1. TEST ETHERNET DATABASE VERSION RCD PART NUMBER SCALE NONE SIZE A DWG omputer Status LED Dataload Status LED FIGURE 3 Data load Status LED PDA69000940 301 REV 5 SHEET 17
2. DATE APPROVED CAGE CODE 97896 SCALE NONE SIZE A DWG NO PDA69000940 301 REV SHEET 2 HIF 1472R5 Table of Contents 1 0 Sl iel u i 4 2 0 Reference Drawings Documents 4 3 0 General inforrati iii a E E E 4 31 USB Flash Drive i i 4 3 2 CD ROM ARINC 615A Data Loader System Object Media eere 5 4 0 Application Software and Databases 6 4 2 Application Software and Databases Media Base Part 6 5 0 Software and Databases Loading Procedures eese nennen nnns 7 5 1 Loading Software and Databases on the Aircraft Using a USB Flash Drive 7 5 2 Loading Software and Databases Using ARINC 615A Compatible Data Loader System 8 5 3 MKV A Software Media Installation Verification 2 2 4 4 2222222 4 2 14 CAGE CODE 97896 SCALE NONE SIZE A DWGNO PDA69000940 30 REV SHEETS HIF 1472R5 1 0 PURPOSE This procedure provides generic instructions for loading Application Software Terrain Reloadable Customer Definitions RCDs and Aircraft Personality Databases into the MKV A EGPWS using a USB FLASH Drive with Software Media loaded or ARIN
3. ARINC 615A DATALOADER Icon to start the application e Put your initials in the USER NAME e Select the Aircraft Tail Number or chose 200 as the Tail Number Select 615A LOADER STANDARD IP Address 172 24 90 12 for the connection type Click CONTINUE 97896 SCALE NONE SIZE A DWG PDA69000940 301 REV SHEET 9 HIF 1472R5 8 Click UPLOAD e Select EGPWS 1 as target e Click CONTINUE e Select the model and tail number that you selected when installing the software Load see paragraph 5 2 4 e Selecting ANY MODEL and ANY TAIL NUMBER will display all installed software loads e Select the folder with the desired Software Media to be installed into the EGPWS e Click CONTINUE e Click CONTINUE UPLOAD e The MKV A Software Media should begin loading 9 The DATALOAD STATUS LED will sequence as follows during loading DATALOAD STATUS LED will be Yellow during Application Code loading e The MKV A will reboot e The DATALOAD STATUS LED will be Yellow after MKV A fully reboots e When finished the DATALOAD STATUS LED will be Green After the Software Media is finished loading the MKV A will reboot 11 After 25 seconds maximum the COMPUTER STATUS LED should be illuminated Green 12 The EXTERNAL FAULT LED will be OFF could be Yellow if required external signal is missing 13 Click on Close to close the A
4. A DWG NO PDA69000940 301 REV SHEET 7 HIF 1472R5 5 2 Loading Software Databases Using 615 Compatible Data Loader Svstem 5 2 1 Loading Software Media using a non Teledvne PMAT 2000 Data Loader Svstem NOTE Since there are manv different ARINC 615A compatible Data Loader Svstems commercially available it is not practical to try and provide all the different instructions needed to load MKV A Software Media into the EGPWS using these units Therefore follow the manufactures instructions for the particular ARINC 615A compatible Data Loader System being used 5 2 1 1 Obtain a CD ROM Disc with the desired MKV A Application Software or Terrain Database Object Media part number from Table 4 1 and download it into the non Teledyne A RINC 615A compatible Data Loader System per instructions of paragraph 5 2 3 After the Software Media is installed into the Data Loader perform the following 1 2 3 9 Make sure the circuit breaker is in and the power to the EGPWS is on Open the door on the EGPWS front panel Verify the MKV A EGPWS Front Panel LED status as follows DATALOAD STATUS LED is OFF COMPUTER STATUS LED is Green EXTERNAL FAULT LED is OFF could be Yellow if required external signal is missing Connect an Cat 5 Ethernet cable to the Data Loader System and connect the other end of the Ethernet cable into the DATA LOAD port at the front panel of the MKV A Following the manufactur
