1. 5 95 RH Non condensing For discontinuous vibration Amplitude 57 lt fs150Hz 9 8m s 1G Los 2 For continuous vibration times in IEC 61131 2 Frequency Acceleration Amplitude X Y Z 10 lt f lt 57Hz 0 035mm directions 57 lt f lt 150Hz 4 omis 05c Max impact acceleration 147ms 15G Each 10 5 Vibration Authorized time 11ms Shocks IEC 61131 2 Pulse wave Sign half wave pulse Each 3 times in X Y Z directions Square wave impulse noise 1 500V a Voltage 4kV IEC 61131 2 Electrostatic discharging contact discharging IEC 610004 2 Radiated electromagnetic IEC 61131 2 27 500MHz 10 V m field noise IEC 610004 3 Fast Power Digital Analog I O Transient module communication interface IEC 61131 2 burst IEC 61000 4 4 Voltage 2kV noise No corrosive gas or dust Ambient conditions Operating 2000m or less height 11 Cooling method Self cooling Performance specifications of Analog Input Module are as specified in Table Specifications Voltage Input Current Input DC1 5V DCO 5V DCO 10V DC 10 10 V Input Resistance 1 MQ min DC 4 20 mA DC 0 20 mA Input Resistance 250 Q Analog input gt Current input or Voltage input can be selected through the external switch Analog input gt Analog input range can be selected through user program or I O parameter range setting gt Respective input ranges can be s
2. gt Do not drop or insert any metallic object into the product Risk of fire electric shock and malfunction gt Do not charge heat short solder and break up the battery Risk of injury and fire by explosion and ignition Before wiring the PLC ensure to check the rated voltage and terminal arrangement for the module and observe them correctly Risk of electric shock fire and malfunction Tighten up the terminal screw firmly to defined torque when to wire the PLC Risk of fire and electric shock if the terminal screw looses Use the PLC in an environment that meets the general specifications contained In this datasheet Risk of electrical shock fire erroneous operation and deterioration of the PLC Be sure that external load does not exceed the rating of output module Risk of fire and erroneous operation Do not use the PLC in the environment of direct vibration Risk of electrical shock fire and erroneous operation Do not disassemble repair or modify the PLC Risk of electrical shock fire and erroneous operation When disposing of PLC and battery treat it as industrial waste Risk of poisonous pollution or explosion Precautions for use gt Do not install in any places other than PLC controlled place gt Ensure that the FG terminal is grounded with class 3 grounding which is dedicated to the PLC Otherwise it may cause disorder or malfunction of PLC lt Best gt i gt Connect expansion connector c
3. 5 V or 4 20 mA CH1 disconnection flag 1 5 V or 4 20 mA CH2 disconnection flag 1 5 V or 4 20 mA CH3 disconnection flag 1 5 V or 4 20 mA CH4 disconnection flag 1 5 V or 4 20 mA CH5 disconnection flag 1 5 V or 4 20 mA CH6 disconnection flag 1 5 V or 4 20 mA CH7 disconnection flag 1 5 V or 4 20 mA CH8 disconnection flag 1 5 V or 4 20 mA CH9 disconnection flag 1 5 V or 4 20 mA CH10 disconnection flag 1 5 V or 4 20 mA CH11 disconnection flag 1 5 V or 4 20 mA CH12 disconnection flag 1 5 V or 4 20 mA CH13 disconnection flag 1 5 V or 4 20 mA _xy_CH14_IDD CH14 disconnection flag 1 5 V or 4 20 mA _xy_CH15_IDD CH15 disconnection flag 1 5 V or 4 20 mA Uxy 11 0 _xy_ERR_CLR Flag to request error clear Remark How to use U device Uxy 00 0 Base No t ae Word No Slot No Ex1 When reading CHO Active bit of Base 1 Slot 6 gt U16 01 0 Ex2 When reading CHO Active bit of Base 0 Slot 11 gt U0B 01 0 Unit mm 2MLF AD16A CO T O LAUL M
4. and allowable current whose size is not less than the max cable standard of AWG22 0 3mm c Do not place the cable too close to hot device and material or in direct contact with oil for long which will cause damage or abnormal operation due to short circuit d Check the polarity when wiring the terminal e Wiring with high voltage line or power line may produce inductive hindrance causing abnormal operation or defect 2 Wiring Example a Voltage input CHO th A ni _ O n H15 e b Current input eS 1 Use the cable of 2 core twisted shield AWG 22 is recommended for the cable standard 2 Current input resistance is 250 Q typ 3 Voltage input resistance is 1 MQ min 4 FG means PLC system s FG Analog Input Module s operation parameters can be specified through XG5000 s I O parameters 1 Channel RUN STOP setting Select Enable or Disable for each channel 2 Input Voltage Current range setting Select the range of analog input as desired 2MLF AD16A provides 4 Voltage input ranges and 2 Current input ranges a Voltage input range 0 5V 1 5V 0 10V 10 10V b Current input range O 20mA 4 20mA 3 Output data format setting Select the type of output data 4 output data formats are provided in this module Unsigned value Signed value Precise value Percentile value 4 A D conversion methods a Sampling processing Sampling process will be performed if A
