Home
MODEL NUMBER: USER MANUAL
Contents
1. Once air pressure reaches preset cut out pressure of your pressure switch 165 PSI cut on 200 PSI cut off the compressor will shut off automatically Inspect all air line connections for leaks with soap and water solution If a leak is detected the air line may not be cut squarely or pushed all the way in Tighten connections if needed OPERATING INSTRUCTIONS IMPORTANT Always operate the compressor BELOW the MAXIMUM PRESSURE RATING of the compressor Please refer to Application amp Specifications Sections of this manual for details Always observe the MAXIMUM DUTY CYCLE of the air compressor Refer to Compressor Applications and Specifications Section of this manual for details Operation exceeding maximum pressure ratings and or duty cycle will result in damage to air compressor Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR This feature is designed to protect the air compressor from overheating causing permanent damage to your air compressor The thermal overload protector will automatically cut off power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use Should at any time during use your air compressor automatically shuts off do not attempt to restart air compressor Turn power switch to the air compressor to the OFF position The automatic thermal overload protector will automatically reset when int
2. Your Vital Air Source MODEL NUMBER 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2 0 Gallon 200 PSI Air Tank IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE ji ce Your vital Ar Sour USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION To reduce risk of electrical shock or Electrocution Do not disassemble Do not attempt repairs or modifications Refer to qualified service agencies for all service and repairs Do not use this product in or area where it can fall or be pulled into water or other liquids Do not reach for this product if it has fallen into liquid Use this compressor with 12 volt DC systems only This product should never be left unattended during use WARNING To prevent injuries Never allow children to operate this compressor Close supervision is necessary when this compressor is being used near children This compressor will become very hot during and immediately after use Do not touch any part of this compressor with bare hands other than the ON OFF switch during and immediately after use Do not use this product near flames or explosive materials or where aerosol products are being used Do not operate this product where oxygen is being administered Do not pump anything other than atmospheric air Never use this product wh
3. PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE
4. the compressor will overheat The compressor is moisture amp splash resistant but NOT WATERPROOF Do not mount air source kit in locations where the unit is likely to come in contact with water If it is necessary to mount the air compressor further away from the battery such as inside your vehicle or in the bed of your pickup use a minimum 8 AWG positive lead wire for remote installation Do not mount air source kit near areas where flammable liquids are stored MOUNTING AND WIRING Disconnect ground cable from vehicle s battery Temporarily position the air source kit in the location where it will be mounted Route ground wire to the negative post of the battery or to an appropriate grounding point and cut ground wire to length as needed Mount air source kit at tank leg mounts with the four grommets and four sets of bolts nuts washers and locking washers provided Route air line to the 1 2 inch compression fitting and make your air line connection Tighten compression fitting nut securely using a wrench Connect ground Black wire to a clean ground preferably a chassis ground and secure with a self tapping screw Connect positive Red lead wire from pre installed pressure switch to a fuse holder 20 amp minimum Once the kit is properly fused as close as possible to the power source connect and test compressor system by running the compressor for a short time to build up pressure in your air tank
5. to 5 years from date air tank was first used or use the date of manufacture as reference Your adherence to air tank draining guidelines will determine the replacement date of your air tank RUSTED TANKS CAN FAIL CAUSING EXPLOSIONS OR FATAL INJURIES Discard tank immediately if tank is rusted NOTE When using a safety pressure relief valve point the safety pressure relief valve away from your body Use the pull ring on the safety relief valve open the relief valve to vent any pressure inside the tank before attempting to service tank About Compressor Duty Cycle Compressor Duty Cycle refers to amount of time a compressor can be operated in a given time period at 100 PSI and at a standard ambient temperature of 72 F Duty Cycle is commonly expressed in percentile as Compressor On Time Compressor On Time Off Time As an example a compressor that is rated for 25 duty cycle means that compressor can be operated at 100 PSI 72 F for 10 minutes ON and 30 minutes OFF 10 min On 10 min On 30 min Off 10 min 40 min 25 Duty Cycle DUTY CYCLE REFERENCE CHART 100PSI 72 F About Rated Working Pressure To ensure trouble free service life of your compressor always operate compressor within rated working pressure of the compressor Never use a pressure switch with a higher cut off pressure than compressor s rated working pressure COMPRESSOR SPECIFICATIONS 480C Air Compressor Motor Voltage 12 Vo
