Home

File

image

Contents

1. Cross Jitter pk pk RMS Eye Width Width Width Burst Width Duty Cycle Duty Cycle Duty Cycle Distortion Delay Phase Area Measurements Area Cycle Area Cursors Dot vertical bar and horizontal bar cursors Waveform Processing Communications Signal Analyzer Up to eight math waveforms can be defined and displayed using the following math functions Add Subtract Multiply Divide Average Differentiate Exponentiate Integrate Natural Log Log Magnitude Min Max Square Root and Filter In addition measurement values can be utilized as scalars in math waveform definitions Mask Testing In addition to user defined masks the following predefined masks are built in gt CSA8000B Power Hequirements Line Voltage and Frequency 100 to 240 VAC 10 50 60 Hz 115 VAC 10 400 Hz Environmental Temperature Operating 10 C to 40 C Nonoperating 22 C to 60 C Relative Humidity Operating Floppy disk and CD ROM not installed 20 to 80 at or below 40 C upper limit derates to 45 relative humidity at 40 C Nonoperating 5 to 90 at or below 60 C upper limit de rates to 20 relative humidity at 60 C Standard Rate Gb s unless otherwise noted Altitude E Operating 3 048 m 10 000 ft SLUG tal Nonoperating 12 190 m 40 000
2. Bandwidth 20 GHz TDR Step Amplitude 250 mV polarity of either step may be inverted TDR System Reflected Rise Time lt 35 ps each polarity TDR System Incident Rise Time 28 ps typical TDR Step Maximum Repetition Rate 200 kHz TDR System Step 3 or less over the zone 10 ns to 20 ps before step transition Response Aberrations 10 5 or less typical for the first 400 ps following step transition 3 or less over the zone 400 ps to 5 ns following step transition 1 or less after 5 ns following step transition Values shown are warranted unless printed in an italic typeface which represents a non warranted characteristic value that the instrument will typically perform to 10 Optical Signal Analysis www tektronix com optical gt Ordering Information CSA8000B Communications Signal Analyzer Includes User manual quick reference card MS Windows 2000 compatible keyboard MS Windows 2000 compatible mouse touch Screen stylus online help programmer online guide power cord With OpenChoice software Tektronix provides enhanced test and measurement analysis with the capability of full integration of third party software on the Open Windows oscilloscopes By working with the industry leaders National Instruments and The MathWorks examples of software programs from these companies are featured on all Tektronix Open Windows oscilloscopes CSASOOOB Options Option C3 Three years of Calibration Service Optio
3. from 9 8 to 12 6 Gb s 80C12 Multi rate Datacom amp Telecom Optical Sampling Module The 80C012 module is a broad wavelength 700 to 1650 nm multi rate optical sampling module pro viding multi rate telecom and datacom test ing This highly flexible module can be con figured to support either lower data rate applications 1 to 4 Gb s or a wide variety of 10Gb s applications The low data rate applications include 1 2 and 4 Gb s FibreChannel and by 4 wavelength divi sion multiplex standards such as 10GBase X4 and 4 Lane 10 Gb s FibreChannel The sup ported 10Gb s application includes both datacom and telecom application The sup ported 10Gb s datacom applications include 10GbE applications at 9 953 10 3125 11 0957 Gb s and 10G FibreChannel appli cations at 10 51875 Gb s The 80C12 also provides telecom rate testing at 9 953 10 664 and 10 709 Gb s With its amplified O E converter design this module provides excellent signal to noise performance and high optical sensitivity allowing users to examine low power level optical signals Clock recovery for the 80C12 is provided via the 80A05 sold separately 8000 Series Sampling Oscilloscope Electrical Modules 80E01 Sampling Module The 80E01 is a single channel 50 GHz bandwidth sam pling module The 80E01 has a measured bandwidth of 50 GHz or more and a calcu lated rise time of 7 0 ps or less Displayed noise is typically 1 8 MVpys The front panel 4
