Appendices EX lt mask gt exclude from scanning files that match the specified mask For Console Scanner only Hor show brief help For Console Scanner only HA use heuristic analysis to detect unknown threats Option is enabled by default KEY lt keyfile gt specify a license key file It is necessary to use this parameter if your key file is stored outside of the Dr Web installation folder where the scanner executables reside By default the drweb32 key or another suitable file from the C Program Files DrWeb folder is used LITE perform a basic scan of random access memory and boot sectors of all disks as well as run a check for rootkits For Scanner only LN resolve shell links Option is disabled by default LS use LocalSystem account rights Option is disabled by default MA check mail files Option is enabled by default MC lt limit gt set the maximum number of cure attempts to limit Number of attempts is unlimited by default
34. System To launch Scanner It is recommended to run Scanner under an account with administrative privileges Otherwise all folders and files including system folders that are not accessible to unprivileged user including system folder are not scanned 1 To launch Scanner do one of the following e Click the Scanner icon on the desktop e Click the SpIDer Agent icon E on the notification area and select Scanner e Click Start select the Dr Web item and then select Dr Web Scanner e Enter the corresponding command in the Windows command line for details refer to Scanning in Command Line Mode To launch Scanner with default settings to scan a certain file or folder select Check with Dr Web 33 8 Dr Web Scanner 34 Express Scanning of critical system objects Performing an express scan once a week is recommended Complete Scanning of all files on logical drives and removable media Custom Specify objects for scanning Dr Web Scanner is checking computer L l 4 Starting time 15 29 45 Scanned objects 69 Time remaining Threats detected 0 Object Device HarddiskVolume2 Windows System32 Drivers Npfs SY S _ Y Show additional information 3 There are tree scanning modes Express scan Full scan and Custom scan In Express scan mode Scanner checks the following e Boot sectors of all disks Random access memory Boot disk root folder Windows system fold
35. act you Self Protection I want to connect to services recommended I will decide later Anti Virus Network Devices Advanced Privacy statement by Doctor Web Cloud Services Dr Web Cloud Checker provides most recent information on threats which is updated on Doctor Web servers in real time mode and used for anti virus protection Depending on update settings information on threats used by anti virus components may become out of date Cloud services can reliably prevent users from viewing unwanted websites and protect your system from infected files Software Quality Improvement Program If you participate in the software quality improvement program impersonal data about Dr Web operation on your computer will be periodically sent to the Doctor Web servers for example information on created rule sets for Dr Web Firewall Received information is not used to identify or contact you Click the Privacy statement by Doctor Web link to look through a privacy statement on the Doctor Web official website 53 10 6 Anti virus Network 10 Main Settings 54 On this page you can enable remote control of your anti virus from other local network computers by Anti virus Network If your computer is connected to an anti virus network you can create local update mirrors and control anti virus protection state or your computer remotely view statistics enable or disable Dr Web components and adjust their settings For r
36. actions with objects require scanning on the fly with SpIDer Guard Optimal This scan mode is used by default recommended In this mode SpIDer Guard scans objects only when one of the following actions is traced e For objects on hard drives an attempt to execute a file create a new file or add a record to an existing file or boot sector e For objects on removable devices an attempt to access file or boot sectors in any way write read execute Paranoid In this mode SpIDer Guard scans files and boot sectors on hard or network drives and portable data storages at any attempt to access them create write read execute When running in the Optimal mode SpIDer Guard does not terminate execution of an EICAR test file A and the file is not processed as malicious since it does not pose any actual threat to your system However if you copy or create such a file in your system it will be detected by SpIDer Guard and moved to Quarantine by default The Optimal mode is recommended for use after a thorough scan of all hard drives by Dr Web Scanner With this mode activated SpIDer Guard prevents penetration of new viruses and other malicious objects via removable devices into your computer while preserving performance by omitting knowingly clean objects from repeated scans The Paranoid mode ensures maximum protection but considerably reduces computer performance In any mode objects on removable media and network drives are s
37. add addresses 1 Click Add 2 In the Edit list window enter the address see white and black lists filling methods 3 Click OK in the Edit list window To change addresses 1 Select the address you want to change and click Edit 2 Change the address 3 Click OK in the Edit list window To delete addresses 1 Select the address you want to delete from the list 2 Click Delete In the Black and White lists window click OK to save changes Ta J 1 ax 13 Protection components White List If the sender s address is on the white list the message is not scanned for spam But if domain name of receiver and sender addresses are matched and this domain name is specified in the white list using a special asterisk character this message will be checked for spam Details e To add a certain sender enter the full email address for example friend mail com This ensures delivery of all messages from this sender Each list item can contain only one address or address mask e To add a group of sender addresses enter the mask that determines their names The mask defines a template for an object definition It may contain regular characters from email addresses and a special asterisk character which replaces any including an empty one sequence of characters For example the following addresses are available e mailbox domain com e box domain com e mailbox dom e box dom The asterisk can be
38. ails on Dr Web Scanner operation are logged which may result in considerable log growth It is recommended to use this mode only when errors occur in Dr Web Scanner operation or by request of your Doctor Web technical support Size of the log file in the Standard mode is restricted to 10 MB In the Debug mode the log file size is not limited After scanning if the log file size exceeds the limit the content is reduced to e Specified size if the current session information does not exceed the limit e Size of the current session if the session information exceeds the limit thus the information is stored until the next scan When scanning starts the log file is reduced to the size specified in the settings Restore Defaults Page On the Restore defaults page you can restore Scanner settings to their default values recommended by Doctor Web For that purpose click Restore defaults vy BO A Main Actions Exclusions Log Restore defaults Restoring defaults will delete all Dr Web Scanner settings specified by the user Restore defaults 8 4 Scanning in Command Line Mode You can run Scanner in the command line mode then you can specify settings of the current scanning session and list objects for scanning as additional parameters Automatic activation of the Scanner according to schedule is performed in this mode Ta J i ash 8 Dr Web Scanner To run scanning from command line For that purpos
39. all messages from addresses within the spam com domain will be regarded as spam automatically To regard as spam messages sent from an email address with a certain user name from any domain specify an asterisk character instead of the domain name in the address For example if you enter someone all messages from all senders with the someone mailbox name will be regarded as spam automatically Addresses from the recipient domain are not processed For example if the recipient mailbox your mailbox is in the mail com domain then messages from mail com domain will not be processed with the anti spam filter 93 Ta J i ax 13 Protection components 94 13 6 4 Logging Dr Web for Outlook registers errors and application events in the following logs e Windows Event Log e Debug Text Log Event Log The following information is registered in the Windows Event Log e Program starts and stops e Key file parameters license validation license expiration date information is logged on program startup while the program is running and when the key file is changed Parameters of program modules scanner engine virus databases information is logged on program startup and module update License errors the key file is absent permissions for program module usage is absent in the key file the license is blocked the key file is corrupted information is logged on program startup and while the program is running Info
40. by the majority of anti viruses as if it were a virus On detection of this virus Dr Web report the following EICAR Test File Not a Virus Other anti virus tools alert users in a similar way The test com program is a 68 byte COM file that prints the following line on the console when executed ITCAR STANDARD ANTIVIRUS TEST FILE The test com file contains the following character string only X50 PS AP 4 P2X54 P 7CC 7 SETCAR STANDARD ANTIVIRUS TEST FILE SH H To make your own test file with the virus create a new file with this line and save it with as test com When you attempt to execute an EICAR file while SpIDer Guard is running in the optimal mode the A operation is not terminated and the file is not processed as malicious since it does not pose any actual threat to your system However if you copy or create such a file in your system it will be detected by SpIDer Guard and moved to Quarantine by default Ta 2 ww ax 6 Tools 25 6 Tools 6 1 License Manager This window displays information on Dr Web licenses To open this window click the SpIDer Agent icon amp in the notification area and select License In the upper part of the window you can find information about the license you are using Tools Current license 115196679 License Manager License type Serial number Owner
41. canned only if the corresponding check boxes in the Additional tasks group are selected Operating system may register some removable devices as hard drives e g portable USB hard drives Scan such devices with Dr Web Scanner when you connect them to the computer By default files within archives and mailboxes are not checked This does not affect security of your computer when it is constantly protected by SpIDer Guard only delays the moment of detection If a file within an archive or email attachment is infected the malicious object will be detected and neutralized by SpIDer Guard immediately when you try to extract the archived files or download the attachment Additional Tasks The settings of this group allow to specify parameters for scanning objects on the fly and are always applied regardless of the selected SpIDer Guard operation mode In this group you can configure SpIDer Guard parameters to check the following objects Ta J 1 ax 13 Protection components 68 e Executables of running processes regardless of their location this option is enabled by default e Installation files e Files on network drives e Files and boot sectors on removable devices this option is enabled by default By default SpIDer Guard blocks autoplay option for portable data storages such as CD DVD flash memory and so on This option helps to protect you computer from viruses transmitted via removable media If any problem occur
42. cted copies Data Loss Prevention On a Anti Virus Network Choose files and folders for protection Quarantine Manager Copy files to C DrWeb Archive Support Protected copies were created at 23 10 2014 13 57 Create copy To cancel unwanted changes you can restore your files from protected copies If your files were corrupted you can restore their copies created by the certain date To do that click the Restore button in the main window In the window displayed select the required date and all copies that were available for the date will be restored to the specified folder To start creation of protected copies manually click the Create copy button in the main window In 26 Ta AN ax 6 Tools the window displayed specify the description for the new copy To create protected copies you need to have minimum 5 Gb free disk space on the disk that is selected for storing protected copies 6 3 Anti virus Network This component allows to manage version 10 0 of Dr Web Anti virus for Windows Dr Web Anti virus for Windows Servers or Dr Web Security Space on other computers of your network To access Dr Web remote control click the SpIDer Agent amp select Tools and then select Anti virus Network Tools Computers found You can review summary information about Dr Web product on selected License Manager computer If you have remote access to a computer you can manage settings and enable
43. cure messages infected with a known and supposedly curable virus and moves incurable and suspicious messages as well as adware and dialers to Quarantine at the same time ignoring all other minor threats Other messages are transmitted unchanged by SpIDer Mail skipped The SpIDer Mail reactions are similar to those of Dr Web Scanner You can select one of the following actions applied by SpIDer Mail to detected threats Cure Instructs to try to restore the original state of the message before infection If the message is incurable or the attempt of curing fails the action set for incurable message is applied Ta 1 aX 13 Protection components 74 Available for Infected messages only except Trojan programs that are deleted on detection This is action is not applicable to files within archives Delete Instructs to delete the message The message is not sent to recipient the mail client receives a notification about this Move to Quarantine Instructs to move the message to the special Quarantine folder The message is not sent to the recipient the mail client receives a notification about this Ignore Instructs to pass the message to the mail client as usual i e without performing any action If an email contains a malicious object any reaction except Ignore results in failure to send the message to a mail server or recipient To increase security above the default level you may select the Move to quarantine acti
44. d the entered address to the list click 3 To add other addresses repeat steps 1 to 2 To remove an address from the list select the corresponding item and click 64 Ta J 1 ax 13 Protection components 13 Protection components 13 1 SpIDer Guard SpIDer Guard is an on access anti virus scanner that constantly resides in memory while scanning files and RAM on the fly and instantly detects any malicious activity With the default settings the component performs on access scans of files that are being created or changed on the hard drives and all files that are opened on removable media Moreover SpIDer Guard constantly monitors running processes for virus like activity and if such is detected blocks malicious processes and reports on the event On detection of an infected object SpIDer Guard processes it according to the specified settings Files within archives and mailboxes are not checked If a file within an archive or email attachment is infected the malicious object will be detected and neutralized by SpIDer Guard immediately when you try to extract archived files or download the attachment To prevent spread of viruses and other malicious objects with email use SpIDer Mail On detection of an infected object SpIDer Guard applies actions to them according the specified settings You can change settings to configure automatic reaction to different virus events You can also connect to Doctor Web cloud se
45. de Limits on use of computer resources This option limits the use of computer resources by Dr Web Scanner The default value is 50 Use sound alerts Automatically apply actions to threats and Turn off computer after scanning parameters can be also set in the Dr Web Scanner Main window or Custom Scan Settings window To set the parameters click Actions Page icon on the toolbar To set reaction to threat detection 1 Select the Actions page in the settings window Main Actions Exclusions Log Restore defaults E Infected Cure recommended ba Incurable Move to quarantine recommended ma Suspicious Move to quarantine recommended me f Adware Move to quarantine recommended x Dialers Move to quarantine recommended mi Jokes Move to quarantine recommended nA Riskware Move to quarantine recommended Hacktools Move to quarantine recommended MA Containers Move to quarantine recommended A E _ Help 2 Inthe Infected drop down list select an action to take upon detection of an infected object A The Cure action is the best in most cases 3 In the Incurable drop down list select an action to take upon detection of an incurable object The range of actions is the same as for infected objects but the Cure action is not available A Th
46. de Select this check box to hide notifications when an application is running in full screen mode on your computer e g a game or a movie Clear this check box to display notifications regardless of the mode Select this check box to display notifications from Firewall on a separate desktop when an application is running in full screen mode on your computer a game or a movie Clear to display notifications on the same desktop where an application is running in the full screen mode 4 If you selected one or more email notifications configure sending emails from your computer 5 After editing click OK to save the changes or Cancel to cancel them Threat notifications Major notifications Critical notifications Minor notifications Select to be notified on detected threats Clear if you do not want to be notified By default these notifications are enabled Select to be notified on the following major issues e Expiration of the time limit set for working on the computer e Attempts to change system date e New product version release e Outdated virus databases Clear this check box if you do not want to be notified on the issues listed above By default these notifications are enabled Select to be notified on the following critical issues e Expiration of your license period e Failures to make a protected copy e Detection of connections waiting for Firewall to reply Clear this check box if you do not want to be notified
