        Helix VLT User`s Manual Rev. F
         Contents
1.     INSTRUCTION    WHAT TO DO IF YOU SMELL GAS     Do not try to light any appliance        Do not touch any electrical switch  do not use  any phone in your building        Immediately call your gas supplier from a  neighbor   s phone  Follow the gas supplier   s  instructions     e If you cannot reach your gas supplier  call the fire  department        2 2 TO TURN OFF GAS TO APPLIANCE  e Set thermostat to lowest setting        Turn  OFF  all electric power to appliance if service is  to be performed     e Remove front jacket panel        Turn gas shutoff valve handle clockwise CY to closed  position  Handle should be perpendicular to gas pipe     e Replace front jacket panel   2  1 Gas Shutoff Valve                  Gas Shutoff Valve    DS GASSHUTORF  TT VALVE     E   oo  i  I  k       CLOSED POSITION    w    3   CONTROL MODULE    3 1 Introduction Operation with LCD character display module    Boiler is equipped with a programmable electronic control  and user interface module     3 2 Operation       amp     Manual Lockout Reset    CD   Enter Exit user menu    Go to previous screen       initial a  gt   VERSION  xx Xx X               Scroll down to next menu item    Decrease value         CD   Select a menu item    Confirm new parameter value  4     Scroll up to next menu item      Increase value    3 3 Status Indication  The following status screens can be displayed     Boiler Status Indicator     Bo  F   Flame Detected  5  P   Central Heating System Pump On  B   Combustio
2.  Y         Boiler runs provided all operational and  Normal Operation safety devices within limits   CENTRAL HEATI NG     5   135   F Control Module adjusts firing rate to             match heating demand     Call for heat ends  Post purge cycle for  Thermostat Ends 30 seconds  m    Call for Heat       CENTRAL HEATING En Air Blower modulates to post  Post Purge 65  75   F purge setting     CH System Pump  DHW pump  and Heat  Exchanger Pump operate     u Ready for p  Operation UP S PS pA  Boiler returns to Standby Mode     75   F                      3 5 Theory of Operation          User Interface Display Explanation          Boiler operates in standby mode until Central Heat  CH  or  Domestic Hot Water  DHW  demand detected         Access User Menu by pressing    Menu    key on user interface         STANDBY    User Menu structure  Use scroll keys to move to desired menu   and press Enter           Boiler Status    submenu         Settings    submenu   View CH   DHW supply water set  point and select control language      Cascade Status  submenu   Boiler set to function as  part of multiple boiler installation  submenu used to view  runtime parameters  See Multiple Boiler Manual     User Menu         Supply Temperature set point displayed   CH set point displayed if boiler running in CH mode     Note  Value may change in proportion to outdoor tempera   ture when running in Outdoor Reset mode    DHW supply set point displayed if boiler is running in DHW  mode     Water Tempera
3. USER S  INFORMATION  MANUAL    WARNING  If the information in this manual is not  followed exactly  a fire or explosion may result causing  property damage  personal injury or loss of life     Do not store or use gasoline or other flammable  vapors and liquids in the vicinity of this or any  other appliance     WHAT TO DO IF YOU SMELL GAS     Do not try to light any appliance      Do not touch any electrical switch  do not use  any phone in your building        Immediately call your gas supplier from a  neighbor s phone  Follow the gas supplier s  instructions    e If you cannot reach your gas supplier  call the  fire department            Installation and service must be performed by a  qualified installer  service agency or the gas    supplier        Information and specifications outlined in this manual in effect at the   time of printing of this manual  Manufacturer reserves the right to   discontinue  change specifications or system design at any time without   notice and without incurring any obligation  whatsoever  P N 240008847  Rev  F  06 2013     1  GENERAL    1 1 General    This boiler has few user serviceable parts  Maintenance  and Service must be completed by qualified agency     1 3 What To Do Should Overheating Occur    Do not turn off or disconnect electrical supply to pumps   Shut off gas supply at location external to appliance     1 4 What To Do If Boiler Or Any Part Has Been  Under Water   Do not use boiler if any part has been under water   Immediately c