4. kg Ib Width Height Depth Net 80E01 79 3 1 25 1 0 135 5 3 0 4 0 87 80E02 79 3 1 25 1 0 135 5 3 0 4 0 87 80E03 79 3 1 25 1 0 135 5 3 0 4 0 87 80E04 79 3 1 25 1 0 135 5 3 0 4 0 87 80E06 79 3 1 25 1 0 135 5 3 0 4 0 87 gt Electrical Sampling Module Characteristics ON Refer to Electrical Sampling Module User Manual for more detailed information Application Type Channels Input Impedance Channel Input Bandwidth Connector 80E01 Microwave 1 50 0 5 Q 2 4 mm female Precision 50 GHz General Purpose adapter to 2 92 mm included with 50 lt SMA termination 80E02 Low level Signals 2 50 0 5 Q 3 5 mm female 12 5 GHz 80E03 Device Characterization 2 50 0 5 3 5 mm female 20 GHz 80E04 TDR Impedance Characterization 2 50 0 5 Q 3 5 mm female 20 GHz with single ended common differential TDR capability 80E06 High speed Electrical 1 50 0 5 Q 1 85 mm female Precision 70 GHz Device Characterization adapter to 2 92 mm included with 50 Q SMA termination Values shown are warranted unless printed an italic typeface which represents non warranted characteristic value that the instrument will typically perform to Rise time is calculated from the formula Rise time 0 35 Bandwidth bandwidth is calculated from the formula Bandwidth 0 35 Rise time gt Electrical Sampling Module Characteristics continued Rise Time Maximum Input Vertical Number 10 to 90 Dynamic Range Offset Range Voltage of Digitized Bits 80 01 7 ps 1 0V 1 6V
5. tions interfaces such as GPIB Parallel Printer Port RS 232 C and USB Serial Ports and an Ethernet LAN connection In addition the platform includes several mass storage devices floppy disk remov able hard drive and CD ROM Gated triggering a feature that allows the exclu sion of selected time periods from being measured is offered as an option Finally because the system supports an Open Windows environment new levels of data analysis can be done directly on the instrument using commercially available software packages Communications Signal Analyzer gt CSA8000B Additionally TekVISA a standard software accessory allows the instrument to be placed under the control of software appli cations 0 LabView LabWindows Visual Basic Microsoft Excel C etc running on the instrument or on external PC worksta tions network connected to the instrument without the need for a GPIB hardware inter face Plug and play drivers for LabView and other programs are also supplied 8000 Series Sampling Oscilloscope Optical Modules 80C01 Multi rate Telecom Sampling Module The 80C01 module supports waveform conformance testing of long wavelength 1100 to 1650 nm signals at 622 2488 Mb s and 9 953 Gb s as well as general purpose testing with up to 20 GHz optical bandwidth With its clock recovery option the 80C01 provides testing solutions for 622 and 2488 Mb s telecom applications 800602 High performance Tel
6. 488 Gb s 0C 192 STM 64 9 953 Gb s 1 1100 nm to 1650 nm 1310 nm and 1550 nm 20 nm 80C02 10 Gb s Telecom 0C 192 STM 64 9 953 Gb s 10GBASE W 9 953 Gb s 1100 nm to 1650 nm 1310 nm and 1550 nm 20 nm 80C07B Tributary Datacom Telecom Standard Included 0 48 5 16 2 488 Gb s InfiniBand 2 GbE 2 500 Gb s Optional choose any two OC 3 STM 1 155 Mb s OC 12 STM 4 622 Mb s FibreChannel 1 063 Gb s GbE 1 250 Gb s 2G FibreChannel 2 125 Gb s 700 nm to 1650 nm 780 nm 850 nm 1310 nm and 1550 nm 20 nm 80C08C 10 Gb s Datacom Telecom 0C 192 STM 64 9 953 Gb s 10GBASE W 9 953 Gb s 10GBASE R 10 31 Gb s 10G FibreChannel 10 52 Gb s ITU T G 975 FEC 10 664 Gb s ITU T G 709 10 709 Gb s 10 GbE FEC 11 1 Gb s 700 nm to 1650 nm 780 nm 850 nm 1310 nm and 1550 nm 20 nm 80C10 40 Gb s Telecom 0C 768 STM 256 39 813 Gb s ITU T G 709 FEC 43 018 Gb s 1310 nm and 1550 nm 1310 nm and 1550 nm 20 nm 80011 10 Gb s Datacom Telecom OC 192 STM 64 9 953 Gb s 10GBASE W 9 953 Gb s 10GBASE R 10 31 Gb s 10G FibreChannel 10 52 Gb s ITU T G 975 FEC 10 664 Gb s ITU T G 709 10 709 Gb s 10 GbE FEC 11 1 Gb s 1100 nm and 1650 nm 1310 nm and 1550 nm 20 nm 80C12 FibreChannel Datacom rates between 2 5 Gb s Option 10G 0C192 STM64 9 953 Gb s 10GBase W 9 953 Gb s and 10 Gb s 10GBase R 10 31 Gb s Opt
7. Optical Signal Analysis www tektronix com optical connector is female 2 4 mm and an adapter is provided 2 4 mm male to 2 92 mm female to maintain compatibility with SMA connector systems 80E02 Low noise Sampling Module The 80E02 is a dual channel 12 5 GHz sampling module specifically designed for low noise measurements in digital commu nications and device characterization appli cations It provides an acquisition rise time of 28 ps and typically 400 HVpus of dis played noise The 80E02 is the ideal instru ment for low noise applications Common applications for the 80E02 are capturing and displaying switching characteristics of high speed communications circuits making accurate statistical measurements of signal noise and