6. ernal temperature of the air compressor drops below safe levels After allowing air compressor to cool off for about 30 minutes you can safely resume use of the air compressor by turning on the air compressor To prevent discharge of your vehicle s battery we strongly recommend that you keep the vehicle s engine running while using the air compressor Compressor performance is enhanced when operating compressor with vehicle s engine running IMPORTANT ONLY OPERATE THE AIR COMPRESSOR IN WELL VENTILATED AREAS AIR TANK PRECAUTIONS IMPORTANT a The air source kit air tank is rated for 200 PSI maximum working pressure Do not overfill Overfilling may result in death or serious injury Tank is not to be used as a breathing device Always wear ANSI approved safety glasses when operating air tank Bleed pressure from tank after each use and before servicing or adding attachments DRAIN TANK OFTEN TO REMOVE CONDENSATE FAILURE TO DRAIN TANK WILL ALLOW TANK TO RUST INTERNALLY a To remove any accumulated condensation inside the tank bleed pressure from tank until pressure is approximately 5 PSI to 20 PSI Drain water from tank by opening the drain cock valve If drain cock is plugged release all air pressure from tank remove drain valve and clean then reinstall d After condensate has been drained close the drain cock IMPORTANT Observe air tank Date of Manufacture stamped on tank leg Replace air tank 2
7. ile sleepy or drowsy Do not use any tools or attachments without first determining maximum air pressure for that tool or attachment Never point any air nozzle or air sprayer toward another person or any part of the body This air compressor is equipped with an Automatic Reset Thermal Protector and can automatically restart after the thermal protector resets Always cut off power source when thermal protector becomes activated Wear safety glasses or goggles when operating this product Use only in well ventilated areas INSTALLATION Please read and follow the Installation Instruction carefully to avoid injury or damage to the compressor or your vehicle Each of our air source kits and parts have been carefully produced and packaged Before you begin installation please familiarize yourself with Installation Parts List Fig 1 of this manual Selecting a Mounting Location The selection of a proper mounting location for your air source kit will help ensure a long and trouble free service life Please pay close attention to the following guidelines 1 Select a FLAT AND SECURE location where the air source kit can be mounted To maximize air compressor performance locate compressor as CLOSE TO THE BATTERY as possible so that length of positive lead wire required is at a minimum Choose mounting location that is as cool as possible and AWAY FROM HEAT SOURCES The cooler the ambient temperature the less chance
8. lts Max Current Consumption 20 Amps Recommended Fuse 30 Amps Motor Type Perm Magnetic Horse Power 1 4 Max Working Pressure 200 PSI Max Duty Cycle 72 F amp 100 PSI 100 Max Duty Cycle 72 F amp 200 PSI 50 Max Restart Pressure 200 PSI Max Ambient Temperature 158 F Min Ambient Temperature 40 F Auto Reset Thermal Protection Yes PROBLEM Tank pressure drops when compressor shuts off Compressor runs continuously and air flow lower than normal Compressor runs continuously causing safety valve to open Excessive moisture in discharge CAUTION PROBLEM Compressor will not run Thermal Overload Protector cuts out repeatedly Excessive knocking or rattling POSSIBLE CAUSE S Loose drain cock Check valve leaking Loose connections Excessive air usage Loose connections Worn piston ring or inlet valve Clogged air filter element Faulty pressure switch Defective safety valve Excessive water in air tank High humidity CORRECTIVE ACTION Tighten drain cock Replace check valve or compressor Check all connections with soap and water solution and tighten Decrease air usage Check all connections with soap and water solution and tighten Replace compressor Replace air filter element Replace pressure switch Replace safety valve Drain tank tilt tank to drain and drain tank more frequently Move compressor to area with less humidity or use water sepa
9. rator NEVER DISASSEMBLE COMPRESSOR WHILE COMPRESSOR IS PRESSURIZED POSSIBLE CAUSE S No power or switch in off position Blown Fuse Motor overheats Faulty pressure switch if hooked up toa pressure switch Lack of proper ventilation ambient temperature too high Compressor valves failed Loose mounting bolts Worn bearing on eccentric or motor shaft Cylinder or piston ring is worn CORRECTIVE ACTION Make sure compressor switch is ON Disconnect compressor from power and replace fuse Refer to Specifications section for correct fuse amperage Let compressor cool off for about 30 minutes for thermal overload switch reset Replace pressure switch Move compressor to well ventilated area or area with lower ambient temperature Replace compressor Tighten bolts Replace compressor Replace compressor LIMITED WARRANTY VIAIR Corporation warrants this product when properly installed and under normal conditions of use to be free from defects in workmanship and materials for a period of one year from provided date of purchase To receive a replacement or for repairs return the complete unit to retailer from whom it was purchased along with proof of purchase Returns should be made within the time period and conditions of the retailer s policy for exchanges If you are unable to contact your dealer contact VIAIR directly for repairs or replacement at our option PLEASE NOTE THIS WARRANTY COVERS
Download Pdf Manuals
Related Search
Related Contents
Canon A3300 User Manual Eurofase 7277-24 Installation Guide Lenovo IdeaCentre B50-30 SMAN360 Manifold Digital com 3 Portas e 取扱説明書 Samsung NS190 Korisničko uputstvo TPV. - 2XMIL Soluciones GAS COOKER USAGE AND INSTALLATION MANUAL FSHG 60 Commune de Zénauva Copyright © All rights reserved.
Failed to retrieve file