47. diskettes and partitions or master boot records of fixed disks Such viruses are called boot viruses They take very little memory and remain ready to continue performing their tasks until a system roll out restart or shutdown occurs Macroviruses are viruses which infect documents used by the Microsoft Office and some other applications which allow macro commands usually written in Visual Basic Macro commands are a type of implemented programs macros written in a fully functional programming language For instance in Microsoft Word macros can automatically initiate upon opening closing saving etc a document A virus which has the ability to activate and perform the tasks assigned by the virus writer only when the computer reaches a certain state e g a certain date and time is called a memory resident virus Most viruses have some kind of protection against detection Protection methods are being constantly improved and ways to overcome them are developed Encrypted viruses for instance cipher their code upon every infection to hamper their detection in a file boot sector or memory All copies of such viruses contain only a small common code fragment the decryption procedure which can be used as a virus signature Polymorphic viruses also encrypt there code but besides that they generate a special decryption procedure which is different in every copy of the virus This means that such viruses do not have byte signatures 108
48. during installation with autorun option it is recommended to clear Block autoruns from removable media check box Ta N ax 13 Protection components 13 2 SpIDer Gate SpIDer Gate is an HTTP monitor By default the component automatically checks incoming HTTP traffic and blocks all malware objects HTTP is used by web browsers download managers and other applications which exchange data with web servers that is which work with the Internet By default SpIDer Gate blocks all incoming malicious objects You can configure SpIDer Gate to completely disable monitoring of incoming or outgoing traffic compose a list of applications whose HTTP traffic should always be checked or exclude certain applications from being monitored By default SpIDer Gate blocks all incoming malicious objects URL filtering of malicious and unreliable websites is also enabled by default You can also connect to Doctor Web cloud services which allow anti virus components to use the latest information on threats This information is stored and updated on Doctor Web servers in real time mode SpIDer Gate resides in the main memory of the computer and automatically launches upon Windows startup 13 2 1 Configuring SpIDer Gate To access the SpIDer Gate settings you are prompted to enter the password if you enabled Protect Dr Web settings by password option on the Settings window The default settings are optimal for most uses Do not change
49. e rules for known applications are created automatically U For other applications you have control over Firewall reaction that is you can allow or block unknown connections as well as create new rules When a user application or operating system attempts to connect to a network Firewall checks whether a filtering rule set for the application is created If no filtering rule is set for the application you are prompted to select a temporary solution or create a rule to be applied each time this type of connection is detected This mode is used by default Interactive learning mode In this mode you have total control over Firewall reaction on unknown connection detection thus training the program while working on computer Ta J 1 aX 13 Protection components When a user application or operating system attempts to connect to a network Firewall checks whether a filtering rule set for the application is created If no filtering rule is set for the application you are prompted to select a temporary solution or create a rule to be applied each time this type of connection is detected Block unknown connections In this mode Firewall automatically blocks all unknown connections to network resources including the Internet When a user application or operating system attempts to connect to a network Firewall checks whether a filtering rule set for the application is created If there are no filtering rules Firewall blocks
50. e use the following command lt path_to_program gt dwscanner lt switches gt lt objects gt where e lt objects gt is a placeholder for the list of objects to be scanned e lt switches gt is a placeholder for command line parameters that configure Scanner operation If no switches are defined scanning is performed with the settings specified earlier or with the default settings if you have not changed them The list of objects for scanning can be empty or contain several elements separated by spaces The most commonly used examples of specifying the objects for scanning are given below e FAST perform an express scan of the system e FULL perform a full scan of all hard drives and removable data carriers including boot sectors e LITE perform a basic scan of random access memory and boot sectors of all disks as well as run a check for rootkits 43 A AN T v A A 8 Dr Web Scanner 44 8 5 Console Scanner Dr Web also includes Console Scanner which allows you to run scanning from the command line and provides advanced settings A Console Scanner moves suspicious files to Quarantine To run Console Scanner The command syntax to launch Console Scanner is as follows lt path_to_program gt dwscancl lt switches gt lt objects gt where e lt objects gt is a placeholder for the list of objects to be scanned e lt switches gt is a placeholder for command line param
51. e Internet and computer for certain Windows accounts By restricting access to the local file system you can maintain integrity of important files protect them from viruses and secure confidentiality of stored data It is possible to restrict access to separate files or folders on local drives and external data carriers You can also completely restrict copying data to any kinds of external data carriers To prevent unauthorized access to data or its theft you can restrict access to such devices as USB ports hard drives disk drives and so on By controlling access to web resources you can restrict a user from viewing undesirable websites for example pages on violence gambling adult content etc or allow access to certain websites only that are specified in the Parental Control settings You can also connect to Doctor Web cloud services which allow anti virus components to use the latest information on threats This information is stored and updated on Doctor Web servers in real time mode 59 Ta yan A A 11 Parental Control 11 1 Parental Control Settings The default settings are optimal for most uses Do not change them unnecessarily To configure Parental Control settings 1 Click the SpIDer Agent icon amp in the notification area select Parental Control and then select Settings 2 Configure the settings as necessary 3 To get information on options available on the page click Help To manage Pa
52. e Move to quarantine action is the best in most cases Ta 2 ww ys 8 Dr Web Scanner 4 In the Suspicious drop down list select an action to take upon detection of a suspicious object fully similar to the previous paragraph 5 Similar actions should be specified for detection of objects containing Adware Dialers Jokes Riskware and Hacktools 6 The same way the automatic actions of the program upon detection of viruses or suspicious codes in file archives installation packages and mailboxes applied to these objects as a whole are set up 7 To cure some infected files it is necessary to reboot Windows You can select one of the following e Prompt restart e Restart computer automatically It can lead to loss of unsaved data The best action for curable threats e g files infected with known viruses is curing since it allows to restore the infected file completely It is recommended to move other threats to quarantine in order to prevent loss of potentially valuable data You can select one of the following actions Cure Move to Quarantine Delete Ignore Instructs to restore the original state of an object before infection If the object is incurable or an attempt of curing fails the action set for incurable viruses is applied This action is available only for objects infected with a known virus that can be cured except for Trojan programs and ffiles within complex objects archives email attachment
53. e SpIDer Agent icon E in the Windows notification area To access the protection components and settings and to disable components you need to have administrative privileges The SpIDer Agent menu allows to perform the main management and setting functions of Dr Web My Dr Web Opens your personal webpage on the Doctor Web official website This page provides you with information on your license including usage period and serial number allows to renew the license contact technical support and so on License Starts the License Manager Tools Opens a submenu providing access to e Data Loss Prevention e Anti virus Network e Quarantine Manager e Support section Protection components Quick access to the protection components list where you can enable or disable each of the components Updater Information about actuality of the components or virus databases Launches the update Scanner Quick access to launching different kinds of scanning O Working mode Allows to switch between user mode and administrator mode By default Dr Web starts in restricted user mode which does not provide access to Settings and settings of Protection components To switch to another mode click the lock If UAC is enabled operating system will prompt a request for administrative privileges Besides you also need to enter the password to change the mode if you set Protect Dr Web settings by password option on the Settings window
54. e SpIDer Gate to check encrypted data transferred over HTTPS protocol and configure SpIDer Mail to check messages sent over POP3S SMTPS or IMAPS In order for Dr Web to scan such encrypted traffic and maintain transparent integration with some browsers and mail clients that do not refer to the Windows system certificate storage it may be necessary to import Doctor Web SSL certificate into the application certificate storages To save the certificate from the system storage for future use in third party applications click Export and select a convenient folder 51 Ta yan A A 10 Main Settings 10 4 Self protection On this page you can configure protection of Dr Web itself from unauthorized modification e g by anti antivirus programs or accidental damage Main Self protection Enable self protection recommended Notificati otifications On a Update Block user activity emulation Network On a Self Protection Dr Web Cloud Date and time Anti Virus Network Block changing of system date and time When Parental Control is enabled recommended Devices Block always Advanced The Enable Self protection option allows to protect Dr Web files and processes from damage or deletion It is not recommended to disable Self protection 1 If any problems occur during operation of defragmentation programs disable Self protection temporary To rollback to a system restore point disable Self protect
55. e selection of objects to be neutralized by using check boxes next to object names or threat categories from the drop down menu in the table header To select an action 1 Where necessary select a custom action from the drop down list in the Action field By default Dr Web Scanner selects a recommended action 2 Click Neutralize Dr Web Scanner applies actions to the selected threats There are the following limitations e For suspicious objects curing is impossible e For objects which are not files boot sectors moving and deletion is impossible e For files inside archives installation packages or attachments no actions are possible The detailed report on program operation is stored in the dwscanner log file that is located in USERPROFILE Doctor Web folder Object This table column contains the name of an infected or suspicious object it is a file name if a file is infected or Boot sector if a boot sector is infected or Master Boot Record if an MBR of the hard drive is infected 8 Dr Web Scanner 37 Xen EANA K Threat Action Path In this column names of viruses or virus modifications are listed as per the internal classification of the Doctor Web package a modification of a known virus is a code resulting from such alteration of a known virus which can still be detected but cannot be treated with the curing algorithms applied to the initial virus For suspicious objects an indication that the object is pos
56. ecified will be excluded from scanning this option is appropriate for temporary files swap files etc You can also add archives email files and installation packages to scanning Log Page On this page you can specify the logging mode Dr Web Scanner operation is logged to the dwscanner log file located in the USERPROFILE Doctor Web folder It is recommended to periodically analyze the log file x B On o Main Actions Exclusions Log Restore defaults Specify logging level Maximum 3 Standard General information about Dr Web Scanner Starts of Dr Web Scanner and total checking time Detected errors and threats Minimum Most parameters set by default should be left unchanged However you can change the details of logging by default information on infected or suspicious objects is always logged information on Ta 1 ax 8 Dr Web Scanner 42 scanned packed files and archives and on successful scanning of other files is omitted You can specify one of the following verbosity levels for logging e Standard in this mode main events are logged such as time of updates time of Dr Web Scanner starts and stops information on detected threats and also names of packers and content of scanned archives is logged If required you can add such objects to the list of exclusions which can reduce system load This logging mode is optimal for most uses e Debug in this mode all det
57. ectors including master boot record MBR of the hard drive TM check processes in memory including Windows system control area TR check system restore points W lt sec gt maximum time to scan sec By default the time is unlimited WCL drwebwcl compatible output For Console Scanner only X S R set power state ShutDown Reboot Suspend Hibernate with reason R for shutdown reboot A AN T v A 4 Yy Appendices 103 Action for different objects C cure Q move to quarantine D delete T ignore R inform R is available for Console Scanner only R is set by default for all objects in Console Scanner e AAD lt action gt action for adware possible DQIR e AAR lt action gt action for infected archives possible DQIR e ACN lt action gt action for infected installation packages possible DQIR e ADL lt action gt action for dialers possible DQIR e AHT lt action gt action for hacktools possible DQIR e AIC lt action gt action for incurable files possible DQR e AIN lt action gt action for infected files possible CDQR e AJK lt action gt action for jokes possible DQIR e AML lt action gt action for infected email files possible QIR e ARW lt action gt action for riskware possible DQIR e ASU lt action gt action for suspicious files possible DQ
58. ed when a packet is sent into the network from your computer e e the rule is applied regardless of packet transfer direction The logging mode for the rule This parameter defines which information is stored in the log e Headers only log the packet header only e Entire packet log the whole packet e Disabled no information is logged The rule description 1 If you selected to create or edit an existing rule set on the Packet filtering settings page in the open window specify the name for the rule set 2 Use the following options to create filtering rules e To add a new rule click Create The new rule is added to the beginning of the list e To modify a rule select it and click Edit Ta 1 aX 13 Protection components 86 e To copy the selected rule to the list click Copy The copy is added after the selected rule e To remove the selected rule click Delete 3 If you selected to create or edit a rule configure the rule settings in the open window 4 Use the arrows next to the list to change the order of rules The rules are applied according to their order in the set 5 When you finish adjusting the settings click OK to save changes or Cancel to reject them Packets with no rules in a rule set are blocked automatically except packets allowed by Application Filter rules Packet Filter Rule Sets To add or edit a rule 1 In the packet filter rule set creation or modification window c
59. emote access to Dr Web settings on your computer the password is required You may use the password that is automatically generated when the option is enabled or set a new one Main Notifications Update Network Self Protection Dr Web Cloud Anti Virus Network Devices Advanced Anti virus Network You can enable remote control of Dr Web product on your computer from other Dr Web products installed on the local area network Users who remotely access your anti virus will be able to view statistics enable or disable components and modify the settings of certain modules Enable remote control Off Cm User Manual Ta AN ax 10 Main Settings 10 7 Devices A Access control configuration are applied to all Windows accounts Devices To block access to data on the removable media USB flash floppy CD DVD ZIP drives etc enable the appropriate option To block sending jobs to printers enable the Block sending jobs to printers flag This option is disabled by default You can also block data transfer over network LAN and the Internet Main Devices Restrict access to the removable media Notifications ss Block sending jobs to printers Update Block data transfer over network LAN and the Internet Network Self Protection Restrictions Dr Web Cloud Block the usage of specified devices for all users On a Anti Virus Network White list 0 Devices Device classes
60. er User documents folder My Documents User Manual AT y 8 Dr Web Scanner 35 A e Temporary files e System restore points e Presence of rootkits if the process is run with administrative privileges A Scanner does not check archives and email files in Express scan mode If full scan mode is selected random access memory and all hard drives including boot sectors of all disks are scanned Scanner also runs a check on rootkits Custom scan mode allows you to select any files and folders for scanning Custom scan m Scanning objects _ e Run scanning process with E Boot sectors of all disks administrative rights a mm Random access memory E E Boot disk root folder E amp Windows system folder m mm User documents folder My Documents T amp Temporary files m System restore points E Rootkits Click to select files and folders Start scanning 4 If you launch a custom scan you can select objects from the list to be scanned any files and folders and such objects as random access memory boot sectors and so on To start scanning selected objects click Start scanning In full scan or express scan modes objects cannot be selected manually 5 When scanning starts the Pause and Stop buttons become available During scanning you can do the following e To pause scanning click Pause To resume scanning after pause click Resume e To stop scanning c
