Home

User Manual - ADFWeb.com

image

Contents

1. Industrial Electronic Devices User Manual Revision 2 020 English M Bus Ethernet Converter Order Code HD67030 B2 20 HD67030 B2 40 HD67030 B2 80 HD67030 B2 160 HD67030 B2 250 For Website information www adfweb com Product HD67030 For Price information www adfweb com Price HD67030 B2 20 www adfweb com Price HD67030 B2 40 www adfweb com Price HD67030 B2 80 www adfweb com Price HD67030 B2 160 www adfweb com Price HD67030 B2 250 Benefits and Main Features TCP UDP messages allowed Microprocessor for queue data control Temperature range 40 C 85 C 40 F 185 F User Manual ADFweb com Srl IT31010 Mareno Treviso User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 020 Page 1 of 22 For others M Bus products see also the following link Converter M Bus Master www adfweb com Product HD67021 RS232 www adfweb com Product HD67022 RS485 www adfweb com Product HD67024 USB M Bus Analyzer Scanner Sniffer www adfweb com Product HD67031 M Bus Isolator Repeater www adfweb com Product HD67032M Converter M Bus www adfweb com Product HD67029M 232 Modbus RTU on RS232 www adfweb com Product HD67029M 485 Modbus RTU on RS485 www adfweb com Product HD67044 Modbus TCP www adfweb com Product HD67051 B2 CANopen www adfweb com Product HD67053 PROFIBUS www adfweb com Product HD67056 BACnet www adfweb com Product HD67058 DeviceNet www ad
2. and open the new folder with the button Open Configuration SW67030 Open an Existing Configuration List of Avaliable Configurations Collaudo Examplel Example ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter Document code MN67030_ENG_ Revision 2 020 Page 13 of 22 Industrial Electronic Devices k SOFTWARE OPTIONS By pressing the Settings gt button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software S W6 70 3 0 Software Options Language Connection Options Selected Language SW67 030 Software Options Enable Internet Connection Check Software Update at Start of Program Check Available Update In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67030 check automatically if there are updatings when it is launched ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 020 Page 14 of 22 Industrial Electronic Devices SET COMMUNICATION By Pressing th
3. in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67030 the window below appears Fig 2 a Note a It is necessary to have installed Net Framework 4 SW67030 M Bus Ethernet Converter A Opened Configuration of the Converter Begin Examplel Step 1 gt New Configuration Open Configuration Step 2 gt Set Communication Step 3 aE Update Dewice aE Download Conf ee E F Figure 2 Main window for SW67030 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices Ne User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 020 Page 12 of 22 NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button creates the folder which contains the entire device s configuration SW67030 Create New Configuration Name of the new Configuration Example Kore A device s configuration can also be imported or exported To clone the configurations of a Programmable M Bus Ethernet Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another name
4. the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declaration is made by our company You can send an email to support adfweb com or give us a call if you need it ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 020 Page 4 of 22 Industrial Electronic Devices EXAMPLE OF CONNECTION M Bus MAC 10 64 E2 07 42 1F Serial Nr a Device state i pe le waw ADF web com M Bus Master Ethernet Converter 2 HD67030 B2 20 Dip Switch A ETHERNET G CALEA aaa D NEES f NEE oppga ONS HD67030 B2 xxx a Slave M Bus ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices Document code MN67030_
5. 568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable M BUS The M Bus is a unpolarized bus A two wire standard telephone cable JYStY N 2 0 8 mm is used as the transmission medium for the M Bus The maximum distance between a slave and the repeater is 350m this length corresponds to a cable resistance of up 299 This distance applies for the standard configuration having Baud rates between 300 and 9600 Baud and a maximum of 250 slaves The maximum distance can be increased by limiting the Baud rate and using fewer slaves but the bus voltage in the space state must at no point in a segment fall below 12V because of the remote powering of the slaves In the standard configuration the total cable length should not exceed 1000m in order to meet the requirement of a maximum cable capacitance of 180nF Taken from M Bus specifics ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 11 of 22 Industrial Electronic Devices USE OF COMPOSITOR SW67030 To configure the Converter use the available software that runs with Windows called SW67030 It is downloadable on the site www adfweb com and its operation is described
6. 91 31 AL Document code MN67030_ ENG Industrial Electronic Devices LEDS The device has got five LEDs that are used to give information of the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly 2 M Bus Comm yellow ri BUICK WAGEN FECEIVE M BUS Biiniks quickly Changes state when the reply to 3 M Bus Error yellow E ich E Blinks quickly 4 Ethernet Comm Changes state when receive a Blinks auicki yellow Ethernet frame q y ON Ethernet cable connected ON Ethernet cable connected 5 Ethernet Link green g OFF Ethernet cable disconnected OFF Ethernet cable disconnected Ledi Green Device state ed2 M Bus MAC 10 64 E2 07 42 1F Serial Nr C4367 4 Dee state t3 HD67030 B2 20 P bn Dip Switch A O ETHERNET Led4 Yellow Ethernet Comm ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com User Manual M Bus Ethernet Converter Revision 2 020 Page 9 of 22 Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 10 of 22 Industrial Electronic Devices ETHERNET The Ethernet connection must be made using Connector3 of HD67030 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T