signal timing jitter or obtaining stable timing measurements of fast digital ICs 80E03 Sampling Module The 80 03 is a dual channel 20 GHz sampling module This sampling module provides an acquisi tion rise time of 17 5 ps 80E04 TDR Sampling Module The 80E04 is a dual channel 20 GHz sampling module with TDR capability This sampling module provides an acquisition rise time of 17 5 ps with a typical 20 GHz equivalent bandwidth The TDR feature provides high resolution with true differential capability and fast 35 ps reflected rise time of the TDR slope 80E06 70 GHz Sampling Module The 80E06 is a single channel 70 GHz typical bandwidth sampling module with 5 0 ps calculated
8. step transition 1 or less over the zone 5 ns to 100 ns following step transition 0 5 after 100 ns following step transition 80E03 10 mV to 1 0 V 2 mV 0 007 Offset 3 or less over the zone 10 ns to 20 ps before step transition 600 pV lt 1 2 mV full scale 0 02 Vertical Value Offset 10 5 or less for the first 300 ps following step transition maximum 3 or less over the zone 300 ps to 5 ns following step transition 1 or less over the zone 5 ns to 100 ns following step transition 0 5 after 100 ns following step transition 80E04 10 mV to 1 0 V 2 mV 0 007 Offset 3 or less over the zone 10 ns to 20 ps before step transition 600 pV lt 1 2 mV full scale 0 02 Vertical Value Offset 10 5 or less for the first 300 ps following step transition maximum 3 or less over the zone 300 ps to 5 ns following step transition 1 or less over the zone 5 ns to 100 ns following step transition 0 5 after 100 ns following step transition 80E06 10 mV to 1 0 V 2 mV 0 007 Offset 5 or less for first 300 ps following step transition 1 8 mV 2 4 mV full scale 0 02 Vertical Value Offset maximum 5 Values shown are warranted unless printed in an italic typeface which represents a non warranted characteristic value that the instrument will typically perform to gt TDR System 80EO4 only UN 80E04 Channels 2 Input Impedance 50 0 5 Q Channel Input Connector 3 5 mm
9. 2 0 V 14 bits full scale 80E02 lt 28 ps 1 0V 1 6V 3 0V 14 bits full scale 80E03 lt 17 5 ps 1 0V 1 6V 3 0V 14 bits full scale 80E04 lt 17 5 ps 1 0V 1 6V 3 0V 14 bits full scale 80E06 5 0 ps 1 0V 1 6V 2 0 V 14 bits full scale Rise time is calculated from the formula Rise time 0 35 Bandwidth bandwidth is calculated from the formula Bandwidth 0 35 Rise time Optical Signal Analysis www tektronix com optical 9 Communications Signal Analyzer gt CSA8000B gt Electrical Sampling Module Characteristics continued UN Vertical Sensitivity DC Vertical Voltage Typical Step Response Aberrations RMS Noise Range Accuracy Single Point Within 2 C of Compensated Temperature 80E01 10 mV to 1 0V 2 mV 0 007 Offset 3 or less over the zone 10 ns to 20 ps before step transition 1 8 mV 2 3 mV full scale 0 02 Vertical Value Offset 412 5 or less for the first 300 ps following step transition maximum 5 5 3 or less over the zone 300 ps to 3 ns following step transition 1 or less over the zone 3 ns to 100 ns following step transition 0 5 after 100 ns following step transition 80E02 10 mV to 1 0 V 2 mV 0 007 Offset 3 or less over the zone 10 ns to 20 ps before step transition 400 pV lt 800 full scale 0 02 Vertical Value Offset 10 5 or less for the first 300 ps following step transition maximum 3 or less over the zone 300 ps to 5 ns following
10. 7225 2 5 GHz Active Probe P6209 4 GHz Active FET Probe P6150 9 GHz Passive Probe 80A01 Pre scaled Trigger Amplifier The 80A01 Pre scaled Trigger Amplifier provides enhanced triggering capability on low level signals up to 12 5 Gb s This module plugs into any of the four available electrical sampling module slots on the TDS8000B and the CSA8000B mainframes It is ideally suited for component designers and manu facturers who are verifying the performance of optical and electrical components that run at non standard clock rates up to 12 5 GHz 80A03 TekConnect Probe Interface Module The 80A03 TekConnect Probe Interface Module provides an interface to Tektronix P7000 series high performance active and differential probes with 3 GHz bandwidths and higher The 80A03 accepts up to two P7000 series probes and one electrical sampling module It plugs into any of the four available electrical sampling module slots on the TDS8000B and CSA8000B mainframes The 80A03 and P7000 series probes are ideally suited for probing directly on IC pins traces or test points that are not accessible through a connector K4000 Mobile Workstation Optical Signal Analysis www tektronix com optical 11 Communications Signal Analyzer Contact Tektronix gt CSA8000B ASEAN Australasia Pakistan 65 6356 3900 Austria 43 2236 8092 262 Belgium 32 2 715 89 70 Brazil amp South America 55 11 3741 8360
