INSTALLATION & PROGRAMMING MANUAL
Contents
1. cT 100 200 SSS OSS SSS OPTIONAL NESS RADIO INTERFACE ECO8x CONNECTION DIAGRAM NOTICE ADSL broadband can interfere with the operation of your alarm dialler It is recommended that a quality ADSL filter be installed as per the filter manufacturer s guidelines Use Ness ADSL Filters 100 006 or 100 009 END OF LINE RESISTORS Ness control panels are supplied with 2200 Ohm 1 tolerance Metal Film end of line resistors Colour code Red Red Black Brown Brown Zone 8 Zone 7 COMMON for zones 5 to 8 Zone 6 Zone 5 Note L Zone 4 Zone commons are NEGATIVE Zone 3 lt COMMON for zones 1 to 4 Zone 2 Zone 1 T c Constant 12V DC power for detectors j AUX1 OUTPUT Programmable for Smoke Detector power default or Areal arm output or Radio Panic output Max current draw 200mA RESET Up to 2 x 12V Screamers STR Up to 2 x Strobe Light Shared COMMON for SIREN STR RESET AUX NOTE This is a POSITIVE common SIREN Up to 3 x 8 Ohm Horn Speaker KEYPAD 2V CLK DA Maji T RESET STR ae AC AC 17V White 8 Black Ness 17V AC Plug Pack Australia only EARTH Yellow Green stripe To program the Aux1 output for Latching Smoke Detector supply turn on options P65E 1E and P62E 4E In normal operating mode Keypress 1E will turn off the Aux1 output for 5 seconds to reset latching s
2. Alarm to Reset output NOTES 2E ON Tamper Alarm to Strobe output A Tamper Alarm is triggered by removing 3E ON Tamper Alarm to Keypad Sonalert output the PROG TAMP link on the main board 4E ON Tamper Alarm to Siren output P61E 5E 8E KEYPAD PANIC ALARM OUTPUT MAPPING PROGRAM MODE LEVEL This option selects which outputs will trigger when a Keypad Panic alarm occurs Installer Remote by PC PROGRAMMING SEQUENCE FACTORY DEFAULT 5E 8E ON P61E 5E 8E toggles the options ON and OFF 5E ON Keypad Panic Alarm to Reset output 6E ON Keypad Panic Alarm to Strobe output TE ON Keypad Panic Alarm to Keypad Sonalert output 8E ON Keypad Panic Alarm to Siren output NOTES Press FIRE amp MEDICAL keys together for Keypad Panic RELATED OPTIONS P64E 6E Enable Keypad Panic 24 Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING Z gt lt m M 1 3 EE M Minen Ern rs E 21 2 gt gt tr lt lt P 85 A 5 3 ss 5 NIV lt lt 5x Sl l lelelelele o a n elelelelelelele o de Hes fi p de 225 gt Option Description 1E 2E 4E 5E 6E 7E 8 P62E OPERATION SHORTCUTS ETC ON ON ON ON SYSTEM OPERATION SHORTCUTS PROGRAM MODE LEVEL Some keypad operations can be programme
3. ioni ke rete 53 PROGRAMMING OPTIONS 54 55 Specifications and 56 INSTALLATION WARNING Installation and maintenance shall be performed by gualified service personnel only CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions on the battery ESD WARNING Electrostatic Discharge Once properly installed Ness control panels are well protected from ESD However take note of the following precautions during installation The human body can generate static electricity when it is insulated from earth for instance by walking over carpet ESD occurs and a small shock is sometimes felt if an earthed metal object is then touched The installer should be aware that if he generates static electricity while installing the panel and then discharges this static electricity into the internal components on the main circuit board or the keypad board then ESD damage may occur The circuit board should not be unwrapped until it is actually ready to be installed Methods to avoid electrostatic build up 1 Use a foot strap a wrist strap or a grounding mat The aim is to connect the body to earth to discharge static before it builds up The connection is a high resistance for personnel safety I
4. The terminal block should STROBE LIGHT b ted inside th ine ee 101900 ALTERNATIVE SWITCH WIRING N C TAMPER SWITCH For N C Tamper Switches 91 1920 Colour WHITE Mul zs ET Ness ECO8x PANEL INSTALLATION MANUAL KEYPAD Ness 8 keypad provides important visual and audible indication of the system status and is the main interface for controlling the many powerful features of the system NUMBER OF KEYPADS Up to 3 keypads can be connected to the ECO8x panel KEYPAD INSTALLATION Connect the wires to the screw terminals as per the wiring diagram shown in this manual The keypad housing can be screwed directly to the wall through the screw holes on the front of the fascia Cover plugs for the mounting holes are supplied Left and right hand cover plugs are different marked L and H on the inside of the plug CABLE LENGTH The maximum allowable cable length is 100m total cable length to all keypads KEYPAD BEEPS BEEPS MEANING J 1 BEEP Any key press KEYPAD DISPLAY INDICATORS IN OPERATING MODE KEYPAD LIGHT ZONE LIGHTS 1 8 OFF Zone is sealed Zone is unsealed Zone is in alarm ARMED Red Illuminated button Panel is disarmed Panel is armed or Area 1 is armed if using Areas HOME Home Mode is Panel is a
5. o ae 3 gt gt 2 2 15 lels lg a a oc LO a x E Option No Description 1E 2E 4E 5E 6E 7E 8 P64E MISC OPTIONS ON ON BRIEF HOME MODE ALARM Alarms in Home Mode can either activate the programmed outputs for Siren Time duration P29E or they can activate the outputs for 2 seconds only NOTE If Brief Home alarm is enabled then Home Mode alarms will not be reported by dialler PROGRAMMING SEQUENCE P64E 1E toggles the option ON and OFF OFF Home Mode outputs have normal time as set by P29E ON Home Mode outputs are ON for 2 seconds only BRIEF DAY ALARM Alarms in Day Mode will activate the programmed outputs while the zone is unsealed or they can activate the outputs for 2 seconds only This option also enables the TEMPORARY DAY ZONE feature See page 18 PROGRAMMING SEQUENCE P64E 2E toggles the option ON and OFF OFF Brief Day Alarm disabled Day alarm outputs are ON while the zone is unsealed ON Brief Day Alarm Enabled Day alarm outputs are ON for 2 seconds only KEYPAD CHIME This option enables the keypad Chime sound for Brief Home Mode Alarm if P64E 1E is enabled and for Day Mode sounds If this option is disabled the normal keypad beep will sound PROGRAMMING SEQUENCE P64E toggles the option ON and OFF OFF Keypad Chime disabled ON Keypad Chime enabled RADIO KEY SIREN CHIRPS If this option is selected the Siren output will Chirp when the panel
6. 3 a gt x lt E x sl 5 2 5 Q 85 cM o Sz 2 29 alag 5 a 32 gt lt la ola o o eel 5 lt 3 lt lt ao an EIE Option No Description 1E 2E 4E 5E 6E 7E 8 P69E MISC OPTIONS 2 ARM1 PULSE OUTPUT ARM1 Output will pulse on for 2 seconds whenever Area is armed Disarming does not pulse the output The Pulse output is instead of the normal toggle action for ARM1 when arming disarming PROGRAMMING SEQUENCE P69E 1E toggles the option ON and OFF OFF 1 output toggles ON ARM1 output pulses ARM2 PULSE OUTPUT ARM Output will pulse on for 2 seconds whenever Area2 is armed Disarming does not pulse the output The Pulse output is instead of the normal toggle action for ARM2 when arming disarming PROGRAMMING SEQUENCE P69E 2E toggles the option ON and OFF OFF ARM2 output toggles ON ARM2 output pulses QUIET HOME MODE SIREN This option selects the Quiet Siren sound in Home Mode The Quiet Siren sound is a continuous beep beep beep sound rather than the normal siren sound PROGRAMMING SEQUENCE P69E toggles the option ON and OFF OFF Normal siren sound in Home Mode ON Quiet Siren sound in Home Mode Ness ECO8x PANEL INSTALLATION MANUAL PROGRAM MODE LEVEL In
7. J2 NOTES The Ness Radio Interface is normally installed inside the control panel box n cases where the receiver needs to be located closer to the transmitters the Ness Radio Interface can be installed up to 50 metres away from the control panel Use 14 0 20 shielded cable or equivalent The shield can either be connected to the EARTH connection or left unconnected Leave the shield unconnected at the receiver end f the Radio Interface must be installed inside a metal enclosure the antenna wire should protrude outside the enclosure For best performance the antenna wire should be kept straight and not coiled shortened or extended The optional 100 046 Whip Antenna can be used in cases where radio reception is marginal The whip antenna may not improve reception in all cases however its reception pattern may better suit the local radio environment RADIO SIGNAL STRENGTH TEST The Signal Strength Test can be used to test the radio signal from any Ness radio device The strength of the radio signal received is displayed on the zone lights 1 8 and beeped by the keypad The higher the number displayed and beeped the stronger the signal received TEST SEQUENCE Enter the option for the radio device to be tested For Radio Keys options 11 25 For Radio Devices options 1 Press Trigger the radio device One of zone lights 1 to 8 will turn ON to indicate the signal strength from
8. P45E P46E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All zones assigned to Area 1 No zones assigned to Area 2 NOTES e For options P45E and P46E Zone E toggles the selection ON and OFF Zones assigned to BOTH areas become Common zones If no Area operation is required assign all zones to Area 1 This is the factory default PROGRAMMING HANDOVER ZONES Handover zones are delayed only if entry is made through an Entry Delay zone first If a Handover zone is triggered first the zone behaves as an instant zone Normally the point of entry zone should be Delay zone with any other zones in the entry path programmed as Handover zones PROGRAMMING SEQUENCE P42E Zone turns the options ON P42E Zone No E ON The zone is a Handover zone To deselect the option select a different zone delay type RESET LOCKOUT ZONES All zones and tamper input can be programmed to Lockout i e cause the RESET OUTPUT to sound only once whilst the panel is armed The RESET OUTPUT is then locked out for that alarmed zone until entering a valid code has reset the panel If using area partitioning disarming either partition resets the zone lockout for both partitions PROGRAMMING SEQUENCE P44E Zone toggles the options ON and OFF PA4E Zone No E OFF The zone is not a Lockout zone PA4E Zone No E ON The zone is a Lockout zone ASSIGNING ZONES TO AREAS ZONES Option No Descripti
9. Medical Alarm Fire Alarm Exit From Installer Pro gram Mode Internal Panel Tamper Keypad Tamper Mains Fail Panel Battery Fail Radio Battery Fail POF PPP MO NINI NI OLN OD ayy wy po NIDJI AJN oO lt AUDIBLE MONITORING While Central Station Monitoring is recommended the panel can also send audible alarm reports to any DTMF capable telephone The types of alarms sent are listed in the Reporting Format Table The basic audible message consists of the warning words ALARM ALARM ALARM followed by the alarm message sent as a series of beeps pause A pause B pause N The first digit of the Account Number P72E N can be the digits 1 9 If P72E starts with O N is not sent A First digit of the Alarm identifier See Reporting Format Table B Second digit of the Alarm identifier See Reporting Format Table MESSAGE EXAMPLE If the Account Number is 1234 and zone 5 alarm is reported then 1 amp 5 are beeped out ALARM ALARM ALARM 1 Beep 5 Beeps REPORTING SEQUENCE When triggered by an alarm event or events the panel will 1 Call the Primary Telephone Number P70E 2 Wait for 6 seconds During this time the warning words ALARM ALARM ALARM are repeated 3 Commence the audible message 4 Repeat the audible message 4 times if not acknowledged by pressing the key aft
10. Remote by PC FACTORY DEFAULT User Code 1 123 All other codes blank NOTES This option DOES NOT clear the Installer Code PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 000000 PROGRAMMING Option No Description P95E CLEAR RADIO DEVICES P96E CLEAR MEMORY P97E CLEAR PANEL OPTIONS RESTORE FACTORY DEFAULTS P98E CLEAR USER CODES P99E PROGRAM INSTALLER CODE CLEAR RADIO DEVICES This option clears all Radio Devices assigned to zones 1 8 This option does not clear User Codes PROGRAMMING SEQUENCE P95E Clears Radio Device Codes CLEAR MEMORY Enter P96E when in Installer Program mode to clear all events in the Alarm memory display PROGRAMMING SEQUENCE P96E Clears Alarm Memory display CLEAR PANEL OPTIONS This option restores panel program options to their factory default values Defaults all options except User Codes Radio Codes amp Radio Devices PROGRAMMING SEQUENCE P97E Restores Factory Defaults CLEAR USER CODES This option clears all User Codes includes all Keypad Codes and Radio Keys and restores User Code 1 to the factory setting of 123 P11E P25E are defaulted User Codes 1 15 PROGRAMMING SEQUENCE P98E Clears User Codes PROGRAM THE INSTALLER CODE Programs the installer code This code can be 3 to 6 digits long Factory default installer code is 000000 PROGRAMMING SEQUENCE P99E Enter new code E Enter new code again E Unlike User Codes t
11. Report Zone Restorals P134E Real Time Clock set YEAR P135E Real Time Clock set DAY OF WEEK Report Misc Restorals Report Multiple Zone alarms Telephone No Callback Ness ECO8x PANEL INSTALLATION MANUAL Ea PACKING LIST ECO8x Main board Housing ECO8x LED keypad 17VAC plug pack 12V 7Ah battery optional Dialler telephone lead User s manual Installation manual End Of Line resistors 2K2 Lead assembly for battery Lead assembly for internal tamper Housing cover screws Circuit board standoffs NESS ECO8x CONTROL PANEL SPECIFICATIONS Box dimensions 235w x 300h x 90d mm Plug pack 240V AC output 17V 1 4 Power supply 13 8V DC 9 800mA Quiescent current draw 80mA with 1 keypad Operating voltage 9 5 14 DC Rechargeable battery 12 volt 7 0 Amp hour Sealed Lead Acid Battery charging current 350mA maximum current limited Dynamic battery test Backup battery is tested under load hourly and on arming i 2 Amp auto resetting Siren output amp Reset output 500mA auto resetting 12 volt auxiliary outputs 200 mA auto resetting strobe output INPUTS ZONES 8 zone inputs 1 x 24hr tamper input End of line resistor 2200 Ohms 2K2 5 19 Multi pin connector for the Ness Radio Int
12. Send RESTORAL after Disarm always TEST CALL Interval 84 168hrs Day Mode to STROBE Day Mode to keypad SONALERT Day Mode to SIREN Brief Home Mode Alarm Brief Day Alarm Enable Keypad Chime Radio Key SIREN CHIRPS 50Hz Mains Frequency Enable Keypad Panic Keypad Fire Alarm Keypad Medical Alarm 1 Smoke Detector Power Aux1 Areal armed output 1 Toggle on Radio AUX button Aux1 Pulse on Radio AUX button P66E 1E 2 4 5E 6E P69E 1E 2E 3E 5E 6E 7E 8E Aux2 Zone alarm output Aux2 Area2 armed output Aux2 Toggle on Radio PANIC button Aux2 Pulse on R adio PANIC button 2 Line Fail output Aux2 Fail To Communicate output 3K3 Zone Resistors Quiet chirps on radio Arm Disarm ARM1 output pulses ARM output pulses P85E P86E P87E P88E P89E P90E 1E 2E 1E 2E 4E 1E 2E 4E 1E 2E 5E 7E 8E 1E 2E 3E 4E 5E 7E 1E 7E 8E Time before FIRST TEST CALL Auto Dialling Pulse amp DTMF 6 12hrs Pulse Dialling Decadic always DTMF Dialling always Disable Dialler CONTACT ID FORMAT Audible Format Split dial Primary Secondary numbers Check for Dial Tone 4 Dialling attempts Send AREA 1 OPEN CLOSE REPORTS Send AREA 2 Open Close reports Forced Opening report Manual Exclude Reports Auto Exclude Reports ENABLE TEST CALLS