7. C or 18 35V DC Temperature range 40 C to 85 C At the Converter can be connected up to 250 standard M Bus devices This number depends of the code expressed by the xxx number HD67030 B2 20 support up to 20 M Bus devices HD67030 B2 40 support up to 40 M Bus devices HD67030 B2 80 support up to 80 M Bus devices HD67030 B2 160 support up to 160 M Bus devices HD67030 B2 250 support up to 250 M Bus devices A In the case of HD67030 B2 160 the device must be mounted on 35mm DIN rail which is horizontally mounted on a wall or cabinet back plate To avoid obstructions to the airflow around the unit it is recommended to not cover the paths of air A In the case of HD67030 B2 250 the device must be mounted on 35mm DIN rail which is horizontally mounted on a wall or cabinet back plate This unit have a fan in the top of the enclosure To avoid obstructions to the airflow around the unit it is recommended to not cover the paths of air Take care to not cover the fan It is recommended to put the device into a ventilated cabinet ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 7 of 22 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 15 21V AC and 18 35V DC The consumption depends to the code of the device For more details see the two tables below Consum
8. ENG User Manual M Bus Ethernet Converter Revision 2 020 Page 5 of 22 CONNECTION SCHEME Dip Switch A Dipi Functioning Mode Normal Mode Boot Mode Dip2 Must be at ON 1 0000000000 Power Supply M Bus MAC 10 64 E2 07 42 1F gt OV W serial Nr C4367 121 at eT LED et om Dip Switch A Connectori Power Supply OV V OV Ground V Positive wire VAC min 15V max 21V V DC min 18V max 35V Figure 1 Connection scheme for HD67030 B2 xxx ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 6 of 22 Industrial Electronic Devices CHARACTERISTICS The HD67030 B2 xxx is Converter M Bus from to Ethernet line The control by microprocessor with 32 bits makes it particularly suitable for supervisor software and the connection to a Personal Computer The product allows to use an existent M Bus program or allows to create an own program It is necessary only to write the M Bus frames on Ethernet and then receive the reply For information about M Bus see the link www m bus com The M Bus Ethernet Converter allows the following characteristics Electrical isolation between Ethernet and M Bus Baud Rate and Parity changeable with software Mountable on Rail DIN Power Supply 15 21V A
9. cial functions with the device the possibility to send a PING in the a ha network to a specific device and the possibility to open a TCP connection a ee eee For sending a PING is necessary to check the field Enable Ping Command then is possible to select E iene when send the PING Type in the field Ping Type 192 16 0 Forever when is necessary to send a PING continuously cee Until response the PING is sent until a reply is received by the device Cancel Number PINGs the PING is sent for the number of times expressed in the field below the command Fig 3 Set Communication window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 15 of 22 Industrial Electronic Devices In the field PING Time Seconds is necessary to specify the interval time between to requests This time can be set from 1 to 65535 seconds This time is used by all types of PING In the field PING IP Address is necessary to insert the IP address of the device that the PING is addressed to If the Client cannot open the connection to the HD67030 B2 when using TCP is possible to configure the HD67030 B2 to open the connection to the client For doing this is necessary to check the field Enable Open Connection TCP then insert the IP of the Client in the f
10. e Set Communication button from the main window for SW67030 Fig 2 the window 2W67030 Set Communication appears Fig 3 Pe Baudrate 2400 The window is divided in two section one for the parameters of M Bus line and the other for the parameters of Ethernet Fars a TimeOut Use M Bus Specifics The means of the fields for M Bus are TimeOut Value 1000 Inthe field Baudrate it is possible to select the baudrate of the M Bus line Inthe field Parity it is possible to select the parity of the line aca In the field TimeOut there is the possibility to set the M Bus TimeOut There are two ways wee o By selecting the field Use M Bus Specifics the value is the default one calculated with this formula 330000 Baudrate 50 ms ee o By selecting Manual Value is possible to insert in the value expressed in milliseconds _ manually C GATEWAY 192 168 The parameters of Ethernet are Port 10001 IP address where is specified the IP address assigned to the device SubNet Mask where is specified SubNet Mask where the device is located In the field Gateway insert the IP address used for going out of the net For enable it the you must check the field Gateway In the field Port insert the number of port Ping Time Seconds 1 Enable Ping Command Ping Type Forever Number Pings D Ping IF ADDRESS There is the possibility to use two spe