11. Above 9 Gb s and 9 GHz 3 4 yW Above 9 Gb s and 9 GHz 6 pW gt 24 dB 9 um single mode Offset Power Power Power Meter Mask Test Capability Meter Meter Range Accuracy Optical Sensitivity 80C01 Standard Standard 4 dBm to 30 dBm 5 of reading 8 dBm at 622 Mb s 2 488 Gb s 9 953 Gb s 5 0 dBm at 20 GHz 80C02 Standard Standard 4 dBm to 30 dBm 5 of reading 9 dBm at 9 953 Gb s 7 dBm at 20 GHz 4 dBm at 30 GHz 80C07B Standard Standard 4 dBm to 30 dBm 5 of reading 22 dBm at 155 Mb s 622 Mb s 20 dBm at 2488 2500 Mb s 80C08C Standard Standard 0 dBm to 30 dBm 5 of reading 15 dBm at all filter rates 80010 Standard Standard 13 dBm to 21 dBm 5 of reading 0 dBm at 39 813 Gb s 43 018 Gb s 0 dBm at 30 GHz 3 dBm at 65 GHz 80011 Standard Standard 4 dBm to 30 dBm 5 of reading 10 dBm at all filter rates 7 dBm at 20 GHz 4 dBm at 30 GHz 80012 Standard Standard 0 dBm to 30 dBm 5 of reading Below 9 Gb s 15 dBm Above 9 Gb s and 9 GHz 12 dBm Smallest power level for mask test Values represent theoretical typical sensitivity of NRZ eyes for competitive comparison purposes Assumes instrument peak peak noise consumes most of the mask margin 8 Optical Signal Analysis www tektronix com optical Communications Signal Analyzer CSA8000B gt Physical Characteristics for Electrical Sampling Modules E Dimensions mm inches Weight
12. Canada 1 800 661 5625 Central Europe amp Greece 43 2236 8092 301 Denmark 45 44 850 700 Finland 358 9 4783 400 France amp North Africa 33 0 1 69 86 80 34 Germany 49 221 94 77 400 Hong Kong 852 2585 6688 India 91 80 2275577 Italy 39 02 25086 1 Japan 81 3 6714 3010 Mexico Central America amp Caribbean 52 55 56666 333 The Netherlands 31 0 23 569 5555 Norway 47 22 07 07 00 People s Republic of China 86 10 6235 1230 Poland 48 0 22 521 53 40 Republic of Korea 82 2 528 5299 Russia CIS amp The Baltics 358 9 4783 400 South Africa 27 11 254 8360 Spain 34 91 372 6055 Sweden 46 8 477 6503 4 Taiwan 886 2 2722 9622 United Kingdom amp Eire 44 0 1344 392400 USA 1 800 426 2200 USA Export Sales 1 503 627 1916 For other areas contact Tektronix Inc at 1 503 627 7111 Updated 23 December 2003 Our most up to date product information is available at www tektronix com ge 150 9001 Product s are manufactured C in ISO registered facilities amp Copyright 2004 Tektronix Inc All rights reserved Tektronix products are covered by 05 and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or regis tered tra
13. Communications Signal Analyzer CSA8000B Communications Signal Analysis Solutions Specifically designed for high performance communications applications the CSA8000B Communications Signal Analyzer is the ideal tool for design evaluation and manu facturing test of datacom and telecom components transceiver subassemblies and transmission systems The CSA8000B generates measurement results not just raw data with time and amplitude histograms mask testing and statistical measurements It provides a communications tailored measurement set that includes jitter noise duty cycle overshoot undershoot extinction ratio Q factor mean optical power and ampli tude measurements for both RZ and NRZ signals In addition mask testing of SDH SONET Gigabit Ethernet and other standards simplifies conformance testing A large full color display helps you to discriminate waveform details Color grading of waveform data adds a third dimension sample density to your signal acquisitions and analyses 1 Optical Signal Analysis e www tektronix com optical Modularity and Flexibility The CSA8000B supports a large and grow ing family of optical and electrical plug in modules This modular architecture lets you configure the instrument with the right features for your application both now and in the future The available optical modules provide complete optical test solutions for both telecom 155 Mb s to 43 Gb s and dat