13. both Areas have armed The Common Area then automatically disarms when either Area1 or Area2 disarms USER CODE ASSIGNMENT A User Code assigned to an Area can arm and disarm only that Area User Codes as signed to both Areas will operate both Areas simultaneously OPERATION Arming and disarming is carried out as normal from a single keypad or separate keypads installed in both areas or by Radio Key Area operation only applies to zones when they are in the armed state This means that Day zones and 24hr zones are independent of area operations TEMPORARY DAY ZONES The Temporary Day Zone feature allows easy and flexible Day Zone selection and operation While remaining in normal operating mode the user can add and remove Temporary Day Zones and enable disable day zone operation using simple key strokes TO ENABLE TEMPORARY DAY ZONES To enable Temporary Day Zone selection and operation the Brief Day Alarm feature installer option P64E 2E must be ON If P64E 2E is OFF the Temporary Day Zone feature will be unavailable but Permanent Day Zones will still operate and will sound the programmed output while the zone is unsealed P64E 2E is OFF by default USER COMMANDS normal Operat ing Mode Selection Mode Enter followed by E when in operating mode to enter Temporary Day Zone selection mode Zone No Zone Selection To select AREA PARTITIONING amp HOME MODE The panel can
14. 2nd call verify the caller hang up and RELATED OPTIONS then make the Callback using Telephone Number 4 1E Enable Upload Download PROGRAMMING SEQUENCE P81E Telephone Number Callback P90E 8E toggles the option ON and OFF OFF No Callback ON Callback Mode enabled Option No Description Default Note REQUIRED RINGS PROGRAM MODE LEVEL Sets the number of rings before an incoming call is answered This is used for remote Installer Remote by PC access of the panel either by NessComms software or user operation by telephone FACTORY DEFAULT Programmable from 1 to 24 rings Enter a value between 1 and 24 1 PROGRAMMING SEGUENCE NOTES P91E existing Required Rings value is displayed one digit at a time The Australian double ring tone is ENTER NEW VALUE E new Required Rings value is displayed one digit at a time counted as one ring RELATED OPTIONS P90E 1E 7E 8E Remote Access options 44 Ness ECO8x PANEL INSTALLATION MANUAL These options allow selective restoring of various factory defaults For ekample you can default clear all the User Codes without affecting any other programmed options PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable NOTES P98E PROGRAM MODE LEVEL Installer
15. Code its Keypad Code if any is automatically deleted PROGRAMMING SEQUENCE In Installer Program Mode enter the option number for the user code which will be become a radio code Example enter P25E for user code 15 Press EXCLUDE E to enter Extra Options mode The Exclude light is on Press 5E to enable that user code as Radio Code Light 5 is on Press EXCLUDE E to exit Extra Options mode The Exclude light is off Q Press 1E The READY light will turn ON to indicate that the User Code is ready to accept the Radio Key If a code is already programmed the READY light will not turn on and a warning beep will sound To clear the code press OE then go back to step 5 OE clears any existing codes Q Press the OFF button on the Radio Key to be programmed If the Radio Key is accepted the READY light will turn off and 3 beeps will sound If the READY light stays on and a warning beep sounds the Radio Key is already assigned to another EXAMPLE To enable User Code 15 as a Radio Code and program a Radio V In Installer Program Mode Press P25E EXCLUDE E 5E EXCLUDE E 1E then press the OFF button on the nadlo AC TO DELETE A RADIO CODE Any Radio Code can be deleted if necessary lost radio key or if programming a radio key over an old one And a Radio Code is automatically deleted when the user code type is changed to keypad code or reader code EXAMPLE To delete Radio Code 15 In Installer Program Mode
16. KEYPAD PANIC This option enables the operation of Keypad Panic Pressing both the FIRE amp MEDICAL keys together activates a Panic alarm PROGRAMMING SEQUENCE P64E 6E toggles the option ON and OFF OFF Keypad Panic disabled ON Keypad Panic enabled KEYPAD FIRE ALARM This option enables the operation of the keypad Fire Alarm A Fire alarm is activated by pressing the FIRE key followed by E The SIREN output changes to the FIRE sound If P75E 4E is enabled the fire alarm is reported by dialler to the central station PROGRAMMING SEQUENCE P64E 7E toggles the option ON and OFF OFF No Keypad Fire Alarm ON Keypad Fire Alarm enabled KEYPAD MEDICAL ALARM This option enables the operation of the keypad Medical Alarm A Medical alarm is activated by pressing the MEDICAL key followed by E The keypad medical alarm can send a Medical Alarm report by dialler The option P75E 2E must be enabled for the Medical alarm to be reported PROGRAMMING SEQUENCE P64E 8E toggles the option ON and OFF OFF No Keypad Medical Alarm ON Keypad Medical Alarm enabled Ness 8 PANEL INSTALLATION MANUAL AUX1 Output on the main terminal strip KEYPAD 12V COM CLK D T RESET STR SOSSS OSE PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES The AUX1 output can supply 200mA max An external power supply should be added if the total current draw o
17. No ON The zone will trigger the Siren output AUX2 OUTPUT ZONES Selects the zones to trigger the AUX2 output on the main board This option selects which zones trigger AUX2 Once turned on by a zone alarm the output will remain on until the panel is reset disarmed PROGRAMMING SEQUENCE P59E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the AUX2 output Zone No ON The zone will trigger the AUX2 output Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON NOTES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES e The keyswitch always Arms Area1 only The keyswitch always Disarms both Area1 and 2 The keyswitch option is compatible only with 2k2 resistors The option will NOT work if the 3k3 Resistor option P68E 2 is enabled 5 8 g 2 2 8 5 Bd NIS 5 5 0 ee 3 E Be 99 c Oc 5 x Lr lt lt Option Description 1E 2E 4E 5E 6E 7E 8 P60E VARIOUS OPTIONS ON ON ON ENTRY BEEPS The sonalert will beep during Entry Delay PROGRAMMING SEQUENCE P60E 1E 000 65 the option ON and OFF OFF Entry Beeps OFF ON Entry Beeps ON KEYSWITCH OPERATION An externally fitted normally open momentary Keyswitch can be used to Arm and Disarm the ECO8x Th
18. ON The option is toggled off by selecting a different P65E option for Aux1 AUX1 OUTPUT TOGGLE ON RADIO KEY AUX BUTTON When this option is on RK4 Radio Key s AUX button will TOGGLE the AUX1 output The output will operate independently of the panel s armed status ie disarming does not turn Aux1 off PROGRAMMING SEQUENCE P65E SE turns the option ON The option is toggled off by selecting a different P65E option for Aux1 AUX1 OUTPUT PULSE ON RADIO KEY AUX BUTTON When this option is on RK4 Radio Key s AUX button will PULSE the AUX1 output on for approx 2 seconds PROGRAMMING SEQUENCE P65E 4E turns the option ON The option is toggled off by selecting a different P65E option for Aux1 Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING AUX2 Output is on header J3 on the main board eXNV l er 8 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P59E AUX Zones PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON RELATED OPTIONS P69E 2E Arm2 output pulses PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES When this option is enabled the Radio Key s Panic button will no longer generate a Panic Alarm P66E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES When this option is enabled the Radio Key s Panic button will no longer generate a Panic Alarm PROGRAM MODE LEVE
19. Once programmed zones can accept both radio devices and normal zone inputs simultaneously The optional 100 200 Ness Radio Interface is required for radio devices to operate A radio device is any type of Ness transmitter including Radio PIR Radio Reed Switches Radio Smoke Detector PROGRAMMING RADIO DEVICES Up to 8 radio devices can be assigned to the ECO8x one per zone PROGRAMMING SEQUENCE NO RESTORALS Suitable for 100 663 R15 Radio PIR 100 691 R12 Radio PIR 100 683 Radio Pendant 100 203 Radio Smoke Detector Select a zone using PO1E POSE The ARMED light will be ON if a Radio Device is already programmed to the zone Press OE to delete O Press 1E The READY light will turn ON to indicate that the zone is ready to accept the Radio Device Trigger the Radio Device A If the Radio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound B If the READY light stays on and a warning beep sounds the Radio Device is already assigned to another zone and must be cleared from that zone first C If SUPERVISED SIGNALS have also been successfully recognised the TAMPER light will turn ON EXAMPLE To program a Radio PIR on zone 1 PO1E 1E Trigger the Radio PIR or simply connect the battery PROGRAMMING SEQUENCE WITH RESTORALS Suitable for 100 662 Radio Reed Switch Alarm the reed switch ie move the magnet away from the switch Leave the reed switch in the alarm condition
20. P76E Zone No E toggles the option ON and OFF Zone No E OFF Restoral reporting disabled for that zone Zone No E ON Restoral reporting enabled for that zone REPORT MULTIPLE ZONE ALARMS Zones selected for Multiple Zone Alarms will report each time the zone alarms and without a restore being sent The number of reports is a maximum of 15 The number of alarms sent for each Multiple Zone Alarm can be reduced to 3 by using the swinger shutdown option P89E 4E Zones not selected report only once until reset by an opening or a valid code PROGRAMMING SEQUENCE P78E Zone No E toggles the option ON and OFF Zone No E OFF Multiple Zone Alarms disabled for that zone Zone No E ON Multiple Zone Alarms enabled for that zone Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING ALARM RESTORAL Option No DEFAULT Option No DEFAULT P75E P92E Duress P75E 1E REPORT MISCELLANEOUS Medical P75E 2E ES KP Panic amp KS Panic P75E Installer Remote by PC Fire P75E 4E FACTORY DEFAULT Panel tamper PRE see table External tamper P75E 6E NOTES Keypad Tamper P75E 7E Radio Tamper P92E 1E REPORT MISCELLANEOUS RESTORALS Supervision fail PROGRAM MODE LEVEL Panel battery Installer Remote by PC Mains fail FACTORY DEFAULT not used see table not used REPORT MISCELLANEOUS ALARMS REPORT MISCELLANEOUS RESTORALS These options select which Mi
21. and program the Extra Options mE assigned when programming the code or at any time later 1 Select a User Code P201 P256E The Exclude light is OFF 2 Press EXCLUDE E 7he Exclude light turns ON This gives access to programming Extra Options for codes In NORMAL USER CODE PROGRAMMING mode Exclude light is off you can do the following 1E AREA 1 CODES Assign remove user codes to Area 1 By default all user codes are assigned to Area 1 B 2bE AREA 2 CODES Assign remove user codes to Area 2 View radio signal strength see page 47 User codes can be assigned to Area 1 Area 2 both areas no areas Area will not arm unless it has one or more zones assigned to it P45E P46E it a code is not assigned to any Area s the code can be used for special functions such as to trigger outputs 3E ARM ONLY User Codes 2 56 can be programmed to Arm but not Disarm the panel See page 12 4E CODE ONLY ARMING Enables selected user codes to allow code only arming Arming can then be done either with or without the use of the arm key on the keypad In the case of radio codes the radio key OFF button will toggle the armed state of the area assigned to the radio key it the User code is assigned to both AREA 1 and AREA 2 If AREA 1 is already armed then entering the code will disarm AREA 1 but arm AREA 2 If the intention is to either ARM or DISARM both areas using this code then ARM code must be used
22. first to arm both areas Once both are armed they can be disarmed if in Home mode then the action is to exit Home mode 5E RADIO CODE Enables selected user codes as Radio Codes for operation by Ness Radio Key or Radio Keypad Page 49 how to program Radio Codes Ness ECO8x PANEL INSTALLATION MANUAL 13 PROGRAMMING PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 20 seconds NOTES Programmable from 1 99 seconds PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 60 seconds NOTES Programmable from 1 99 seconds RELATED OPTIONS P62E 8E Exit Time x10 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5 minutes NOTES Programmable from 1 99 minutes Siren times of longer than 5 minutes are contrary to noise pollution regulations in most areas Option No Description Default Note P26E ENTRY DELAY TIME 20 seconds 28 EXIT DELAY TIME 60 seconds P29E SIREN RESET TIME 5 minutes ENTRY DELAY TIME The Entry Delay Time is the time given to disarm the panel after an Entry Delay zone is triggered The Entry Delay Time setting is from 1 to 99 seconds in 1 second increments PROGRAMMING SEQUENCE P26E existing time is displayed one digit at a time ENTER NEW TIME E new time is displayed one digit at a time EXAMPLE To program Entry Delay Time to be 30 seconds P26E 30E EXIT DELAY TIME Th
23. is automatically multiplied by 2 EXAMPLES A New Installation Set the time before the first test call E g If you are programming the panel at 5pm and you want test calls to be sent at lam Enter P84E 4 x 2 8hrs Therefore 5pm 8hrs 1am B Existing Installation To reset the time that test calls are sent E g Our example panel is sending test calls at 1am and you want to change it to 2am If you are programming the panel at 6pm enter P84E 4E 4 x 2 8hrs Therefore 8hrs 2 PROGRAMMING SEQUENCE Press P84E The existing Time Before First Test Call will be displayed See note 3 Press NEW TIME E The new Time Before First Test Call will be displayed S JE 2 2 o Bjal olal 2 2 5 Option No Description 1E 2E 4E 5E 6E 7E 8 P85E DIALLING METHOD ON DIALLING METHOD The dialler can be set to dial in PULSE Decadic or DTMF dialling or auto select depending on dial tone Factory default is DTMF dialling This option should not be changed for use in Australia New Zealand or Europe PROGRAMMING SEQUENCE P85E 1E 3E turns the option ON 1E ON Auto Select Dialling PULSE or DTMF 2E ON Pulse Dialling always 3E ON DTMF Dialling always Ness ECO8x PANEL INSTALLATION MANUAL P86E 1E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Dialler is enabled NOTES T