5. seconds the ST sequence stops 97896 SCALE NONE SIZE A DWG NO PDA69000940 301 REV E SHEET 14 97896 SCALE NONE SIZE A DWG PDA69000940 301 REV E SHEET 15 HIF 1472R5 JER EXTERNAL FAULT EXTERNAL FAULT LED STAT COMPUTER STATUS LED SELF TEST BUTTON USB MEDIA PORT ee insert USB Media into this port ELFTEST para ff KOAD DATA LOAD ETHERNET PORT Connect ARINC 615 Data Loader to this port 1EADPHONES a 600 AUDIO HEADPHONE JACK EST ETHERNET DATABASE VERSION PART NUMBER FIGURE 1 Status LEDs and USB Data load Port HIF 1472R5 97896 TRUCTIONS FOR DATALOADING 1 Verify COMPUTER STATUS LED is GREEN 2 INSERT the USB Drive the DATALOAD STATUS LED turn YELLOW When completed DATALOAD STATUS LED will turn GREEN 4 Remove the USB Drive Unit will REBOOT Verify COMPUTER STATUS LED is GREEN PROCEDURE COMPLETE LOAD OR US RCD PART NUMBER EXTERNAL FAULT COMPUTER STATUS PRESS TO SELF TEST DATA LOAD 1 HEADPHONES TEST ETHERNET FIGURE 2 Data load In Progress SCALE NONE SIZE A DWG NO PDA69000940 301 omputer Status LED Dataload Status LED SB Media REV 16 HIF 1472R5 97896 IE PWS EXTERNAL FAULT COMPUTER STATUS TO SELF TEST DATA LOAD
6. 00 ARINC 615A Data Loader System into the MKV A EGPWS The instructions found in this section are correct as of the date of the writing of this procedure but mav be subject to change in the future due to software updates to the Data Loader Svstem When following this procedure alwavs refer to the manufactures instructions which take precedence over these instructions 5 2 2 1 Obtain a CD ROM Disc with the desired MKV A Application Software or Terrain Database Object Media part number from Table 4 1 and download it into the Teledyne ARINC 615A compatible Data Loader System per instructions of paragraph 5 2 4 After the Software Media is installed into the Data Loader perform the following 1 Connect the PMAT 2000 Data Ethernet Adaptor Cable to the PMAT 2000 at the rear panel of the unit refer to Table 4 1 2 Open the door on the EGPWS front panel 3 Referring to Figure 1 connect a Cat 5 Ethernet cable to the end of the Adaptor Cable and connect the other end into the DATA LOAD port at the front panel of the MKV A Energize the PMAT 2000 and start the DEMO Systems PMAT 2000 program Make sure the circuit breaker is in and the power to the EGPWS is on Verify the MKV A EGPWS Front Panel LED status as follows DATALOAD STATUS LED is OFF e COMPUTER STATUS LED is Green e EXTERNAL FAULT LED is OFF could be Yellow if required external signal is missing 7 Atthe PMT 2000 DEMO Systems program main menu double click on the
7. C 615A compatible Data Loader System This procedure assumes that software and databases will be loaded into the MKV A on the aircraft 2 0 Reference Drawings Documents Reference Document Number Document Drawing Nomenclature 2 1 1 69000940 End Item EGPWS 115 VAC 2 1 2 69000941 End Item EGPWS 28 VDC 2 1 3 69000942 End Item EGPWS 115 VAC 2 1 4 SWM69000940 803 User Manual for the APD Tool of the MKV A Enhanced Ground Proximity Warning System 2 1 5 SYS69000940 700 MKV A Enhanced Ground Proximity Warning System Interface Control Document 2 1 6 SWM69000940 000 Version Description Document for the Application Software of the MKV A Enhanced Ground Proximity Warning System 2 1 7 DM69001801 0000 Version Description Document for the MKV A Terrain Obstacle and Runway Database 2 1 8 SWM69900070 000 Version Description Document for the Reloadable Customer Definitions RCD Production Builds 2 1 9 SWM69002464 000 Version Description Document for the Aircraft Personality Database APD Production Builds of the MKV A Enhanced Ground Proximity Warning System 3 0 General Information 3 1 USB Flash Drive The software media listed in Table 4 1 comes pre loaded on a USB Flash Drive device This media may be copied onto a different USB Flash Drive The USB Flash Drive should have a capacity of at least 1 Gbyte The formatting of the Drive is important Be sure to follow the procedure of paragrap