61. er Settings To configure spam filtering settings do any of the following actions e To run spam checks select the Check for spam check box e You can add special text to the spam message header by setting the Add prefix to message header check box The added prefix text is specified to the right of the flag The default prefix is e The checked messages can be marked as read in the message options To mark messages as read on spam check select the Mark message as read check box By default this check box is selected e You can also configure black and white lists for message filtering Ta J 1 ax 13 Protection components 92 If spam filter defines certain messages incorrectly you are advised to forward such messages to special email addresses for analysis and improvement of filtering methods e Messages which are wrongly regarded as spam should be forwarded to vrnonspam drweb com e Unblocked spam messages should be forwarded to vrspam drweb com Forward messages as attachments do not include them in the message body Using Black and White Lists Black and white lists are used for messages filtration To review and to edit the black and white lists in the spam filter window click Black list or White list respectively Black and white lists x White list Black list Messages from e mails included into the white list are passed through without check for spam To
62. eters that configure Console Scanner operation The list of objects for scanning can be empty or contain several elements separated by spaces All switches start with the forward slash and are separated by spaces All Console Scanner parameters are listed in Appendix A After the operation is complete Console Scanner returns one of the following codes 0 scanning completed successfully infected objects were not found 1 scanning completed successfully infected objects were detected 10 invalid keys are specified 11 key file is not found or does not support Console Scanner 12 Scanning Engine did not start 255 scanning was aborted by user request 8 6 Automatic Launch of Scanning During Dr Web installation an anti virus scan task is automatically created in the Task Scheduler the task is disabled by default To view the parameters of the task open Control Panel Administrative Tools Task Scheduler In the task list select the scan task You can enable the task adjust trigger time and set required parameters On the General page you can review general information and security options on a certain task On the Triggers and Conditions pages various conditions for task launching are specified To review event log select the History tab You can also create your own anti virus scan tasks For details on the system scheduler operation please refer to the Help system and Windows documentation I
63. eters window opens 3 Installing the program 16 On the first tab you can specify the components you want to install lt Dr WEB Installation parameters Components Installation path Updater Automatic Updating Utility Scanner Scans computer for viruses on demand SpIDer Mail Scans e mails for viruses v Anti spam Protects e mails from spam SplDer Guard Protects computer from viruses in real time Plua in for Microsoft Outlook Doctor Web 1992 2014 English Advanced options 0 2 MB 17 R MR 8 On this tab you can change the installation path 9 If you specified a valid key file or selected Receive license during installation at step 5 the last page of the window allows you to select Update during installation check box to download updates to virus databases and other program components The window also prompts you to create shortcuts to start Dr Web When you finish adjusting the installation parameters click OK 10 If you selected Receive license during installation at step 5 the procedure of receiving the key file from the Internet via the Registration Wizard starts 11 If you specified a key file or received it during the installation and selected Update during installation check box at step 9 the Wizard updates virus databases and other Dr Web components Updating starts automatically and does not require any additional actions 12
64. f installed components include Firewall Task Scheduler will be blocked by Firewall after Dr Web installation and the first system restart Scheduled tasks will operate only after second restart when a new rule is already created Ta AN ax 9 Settings 9 Settings 45 A Managing settings is available only when having administrative privileges Password protection To restrict access to the Dr Web setting on your computer enable the Protect Dr Web settings with a password option In the window displayed specify the password that will be required to configuring Dr Web confirm it and click OK A If you forgot your password for the product settings contact technical support Settings ETN Parental Control Exclusions Protection Components Manage settings Password Protect Dr Web settings with a password Off Cm Manage settings You can save product settings by exporting them to hard disk as a file import settings or restore default settings Change v To restore default settings select Reset settings in the drop down list If you want to use settings of Dr Web anti virus that you already configured on another computer select Import in the drop down list If you want to use your settings on other computers select Export in the drop down list Then apply them on the same page of another anti virus Ta AN ax 10 Main Settings 46 10 Main Settings To access the ma
65. f objects which moved to Quarantine Deleted number of objects removed from the system Skipped number of objects skipped without changes Spam messages number of objects detected as spam By default statistics is saved to the drwebforoutlook stat file located in the USERPROFILE DoctorWeb folder A The drwebforoutlook stat statistics file is individual for each system user Ta ww ax 13 Protection components 97 13 7 Preventive Protection Page On this page you can configure Dr Web reaction to such actions of other programs that can compromise security of your computer You can also protect your important data from unwanted changes Protection Level of suspicious activity blocking Components Optimal recommended SpIDer Guard Protected object Spite ae Integrity of running applications Selber ct Integrity of users files Anti spam HOSTS file Firewall 1 Low level disk access Preventive Protection Divemibaiig Image File Execution Options Windows Multimedia Drivers Winlogon parameters Winlogon notifiers Preventive Protection Level In the Optimal mode set by default Dr Web disables automatic changes to system objects modification of which explicitly signifies a malicious attempt to harm the operating system It also blocks low level access to disk and protects the HOSTS file from modification If there is a high risk of you computer getting infected
66. from scanning all files stored in C folder The files stored within the subfolders will be scanned e C folder excludes all files located in C folder and its subfolders e C folder txt excludes all txt files stored in C folder The txt files stored within the subfolders will be scanned e C folder txt excludes all txt files stored in the first level subfolders of C folder e C folder txt excludes all txt files stored in subfolders of any level within C folder The files stored in C folder itself including txt files will be still scanned 12 3 Programs and Processes You can specify a list of processes to be excluded from scanning by SpIDer Guard SpIDer Gate and SpIDer Mail The default list is empty Add particular files and folders to exclusions or use masks to disable scanning of a certain group of files To configure list of exclusions 1 To add a program or a process to exclusion list click In the open window click Browse and select it in the standard dialog window 2 In the configuration window specify the components that must not scan this file 3 Click OK The process or program will appear in the list 4 If necessary repeat the procedure to add other processes 5 To edit existing exclusion click 6 To remove a file from the list select the corresponding item and click 12 4 Anti spam In this window you can configure lists of sende
67. g background rootkit scanning files and folders specified on Excluded files page of SpIDer Guard are excluded from scanning To enable background scanning set the Scan computer for rootkits recommended check box Disabling of SpIDer Guard does not affect background scanning If the check box is set background scanning is performed regardless of whether SpIDer Guard is enabled or disabled Actions On this page you can configure reactions of SpIDer Guard to detection of infected or suspicious files and malware For different types of compromised objects actions are assigned separately from the respective drop down lists e Objects infected with a known and supposedly curable virus e Supposedly infected suspicious objects e Objects that pose potential threat riskware Reaction of SpIDer Guard to detection of various malicious software is also set separately Set of actions available for selection depend on the type of the virus event By default SpIDer Guard attempts to cure the infected and supposedly curable files moves other most dangerous objects to Quarantine and ignores minor threats such as jokes hacktools and riskware The SpIDer Guard reactions are similar to those of Dr Web Scanner You can select one of the following actions for detected virus threats Cure move to Instructs to restore the original state of an object before infection If the object is quarantine if not incurable or the attempt of curing fai
68. gram in a transparent mode as if they were received immediately from the server Similar procedure is applied to outgoing messages before they are sent to servers By default SpIDer Mail reacts to detection of infected incoming messages as well as messages that were not scanned for example due to complicated structure as follows for details on how to modify the reaction refer to Configuring SpIDer Mail e Malicious code is removed from infected messages then messages are delivered as usual This action is called curing the message e Messages with suspicious objects are moved to Quarantine as separate files the mail client receives a notification about this This action is called moving the message All deleted or moved messages are also deleted from the POP3 or IMAP4 mail server e Messages that were not scanned and safe messages are passed on to the mail client Infected or suspicious outgoing messages are not sent to the server a user is notified that the message will not be sent usually the mail program will save such a message Dr Web Scanner can also detect viruses in mailboxes of several formats but SpIDer Mail has several advantages e Not all formats of popular mailboxes are supported by Scanner When using SpIDer Mail the infected messages are even not delivered to mailboxes e Scanner does not check the mailboxes at the moment of the mail receipt but either on user demand or according to schedule Thus whe
69. h could be used to assign it some specific name e Silly this prefix was used to name simple featureless viruses the with different modifiers in the past Suffixes Suffixes are used to name some specific virus objects e generator an object which is not a virus but a virus generator 114 Ta J 1 ax Appendices e based a virus which is developed with the help of the specified generator or a modified virus In both cases the names of this type are generic and can define hundreds and sometimes even thousands of viruses e dropper an object which is not a virus but an installer of the given virus 115 Doctor Web 2015
70. hecks all files for viruses using both the virus database and the heuristic analyzer a method based on the general algorithms of virus developing allowing to detect the viruses unknown to the program with a high probability Executable files compressed with special packers are unpacked when scanned Files in archives of all commonly used types ACE ALZIP AR ARJ BGA 7 ZIP BZIP2 CAB GZIP DZ HA HKI LHA RAR TAR ZIP etc in containers 1C CHM MSI RTF ISO CPIO DEB RPM etc and in mailboxes of mail programs the format of mail messages should conform to RFC822 are also checked On detection of a malicious object Dr Web Scanner only informs you about them Information on all infected or suspicious objects displays in the table where you can manually select a necessary action You can apply default actions to all detected threats or select the required reaction to a certain object The default settings are optimal for most cases However if necessary you can modify the suggested actions in the Dr Web Scanner settings window Please note that you can specify a custom action for each detected threat after the scan is complete but common reaction for a particular threat type should be configured beforehand You can also connect to Doctor Web cloud services which allow anti virus components to use the latest information on threats This information is stored and updated on Doctor Web servers in real time mode 8 1 Scanning Your
71. ial Quarantine folder Skip skip the object without performing any action or displaying a notification Ta J 1 aX 13 Protection components 91 13 6 3 Spam Check Dr Web for Outlook checks emails for spam by means of Dr Web Anti spam and filters the messages according to the user defined settings To configure spam check in the Tools gt Options Dr Web Anti virus page for Microsoft Outlook 2010 in the Files Options Add ins section select Dr Web for Outlook and click the Add in Options button click Spam filter The Spam filter window opens The Spam filter window is available only for users with administrative privileges For Windows Vista and later operating systems after clicking Spam filter e If UAC is enabled administrator is requested to confirm program actions user without administrative privileges is requested to enter accounting data of system administrator e If UAC is disabled administrator can change program settings user does not have the permission change program settings Configuring Spam Filter Anti spam filter Spam filtering parameters l V Check for spam Z Add prefix to message header 5 PAM V Mark message as read Black and white lists PD Messages from e mails included into the white list are passed through without GN check for spam White list Messages from e mails included into the black list are always considered as spam Black list Spam Filt
72. ied if you want to use the settings specified for the selected operation mode of Firewall e User defined enables you to create a set of rules that allow or block different connections 2 When you select the User defined mode a table with details on the application rule set displays below Enabled Status of the rule Action The action for Dr Web Firewall to perform when an attempt to connect to the Internet is detected e Block packets block the connection e Allow packets allow the connection Rule name The rule name Direction The direction of the connection e Inbound the rule is applied when someone from the network attempts to connect to an application on your computer e Outbound the rule is applied when an application on your computer attempts to connect to the network e Any apply the rule regardless of packet transfer direction Description User description of the rule 3 If necessary edit the predefined rule set or create a new one e To add a new rule click Create The rule will be added to the end of the list e To modify a rule select it and click Edit e To copy the selected rule to the list click Copy The copy is added after the selected rule e To remove the selected rule click Delete 4 If you selected to create a new rule set or edit the existing one adjust the settings in the open window Ta yan A A 13 Protection components 83 Application filte
73. ified only they will be updated Components that should be updated to the specified version lt Name gt lt target revision gt Reboot after an update of Dr Web Update Default value is yes If the value is set to no notification that reboot is required will appear Attempt to get the list of IP addresses from update drweb com before updating Can be one of the following e reset all forced update of all components e reset failed reset revision for damaged components Ta yan A A Appendices 105 normal failed try to update all components including damaged from the current revision to the newest or specified update revision try to update all components of the current revision to the newest if exists e normal update all components g proxy arg Proxy server for updating lt address gt lt port gt u user arg Username for proxy server k password arg Password for proxy server param arg Pass additional parameters to the script lt Name gt lt value gt progress to console Print information about downloading and script execution to the console exec command parameters s script arg Execute this script f func arg Execute this function in the script p param arg Pass additional parameters to the script lt Name gt lt value gt progress to console Print information about script execution to the console getcomp
74. iled logging for a Dr Web component select the corresponding check box By default detailed logging is enabled until the first restart of the operating system If it is necessary to log component activity before and after the restart select the Continue detailed logging after restart not recommended check box 3 Save the changes Quarantine settings To configure Quarantine settings click the corresponding Change button You can configure Dr Web Quarantine estimate its size and delete isolated files from a specified logical drive Folders of Quarantine are created separately on each logical drive where suspicious files are found To empty Quarantine 1 To remove all quarantined files on a particular drive select the drive in the list 2 Click Clear and confirm the deletion when prompted Use Advanced settings to select the isolation mode for infected objects detected on portable data carriers By default detected threats are moved to the folder on this data carrier without being encrypted The Quarantine folder is created on portable data carriers only when they are accessible for writing The use of separate folders and omission of encryption on portable data carriers prevents possible data loss Ta J 1 ax 11 Parental Control 11 Parental Control The Parental Control component allows you to restrict access to devices on your computer and both local and web resources You can also set time limits on using th