24. programmed to be Radio Codes as required NOTES 1 Keypad Codes beginning with 0 zero can be programmed but they will not operate the panel This is an alternative method for disabling user codes The MEMORY E function is recommended for deleting user codes 2 All codes must be unique to each other Codes are rejected if already used Some codes that are similar to existing codes may also be rejected PROGRAMMING KEYPAD CODES Press P 11 25 E The existing code is displayed one digit at a time Press NEW CODE E NEW CODE AGAIN E The new code is displayed Example To program the Master Code to be 1234 Press P11E 1234E beep 1234E beeps When re programming an existing keypad code the new code will overwrite the old code DELETING KEYPAD CODES To delete a User Code without programming a new code press the MEMORY key in place of the code Example To delete User Code 2 press P12E MEMORY OA keypad code only needs to be deleted if you re not replacing it with a new code ARM ONLY CODES Arm Only is an extra option for user codes See next page for further information User Codes 2 15 can optionally be programmed as Arm Only Codes which can Arm but cannot Disarm the panel Used for cleaners temporary staff etc Example To program User Code 2 to be 1234 and an Arm Only code Press P12E EXCLUDE E 3E EXCLUDE E 1234E 1234E EXCLUDE E enters Extra Options mode SE enables the Arm Only opt
25. used as Fail To Communicate output to trigger backup communications devices such as GSM The AUX output is automatically turned off on the next successful communication attempt or when the panel is next disarmed PROGRAMMING SEQUENCE P66E 6E turns the option ON The option is toggled off by selecting a different P66E option for Aux2 E o E o E E E D g S c S 5 5 8 Option No Description 1E 2E 4E 5E 6E 7E 8 P68E MISCELLANEOUS OPTIONS 1 3K3 ZONE RESISTORS Setting this option ON changes the Zones 1 8 monitoring resistor from 2K2 to PROGRAMMING SEQUENCE P68E 2E toggles the option ON and OFF OFF 3K3 zone resistors disabled ON 3K3 zone resistors enabled QUIET CHIRPS ON ARM DISARM When this option is enabled the Keyswitch Radio Key Arm Disarm amp Radio Key Home mode siren chirps are reduced in volume to a quiet chirp Arm Disarm or Home Chirps must be enabled PROGRAMMING SEQUENCE P68E 8E toggles the option ON and OFF OFF Quiet Chirps disabled ON Quiet Chirps enabled Ness ECO8x PANEL INSTALLATION MANUAL El PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES This does not affect the RESET output
26. 40E P42E RELATED OPTIONS P63E 1 4 Home Mode output mapping P64E 1E Brief Home Mode alarm P69E 3E Quiet Home Mode siren P69E 5E Home Mode by Radio Key ON OFF buttons P69E 7E Home Mode chirps P69E 8E Home Mode arm by Radio Key AUX button PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF NOTES When a zone is selected as 24hr it is automatically removed from both Areas When a 24hr zone is assigned to an Area P45E or P46E it is no longer a 24hr zone PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF RELATED OPTIONS P63E 5E 8E Day zone output mapping P64E 2E Brief Day Mode alarm IDEAS FOR DAY ZONE USE Instant alert for a delivery door Doorway alert for a shop Pool gate opened warning PROGRAMMING HOME MODE ZONES Home Mode zones allow you to Arm selected zones while others are ignored Typically used for perimeter zones such as windows and doors while you are at home For example upstairs zones are Disarmed while downstairs zones are Armed in Home mode PROGRAMMING SEQUENCE P51E Zone 1000 65 the options ON and OFF P51E Zone OFF The zone is not a Home zone P51E Zone No E ON The zone is a Home zone NOTE Zones selected to Report Zone Alarms P74E will by default report alarms in Home Mode if the dialler is enabled The Brief Home Alarm option P64E 1E when enabled prevents Home Mode alarms from reporting S
27. 7E 1E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P87E 4E Number of Dialling attempts P87E 2 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON P87E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON NOTES Sets the total number of dialling attempts E g If 4 dialling attempts is selected this means 2 attempts per telephone number RELATED OPTIONS P87E 1E Alternate dialling e c 2 S g Z w c 5 e Option No Description 1E 2E 3E 4E 5E 6E 7E 8 87 MISC DIALLING OPTIONS ON ON SPLIT DIAL PRIMARY SECONDARY PHONE NUMBERS This option selects the order in which Telephone numbers 1 amp 2 are dialled PROGRAMMING SEQUENCE P87E 1E toggles the option ON and OFF OFF Alternate Dial Dial Telephone No 1 on the first attempt If no answer dial Telephone No 2 Continue alternating until successful ON Split Dial Dial Telephone No 1 for half of the call attempts If unsuccessful dial Telephone No 2 for the last half of call attempts CHECK FOR DIAL TONE The dialler can be programmed to check for a dial tone before dialling The dialler will still dial out if a dial tone is not detected but this means several seconds will have elapsed Allows use on with non standard dial tones PROGRAMMING SEQUENCE P87E 2E toggles the option ON an
28. E Vibration EKTREME z e P32E Vibration HIGHEST 6 Vibration HIGH z P34E Vibration MEDIUM ES P35E Vibration LOWER gt P36E Vibration LOWEST P37E 1 second ZONES P38E 3 second ZONES Extreme sensitivity P31E should not be used It is provided as a guide only Ness NESSENSOR Vibration Sensor Part No VIB100 In addition to zone sensitivity adjustment the overall sensitivity of the Nesssensor can be adjusted by rotating the body of the Nesssensor within its bracket 9 9 6 Dg N C Vibration bee BLES contacts YELLOW 20mm I S N C Tamper GREEN Sloop i i H 350mm cable 4 pep rum bg 36mm 2 holes at 27mm spacing Cad 2A The Nessensor bracket must always be mounted horizontally and the arrow must point up for any required setting LONG RESPONSE ZONES Long Response Zones are normal alarm zones with a long reaction time Individual zones can be programmed to have either a 1 second response P37E or 3 second response P38E PROGRAMMING SEQUENCE P37E or P38E Zone No E 000 65 zones ON and OFF Ness ECO8x PANEL INSTALLATION MANUAL 15 PROGRAMMING ZONE DELAY TYPES Only one option per zone can be selected For example a zone cannot be instant and delayed at the same PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF NOTES Dou
29. EL INSTALLATION MANUAL NO BEA 99 6 PROGRAMMING PROGRAM MODE LEVELS TABLE 4 FLOW CHART Power up with Program Link OFF Usually on first time installation INSTALLER PROGRAM Mode PROGRAM LIGHT IS FLASHING CP INSTALLER CODE Factory default Installer Code 000000 USER PROGRAM Mode PROGRAM LIGHT IS ON P MASTER CODE E Factory default Master Code 123 NORMAL OPERATING Mode PROGRAM LIGHT IS OFF HOW TO ENTER PROGRAM MODE FROM POWER UP 1 Power up with the PROG link OFF The PROG link or Box Tamper lead must be ON in Operating Mode OR USING THE KEYPAD The panel must be disarmed 1 Press Master Code E This is User Program Mode PROGRAM light is ON 2 Press INSTALLER Cope E This is Installer Program Mode PROGRAM light is FLASHING HOW TO EXIT PROGRAM MODE 1 Press E Exits directly to Operating Mode PROGRAM light is OFF PROGRAMMING PO8E PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT User Code 1 123 All other codes blank NOTES 1 To clear all codes except the Installer Code enter P98E in Installer Program mode This also defaults user code 1 to 123 See Page 45 2 Open Close reports are identified by user number when the control panel is base station monitored RELATED OPTIONS Installer Code See Page 11 How To Enter Program Mode Page 45 P
30. EL Installer Remote by PC FACTORY DEFAULT All zones report Alarms NOTES OE will turn all selections OFF MEMORY E will turn all selections ON P76E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All zones report Restorals NOTES OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P82E 1E Send Restoral immediately P82E 2E Send Restoral after siren time P82E SE Send Restoral on Disarm amp Seal P82E 4E Send Restoral on Disarm always P78E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF No zones report Multiple Alarms NOTES OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P89E 4E Swinger shutdown ZONES Option No Description 12345678 P74E REPORT ZONE ALARMS ON ON ON ON ON ON ON ON P76E REPORT ZONE RESTORALS ON ON ON ON ON ON ON P78bE MULTIPLE ZONE ALARMS REPORT ZONE ALARMS This option selects which zone inputs will send Alarm reports to the Central Station PROGRAMMING SEQUENCE P74E Zone No E toggles the option ON and OFF Zone No E OFF Alarm reporting disabled for that zone Zone No E ON Alarm reporting enabled for that zone REPORT ZONE RESTORALS This option selects which zone inputs will send Restoral reports to the Central Station Only zones that have previously sent an Alarm will send a Restoral PROGRAMMING SEQUENCE
31. EL Installer Remote by PC FACTORY DEFAULT ON RELATED OPTIONS P88E 8E Auto Exclude Reports P88E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON RELATED OPTIONS P88E 7E Manual Exclude Reports PROGRAMMING m AREA open close report AREA2 open close report Manual exclude report Auto exclude report m N m Option No Description 3E 4E 6E g 1 Forced opening report o z z P88E OPEN CLOSE REPORTING OPTIONS AREA1 OPEN CLOSE REPORTS Enables or disables sending of AREA1 Open Close reports The User ID of the code used is included in the report Keyswitch arming is identified as User 16 Shortcut arming is identified as User 17 PROGRAMMING SEQUENCE P88E 1E toggles the option ON and OFF OFF No AREA1 Open Close reports ON AREA1 Open Close reports enabled AREA2 OPEN CLOSE REPORTS Enables or disables sending of AREA2 Open Close reports PROGRAMMING SEQUENCE P88E 2E toggles the option ON and OFF OFF No AREA2 Open Close reports ON AREA2 Open Close reports enabled FORCED OPENING REPORT If Forced Opening Report is selected ON when an alarm has been reset by a valid User Code or Radio Key the dialler will send an Opening report along with a restoral report for the zone or miscellaneous input which caused the alarm PROGRAMMING SEQUENCE P88E 5E toggles the option ON and OFF OFF No Forced opening Reports ON Forced ope
32. ELATED OPTIONS PROGRAMMING SEQUENCE P62E 7E Siren burst on Auto Exclude P60E GE toggles the option ON and OFF OFF Auto Exclude disabled instant alarm if unsealed at end of Exit Time ON Auto Exclude enabled zone is excluded if unsealed at end of Exit Time P60E 7E DISABLE THE DISPLAY PROGRAM MODE LEVEL The LED indicators on the keypad can be programmed to blank after 4 minutes of no Installer Remote by PC keypad use Any action that causes a beep will restore the display or press the E key to restore the display FACTORY DEFAULT OFF PROGRAMMING SEQUENCE P60E 7E toggles the option ON and OFF NOTES get The display LEDs will turn off but the key OFF Display is always on backlighting will remain ON Display will blank after 4 minutes Ness ECO8x PANEL INSTALLATION MANUAL E3 PROGRAMMING Tamper to keypad SONALERT KP Panic to RESET output m KP Panic to keypad SONALERT m Tamper to RESET output n Tamper to STROBE output i Tamper to SIREN output Option No Description KP Panic to STROBE output 2 9 2 KP Panic to SIREN output P61E TAMPER amp PANIC ALARM MAPPING ON ON ON ON o z a HAN TAMPER ALARM OUTPUT MAPPING PROGRAM MODE LEVEL This option selects which outputs will trigger when a Tamper Alarm occurs Installer Remote by PC PROGRAMMING SEQUENCE o P61E 1E 4E toggles the options ON and OFF 1E ON
33. L Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P89E 5E Line Fail Monitor AUX2 Toggle on Radio Key PANIC Button im AUX2 Pulse on Radio Key PANIC Button AUX2 is Fail To Communicate output m AUX2 is Zone Alarm output AUX2 is Line Fail output Option No Description 7E 8E AUX2 is Area2 armed output P66E AUX2 OUTPUT OPTIONS Select one output type for AUX2 AUX2 OUTPUT ZONE ALARM When this option is on zones selected in P59E will turn on AUX2 when they go into alarm The AUX2 output stays on until the panel is disarmed PROGRAMMING SEQUENCE P66E 1E turns the option ON The option is toggled off by selecting a different P66E option for Aux2 AUX2 OUTPUT AREA2 ARMED OUTPUT When this option is enabled the AUX2 output turns on when Area2 is armed and turns off when the panel is disarmed The output can be optionally programmed to output a momentary pulse on arming see P69E 2E PROGRAMMING SEQUENCE P66E 2E turns the option ON The option is toggled off by selecting a different P66E option for Aux2 AUX2 OUTPUT TOGGLE ON RADIO KEY PANIC BUTTON When this option is on RK4 Radio Key s PANIC button will TOGGLE the AUX2 output The output will operate independently of the panel s armed status ie disarming does not turn Aux2 off PROGRAMMING SEQUENCE P66E turns the option ON The option is toggled off by selecting a different P66E optio
34. LN Enter your new PIN code again The new code will be displayed on the keypad one digit at a time 5 PE To exit program mode Program light will turn off QUICK START 2 STEP KEYSTROKES DESCRIPTION COMMENT 1 P123E Enters User Program Mode Program light will turn on P000000E Enters Installer Program Mode Program light will flash P11E Selects the option for User Code 1 The existing code will be displayed on the keypad one digit at a time 4 27 Enter your PIN code followed codes 6 digits by E in length 5 uuu Enter your new PIN code again The new code will be displayed on the keypad one digit at a time P86E4E Turns on option P86E 4E Enables Audible Monitoring P70E Selects the option for Telephone The existing number will be displayed on Number 1 the keypad one digit at a time 8 E Enter the telephone number The new number will be displayed on the followed by E max 30 digits keypad one digit at a time 9 PE To exit program mode Program light will turn off QUICK START 3 STEP KEYSTROKES DESCRIPTION COMMENT 1 P123E Enters User Program Mode Program light will turn on P000000 E Enters Installer Program Mode Program light will flash P11E Selects the option for User Code 1 The existing code will be displayed on the keypad one digit at a time 4 ____ Enter your
35. Mains Report Delay 1 hour Listen In to Dialler Swinger shutdown Line Fault Monitor Use Internal Timing Enable Remote Access Enable Remote Event Report Enable Callback Mode Quiet Home Mode Siren Home Mode by Radio Key ON OFF buttons Disable Mains Fail Alarm Home Mode chirps Radio Key arm Home Mode by Radio Key AUX button TELEPHONE No 1 Primary NONE Telephone No 2 Secondary ACCOUNT No 1 NONE 0000 P92bE Report Misc Alarms 9 14 1E 2E 3E 4E 5E 6E Reguired rings to answer Report RADIO TAMPER Report RADIO PANIC by User ID Report RADIO LOW BATTERY by device Report ZONE SUPERVISION FAIL Report PANEL LOW BATTERY Report MAINS FAIL Report Misc Restorals 9 14 CLEAR RADIO DEVICES P75E 1E Report 2 Misc Alarms 3E 1 8 4E 5E 6E 7E 8E REPORT ZONE ALARMS Report DURESS alarms All zones CLEAR MEMORY CLEAR PANEL OPTIONS restore Factory Defaults Report MEDICAL alarms Report keypad amp Keyswitch PANIC Report FIRE alarms CLEAR User codes and Radio Keys Program the INSTALLER CODE Real Time Clock set MINUTES 000000 Report PANEL TAMPER alarms P131E Real Time Clock set HOURS Report EXTERNAL TAMPER alarms P132bE Real Time Clock set DAY Report KEYPAD TAMPER alarms P133E Real Time Clock set MONTH Report EXIT FROM INSTALLER mode