8. PN 80425 9 PMAT 2000 Installation Boot 1 98571 Disc Media PN 82155 03 PC Card Emulator EGPWS 1 98571 SW PNs Loader Engine Installer 82184 Ver C 82186 Ver C 82199 Ver A Media PN 82160 03 PC Card Emulator EGPWS 1 98571 SW PN 82183 Ver Reader Installer 5 2 4 2 Obtain MKV A the desired Software Object Media CD ROM from Table 5 1 5 2 4 3 Download the CD ROM Disc contents into the Data Loader System using the following steps 1 Energize and boot up the 2000 ARNIC 615A Data Loader System following manufactures instructions and start the DEMO Systems PMAT 2000 program 2 If not done so already create the directory C datafiles NEWLOADS on the 2000 3 Insert the CD ROM Disc with Software Media files into the CD ROM drive of the PMAT 2000 4 Copy the folder with the Software Media to be installed on the CD ROM to the CidatafilestiNEWLOADS directory 5 Atthe DEMO Systems 2000 program menu double click the LOADSTAR application program Icon to start the application CAGE CODE 97896 SCALE NONE SIZE A DWG NO PDA69000940 301 REV SHEET 12 HIF 1472R5 6 Navigate to the LIBRARY tab 7 Click INSTALL SOFTWARE 8 Choose to get Loads from NEWLOADS directory 9 Check the box next to the Software Media Load previously copied that need to be installed and click NEXT 10 Check the box next to the load in the SOFTWARE LOAD PART NUMBER column 11
9. PRODUCTION Release 06 2014 13 19 21 MST Printed 10 2014 APPLICATION TITLE SHEET DASH NEXT ASSY INDEX SHEET NO 69000940 TITLE SHEET INCLUDES REVISION DESCRIPTION 1 69000941 TABLE OF CONTENTS 3 69000942 DOCUMENT 4 REVISIONS ALL SHEETS ARE SAME REVISION STATUS Initial Document Release per ECO 214151 This document is an unpublished work Copyright 2014 Honeywell International Inc All rights This document and all information and expression contained herein are the property of Honeywell International Inc and is provided to the recipient in confidence on a need to know basis Your use of this document is strictly limited to a legitimate business purpose requiring the information contained therein Your use of this document constitutes acceptance of these terms ENGINEERING REFERENCE DOCUMENT Typed signatures constitute approval Actual CAD Prepared Drawing Using MSWord Software signatures on file at Honeywell in Redmond WA Not to be manually altered CONTRACT NO PRECIOUS METAL INDICATOR CODE Honeywell International Inc Honeywell NA Redmond WA 98073 9701 DRAWN McAnulty 03 04 2014 CHECK 03 04 2014 Software and Databases Media Loading ENGR B McAnulty 03 04 2014 Procedure for MKV A EGPWS QA SIZE CAGE CODE DWGNO REV APVD K Allen 03 04 2014 A 97896 PDS69000940 301 1 SHEET 10F17 REVISIONS CONT ALL SHEETS SAME REVISION STATUS PF DESCRIPTION
10. RINC 615A DATALOADER program 14 Click on Start then select Shutdown to turn off the 2000 15 Disconnect the Ethernet Cable from the DATA LOAD port on the MKV A 16 Perform the Software Verification per paragraph 5 3 CAGE CODE 97896 SCALE NONE SIZE A DWG PDA69000940 301 REV SHEET 10 HIF 1472R5 5 2 3 Installing Software Object Media Into Non Teledvne 2000 Data Loader Svstem NOTE Since there are many different ARINC 615A compatible Data Loader Systems commercially available it is not practical to try and provide all the different instructions needed to load MKV A Software Media into these units Therefore follow the manufactures instructions for the particular ARINC 615A compatible Data Loader System being used 5 2 3 1 This procedure assumes that the ARINC 615A compatible Data Loader System has been properly configured and has all required software installed per manufactures instructions 5 2 3 2 Obtain the CD ROM Disc with desired Software Object Media of Table 4 1 5 2 3 3 Following the ARINC 615A compatible Data Loader System manufactures instructions do the following 1 Energize and start the Data Loader System 2 Insert the CD ROM Disc with the Software Object Media into the Data Loader System CD ROM Drive 3 If not done so already create a directory for the Software Media and load the Software Media on the CD ROM Disc into that directory 4 Remove the CD ROM D