75. ileges can install Dr Web There are two installation modes of Dr Web anti virus software e The background mode e The usual mode Installation with command line parameters To install Dr Web with command line parameters enter the executable file name with necessary parameters in the command line the parameters affect installation in background mode installation language restart after installation completes and installation of Firewall installFirewall Install Dr Web Firewall lang Language used for the installation The value of this parameter is language code in ISO 639 1 format reboot Restart the computer automatically after installation is complete silent Installation in background mode For example to start background installation of Dr Web with reboot after the process completes execute the following command drweb 1000 win space exe silent yes reboot yes Usual Installation To start usual installation do one of the following e run the file if the installation kit is supplied as a single executable file e insert the company disk into the CD DVD drive if the installation kit is supplied on the disk If autorun is enabled the installation will start automatically If autorun is disabled run the autorun exe file of the installation kit manually The window opens and displays the autorun menu Click Install Follow the instructions of the Installation Wizard At any installation step before the wizard star
76. in Dr Web settings you are prompted to enter the password if you enabled Protect Dr Web settings by password option on the Settings window Dr Web settings are available when run with administrative privileges Centralized settings adjustment allows you to configure main Dr Web settings and settings of all its components except Scanner 10 1 Notifications On this page you can set the types of email notifications or pop ups that appear above the SpIDer Agent icon amp in the notification area Main Desktop Show notifications on the desktop Notificat otific On a Update Network Email Self Protection Send notifications to email Off Cy Dr Web Cloud Anti Virus Network Devices Notification parameters Advanced Pop up notifications Enable the appropriate option to get pop up notifications above the SpIDer Agent icon amp in the Windows notification area Email notifications To configure email notifications enable the Send notifications to email option Ta J 1 ax 10 Main Settings 47 1 Make sure that all the necessary email notifications in the Notification parameters window are selected 2 Click Change The window with email parameters opens 3 Specify the following parameters Email address Enter an email address where to send the notifications SMTP Server Enter the outgoing SMTP server for Dr Web to use when sending email notifications Port Enter the port for Dr Web t
77. ing system General information about your computer Running processes Scheduled tasks Services drivers Default browser Installed applications Policies HOSTS file DNS servers system event log system directories registry branches Winsock providers Network connections Dr Watson logs Performance index 2 Information about Dr Web anti virus solutions 3 Information about the following plug ins Dr Web for IBM Lotus Domino Dr Web for Kerio MailServer Dr Web for Kerio WinRoute Information about Dr Web anti virus solutions is located in Event Viewer in Application and Services Logs Doctor Web 31 T x A ax 7 Update 7 Update The anti virus solutions of Doctor Web use Dr Web virus databases to detect malicious software These databases contain details and signatures for all virus threats known at the moment of the product release With the updates Dr Web receives information required to detect and block new viruses and sometimes to cure the infected files which were considered unrecoverable before From time to time the updates include enhancements to anti virus algorithms in the form of executable files and libraries The experience of Dr Web anti virus protection helps to fix any bugs in software and to update support service and documentation To ensure the virus databases and software algorithms being most up to date Doctor Web provides you with regular updates to virus databases and product compone
78. ion The Block user activity emulation option allows to prevent any automatic changes in Dr Web operation including execution of scripts that emulate user interaction with Dr Web and are launched by the user The Block changing of system date and time option allows to prevent manual and automatic changes of the system date and time as well as of the time zone This restriction is set for all system users The option can improve performance of the time limit function implemented in Parental Control If Internet or computer usage limits are set in Parental Control this option is automatically enabled You can configure notification parameters so that to be informed on attempt to change the system time To restrict access to Dr Web settings on your computer enable the Protect Dr Web settings with a password option in the Settings section 52 Ta AN ax 10 Main Settings 10 5 Dr Web Cloud On this page you can connect to Doctor Web cloud services and take part in Dr Web quality improvement program Main Dr Web Cloud You can connect to cloud services to allow Dr Web anti virus components to use Notifications real time information on threats This information is stored and updated on Doctor Web servers In turn data about Dr Web operation on your computer will Update be automatically sent to Doctor Web servers Network The information obtained from your computer will not be used for your identification or to cont
79. ion with administrator privileges if such session is simultaneously active To set application rules 1 To make a decision consider the following information displayed in the notification Application name The name of the application Ensure that the path to the application executable specified in the Application path entry field corresponds to the file location Application path The full path to the application executable file and its name Digital signature The digital signature of the application Address The used protocol and network address to which the application is trying to connect Port The network port used for the connection attempt Direction The direction of the connection 2 Once you make a decision select an appropriate action e To block this connection once select Block once e To allow this connection once select Allow once e To open a window where you can create a new application filter rule select Create rule In the open window you can either choose one of the predefined rules or create your rule for application 3 Click OK Firewall executes the selected action and closes the notification window A You need administrative privileges to create a rule Ta 2 1 aX In cases when a connection was initiated by a trusted application an application with existing rules but this application was run by an unknown parent process the corresponding notification displays To set parent process ru
80. is optimal to keep information on threats current Update source Specify the update source that suits you best by clicking the Change button e Doctor Web servers recommended This source is selected by default e Local or network folder update from local or network folder where updates have been copied To specify the path to the folder click Browse and select the required folder or enter the address manually Enter the user name and password if necessary e Anti virus Network updates are to be downloaded from a local network computer if Dr Web product is installed and update mirror is created on it Advanced settings Updating components You can choose one of the following ways of downloading the update e All recommended when updates are downloaded both for the Dr Web virus databases and antivirus engine and for other program components of the Dr Web e Only virus databases when only the updates for the Dr Web virus databases and the antivirus engine are downloaded other components of Dr Web are not updating Ta 1 aX 10 Main Settings 50 Update Mirror To allow other local network computers with installed Dr Web products to use your computer as an update source click Change under the Update mirror and in the open window select Create update mirror Specify the path to the folder where updates will be copied If your computer is connected to several networks you can specify IP address available t
81. ized or not For Scanner only di 1 RA lt file log gt append the specified file with the current scanning report By default logging is sabled di J 1 Console Scanner only J REP follow symbolic links while scanning Option is disabled by default RP lt file log gt rewrite the specified file with the current scanning report By default logging is sabled RPC lt sec gt Dr Web Scanning Engine connection timeout Timeout is 30 seconds by default For RPCD use dynamic RPC identification For Console Scanner only RPCE use dynamic RPC endpoint For Console Scanner only 1 RPCE lt target_address gt use specified RPC endpoint For Console Scanner only RPCH lt host_name gt use specified host name for remote call For Console Scanner only RPCP lt protoco gt use specified RPC protocol Possible protocols Ipc np tcp For Console Scanner only SCC show content of complex objects Option is disabled by default SCN show installation package name Option is disabled by default SLS show logs on the screen Option is enabled by default For Console Scanner only SPN show names of packers Option is disabled by default SPS display scan progress on the screen Option is enabled by default For Console Scanner only SST _ display object scan time Option is disabled by default TB check boot s
82. king parameters In the Blocking parameters group you can enable automatic block of URLs due to a notice from the copyright owner for that select the corresponding check box and block of unreliable websites select Block not recommended sites On the Exclusions page you can specify websites access to which must be allowed regardless of other restrictions By default SpIDer Gate blocks access to websites known as infection sources At that applications from the exclusion list are not blocked Programs to block SpIDer Gate can detect and block the following malicious programs e Suspicious e Riskware e Dialers e Hacktools e Adware e Jokes By default SpIDer Gate blocks suspicious programs adware and dialers Objects to block SpIDer Gate can block malformed or not checked objects This option is disabled by default Advances settings You can configure scans of archive and installation packages By default all malicious programs are blocked and scanning of archives and installation packages is disabled 70 Ta J i aX 13 Protection components 71 You can also adjust Scan priority that determines distribution of resources depending on traffic scanning priority Internet connection speed decreases when SpIDer Gate operates with lower priority since the monitor have to wait longer for downloading and scans larger portions of data When you increase the priority SpIDer Gate starts scanning data more often thus
83. les 1 Consider information about the parent process in the notification displayed on a connection attempt 2 Once you make a decision about what action to perform select one of the following e To block this connection once select Block e To allow this connection click Allow e To create a rule for the parent process click Create rule and in the open window specify required settings 3 Click OK Firewall executes the selected action and closes the notification window When an unknown process is run by another unknown process a notification displays the corresponding details If you click Create rule a new window appears allowing you to create new rules for this application and its parent process 13 5 2 Configuring Firewall To access the Firewall settings you are prompted to enter the password if you enabled Protect Dr Web settings by password option on the Settings window To start using Firewall do the following e Select the operation mode e List authorized applications e Configure parameters for known networks By default Firewall operates in training mode Regardless of the operation mode events are logged The default settings are optimal for most uses Do not change them unnecessarily Select the Allow local connections check box to allow all applications on you computer to interconnect i e allow unlimited connections between application installed on your computer For this type of connection no rules a
84. lick Create or Edit This opens a rule creation or rule modification window 2 Configure the following parameters Rule name The name of the created edited rule Description The rule description Action The action for Firewall to perform when the packet is intercepted e Block packets e Allow packets Direction The direction of the connection e Inbound the rule is applied when the packet is received from the network e Outbound the rule is applied when the packet is sent into the network from your computer e Any apply the rule regardless of packet transfer direction Logging The logging mode for the rule This parameter defines which information is stored in the log e Entire packet log the whole packet e Headers only log the packet header only e Disabled no information is logged Criterion Filtering criterion For example transport or network protocol To add a filtering criterion select it from the list and click Add You can add any number of filtering criteria For certain headers there are additional criteria available d If you do not add any criterion the rule will allow or block all packets depending on the setting specified in the Action field For example adding a packet filter rule that allows all packets from a subnetwork may look as follows If you select Any for the Local IP address and Remote IP address fields the rule is applied for any packet which contains an IPv4 header and
85. lick Stop A The Pause button is not available while processes and RAM are scanned Ta yas A A 8 Dr Web Scanner 36 8 2 Neutralizing Detected Threats By default if known viruses or computer threats of other types are detected during scanning Dr Web Scanner informs you about them You can neutralize all detected threats at once by clicking Neutralize In this case Dr Web Scanner applies the most effective actions according to its configuration and threat type Scanning completed Dr Web Scanner detected threats It is highly recommended to neutralize all detected threats immediately Dr Web Scanner will apply actions according to settings Threats detected 327 oe Neuraize Scan time 00 00 13 7 Object Threat Action Path D eicar rar Infected archive Move v C Users TestLab Desktop Acce eicar rar 5 abt Probably MACRO Vir Move v C Users TestLab Desktop Acceptan a txt g gt base64 eml Infected e mail Move v C Users TestLab Desktop Ac base64 eml b 17z Infected archive Move v C Users TestLab Desktop Acceptan 1 7z upx exe Win32 HLLP Jeefo 36 Cure v C Users TestLab Desktop Accep upx exe gt Mailbase Infected e mail Move C Users TestLab Desktop Acce Mailbase A Hide additional information 1 By clicking Neutralize you apply actions to the objects selected in the table Dr Web selects all objects by default once scanning completes When necessary you can customiz
86. ll a program 2 In the open window select the program To delete the program completely click Uninstall and go to step 6 To change the configuration of Dr Web by adding or removing certain components click Change The window of the Installation Wizard opens 3 Installing the program 18 lt 4 Dr WEB English v Removing or changing Dr Web Security Space components E Change components B Configure Dr Web Security Space components according to your needs Restore program e Restore Dr Web anti virus protection on your computer Remove program Remove Dr Web anti virus protection from your computer Doctor Web Ltd 1992 2014 To restore anti virus protection on your computer select Restore program To change the Dr Web configuration click Change components In the open window select check boxes of the components you want to add and clear check boxes of the components you want to remove When you finish adjusting the component set click Install When removing components of Dr Web the Disabling Self protection window opens Enter the displayed confirmation code and click Install To delete all installed components select Remove program In the Parameters window select check boxes of those components that you do not want to remove from your system Saved objects and settings can be used by the program if it is installed again By default all options are selected that is Quarantine Dr Web Security S
87. ls this object is moved to quarantine cured The action is available only for objects infected with a known virus that can be cured except for Trojan programs and files within complex objects Cure delete if not Instructs to restore the original state of an object before infection If the object is cured incurable or the attempt of curing fails this object is deleted The action is available only for objects infected with a known virus that can be cured except for Trojan programs and files within complex objects Delete Instructs to delete the object This action is not available for boot sectors No action is performed on malicious objects for which you selected this action if they are detected in a boot sector Move to Quarantine Instructs to move the object to a specific folder of Quarantine This action is not available for boot sectors No action is performed on malicious objects for which you selected this action if they are detected in a boot sector Ignore Instructs to skip the object without performing any action or displaying a notification The action is available only for potentially dangerous files adware dialers jokes hacktools and riskware Ta yan A A 13 Protection components 67 SpIDer Guard does not check complex objects No action is performed on such objects or files within them Copies of all processed objects are stored in Quarantine Scan Mode In this group you can set up what