36. Multiple Zone Alarms RELATED OPTIONS P78E Report Multiple Zone Alarms P89E 5E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P66E 5E 2 is Line Fail Output P89E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF PROGRAMMING SWINGER SHUTDOWN Limits the number of calls made by a zone alarm any one armed period Alarm reports are normally limited to 15 multiple reports per zone When Swinger Shutdown is enabled multiple reports are reduced to 3 multiple reports per zone PROGRAMMING SEQUENCE P89E toggles the option ON and OFF OFF Swinger Shutdown is 15 reports per zone ON Swinger Shutdown is 3 reports per zone LINE FAIL MONITOR This option enables the Line Fail monitor which periodically 20secs tests the telephone line If the telephone line is not found the Line light starts flashing If the line fault continues for 2 minutes then the keypad beeps a warning and Aux2 is turned ON if that option is selected PROGRAMMING SEQUENCE P89E 5E toggles the option ON and OFF OFF No Line Fail Monitor ON Line Fault Monitor enabled INTERNAL TIMING When set ON the Test Report Timer uses the panel s onboard crystal oscillator instead of the external mains power supply frequency Use this option if the mains frequency is not stable over long periods Not necessary in Australia and New Zealand PROGRAMMING SEQUENCE P89E 7E toggles the
37. Ness 8 ALARM CONTROL PANEL INSTALLATION amp PROGRAMMING MANUAL Revision 1 5 A 15 00 Australia s largest designer and manufacturer of high guality security products MADEX AUSTRALIA wa Quality Endorsed Company 1509001 LIC No QEC2074 NSW Head Office only Security Products WWW Ress Con atu Head Office Ness Security Products Pty Ltd ABN 28 069 984 372 Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au NSW Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au VIC Ph 03 9875 6400 Fax 03 9875 6422 nessmelb ness com au QLD Ph 07 3399 4910 Fax 07 3217 9711 nessbris ness com au WA Ph 08 9328 2511 Fax 08 9227 7073 nessper ness com au SA Ph 08 8152 0000 Fax 08 8152 0100 adelaide ness com au CONTENTS Installation notes tereti ntn repente petiere id nen rk Ene reip 4 Input and output descriptions seese e 5 CONNECTION DIAGRAM DEVICES 6 7 AYA oa Ya EE 8 OPERATION Operation SUMMA ert e et Pr uds 9 HOW TO PROGRAM Quick start 0 10 How to enter Program Mode 11 GENERAL OPTIONS User Codes nne AAA AAA AAA 12 13 UICE EET 14 Vibration Sensitivity a s ABA WEKA sua 15 2 16 17 19 e ep pete tege mede ed 17 Definitions Day
38. ON Press the Radio Key OFF button twice within 5 seconds Press the Radio Key ON button twice within 5 seconds See page 18 for Home Mode operation DISABLE MAINS FAIL ALARM When this option is enabled a Mains Fail alarm is Not displayed on the keypad Does not give warning beeps s not saved to MEMORY and the MEMORY display does not flash PROGRAMMING SEQUENCE P69E GE toggles the option ON and OFF OFF Mains Fail alarm operates normally ON Mains Fail alarm is disabled HOME MODE CHIRPS Allows 2 siren chirps when Home Mode arming with a Radio Key Note that the Siren Chirps can be made quieter with the P68E 8E option PROGRAMMING SEQUENCE P69E 6E 000 65 the option ON and OFF OFF Mains Fail alarm operates normally ON Mains Fail alarm is disabled HOME ARM BY RADIO KEY AUX BUTTON This option enables the AUX button on a Ness RK4 Radio Key to arm Home Mode This option is independent of P69E 5E Home Mode arming by radio key ON OFF buttons OFF Home Mode Arm by Radio Key AUX disabled ON Home Mode Arm by Radio Key AUX enabled Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING P70E P71E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT None NOTES If telephone number 2 is disabled all calls are made on telephone number 1 and the setting of P87E 1E has no effect When programming any keypress will interrupt the telephone number display seq
39. ORM OF Duress ssss18 1 121 01 030 k sess Apcount Number Keyswitch Panic 555518 1 120 01 031 k 0 d or Open Keypad Panic ssss 18 1 1120 01 032 k 3 Restore or Close Radio Key Panic 555518 1 120 01 1dd k XYZ Alarm type Medical Alarm ssss 18 1 100 01 033 k GG Group or Area designation Fire ssss18 1 110 01 034 k CCC Alarm number Exit Install mode ssss 18 1 306 01 035 k Internal Tamper ssss 18 q 137 01 041 k dd User ID 1 to 15 Keypad Tamper ssss18 q 137 01 042 k zz Zo e ID 1 19 8 Radio Sensor Tamper ssss18 q 383 01 277 k MESE Radio Sensor Low Battery ssss18 384 01 377 k aa 0208 Mains Fail ssss18 31 050 k Panel Battery Fail 555518 q 309 01 051 k aa 00 24 Hr Area K Checksum 0 to Of hex Open 555518 1 402 aa Odd k Force Open Cancel 555 18 1 406 aa Odd k Close ssss 18 3 402 aa Odd k Test Report 555518 1 602 01 063 k Zone 1 8 Manual Exclude ssss18 573 aa 001 008 k Zone 1 8 Auto Exclude ssss18 q 380 aa 001 008 k Keyswitch arming is identified as User 16 Shortcut arming is identified as User 17 52 Ness ECO8x PANEL INSTALLATION MANUAL AUDIBLE MONITORING APPEL TELEPHONE LINE ANY TELEPHONE 1 MONITORED PREMISES AUDIBLE MONITORING REPORTING FORMAT TABLE Digit Digit A B Alarm Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Duress Keyswitch Tamper Panic Keypad Panic Radio Panic
40. Press P25E OE Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC NOTES These options are dynamically updated When the program option is entered the keypad display will show the current value Option No Description Default Note P130E REAL TIME CLOCK SET MINUTES 00 00 59 minutes 1 1 REAL TIME CLOCK SET HOURS 00 00 23 hours 00 midnight P132E REAL TIME CLOCK SET DAY 01 01 31 days P133E REAL TIME CLOCK SET MONTH 01 01 12 months P134E REAL TIME CLOCK SET YEAR 06 00 63 2000 2063 P135E REAL TIME CLOCK SET DAY OF WEEK 1 1 7 1 Sunday 7 Saturday REAL TIME CLOCK PROGRAMMING This is used to record the time and date of events to the Event Memory which can accessed by remote connection using NessComms software P130E Real Time Clock MINUTES Enter a value between 00 and 59 Default 00 minutes P131E Real Time Clock HOURS Enter a value between 00 and 23 Default 00 hours P132E Real Time Clock DAY OF THE MONTH Enter a value between 01 and 31 Default 01 1st day of the month Ensure that the setting does not exceed the days in the current month The panel does not cross check this setting P133E Real Time Clock MONTH Enter a value between 01 and 12 Default 01 January P134E Real Time Clock YEAR Enter a value between 00 and 63 2000 2063 Default 06 2006 P135E Real Time Clock DAY OF THE WEEK Enter a val
41. SORS Nessensors are sensitive to high frequencies and insensitive to low frequencies Therefore it is not necessary to apply much force to the protected structure rather a very rapid succession of blows The sensitivity has been correctly adjusted when a single blow applied with a soft object e g by hand does not cause an alarm whereas a rapid series of blows using a metal object such as a screwdriver blade will cause an alarm P37E P38E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all off NOTES A Long Response Zone cannot be Normal Zone or Vibration zone at the same time To convert zone s back to a Normal Zone turn on the required zone s at PSOE PROGRAMMING VIBRATION SENSITIVITY Each zone has individually adjustable sensitivity for connection of Nessensor Vibration Sensors Zone sensitivity is adjusted by toggling zones ON in options P30E to P36E P30E is Normal Sensitivity vibration analyser disabled This is used for normal alarm devices Zone response time 200ms P31 36E are the options for the 6 levels of vibration sensitivities P31E is the most sensitive setting PROGRAMMING SEQUENCE P 30 38 E zones are displayed Zone No E EXAMPLE To program zones 2 and 3 to be Medium sensitivity P34E 2E the keypad display will show zone lights 2 amp 3 on ZONES OptionNo Description 123 4 5 6 7 8 P30E NORMAL ON ON ON ON ON ON ON ON AA P31
42. TALLATION MANUAL PROGRAM MODE LEVEL Installer FACTORY DEFAULT No Radio Codes all code are keypad codes NOTES User Code 1 Master Code is always a Keypad Code Radio Codes can be deleted by keypad in the case of a lost Radio Key Radio Keys are assigned to User Codes so that Open Close reports are identified by user number when the control panel is base station monitored If Open Close reports are enabled RELATED OPTIONS PO1E POS8E Programming Radio Devices P64E 4E Radio Key Siren Chirps P68E 8E Quiet Chirps on radio arming P69E 5E Home arm by radio key ON OFF buttons EXTRA OPTIONS MODE Exclude Light is on 5E RADIO CODE USER CODE OPTIONS TABLE OPTION USER CODE NO P11E P12E P13E NESS RADIO A 100 664 100 067 ce GO 100 001 Ness RK3 Ness RK4 2 2 Ness 2 Radio Key Radio Key 22 Radio Keypad RADIO CODES Each of the 15 User Codes except for the Master Code can be programmed to be a Radio Codes This allows up to 14 Ness Radio Keys to be used for Arming and Disarming of the panel The Ness RKP Radio Keypad can also be used see the manual for programming details The optional 100 200 Ness Radio Interface is required for radio operation PROGRAMMING RADIO KEYS Use the Extra Options programming mode to enable selected user codes as Radio Codes When a user code is enabled as a Radio
43. TORY DEFAULT 6 12hrs NOTES 1 Enter a value from 1 to 99 2 If Test Calls are to start immediately then the value is set to 0 3 The Time Before Next Test Call is constantly updated When viewed the current value will be displayed not the initially entered value RELATED OPTIONS P89E 1E Enable Test Calls P83E Test Call interval PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 3E ON DTMF Dialling always NOTES Only one option is allowed to be ON THE DECADIC OR PULSE DIALLING ON THIS DEVICE IS UNSUITABLE FOR USE ON THE TELECOM NETWORK IN NEW ZEALAND Option No Description Default Note P83E TEST CALL INTERVAL 84 x2 168hrs P84E TIME BEFORE FIRST TEST CALL 6 x2 12hrs TEST CALL INTERVAL Test calls to the Central Station can be sent at intervals between 2 and 198 hours in 2 hour increments Programmable from 2 to 198 Hours Enter a value between 1 and 99 This is automatically multiplied by 2 Test Calls must be enabled by option P89E 1E PROGRAMMING SEQUENCE Press P83E The existing Test Call Interval time will be displayed Press NEW TIME E The new Test Call Interval time will be displayed EXAMPLE To program daily test calls Press P83E12E TIME BEFORE FIRST TEST CALL This option sets the time before the first Test Call and is used to set the preferred time for Test Calls Programmable from 2 to 198 Hours Enter a value between 1 and 99 This
44. TPUT ZONES Selects the zones to trigger the Reset output PROGRAMMING SEGUENCE P54E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the Reset output Zone No ON The zone will trigger the Reset output STROBE OUTPUT ZONES Selects the zones to trigger the Strobe output PROGRAMMING SEQUENCE P55E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the Strobe output Zone No ON The zone will trigger the Strobe output KEYPAD SONALERT ZONES Selects the zones which will sound the Keypad Sonalert beeper PROGRAMMING SEQUENCE P56E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the Keypad Sonalert Zone No ON The zone will trigger the Keypad Sonalert gJ Ness ECO8x PANEL INSTALLATION MANUAL P57E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All ON PROGRAMMING SHORTCUTS Use 0E to turn all selections OFF Use MEMORY E to turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF PROGRAMMING SHORTCUTS Use OE to turn all selections OFF Use MEMORY E to turn all selections ON RELATED OPTIONS P66E 1E Aux2 Zone Alarm Output PROGRAMMING SIREN OUTPUT ZONES Selects the zones to trigger the Siren output PROGRAMMING SEQUENCE P57E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the Siren output Zone
45. Test Calls ON Test Calls enabled MAINS REPORT DELAY This option allows Mains Fail reports to be delayed by one hour if the mains power has been off continuously for that time This avoids mains fail reports being sent to the Central Station in the event of brief power failures PROGRAMMING SEQUENCE P89E 2E toggles the option ON and OFF OFF Mains Fail reports immediately ON Mains Fail report is delayed by 1 hour LISTEN IN TO DIALLER This is a diagnostic feature to allow the installer to hear the dialler message and other telephone tones through a horn speaker To operate enable option P89E 3E Listen In is enabled for a minimum of 4 minutes after exiting Program Mode During Listen In the dialler message and other telephone tones can be heard through the Siren output at low volume while the dialler is sending reports The 4 minute period is restarted whenever any key on the keypad is pressed To turn Listen In off go back into Installer Program mode and toggle the option OFF PROGRAMMING SEQUENCE P89E 000 65 the option ON and OFF OFF Listen In disabled ON Listen In enabled 42 Ness ECO8x PANEL INSTALLATION MANUAL P89E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON NOTES This prevents unnecessary multiple alarms reported to the Central station in cases for example where a door is swinging in the wind This option only applies to zones enabled to Report
46. Y These terminals are for the connection of a sealed lead acid rechargeable 12 Volt battery Charge current is limited to 350mA The charge voltage is factory preset at 13 8V and does not need changing Note A 12 Volt sealed lead acid rechargeable battery must be connected for correct panel operation Observe correct polarity when connecting the battery Ness Part Number BAT210 12V 7Ah battery EARTH For maximum protection against damage caused by lightning strikes connect a good earth to this terminal Alternatively use the Earth lead from the plug pack PROG TAMP Program Link amp Internal Tamper Input The PROG TAMP link has two purposes 1 To enter Installer Program Mode on initial power up Power up with the PROG link OFF The PROG link or Box Tamper lead must be ON in operating mode 2 Box Tamper When used with the Internal Tamper Lead supplied PROG TAMP serves as the 24hr tamper input for the panel s internal tamper switch This circuit should not be wired external to the box Replace the PROG Link with the Box Tamper Lead Connect the Internal Tamper Lead spade terminals directly to the terminals of the internal tamper switch supplied An end of line resistor is NOT required on this input When PROG TAMP is used for Internal Tamper powering up with the panel s cover open will enter Installer Program Mode OUTPUTS 12 VOLT OUTPUT A regulated 13 8 VDC output is available to power detectors and other eq
