1. EA P
2. 352978 Trusted platform module TPM socket motherboard not visible in this view 4 5 j 11 DIMM sockets on motherboard 24 13 Modular LOM mLOM connector on chassis floor CPUs and heatsinks up to two 14 Cisco modular RAID controller PCle riser dedicated riser with horizontal socket 6 Embedded SATA RAID header for RAID 5 key Cisco modular RAID controller card 7 SD card bays on motherboard two 16 Embedded SATA RAID mini SAS connectors on motherboard not visible in this view Internal USB 3 0 port on motherboard RTC battery on motherboard Power supplies up to two hot swappable when redundant as 1 1 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 51 SUPPLEMENTAL MAT
3. SES ILESESESESESI JC 4 653 Seas HDD 02 3 e E Ol lese HDD 05 HDD 07 B P e ES eee 0 3 opon measa me _ emertoni _ Unit identification button LED KVM connector used with KVM cable that provides two i 2 0 one VGA and one serial connector Notes 1 For more information about the KVM cable connection see KVM CABLE page 69 4 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel Figure 3 Chassis Rear View u 352977 PCle riser 1 slot 1 La Serial port RJ 45 connector PCle riser 2 slot 2 Two embedded on the motherboard Intel 1350 GbE Ethernet controller ports LAN1 LAN2
4. lo j jo B es n 7 9 G 9 3 m Ex a Eis ae D 1 Mok led PCle Riser 1 42 q i 352978 Drives SAS SATA drives are hot swappable 10 Trusted platform module TPM socket on motherboard not visible in this view Cooling fan mo
5. 3 CDS SES IL BES BEZ DAs Ra SBE EE 6 z s Iam cn JC B 25 x gt N HES HDD 01 gt 54 HDD 02 2 HDD 03 S C SarcacJ crees eges gsemexesesenegea cas e o HDD 04 EE t HDD 06 dsl HDD 07 El HDD 08 SATA RAID Controller Hub SATA SSATA m Each controller is listed separately in the BIOS You can select the boot order of the controllers in the BIOS use the Boot Options tab in the BIOS Setup Utility Note the following considerations B The default setting for this embedded controller hub is SATA RAID 0 1 and 10 support for up to eight SATA drives in two groups of four drives m You can upgrade this to support to SATA RAID 1 5 and 10 support for up to eight SATA drives in two groups of four drives by installing a RAID 5 key module on the motherboard m When you order the server with this embedded controller the controller is enabled in the BIOS m You cannot downgrade from using a HW RAID controller card to using the SW RAID embedded cont
6. CAB N5K6A NA Power Cord 200 240V 6A North America i m CAB AC L620 C13 AC Power Cord NEMA L6 20 C13 2M 6 5ft H EI sn CAB C13 CBN CABASY WIRE JUMPER CORD 27 C13 C14 10A 250V CAB C13 C14 2M CABASY WIRE JUMPER CORD PWR 2 Meter C13 C14 10A 250V CAB C13 C14 AC CORD PWR JMP IEC60320 C14 IEC6 0320 C13 3 0M r 34 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 15 Available Power Cords Product ID PID SFS 250V 10A AR CAB 9K10A AU SFS 250V 10A CN CAB 250V 10A CN CAB 9K10A EU SFS 250V 10A ID SFS 250V 10A IS Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model PID Description Power Cord SFS 250V 10A Argentina Power Cord 250VAC 10A 3112 Plug Australia Power Cord SFS 250V 10A China AC Power Cord 250V 10A PRC Power Cord 250VAC 10A CEE 7 7 Plug EU Power Cord SFS 250V 10A India Power Cord SFS 250V 10A Israel Images 0 L 2500 mm ZA Hd Cordset rating 10 A 250 500 V MAX Plug EL 219 IRAM 2073 Length 8 2 ft Connector EL 701 IEC60320 C13 E oy
7. L Plug EL 210 Zj n LII Cordset rating 10 A 250 V 500 V 77 S Length 2500mm Connector EL 701C EN 60320 C15 BS 1363A 13 AMP fuse Plug EL 218 CCEE GB2009 Cordset rating 10 250V Connector EL 701 o IEC60320 C13 3 Cordset rating 10 16 A 250 V Length 8 ft 2 in 2 5 m Plug EL 208 if Cordset rating 16 250V 2500 IEC60320 C13 35 CONFIGURING the SERVER Table 15 Available Power Cords Product ID PID PID Description Images CAB 9K10A IT Power Cord 250VAC 10A CEI 23 16 VII Plug Italy C15M EN60320 C15 CAB 9K10A SW Power Cord 250VAC 10A MP232 Plug Switzerland Cordset rating 10 A 250 V Z X Length 8 ft 2 in 2 5 m Connector IEC 60320 C15