14. a com FibreChannel InfiniBand and Gigabit Fthernet applications Each optical module includes all of the elements necessary for communications testing including an optical to electrical converter an average power monitor up to five data rate filters a full bandwidth path and a low noise electrical sampler In addition clock recovery is available as an option for most optical modules The electrical plug ins include a variety of modules with bandwidths up to 70 GHz and specialized features such as Time Domain Reflectometry TDR High bandwidth probes are also available for constructing a total acquisition and measurement solution gt Features amp Benefits P Applications Bandwidth is determined by plug in modules and Automatic Communication Measurements RZ and NRZ Q factor Extinction Ratio Optical Power Signal to Noise Ratio Jitter Wide Bandwidth DC to 70 GHz with up to 12 5 GHz Trigger Automatic ITU ANSI Mask Testing ONILNdWO09 z c gt 4 e 7 Norrmal Infinite Variable Persistence and Color Graded Display Modes Intuitive User Interface Large Color Display 10 in MS Windows Operating System Modular Architecture Fast Acquisition Rate Excellent Signal Fidelity Jitter 800 fsec RMS Typical FrameScan Acquisition Mode Isolate Data Dependent Faults Examine Low power PRBS Signals Eliminate Random Noise a
15. demarks of their respective companies 01 04 HBAWWW 85W 13499 9 12 Optical Signal Analysis www tektronix com optical Tektronix Enabling Innovation 2 N
16. ecom Sampling Module The 80C02 module is optimized for testing of long wavelength 1100 to 1650 nm signals at 9 953 Gb s SONET OC 192 SDH STM 64 With its high optical bandwidth of 30 GHz typical it is also well suited for general purpose high performance optical component testing The 80C02 can be optionally configured with clock recovery that supports 9 953 Gb s telecom standards 80C07B Multi rate Datacom amp Telecom Optical Sampling Module The 80C07B module is a broad wavelength 700 to 1650 nm multi rate optical sampling module optimized for testing datacom telecom signals from 155 to 2500 Mb s With its amplified O E converter design this module provides excellent signal to noise perform ance allowing users to examine low power optical signals The 80C07B can be optionally configured with clock recovery that supports 155 622 1063 1250 2125 2488 2500 and 2666 Mb s rates 80C08C Multi rate Datacom amp Telecom Optical Sampling Module with 10 GbE Forward Error Correction The 80C08C module is a broad wavelength 700 to 1650 nm multi rate optical sampling module providing datacom rate testing for 10GbE applications at 9 953 10 3125 11 0957 Gb s and 10G FibreChannel applications at 10 51875 Gb s The 80C08C also provides telecom rate testing at 9 953 10 664 and 10 709 Gb s With its ampli fied O E converter design this module pro vides excellent signal to noise performance and hig
17. ew 80C01 gt 30 dB Single mode 8 0 uW at 622 Mb s 12 0 pW at 622 Mb s Standard 2 488 Gb s 9 953 Gb s 2 488 Gb s 9 953 Gb s 12 5 GHz 15 0 pW at 20 GHz 12 5 GHz 25 pW at 20 GHz 80C02 gt 30 dB single mode 6 0 pW at 9 953 Gb s 10 0 pW at 9 953 Gb s Standard 12 5 GHz 10 0 pW at 12 5 GHz mode 15 pW at 20 GHz 15 0 uW at 30 GHz 20 GHz 30 at 30 GHz 80C07B gt 14 dB multi mode single or multi mode 0 50 pW at 155 Mb s 1 0 pW at 155 Mb s Standard gt 24 dB single mode 622 Mb s 1063 Mb s 622 Mb s 1063 Mb s 1250 Mb s 0 70 pW at 1250 Mb s 2 488 2 500 Gb s 1 5 at 2 488 2 500 Gb s 80C08C gt 14 dB multi mode 224 dB single mode single or multi mode 1 7 pW at all filter rates 3 0 pW at all filter rates Standard 80C10 gt 30 dB single mode 40 pW at 39 813 Gb s 60 uW at 39 813 Gb s Standard 43 018 Gb s 1550 nm 43 018 Gb s 1550 nm 75 pW at 39 813 Gb s 110 pW at 39 813 Gb s 43 018 Gb s 1310 nm 43 018 Gb s 1310 nm 30 pW at 30 GHz mode 50 uW at 30 GHz 1550 nm 55 pW at 1550 nm 90 pW at 30 GHz mode 1310 nm 30 GHz 1310 nm 85 uW at 65 GHz mode 120 pW at 65 GHz 1550 nm 150 pW at 1550 nm 220 pW at 65 GHz mode 1310 nm 65 GHz 1310 nm 80011 gt 30 dB single mode 5 5 pW at all filter rates 8 0 pW at all filter rates Standard 10 0 pW at 20 GHz 14 0 pW at 20 GHz 20 0 uW at 30 GHz 30 0 uW at 30 GHz 80C12 gt 14 dB single or multi mode Below 9 Gb s 1 7 pW Below 9 Gb s 3 uW Standard 62 5 um multi mode