47. Zones Temp Day Zones Home 18 Zone To Output 20 21 Various Options ie nene Let dee soi det ede tbt 22 23 Tamper Keypad Panic Output Mapping 24 System Operation Shortcuts 25 Home mode output mapping eeeme 26 Day mode output mapping eee 26 Miscellaneous Options sse 27 28 Aux1 Output aa ka Ai decer to re and 29 Aux2 Output Options ccr teri d redet Len 30 Mise re eni ee E 31 33 TELEPHONE NUMBERS sese 34 Account e etae eL dh eh E Eee 35 Alarm reporting options tentent tareas 36 37 Test Call Options e re orat 38 Dialler format eem 39 44 RESET FACTORY DEFAULTS ilaa 45 SPECIAL INSTALLER FUNCTIONS Send test report un noe ERR E 46 Siren test Panel reset Display software version RADIO OPTIONS 5 11 2 eee tree 47 Signal strength test Ness Radio Interface connection RADIO DEVICE PROGRAMMING 48 RADIO KEY 49 Real Time Clock options 50 MONITORING OPERATION Monitoring operation Contact ID 52 Audible MonitOrlng
48. and wait until radio transmission has stopped Select a zone using PO1E PO8E The ARMED light will be ON if a Radio Device is already programmed to the zone Press OE to delete e Press 1E The READY light will turn to indicate that the zone is ready accept the Radio Device Restore the reed switch place the magnet next to the switch A If the Radio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound B The MEMORY light will turn on to indicate that this device sends Restorals C If the READY light stays on and a warning beep sounds the Radio Device is already assigned to another zone and must be cleared from that zone first D If SUPERVISED SIGNALS have also been successfully recognised the TAMPER light will turn ON EXAMPLE To program a Radio Reed Switch with Restorals on zone 2 Alarm the reed switch PO2E 1E Restore the reed switch DELETING A RADIO DEVICE Use to POSE to select the zone Press OE to clear the device 3 beeps will sound timer allowing the detector to be walk tested without waiting for the 4 minute re transmit timer to expire If the TEST link is left on the PIR will automatically revert to normal mode after 30 minutes The Ness 12 and R15 Radio PIRs have TEST link which disables the re transmit TEST mode can be re started by briefly removing then replacing the battery 48 Ness ECO8x PANEL INS
49. be armed in HOME Mode if Area2 is already armed on these condi tions Area 1 must be OFF Area 2 must be armed first and then Home armed not the reverse Zones assigned to both Home mode P51E and to Area 2 P46E will act as Home zones when both Area 2 and Home are armed Zones must be assigned to P51E to allow Home arm Note Home arming when AREA 2 is armed cannot be done by Radio Key double OFF button or by keyswitch Note Home Mode is not available when Area 1 is armed or deselect zones to be Temporary Day Zones The selected zones are indicated by the corresponding zone number Permanent Day Zones set by installer option P53E are not displayed in selection mode Permanent Day Zones can be selected as Temporary Day Zones but this has no effect as those zones are already day zones E Saves changes and returns to normal operating mode DAE Enables and Disables Day Mode This enables disables both Temporary and Permanent Day Zones INDICATION The HOME light flashes continuously when Temporary Day Mode is enabled OUTPUTS When Day Mode is enabled any unsealed day zone will sound the programmed output for 2 seconds When Day Mode is disabled an unsealed day zone will simply be indicated on the keypad as an unsealed zone HOME MODE Home Mode allows selected zones to be armed whilst the system is disarmed For example this is often used to arm door and windows sensors overnigh
50. ble Trigger is useful for preventing unwanted alarms from zones in harsh environments such as sheds and garages PROGRAMMING SHORTCUTS Use OE to turn all selections OFF Use MEMORY E to turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Zones 3 8 are Instant NOTES When a zone is selected for this type it is automatically deselected from any other delay type PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Zone 1 NOTES The keypad sonalert will beep during Entry Delay as a reminder to disarm the panel Entry beeps can be disabled by program option P60E 1E When a zone is selected for this type it is automatically deselected from any other delay type ZONES Option No Description 12 3 4 5 6 7 8 P39E DOUBLE TRIGGER zones P40E INSTANT zones ON ON ON ON PA1E ENTRY DELAY 1 zones ON 42 HANDOVER zones ON P44E LOCKOUT zones Reset O P ONJ ON ON ON ON ON ON ON P45E AREA 1 zones ON ON ON ON ON ON ON ON P46E AREA 2 zones HOME zones P52E 24HR zones P53E DAY zones DOUBLE TRIGGER ZONES Zones programmed to Double Trigger will recognise an alarm condition if The zone has been triggered twice within a 4 minute period e f any 2 zones both programmed for double trigger each trigger once The zone is left unsealed for longer than 15 seconds PROGRAMMING SEQUENCE P39E Zone No E t
51. ce can operate on any zone along with the hardwired zone input if necessary Hardwired zones continue to operate as normal This would be the same as wiring two PIRs in series to one zone Radio Keys can also operate on radio zones for special purposes butthey should normally be programmed to a user code KEYSWITCH INPUT A Radio Device pro grammed to Zone 8 will still work as an alarm even if the Zone 8 input operation has been changed to Keyswitch operation The P60E 3E option only affects the Zone 8 terminal inputs VIBRATION Radio device zone signals IGNORE the P30E P38E vibration sensor settings TAMPER REPORT Radio Device Tamper operation depends on the Armed State of the control panel RADIO TAMPER causes the keypad to continuously beep and also to flash the RADIO TAMPER and the ZONE identifying the detector lights Pressing any key on the keypad or sending a TAMPER RESTORE will clear this warning LOW BATTERY REPORT A low battery gives 10 beeps and flashes the RADIO amp the BATTERY light The ZONE light identifying the radio device is also ON The flashing lights stop when any key on the keypad is pressed or a detector code with no low battery is received Low Battery generates HISTORY and DIALLER reports ONCE only until the low battery is fixed and a restore report is received NOTES Signal strength of Radio Keys can be tested in USER PROGRAM Mode or INSTALLER PROGRAM Mode Signal strength of a
52. d OFF OFF Dial without dial tone ON Dial only with dial tone 4 DIALLING ATTEMPTS Sets the number of dialling attempts when sending reports OFF sets a maximum 10 dial attempts before a 5 minute sleep and 10 more re tries if unsuccessful ON allows a maximum of 4 dial attempts before a 5 minute sleep and 4 more retries if unsuccessful If all attempts fail the dialler waits for the next trigger event The previously unsuccessful report will be included in the new message When sending Test Calls the time between dialling attempts increases to 60 minutes for the second round of dialling If a Test Call is unsuccessful after the first round of calls are made another call is made after 5 minutes If this call fails then subsequent calls are made every hour up to the maximum number of calls PROGRAMMING SEQUENCE P87E 4E toggles the option ON and OFF OFF Maximum 10 dialling attempts ON Maximum 4 dialling attempts Ness ECO8x PANEL INSTALLATION MANUAL P88E 1E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF P88E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF P88E 5E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON NOTES This option is used to indicate to the Central Station that an alarm has been reset valid user Usually used in cases where Open Close reports are normally not sent P88E 7E PROGRAM MODE LEV
53. d to operate with or without a User Code Installer Remote by PC PROGRAMMING SEQUENCE FACTORY DEFAULT P62E 1E 6E toggles the options ON and OFF EE cim 1E ON Memory Display shortcut 3E ON 2E ON Zone Exclude shortcut 4E OFF 3E ON Home Mode shortcut BE ON 4E ON Shortcut Smoke Output Reset on AUX1 If AUX 1 is set up to be SMOKE DETECTOR power E OFF output then it is activated by pressing 1 E AUX1 then turns OFF for 5 secs 5E ON 1 Arming shortcut NOTES 6E ON Area2 Arming shortcut Allocate a user code to Area2 before programming Area2 shortcut arming If Area2 is armed with the shortcut and a user OPERATING EXAMPLES code is not assigned to Area2 then you will not be able to disarm the panel Arming without shortcut User Cope Arming with shortcut P62E 7E SIREN BURST ON AUTO EKCLUDE PROGRAM MODE LEVEL This option enables the 2 second siren burst at the end of Exit Time to indicate that a Installer Remote by PC zone s has been Auto Excluded This does not apply to manually excluded zones FACTORY DEFAULT PROGRAMMING SEQUENCE ON P62E 7E toggles the option ON and OFF RELATED OPTIONS OFF Siren burst on Auto Exclude disabled P6OE 6E Auto Exclude zones ON Siren burst on Auto Exclude enabled P62b 8E EXIT TIME X10 PROGRAM MODE LEVEL This option multiplies the normal exit time by a factor of 10 Installer Remote by PG PROGRAMMING SEQUENCE FACTORY DEFAULT P62E 8E toggles
54. e 18 for more information on Temporary Day Zones Press O E To enable disable TDZ operation The HOME light flashes continuously when Day Mode is enabled Ness ECO8x PANEL INSTALLATION MANUAL 9 PROGRAMMING QUICK START 1 LOCAL SYSTEM Quick Start 1 shows you how to change User Code 1 the Master Code QUICK START 2 AUDIBLE MONITORING Quick Start 2 shows you how to change User Code 1 the Master Code enable Audible Monitoring and program a telephone number This will enable the dialler to report alarms to any telephone including mobile phones QUICK START 3 CENTRAL STATION MONITORING Quick Start 3 shows you how to change User Code 1 the Master Code enable Central Station Monitoring and program one telephone number This will enable the dialler to report alarms to a Central Station Default Master Code is 123 Default Installer Code is 000000 QUICK START PROGRAMMING Use one of these programming summaries for fast setup of your Ness ECO8x control panel as a Local Audible Monitored or Central Station Monitored system QUICK START 1 STEP KEYSTROKES DESCRIPTION COMMENT 1 P123E Enters User Program Mode Program light will turn on 2 P11E Selects the option for User Code 1 The existing code will be displayed on the keypad one digit at a time 3 Enter your new PIN code followed Keypad codes can be to 6 digits by E in length 4
55. e Exit Delay Time is the time given to secure and depart the premises after the panel is armed All zones in the Area being armed except 24hr zones are inactive during the Exit Delay time The Exit Delay Time setting is from 1 to 99 seconds in 1 second increments PROGRAMMING SEQUENCE P28E existing time is displayed one digit at a time ENTER NEW TIME E new time is displayed one digit at a time EXAMPLE To program Exit Delay to be 85 seconds P28E 85E SIREN RESET TIME The Siren Reset Time sets the duration of the Siren and Reset outputs The Siren Reset Time setting is from 1 to 99 minutes in 1 minute increments PROGRAMMING SEQUENCE P29E existing time is displayed one digit at a time ENTER NEW TIME E new time is displayed one digit at a time EXAMPLE To program Siren Time to be 4 minutes P29E 4E 14 Ness ECO8x PANEL INSTALLATION MANUAL P30E P36E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Normal sensitivity all zones ON NOTES Sensitivity can be individually programmed for each zone Zones are allocated to one sensitivity level at any one time Turning a zone ON in a sensitivity level turns the zone OFF in any other sensitivity level To revert zone sensitivity back to Normal turn on the required zone s at Sensitivity Level P31E is provided as a guide to the upper limit and should NOT BE USED o ADJUSTING NESSEN
56. e circuit board terminal blocks as per the wiring instructions shown in this installation manual 8 Replace the battery 9 Insert the panel tamper bracket as shown below 10 Close the lid and program the panel as required o 9 om NESS EB04 ENHANCED HOUSING s Removable lid Clip this side first then secure the lid with Screws provided Backup battery holder Fits up to 12V 7Ah battery Secure and easy to fit standoffs for the main board Tamper switch on Provision for Rear cable entry for lid protects lid and slide in accessory cavity walls Top amp box rear boards bottom knock outs for conduit entry Ness ECO8x PANEL INSTALLATION MANUAL INPUTS MONITORED ZONES The Ness ECO8x has multiple monitored inputs 8 fully programmable zone inputs Monitored by end of line resistor 1 x 24 hour Box Tamper input Normally Closed input Resistor is not required ZONE INPUTS Each zone input must be terminated with a 2K2 2200 ohm resistor as supplied All inputs must be sealed with an EOL resistor For wiring details of Keypads Keyswitches Panic Buttons and Warning devices see the wiring diagrams in the wiring section of this manual AC INPUT TERMINALS These terminals are for the connection of AC power The Ness ECO8x requires AC transformer rating of 1 4 Amps 9 17 V AC minimum Ness Part No 840 029 or POW215 BATTER
57. e keyswitch is wired to zone 8 zone 8 is then no longer available as a normal alarm input but is still available for use as a Radio Zone PROGRAMMING SEQUENCE P60E 000 65 the option ON and OFF 3E OFF No keyswitch operation Zone 8 is a normal alarm input 3E ON Zone 8 is the keyswitch input KEYSWITCH WIRING If P60E is enabled use a momentary action keyswitch with normally open contacts A momentary closed circuit across the resistor will toggle panels modes Open circuit the resistor to trigger Panic alarm if required dzE x KEYSWITCH WIRING Connect a momentary keyswitch as shown A Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING P60E 4E TAMPER SIREN LOCKOUT PROGRAM MODE LEVEL This option programs the Tamper input to Lockout i e cause the Siren amp Reset outputs to sound only once whilst the panel is armed Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE ON P60E 4E toggles the option ON and OFF RELATED OPTIONS OFF Tamper Reset Lockout disabled P44E Lockout zones ON Tamper Reset Lockout enabled P60E 6E AUTO EXCLUDE ZONES PROGRAM MODE LEVEL zone is unsealed at the end of Exit Time the panel can either Exclude ignore that zone or immediately alarm Installer Remote by PC If option P63E 7E is enabled the Siren output will give a 2 second burst at the end of Pr DEFAULT Exit Time to indicate that the panel is armed with a zone s Auto Excluded R