88. m filter Messages included within the email body are not analyzed 2 Send the message with the attachment to one of the following addresses e If the attached message is detected as spam incorrectly send the email to vrnonspam drweb com e If the attached messages is an undetected spam send it to vrspam drweb com Ta J i ax 13 Protection components 78 13 5 Dr Web Firewall Dr Web Firewall protects your computer from unauthorized access and prevents leak of vital data through networks It monitors connection attempts and data transfer and helps you block unwanted or suspicious connections both on network and application levels Firewall provides you with the following features e Control and filtration of all incoming and outgoing traffic e Access control on the application level e Filtration if packets on the network level e Fast selection of rule sets e Event logging 13 5 1 Training Firewall By default once installation completes Firewall starts learning usual behavior of your operating system by intercepting all new unknown to the firewall connection attempts and prompting you to select the necessary action You can either select a temporary solution or create a rule which will be applied each time Firewall detects this type of connection When running under limited user account Guest Dr Web Firewall does not prompt requests for network access attempts Notifications are then forwarded to the sess
89. m messages 0 On the Dr Web Anti Virus page the current protection status is displayed enabled disabled This page also provides access to the following program functions e Log allows to configure the program logging Ta J 1 aX 13 Protection components e Check attachments allows to configure email check and to specify program actions on detection of malicious objects e Spam filter allows specifying program actions on spam detection and creating black and white lists of email addresses e Statistics allows viewing the number of checked and processed objects 13 6 2 Threat Detection Dr Web for Outlook uses different detection methods Infected objects are processed according to the actions defined by the user the program can cure such objects remove them or move these objects to Quarantine to isolate them from the rest of the system Types of Threats Dr Web for Outlook detects the following malicious objects e Infected objects e Bomb viruses in files or archives e Adware Hacktools Dialer programs Joke programs Riskware e Spyware Trojan horses Trojans e Computer worms and viruses Configuring Actions Dr Web for Outlook allows to specify program reaction to detection of infected or suspicious files and malicious objects in email attachments To configure virus check of email attachments and to specify program actions for detected malicious objects in the Micr
90. n all anti virus components are operating with their default settings SpIDer Mail detects viruses and suspicious objects distributed via email first and prevents them from infiltrating into your computer SpIDer Mail operation is rather resource sparing scanning of email files can be performed without other components 72 Ta yan A A 13 Protection components 73 13 3 1 Configuring SpIDer Mail To access the SpIDer Mail settings you are prompted to enter the password if you enabled Protect Dr Web settings by password option on the Settings window The default settings are optimal for most uses Do not change them unnecessarily Scan Options The following settings allow you to configure additional mail scanning parameters e Heuristic analysis in this mode special methods are used to detect suspicious objects infected with unknown viruses with high probability To disable the analyzer clear the Heuristic analysis recommended check box e Check of installation packages This option is disabled by default Protection Scan options Components Use heuristic analysis recommended On G SpIDer Guard Scan installation packages SpIDer Gate off SpIDer Mail Actions Anti spam Infected Firewall E Cure move to quarantine if not cured recommended Preventive Protection Suspicious Move to quarantine recommended Advanced settings Actions By default SpIDer Mail attempts to
91. nd modified viruses which use the known infection mechanisms Thus Dr Web users are protected against such threats as notorious blackmailer Trojan Encoder 18 also known as gpcode In addition to detection of new and modified viruses the Origins Tracing mechanism allows to considerably reduce the number of false triggering of the heuristics analyzer Objects detected using the Origins Tracing algorithm are indicated with the Origin extension added to their names Execution emulation The technology of program code emulation is used for detection of polymorphic and encrypted viruses when the search against checksums cannot be applied directly or is very difficult to be performed due to the impossibility of building secure signatures The method implies simulating the execution of an analyzed code by an emulator a programming model of the processor and runtime environment The emulator operates with protected memory area emulation buffer in which execution of the analyzed program is modelled instruction by instruction However none of these instructions is actually executed by the CPU When the emulator receives a file infected with a polymorphic virus the result of the emulation is a decrypted virus body which is then easily determined by searching against signature checksums Heuristic analysis The detection method used by the heuristics analyzer is based on certain knowledge heuristics about certain features attributes than might
92. nd nationwide corporations Dr Web antivirus solutions are well known since 1992 for continuing excellence in malware detection and compliance with international information security standards State certificates and awards received by the Dr Web solutions as well as the globally widespread use of our products are the best evidence of exceptional trust to the company products We thank all our customers for their support and devotion to the Dr Web products y AN ax Table of Contents 1 Introduction 1 1 About This Manual 1 2 Document Conventions 1 3 Detection Methods 2 System Requirements 3 Installing the program 3 1 Installation Procedure 3 2 Removing or changing the program 4 Licensing 4 1 Activation method 4 2 Renewing License 4 3 Registration Wizard 4 3 1 Starting activation 4 3 2 Registration data entry 4 3 3 Activation results 5 Getting Started 5 1 How to Test Anti virus 6 Tools 6 1 License Manager 6 2 Data Loss Prevention 6 3 Anti virus Network 6 4 Quarantine Manager 6 5 Support 6 5 1 Report 7 Update 8 Dr Web Scanner 8 1 Scanning Your System 8 2 Neutralizing Detected Threats 8 3 Scanner Settings 8 4 Scanning in Command Line Mode Oo oo N 11 12 13 17 19 19 20 20 21 21 21 22 24 25 25 26 27 28 30 30 32 33 33 36 38 42 Ta AN A v A Y 8 5 Console Scanner 8 6 Automatic Launch of Scanning 9 Settings 10 Main Settings 10
93. nd of viruses rootkits Trojans spyware adware hacktools and all possible types of malicious objects from any external source The module architecture of Dr Web is its significant feature The anti virus engine and virus databases are common for all components and different operating environments At present in addition to Dr Web products for Windows there are versions of anti virus software for IBM OS 2 Novell NetWare Macintosh Microsoft Windows Mobile Android Symbian and several Unix based systems Linux FreeBSD Solaris Dr Web uses a convenient and efficient procedure for updating virus databases and program components via the Internet Dr Web can detect and remove undesirable programs adware dialers jokes riskware and hacktools from your computer To detect undesirable programs and perform actions with the files contained in the programs anti virus components of Dr Web are used Each of the Dr Web anti virus solutions for Microsoft Windows operating systems includes a set of the following components Dr Web Scanner Scanner is an anti virus scanner with graphical interface The program runs on user demand or as scheduled and checks the computer for viruses Dr Web Console Scanner a command line version of Dr Web Scanner SpIDer Guard is an on access anti virus scanner that constantly resides in memory while scanning files and RAM on the fly and instantly detects any malicious activi
94. network access for the application without displaying any notification to the user If filtering rules for the application are set Firewall processes the connection according to the specified actions Allow unknown connections In this mode Firewall allows all unknown applications to access network recourses including the Internet No notification on access attempt is displayed Rules for Applications Application level filtering helps you control access of various applications and processes to network resources as well as enable or disable applications to run other processes You can create rules for both system and user applications A Firewall allows you to create no more than one set of rules per each application This page lists all applications and processes for which there is an application filter rule set You can create new filter rule sets as well as edit the existing ones or delete those that are unnecessary Each application is explicitly identified by the path to its executable file Firewall uses the SYSTEM name to indicate the rule set applied to the operating system kernel the system process for which there is no unique executable file d If the file of an application for which the rule was created changes e g an update was installed Firewall prompts to confirm that the application is still allowed to access network resources If you created a blocking rule for a process or set Block unknown connections mode and then
95. not match active connections according to the TCP protocol specification This option helps protect your computer from DoS attacks denial of service resource scanning data injection and other malicious operations It is also recommended to enable stateful packet filtering when using complex data transfer protocols FTP SIP etc Clear this check box to filter packets without regard to the TCP session state Select this check box to ensure correct processing of large amounts of data The maximum transmission unit MTU may vary for different networks therefore large IP packets may be fragmented When this option is enabled the rule selected for the first fragment of a large IP packet is applied to all other fragments Clear this check box to process fragmented packets independently The Edit rule set window lists packet filtering rules for the selected rule set You can configure the list by adding new rules or modifying existing rules and the order of their execution The rules are applied according to their order in the set For each rule in the set the following information displays Enabled Action Rule name Direction Logging Description Edit rule set Status of the rule The action for Firewall to perform when the packet is intercepted e Block packets e Allow packets The rule name The direction of the connection e G the rule is applied when the packet is received from the network e E the rule is appli
96. nts which are distributed via the Internet Dr Web Update helps you download and install the updates during the licensed period Update start During update Dr Web downloads and installs all updated files that correspond to your version of Dr Web and upgrades Dr Web when a newer version is released For Dr Web to update you need a connection to the Internet to the update mirror local or network folder or to the Anti virus network with at least one computer that has an update mirror set All necessary parameters can be defined on the Update page of Dr Web Main settings Start from the SpIDer Agent menu Click the SpIDer Agent icon amp and select Updater This opens an information on relevance of Dr Web virus databases and other components as well as the date of their last update Start updating by clicking Update Start from the command line Open the Dr Web installation folder YPROGRAMFILES Common Files Doctor Web Updater and run the drwupsrv exe file The list of command line parameters can be found in Appendix A Automatic start If launched automatically Dr Web installs updates silently and logs all changes into the dwupdater log file located in the allusersprofile Doctor Web Logs folder After an update of executable files drivers or libraries a program restart may be required In such cases an appropriate warning displays 32 A y 8 Dr Web Scanner 8 Dr Web Scanner By default Dr Web Scanner c
97. ny difficulties with Dr Web products we recommend using the Support following tools My Dr Web Help Dr Web forum Report for technical support If you encounter any questions take advantage of the following tools My Dr Web Opens you personal account of Doctor Web company site There you can get your license information license period serial number renew your license ask a question to the support and more Help Opens help file Dr Web forum Opens the Dr Web forum at http forum drweb com Report for technical support Launches the wizard that will help you to create a report containing important information on your system configuration and computer working If you have not found solution for the problem you can request direct assistance from Doctor Web technical support by filling in the web from in the corresponding section of the support site at http support drweb com For regional office information visit the Doctor Web official website at http company drweb com contacts moscow 6 5 1 Report When contacting Doctor Web technical support you can generate a report on your operating system and Dr Web operation The report will be stored as an archive in the Doctor Web subfolder of the USERPROFILE folder 30 Ta J 1 ax 6 Tools To generate a report click the corresponding button The report will include the following information 1 Technical information about the operat
98. o computers of only one network You can also specify the port for HTTP connections 10 3 Network Proxy Server By default all components use direct connection mode If necessary you can enable use of a proxy server and specify its connection settings To do that click Change The window with proxy server parameters opens Address Specify the address of the proxy server Port Specify the port of the proxy server User Specify the username to use when connecting to the proxy server Password Specify the password to use when connecting to the proxy server under the provided username Authorization type Select an authorization type required to connect to the proxy server Secure Connections You can enable scanning of data transmitted over secure protocols To check such data select the Check encrypted traffic check box If your client application that uses secure connections does not refer to the default Windows system certificate storage then you need to export the certificate Notifications Update Network Self Protection Dr Web Cloud Anti Virus Network Devices Advanced Doctor Web Certificate 10 Main Settings Proxy server Use proxy server off Cm Secure connections Check encrypted traffic Off Cm If error occurs during checking SSL connections install Doctor Web certificate Export You may need to scan data transmitted in accordance with SSL protocol For instance you can configur
99. o the exclusions The access to the listed websites will be allowed but the sites will be still checked for viruses By default the list is empty If you add a website to the white list users will be able to access it regardless of other SpIDer Gate settings Please note that if the site is added both to the black list of the Parental Control and to the exclusions access will be blocked To configure black and white lists 1 Enter a domain name or a part of a domain name for the website that you want to access regardless of other restrictions e To add a certain website enter its name for example www example com This allows access to all webpages located on this website To allow access to websites with similar names enter the common part of their domain names For example if you enter example then SpIDer Gate will allow access to the example com example test com test com example test example222 com and other similar websites To allow access to websites within a particular domain enter the domain name with a period character This allows access to all webpages located on this website If the domain name includes a forward slash the substring before the slash is considered a domain name while the substring after the slash is considered a part of address for the websites that you want to access within this domain For example if you enter example com test SpIDer Gate will allow access to webpages such as example com testi1
100. o use when connecting to the mail server Login Enter the login for Dr Web to use when connecting to the mail server Password Enter the password for the login which is used when connecting to the mail server Security Select the security level for connections to the mail server Authentication Select the authentication method to be used when connecting to the mail server 4 Click Test to send a test message using the provided connection parameters If you do not receive the message within several minutes check the provided connection details 5 After editing click OK to save the changes or Cancel to cancel them Notifications parameters Notifications parameters Notification type Desktop Email Threat detected y Major v Critical v Minor v v Do not show notifications in full screen mode v Display Firewall notifications on separate desktop in full screen mode OK Cancel Q 1 Click Notification parameters The window listing available notifications opens Select types of notifications that you want to receive and select the corresponding check boxes To display pop up notifications select check boxes in the Desktop column To receive mail notifications select the check boxes in the Email column 3 If necessary configure additional parameters Ta ww aX 10 Main Settings 48 Do not show notifications in full screen mode Display Firewall notifications on separate desktop in full screen mo
101. od you receive the same key file as during the previous registration providing that the validity period is not expired A demo period can be reactivated only on the computer where the registration procedure was run If you reinstall the product or install it on several computers if the license allows for that you will be able to use the previously registered key file You can use the key file obtained during the first registration The number of requests for a key file receipt is limited One serial number can be registered not more than 25 times If more requests are sent the key file will not be delivered In this case to receive a lost key file contact technical support describing your problem in detail stating your personal data input during the registration and the serial number The key file will be sent by technical support to your email address 4 2 Renewing License When the license expires or characteristics of the protected system change you may need to renew or extend the license If so you should change the current key file Dr Web supports hot license update without stopping or reinstalling the product To change a license key file 1 Open License Manager You can also purchase a new license or renew an existing one on your personal page on the Doctor Web official site To visit your page use My Dr Web option in the License Manager or SpIDer Agent menu amp 2 If the current key file is invalid Dr Web automatically
