1.   To release the Data Hold function and return the meter to normal operation  press  the    Hold Backlight    key again  The word HOLD will switch off  The backlight function  illuminates the display and is used when the ambient light to too low to permit viewing  of the displayed readings  Press the Data Hold  amp  Backlight button for 2 second to  turn the backlight on and press the button a second time to turn the backlight off     Peak Hold  only ACA 200A Range   The Peak Hold function captures the peak AC DC current 10 282 8A  The meter can  capture peaks as fast as  lt 1 0 millisecond in duration     MAX MIN  DCA DCV ACV  Resistance range    1  Press the MAX MIN key to activate the MAX MIN recording mode  The display  icon  MAX  will appear  The meter will display and hold the maximum reading  and will update only when a new    max    occurs    2  Press the MAX MIN key and    MIN    will appear The display icon  MIN  will appear   The meter will display and hold the minimum reading and will update only when a  new    min    occurs   3  Press the MAX MIN key and a    MAXMIN    will appear  The meter will display the  present reading  but will continue to update and store the max and min readings    4  To exit MAX MIN mode press and hold the MAX MIN key for 2 seconds     DCA ZERO    The DC Zero feature removes offset values and improves accuracy for DC current  measurements  To perform a zero  select ADC and with no conductor in the jaw     1  Press the DC ZERO button 2 S
2. DA    A fo Jr     VOL         of Instruments     WWW VOLTH NET    Instruction manual       Safety  International Safety Symbols    A e This symbol  adjacent to another symbol or terminal  indicates the user  must refer to the manual for further information   IN e This symbol  adjacent to a terminal  indicates that  under normal use   hazardous voltages may be present   E e Double insulation                SAFETY NOTES   e Do not exceed the maximum allowable input range of any function  e Do not apply voltage to meter when resistance function is selected   e Set the function switch OFF when the meter is not in use     WARNINGS   e Set function switch to the appropriate position before measuring    e When measuring volts do not switch to current resistance modes    e When changing ranges using the selector switch always disconnect the test leads  from the circuit under test    e Do not exceed the maximum rated input limits     CAUTIONS   e Improper use of this meter can cause damage  shock  injury or death  Read and  understand this user manual before operating the meter    e Always remove the test leads before replacing the battery    e Inspect the condition of the test leads and the meter itself for any damage before  operating the meter  Repair or replace any damage before use    e Use great care when making measurements if the voltages are greater than 25VAC  rms or 35VDC  These voltages are considered a shock hazard    e Remove the battery if the meter is to be stored for 
3. ec  to zero the display     ZERO    will appear in the  display  The offset value is now stored and removed from all measurements    2  To view the stored value  press the DC ZERO button     ZERO    will flash and the  stored value will be displayed    3  To exit this mode  press and Hold the ZERO button until    ZERO    is no longer in  the display     True RMS  ACA or ACV   The term stands for    Root Mean Square     which represents the method of  calculation of the voltage or current value  Average responding multimeters are  calibrated to read correctly only on sine waves and they will read inaccurately  on non sine wave or distorted signals  True rms meters read accurately on  either type of signal     Battery Replacement  1  Remove the one rear Phillips head screw  2  Open the battery compartment  3  Replace the Requires two    AAA    batteries  UM4 R03   4  Re assemble the meter       VOLTH    
4. inuity Measurements  1  Insert the black test lead into the negative COM terminal and the    red test lead into the positive terminal    2  Touch the test probe tips across the circuit or component under  test  It is best to disconnect one side of the device under test so  the rest of the circuit will not interfere with the resistance reading     3  For Resistance tests  read the resistance on the LCD display  amp  if the resistance is  lt  30Q  a  tone will sound     Non Contact AC Voltage Measurements    WARNING   Risk of Electrocution  Before use  always test the Voltage Detector  on a known live circuit to verify proper operation    1  Touch the probe tip to the hot conductor or insert into the hot side of the  electrical outlet   2  If AC voltage is present  the detector light will illuminate        NOTE   The conductors in electrical cord sets are often twisted  For best results   rub the probe tip along a length of the cord to assure placing the tip in  close proximity to the live conductor    NOTE   The detector is designed with high sensitivity  Static electricity or other  sources of energy may randomly trip the sensor  This is normal operation    Flashlight  Press and hold the top button to turn the flashlight on  Release the button to turn the  flashlight off     Data Hold  amp Backlight button   To freeze the current reading on the LCD  press the    Data Hold  amp  Backlight    key    The word HOLD will appear on the LCD while the meter is in the Data Hold mode  