58. ee page 18 for Home Mode operation 24hr ZONES 24hr Zones operate at all times regardless of the mode of panel operation i e Armed Disarmed or Home Mode When alarmed these zones will activate assigned outputs immediately To reset those alarms a valid user code must be entered Selecting a zone as 24hr will override any other zone type setting such as Instant Delayed or Handover 24hr zones are independent of Area operation All other zone types must be assigned to at least one Area to become active PROGRAMMING SEQUENCE P52E Zone No E toggles the options ON and OFF Zone No OFF The zone is not a 24hr zone Zone No ON The zone is a 24hr zone DAY ZONES Day Zones operate when the panel is fully disarmed i e when Area 1 Area 2 and Home Mode are all off When alarmed these zones will activate their assigned outputs instantly The outputs mapped to the Day Zone will turn on while the zone is unsealed Turn P64E 2E on to limit Day Zone alarms to 2 seconds The Temporary Day Zones feature allows day mode to be easily enabled disabled and day zones added removed by the user from any keypad PROGRAMMING SEQUENCE P53E Zone No E toggles the options ON and OFF Zone No OFF The zone is not a Day zone Zone No ON The zone is a Day zone See page 18 for information on TEMPORARY DAY ZONES Ness ECO8x PANEL INSTALLATION MANUAL 19 PROGRAMMING Zone Output Mapping applies to zones when the
59. er the alarm beeps 5 After the Acknowledge the next message is sent until all are acknowledged 6 If the alarm is not acknowledged then the panel will hang up and redial up to the maximum number of dial attempts 7 If the alarm is not acknowledged after all dial attempts then the keypad LINE light will flash continuously until the panel is next armed ACKNOWLEDGE TONE The person receiving the call can then acknowledge the alarm by pressing the key on their telephone Press the key for 2 seconds after the alarm beeps If the alarm is not acknowledged the keypad s LINE light will flash continuously until the panel is next armed ALARM EVENTS SENT The Reporting Format Table identifies the alarm events which can be programmed to be sent in Audible Format Open Close reports Restorals and Exclusions Isolates are NOT sent in Audible Format even if selected on Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING USER CODES PIN programming and EKTRA OPTIONS for each user code EKTRA OPTIONS EXCLUDE E toggles EXTRA OPTIONS mode Installer Program mode only USER CODE TABLE PAGE 12 2 USER OPTION KEYPAD AREA ARM CODE NO PIN 2 ONLY Code ON CODE RADIO 1 Master P11E 2 12 P13E P14E P15E P16E P17E P18bE P19E P20E 123 AJO E o PROGRAMMING RADIO KEYS To progra
60. erface 100 200 Maximum keypads RADIO Header OUTPUTS Silo On board siren driver with timed output Maximum 3 x 8 Ohm horn speakers 12V DC timed output Maximum 2 x 1 Watt strobe lights 12V DC timed output Maximum 2 x 12V piezo screamers 13 8V DC output for powering detectors and other equipment Maximum 500mA Programmable AUX1 output Switches negative max draw 200mA Programmable AUX2 output Switches negative max draw 100mA AUX1 Output AUX Header APPROVALS EMC COMPLIANCE EN 50130 4 1996 Part 4 Electromagnetic compatability Electrostatic Discharge Radiated RF Immunity Electrical Fast Transient burst Surge Immunity Conducted RF Immunity Voltage Dips and Interruptions Mains Supply Variations AS NZ CISPR 22 2002 Class B Electromagnetic Radiation Terminal Disturbance Voltage EN61000 6 3 2001 Harmonic Current Emissions Voltage fluctuations and Flicker TELECOM TBR21 EU PTC200 NEW ZEALAND TELECOM AS S002 AUSTRALIA SAFETY EN60950 2000 inc Country Deviations Safety of Information Technology Equipment AS NZ3260 1993 incl AMDTS 1 2 3 amp 4 T8001 1997 ACA Australian Communications Authority A NESS SECURITY PRODUCTS Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE 8 INSTALLATION MANUAL Revision 1 5 August 2009 Document Part Number 890 354 For products 106 030 ECO8x Control Panel COPYRIGHT NOTICE All r
61. f equipment connected to AUX1 exceeds 150mA PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P69E 1E Arm1 output pulses PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES When this option is enabled the Radio Key s Panic button will no longer generate a Panic Alarm PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON PROGRAMMING AUX1 Smoke Detector Power AUX1 is 1 armed output AUX1 toggles on Radio Key AUX Option Description 5E 6E 7E 8E Q AUX1 pulses on Radio Key AUX P65E AUX1 OUTPUT OPTIONS Select one output type for AUX1 AUX1 OUTPUT SMOKE DETECTOR POWER When this option is enabled the AUX1 output can be used to provide power for latching smoke detectors which require power interruption to reset The AUX1 output is momentarily interrupted for 5 seconds by pressing 1 User code E or just 1E if the short arm P62E 4E option is enabled PROGRAMMING SEQUENCE P65E 1E turns the option ON The option is toggled off by selecting a different P65E option for Aux1 AUX1 OUTPUT AREA1 ARMED OUTPUT When this option is enabled the AUX1 output turns on when 1 is armed and turns off when the panel is disarmed The output can be optionally programmed to output a momentary pulse on arming see P69E 1E PROGRAMMING SEQUENCE P65E 2E turns the option
62. f the above is not available then it is advisable to wear clothing that will minimise the build up of static Handle circuit boards by the edges Avoid touching any components on the board as the integrated circuits in particular are not guaranteed by their manufacturers to be safe from ESD To minimise the build up of static avoid walking around as much as possible while working on the installation Touch an earthed object to discharge any static before working on the installation ADSL NOTICE ADSL broadband data can interfere with the operation of your alarm dialler It is recommended that a quality ADSL filter be installed as per the filter manufacturer s guidelines in all premises with an alarm dialler installed INSTALLATION PROCEDURES The location of the main panel housing and all keypads should be in an area that is within the protected area of the premises A linen closet or cupboard are good examples as these are generally located in the centre of the premises Positioning of the movement detectors should be considered as the incorrect position may cause unwanted alarms Remove the housing lid Remove the battery from the base Securely mount the rear panel housing to a secure location Run all cabling needed for the installation Before removing the circuit board from its protective wrapping Insert the PCB stand offs in the panel and then plug the circuit board onto the stand offs 7 Wire to th
63. he installer code is not displayed when programming For a complete list of factory default values see the Programming Options Summary on pages 54 55 Ness ECO8x PANEL INSTALLATION MANUAL ess ECOS Conor Pae suton Maw aa PROGRAMMING SPECIAL INSTALLER FUNCTIONS SEND DIALLER TEST REPORT Send a Dialler Test Report to the telephone numer programmed at 7 This test operates only in User program mode P66666666E eight 6 s Triggers dialler and sends test report to Central Station SIREN TEST Turn the Siren Reset and Strobe Outputs On Pressing P E will stop the Siren Test and also exits Program Mode This test operates in User and Installer program mode P77777777E eight 7 s Triggers Siren Reset Strobe PANEL RESET This function resets the microprocessor The effect is the same as powering down and powering up again Panel Reset operates in User and Installer program mode P88888888E eight 8 s Panel Reset PANEL MODEL amp SOFTWARE VERSION This function displays the panel software version and the model number Displayed in decimal format by the zone LEDs Example version 1 0 ECO8x is displayed by flashing 1 0 followed by 0 2 The model number for the ECO8x is 02 This test operates in User and Installer program mode P99999999E eight 9 s Displays software version 46 Ness ECO8x PANEL INSTALLATION MANUAL RADIO DEVICES OPERATION ALARM Any Ness radio devi
64. his option is useful for temporary disabling of the dialler without affecting other dialler options P86E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON P86E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES See page 53 for full details PROGRAMMING Contact ID Format Audible PULSE format Disable Dialler k m N m 3E A m 6E 7E 8 Option No Description 2 P86E REPORTING FORMATS DISABLE DIALLER This option disables the dialler even if telephone numbers and other dialler options are programmed Up download or remote telephone access remain enabled PROGRAMMING SEQUENCE P86E 1E turns the option ON ON Dialler disabled CONTACT ID FORMAT This option enables the reporting of alarms to a Central station via telephone numbers 1 amp 2 using Contact ID format PROGRAMMING SEQUENCE P86E 2E turns the option ON ON Contact ID format enabled AUDIBLE FORMAT For audible monitoring to any telephone or mobile phone The audible message consists of the warning words ALARM ALARM ALARM followed by the alarm message sent as a series of beeps The message is repeated for 4 times or until acknowledged by the receiving telephone PROGRAMMING SEQUENCE P86E turns the option ON ON Audible PULSE format enabled Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING P8
65. ights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2009 Ness Security Products Pty Ltd ABN 28 069 984 372
66. ion then EXCLUDE E toggles back to normal user code program mode When the code is viewed in program mode the ARMED icon is briefly displayed before the digits of the code To disable the Arm Only feature for a keypad code simply enter the option for that code press EXCLUDE E to view Extra Options then press 3 E without re entering a new code This retains the existing code and toggles off the Arm Only feature The Arm Only feature also applies to Radio Keys Arm Only codes can also arm the panel directly from Home Mode Normally user codes can arm the panel only if it is fully disarmed Arm Only codes can also arm Home Mode as normal Radio Keys programmed as an Arm Only can toggle the armed disarmed state of the panel using the OFF button on the radio key 12 Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING EXCLUDE E toggles the EXTRA OPTIONS MODE USER CODE The Exclude light indicates this mode is on off OPTIONS TABLE Installer Program mode only 2E 3E 4E 5E AREA 2 ARM CODE ONLY RADIO CODE CODE ONLY ARM USER USER S NAME CODE OPTION NO KEYPAD PIN For your record 1 Master P11E 123 ON PROGRAMMING USER CODES In EXTRA OPTIONS mode Exclude light is on you can assign ASSIGNING EXTRA OPTIONS several powerful functions to each user code Each user code has several extra options which can be To view
67. is armed and disarmed with the Keyswitch input or Radio Keys This option applies to siren chirps the strobe output always flashes when arming disarming by the above methods The siren output will make 1 Chirp on arming and 3 Chirps on disarming Home Mode chirps are enabled separately see P69E 7E PROGRAMMING SEQUENCE P64E 4E 000 65 the option ON and OFF OFF No Arm Disarm siren chirps ON Siren amp Strobe outputs will chirp on arm disarm Ness ECO8x PANEL INSTALLATION MANUAL Ed PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON P64E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON RELATED OPTIONS P61E 5E 8E Keypad Panic Alarm output mapping P64E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P75E 4E Report Fire Alarms P64E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P75E 2E Report Medical Alarms 50Hz MAINS FREQUENCY Selects either 50Hz or 60Hz mains power frequency operation The factory default of 50Hz is for use in Australia and New Zealand Users in North America should select 60Hz mains frequency Required for the accurate timing of dialler test reports if programmed It has no effect on other dialler operations PROGRAMMING SEQUENCE P64E 5E toggles the option ON and OFF OFF 60Hz mains frequency ON 50Hz mains frequency ENABLE
68. ll other Radio Devices is tested in INSTALLER PROGRAM Mode PRESS to test the signal strength of the selected transmitter ONLY Other devices will be ignored PRESS 4E to test the signal strength of ANY Ness transmitter including unpro grammed devices NESS RADIO NESS RADIO DEVICES Radio Events Table 6 amp RK1 RADIO KEY RK3 RADIO KEY RK4 RADIO KEY R12 RADIO PIR RR1 RR2 RADIO RPB RADIO RSM RADIO RADIO KEYPAD PENDANT 3 BUTTON 4 BUTTON R15 RADIO PIR REED SWITCH EMERG BUTTON SMOKE DETECTOR 100 001 100 683 100 664 100 067 100 691 100 663 100 662 100 527 100 283 106 040 ARM DISARM 15 User IDs ON OFF buttons ON OFF buttons ALARM yes yes yes RESTORAL yes PANIC star buttons PANIC button PANIC button PANIC button PANIC button AUX yes yes LOW BATT yes yes yes yes yes yes yes yes TAMPER yes 100 691 yes SUPERVISION yes yes yes yes NESS RADIO INTERFACE The Ness Radio Interface 100 200 is the optional radio receiver required to enable all radio functions Connection to the control panel is via a 4 wire loom and plug supplied with the Ness Radio Interface When the Ness Radio Interface is installed the keypad will flash the RADIO light ON when any radio signal is detected from both programmed and non programmed radio devices NESS RADIO INTERFACE NESS Part 100 200 CONTROL PANEL RECEIVER
69. lure BATTERY Low Battery TAMPER Tamper alarm EXCLUDE Panic alarm LINE Telephone line fail RADIO EXCLUDE Radio Key Panic alarm RADIO BATTERY ZONE Radio Device battery low Device number is indicated by zone lights RADIO BATTERY ARM Radio Key battery low Radio Key number is NOT indicated RADIO TAMPER ZONE Radio Device tamper alarm Device number is indicated by zone lights Ness ECO8x PANEL INSTALLATION MANUAL OPERATION SUMMARY OPERATION by KEYPAD by RADIO KEY to ARM Press E The panel must initially be disarmed 5 y If the Arming Shortcut is enabled P62E 5E ess User Cope or press User Cone E If Code Only Arming has been enabled for that user code Extra Option 4E to DISARM Press User Code disarm and or reset alarms Press the OFF button once Press the ON button once to arm HOME MODE M 075 Press either the m OFF button or the Area1 must initially be disarmed y If the Home Mode Shortcut is enabled 62 ON button twice Home Mode can be used if the panel d within 4 seconds is fully disarmed or if only Area2 is P69E must armed see pages 18 19 for more information PANIC al Press Fire amp Medical keys together Press ahd hold If Kevpad Panic is enabled P64E 6E O the PANIC button for at least 4 sec User C