11. Select the MODEL and AIRPLANE TAIL NUMBER if necessary and applicable 12 Click NEXT The installation should complete at this point 13 Click on the Installation Complete dialog box 14 Click LOGOFF LOADSTAR and then CLOSE on the following screen CAGE CODE 97896 SCALE NONE SIZE A DWG NO PDA69000940 301 REV SHEET 13 HIF 1472R5 5 3 Software Media Installation Verification 5 3 1 A verification of the Software Media installation is done with the self test ST function The ST function cannot be started if the EGPWS does not identifv that the aircraft is on the ground 5 3 1 1 The operation and characteristics of the ST function are given below 1 The ST function can be started from the two possible locations e The aircraft cockpit with the EGPWS test switch NOTE Use of the cockpit ST function can be different from one aircraft to another For 9 example the ST function can be started when the GPWS PULL UP indicator is pushed or when a separate ST switch is pushed e The ST button behind the front panel door of the EGPWS The ST button is used to start the ST function from the aircraft cockpit or the EGPWS front panel The EGPWS ST function has six levels that identify the data given below e Condition and configuration of the EGPWS e Fault and Warning history e Condition of the different inputs To help go through the different levels there are two cancel functions e Short c
12. ancel push and hold the ST button for more than 0 5 second but less than 2 seconds e Long cancel push and hold the ST button more than 2 seconds but less than 8 seconds The short cancel and long cancel functions operate differently when the ST is in different levels To start the ST sequence or to continue from one level to another use the short cancel When the instruction push the ST button is given in this paragraph use the short cancel sequence The procedure given below moves the operator directly to the Level 3 ST system configuration Most of the Level 1 and Level 2 STs are not done Push and release the ST button to start the Level 1 ST After the Level 1 ST message starts push and hold the ST button for more than 0 5 second but less than 2 seconds short cancel This cancels the Level 1 ST and starts the Level 2 ST After the Level 2 ST CURRENT FAULTS message starts the Level 2 ST can be canceled by either a short cancel or long cancel For short cancel press and hold the ST button for more than 0 5 seconds but less than 2 seconds Press and release the ST button within 3 seconds of hearing the message PRESS TO CONTINUE This starts the Level 3 ST system configuration 10 Verify that the correct Application Software or Database version installed is heard 11 When the Level 3 ST is complete the message PRESS TO CONTINUE comes on If CAGE CODE HIF 1472R5 the ST button is not pushed within 3
13. ble Data Loader System 4 1 2 Aircraft Personality Database APD Special Information Table 4 1 lists the base Object Media part number to be used to create a unique customer APD number Reference document 2 1 3 SWM69000940 803 User Manual for the APD Tool of the MKV A Enhanced Ground Proximity Warning System gives the procedure for creating a unique APD The completed APD created will be loaded onto a USB Flash Drive then downloaded into the MKV A EGPWS 4 2 Application Software and Databases Media Base Part Numbers Table 4 1 Application Software and Databases Media Base Part Numbers Description Object Media USB Object Media Flash Drive