5. long periods    e Always discharge capacitors and remove power from the device under test before  performing Diode  Resistance or Continuity tests    e Voltage checks on electrical outlets can be difficult and misleading because of  theuncertainty of connection to the recessed electrical contacts  Other means  should be used to ensure that the terminals are not  live     e  f the equipment is used in a manner not specified by the manufacturer  the  protection provided by the equipment may be impaired                    Input Limits  Function Maximum Input  AAC  ADC 200A  PEAK 282 8A   V DC  VAC 600V DC AC  Resistance  Continuity Test 600V DC AC                Meter Description    9    ONDAN          Current clamp  amp  Non contact AC voltage detector probe tip    Flashlight    Non contact AC voltage NCV  indicator light      Flashlight on off button    Rotary Function swith      Clamp trigger    LCD display    Select Peek hold  MAX MIN Hold  DCA Zero DC ACV function button Peak Hold    function  only ACA range  DCA Zero  only DCA range  MAX MIN Hold function   Use to DCA DCV ACV  Resistance range   DC ACV  select DC Vor ACV    Data Hold  amp  Backlight button    10  COM input jack  11  V Q jack  12  Battery Cover                                  1  AC DC AC  alternating current  and DC  direct currrent    2  mm Minus sign   3  1 8 8 8 2000 to 9999 count measurement reading   4  PEAK  MAXMIN PEAK MAX MIN mode   5      Audible Continuity N   6  HOLD Data Hold mode al   7  BAT L
6. ow Battery icon Ai   8 VAU Units of measure list     J   Specifications   Function Range  amp  Resolution Accuracy    of reading    AC Current  50 60 Hz  True RMS 200 0 AAC    2 5    8 digits    DC Current 200 0 ADC    2 0    5 digits    DC Voltage 600 0 VDC    1 0    2 digits    AC Voltage  50 60 Hz  True RMS 600 0 VAC    1 5   8 digits    Resistance 999 9 Q    1 5   8 digits   Clamp size Opening 0 7   18mm  approx    Continuity Check   Low Battery Indication  Overrange Indication  Measurements Rate    Input Impedance  Display   AC Current bandwidth  AC Voltage bandwidth  Peak hold   Max Min hold  Operating Temperature  Storage Temperature  Relative Humidity  Altitude   Over voltage   Battery   Auto Power Off APO     Dimensions Weight  Safety    Threshold  lt 30Q  Test current  lt  0 5mA       BAT    is displayed      OL    is displayed   10 times Sec  for reading  amp  32 segments bar graph updates 40  times  at DCA DCV 8 Resistance Measurement     1 0MQ  VDC and VAC    2000 counts to 9999 counts LCD display with backlight  50 400Hz  True rms    50 400Hz  True rms    Captures peaks  lt 10ms   Captures times  lt 50ms   14 to 122  F   10 to 50  C     14 to 140  F   30 to 60  C    90  0  C to 30  C   75  30  C to 40  C   45  40  C to 50  C   Operating  3000m  Storage 10 000m   Category III 600V  Category IV 300V   Two 1 5V    AAA    Batteries   Without pressing any function buttons is approx  10 minutes APO   Pressing any function buttons is disable APO   164x65x32mm 175g   Fo
7. r indoor use and in accordance with the requirements for double  Insulation to IEC1010 1  1995   EN61010 1  1995  Overvoltage Category  III 600V and Category IV 300V  Pollution Degree 2        Operation             NOTICES  Read and understand all warning and precaution statements listed in the safety  section of this operation manual prior to using this meter  Set the function select  switch to the OFF position when the meter is not in use           AC Current Measurements  1  Set the Function switch to the ACA range     2  Press the jaw trigger and clamp around  fully enclosing a single conductor  Do not allow a  gap between the two halves of the jaw  Refer to the diagram at right for the correct way to  enclose a single conductor        3  Read the ACA value on the LCD     Yes  DC Current Measurements  1  Set the Function switch to the DCA range   2  Press the DCA ZERO key to null the meter display   No    3  Press the Trigger to open the current sense Jaw     4  Fully enclose the conductor to be measured  Do not allow a gap between the two  halves of the jaw     5  Read the DCA value on the LCD     ao Voltage Measurements    Insert the black test lead into the negative COM terminal and the    red test lead into the positive V terminal     Set the function switch to the V position     Press AC  DC button 2 Sec  Select AC DC     Connect the test leads in parallel to the circuit under test     ok wn      Read the voltage measurement on the LCD display     Resistance and Cont
    
Download Pdf Manuals
 
 
    
Related Search
 Manual  manual  manualslib  manual car  manual water pump  manual hoist  manual pallet jack  manuale digitale  manually meaning  manual timesheet  manual transmission  manual wheelchair  manually update your device drivers windows  manual arts high school  manual for courts martial  manual definition  manual j load calculation  manual labor  manual lawn mower  manual muscle testing  manually register devices with autopilot  manual muscle testing grades  manualidades  manual transfer switch  manual therapy cpt code  manual blood pressure cuff 
    
Related Contents
USB ポータブルデータロガー ALG-250/ALGE  Amana PGB58B Slow Cooker User Manual  advertencia - Hitachi Koki    Panasonic PT-TW240U Operating Instructions  Brookstone GRILL GAUGE User's Manual  690KB - 日立国際電気  Kenmore 25 cu. ft. Side-by-Side Refrigerator - Black Energy Guide  User Manual      Copyright © All rights reserved. 