70. m Radio Keys to the panel assign the required user code s to be Radio Codes Extra Options Mode enable 5E Example to program a Radio key to User Code 15 Press P25E EXCLUDE E 5E EXCLUDE E 1E then press the OFF button on the radio key For full instructions see page 49 PROGRAMMING RADIO DEVICES Radio PIRs Radio Reed Switches Radio Smoke Detectors OPTION DESCRIPTION PO1E Program radio devices on zone 1 PO2E POSE PO6E Program radio devices on zone 2 Program radio devices on zone 3 Program radio devices on zone 4 Program radio devices on zone 5 Program radio devices on zone 6 Program radio devices on zone 7 Program radio devices on zone 8 Options marked u can be programmed in User Program Mode ES All options can be programmed in Installer Program Mode OPTION DESCRIPTION ENTRY DELAY Time Page 1 of 2 DEFAULT EXIT DELAY Time P30E SIREN RESET Time Normal Zone Sensitivity all zones P31E 36E Vibration Sensitivity High Low none P37E Long Response Zones 1 second none P38E Long Response Zones 3 seconds Double Trigger zones Instant zones none zones 3 ENTRY DELAY zones Zone 1 HANDOVER zones Zone 2 Lockout zones RESET output AREA 1 zones All zones All zones P51E AREA 2 zones HOME MODE zones none none 19 See page 1 Day Zones 8 f
71. moke detectors Connect smoke detector negative to Aux1 Max current draw 200mA ZONE WIRING NORMALLY CLOSED N C DEVICES ZONES 1 8 TO RECEIVER HEADER HY DATA RSSI ov t eH 2 2 Zone 010 NORMALLY OPEN 0 DEVICES Zone 1 8 A NES Ness ECO8x PANEL INSTALLATION MANUAL NESS QUANTUM DETECTORS 4 WIRE CONNECTION NESS ECO8x CONTROL PANEL ov 12V Zone 1 8 C goles NESS QUANTUM DETECTOR all models 8 DEVICES WIRING ANY N C DEVICE NESS ECO8x CONTROL PANEL ov 12V Zone 1 8 Cc pojes REED SWITCH N C contacts EXAMPLE 2 NESS EC08x CONTROL NESS QUANTUM DETECTOR as 24hr all models EXAMPLE 5 SIREN WIRING NESS ECO8x N O TAMPER SWITCH 761 002 Colour BLACK NESS QUANTUM DETECTORS 6 WIRE CONNECTION With Tamper EXTERNAL cagagg B nS ANY N 0 DEVICE NESS ECO8x CONTROL PANEL ov 12V Zone 1 8 Cc coes o 4 PANIC BUTTON N O contacts INTERNAL 100 238 Top Hat 12V Piezo Screamer 100 172 Ness 12V Internal Siren 100 004 Flush Piezo Screamer BLACK RED
72. n for Aux2 AUX2 OUTPUT PULSE ON RADIO KEY PANIC BUTTON When this option is on RK4 Radio Key s PANIC button will PULSE the AUX2 output on for 2 seconds PROGRAMMING SEQUENCE P66E turns the option ON The option is toggled off by selecting a different P66E option for Aux2 AUX2 OUTPUT LINE FAIL OUTPUT When this option is enabled a telephone line fault condition will turn on the Aux2 output Aux 2 will turn off when the telephone line is restored P89E 5E must be on to enable the Line Fail Monitor PROGRAMMING SEQUENCE P66E 5E turns the option ON The option is toggled off by selecting a different P66E option for Aux2 Ness ECO8x PANEL INSTALLATION MANUAL E P66E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF P68E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES The 3K3 zone resistor option is useful when installing the panel in a site pre wired with resistors When the 3K3 zone resistor option is not compatible with the Zone 8 Keyswitch option See P60E page 22 P68E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P64E 4 Radio Key Chirps P69E 5E Home Mode by Radio Key ON OFF buttons PROGRAMMING 2 OUTPUT FAIL TO COMMUNICATE OUTPUT When this option is enabled AUX will turn on at the start of the fourth dialout attempt This can be
73. new PIN code followed Keypad codes can be 3 to 6 digits by E in length 5 MEME Enter your new PIN code again The new code will be displayed on the keypad one digit at a time P86E2E Turns on option P86E 2E Enables Contact ID format P70E Selects the option for Telephone The existing number will be displayed on Number 1 the keypad one digit at a time 8 E Enter the telephone number The new number will be displayed on the followed by E max 30 digits keypad one digit at a time 8 P72E Selects the option for the Client The existing number will be displayed on Account Number the keypad one digit at a time 10 ____ Enter the Account number The new number will be displayed on the followed by 4 digit account number keypad one digit at a time supplied by your monitroing company 11 PE program mode Program light will turn off Ness ECO8x PANEL INSTALLATION MANUAL FACTORY DEFAULTS Master Code 123 Installer Code 000000 INSTALLER PROGRAM MODE Installer Program Mode allows access to ALL program options Note The panel will remain in Installer Program Mode indefinitely USER PROGRAM MODE User Program Mode allows the owner to program All User Codes Entry Exit Times Follow Me Telephone number Note The panel will automatically exit User Program Mode to Operating Mode if no keypad buttons are pressed for 4 minutes OF Ness ECO8x PAN
74. ning Reports enabled MANUAL EXCLUDE REPORT Enables Manual Exclude Reports for zones Exclude Reports for 24hr zones are sent on exiting EXCLUDE mode PROGRAMMING SEQUENCE P88E 7E toggles the option ON and OFF OFF No Manual Exclude Reports ON Manual Exclude Reports enabled AUTO EXCLUDE REPORT Enables Auto Exclude Reports for Zones Zones not sealed on arming will be reported as Auto Excluded PROGRAMMING SEQUENCE P88E 8E toggles the option ON and OFF OFF No Auto Exclude Reports ON Auto Exclude Reports enabled Ness ECO8x PANEL INSTALLATION MANUAL g PROGRAMMING P89E 1E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON RELATED OPTIONS P83E Test Call Interval P84E Time before next Test call P87E 4E Number Of Dialling Attempts P89E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON P89E 3E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Siilsla amp ilwilsislg Ds 8 512 1 1 21 e 1 2 12 o s 1 o D LL c S Sls o o to c 3 E Option No Description 1E 2E 4E 5E 6E 7E 8 P89E MISC REPORTING OPTIONS ON ON ENABLE TEST CALLS This option enables the reporting of dialler test calls to the Central station PROGRAMMING SEGUENCE P89E 1E toggles the option ON and OFF OFF No
75. oggles the options ON and OFF Zone No OFF The zone is not a Double Trigger zone Zone No ON The zone is a Double Trigger zone INSTANT ZONES Instant Zones operate only in the Armed state When Armed at the expiry of exit time Instant Zones will activate assigned outputs immediately when triggered P40E Zone turns the options ON Zone No ON The zone is an Instant Zone To deselect the option select a different zone delay type ENTRY DELAY1 ZONES Entry Delay1 zones operate only in the Armed state When Armed at the expiry of exit time these zones will activate the Entry Delay Timer1 P26E when they are triggered If the panel is not disarmed before the expiry of the Entry Delay Timer1 the alarm outputs will be activated P41E Zone turns the options ON Zone No ON The zone is an Entry Delay1 zone To deselect the option select a different zone delay type Ness ECO8x PANEL INSTALLATION MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 2E ON NOTES When a zone is selected for this type it is automatically deselected from any other delay type PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All ON NOTES The SIREN output always locks out PROGRAMMING SHORTCUTS Use 0E to turn all selections OFF Use MEMORY E to turn all selections ON RELATED OPTIONS P60E 4E Tamper Reset Lockout P78E Multiple alarm reports AREA PARTITIONING
76. on 123 4 5 6 7 8 P45E AREA 1 ZONES ON ON ON 46 AREA 2 ZONES ASSIGNING ZONES TO AREAS Assign or remove zones that will operate in Area 1 and or Area 2 PROGRAMMING SEGUENCE P45E Zone No E toggles the options ON and OFF for Zone No OFF The zone is not in Areat Zone No ON The zone is in Area P46E Zone No E toggles the options ON and OFF for Area2 Zone No OFF The zone is not in Area2 Zone No ON The zone is in Area2 EXAMPLE To program zones 1 4 for Area 1 and zones 1 5 8 for Area 2 P45E use the Zone No E sequence to turn ON only zones 1 4 P46E use the Zone No E sequence to turn ON zones 1 5 8 In this example we have assigned zone 1 to both areas so it becomes a Common Zone Ness ECO8x PANEL INSTALLATION MANUAL 17 PROGRAMMING AREA PARTITIONING DEFINITION Area Partitioning allows the control panel zones to be split into two partitions 1 and Area2 The panel then effectively oper ates as two separate systems sharing only the siren outputs and dialler COMMON AREA ZONES Zones assigned to both Areas are armed only when Area1 and Area2 are both armed This allows the Common Area zone s to be shared by both Areas For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically arm when
77. one number is used to prevent unauthorised up download The panel will dial the callback telephone number to commence a NessComms up download session NessComms up download without callback is allowed by turning off option P9OE 8E PROGRAMMING SEQUENCE P81E existing telephone number is displayed ENTER NEW TELEPHONE No E new Telephone No is displayed one digit at a time 34 Ness ECO8x PANEL INSTALLATION MANUAL P72E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 0000 CLIENT CODE NOTES Note 1 The ECO8x keypad does not display the Hex digits A test report should be sent to the central station to verify th correct account number Note 2 Hex digit A is not allowed PROGRAMMING CLIENT ACCOUNT NUMBER The Client Account number identifies a monitored system to the central station PROGRAMMING SEQUENCE P72E existing account number is displayed one digit at a time ENTER NEW ACCOUNT No E new account number is displayed one digit at a time EXAMPLE To program Client Account No to be 1239 P72E 1239E HEX CLIENT CODES Dialler client codes can now be entered in Hexadecimal Use the following keys to enter the hex digits B C D E or F HEX DIGIT KEY ENTRY KEYPAD DISPLAY B FIRE Key 11 C ARM Key 12 D Home Key 18 E EXCLUDE Key 14 F MEMORY key 15 Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING 74 PROGRAM MODE LEV
78. ope KEYPAD DURESS Press 5 6 8 on 9 User Cove E Keypad Duress allows the user to send a silent duress report while disarming if Add one these digits in front of a user code when disarming the system is being monitored by a central This sequence will disarm the panel and send a Duress report by dialler to the central station station Report Keypad Duress must be enabled P75E 1E EXCLUDE ZONES EXCLUDE E can only be used when the Press If the Exclude Shortcut is enabled P62E 2E panel is disarmed then Zone No Zone No Enter the zone number s to be excluded EXCLUDE CODE E can be used anytime press E to exit Exclude mode The Exclude light flashes constantly while zones are excluded Excluded zones are automatically Included next time the panel is disarmed user code is assigned to a radio key and has Extra Option 4E enabled Code Only arming then pressing OFF toggles the panel arm disarm state TEMPORARY DAY ZONE 02 operation While remaining in normal operating mode the user can add and remove Temporary Day Zones and enable disable day zone operation The panel must initially be disarmed _ Press To enter TDZ Selection Mode P64E 2E must be on to enable the then press Zone No E To select one or more zone to be Temporary Day Zones use of Temporary Day Zones porary may then press To save changes and exit TDZ Selection Mode See pag
79. option ON and OFF OFF Clock uses mains frequency timing ON Clock uses internal timing Ness ECO8x PANEL INSTALLATION MANUAL 43 PROGRAMMING amp o 9 o pes gt lt 2 25 E 2 og Option Description 1E 2E 4E 5E 6E 7E 8 P90E UPLOAD DOWNLOAD OPTIONS AAA REMOTE access PROGRAM MODE LEVEL When d ja this nm the iE d remotely upload downloaded by Installer Remote by PC a remote computer or controlled by a remote telephone When the option is Off the panel will not answer incoming telephone calls preventing DEFAULT any type of remote access RELATED OPTIONS PROGRAMMING SEQUENCE P91E Required Rings P90E 1E toggles the option ON and OFF OFF No Remote Access ON Remote Access enabled P90E 7E REMOTE EVENT REPORTING PROGRAM MODE LEVEL Enables Remote Event Reporting Installer Remote by PC PROGRAMMING SEQUENCE FACTORY DEFAULT P90E 7E toggles the option ON and OFF FF g OFF No Remote Status Reporting ON Remote Status Reporting enabled P90E 8E CALLBACK MODE PROGRAM MODE LEVEL Enables two methods of connecting by computer for remote upload download Installer Remote by PC NO CALLBACK Allows remote access by computer as long as the panel s Account FACTORY DEFAULT Number P72E is known The panel answers on the 2nd incoming call OFF WITH CALLBACK The panel will answer the
80. or information on Area operation Home m ode amp Temporary P52E 24hr zones none P53E Day Mode zones none 19 P54E RESET output zones All zones P55E STROBE zones All zones P56E Keypad Sonalert zones SIREN zones All zones All zones Aux2 zones Entry Beeps none Keyswitch Arm Disarm Siren lockout Auto Exclude zones Auto keypad display off Tamper to RESET output Tamper to STROBE output Tamper to Keypad Sonalert Tamper to SIREN output Keypad Panic to RESET output Keypad Panic to STROBE output Keypad Panic to Sonalert Keypad Panic to SIREN output Shortcut Memory display Shortcut Zone Exclude Shortcut Home Mode Shortcut SMOKE RESET Shortcut Area1 Arming Shortcut Area 2 Arming Siren Burst on Auto Exclude Exit Time x10 Ness ECO8x PANEL INSTALLATION MANUAL OPTION Pe3bE 1E 2E 3E 4E 5E 6E 7E 8E P64E 1E 2E 3E 4E 5E 6E 7E P65E 1E 2E 3E 4E DESCRIPTION Home Mode alarms to RESET output DEFAULT Home Mode alarms to STROBE Home Mode alarms to SONALERT Home Mode alarms to SIREN Day Mode to RESET output OPTION 82 1 2 4 DESCRIPTION Send RESTORAL report immediately 2 of 2 DEFAULT Send RESTORAL after siren time Send RESTORAL after Disarm amp seal
81. panel is in the Armed or 24hr state For HOME MODE and DAY mode Output Mapping see Option P63E 1E 8E page 26 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All ON PROGRAMMING SHORTCUTS Use OE to turn all selections OFF Use MEMORY E to turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all ON PROGRAMMING SHORTCUTS Use OE to turn all selections OFF Use MEMORY E to turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All ON PROGRAMMING SHORTCUTS Use OE to turn all selections OFF Use MEMORY E to turn all selections ON ZONE TO OUTPUT MAPPING When a zone alarms it can turn on any or all of these outputs Sonalert Strobe Siren Reset AUX2 The programming is selected with options P54E P59E Simply set the zone number to the output to select it The zone LED will indicate if the zone is se lected The Tamper Input and the Keypad Panic can be mapped to the Reset Strobe Sonalert and Siren by using option P61E MAPPING ZONES TO OUTPUTS ZONES Option No Description 1 2 34 5 6 7 8 P54E RESET Zones ON P55E STROBE Zones ON ON ON ON P56E SONALERT Zones ON ON ON 57 SIREN Zones ON P59E AUX2 Zones RESET OU
