Home
QUICK START GUIDE - U-Line
Contents
1. NOTICE Route the water supply line through the unit so it does not come into contact with any internal components other than the solenoid valve Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line QUICK START GUIDE U LINE u line com 4 On the back panel break away filler feature in bushing with flat screwdriver Remove with flat screwdriver 5 Thread water line through back panel hole with bushing o 6 Turn on water supply and check for leaks 7 Reinstall back panel and grille front access panel 8 Install retaining clip Drain Model numbers including 00 or 07 do not include a factory installed drain pump Model numbers including 40 or 47 include a factory installed drain pump DRAIN CONNECTION If your U Line unit did not come with a factory installed drain pump you must use a gravity style drain connection For assistance in determining if your unit has a pump please contact U Line The floor drain must be large enough to accommodate drainage from all attached drains Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and or potentially flowing onto the floor which may result in personal injury or property damage NOTICE Drain
2. Continue to pull gasket free from gasket channel 4 Upon removal lay gasket down on a flat surface 5 The panel should be aligned with the outside edge opposite the hinge and high enough to align with the highest point in the door drawer Align Top Of Panel With Highest Point Of Door Drawer Align Panel Against Door Drawer Edge First NOTICE Due to differences in floor construction or surrounding cabinetry the panel may not sit flush with the top of the door drawer om 6 Secure integrated Eai panel to door drawer Clamp using clamps A robust tape may also be used U Line recommends the use of bar clamps to secure the panel to the door drawer If Wood Panel Panel y Door Drawer using tape be certain the tape will not damage panel finish upon removal 7 penis ERRADAS o do drill bit drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door drawer frame as a guide NOTICE It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed 8 Locate 6 of the 6x 1 1 4 32 mm screws provided with your unit QUICK START GUIDE U LINE u line com 9 Using a Phillips screwdriver place one screw into each of the 6 pilot holes and screw down Do not overtighten Screws 10 Be sure the screws force the
3. can NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all connections and fittings are free from leaks QUICK START GUIDE U LINE u line com GRAVITY DRAIN With Trap Poor Drainage Water Will Back Up With Trap and Vent Proper Drain A gravity drain may be used if Drain line has at least a 1 drop per 48 approximately 2 cm drop per 100 cm of run Drain line does not create traps and is vented per local code 1 Cut the pre installed drain tube to length 2 Connect to your local plumbing per the local code 3 If necessary insulate drain line to prevent condensation Failure to connect water supply or drain line connections properly can result in personal injury and property damage Gravity drain connections must be routed downward from the rest of the unit at the rate of 1 4 per foot 1 cm per 50 cm FACTORY INSTALLED DRAIN PUMP If your drain line will run up to a stand pipe disposal or spigot assembly or does not otherwise meet the requirements for a gravity drain you may have ordered a pre installed U Line P60 drain pump If you need to install a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical installations requiring a drain pump Stand Pipe P60
4. during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line When plugged in the unit will begin operating under the factory default settings If the unit was turned off during installation simply press and the unit will immediately switch on To turn the unit off press and hold for 5 seconds and release Ice ICE CUBE THICKNESS ADJUSTMENT Interval As Required NOTICE Ice thickness adjustment should only be made one increment at a time Allow ice maker production to stabilize for 24 hours before rechecking ice thickness The ice cube thickness is factory set for best overall performance The factory setting is designed to maintain an ice bridge of approximately 1 16 to 1 8 1 6 mm to 3 2 mm under normal conditions resulting in a dimple of approximately 1 4 to 1 2 6 4 mm to 12 7 mm in 11 QUICK START GUIDE U LINE u line com depth A fuller cube with less of a dimple results in a Ice thickness adjustments are made using the control thicker ice bridge As the ice bridge becomes thicker the panel as follows tendency for the cubes to stay together as a slab increases A bridge thicker than 1 8 3 2 mm may cause 1 To enter the thickness adjustment mode cubes to overfill the ice bucket e Press and hold B for 5 seconds e The display will switch to 0 to confirm the DIMPLES thickness adjustment mode has been selected The factory set
5. style drain or factory installed drain pump Products without a drain pump may only use a gravity style drain Failure to connect water supply or drain line connections properly may result in water leakage personal injury and or property damage Disconnect power and turn off water to the unit before attempting to alter these connections These connections are the responsibility of the owner and must be connected per local plumbing code If you are uncertain of how to safely and properly install this product contact a licensed plumber Water Supply Connection Review obey and understand the local plumbing codes before you install your unit Connect to the cold water supply The water pressure should be between 20 and 120 psi 138 and 827 kPa The water line MUST have a shut off valve on the supply line QUICK START GUIDE U LINE u line com Do not use any plastic water supply line The line is under pressure at all times Plastic may crack or rupture with age and cause damage to your home Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket The gasket provides an adequate seal other materials could cause blockage of the valve Failure to follow recommendations and instructions may result in damage and or harm flooding or void the product warranty Turn off water supply and disconnect electrical supply to unit prior to installation 1 Turn of