ARINC 665A CD ROM Application Software HNR5B 1094 05XX pd Terrain Obstacle Runway DO69001801 05XX 1801 05 and Envelope Modulation Database SWM69900070 XXX N A Reloadable Customer Definitions RCD si Airplane Personalitv SWT69000940 5XX N A Database See paragraph 4 1 2 for instructions Note MKV A APD file is designed to be created by customers utilizing the Honeywell ADP tool As such the part number for the APD file will be customer unique The file will be copied to a USB flash drive for loading into the MKV A Refer to paragraph 4 1 2 for details CAGE CODE 97896 SCALE NONE SIZE A DWG PDA69000940 301 REV SHEET 6 HIF 1472R5 5 0 Software and Databases Loading Procedures For the following proc
14. edures the term Software Media refers to either MKV A Application Software or one of the Databases listed in Table 4 1 5 1 Loading Software and Databases on the Aircraft Using a USB Flash Drive 5 1 1 Obtain a USB Flash Drive with the Application Software or Database object media listed in Table 4 1 5 1 1 1 Refer to Figures 1 and 2 to do the work in this section 1 Make sure the circuit breaker is in and the power to the EGPWS is on 2 Open the door on the EGPWS front panel 3 Verify the LED status as follows DATALOAD STATUS LED is OFF COMPUTER STATUS LED is Green EXTERNAL FAULT LED is OFF could be Yellow if a required external signal is missing 4 Putthe USB Flash Drive with the Software Media into the USB DATA LOAD Port on the Front Panel of the MKV A EGPWS 5 The DATALOAD STATUS LED will sequence as follows during loading e LED will be Yellow during Application Code loading The MKV A will reboot DATALOAD STATUS LED will be Yellow after MKV A fully reboots e When finished the DATALOAD STATUS LED will be Green After the Software Media is finished loading remove the USB Flash Drive The MKV A will reboot After 25 seconds maximum the Computer Status LED should be illuminated Green 9 The EXTERNAL FAULT LED will be OFF could be Yellow if required external signal is missing 9339 10 Perform the Software Verification per paragraph 5 3 CAGE CODE 97896 SCALE NONE SIZE
15. en formatting these devices using the Windows Explorer Format utility if FAT32 is not an available selection then format the device by doing the following e Using Windows go to Start then select Run which will bring up a command line At the command line type format drive letter gt FS FAT32 where drive letter is the USB Flash Drive Click OK to begin formatting After completion of formatting the USB Flash Drive is now ready for use 3 2 CD ROM ARINC 615A Data Loader System Object Media Application Software and Terrain Database Software object media listed in Table 4 1 comes pre loaded on CD ROM and is used when loading software media into a ARINC 665A compatible Data Loader System then from the Data Loader System into the MKV A It is permissible to copy the contents of a CD ROM onto a different CD ROM CAGE CODE 97896 SCALE NONE SIZE A DWG PDA69000940 301 REV SHEET 5 HIF 1472R5 4 0 Application Software and Databases Media For the purposes of the following procedures the term Software Media will refer to either MKV A Application Software Terrain Database Reloadable Customer Definitions RCD Database or Aircraft Personality Database APD Table 4 1 shows the Software Object Media base part numbers and the type of media available for each 4 1 1 Application Software and Terrain Database software object media can be obtained pre loaded ROM for downloading onto an ARNIC 665A compati