18. ft 155 52 Mbis Electromagnetic Compatibility 89 336 UCI D AQUMUS Safety UL3111 1 CSA1010 1 EN61010 1 STM 16 0C 48 2 4883 61010 1 STM 64 0C 192 9 9533 n Physical Characteristics STM 256 0C 768 39 81312 for Optical Sampling FEC 2 666 2 66606 Modules FEC 10 66 10 6642 Dimensions Weight mm inches kg Ib FEC 10 709 10 709 Width Height Depth Net FEC 43 Gb s G 709 43 018 80601 165 65 25 1 0 305 12 0 lt 2 61 lt 5 75 FEC 42 66 42 656914 80C02 165 65 25 1 0 305 12 0 lt 2 61 lt 5 75 FC 10 G 10 51875 80C07B 165 65 25 1 0 305 12 0 lt 1 36 lt 3 0 80C08C 165 65 25 1 0 305 12 0 lt 1 22 lt 2 7 133 132 813 Mb s 80C10 165 65 25 10 305 120 gt 2 61 gt 5 75 FC 266 265 6 Mb s 80C11 165 65 25 100 305 12 0 lt 1 22 lt 2 7 FC 531 531 2 Mb s 80C12 165 65 25 1 0 305 120 lt 2 61 lt 5 75 FC 1063 1 0625 FC 2125 2 125 FC 4250 4 250 10 G BASE X4 3 125 10 G BASE W 9 95328 10 G BASE R 10 3125 10 GbE FEC 11 097 InfiniBand 2 500 Gigabit Ethernet 1 2500 Optical Signal Analysis www tektronix com optical 5 Communications Signal Analyzer gt CSA8000B gt Optical Sampling Module Characteristics Refer to Optical Sampling Module User Manual for more detailed information Application Type Standard and Supported Data Filtering Rates Number of Input Channels Effective Wavelength Range Calibrated Wavelengths 80C01 Tributary Telecom OC 12 STM 4 622 Mb s 0 48 6 16 2
19. h optical sensitivity allowing users to examine low power level optical signals The 80 08 can be optionally configured with clock recovery options that can support any standard or user defined rate in the continuous range from 9 8 to 12 6 Gb s 80C10 65 GHz 40 Gbps Optical Sampling Module with 43 Gbps ITU T G 709 Forward Error Correction The 80C10 module provides integrated and selectable reference receiver filtering enabling confor mance testing at either 1310 nm or 1550 nm for 39 813 Gbps OC 768 STM 256 and 43 018 Gbps 43 Gbps ITU T G 709 FEC rates In addition to the filter rates the user may also choose selectable band widths of 30 GHz or 65 GHz for optimal noise vs bandwidth performance for accu rate signal characterization 80C11 Multi rate Datacom amp Telecom Optical Sampling Module The 80C11 module is a long wavelength 1100 to 1650 nm multi rate optical sampling module optimized for testing 10 Gb s datacom and telecom standard rates at 9 953 10 3125 Optical Signal Analysis e www tektronix com optical 3 Communications Signal Analyzer gt CSA8000B 10 51875 10 664 10 709 and 11 0957 Gb s With its high optical bandwidth of up to 30 GHz typical it is well suited for gen eral purpose high performance 10 Gb s optical component testing The 80011 can be optionally configured with clock recovery options that can support any standard or user defined rate in the continuous range
20. ion 10G 10 Gb s 10 GFC 10 51 Gb s multistandard G 975 FEC 10 66 Gb s low cost G 709 FEC 10 71 Gb s 10 GbE FEC 11 10 Gb s Option F1 1 063 Gb s 2 125 Gb s 4 25 Gb s FC Option F2 2 125 Gb s 4 25 Gb s FC 9 GHz Option F3 1 063 Gb s 2 125 Gb s FC 9 GHz Option F4 2 125 Gb s 10GBase LX4 3 188 Gb s 4 25 Gb s FC Option F5 10GBase LX4 3 188 Gb s 4 25 Gb s FC 9 GHz Option F6 2 125 Gb s FC 10GBase LX4 3 188 Gb s 9 GHz Option FC 11GBase LX4 filter 3 188 Gb s 3 318 GHz 9 GHz 700 nm to 1650 nm 850 1310 and 1550 nm x20 nm 6 Optical Signal Analysis www tektronix com optical Communications Signal Analyzer gt CSA8000B gt Optical Sampling Clock Recovery Clock Recovery Unfiltered Optical Module Characteristics continued Absolute Maximum Internal Fiber Optional Outputs Bandwidth Nondestructive Diameter Optical Input 80C01 Option CR 622 Mb s Clock Data 20 GHz 5 mW average 9 um 125 single mode 2 488 Gb s 10 mW peak power at wavelength of highest relative responsivity 80C02 Option CR 9 953 Gb s Clock 28 GHz 5 mW average 9 um 125 single mode Clock 16 Data 10 mW peak power at wavelength of highest relative responsivity 80C07B Option CR1 155 Mb s x Clock Data 2 5 GHz 5 mW average 62 5 um 125 multi mode 622 Mb s 1 063 60 5 10 mW peak power at 1 250 60 5 2 125 Gb s wavelength of 2 488 Gb s 2 500 Gb s highest res
21. l e 11111 111 Clock Electrical Recovery lil em ff 2 re sep pe ue Eo Peas ges en pen pepe estes ene peg 2 2 SOE CODO 0 8 8 Electrical Modules Optical Signal Analysis www tektronix com optical Superior Performance With its industry best horizontal timebase stability trigger jitter signal sensitivity and noise performance the CSA8000B ensures the most accurate acquired signal for high speed optical communications testing The CSA8000B s multi processor architec ture with dedicated per channel digital signal processors DSP also provides industry best waveform acquisition rates that shorten test times The CSA8000B s FrameScan acquisition mode can be used with a variety of BERTs and or protocol analyzers to isolate pattern dependent effects in transmitters or show the bit sequence leading up to a mask violation FrameScan acquisition mode also allows averaging of eye diagrams This can be used to extract a clean eye diagram from noisy low level signals 8000 Series Sampling Oscilloscope Platform The CSA8000B is built on Tektronix sampling oscilloscope platform that com bines familiar MS Windows based PC technologies with world class waveform acquisition technology This platform provides a wide array of standard instrumentation and communica
