1. button had to be clicked in order to re load the value from the inverter and see the change Now registers modified via the monitor tab are auto refreshed immediately after being written down to the inverter o Fixed a bug whereby failed XML sockets were not being properly recycled This could lead to a web browser session being unable to establish a successful XML socket connection until the interface card is rebooted o Fixed a bug which prevented the SMTP authentication from being deleted once settings have been entered User s manual version e 10653 2 210 000 gt 02 17 2009 Multiprotocol firmware e 2 200 release e EtherNet IP changes o Added the ability to directly access non scanned inverter configuration parameters e Allen Bradley CSP PCCC AB Ethernet changes o Added the ability to directly access non scanned inverter configuration parameters e BACnet IP changes o Added support for Reinitialize Device service e Modbus TCP changes o Added the ability to directly access non scanned inverter configuration parameters o Added optional supervisory timer Page 5 of 8 ce 1600 Aspen Commons Suite 210 Middleton WI 53562 Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com e Web page changes o Added non scanned parameters parameter groups and non scanned parameter refresh button to monitor tab o Added supervisory timer selection to Modb
2. 000 04 14 2009 Multiprotocol firmware V2 210 release Page 4 of 8 ce 1600 Aspen Commons Suite 210 Middleton WI 53562 Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com e Modbus TCP changes o Corrected a bug which resulted in corruption of the last half of the response data to a read request targeting non scanned registers e BACnet IP changes o Fixed an issue whereby the priority array entries for user added objects i e BACnet objects that are added by direct XML file editing were not being properly initialized e Web page changes o Modified the behavior of non scanned register values when they are modified via the monitor tab Previously the refresh button had to be clicked in order to re load the value from the inverter and see the change Now registers modified via the monitor tab are auto refreshed immediately after being written down to the inverter o Fixed a bug whereby failed XML sockets were not being properly recycled This could lead to a web browser session being unable to establish a successful XML socket connection until the interface card is rebooted o Fixed a bug which prevented the SMTP authentication from being deleted once settings have been entered PROFINET firmware e V2 210 release e Web page changes o Modified the behavior of non scanned register values when they are modified via the monitor tab Previously the refresh
3. and 04 Add support for Allen Bradley CSP protocol for Allen Bradley PLC 5 and SLC 500 series PLCs PROFINET firmware V2 000 release Add Alarm monitoring functionality with email reporting Add ability to change authentication information config tab Add ability to change IP address assignments via web page config tab User s manual version 10653 2 000 000 gt 10 09 2007 Multiprotocol firmware V1 000 initial release PROFINET firmware V1 000 initial release User s manual version 10653 1 000 000 Page 8 of 8
4. changes o Added Run Idle Flag behavior checkbox to EtherNet IP tab o Added SMTP Authentication fields to Alarm tab e Other changes Page 6 of 8 1600 Aspen Commons Suite 210 Middleton WI 53562 gt Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com o Added support for email servers that require authentication SMTP AUTH when sending alarm emails PROFINET firmware e No new PROFINET firmware released at this time current version remains at V2 000 User s manual version e 10653 2 110 000 07 25 2008 Multiprotocol firmware e 2 100 release e Modbus TCP changes o Fixed infinite looping that could occur if extraneous data remains in receive buffer as a result of an improperly coded Modbus master driver sending extra garbage bytes after the normal data packet Added register remapping capabilities ref section 5 10 2 Socket timeout resolution entered via web page Config tab increased to 0 01s increments e BACnet IP changes o Added support for output object priority arrays and relinquish default properties o Changed added supported datatypes for reading and writing object properties ref Datatypes Supported table in section 8 4 1 e EtherNet IP changes o Allow only one exclusive owner connection o Allow only one input connection instance to be active at a time e g 70 71 or 150 o Allow multiple clients to simultaneously establish i
