Home
SoundPatrol DP with Printer Sound Level Meter User Manual
Contents
1. 8 6 dBA Lavg er5 43 9 dBA SPLmin 41 1 dBA Runtime 19 Sec Date Time Location By Step 8 Turn OFF the printer and the SoundPatrol Depressing and holding the power button for about 3 seconds turns OFF the printer The Green LED will turn off when the printer is OFF Moving the center switch to the OFF position turns OFF The SoundPatrol Step 9 Removing the cable For your convenience the 3 5 mm connector at the bottom of the SoundPatrol may be unplugged or re plugged at any time The Flat style connector on the side of the thermal printer has a latch release that must be pushed to release the connector Place your thumb on the backside of the printer connector depress the release latch and pull straight out Replacement Parts 057 340 Serial Thermal Printer FTP628WSL 057 258 5 pack Thermal Paper 58mm x 36mm x 15m 057 341 Sound Patrol Fujitsu Serial Printer Cable 1m Dip Switch Settings for thermal printer located on side next to RS232C port Switch Setting P RS232C Interface On QUEST TECHNOLOGIES now part of 3M
2. SoundPatrol DP 1200 2200 amp Portable Thermal Printer s ca a a wa Quest Technologies a 3M company is a manufacturer of durable reliable instrumentation and software systems that help monitor a variety of health and safety hazards including noise vibration heat stress indoor air quality and toxic combustible gases The 3M Quest brand of instrumentation is used by safety and industrial hygiene professionals to help comply with worker safety and environmental regulations and standards around the world Quest Technologies a 3M company is part of the 3M Occupational Health amp Environmental Safety Division a global leader in respiratory hearing eye head and fall protection visibility and protective clothing and detection products To learn more call us at 262 567 9157 or visit www questtechnologies com 057 245 Rev E 7 11 Using the SoundPatrol DP 1200 2200 with the Portable Thermal Printer Instructions Scope The following instructions detail the added SoundPatrol with the portable thermal printer p n 057 340 Type FTP628 For other basic operating instructions use this in combination with the 1200 2200 user manual part number 056 653 Manual Details http www questtechnologies com Assets Documents SoundPatrol_ manual pdf The 1200 2200 Sound level meter includes three printouts on the portable thermal printer which includes a cali
3. bration report enforcement report with summary data and a continuous data report Please Note the AC DC out functions of the connector have been disabled and the connector is used as the serial output for the printer Before using the printer for the first time set the dip switches using the dip switch settings listed at the end of these instructions Step 1 Connect the cable The SP Fuji cable 057 341 is provided with the unit and printer The 3 5 mm connector is fully inserted into the receptacle at the bottom of the SoundPatrol Insert the flat style connector into the side of the thermal printer port labeled RS 232C Note that it fits only one way and the latch release will be towards the backside of the printer The latch release helps to secure the connector and is used when removing Step 2 Turn ON the printer and the SoundPatrol The printer is turned ON by depressing and holding the power button for about 1 second Note refer to the portable thermal printer manual to power on with either AC DC power adapter or insert Li ion battery A green LED blinks when the printer is ready Moving the center switch from the OFF to the PAUSE or RUN position turns ON the SoundPatrol Step 3 RESETTING the SoundPatrol Between measurements you must always remember to push and hold the RESET button for more than 3 seconds to clear out the previous integrating measurement values NOTE The LEQ meas
4. to stabilize and then move the switch back to the PAUSE position Step 6 Optional Print the Enforcement Report Depress the PRINT RESET button down for about 1 second When you release it the printer will print the enforcement report When the report is finished in a few seconds you may print more copies by pressing the PRINT RESET button again for about 1 second Enforcement Report with summary data example Quest SoundPatrol DP 3 3 Heading amp Version L200 s n SPEOS52134 Model amp Serial Number TResponse FAST RESPONSE Setting SPLmax 90 8 dBA SPLmax Measurement with WEIGHTING Lavg erd 65 2 dBA Lavg er5 or LEQ with WEIGHTING SPLmin 43 9 dBA Runtime 10 Sec Date Time Location By Step 7 Optional Print Continuous Report When the unit is in RUN you can depress the PRINT RESET button down for about 1 second When you release it the printer will print the Continuous report Each second a new line will be printed The printout ends when the switch is moved from RUN to PAUSE Continuous Data Report example TResponse FAST The header shows the Settings time SPL Lavg ER x Weight A 10 42 1 43 3 Seconds 1 Second SPL amp Lavg Li A244 43 43 Ah Si Ly Asb e AAs 1 5 13 42 1 14 42 0 Loy 42 2 42 16 57 0 43 17 47 2 43 Quest SoundPatrol DP 3 3 1200 s n SPE052134 TResponse FAST SPLmax 5
5. urement is also automatically reset whenever the RANGE WEIGHTING or RESPONSE switches are changed Step 4 Suggested Once daily Calibration Report Turn on the Calibrator Position the calibrator and adapter over the microphone Depress the CAL button on the SoundPatrol When the calibration has successfully completed a complete calibration report will be printed If there is a calibration failure a partial report will appear with a NOCAL error printed at the end Refer to the Quest 056 653 manual for more specific calibration and setup instructions Quest SoundPatrol DP 3 3 Heading amp Version T200 37m SPEOS2134 Model amp Serial Number TResponse FAST RESPONSE Setting TODAY S CALIBRATION Values with WEIGHTING Old SPL 114 2 dBA old reading with calibrator Ref Level 114 0 dBA Calibration set point new SPL 114 0 dBA new reading after cal Date Time Step 5 Collect the integrating measurement Select settings to match your local enforcement rules Typical US settings may include 3 dB Exchange Rate 50 120 dB Slow A Weighted LEQ The enforcement report is designed to show SPLmax SPLmin and either Lavg or Leq These readings are generated ONLY after the unit has been placed into the RUN mode for at least one second When the noise of interest is the appropriate distance from the meter move the center switch to the RUN position Allow the LEQ reading
Download Pdf Manuals
Related Search
Related Contents
パワーコンディショナ AESOP Phone System Instructions for Employees RCM 310 Blaupunkt ALBERTVILLE DJ User's Manual 祐子は - あなたとは誰か? 何故ここに居るのか? この世界とは何か? FP7 High-speed Counter Unit User`s Manual User Manual TDS 200-Series Digital Real Notice: OMRON Product References Visual Aids 2010 Nissan Frontier Owner Guide - French Copyright © All rights reserved.