6. INE u line com Electrical SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting or removing power cord removing power plug or direct wiring can cause serious injury fire loss of property and or life and will void the warranty Never use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended A GFCI ground fault circuit interrupter is usually not required for fixed location appliances and is not recommended for your unit because it could be prone to nuisance tripping However be sure to consult your local codes Water Hookup INDOOR MODELS PREPARE PLUMBING Please use the braided stainless steel water supply line which comes attached The water line is fitted with a standard 1 4 6 35 mm compression fitting Prior to installation determine if this product contains a gravity
7. Line warrants each U Line product to be free from defects in materials and workmanship for a period of one year two years on Modular 3000 Series from the date of purchase U Line further warrants the sealed system consisting of the compressor condenser evaporator hot gas bypass valve dryer and connecting tube in each U Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase During the initial one year warranty period two years on Modular 3000 Series for all U Line products U Line shall 1 repair any product or replace any part of a product and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall be responsible for the labor costs performed by a U Line authorized service company incurred in connection with the replacement of any defective part During years two through five of the warranty period for the sealed system U Line shall 1 at U Line s option repair or replace any part of the sealed system and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall be responsible for the labor costs incurred in connection with the replacement of any defective part of the sealed system All other charges including transportation charges for replacements under this warranty an
8. PLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ALL OF WHICH ARE DISCLAIMED U Line s sole liability and your exclusive remedy under this warranty is set forth in the paragraphs above U Line shall have no liability whatsoever for any incidental consequential or special damages arising from the sale use or nstallation of the product or from any other cause whatsoever whether based on warranty express or mplied or otherwise based on contract tort or any other theory of liability Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state 6 U Line s Outdoor Limited Warranty set forth in this Paragraph 6 shall apply to U Line models deemed suitable for outdoor use by Underwriters Laboratory UL as noted in the U Line Product Catalog U Line s website and or on the serial tag located inside the product Warranty 6 2014 Rev G A Outdoor product may come into contact with rain by virtue of outdoor use Exposure to other sources of Copyright 2014 U Line Corporation All Rights Reserved Publication Number 30421 7 2015 Rev B 14
9. Pump Required gt Joe Waste Shut Off Valve lt Cold Water Waste Disposal Assembly P60 Pump Required Air Gap Optional Hook Up f A iy 1 f I i l Waste li gt li i t li Cold A Hot Water 4 Water Shut Off Valve QUICK START GUIDE O v Line u line com Y Branch Tailpiece P60 Pump Required Air Gap Optional Hook Up 7 23 gt waste Shut Off Valve lt Cold 3 Hot Water non Water NOTICE The maximum lift for the P60 drain pump is 10 feet This must be done as close to the rear of the unit as possible Door Swing Wall M wall 1 4 Min 2 1 8 Min 6 mm gt lt 54 mm lt 90 90 Door Swing Door Swing Ww Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance if installed next to a wall Allow for additional space for any knobs or pulls installed on the integrated panel frame General Installation LEVELING INFORMATION 1 Use a level to confirm the unit is l
10. QUICK START GUIDE 1000 Series e CLR1215 115 V 60 Hz QUICK START GUIDE U LINE u line com WELCOME TO U LINE f Congratulations on your U Line purchase Your product comes from a company with over five decades and three generations of premium modular ice making refrigeration and wine preservation experience U Line continues to be the American leader delivering versatility and flexibility for multiple applications including residential light commercial outdoor and marine use U Line s complete product collection includes modular Wine Captain Models Beverage Centers Clear Ice Machines Crescent Ice Makers Glass amp Solid Door Refrigerators Drawer Models Freezers and Combo Models U Line has captivated those with an appreciation for the finer things with exceptional functionality style inspired innovations and attention to even the smallest details We are Known and respected for our unwavering dedication to product design quality and selection U Line is headquartered in Milwaukee Wisconsin with a west coast office located in Laguna Beach California and European support in Dublin Ireland U Line has shipped product to five continents for over two decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all availab