5. atibility e CSP changes o Added logical ASCII addressing for both Typed Read and Typed Write commands Page 1 of 8 IEC 1600 Aspen Commons Suite 210 Middleton WI 53562 1 Z Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com PROFINET firmware e V2 330 release e CRITICAL FIRMWARE UPDATE NOTE Review the V2 300 firmware release notes before updating to this firmware version e Increased response time to accommodate large register requests User s manual version e No new user s manual released at this time current version remains 10653 2 320 001 gt 08 14 2013 Multiprotocol firmware e No new firmware released at this time current multiprotocol firmware is still V2 320 PROFINET firmware e V2 321 release e CRITICAL FIRMWARE UPDATE NOTE Review the V2 300 firmware release notes before updating to this firmware version e Modified the FTP server to improve Windows Explorer FTP compatibility e PROFINET changes o Modified the handling of modules after the PROFINET connection is terminated The modification will improve the compatibility with the PROFINET controller on the subsequent connection User s manual version e No new user s manual released at this time current version remains 10653 2 320 001 gt 04 29 2013 Multiprotocol firmware e No new firmware released at this time current multiprotocol firmware is still V2 320 PROFINET
6. ce 1600 Aspen Commons Suite 210 Middleton WI 53562 1 A Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com FR A7N ETH Version Info gt 07 21 2015 Multiprotocol firmware e V2 333 release e EtherNet IP changes o Ignore socket address info items to improve the connection establishment o Fixed get attribute single of AC DC assembly I O data e Modbus TCP changes o Added option to enable and disable the connection timeout timer e BACnet IP changes o Internal memory improvements e Web page changes o Changed XML TCP port to 843 to improve firewall and internetwork compatibility Profinet firmware e V2 333 release e PROFINET changes o Updated PROFIdrive profile state machine transitions e Web page changes o Changed XML TCP port to 843 to improve firewall and internetwork compatibility GSDML file e GSDML V2 0 ICC FR_A7N_ETH 20150210 xml e Limited the lowest I O cycle update time to 8ms e Updated the maximum input output and total sizes to account for overhead data User s manual version e 10653 2 333 000 gt 10 17 2014 Multiprotocol firmware e V2 330 release e CRITICAL FIRMWARE UPDATE NOTE Review the V2 300 firmware release notes before updating to this firmware version e Increased response time to accommodate large register requests e Improved handling and recycling of network resources e Modified the FTP server to improve Windows Explorer FTP comp
7. d Mitsubishi MELSEC server support BACnet IP changes o Fixed invalid character set for Device Object character string properties EtherNet IP changes o Fixed ListServices to correctly return the service string Web page changes o Added MELSEC tab PROFINET firmware V2 300 release CRITICAL FIRMWARE UPDATE NOTE Migrating to V2 300 or later versions of the PROFINET firmware from a previous version requires an additional intermediate step not typically necessary with version to version firmware updates Prior to uploading the V2 300 or later PROFINET image with filename 10640a pnio vXXXX image bin you must first upload and run the associated V2 300 multiprotocol image with filename 10640a_rom bin The reason for this is because V2 300 amp future firmware releases require a one time adjustment to internal memory locations and this adjustment code only exists in the multiprotocol 10640a_rom bin firmware image After applying the V2 300 multiprotocol image and allowing the card to reboot you may then freely apply the V2 300 or later PROFINET image to return PROFINET functionality to the interface card No interface card configuration information is modified or lost during this stair step application process If you have any questions regarding this update process please contact ICC technical support for assistance Fixed PROF Idrive RPM output conversion bug Add support for timeout processing User s manual version 10653 2 300
8. e V2 300 firmware release notes before updating to this firmware version e EtherNet IP changes o Added class 1 I O support for point to point unicast in the TO direction PROFINET firmware e No new PROFINET firmware released at this time current version remains V2 300 EtherNet IP EDS file e V2 1 e Updated connection description to support point to point unicast in the TO direction User s manual version e 10653 2 310 000 Page 3 of 8 1600 Aspen Commons Suite 210 Middleton WI 53562 Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com gt 02 01 2011 Multiprotocol firmware V2 300 release CRITICAL FIRMWARE UPDATE NOTE Note that the V2 300 multiprotocol firmware image name 10640a_rom bin does not follow the firmware image filename conventions used with previous firmware updates typically something like 10640a_eth vXXXX_image bin This name change for V2 300 is intentional do not modify the filename prior to uploading it to the interface card The reason for this is because V2 300 amp future firmware releases require a one time adjustment to internal memory locations and the adjustment code contained in this firmware release will only be executed by the interface card when it receives this firmware file with the special filename 10640a_rom bin If you have any questions regarding this update process please contact ICC technical support for assistance Ad