102. ollowing error standard info extended debug Directory where repository and settings are located Directory for storing the log file Log file name Repository directory lt data_dir gt repo by default Enable tracing Command to execute getversions getcomponents getrevisions init update uninstall exec downloadm and keyupdate Zones that are to be used instead of those specified in the configuration file init command parameters s version arg p product arg a path arg n component arg u user arg k password arg g proxy arg e exclude arg Version name Product name Product directory path This directory will be used as the default directory for all components included in the product Dr Web Update will search for a key file in this directory Component name and installation folder specified as follows lt name gt lt install path gt Username for proxy server Password for proxy server Proxy server for updating lt address gt lt port gt Component name that will be excluded from the product during installation update command parameters p product arg n component arg x selfrestart arg yes geo update type arg normal Product name If specified only this product will be updated If neither product nor certain components are specified all products will be updated If certain components are spec
103. omputers allowed for simultaneous anti virus check A valid key file satisfies the following criteria e License is not expired e Integrity of the key file is not violated If any of the conditions is violated the key file becomes invalid and Dr Web stops detecting and neutralizing malicious programs in files memory and email messages If during Dr Web installation a key file was not received and no path to it was specified a temporary key file is used Such a key file provides full functionality of Dr Web However on the SpIDer Agent menu My Dr Web and Update items are not available until you either activate a license or demo period or specify a path to the valid key file via License Manager It is recommended to keep the key file until the license or demo period expires A key file for a demo period activation can be used only on the computer where the registration procedure was run 4 1 Activation method You can activate your license or a demo period in one of the following ways e Using the Registration Wizard during installation or later e Obtaining the key file during registration on the Doctor Web official website Ta J 1 aX 4 Licensing e Specifying the path to the valid key file residing on your computer during installation or in the License Manager window Reactivating License You may need to reactivate a license or demo period if the key file is lost When reactivating a license or a demo peri
104. on for Unchecked messages and then scan the moved file with Dr Web Scanner d If you want to disable scans of email by SpIDer Mail ensure that SpIDer Guard monitors your computer constantly After performing reaction you configured SpIDer Mail can display a notification in the notification area If necessary you can configure desktop and email notifications Actions on Messages In this group you can configure additional actions to apply when SpIDer Mail processes messages Insert X Antivirus This option is enabled by default decal tle Instructs SpIDer Mail to add scan results and information on Dr Web version to g message headers after processing You cannot edit data format Delete modified Instructs to remove messages to which Delete or Move to Quarantine action was applied messages on the by SpIDer Mail The messages are removed from mail servers regardless of the mail server client settings Scanning Optimization Options You can set the condition under which SpIDer Mail should acknowledge too complicated messages whose scanning is time consuming as unchecked To do that enable the Message scan timeout option and set the maximum message scanning time After the expiry of the specified period SpIDer Mail stops check of the message Scanning archives Enable the Scan archives option if you want SpIDer Mail to scan the archived files transferred via email The following parameters will be available to cofigure e Ma
105. onents command parameters s version arg Version name p product arg Specify the product to get the list of components that are included in this product If the product is not specified all components of this version will be listed getrevisions command parameters s version arg Version name n component arg Component name uninstall command parameters n component arg Name of the component that is to be uninstalled progress to console Print information about command execution to the console param arg Pass additional parameters to the script lt Name gt lt value gt e add to exclude Components to be deleted Update of this components will not be performed Ta N ax Appendices 106 keyupdate command parameters m md5 arg o output arg b backup g proxy arg u user arg k password arg progress to console MD5 hash of the previous key file Output file name to store new key Backup of an old key file if exists Proxy server for updating lt address gt lt port gt Username for proxy server Password for proxy server Print information about downloading of the key file to the console download command parameters zones arg key dir arg l progress to console g proxy arg u user arg k password arg s version arg p product arg Zone descri
106. onnection to your Dr Web on the Anti virus Network page in Main settings 27 Ta N ax 6 Tools 28 6 4 Quarantine Manager Quarantine Manager provides the information about the Quarantine component which serves for isolation of files that are suspicious as malware Quarantine also stores backup copies of files processed by Dr Web Use the Quarantine Manager settings to select the isolation mode for infected objects detected on portable data carriers When this option is enabled detected threats are moved to the folder on this data carrier without being encrypted The Quarantine folder is created only when the data carrier is accessible for writing The use of separate folders and omission of encryption on portable data carriers prevents possible data loss To open this window click the SpIDer Agent icon amp in the notification area select Tools and then select Quarantine Manager Tools Quarantine Manager License Manager E Data Loss Prevention Objects Threat Date added Path An Virus Network E hacktool exe Tool HideApp 14 03 23 10 2014 C windows Quarantine Manager E dialer unp Dialer Adultparty 14 03 23 10 2014 C program files Support H eicar com EICAR Test File 14 03 23 10 2014 C program files Moved SYSTEM Created 14 03 23 10 2014 Size 24 0 KB Modified 14 03 23 10 2014 With threads 24 0 KB Accessed 14 03 23 10 2014 Threat Tool HideApp Added 14 03 23 10 2014 Keep permanen
107. or disable Dr Web components Data Loss Prevention Anti Virus Network E A WIN81X64RU IP address 192 168 21 197 Quarantine Manager SpIDer Guard On Anti spam Off SpIDer Gate On Parental Control On SpIDer Mail Off Self protection On Firewall On Preventive On protection Support Last update 22 10 2014 13 37 m WIN7X86RU IP address 192 168 21 252 To access a remote anti virus select the computer in the list and click Connect Enter password specified in the settings of the remote anti virus An icon for the remote SpIDer Agent ke2 appears in the notification area and the notification about established connection will be prompted You can view settings enable or disable components and configure their settings Anti virus Network Quarantine Manager and Scanner are not available Dr Web Firewall settings and statistics are not available as well but you can enable or disable this component if you accessed Dr Web Anti virus for Windows or Dr Web Security Space Also you can select the Disconnect item to terminate the remote connection If the required computer is not on the list you can try to add it manually For this click and enter an IP address You can establish only one connection with a remote Dr Web product If one connection is already established the Connect button is disabled Computers are listed if Dr Web products installed on these computers allow remote connection You can allow c
108. osoft Outlook mail application in the Tools Options Dr Web Anti virus page for Microsoft Outlook 2010 in the Files Options Add ins section select Dr Web for Outlook then click the Add in Options button click Check attachments 88 Ta 2 i aX 13 Protection components 89 Check attachments Check settings i Infected Not cured Suspicious Malware Adware Dialers Jokes Hacktools Riskware IF check failed Cure Move to quarantine Move to quarantine Move to quarantine Move to quarantine Move to quarantine Move to quarantine Move to quarantine Move to quarantine V Check archives recommended Cancel Apply The Check attachments window is available only for users with administrative privileges For Windows Vista and later operating systems after clicking Check attachments e If UAC is enabled administrator is requested to confirm program actions user without administrative privileges is requested to enter accounting data of system administrator e If UAC is disabled administrator can change program settings user does not have the permission change program settings In the Check attachments window specify actions for different types of checked objects and also for the check failure You can also enable disable check of archives To set actions to be applied on threat detection use the following
109. overy of affected objects that is return of the object s structure and operability to the state which was before the infection if it is possible Not all malicious programs can be cured However products of Doctor Web are based on most effective curing and file recovery algorithms Move to quarantine an action when the malicious object is moved to a special folder and isolated from the rest of the system This action is preferable in cases when curing is impossible and for all suspicious objects It is recommended to send copies of such files to the virus laboratory Doctor Web of for analysis Delete the most effective action for neutralizing computer threats It can be applied to any type of malicious objects Note that deletion will sometimes be applied to certain files for which curing was selected This will happen if the file contains only malicious code and no useful information For example curing of a computer worm implies deletion of all its functional copies Block rename these actions can also be used for neutralizing malicious programs In the former case all access attempts to or from the file are blocked In the latter case the extension of the file is renamed which makes it inoperative 111 Ta J N ax Appendices Appendix C Naming of Viruses When Dr Web components detect a threat the notification in the user interface and the report file contain a name of the threat sample given by the speciali
110. pace settings and Protected copies of files Click Next In the next window confirm deletion of Dr Web by entering the displayed code and then click Remove program When prompted restart the computer to complete the procedure A AN T v A A 4 Licensing 19 4 Licensing To use Dr Web for a long period of time activate a license You can purchase a license with the product or on the Doctor Web official website A license allows to take advantage of all product features during the whole period Parameters of the license key file are set in accordance with the software license agreement If you want to evaluate the product before purchasing it you can activate a demo period It provides you with full functionality of the main components but the period of validity is considerably restricted A You can activate a demo period for the same computer no more than once a year Demo period is available for e 3 months For that register on the Doctor Web official website and receive a serial number e 1 month For that purpose no serial number is required and no registration data is requested Key File The use rights for the Dr Web are specified in the key file The key file has the key extension and contains the following information e List of licensed anti virus components e Licensed period for the product e Availability of technical support for the user e Other restrictions for example the number of remote c
111. ption file Directory where the key file is located Print information about command execution to the console Proxy server for updating lt address gt lt port gt Username for proxy server Password for proxy server Version name Name of the product to download Ta 1 ax Appendices 107 Return codes The values of the return code and corresponding events are as follows 0 OK no virus found 1 Known virus detected 2 Modification of known virus detected 4 Suspicious object found 8 Known virus detected in file archive mail archive or container 16 Modification of known virus detected in file archive mail archive or container 32 Suspicious file found in file archive mail archive or container 64 At least one infected object successfully cured 128 At least one infected or suspicious file deleted renamed moved The actual value returned by the program is equal to the sum of codes for the events that occurred during scanning Obviously the sum can be easily decomposed into separate event codes For example return code 9 1 8 means that known viruses were detected including viruses in archives mail archives or containers curing and others actions were not executed no other virus events occurred during scanning Ta AN ax Appendices Appendix B Computer Threats and Neutralization Methods With the development of computer technologies and network solutions malicious program
112. r suspicious files and archives or other malicious objects e The Exclusions page where you can specify files and folders to be excluded from scanning e The Log page where you can set logging options for Dr Web Scanner e The Restore defaults page where you can restore the Dr Web Scanner settings to their default values 4 For details on settings specified on each page use the Help 2i button 5 After editing click OK to save the changes or Cancel to cancel them Main Page On this page you can set general parameters of Dr Web Scanner operation TEDE B Main Actions Exclusions Log Restore defaults F if Use sound alerts F Automatically apply actions to threats E C Turn off computer after scanning F Interrupt scanning when switching to battery mode Limits on use of computer resources to 50 recommended v T aX A AN 8 Dr Web Scanner 39 Use sound alerts Automatically apply actions to threats Turn off computer after scanning Enable Dr Web Scanner to use sound alerts for every event Select to enable Dr Web Scanner to apply actions to detected threats automatically Select to turn off the computer after scanning If Automatically apply actions to threats is selected Dr Web Scanner will apply the specified actions to detected threats Interrupt scanning when switching to battery mode Select to interrupt scanning when switching to battery mo
113. re applied Clear this check box to apply rules for connections carried out both through the network and within your computer After a session under a limited user account Guest is open Firewall displays an access error message Firewall status is then displayed as inactive in SpIDer Agent However Firewall is enabled and operates with default settings or settings set earlier in Administrative mode 13 Protection components 79 13 Protection components Protection Dr Web Firewall operation mode Components Create rules for known applications automatically SpIDer Guard Allow local connections fe et SpIDer Gate SplDer Mail Change network access for the applications Change working parameters for the known networks Anti spam Firewall Preventive Protection Operation modes Select one of the following operation modes e Allow unknown connections free access mode when all unknown applications are permitted to access networks e Create rules for known applications automatically mode when rules for known applications are created automatically set by default e Interactive learning mode training mode when the user is provided with full control over Firewall reaction e Block unknown connections restricted access mode when all unknown connections are blocked For known connections Firewall applies the appropriate rules Create rules for known applications automatically In this mod
114. rental Control module the password is required if you set Protect Dr Web settings by password check box on the Settings window Configuring Parental Control module parameters for different users The parameters of the Office Control are applied to all the users of the computer where the Dr Web Agent is installed In the main part of the window you can view the specified settings By default access to the Internet and to the local resources is not restricted no time limits are set A If necessary you can configure desktop and email notifications on Parental Control actions Internet By default the No restrictions mode is set for all users To change these settings select another mode in the drop down list Block by categories In this mode you can select categories of websites to block You can also add websites to the manually populated black and while lists to block or allow access to the resources regardless of other restrictions Block all except websites from the white list In this mode you grant access to the websites in the white list only Access to any other website is blocked Safe search In any mode except the No restrictions mode you can enable the Safe search option to manage results of the search engines This option allows to exclude unwanted webpages from search results Time On this page you can set restrictions on time spent on the Internet or working on the computer By default users have unlimited acce