8. 64 Motherboard Lithium Battery 64 Thermal Grease with syringe applicator for CPU to Heatsink Seal 64 Air Baffle Replacement Kit 65 CPU Heat Sink Cleaning Kit 65 RACKS 26 oa 54 oh Ghee ot ae hee enn e eE eae ee as 66 POUS gene eee ease 68 KVM CABLE te VER mer ee 69 Motherboard USB and SD Ports and RAID Card Backup Location 70 TECHNICAL SPECIFICATIONS Zl Dimensions and Weight 71 Power SDEGCINICALIONS eu xo uomo te ee SES 72 Environmental Specifications 73 Compliance Requirements 74 2 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model OVERVIEW OVERVIEW The Cisco UCS C220 M4 SFF rack server is the newest 2 socket 1U rack server from Cisco designed for both performance and expandability over a wide range of storage intensive infrastructure workloads from big data to collaboration The enterprise class UCS C220 M4 SFF server extends the capabilities of Cisco s Unified Computing System portfo
9. C220 M4 SFF Installed any internal 8 HDD Not allowed slot 1024 external C220 M4 SFF Installed Installed any 8 internal 8 HDD ES Not allowed on Motherboard 1024 external Notes 1 If you want to boot from a device other than the Cisco 12G SAS Modular RAID controller you can leave the card installed Just disable the OPROM for its slot and the system will boot even with the card installed 2 External PCle drive controller card is the Cisco 12G SAS 9300 8e and can be installed simultaneously with the Cisco 12G SAS Modular RAID controller Caveats B Amaximum of one Cisco 12G SAS 9300 8e can be installed and it can be installed only in slot 1 Note that a Storage Accelerator also can only be installed in slot 1 Therefore the system can support either one storage accelerator card or one Cisco 12G SAS 9300 8e but not both at the same time B For the Cisco 12G SAS Modular RAID controller you can choose an optional RAID configuration RAID 0 1 5 6 or 10 which is preconfigured at the factory The RAID level you choose must be an available RAID choice for the controller selected RAID levels 50 and 60 are supported although they are not available as configuration options B system supports up to eight SATA only drives if no embedded software RAID 5 key upgrade controller or Cisco 12G SAS Modular RAID controller is chosen NOTE For more important information regarding RAID support see RAID Details page
10. CAB 9K10A UK Power Cord 250VAC 10A BS1363 Plug 13 A fuse UK Cordset A SN L EL 210 EN _ BS 1363A 13 AMP fuse CAB 9K12A NA Power Cord 125VAC 13A NEMA 5 15 Plug North America Zi i CAB 250V 10A BR Power Cord 250V 10A Brazil EZ En AAT F Fai CAB JPN 3PIN Power Cord 3PIN Japan Image not available 36 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 10 ORDER RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM Select a Rail Kit Select a rail kit from Table 17 Table 16 Rail Kit Options Product ID PID PID Description UCSC RAILF M4 Friction Rail Kit for C220 M4 Servers UCSC RAILB M4 Ball Bearing Rail Kit for C220 M4 and C240 M4 Servers Select an Optional Reversible Cable Management Arm The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management Use Table 17 to order a cable management arm Table 17 Cable Management Arm Product ID PID PID Description UCSC CMA1 Cable Management Arm for C220 rack servers For more information about the rail kit and cable management arm see the Cisco UCS C220 M4 Installation and Service Guide at this URL http www cisco com c en US td docs unified_ computing ucs c hw C220M4 install C220M4 html e NOTE f you plan to rackmount your UCS C220 M4 server you must order a to