9. firmware e No new firmware released at this time current PROFINET firmware is still V2 310 User s manual version e 10653 2 320 001 principle documentation update related to E700 installation and setup gt 08 30 2011 Multiprotocol firmware e No new firmware released at this time current multiprotocol firmware is still V2 320 Page 2 of 8 IEC 1600 Aspen Commons Suite 210 Middleton WI 53562 1 ZA A Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com PROFINET firmware e No new firmware released at this time current PROFINET firmware is still V2 310 User s manual version e 10653 2 320 000 principle documentation update related to RSLogix 5000 Add On Instructions only gt 05 25 2011 Multiprotocol firmware e V2 320 release e CRITICAL FIRMWARE UPDATE NOTE Review the V2 300 firmware release notes before updating to this firmware version e Fixed error code blinking pattern rate PROFINET firmware e V2 310 release e CRITICAL FIRMWARE UPDATE NOTE Review the V2 300 firmware release notes before updating to this firmware version e Fixed error code blinking pattern rate e Profinet changes o Added support for timeout processing User s manual version e No new user s manual released at this time current version remains 10653 2 31 0 000 gt 05 01 2011 Multiprotocol firmware e V2 310 release e CRITICAL FIRMWARE UPDATE NOTE Review th
10. nput only connections O Added support for the ODVA AC DC drive profile instances 20 amp 70 21 amp 71 ref section 8 2 2 o Added support for the AC DC Drive Control Supervisor and Motor Data objects o Changed product type code from Communications Adapter 12 to AC Drive 2 e Web page changes o Added Modbus tab o Corrected an issue caused by a new Flash Player policy file request that occurs with the latest release of the Flash Player browser plug in This would cause the XML sockets to fail on their initial connection attempt PROFINET firmware e No new PROFINET firmware released at this time current version remains at V2 000 User s manual version e 10653 2 100 000 Page 7 of 8 1600 Aspen Commons Suite 210 Middleton WI 53562 Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com gt 04 14 2008 Multiprotocol firmware V2 000 release Add Alarm monitoring functionality with email reporting Add ability to change authentication information config tab Add ability to change IP address assignments via web page config tab Add Ethernet IP class 1 IO messaging support with associated consumed produced data configuration Ethernet IP class 3 explicit messaging tag references expanded to allow direct access to any available register Ethernet IP now triggers timeout processing when connection errors occur Add support for Modbus TCP function codes 02
11. us tab o Added Dashboard tab PROFINET firmware e 2 200 release e PROFINET changes o Added acyclic access to non scanned inverter configuration parameters o Added support for PROFIdrive profile e Web page changes o Added non scanned parameters parameter groups and non scanned parameter refresh button to monitor tab Added Dashboard tab Corrected an issue caused by a new Flash Player policy file request that occurs with the latest release of the Flash Player browser plug in This would cause the XML sockets to fail on their initial connection attempt o Added SMTP Authentication fields to Alarm tab e Other changes o Added support for email servers that require authentication SMTP AUTH when sending alarm emails User s manual version e 10653 2 200 000 gt 08 21 2008 Multiprotocol firmware e V2 110 release e EtherNet IP changes o Corrected a bug introduced in V2 100 firmware that caused the user configured timeout action s to not execute when an EtherNet IP connection timeout occurred o Added the ability for the user to choose the action to take when an I O connection s run idle header indicates that the client is in the idle state ref section 5 8 3 e Modbus TCP changes o Increased the number of registers writable in a write multiple registers packet from 100 to 123 o Increased the number of coils writable in a force multiple coils packet from 1600 to 1968 e Web page

Download Pdf Manuals

image

Related Search

Related Contents

Easysphere  Kenmore Elite 30'' Double-Oven Slide-In Electric Range w/ Convection - Black Installation Guide  MANUEL D`UTILISATION  Bloodborne Pathogen Compliance Tool User Manual for Site  condiciones generales de prestación del servicio telefónico móvil de  PCRキット 取扱説明書ver1.0  全ページpdf (4.71MB)  Publications de Claire Piguet  Orved Eco Vacuum.pm6  UNIDAD DIDACTICA OPERADOR DE ANDAMIOS  