4. all a qualified service technician to inspect  boiler and to replace any part of control system and any  gas control which has been under water     Fire  explosion  asphyxiation and electrical shock  hazard  Improper maintenance and service could    result in death or serious injury  Read this manual  and understand all requirements  including use of  qualified agency where directed        1 2 Become familiar with symbols identifying  potential hazards     A    This is the safety alert symbol  Symbol alerts you to  potential personal injury hazards  Obey all safety messages  following this symbol to avoid possible injury or death     A DANGER    Indicates a hazardous situation which  if not avoided   WILL result in death or serious injury    Indicates a hazardous situation which  if not avoided   could result in death or serious injury     Indicates a hazardous situation which  if not avoided   could result in minor or moderate injury     NOTI CE  Used to address practices not related to personal    injury        2   OPERATIN  FOR YOUR SAFETY READ BEFORE OPERATING    If you do not follow these instructions  exactly  a fire or explosion may result  causing property damage  personal injury  or loss of life   e This appliance is equipped with an ignition device  which automatically lights burner  Do NOT try to  light this burner by hand     e Before operating smell all around appliance area  for gas  Be sure to smell next to floor because  some gas is heavier than air and will s
5. condensate drain trap inside boiler        Follow instructions TO TURN OFF GAS TO  APPLIANCE  See section 2        Inspect condensate drain trap for sediment or  blockage  Contact qualified agency if cleaning  required        Inspect system piping for leaks  Contact qualified  agency  as necessary        Check air vent s  for leakage        Follow OPERATING INSTRUCTIONS to return to normal  operation     5 3 Check According to Manufacturer s  Instructions    e Safety Relief Valve   Refer to manufacturer s  instructions     Burn and scald hazard  Verify Safety Relief Valve    discharge piping run to safe discharge location  before conducting maintenance procedure  Contact  qualified agency to correct improper piping        5 4 Annually or Beginning Each Heating Season       Contact qualified agency to perform maintenance and  cleaning per Installation  Operation and Maintenance  manual  Inspection will include examining all flue  product carrying areas  vent system  burner and heat  exchanger  Will also include filling boiler with water if  drained as part of End of Heating Season procedure     5   MAINTENANCE    5 5 End of Heating Season  if boiler not used for  domestic hot water      Follow instructions to TURN OFF GAS TO APPLIANCE   See section 2   e Contact qualified agency to drain heating system  if  system does not use antifreeze  and condensate trap  if heating system is exposed to freezing temperatures  while out of service     10    E NOTE    ER SERVI    Installer I
6. ettle to the  floor        Use only your hand to turn the gas shutoff  valve  Never use tools  If valve will not turn  by hand  do not try to repair it  call a qualified  service technician  Force or attempted repair may  result in fire or explosion        Do not use this appliance if any part has  been under water  Immediately call a qualified  service technician to inspect appliance and to  replace any part of control system and any gas  control which has been under water        2 1 OPERATING INSTRUCTIONS  Stop  Read Safety information above   e Set thermostat to lowest setting        Turn  OFF  all electrical power to appliance     e This appliance is equipped with an ignition device which  automatically lights the burner  Do not try to light  burner by hand     e Remove front jacket panel        Turn gas shutoff valve clockwise CY to closed position   Handle should be perpendicular to gas pipe     e Wait 5 minutes for any gas to clear  Smell for gas   including near floor  If you smell gas  STOP  Follow  instructions on this page     What To Do If You Smell  Gas     If you do not smell gas  go to next step        Turn gas shutoff valve counter clockwise     to the  open position  Handle should be parallel to gas pipe        Replace front jacket panel      Turn  ON  electrical power to appliance   e Set thermostat to desired setting        If the appliance will not operate  follow instructions TO  TURN OFF GAS TO APPLIANCE and call your service  technician or gas supplier 