5. D conversion type is not specified b Filter processing 1 99 Used to delay the sudden change of input value c Average processing Outputs average A D conversion value based on frequency or time 1 Time average processing 16 16000 ms 2 Count average processing 2 64000 times Device Global variables R W ML200 ML200 IEC fies am tects e Uxy 00 F _xy_RDY Module READY flag _xy_CHO_ACT CHO Run flag _xy_CH1_ACT CH1 Run flag _xy_CH2_ACT CH2 Run flag _xy_CH3_ACT CH3 Run flag _xy_CH4_ACT CH4 Run flag _xy_CH5 ACT CH5 Run flag _xy_CH6_ACT CH6 Run flag _xy_CH7_ACT CH7 Run flag _xy_CH8_ ACT CH8 Run flag _xy_CH9_ACT CH9 Run flag _xy_CH10_ACT CH10 Run flag _xy_CH11_ACT CH11 Run flag _xy_CH12_ACT CH12 Run flag _xy_CH13_ACT CH13 Run flag _xy_CH14_ACT CH14 Run flag _xy_CH15 ACT CH15 Run flag Uxy 01 F 7 Uxy 10 _xy_CH7_DATA CH8 digital output value R Uxy 11 _xy_CH7_DATA CH9 digital output value R Uxy 12 _xy_CH7_DATA CH10 digital output value R Uxy 13_ _xy CH7_DATA _CH11 digital output value R Uxy 14 xy CH7_DATA _ CH12 digital output value R Uxy 15 _xy_CH7_DATA _ CH13 digital output value R Uxy 16 _xy_CH7_DATA CH14 digital output value R Uxy 17 _xy_CH7_DATA CH15 digital output value R _xy_CHO_IDD _xy_CH1_IDD _xy_CH2_IDD _xy_CH3_IDD _xy_CH4_IDD _xy_CH5_IDD _xy_CH6_IDD _xy_CH7_IDD _xy_CH8_IDD _xy_CH9_IDD _xy_CH10_IDD _xy_CH11_IDD _xy_CH12_IDD _xy_CH13_IDD CHO disconnection flag 1
6. Honeywell DATASHEET MasterLogic 200 AD Conver 2MLF AD16A 10310000929 Printed in Korea For more information on MasterLogic PLCs contact your nearest Honeywell office Australia Honeywell Ltd Phone 61 2 9353 4500 Fax 61 2 9353 7677 China Honeywell Tianjin Ltd Beijing Phone 86 10 8458 3280 Fax 86 10 8458 3102 Honeywell Tianjin Ltd Shanghai Phone 86 21 6237 0237 Fax 86 21 6237 3102 Indonesia PT Honeywell Indonesia Phone 62 21 535 8833 Fax 62 21 5367 1008 India Honeywell Automation India Ltd Phone 91 20 5603 9400 Fax 91 20 5603 9800 Honeywell Co Ltd Japan Honeywell Inc Phone 81 3 5440 1395 Fax 81 3 5440 1368 South Korea Honeywell Co Ltd Phone 82 2 799 6114 Fax 82 2 792 9015 Malaysia Honeywell Engineering Sdn Bhd Phone 603 7958 4988 Fax 603 7958 8922 New Zealand Honeywell Ltd Phone 64 9 623 5050 Fax 64 9 623 5060 Philippines Honeywell Systems Inc Phone 63 2 633 2830 Fax 63 2 638 4013 Honeywell Process Solutions 17F Kukje Center Building 191 Hangangro 2ga Yongsan gu Seoul 140 702 Korea Tel 82 2 799 6114 Fax 82 2 792 9015 Email MasterLogic_support Honeywell com 10310000929 Printed in Korea Singapore Honeywell Pte Ltd Phone 65 6355 2828 Fax 65 6445 3033 Thailand Honeywell Systems Ltd Phone 662 693 3099 Fax 662 693 3085 Taiwan Honeywell Tai
7. alog input value when digitalized value is 0 in case that the range of digitalized value is O 16000 3 Gain Value Analog input value when digitalized value is 16000 in case that the range of digitalized value is O 16000 4 When Analog Input Module is released from the factory Voltage Current selecting switch is adjusted for current input type which is available for user to change Parts names of functions are as described below 2MLF AD16A SOUL WYr oO pmo name eseriptons O gt Displays the operation status of 2MLF AD16A RUN LED on Operation normal Blinks Error occurs Off DC 5V disconnected module error gt Analog input terminal whose respective channels can be connected Terminal with external devices Current Voltage selecting switch gt Switch for selecting Voltage input and Current input a b c d Do not drop or give impact on the product Do not detach PCB from the case it may cause malfunction During wiring or other work do not allow any wire chips get inside the product Switch off the external power before mounting or removing the module and the cable Sr S No 1 Precautions for wiring a Do not place AC power line near to the module s external input signal line It should be farther than minimum 100mm between both lines in order not to be affected by noise and magnetic field b Cable shall be selected in due consideration of ambient temperature