22. n D1 Calibration data report Option D3 Three years of Calibration data reports Option GT Gated Trigger Option R3 Extended repair warranty to three years Option 1K Cart Option 1R Rackmount kit includes hardware tooling and instructions for converting bench model to rackmount configuration Communications Signal Analyzer International Power Plug Options Option AO North America power Option A1 Universal EURO power Option A2 United Kingdom power Option A3 Australia power Option A4 240 V North America power Option A5 Switzerland power Option A99 No power cord or AC adapter Option AC China power Other Accessories Calibration Step Generator with Power Cords Std US 067 1338 00 A1 Europe 067 1338 01 A2 UK 067 1338 02 A3 Australia 067 1338 03 A4 North America 067 1338 04 A5 Switzerland 067 1338 05 A6 Japan 067 1338 06 80A02 TDS CSA8000 Series EOS ESD Protection Module 1 channel Sampling Module Extender Cable 1 meter Order 012 1568 00 Sampling Module Extender Cable 2 meter Order 012 1569 00 2X Attenuator SMA male to female Order 015 1001 01 CSA8000B 5X Attenuator male to female Order 015 1002 01 Adapter 2 4 mm male to 2 92 mm female Order 011 0157 00 Power Divider Order 015 1014 00 Rackmount Kit Order 016 1791 01 P8018 20 GHz Single ended TDR Probe P
23. nd Jitter Via Averaging Windows 2000 for Enhanced Network Security Manufacturing Testing for ITU ANSI Conformance Designing Verification of Telecom and Datacom Elements may exceed 70 GHz should higher speed modules become available in the future Tektronix Enabling Innovation Communications Signal Analyzer gt CSA8000B 8000 Series Module Matrix Rates Supported g Filter Optical Clock Recovery o Electrical Clock Recovery Ce Fuoco s 1100 1650 9 700 1650 700 1650 00 1650 9 amp 62 5 700 1650 00 1650 700 1650 00 1650 700 1650 o amp 62 700 1650 9 amp 62 5 00 1650 9 amp 62 5 Il 1 700 1650 9 amp 62 5 700 1650 9 amp 62 5 700 1650 00 1650 9 amp 62 5 lt 1290 1330 530 1570 w jnjs w t3 aje N Un n A A N Optical Modules e e 2 5 5 8 a Is m RI Em 1100 1650 BN 1 100 1650 9 noie o pref s v 2 un 2 1516 700 1650 1650 9 amp 62 5 00 1650 9 amp 62 00 1650 700 1650 9 amp 62 5 700 1650 700 1650 700 1650 rameus sion Le lelelelelelelelelelelelelelelele 1 E i2 9 to s 9 e un mI Lll liil n
24. on typical lt 2 5 psaus 0 01 ppm of position max Internal Clock Adjustable from 25 to 200 kHz drives TDR internal clock output and calibrator Trigger Level Range 1 0 V Trigger Input Range 1 5 V Trigger Holdoff Adjustable 5 us to 100 ms i 2 ns increments 5 External Trigger Gate optional TTL logic enables gate a TTL logic 0 disables gate maximum non destruct input level 5 V Display Features Touch Screen Display 10 4 in diagonal color Colors 16 777 216 24 bits Video Resolution 640 horizontal by 480 vertical displayed pixels Math Measurement System Measurements The CSA8000B supports up to eight simultaneous measurements updated three times per second with optional display of per measurement statistics min max mean and standard deviation Measurement Set Automated Measurements include RZ NRZ and Pulse signal types and the following Amplitude Measurements High Low Amplitude Max Mid Min Width Eye Height Eye Opening Factor Pulse Symmetry Peak to Peak Pk Pk Overshoot Overshoot Mean Duty Cycle Cycle Mean RMS Cycle RMS AC RMS Gain Extinction Ratio Ratio dB Suppression Ratio Ratio dB Peak to Peak Noise RMS Noise Q Factor SNR Average Optical Power dBm watts Phase Optical Modulation Amplitude Timing Measurements Rise Fall Period Bit Rate Bit Time Frequency Crossing Level Time Cross