115. reset However if the worm s body infiltrates the computer then only an anti virus program can cope with it Worms have the ability to cripple entire networks even if they do not bear any payload that is do not cause any direct damage due to their intensive distribution Trojans This type of malicious program cannot reproduce or infect other programs A Trojan substitutes a high usage program and performs its functions or imitates the programs operation At the same time it performs some malicious actions in the system damages or deletes data sends confidential information etc or makes it possible for another person to access the computer without permission for example to harm the computer of a third party A Trojan s masking and malicious facilities are similar to those of a virus and it can even be a component of a virus However most Trojans are distributed as separate executable files through file exchange servers removable data carriers or email attachments which are launched by a user or a system task Rootkits It is a type of malicious program used to intercept system functions of an operating system in order to conceal itself Besides a rootkit can conceal tasks of other programs registry keys folders and files It can be distributed either as an independent program or a component of another malicious program A rootkit is basically a set of utilities which a cracker installs on a system to which she had ju
116. ring rules control interaction of a particular application with certain network hosts To create a rule Configure the following parameters General Rule name The name of the created edited rule Description The rule description Action The action for Dr Web Firewall to perform when an attempt to connect to the Internet is detected e Block packets block the connection e Allow packets allow the connection State Rule status e Enabled the rule is applied for all matching connections e Disabled the rule is temporary not applied Direction The direction of the connection e Inbound the rule is applied when someone from the network attempts to connect to an application on your computer e Outbound the rule is applied when an application on your computer attempts to connect to the network e Any apply the rule regardless of packet transfer direction Logging Logging mode e Enabled register events e Disabled no information is logged Rule Settings Protocol The network and transport level protocols used for the connection attempt Local address Remote address Local port Remote port The following protocols of the network level are supported e IPv4 e IPv6 e IP all any version of the IP protocol The following protocols of the transport level are supported e TCP e UDP e TCP amp UDP TCP or UDP protocol e RAW The IP address of the remote host You can specify either a certain addres
117. rmation on threat detection License expiration notifications a message is registered in 30 15 7 3 2 and 1 days before expiration To view Windows Event Log 1 Open the Control Panel of the operating system 2 Select Administrative Tools Event Viewer 3 In the tree view select Application The list of events registered in the log by user applications will open The source of Dr Web for Outlook messages is Dr Web for Outlook Debug Text Log The following information is registered in the debug log e License validity status e Information on threat detection Read write errors or errors occurred while scanning archives or password protected files parameters of program modules scanner engine virus databases Core failures License expiration notifications a message is registered in 30 15 7 3 2 and 1 days before expiration Configure logging 1 On the Dr Web Anti virus tab click Log The window with the logging settings opens 2 To set the maximum detalization for the logging enable the Detailed logging flag By default logging is set to regular mode Ta i ax 13 Protection components The maximum detalization for the logging decreases server performance therefore it is recommended to enable detailed logging only in case an error in operation of Dr Web for Outlook occurs 3 Click OK to save changes 95 Ta J i ax 13 Protection components 96 The Log window is available
118. rojan Backdoor Trojan with RAT function Remote Administration Tool a utility for remote administration IRC Trojan which uses Internet Relay Chat channels DownLoader Trojan which secretly downloads different malicious programs from the Internet MulDrop Trojan which secretly downloads different viruses contained in its body Proxy Trojan which allows a third party user to work anonymously in the Internet via the infected computer StartPage synonym Seeker Trojan which makes unauthorized replacement of the browser s home page address start page Click Trojan which redirects a user s browser to a certain website or websites KeyLogger a spyware Trojan which logs key strokes it may send collected data to a malefactor AVKi11 terminates or deletes anti virus programs firewalls etc KillFiles KillDisk DiskEraser deletes certain files all files on drives files in certain directories files by certain mask etc DelWin deletes files vital for the operation of Windows OS FormatcC formats drive C synonym FormatA11 formats all drives 1MBR corrupts or deletes master boot records MBR MOS corrupts or deletes CMOS memory a z N Q Tool for Attacking Vulnerabilities Exploit a tool exploiting known vulnerabilities of an OS or application to implant malicious code or perform unauthorized actions 113 Ta AN ax Appendices
119. rs to receive updates of the virus database and other program files as well as automatically install them SpIDer Agent is a utility that lets you set up and manage Dr Web components 7 Ta i ax 1 Introduction 1 1 About This Manual This User Manual describes installation and effective utilization of Dr Web You can find detailed descriptions of all graphical user interface GUI elements in the Help system which can be accessed from any component This User Manual describes how to install the program and contains some words of advice on how to use it and solve typical problems caused by virus threats Mostly it describes the standard operating modes of the Dr Web components with default settings The Appendices contain detailed information for experienced users on how to set up Dr Web Due to constant development program interface of your installation can mismatch the images given in this document You can always find the actual documentation at http download drweb com doc 1 2 Document Conventions The following symbols and text conventions are used in this guide Bold Names of buttons and other elements of the graphical user interface GUI and required user input that must be entered exactly as given in the guide Green and bold Names of Doctor Web products and components Green and underlined Hyperlinks to topics and webpages Monospace Code examples input to the command line and application outp
120. rs whose messages are delivered or blocked by SpIDer Mail automatically that is without analyzing their contents If you add an address to the white list messages from the sender will be always delivered to recipients If you add an address to the black list all messages from the sender will be regarded as spam automatically i e without scanning By default both lists are empty To configure anti spam lists 1 Enter an address or a mask for addresses of senders whose email messages you want to process automatically without analysis e To add a certain sender enter the full email address for example name mail com This ensures automatic processing of all messages from this sender without analysis Ta J 1 ax 12 Exclusions e To add senders with similar usernames replace the differing part of their addresses with an asterisk and a question mark Use an asterisk to substitute any character sequence or a question mark to substitute any single character For example if you enter name mail com SpIDer Mail will process automatically messages from name mail com namei mail com name_of_name mail com and senders with other similar usernames e To process automatically all messages sent from any email address within a domain use an asterisk instead of the username in the address For example to specify all messages sent from any email address within the pochta ru domain enter pochta ru 2 To ad
121. rvices which allow anti virus components to use the latest information on threats This information is stored and updated on Doctor Web servers in real time mode By default SpIDer Guard loads automatically when Windows starts and cannot be unloaded during the current Windows session 13 1 1 Configuring SpIDer Guard To access the SpIDer Guard settings you are prompted to enter the password if you enabled Protect Dr Web settings by password option on the Settings window The default settings are optimal for most uses Do not change them unnecessarily Background Rootkit Scanning Anti rootkit component included in Dr Web provides options for background scanning of the operating system for complex threats and curing of detected active infections when necessary If this option is enabled Dr Web Anti rootkit constantly resides in memory In contrast to on the fly scanning of files by SpIDer Guard scanning for rootkits includes checking of autorun objects running processes and modules Random Access Memory RAM MBR VBR disks computer BIOS system and other system objects One of the key features of the Dr Web Anti rootkit is delicate attitude towards consumption of system resources processor time free RAM and others as well as consideration of hardware capacity When Dr Web Anti rootkit detects a threat it notifies you on that and neutralizes the malicious activity 65 Ta 1 ax 13 Protection components Durin
122. s Equals or several IP addresses using a range In range specific subnet mask Mask or masks of all subnets in which your computer has a network address MY_NETWORK To apply the rule for all remote hosts select Any The port used for the connection You can specify either a specific port number Equals or a port range In range To apply the rule for all ports select Any Ta i A v 4 Y 13 Protection components 84 Rules for Networks On the Interfaces page you can select a rule set to use for filtering packets transmitted through a certain network interface installed on your computer To set rule sets for network interfaces 1 In the Firewall settings window select Interfaces 2 For the required interface select the appropriate rule set If the appropriate rule set does not exist you can create a new set of packet filtering rules 3 Click OK to save the changes To list all available interfaces click Show all This opens a window where you can select interfaces that are to be permanently listed in the table Active interfaces are listed in the table automatically To configure rules for interfaces click Configure Packet filtering allows you to control access to network regardless of what program initiates the connection These rules are applied to all network packets transmitted through a network interface of your computer Thus packet filtering provides you with more general mechanisms to
123. s e Get demo e Activate license e Purchase license If you have a serial number for activation of a license or a demo period for 3 months select Activate license Enter the serial number and click Next e If you enter a serial number for activation of a demo period for 3 months a window with activation results opens e If you enter a serial number for activation of a license the registration data entry window opens If you have already been a user of Dr Web you are eligible for extension of your new license for A another 150 days To enable the bonus enter your serial number and specify the path to the previous key file in the open window If you do not have a serial number and want to evaluate functionality of the product you can activate a demo period for 1 month by selecting Get demo Click Next A window with the activation results opens To purchase a license from Doctor Web online store click Purchase license If you already have a valid key file click Other activation types In the window displayed specify the file path 4 3 2 Registration data entry To register a license enter personal data your registration name and email address select the country and enter the city name All the fields listed are obligatory and must be filled in If you want to receive news of Doctor Web by email select the corresponding check box Click Next 4 3 3 Activation results If the activation procedure completed successfully
124. s file containers Trojan programs are deleted on detection This is the only action available for boot sectors Instructs to move the object to a specific folder for isolation This action is not available for boot sectors No action is performed on malicious objects for which you selected this action if they are detected in a boot sector Instructs to delete the object This action is not available for boot sectors No action is performed on malicious objects for which you selected this action if they are detected in a boot sector Instructs to skip the object without performing any action or displaying a notification The action is available only for potentially dangerous files adware dialers jokes hacktools and riskware Threats within complex objects archives email attachments file containers cannot be processed individually For such threats Dr Web Scanner applies an action selected for this type of a complex object Exclusions Page On this page you can specify files and folders to be excluded from scanning 40 7 oF 8 Dr Web Scanner 41 x ERB O Main Actions Exclusions Log Restore defaults Files and folders excluded from scanning Browse Add Name Delete Scan contents of the following files Archives F E mail files Installation packages Here you can list names or masks for the files to be excluded from scanning All files with the names which match the name or mask sp
125. s malware of different kinds meant to strafe users become more and more widespread Their development began together with computer science and facilities of protection against them progressed alongside Nevertheless there is still no common classification for all possible threats due to their unpredictable development character and constant improvement of applicable technologies Malicious programs can be distributed through the Internet local area networks email and portable data mediums Some of them rely on the user s carelessness and lack of experience and can be run in completely automatic mode Others are tools controlled by a computer cracker and they can harm even the most secure systems This chapter describes all of the most common and widespread types of malware against which products of Doctor Web are aimed Classification of Computer Threats Computer Viruses This type of malicious programs is characterized by the ability to implement its code into the executable code of other programs Such implementation is called infection In most cases the infected file becomes a virus carrier itself and the implemented code does not necessarily match the original Most viruses are intended to damage or destroy data on the system Viruses which infect files of the operating system usually executable files and dynamic libraries and activate upon launching of the infected file are called file viruses Some viruses infect boot records of
126. sibly infected and the type of a possible virus according to the classification of the heuristic analyzer is displayed Click an arrow on this button to select a custom action for a detected threat by default Dr Web Scanner offers the most effective action You can apply the displayed action separately to each threat by clicking this button The full paths to the corresponding files If you selected Automatically apply actions to threats check box on the Main page Dr Web Scanner will neutralize threats automatically Ta 1 aX 8 Dr Web Scanner 38 8 3 Scanner Settings When using Windows Vista or later operating systems it is recommended to run Dr Web Scanner under an account with administrative privileges The default settings are optimal for most uses Do not change them unnecessarily To configure Scanner settings 1 Click the SpIDer Agent icon amp and select Scanner The menu of quick access to different modes of scan opens 2 Click the Custom item The Dr Web Scanner window opens Express and Full items run corresponding modes of scan in this modes settings are not available till the scan is stopped or completed 3 Click the Settings icon amp on the toolbar This opens the window which contains several pages e The Main page where you can configure general parameters of Dr Web Scanner operation e The Actions page where you can configure reaction of the Dr Web Scanner on detection of infected o
127. sion RunOnce e Software Microsoft Windows CurrentVersion RunOnceEx e Software Microsoft Windows CurrentVersion RunOnce Setup e Software Microsoft Windows CurrentVersion RunOnceEx Setup e Software Microsoft Windows CurrentVersion RunServices e Software Microsoft Windows CurrentVersion RunServicesOnce Autorun of policies e Software Microsoft Windows CurrentVersion Policies Explorer Run Safe mode configuration e SYSTEM ControlSetXxx Control SafeBoot Minimal Ta ww ax 13 Protection components 99 e SYSTEM ControlSetXXX Control SafeBoot Network Session Manager parameters e System ControlSetXXX Control Session Manager SubSystems Windows System services e System CurrentControlXXX Services d If any problems occur during installation of important Microsoft updates or installation and operation of programs including defragmentation programs temporarily disable preventive protection A If necessary you can configure desktop and email notifications on preventive protection actions A yan Aq A Y Appendices 100 Appendices Appendix A Command Line Parameters Additional command line parameters switches are used to set parameters for programs which can be launched by opening an executable file This relates to Dr Web Scanner Console Scanner and Dr Web Update The switches can set parameters that are either not present in the configuration file or have a higher priority than those specified in the file
128. ss to use the computer and the Internet 60 Ta J i ax 11 Parental Control To set time limits 1 Select days of week and time when the user is restricted from accessing the Internet and then mark the corresponding timeslots blue Methods e To mark one timeslot click on it once e To mark several adjacent timeslots click the first slot once and select the rest of required squares while holding the mouse button 2 Select days of week and time when the user is restricted from using the computer and then mark the corresponding timeslots red Methods e To mark one timeslot double click it e To mark several adjacent timeslots double click the first one and select the rest of required timeslots while holding the mouse button Setting time limits for using the computer or Internet automatically enables the Block changing of system date and time option on the Self protection page of the main settings Files and folders By default the No restrictions mode is set for all users To change these settings enable the appropriate option and add the objects to which you want to block access Please note that access blocking is not guaranteed when loading the computer from external locations or connecting from other operating systems 61 Ta J 1 ax 12 Exclusions 12 Exclusions 12 1 Websites If you want to have access to the websites that are not recommended to visit by the Doctor Web company add them t