8. et based on channels 1 Voltage Input Analog input 1 5V 0 5V 0 10V 10 10V Digital output Unsigned Value 0 16000 Signed Value 8000 8000 1000 5000 0 5000 0 10000 10000 10000 Percentile Value 0 10000 2 Current Input Analog input Digital output Unsigned Value 0 16000 Signed Value 8000 8000 4000 20000 0 20000 Percentile Value 0 10000 gt 16 bit binary value data 14 bits Digital output 4 20mA 0 20mA gt Format of digital output data can be set through user program or S W package respectively based on channels Analog input Resolution range 1 16000 range 0 250 oN 0 3125 m 0 625 mV Resolution 1 16000 Analog input The max resolution 0 2 or less when ambient temperature is 25 C 5 Accuracy 0 3 or less when ambient temperature is 0 C 55 Max conversion 500 us channel speed Absolute max 15V 30 mA input Analog 16 channels input points Photo coupler insulation between input terminal and PLC power Insulation method no insulation between channels Terminal 32 point terminal connected I O points Fixed point assignment 64 Variable point assignment 16 occupied Internal consumed current Weight 115g 1 When Analog Input Module is released from the factory Offset Gain value is adjusted for respective analog input ranges which is unavailable for user to change 2 Offset Value An
9. orrectly when expansion modules are needed gt Do not detach PCB from the case of the module and do not modify the module gt Turn off the power when attaching or detaching module gt Cellular phone or walkie talkie should be farther than 30cm from the PLC gt Input signal and communication line should be farther than minimum 100mm from a high tension line and a power line in order not to be affected by noise and magnetic field Before handling the product Before using the product read the datasheet and the User s manual through to the end carefully in order to use the product efficiently MasterLogic 200 User s Manual po ame ote 10310000512 MasterLogic 200 User s manual Programming software MasterLogic 2001 200R User s manual Programming software 10310000834 10310000510 MasterLogic 200 Basic Instruction amp Programming User s manual MasterLogic 2001 200R Basic Instruction amp Programming User s 10310000833 manual Analog Input Module designed for MasterLogic 200 series is used to convert analog signal voltage or current input to the digital value of 16 bit binary data data 14 bits specified in MasterLogic 200 CPU modules General specifications of MasterLogic 200 series are as specified in Table Related Specifications specifications 1 Operating temp 0 C 55 C Storage temp 25 70 C 5 95 RH Non condensing Operating 3 humidity Storage 4 humidity
10. wan Ltd Phone 886 2 2245 1000 Fax 886 2 2245 3241 For Countries SE Asia Listed below call Honeywell Singapore Office Pakistan Cambodia Laos Myanmar Vietnam and East Timor For Countries Listed below call Honeywell India Office Bangladesh Nepal and Sri Lanka Honeywell Safety Precautions gt Safety Precautions is for using the product safe and correct in order to prevent the accidents and danger so always follow the instructions gt The precautions explained here only apply to the 2MLF AD16A unit For safety precautions on the PLC system refer to the MasterLogic 200 2001 200R CPU User s manual gt The precautions are divided into 2 sections Warning and Caution Each of the meanings is represented as follows Wa rning If violated instructions it may cause death fatal injury or considerable loss of property Caution If violated instructions it may cause a slight injury or slight loss of products gt The symbols which are indicated in the PLC and User s Manual mean as follows aS Gives warnings and cautions to prevent from risk of injury fire or malfunction Gives warnings and cautions to prevent from risk of electrical shock gt Store this datasheet in a safe place so that you can take out and read whenever necessary Always forward it to the end user AN Warning gt Do not contact the terminals while the power is applied Risk of electric shock and malfunction