11. U Line products are designed to operate in ambient temperatures between 50 F and 100 F unless otherwise noted in the product manual Exposure to temperatures outside this range may cause degradation of performance and issues such as lower ice production or spoiled contents that are not covered under the terms of this warranty as a result of that exposure U Line product may not be subjected to temperatures below 40 F without following the winterization and vacation shutdown procedures in the user guide water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than 1 8 deep in water hurricanes splashing of pool water or directing a spray from a hose or similar device into and around the unit If a product defect is discovered during the applicable warranty period you must promptly notify either U Line at 8900 N 55th Street Milwaukee Wisconsin 53223 USA or at 1 800 779 2547 or the dealer from whom you purchased the product In no event shall such notification be received later than 30 days after the expiration of the applicable warranty period U Line may require that defective parts be returned at your expense to U Line s factory in Milwaukee Wisconsin for inspection Any action by you for breach of warranty must be commenced within one year after the applicable warranty period THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IM
12. d labor costs not specifically covered by this warranty shall be the responsibility of the purchaser This warranty extends only to the original purchaser of the U Line product The Product Registration Card included with the product should be promptly completed by you and mailed back to U Line or you can register on line at www u lineservice com 13 QUICK START GUIDE U LINE u line com The warranty listed above does not apply to floor display models The warranty for these models shall be 30 days from the date of retail purchase and only if U Line s Product Registration Card included with the unit is completed and mailed back or electronically submitted to U Line This 30 day warranty does not apply to cosmetic damages A proof of purchase may be required The following conditions are excluded from this limited warranty use of cleaners other than the recommended stainless steel cleaners and U Line Clear Ice Maker cleaner installation charges damages caused by disasters or acts of God such as fire floods wind and lightning damages incurred or resulting from shipping improper installation unauthorized modification or misuse abuse of the product customer education calls food loss and spoilage door and water level adjustments except during the first 30 days from the date of installation defrosting the product adjusting the controls door reversal and cleaning the condenser
13. evel Level should be placed along top edge and side edge as shown Sd S lt 2 Ifthe unitis not level adjust the legs on the corners of the unit as necessary PEEPEECIIIIT Ea Turn to Adjust 3 Confirm the unit is level after each adjustment and repeat the previous steps until the unit is level INSTALLATION TIP If the room floor is higher than the floor in the cutout opening adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is correctly positioned in the opening QUICK START GUIDE U LINE u line com INSTALLATION 1 Plug in the power electrical cord 2 Gently push the unit into position Be careful not to entangle the cord or water and drain lines 3 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 3 mm below the countertop 4 Install the anti tip bracket 5 Remove interior packing material and wipe out the inside of the unit with a clean water dampened cloth Integrated Panel Installation 1 Fully open door drawer gt 2 Starting at corner pull gasket away from door drawer 3
14. f water supply and disconnect electrical supply to product prior to attempting installation 2 Locate the desired cold water supply location 3 Locate braided stainless steel water supply line and connect to your cold water supply The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing However make certain that the tubing is not pinched or damaged during installation 4 Turn on water and check for leaks 5 Route water supply line in cable clamp and secure with screw OUTDOOR MODELS PREPARE PLUMBING The water valve uses a standard 1 4 6 35 mm compression fitting U Line recommends using accessory water hook up kit part WATERHOOKUP The kit includes a 10 3 m braided flexible water supply line and a brass hose fitting When using a 1 4 6 35 mm O D soft copper supply line use the brass nut and sleeve included with the unit QUICK START GUIDE U LINE u line com Prior to installation determine if this product contains a gravity style drain or factory installed drain pump Products without a drain pump may only use a gravity style drain Failure to connect water supply or drain line connections properly may result in water leakage personal injury and or property damage Disconnect power and turn off water to the unit before attempting
15. ir way past the opening on the gasket channel and sit flush against the bottom of the channel Integrated Panel Integrated Panel 11 Remove clamps from door drawer NOTICE If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten screws upon completion 12 Starting at the corners re install the gasket into the gasket channel in the frame Make sure the gasket is fully seated This may take some force 10 QUICK START GUIDE U LINE u line com Control Operation Up Down Alert Light Power Clean LED re avert CONTROL FUNCTION GUIDE View temperature in unit Press S and 5 together and release Toggle between F C Hold Banafe for five seconds FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Adjust ice thickness See Ice section The display will flash and then toggle from set point to temperature in unit The display will beep and display unit temperature Sabbath Mode See Sabbath Mode section Silent Mode ice production suspended for Hold 5 and 3 hours Clean Mode Hold for five seconds Display will show OFf First Use All U Line controls are preset at the factory Initial startup requires no adjustments NOTICE U Line recommends discarding the ice produced