11. e 39 0438 30 91 31 Fax 39 0438 49 20 99 m www adfweb com ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31
12. ent code MN67030_ENG Revision 2 020 Page 18 of 22 Industrial Electronic Devices DOWNLOAD CONF By pressing the Download Conf button it is possible to download the Configuration that is inside the device into the opened project If you don t know the actual IP address of the device you have to use this procedure Turn off the Device Put Dipl of Dip Switch A at ON position SW670 30 i Download Configuration from Etherner UDP Turn on the device Connect the Ethernet ca ble Insert the IP Address of HD67030 Insert the IP 192 168 0 88 192 iss 2 189 Press the Ping button must appear Device Found ee a ene ee ae eee Press the Next button ing Press the Execute update firmware button to start the download When all the operations are OK turn off the Device a Execute update firmware Put Dipl of Dip Switch A at OFF position Turn on the device At this point the configuration of the device is correctly downloaded 0 Do you want to overvrite the current configuration If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found i E aot Se nes Press the Next button FIRMWARE Not Used Press the Execute update f
13. fweb com Product HD67077 EtherNet IP www adfweb com Product HD67078 PROFINET M Bus Concentrator Datalogger www adfweb com Product HD67054M www adfweb com Product HD67057 B2 XxXX M Bus Slave Modbus Master Converter www adfweb com Product HD67059M 232 Do you have an your customer protocol www adfweb com Product HD67003 INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 2 of 22 Industrial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INDEX UPDATED DOCUMENTATION age Dear customer we thank you for your attention and we remind you that INDEX 2 you need to check that the following document is UPDATED DOCUMENTATION 2 Updated REVISION LIST 2 Related to the product you own WARNING 2 TRADEMARKS 2 To obtain the most recently updated document note the document code SECURITY ALERT 3 that appears at the top right hand corner of each page of this document EXAMPLE OF CONNECTION 4 l CONNECTION SCHEME 5 With this Document Code go to web page www adfweb com download CHARACTERISTICS 6 and search for the corresponding code on the page Click on the proper Document Code and download the updates POWER SUPPLY 7 FUNCTION MODES 8 LEDS 9 REVISION LIST ETHERNET 10 M BUS 10 Revision Date Author Chapter Description USE OF COMPOSITOR SW67030 11 2 000 01 08 2012 Fl All New
14. hardware version 2 010 03 12 2012 Fl All Software changed v1 500 Se ae A PCA CONPICU REICH 2 011 29 03 2013 FI All Added new chapters SET COMMUNICATION 14 2 020 13 05 2015 FI All Software changed v2 000 UPDATE DEVICE 16 DOWNLOD CONF 18 WARNING MECHANICAL DIMENSIONS 19 ORDER CODE 20 ADFweb com reserves the right to change information in this manual about ACCESSORIES 20 our product without warning DISCLAIMER 21 ADFweb com is not responsible for any error this manual may contain OTHER REGULATIONS AND STANDARDS 21 WARRANTIES AND TECHNICAL SUPPORT 22 TRADEMARKS RETURN POLICY 22 PRODUCTS AND RELATED DOCUMENTS 22 All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 3 of 22 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and Safety regulation are required for each individual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with
15. ield IP Destination and in the field Port Destination the Port used for the communication K Note a This functionality is only available for TCP connections l K Note a If the Client closes the connection automatically the HD67030 B2 tries to reopen it at regular intervals K Note a For the HD67030 B2 there isn t the selection of TCP or UDP for the Ethernet communication both are available at the same ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices UPDATE DEVICE By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if necessary If you don t know the actual IP address of the device you have to use this procedure 7 Turn off the Device Put Dip1 of Dip Switch A at ON position Turn on the device Connect the Ethernet cable Insert the IP 192 168 0 88 Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dip1 of Dip Switch A at OFF position Turn on the device At this point the configuration firmware on the device is correctly updated If you know the actual IP address of
16. in this document can be modified without notice The content of the document is a under continual renewal For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate ys collection systems m This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it Should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the
17. irmware button to start the upload a ee ee When all the operations are OK the device automatically goes at Normal Mode At this point the configuration of the device is correctly downloaded Figure 6 Download Conf windows ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 19 of 22 Industrial Electronic Devices MECHANICAL DIMENSIONS CO000008O86000 Power Supply M Bus MAC 10 64 E2 07 42 1F OY W Serial Mr C4367 15 21 ac O n LEO m IB 3S 0 paS AUF ESR 95 mm 3 74 inch 71 mm 2 19 inch Housing PVC Weight 200g Approx Figure 7 Mechanical dimensions scheme for HD67030 B2 xxx ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 20 of 22 Industrial Electronic Devices ORDERING INFORMATIONS The ordering part number is formed by a valid combination of the following HD67030 B 2 xxx L Maximum number of slaves supported 20 up to 20 standard slaves 1 5mA consumption connected to M Bus 40 up to 40 standard slaves 1 5mA consumption connected to M Bus 80 up to 80 standard slaves 1 5mA consumption connected to M Bus 160 up to 160 standard slaves 1 5mA consumption connected
