Home

Meriam M1 Series Digital Manometer/Calibrator

image

Contents

1. M1 Series Digital Manometer Calibrator M1 Series Advantages Engineering Units 8 selectable Inches of H O 20 C mm of H O 20 C mm of Hg 0 C Inches of Hg 0 C kPa mBar Bar PSI and user selectable Media Compatibility Non isolated sensor for clean dry non corrosive gases Pressure Limits DN units 3 x F S on high side only or 200 PSI whichever is less GN or AN units 3 x F S range or 200 PSI whichever is less Accuracy No temperature effect over the entire operating range 14F to 122 F 10C to 50 C Min Max M101 only Displays the MIN and MAX pressures absolute pressure versions Applications TRANSGAT gt Visit us at Transcat com 35 Vantage Point Drive Rochester NY 14624 Call 1 800 800 5001 M1 Series Digital Manometer Calibrator The M1 Series of handheld manometers from Meriam Process Technologies meriam A SCOTT FETZER COMPANY combines form fit and function to deliver precision pressure measurement for field plant or lab use For reference indication and shirt pocket convenience select the low cost M100 Digital Manometer with its 0 25 FS accuracy Or specify the M101 Calibrator when better accuracy is needed for more exacting measurements The M101 delivers 0 10 FS accuracy and additional features normally found on higher priced instruments Both models are available in differential gauge and i Leak testing for low pressure g
2. as systems e Pressure drop monitoring across filters e Monitoring vacuum on condensers or pumps e Verification of CPAP or BIPAP systems for home or hospital settings Hold M101 only Freezes the pressure measurement on the display however the bar graph is still active Ave M101 only Displays a continuous filtered average of the pressure measurements Temp Displays the internal ambient temperature of the M1 in C or F Record Mode The M1 can store up to 240 pressure measurements e Automatic the current value is automatically stored every 5 seconds for up to 20 minutes e Manual the current value is stored every time the Units key is pressed up to 240 times Backlight A green backlight is user activated via the backlight key A red backlight is automatically activated during an error over range condition Auto Shutoff To conserve battery life the M1 will automatically power off after 20 minutes of keypad inactivity Field Recalibration M1 can be calibrated in the field for zero and span Low Battery Indication BAT icon is displayed when batteries require replacement Approximately 2 hours of run time is provided on a low battery condition Bar Graph Horizontal bar for full scale pressure reference 0 100 M1 SERIES A A SCOTT FETZER COMPANY Technical Specifications Base Unit Connections e Lightweight and ergonomic e 1 8 female NPT 316 S S e 12 ounces and 6 0 x 3 0
3. iid Gauge 6 Adapter 1 8 O D Tube to 1 8 MNPT PN A34012 GN0050 0 to 50 00 PSI Gauge A34477 Basic Test Kit Includes GN0100 0 to 100 0 PSI Gauge Nylon Tubing 10 FT PN A34103 2 Adapter Brass Tubing to 1 8 MNPT PN A34102 AN0775 Uh AROE AN1551 0 to 1551 mm Hg Absolute 9A000053 ABS plastic carrying case AN2585 0 to 2585 mm Hg Absolute 9P000058 Spare Protective Boot Red each M1 comes standard with a protective boot Z1055 NIST Traceable Certificate with Data NCAT105 TRANSCAT gt Visit us at Transcat com 35 Vantage Point Drive Rochester NY 14624 Call 1 800 800 5001
4. x 1 0 with ESD All models have a P1 and P2 port GN and AN units e Dissipative polycarbonate have a sintered metal disc installed on P2 Keypad NIST Traceable Accuracy e Sealed membrane type with 4 dome style contact e M100 Digital Manometer 0 25 F S buttons e M101 Calibrator 0 10 F S e Temperature Specifications Storage 40 F to 140 F 40 C to 60 C Certifications Operating 14 F to 122 F 10 C to 50 C e CE Mark comes standard with product a e NIST Traceable Certificate with Data optional m nc m erar Power ts 3 AA batteries providing over 300 hours of continuous Temperature Specifications use e Storage 40 F to 140 F 40 C to 60 C e Operating 14 F to 122 F 10 C to 50 C Ordering Information Type ENE DIGIA Model No amp Description DN0028 0 to 28 00 H20 Differential M100 specify pressure range Digital Manometer DN0138 0 to 138 0 H20 Differential M101 specify pressure range Calibrator DNO416 0 to 416 0 H20 Differential All models include the protective red rubber boot 4 AA batteries and hard copy of the user s manual DN0832 0 to 832 0 H20 Differential Optional Accessories DN2000 0 to 2000 H20 Differential GN0005 0 to 5 000 PSI Gauge A34386 Calibration Kit Includes 3 Nylon tubing 6 ft PN A34103 3 GN0015 0 to 15 00 PSI Gauge 2 Tee Brass 1 8 O D Tubing PN A34112 1 Adapter 3 16 Hose Barb to 1 8 MNPT PN A34142 2 GN0030 a

Download Pdf Manuals

image

Related Search

Related Contents

KRS‐05 Ensemble Combinations Manuel d`utilisation  Labour - Pri  VGN-P series - Sony Europe  de Gebrauchsanweisung Bodenstaubsauger en Vacuum  Written exam for Software Engineering Theory  HP E231e    Programme loisir et culture - printemps 2014 - Ville de Saint  IFC-MBOX2800  Samsung SRT667FBI User Manual  

Copyright © All rights reserved.
Failed to retrieve file