11. 37 STEP 11 ORDER A TRUSTED PLATFORM MODULE OPTIONAL 38 STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE OPTIONAL 39 STEP 13 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE 40 STEP 14 SELECT OPERATING SYSTEM MEDIA KIT 43 STEP 15 SELECT SERVICE and SUPPORT LEVEL 44 OPTIONAL STEP ORDER RACK S 49 OPTIONAL STEP ORDER PDU 50 SUPPLEMENTAL MATERIAL 91 51 CPUS anG DIMMS x s ennn kore eee ee bee Se Se ee Sd eee E EOS 52 PAVSICAUEAVOU 4 242644 64404 eu AU GS Gee eee os OER Rhee Oe OS eRe 52 Memory Population Rules 53 DIMM Population 54 Recommended Memory Configuration 55 Additional DIMM Populations 56 RAIDIDGCANS 24445464555 n 4444450 60 Soe RA RORIS ee eee 57 RAID Option ROM OPROM Settings 58 Embedded SATA RAID Two SATA Controllers 59 POMm DetANS waneer ee ese oes oe ea Ge ees 62 Upgrade and Servicing Related 63 Adding an Additional CPU with CPU heat sink
12. B Cisco memory from previous generation servers DDR3 is not compatible with this server For more information regarding memory see CPUs and DIMMs page 52 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 17 CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION NOTE If you do not select Cisco 126 SAS Modular RAID controller the embedded software RAID 5 key upgrade you will have two SATA only RAID controllers that support up to two sets of four SATA only drives RAID 0 1 The embedded RAID controller hub is split into two controllers SATA and sSATA secondary SATA These two controllers are seen as separate RAID controllers in the Cisco IMC interface and are configurable separately For more details see Embedded SATA RAID Two SATA Controllers page 59 NOTE When creating each RAID volume follow these guidelines m Use the same capacity for each drive in each RAID volume m Use either all SAS drives or all SATA drives in each RAID volume m Use either all HDDs or all SSDs in each RAID volume The embedded SATA only RAID controllers have two ports and each port can control 4 drives for 8 drives total However each set of 4 SATA drives for a port must be in separate RAID volumes You cannot mix drives across ports to create a RAID volume For more details see Embedded SATA RAID Two SATA Controllers page 59 NOTE The number of RAID groups virtual dr
13. SUPPLEMENTAL MATERIAL Air Baffle Replacement Kit Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level These baffles must always remain installed during server operation The Air Baffle Replacement Kit includes the air baffles needed for one UCS C220 M4 server CPU Heat Sink Cleaning Kit The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process Instructions for cleaning are found at the following link http www cisco com c en us td docs unified computing ucs c hw C220M4 install C220M4 html See the section titled Replacing CPUs and Heatsinks o NOTE When you purchase a spare CPU the CPU cleaning kit is included Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 65 SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack see Figure 14 is certified for Cisco UCS installation at customer sites and is suitable for the following equipment m Cisco UCS B Series servers and fabric interconnects m Cisco UCS C Series and select Nexus switches The rack is compatible with hardware designed for ElA standard 19 inch racks Rack specifications are listed in Table 36 Table 36 Cisco R42610 Rack Specifications Parameter Dimensions H x W x D Dimensions H x W x D with packaging Distance from front mounting rail to rear mounting rail