16. lation ntegrated Panel Installation trol Operation 11 ce 13 Sab 11 First Use bath Mode 13 Warranty QUICK START GUIDE U LINE u line com Model List This guide provides the basics to get you started Looking for more information Visit u line com to view detailed User Guides for all U Line products Clear Ice U CLR1215S 00A U CLR1215S 40A U CLR1215INT 00A U CLR1215INT 40A U CLR1215B 00A U CLR1215B 40A U CLR1215W 00A U CLR1215W 40A Outdoor Series U CLR1212SOD 00A U CLR1212SOD 40A Visit http www u line com product literature userguides or scan this QR code to view all user guides online QUICK START GUIDE U LINE u line com Safety and Warning NOTICE Please read all instructions before installing operating or servicing the appliance Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type A DANGER Danger means that failure to follow this safety statement will result in severe personal injury or death Warning means that failure to follow this safety statement could result in serious personal injury or death Caution means that failure to follow this safety statement may result in minor or moderate personal injury proper
17. le for reference and download at u line com under Documentation PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Line product please take the following steps 1 U Line Customer Care must be contacted immediately at 1 800 779 2547 2 Service or repairs performed on the unit without prior written approval from U Line is not permitted If the unit has been altered or repaired in the field without prior written approval from U Line claims will not be eligible SERVICE INFORMATION Answers to Customer Frequently Asked Questions are available at u line com under Customer Care or you may contact our Customer Care group directly contact information below GENERAL INQUIRIES SERVICE amp PARTS ASSISTANCE U Line Corporation Monday Friday 8 00 am to 5 30 pm CST 8900 N 55th Street T 1 800 779 2547 ilwaukee Wisconsin 53223 USA F 1 414 354 5696 onday Friday 8 00 am to 4 30 pm CST Service Email onlineservice u line com T 1 414 354 0300 Parts Email onlineparts u line com F 1 414 354 7905 Email sales u line com u line com CONNECT WITH US f wW D Q Tubo in S Pg blog Designed engineered and assembled in WI USA QUICK START GUIDE U LINE u line com Contents Env Gen O o oo DW WN N e 11 Con Drai odel List Safety and Warning ironmental Requirements Electrical Water Hookup n Door Swing eral Instal
18. ting is 0 and the total range of adjustment is 5 to 5 ideal range is 1 to 1 Use El to raise the setting and thicken the ice bridge or to lower the setting to thin the ice bridge ICE BRIDGE Ice Bridge and Dimples Ice cubes in any given batch will vary so it is necessary to choose cubes from the sample area for comparison when making adjustments Cube Types 1 4 TO 1 2 1 16 TO 1 8 6 4 mm to 12 7 mm 1 6 mm to 3 2 mm DIMPLE ICE BRIDGE THIN BRIDGE THICK BRIDGE LITTLE OR DEEP DIMPLE NO DIMPLE _ l LJ 12 QUICK START GUIDE U LINE u line com Sabbath Mode 1 2 3 4 5 6 fF F F uuNne X B4 near Up Select Sol He U LINE E JB Down U Line Clear Ice Machine models are Star K certified and can be used during the Sabbath View a full list of Star K certified U Line units at www star k org To prepare the unit for the Sabbath 1 Press 3 and hold the until the unit turns off 2 No new ice will form when the unit is off but previously made ice will still be accessible present for over 24 hours Pump equipped models will continue to remove water as needed even if the unit is off Sabbath Mode remains active until is pressed again and the unit turns on Warranty U LINE CORPORATION LIMITED WARRANTY 1 U Line Corporation U
19. to alter these connections These connections are the responsibility of the owner and must be connected per local plumbing code If you are uncertain of how to safely and properly install this product contact a licensed plumber Water Supply Connection Connect to potable water supply only Review obey and understand the local plumbing codes before you install your unit Connect to the cold water supply The water pressure should be between 20 and 120 psi 138 and 827 kPa The water line MUST have a shut off valve on the supply line Do not use any plastic water supply line The line is under pressure at all times Plastic may crack or rupture with age and cause damage to your home Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket The gasket provides an adequate seal other materials could cause blockage of the valve Failure to follow recommendations and instructions may result in damage and or harm flooding or void the product warranty Turn off water supply and disconnect electrical supply to unit prior to installation Use caution when handling back panel The edges could be sharp 1 Turn off water supply and disconnect electrical supply to product prior to attempting installation 2 Remove the grille access panel in the front and the back panel 3 Locate water valve in the front of the unit and thread water supply line through
20. ty or equipment damage Environmental Requirements 115 V UNITS This model is intended for indoor interior applications only and is not to be used in installations that are open exposed to natural elements This unit is designed to operate between 50 F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is considered normal The condensation will evaporate when the humidity drops Damages caused by ambient temperatures of 40 F 4 C or below are not covered by the warranty OUTDOOR UNITS This unit is designed to operate between 50 F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is considered normal The condensation will evaporate when the humidity drops Damages caused by ambient temperatures of 40 F 4 C or below are not covered by the warranty QUICK START GUIDE U L