18. ption at 24V DC beie No Load W VA Full Load W VA This value is with all the Slave M Bus devices of the code 20 40 80 160 250 connected to the line Caution Not reverse the polarity power a Connectori Power Supply OV Ground W Positive wire lV AC min 15V max 21V VDC min 18V max 35V HD67030M B2 xxx ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 8 of 22 Industrial Electronic Devices FUNCTION MODES The device has got two functions mode depending of the position of the Dip1 of Dip Switch A of HD67030 B2 xxx The first with Dipi of Dip Switch A at OFF position is used for the normal working of the device The second with Dipi of Dip Switch A at ON position is used for upload the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section Dip Switch A Dipi Functioning Mode Normal Mode Boot Made Dip2 Must be at A Warning Dip2 of Dip Switch A must be at ON position for working even if the Ethernet cable isn t inserted ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30
19. the device you have to use this procedure 4 t 4 Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode Figure 4 Update device windows ADFweb com Srl IT31010 Mareno Treviso User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 020 Page 16 of 22 SW67 030 Update Firmware from Etherner UDP Insert the IP Address of HD67030 sz fis fo 50 Check the Connection the device SW67 030 Update Firmware from Etherner UDP Update Device Options Firmware Read Firmware when finish Configuration Read Configuration when finish kia Execute update firmware INIT Waiting Ver 1 003 FIRMWARE Waiting PROJECT Waiting INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 020 Page 17 of 22 Industrial Electronic Devices At this point the configuration firmware on the device is correctly updated Note lt lt When you install a new version of the software if it is the first time it is better
20. to M Bus 250 up to 250 standard slaves 1 5mA consumption connected to M Bus Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M DIN Rail mounting Device Family HD67030 M Bus Master Ethernet Converter Order Code HD67030 B2 20 Converter M Bus Master Ethernet up to 20 slaves connected to M Bus Order Code HD67030 B2 40 Converter M Bus Master Ethernet up to 40 slaves connected to M Bus Order Code HD67030 B2 80 Converter M Bus Master Ethernet up to 80 slaves connected to M Bus Order Code HD67030 B2 160 Converter M Bus Master Ethernet up to 160 slaves connected to M Bus Order Code HD67030 B2 250 Converter M Bus Master Ethernet up to 250 slaves connected to M Bus ACCESSORIES Order Code APWO20 Power Supply for M Bus Master device that supports up to 20 Slaves Order Code APWO40 Power Supply for M Bus Master device that supports up to 40 Slaves Order Code APWO8O Power Supply for M Bus Master device that supports up to 80 Slaves Order Code APW160 Power Supply for M Bus Master device that supports up to 160 Slaves Order Code APW250 Power Supply for M Bus Master device that supports up to 250 Slaves ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Document code MN67030_ENG Revision 2 020 Page 21 of 22 Industrial Electronic Devices DISCLAIMER All technical content with
21. use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING The product conforms with the essential requirements of the applicable EC directives ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 020 Page 22 of 22 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 a IT 31010 Mareno di Piave TREVISO Italy Phon
22. you do the update of the Firmware in the HD67030 B2 xxx device J Note When you receive the device for the first time you also have to update the Firmware in the HD67030 B2 xxx device A Warning If the Fig 5 appears when you try to do the Update try these points before seeking assistance Try to repeat the operations for the update Try with another PC Try to restart the PC saa haa laa If you are using the program inside a Virtual Machine try to use in the main FIRMWARE PROTECTION Operating System If you are using Windows Seven or Vista or 8 make sure that you have the administrator privileges Take attention at Firewall lock Check the LAN settings Ver 1 003 PROJECT PROTECTION Figure 5 Protection window di In the case of HD67030 B2 xxx you have to use the software SW67030 www adfweb com download filefold SW67030 zip Note lt To download the old version of the manual the one where is present only the HD67030M device please follow this link www adfweb com download filefold Adapter M Bus to Ethernet MN67030 ENG pdf Note e da To download the old version of the software the one where is possible to update the HD67030M please follow this link www adfweb com download filefold SW67030 1 201 zip ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter AL Docum

Download Pdf Manuals

image

Related Search

Related Contents

Owner`s Manual    Samsung SGH-D500 Felhasználói kézikönyv  A composer`s guide to the Fokker organ by Ere Lievonen version 4.9  ASUS HUG7510 User's Manual  Control por Modbus sobre TCP/IP    User Manual  W B Marvin AWS1537 Instructions / Assembly  File - Servicing all your beverage needs since 1988  

Copyright © All rights reserved.
Failed to retrieve file