16. es instructions energize and boot up the Data Loader System Navigate to the folder directory where the MKV A Software Media files are located Refer to paragraph 5 2 3 Following the manufactures instructions start the download of the Software Media into the MKV A EGPWS The MKV A Software Media should begin loading The DATALOAD STATUS LED at the Front Panel of the MKV A EGPWS will sequence as follows during loading DATALOAD STATUS LED will be Yellow during Application Code loading The MKV A will reboot The DATALOAD STATUS LED will be Yellow after MKV A fully reboots e When finished the DATALOAD STATUS LED will be Green After the Application Software is finished loading the MKV A will reboot 10 After 25 seconds maximum the COMPUTER STATUS LED should be illuminated Green 11 The EXTERNAL FAULT LED will be OFF could be Yellow if required external signal CAGE CODE HIF 1472R5 is missing 97896 SCALE NONE SIZE A DWG NO PDA69000940 301 REV SHEET 8 12 Application Software downloading is complete 13 Using manufactures instructions stop close the Data Loader program 14 Disconnect the Ethernet Cable from the DATA LOAD on the MKV A 15 Perform the Software Verification per paragraph 5 3 5 2 2 Loading Software Media using a Teledvne PMAT 2000 Data Loader Svstem NOTE This section gives an example of down loading the Software Media from a Teledvne 20
17. h 3 1 2 3 1 1 The USB Flash Drive must have ONLY ONE of the software object media versions loaded into the root directory at a time For example if the operator wishes to load both Application Software and the Terrain Database into the MKV A load one of these software media part numbers into the root directory of the Flash Drive Follow the procedure for loading software media into the MKV A using USB Flash Drive see paragraph 5 1 After loading is complete delete the Application Software from the root directory and load the Terrain Database in its place and repeat the downloading procedure CAGE CODE 97896 SCALE NONE SIZE A DWG PDA69000940 301 REV SHEET 4 HIF 1472R5 3 1 2 Copying USB Flash Drive Media Onto a Different USB Flash Drive It is permissible to copy the contents of a USB Flash Drive with pre installed MKV A Application Software part number SWM69000940 5XX into a different USB Flash Drive as long as the following instructions are observed MKV A supports FAT16 USB Flash Drive devices less than 2 Gbytes and FAT32 USB Flash Drive devices greater than 2 Gbytes Formatting USB Flash Drive as exFAT file also known as FAT64 files will make the device incompatible with the MKV A operating system USB Flash Drive that are less than 32 Gbytes in size may be formatted using Windows Explorer with no special instructions When formatting USB Flash Drive that are 32 Gbytes or greater precautions must be taken Wh
18. isc from the Data Loader System CD ROM Drive CAGE CODE 97896 SCALE NONE SIZE A DWG NO PDA69000940 301 REV SHEET 11 HIF 1472R5 5 2 4 Installing Software Media Into Teledyne 2000 Data Loader System NOTE This section gives an example of loading the HNR5E 1094 0504 Application Software into a Teledyne PMAT 2000 ARINC 615A Data Loader System The instructions found in this section are correct as of the date of the publication of this service bulletin but may be subject to change in the future due to software updates to the Data Loader System When following this procedure always refer to the manufactures instructions which take precedence over these instructions 5 2 4 1 Table 5 1 lists the Teledyne PMAT 2000 Data Loader System hardware and software used with the following instructions The items in the table are for reference only and are subject to change from the manufacture without notice When following this procedure always refer to the manufactures instructions which take precedence over these instructions Table 5 1 Teledyne PMAT 2000 Data Loader System Teledyne Controls Nomenclature CAGE PN 80000 05 PMAT 2000 1 98571 80030 4 Cable Assembly 1 98571 OBAWO 80079 1 Adaptor Cable PMAT 2000 to 1 98571 Ethernet 80719 2 PMAT 2000 80000 05 1 98571 Windows XP Standard SW With 615A and Loadstar SW Media PN 2238162 PMAT 2000 USB Boot Floppy 1 98571 01 SW PN 80385 1 SW