25. ponsivity 2 666 Gb s 80C08C Option CR1 9 953 Gb s Clock Clock 16 10 GHz 1 mW average Single mode and 10 31 Gb s 10 mW peak power at multi mode fibers up Option CR2 10 31 Gb s wavelength of to core diameter 10 52 Gb s highest responsivity of 62 5 um Option CR4 Continuous from 9 8 Gb s to 12 6 Gb s 80010 Future Upgradeable Future 65 GHz 20 mW average 9 um 125 single mode 60 mW peak power at wavelength of highest relative responsivity 80C11 Option CR1 9 953 Gb s CR1 Clock Clock 16 Data 28 GHz 5 mW average 9 um 125 single mode Option CR2 9 953 Gb s CR2 CR3 CR4 10 mW peak power at 10 664 Gb s Clock Clock 16 wavelength of Option CR3 9 953 Gb s highest responsivity 10 709 Gb s Option CR4 Continuous between 9 8 Gb s to 12 6 Gb s 80012 Provided by 16 10G Clk 4 to 10 Gb s 1 mW average 10 mW Single mode and separately sold 80A05 depending peak power at wavelength multi mode fibers up 50 Mb s to 12 6 Gb s on option of highest responsitivity to core diameter of 62 5 um Values shown are warranted unless printed in an italic typeface which represents a typical value Optical Signal Analysis www tektronix com optical 7 Communications Signal Analyzer gt CSA8000B gt Optical Sampling Module Characteristics continued Optical Fiber Input RMS Optical Noise RMS Optical Noise Independent Return Loss Accepted typical maximum Channel Desk
26. rise time Typical RMS noise is 1 8 mV This sampling module provides a 1 85 mm Type V front panel connector and a precision adapter to 2 92 mm with a 50 Q SMA termination 1 meter or 2 meter length Extender Cables can be ordered for remote operation of the sampling module from the sampling oscilloscope mainframe 80A05 Electrical Clock Recovery Module The 80A05 enables clock recovery for elec trical signals as well as internal triggering on the recovered clock The module recov ers clocks from serial data streams for all of the most common electrical standards in the 50 Mb s to 4 26 Gb s range Option 10G adds support for standard rates up to 12 6 Gb s The module accepts either sin gle ended or differential signals at its input providing both single ended and differential clock recovery This module also serves as the clock recovery module for the 80C12 gt Characteristics Signal Acquisition Acquisition Modes Sample normal envelope and average Number of Sampling Modules Accommodated Up to four dual channel electrical and two single channel optical sampling modules Number of Simultaneously Acquired Inputs Eight channels maximum eight electrical or two optical and six electrical Vertical Systems Rise Time Bandwidth Determined by the sampling modules used Vertical Resolution 14 bits over the sampling modules dynamic range Horizontal System Main and Magnification View Timebase
27. s 1 ps div to 5 ms div in 1 2 5 sequence or 1 ps increments Maximum Trigger Rate 200 KHz Typical Acquisition Rate 150 Ksamples sec per channel Time Interval Accuracy Horizontal scale 21 ps div 1 ps 1 of interval Horizontal scale gt 21 ps div 8 ps 0 1 of interval short term optimized mode 8 ps 0 01 of interval locked to 10 MHz mode Horizontal Deskew Range 500 ps to 100 ns on any individual channel in 1 ps increments Record Length 20 50 100 250 500 1000 2000 or 4000 samples Magnification Views In addition to the main time base the CSA8000B supports two magnification views These magnifications are independently acquired using separate timebase settings which enable higher resolution sampling Trigger System Trigger Sources External direct trigger External pre scaled trigger Internal clock trigger Internally connected to direct trigger Clock recovery triggers from optical sampling mod ules internally connected to pre scaled trigger Trigger Sensitivity External direct trigger output 50 mV DC 4 GHz typical 100 mV DC 3 GHz guaranteed Pre scaled trigger input 800 mV 2 to GHz guaranteed 600 mV 3 to 10 GHz guaranteed 1000 mV 10 to 12 5 GHz typical Jitter Short term jitter optimized mode lt 0 8 PSkus 5 ppm typical lt 1 2 10 ppm max Locked to 10 MHz reference 1 6 PSpus 0 04 ppm of positi

Download Pdf Manuals

image

Related Search

File filezilla files file explorer filevine login file manager filecr filevine filehippo filemaker file converter file folder file transfer filezilla download file sharing file compressor filemaker pro file explorer options filet mignon file associations settings file and serve express login filezilla server files app filehorse filezilla client file explorer this pc

Related Contents

PRO X HZV_ BENUTZERHANDBUCH  Photographier avec son Nikon D750  Samsung GT-P7300/AM16 คู่มือการใช้งาน  Samsung ME732K-B Felhasználói kézikönyv  ISTRUZIONI PER L`USO  DV-DH1000S/DH500S/DH250S 取扱説明書 操作編  Instruction Sheets -- Ashfield 529 Series  hit 69 az hit 69 nz eurohit 69 az eurohit 69 nz  Terratec Cinergy 400 TV mobile PCMCIA  Prospectus  