129. st gained access There are two kinds of rootkits according to the mode of operation User Mode Rootkits UMR which operate in user mode intercept functions of the user mode libraries and Kernel Mode Rootkits KMR which operate in kernel mode intercept functions on the level of the system kernel which makes it harder to detect 109 Ta AN ax Appendices Hacktools Hacktools are programs designed to assist the intruder with hacking The most common among them are port scanners which detect vulnerabilities in firewalls and other components of the computer s protection system Besides hackers such tools are used by administrators to check the security of their networks Occasionally common software which can be used for hacking and various programs that use social engineering techniques are designated as among hacktools as well Spyware This type of malicious programs is designed to perform monitoring of the system and send the gathered information to a third party creator of the program or some other person concerned Among those who may be concerned are distributors of spam and advertisements scam agencies marketing agencies criminal organizations industrial espionage agents etc Spyware is secretly loaded to your system together with some other software or when browsing certain HTML pages and advertising windows It then installs itself without the user s permission Unstable browser operation and decrease in s
130. sts of the Dr Web Virus Laboratory These names are formed according to certain principles and reflect a threat s design classes of vulnerable objects distribution environment OS and applications and some other features Knowing these principles may be useful for understanding software and organizational vulnerabilities of the protected system The full and constantly updated version of this classification is available at http vms drweb com classification In certain cases this classification is conventional as some viruses can possess several features at the same time Besides it should not be considered exhaustive as new types of viruses constantly appear and the classification is made more precise The full name of a virus consists of several elements separated with full stops Some elements at the beginning of the full name prefixes and at the end of it suffixes are standard for the accepted classification Prefixes Affected Operating Systems The prefixes listed below are used for naming viruses infecting executable files of certain operating systems e Win 16 bit Windows 3 1 programs e Win95 32 bit Windows 95 98 Me programs e WinNT 32 bit Windows NT 2000 XP Vista programs e Win32 32 bit Windows 95 98 Me and NT 2000 XP Vista programs e Win32 NET programs in Microsoft NET Framework operating system e OS2 OS 2 programs e Unix programs in various Unix based systems e Linux Linux programs e
131. t Component Antirootkit The central table lists the following information on quarantined objects that are available to you e Object name of the quarantined object e Threat malware class of the object which is assigned by Dr Web when the object is moved to Quarantine e Date added the date and time when the object was moved to Quarantine e Path full path to the object before it was quarantined Quarantine displays objects which can be accessed by your user account To view hidden objects you need to have administrator privileges In the Quarantine Manager window the following buttons are available e Restore move file to the selected folder and specify a new file name Ta 1 ax A Use this option only when you are sure that the selected objects are not harmful e Delete delete file from the quarantine and from the system To delete all objects from quarantine click and select Delete all in the drop down menu 6 Tools 29 1 ax A AN 6 Tools 6 5 Support This section provides information on the product version components the last update date and the useful links that may help you to resolve issues or solve problems encountered while using Dr Web Tools About Version 10 0 License Manager Last update 09 09 2014 10 16 04 00 il Data Loss Prevention Das Anti Virus Network Assistance in resolving problems Quarantine Manager If you encounter a
132. tect users against spam messages with HTML code linked to online content Semantic analysis The words and phrases of a message both visible to the human eye and hidden are compared with words and phrases typical of spam using a special dictionary Anti scamming Scam as well as pharming messages is the most dangerous type of spam including so called Nigerian scams loan scams lottery and casino scams and false messages from banks and credit organizations A special module of Dr Web Anti spam is used to filter scams Technical spam Bounces are delivery failure messages sent by a mail server Such messages are also sent by a mail worm Therefore bounces are as unwanted as spam Protection Scan mode Co m pone nts Check mail for spam On E SpIDer Guard Allow Cyrillic text SpIDer Gate o EDO SpIDer Mail Allow Asian text Anti spam On a Firewall Add the prefix to subjects of spam messages Preventive Protection On SPAM SpIDer Mail adds the X DrWeb SpamState header to each checked message SpIDer Mail scans incoming messages for spam by default To deliver messages without scanning disable the corresponding option You can select messages that should not be regarded as spam automatically and configure the way to mark filtered email 76 Ta yan A A Y 13 Protection components 77 Add the following By default this option is enabled and SpIDer Mail adds
133. tement wantto connect to services recommended will decide later Doctor Web 1992 2014 Click Next 5 The Installation Wizard informs you that a license is required for Dr Web operation 3 Installing the program 15 lt 6 Dr WEB English Registration Wizard To take full advantage of Dr Web Security Space license is required Receive license during installation Receive license later D Specify path to an available valid key file Browse Doctor Web 1992 2014 Do one of the following e if a key file is present on the hard drive or removable media click Specify path to an available valid key file and select the file in the open window To change the path click Browse and select another key file e If you want to receive a key file during the installation select Receive license during installation e To continue installation without a license select Receive license later Updating is not available until you have obtained a key file Click Next 6 The window opens notifying you that the product is ready to be installed To start installation with the default parameters click Install To select components you want to install specify the installation path and set additional parameters click Installation parameters The option is meant for experienced users 7 If you selected Install at the previous step go to the description of step 10 Otherwise the Installation param
134. the SPAM prefix to the Subject prefix to subjects of field of all spam messages Sea eS Instructs SpIDer Mail to add a special prefix to the subjects of spam messages Using a prefix allows you to create filter rules for spam in those mail clients for example Microsoft Outlook Express where it is not possible to enable filtering by headers White and Black lists Click to list senders whose messages you want to deliver or regard as spam automatically Processing Mail by Spam Filter SpIDer Mail adds the following header to the processed messages e X DrWeb SpamState lt value gt where lt value gt indicates whether the message is considered by SpIDer Mail as spam Yes or not No e X DrWeb SpamVersion lt version gt where lt version gt indicates Dr Web Anti spam version e X DrWeb SpamReason lt spam rate gt where lt spam rate gt includes list of evaluations on various spam criteria You can use these headers and the prefix in the Subject field if selected to configure email filtering with your mail client If you use IMAP NNTP protocols configure your mail client to download complete messages from mail server at once i e without previewing their headers This is required for correct operation of the spam filter To improve performance of the spam filter you can report errors in spam detection To report spam detection errors 1 Create a new email and attach the message that was processed incorrectly by the spa
135. ts copying files to your computer you can do the following e Return to the previous step by clicking Back e Go to the next step by clicking Next e Abort installation by clicking Exit Installing Dr Web 1 If other anti virus software is installed on your computer the Installation Wizard informs you on incompatibility between Dr Web and another anti virus product and offers to remove it Before the installation starts the Wizard checks if the installation file is the latest one If newer installation file exists you will be offered to download it before the installation Ta AN ax 3 Installing the program 14 2 Read the license agreement To continue installation you must accept its terms and click Next Click Next 3 At the next step you will be offered to install Dr Web Firewall Click Next 4 At this step you are prompted to connect to Dr Web cloud services that allow the anti virus components to use the newest information which is stored and updated on Doctor Web servers 36 Dr WEB English Dr Web Cloud You can connect to cloud services to allow Dr Web anti virus components to use real time information on threats This information is stored and updated on Doctor Web servers In turn data about Dr Web operation on your computer will be automatically sent to Doctor Web servers The information obtained from your computer will not be used for your identification or to contact you Privacy sta
136. ty SpIDer Mail the program intercepts calls sent from mail clients to mail servers through POP3 SMTP IMAP4 NNTP protocols IMAP4 stands for IMAPv4revi and detects and neutralizes mail viruses before a mail message is received by the mail client or before a mail message is sent to the mail server SpIDer Mail also provides you with spam filtering by using Dr Web Anti spam Dr Web for Outlook is a plug in that checks Microsoft Outlook mail boxes for viruses and spam SpIDer Gate is an HTTP monitor By default the component automatically checks incoming HTTP traffic and blocks all malware objects URL filtering of malicious and unreliable websites is also enabled by default You can also connect to Doctor Web cloud services which allow anti virus components to use the latest information on threats This information is stored and updated on Doctor Web servers in real time mode Parental Control is used to restrict access to websites files and folders and allows to set custom time limits on using your computer and the Internet for different Windows accounts You can also connect to Doctor Web cloud services which allow anti virus components to use the latest information on threats This information is stored and updated on Doctor Web servers in real time mode Dr Web Firewall is a components that protects your computer from unauthorized access and prevents vital data from leaking through networks Dr Web Update allows registered use
137. ut Italic Placeholders which represent information that must be supplied by the user For command line input it indicates parameter values CAPITAL LETTERS Names of keys and key sequences Plus sign Indicates a combination of keys For example ALT F1 means to hold down the ALT key while pressing the F1 key Exclamation mark A warning about potential errors or any other important comment 8 Ta J i ax 1 Introduction 1 3 Detection Methods The Doctor Web anti virus solutions use several malicious software detection methods simultaneously and that allows them to perform thorough checks on suspicious files and control software behavior Detection Methods Signature analysis The scans begin with signature analysis which is performed by comparison of file code segments to the known virus signatures A signature is a finite continuous sequence of bytes which is necessary and sufficient to identify a specific virus To reduce the size of the signature dictionary the Dr Web anti virus solutions use signature checksums instead of complete signature sequences Checksums uniquely identify signatures which preserves correctness of virus detection and neutralization The Dr Web virus databases are composed so that some entries can be used to detect not just specific viruses but whole classes of threats Origins Tracing On completion of signature analysis the Dr Web use the unique Origins Tracing method to detect new a
138. ware programs are not only those which can accidentally damage or delete data but also ones which can be used by crackers or some malicious programs to do harm to the system Among such programs are various remote chat and administrative tools FTP servers etc 110 Ta AN aX Appendices Below is a list of various hacker attacks and Internet fraud Brute force attack performed by a special Trojan horse program which uses its inbuilt password dictionary or generates random symbol strings in order to figure out the network access password by trial and error DoS attack denial of service or DDoS attack distributed denial of service a type of network attack which verges on terrorism It is carried out via a huge number of service requests sent to a server When a certain number of requests is received depending on the server s hardware capabilities the server becomes unable to cope with them and a denial of service occurs DDoS attacks are carried out from many different IP addresses at the same time unlike DoS attacks when requests are sent from one IP address Mail bombs a simple network attack when a big email or thousands of small ones is sent to a computer or a company s mail server which leads to a system breakdown There is a special method of protection against such attacks used in the Dr Web products for mail servers Sniffing a type of network attack also called passive tapping of network
139. was sent from a physical address of the local computer Ta 2 N ys 13 Protection components 87 13 6 Dr Web for Outlook Main Functions Dr Web for Outlook plug in performs the following functions e Anti virus check of incoming email attachments e Check of email attachments transferred over encrypted SSL connections e Spam check Detection and neutralization of malware Heuristic analysis for additional protection against unknown viruses 13 6 1 Configuring Dr Web for Outlook You can set up parameters of plug in operation and view statistics on Microsoft Outlook mail application in the Tools Options Dr Web Anti virus page for Microsoft Outlook 2010 in the Files Options Add ins section select Dr Web for Outlook and click the Add in Options button The Dr Web Anti virus page of Microsoft Outlook settings is active only if the user has permissions to change these settings Options EE Preferences Mail Setup Mail Format Speling Other Dr Web Anti virus General g Dr Web Anti virus is enabled Log Anti virus and anti spam check A Infected attachments may present a threat to your information security fa Check attachments amp Spam messages are unsolicited bulk e mails a Anti spam filter Statistics app Checked 0 Clear 0 B Infected 0 Moved to quarantine 0 Suspicious 0 Deleted 0 Cured 0 Ignored 0 Not checked 0 Spa
140. ximum file size to extract If an archive size exceeds the specified value SpIDer Mail does not unpack and check the archive e Maximum compression ratio the maximum compression ratio of an archive If an archive compression ratio exceeds the specified value SpIDer Mai does not unpack and check the archive Ta i ax 13 Protection components 75 e Maximum archive nesting level the maximum nesting level for archived files If a nesting level is greater than the specified value SpIDer Mail proceeds unpacking and scanning the archive until this limit is exceeded To enable one or more options select the corresponding check boxes A There is no restrictions for a parameter if the value is set to 0 Ta N ax 13 Protection components 13 4 Anti spam Dr Web Anti spam Dr Web Anti spam technologies consist of several thousand rules that can be divided into several groups Heuristic analysis A highly intelligent technology that empirically analyzes all parts of a message header message body and attachments if any Detection of evasion techniques This advanced anti spam technology allows detecting evasion techniques adopted by spammers to bypass anti spam filters HTML signature analysis Messages containing HTML code are compared with a list of known patterns from the anti spam library Such comparison in combination with the data on sizes of images typically used by spammers helps pro
141. ystem performance are common side effects of spyware presence Adware Usually this term is referred to a program code implemented into freeware programs which perform forced display of advertisements to a user However sometimes such codes can be distributed via other malicious programs and show advertisements in Internet browsers Many adware programs operate with data collected by spyware Jokes Like adware this type of malicious programs does not deal any direct damage to the system Joke programs usually just generate message boxes about errors that never occurred and threaten to perform actions which will lead to data loss Their purpose is to frighten or annoy a user Dialers These are special programs which are designed to scan a range of telephone numbers and find those where a modem answers These numbers are then used to mark up the price of telephoning facilities or to connect the user to expensive telephone services All the above programs are considered malicious because they pose a threat to the user s data or his right of confidentiality Programs that do not conceal their presence distribute spam and different traffic analyzers are usually not considered malicious although they can become a threat under certain circumstances Among other programs there is also a class of riskware programs These were not intended as malicious but can potentially be a threat to the system s security due to their certain features Risk

Download Pdf Manuals

image

Related Search

Related Contents

TP-Link TL-WN722NC Declaration of Conformity  NOTICE Before using this product, read the entire  Notice  JVC Arsenal KD-LH1150 CD Player  参考資料 3-1  manuale dell'utento  TANDBERG D14041.02 User's Manual    USB to Printer Cable User`s Manual V2.4 _  

Copyright © All rights reserved.
Failed to retrieve file