7. n Air Blower On  S   Safety Relay Check  G   Gas Valve Open  D   DHW Pump On    F   Service Reminder I ndicator   lt     Boiler in Standby Mode    Boiler Supply Water  Temperature Indicator    Boiler Running in Central    Combustion Air Blower Heat mode    Speed Indicator    Boiler Running in DHW  mode    Lockout Alarm Indicator  Error code and short text de   scription displayed    Press Reset key for manual  reset     Blocking Error   Error code and short text  description displayed  Boiler  automatically returns to  Standby Mode when condition  eliminated        3   CONTROL MODULE    3 4 Sequence of Operation    Operational State User Interface Display Explanation    Boiler operates in standby mode until  Ready for demand for Central Heat  CH  or       Operation TE VPT SSS WE Domestic Hot Water  DHW  detected   75   F      Call for heat     CH System or DHW pump turned ON   Thermostat Starts based on type of heating demand  Heat  Call for Heat CENTRAL HEATI NG Exchanger Pump also turned ON    0  75   F                      CH demand illustrated        Pre Purge Combustion Air Blower energized     CENTRAL HEATI NG  100  75      F             Combustion Air Blower speed  CENTRAL HEATING modulates to prepurge setting for 15    65  75  F seconds        y         me Igniter energized to start sparking  Trial for Ignition sequence   CENTRAL HEATING    6 5   75  F             Gas Valve energized to deliver air fuel to    CENTRAL HEATING burner   75  F       Igniter de energized  
8. nformation    Address        
9. ture leaving boiler     Water Temperature entering boiler   DHW Thermostat  open or closed      Open   Hot water is satisfied    Boiler Status    Closed   DHW calling for heat      System Water Temperature  if used   Vent System Temperature  Outdoor Temperature  if used     Heat Exchanger Pump status  On or Off   H System Pump status  if used  On or Off         DHW Pump status  if used  On or Off        7                  7   un    SETTINGS  Central  Setpoint     F Y  Setting Range  104   F to 195   F  40   C to 91   C   Default Value  140   F  60   C     SETTINGS    DHW Setpoint    Senn Range  104   Fto 195   F  40   C to 91   C   Default Value  180   F  82   C     SETTINGS   Chanqge   Temperature Units  Fahrenheit     k       SETT INGS     Change  Language    Engl i  aaa Te    Adjust CH set point to hydronic system design while    Operating in CH Mode   0  CH with Thermostat  or 3   Permanent Demand      In CH Mode   1  CH with Thermostat and Outdoor Reset  or 2       CH with Full Outdoor Reset   Display will change to    OD Reset    Setpoint    and cannot be changed  Control Module calculates set    point based on outdoor temperature     DHW set point determines supply water temperature set point  when operating in DHW mode     Contact qualified agency to make changes     Select temperature unit of measure     Fahrenheit   F or Celsius   C     Select user interface language     English       BLE SHOOTIN    4   TR    12108  azas 0  Aduaby  JOYE 1In9419 19594 pajeng J2PeJuon
10. y       uonisod  NO u  SaydNMSsS zuolsod  JaMOd 43j10q  je ase    NO ul Jeygealq PNA Uew S        431109   saydyms Jamod     ioq  e y2ay5  AIDS 0  Anuaby       NO YUMS J8MOdg S         p  jileno 28u09                      S3A         NO Jajloq o  Jamod sj                   uonei  do  pue Buiyas sadoud 104   shelsouu  ul 434          UolI BuuioJul uoneJsdo J  jioq    ejdsip sseyajuj asn saog    131108  991A1OS 0  Aduaby  paeng 13e1uo5       oem JOH Onsawog   13108  10 Buneay jesjuey   Jmu     0    auaby    ejdsip ad epaju  sasn saog   paeng 19F1uoo       i     3 10113 Bumyoojg  JO   V wey noy207   Ae  ds  p soeyajuj sasn saog       5   MAINTENANCE    Asphyxiation hazard  Contact qualified agency if  condensate trap is not filled with water     FIGURE 5 1 Condensate Drain    I a   N a  Si ge    w             FLGURE 5 2 Safety Relief Valve Discharge Pipin                Safety Relief Valve    1          System System  Supply Return       Check Local Codes For Maximum  Distance To Floor    Perform general housekeeping and maintenance as  specified below     5 1 Continuous     Keep boiler area free from combustible materials   gasoline and other flammable vapors and liquids        Keep combustion air and vent terminations  outside  building  free from trash  vegetation and other items  capable of blocking flow     5 2 Monthly       Inspect combustion air  vent  and condensate drain  piping for deterioration  leaks or sagging  Contact  qualified agency  as necessary        Inspect 
    