82. red by alarms in Day Mode PROGRAMMING SEQUENCE P63E 5E 8E toggles the options ON and OFF 5E ON Day Mode to Reset output 6E ON Day Mode to Strobe output Select this option to activate the STROBE output when a DAY alarm occurs Note that if P64E 2E is ON this option will select Aux 2 Output instead of the Strobe Output This allows a remote warning device to be connected P66E 1E must also be ON ON Day Mode to Keypad Sonalert output 8E ON Day Mode to Siren output Ness ECO8x PANEL INSTALLATION MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P51E Set Home zones P63E 1E 4E Home Mode output mapping PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P53E Assign Day zones P63E 5E 8E Day Mode output mapping PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES Note that not all keypads have the Chime sound RELATED OPTIONS P64E 1E Brief Home Mode Alarm P64E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P68E 8E Quiet Chirps P69E 5E Home Mode arming by Radio Key ON OFF buttons P69E 7E Home Mode by radio key Chirps PROGRAMMING 2 E c SE E w c e o 5 3 Elg z 8 1 51 1518 gt 2 olo d cm a N a GAMES
83. rmed Day Mode enabled disarmed in Home Mode see page 18 Yellow Illuminated button PERS Normal Memory mode New alarm s in selected memory Red Illuminated button EXE Normal Zone s are E Excluded Red Illuminated button Normal User Program Installer Program P PROGRAM Red Illuminated button Mode Mode ARM O 2 Yellow LED Area 2 is Disamed Area 2 is Armed ARMe Normal The backup battery O BATTERY Red LED is low Normal Mains power is off A MAINS Red LED READY Zone s are unsealed Ready to arm O READY Green LED or Power is off the panel or Panel is armed or phone line fault ARMe Normal The Internal Tamper O TAMPER Red LED inputis in alarm ARMe2 Normal Receiving a A Radio Key or e RADIO Red LED radio signal If other radio device radio fitted has low battery Dialler is Phone line fault QO LINE Red LED line or failure to communicate lt 2 J3BEEPS Valid Command Ji LONGBEEP Error Mains Power is off or Panel Battery is low or A Radio Device has sent a low battery signal or Telephone Line Fail has been detected o 4 10 BEEPS KEYPAD DISPLAY INDICATORS IN MEMORY MODE KEYPAD LIGHT MEMORY EVENT Zone lights 1 8 Zone alarm no lights Panel Disarmed ARMED Panel Armed or Area 1 Armed ARM2 Area 2 Armed MAINS Mains power fai
84. rogramming The Installer Code Installer Code default 000000 RELATED OPTIONS Programming Radio Codes page 49 IMPORTANT NOTES O A User Code can bea Keypad Code Radio Code or Reader Code but only one type at any one time user codes Radio Codes automatically Codes factory default all user codes Keypad Codes O When user code is selected as Radio Code its Keypad Code if any is automatically deleted The same applies to Radio Codes their codes are auto deleted when the code is changed to any other type O User Code 1 is the Master Code and is always a keypad code and cannot be programmed to be a Radio Code RADIO PROGRAMMING See pages 48 49 USER CODES The 8 control panel has 15 User Codes which are used to operate the panel by a variety of methods each User Code can be assigned to either a KEYPAD CODE or a RADIO KEY KEYPAD PIN CODES Up to 15 Keypad Codes can be used at up to 3 wired keypads for controlling all panel functions including Arming Disarming Home Mode Panic memory recall and much more Keypad Codes can be 3 to 6 digits in length and can be individually programmed and deleted Keypad Codes can optionally be programmed to be Arm Only codes User Code 1 is also the Master Code which is used to enter Client Program mode All User Codes are Keypad Codes by default User Codes can be
85. scellaneous alarms will trigger the dialler to send Alarm reports and Restoral reports to the Central Station Alarms if enabled are sent on activation Restorals if enabled are sent on Opening Mains Fail and Low Battery Restorals are sent when the power has been restored PROGRAMMING SEQUENCE PxxE 1E 8E toggles the option ON and OFF m Send immediately Send after siren time Send after disarm amp seal N m e m Option No Description 5E 6E 7E 8E Send after disarm always P82E ZONE RESTORAL REPORTING OPTIONS P82E 1 4 RESTORAL REPORTING OPTIONS This option selects when the dialler sends zone Restoral reports Only one of the PROGRAM MODE LEVEL following options may be selected stellt Harte DYRO Restoral reporting options also apply to 24hr zones FACTORY DEFAULT 4E ON PROGRAMMING SEQUENCE RELATED OPTIONS P82E 1E 4E toggles the option ON and OFF P76E Report zone restorals 1E ON Send Restoral immediately 2E ON Send Restoral after siren time 3E ON Send Restoral on Disarm amp seal 4E ON Send Restoral on Disarm always Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 84 168hrs 7 days NOTES Enter a value from 1 to 99 RELATED OPTIONS P89E 1E Enable Test Calls P84E Time Before Next Test Call P84E PROGRAM MODE LEVEL Installer Remote by PC FAC
86. set and Strobe outputs are protected by Automatic Reset elec tronic fuses These outputs will automatically reset once the overload is removed BACKUP BATTERY A properly charged battery must be installed to ensure the Siren Strobe and Reset outputs operate correctly SIREN LOAD A maximum output of 2 0A continuous is available from the SIREN and RESET outputs and 200mA from the STR output Recommended maximum power load 3 x Horn speakers SIREN output 2 x Strobe lights STR output 2 x Ness Internal Sirens 100 172 RESET output Note This assumes no more than 500 is being drawn from the 12V device outputs Ness ECO8x PANEL INSTALLATION MANUAL LEAD AUX2 OUTPUT Programmable for zone alarm output or Area2 arm output or Radio AUX channel output Max current draw 100mA RECEIVER Header for connecting optional Radio Interface BATTERY LEAD supplied RED BLACK BATTERY CONNECTION For 12V 7Ah backup battery BAT210 Connect to Mode3 socket Lead shown is for Australia only TELEPHONE TAMPER PROG LINK BOX TAMPER amp PROGRAM LINK s Sealed normal state Tamper alarm state Power up with link off to enter installer program mode eXNV M er TAMPER PROG HEARTBEAT LED Constantly flashes 39313933 ECO8x HOUSING TAMPER SWITCH N C Contacts WHITE
87. staller Remote by PC FACTORY DEFAULT OFF NOTES Radio Key Home Arming will work only if one or more zones have been programmed as Home Zones P51E When using a Radio Keypad to Home arm ensure that the ARM ONLY option is OFF for the USER CODE on the panel Otherwise further Home E keypresses on the Radio keypad could AREA arm the panel RELATED OPTIONS P51E Program Home zones P63E Home Mode output mapping P64E 1E Brief Home Mode alarm P69E Quiet Home Mode siren P69E 7E Home Mode chirps by Radio Key P69E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES This does not affect Dialler mains fail reporting or saving to the History memory P69E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P68E 8E Quiet Chirps P69E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF RELATED OPTIONS P51E Program Home Mode zones P63E Home Mode Mode output mapping P64E 1E Brief Home Mode alarm P64E 4E Radio Key Chirps P69E 3E Quiet Home Mode siren PROGRAMMING HOME MODE ARMING BY RADIO KEY ON OFF Setting this option on allows Home Mode arming by Radio Key ON or OFF buttons Note This is independent of Home arming by AUX button if using the RK4 radio key PROGRAMMING SEQUENCE P69E 5E toggles the option ON and OFF OFF Radio Key Home Mode Arming disabled ON Radio Key Home Mode Arming enabled OPERATI
88. t while allowing free movement within the house Home Mode will not work if Area 1 is armed Zones which are to be armed in Home Mode are selected using option P51E Home Mode can be armed by Keypad HOME code E or HOME E Radio Key See option P69E 5E Audible outputs in Home Mode set by options 6 1E 4E are independent of audible outputs in fully armed mode If dialler reporting is enabled Home Mode alarms will be reported as normal providing that a The zone s are selected to report alarms by option P74E b Option P64E 1E is off Brief Home Mode Alarm Home zones can be Instant Delayed or Handover depending on attributes set by options PAOE P42E RELATED OPTIONS P64E 2E Brief Day Alarm Turn this option onto enable Temporary Day Zones Factory default OFF P63E 5E Day Mode to Reset output P63E 6E Day Mode to Strobe output If P64E 2E is ON then this option sends day alarms to the AUX 2 output P63E 7E Day Mode to Sonalert P63E 8E Day Mode to Siren output P53E Permanent Day Zone selection Day Zone selections will be lost if the panel is powered down or reset but are not affected by arming disarming or entering program mode 18 Ness ECO8x PANEL INSTALLATION MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES Home zones can be Instant Delayed or Handover depending on attributes set by options P
89. the option ON and OFF OFF OFF Exit Time is the time set by P28E RELATED OPTIONS ON Exit Time is multiplied by 10 P28E Exit Time EXAMPLE If P28E 22 seconds then if P62E 8E is ON the exit time is 22 x 10 220 seconds Ness ECO8x PANEL INSTALLATION MANUAL PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E 2E ON 3E 4E OFF RELATED OPTIONS P64E 1E Brief Home alarm P63E 5E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5E 6E ON 7E 8E OFF RELATED OPTIONS P64E 2E Brief Day alarm For ZONE TO OUTPUT MAPPING for armed amp 24hr states see options P54E P59E 20 21 Option No Description Home Mode to RESET output m Home Mode to STROBE output Home Mode to keypad SONALERT amp Home Mode to SIREN output 1 Day Mode to RESET output Day Mode to STROBE output m Day Mode to keypad SONALERT 02 Day Mode to SIREN output P63E HOME MODE amp DAY MODE MAPPING ON 2 ON ON HOME MODE OUTPUT MAPPING This option selects which outputs are triggered by alarms in Home Mode PROGRAMMING SEGUENCE P63E 1E 4E toggles the options ON and OFF 1E ON Home Mode to Reset output 2E ON Home Mode to Strobe output 3E ON Home Mode to Keypad Sonalert output 4E ON Home Mode to Siren output DAY MODE OUTPUT MAPPING This option selects which outputs are trigge
90. the transmitter The Signal Strength display remains on until another command is entered To clear the display and re test the transmitter simply press 3E again 8 0 0 1 Best Signal 8 beeps 060969 Weak Signal 1 beep gt Ness ECO8x PANEL INSTALLATION MANUAL NESS RADIO PO1E POSE PROGRAM MODE LEVEL Installer FACTORY DEFAULT No Radio Devices programmed NOTES Radio Device programming is done by automatically enrolling the radio code into the control panel Radio Devices can only be deleted by keypad Some Ness Radio Devices send separate Alarm and Restore signals For special purposes radio zones can be also programmed to accept radio keys In this case the zone can not also be programmed to accept a radio device RADIO DEVICES OPTION TABLE Zone 1 PO1E Zone 2 PO2E Zone 3 POSE Zone 4 PO4E Zone 5 POSE Zone 6 PO6E Zone 7 PO7E Zone 8 PO8E TIP To prevent conflicting radio signals when programming Radio Devices disable each device once you have finished programming it Remove the battery or open the RADIO link Remember to enable all the devices when programming is completed 100 527 100 662 Ness Universal Ness Radio 100 691 100 663 Transmitter Reed Switch Ness R12 Radio PIR Ness R15 Radio PIR RADIO DEVICE PROGRAMMING Each of the zones of the ECO8x can be a radio zone
91. ue between 1 and 7 1 Sunday Default 1 Sunday PROGRAMMING SEQUENCE P130E P135 existing value is displayed one digit at a time ENTER NEW VALUE E new value is displayed one digit at a time Ness ECO8x PANEL INSTALLATION MANUAL INSTALLER S NOTES Ness ECO8x PANEL INSTALLATION MANUAL CENTRAL STATION MONITORING The Ness 8 control panel has on board digital dialler which can send detailed alarm messages to a central monitoring station MONITORING The digital messages can include information about the zone s which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who arm and disarm the system Central station monitoring is highly recommended and is the most effective method of monitoring your alarm system Installers are welcome to contact Ness for further information about monitoring The panel reports alarms to the Central CONTACT ID REPORTS TA Station using Contact ID dialler format The message format is fixed as shown REPORT NAME SSSS Q xv GG CCC SUFFIX Contact ID Codes Table Zone 1 Zone 8 Alarm 555518 q 130 001 008 k THE MESSAGE TAKES THE F
92. uence RELATED OPTIONS P87E 1E Alternate Primary Secondary telephone numbers P86E 1E Disable dialler still allows remote up download if programmed PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT None RELATED OPTIONS P9OE 8E Enable Callback Option No Description Default P70E TELEPHONE NUMBER 1 PRIMARY P71E TELEPHONE NUMBER 2 SECONDARY P81E TELEPHONE NUMBER CALLBACK FOR UPLOAD P72bE CLIENT ACCOUNT NUMBER 0000 TELEPHONE NUMBERS 1 amp 2 The panel can dial up to 2 phone numbers when an event is to be transmitted to a central monitoring station or other location Telephone numbers may be up to 30 digits in length PROGRAMMING SEQUENCE P70E existing telephone number is displayed one digit at a time ENTER NEW TELEPHONE No E new telephone number is displayed one digit at a time EXAMPLE To program Telephone No 1 to be 03 1234 1234 P 70 E 0312341234 E TO CLEAR A TELEPHONE NUMBER To clear a telephone number enter the MEMORY key in place of the telephone number Example to clear a Telephone Number 1 press P7OE MEMORY E SPECIAL CHARACTERS Applies to all telephone Numbers Pauses star or hash VF digits can be included in the dialling sequence by using the keys in the table below SPECIAL CHARACTER KEY ENTRY KEYPAD DISPLAY PAUSE 1 6sec ARM Key 12 Star Home Key 10 Hash EXCLUDE Key 11 TELEPHONE NUMBER CALLBACK This teleph
93. uipment This output is protected by an Automatic Reset fuse A maximum load of 500mA may be connected SIREN The on board siren driver will drive a maximum of 3 x 8 ohm horn speakers Ness Part No 0110 The output will reset at the end of siren time P29E or whenever the panel is reset whichever comes first This output is protected by an Automatic Reset fuse STR A latched 12VDC output for connecting strobe lights This output will reset after 72 hours 3 days or when the panel is disarmed A maximum of 2 x 1 Watt Strobes Ness Part No NOI300 can be connected to this output This output is protected by an Automatic Reset fuse RESET A 12V DC output for connecting Ness sirens piezo sirens or relays etc This output will reset at the end of siren time P29E or whenever the panel is reset whichever comes first A maximum of 2 x 12V piezo screamers Ness Part No 100 238 100 004 100 172 can be connected to this output This output is protected by an Automatic Reset fuse AUX1 The Aux 1 output is on the main terminal strip Programmable for Smoke Detector power Area1 arm output or Radio Key AUX button output default see program option P65E Max current draw 200mA AUX2 The Aux2 output is a two pin header J3 Aux2 is an open collector output switches negative Programmable for various types of outputs see program option P66E Max current draw 100mA OUTPUT FUSING The 12V outputs Siren Re