14. QON NCFCS C220M4SF NCFCS Yes CMBSPT SVC 8X5XNBDOS UCS C220 M4 SFF CON NCFE C220M4SF NCFE No CMB SPT SVC 8X5X4 UCS C220 M4 SFF CON NCFP C220M4SF NCFP NO CMB SPT SVC 24X7X4 UCS C220 M4 SFF CON NCFT C220M4SF NCFT No CMB SPT SVC 8X5XNBD UCS C220 M4 SFF Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention UCDR Service you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive In exchange for a Cisco replacement drive you provide a signed Certificate of Destruction CoD confirming that the drive has been removed from the system listed is no longer in service and has been destroyed Sophisticated data recovery techniques have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised which reduces the risk of any potential liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 28 o NOTE Cisco does not offer a certified drive destruction service as part of this service Table 28 Drive Retention Service Options Service Service Service Descrip
15. e One full height profile 3 4 length slot with x24 connector and x16 lane m Riser 2 e One half height profile half length slot with x24 connector and x16 lane m Dedicated Cisco 12G SAS Modular RAID controller slot e An internal slot is reserved for the 12G SAS Modular RAID controller card Drives are installed into front panel drive bays that provide hot pluggable access e Small Form Factor SFF drives Up to eight 2 5 inch SAS or SATA hot swappable hard disk drives HDDs or solid state drives SSDs m The server also contains one internal USB 2 0 port on the motherboard that you can use with a USB thumb drive for additional storage m UCS Storage Accelerators are also available These PCle flash storage devices provide independent high speed storage The server supports up to two internal 32 GB or two internal 64 GB Cisco Flexible Flash drives SD cards Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features continued Capability Feature Description Video The Baseboard Management Controller provides video m Matrox G200e video controller m Integrated 2D graphics core with hardware acceleration B Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 0 Hz 24 bit color depth for all resolutions less than 1600x1200 B 256 MB video memory Storage controller m Embedded
16. 12 x 8 GB 12 96 GB 12 x 8 GB 12 96 GB 192 GB 6 x 16 GB 6 96 GB 6 x 16 GB 6 96 GB 192 GB 8 x 16 GB 8 128 8x16 GB 128 GB 256 GB 4 x 32 GB 4 128GB 4x32 GB 4 128 GB 256 GB 12 x 16 GB 12 192GB 12x16 GB 12 192 GB 384 GB 6 x 32 GB 6 192GB 6x 32 GB 6 192 GB 384 GB 8 x 32 GB 8 256GB 8x32GB 8 256 GB 512 GB 12 x 32 GB 12 384GB 12 32 GB 12 384 GB 768 GB 56 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL RAID Details The available RAID configurations are shown in this section 1 1 and 2 CPU Configurations Select one of these The embedded software RAID 5 key upgrade option from Table 6 on page 19 or One Cisco 120 SAS Modular RAID controller from Table 7 on page 20 or One Cisco 9300 8 12G SAS RAID controller from Table 7 on page 20 One Cisco 12G SAS Modular RAID controller from Table 7 on page 20 and one Cisco 9300 8E 12G SAS RAID controller from Table 7 on page 20 Select an appropriate optional RAID configuration listed in Table 7 on page 20 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 57 SUPPLEMENTAL MATERIAL The server contains an Option ROM OPROM for the PCle slots The server has a finite amount of option ROM with which it can boot up devices Go into the BIOS and disable the OPROM on the PCle slots not used for booting so that resources are available for the slots that are used for booting An example OPROM B
17. Weight Weight with packaging Side panels included Equipment mounting capacity Static load capacity Dynamic load capacity Standard Rack 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 299 83 lb 136 kg 354 lb 161 kg Yes 42RU 2100 lb 954 kg Not applicable Expansion Rack 78 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm 29 2 in 741 mm 231 49 lb 105 kg 284 lb 129 kg No 42RU 2100 lb 954 kg Not applicable o NOTE The AC input connector is an IEC 320 C 14 15 A 250 VAC power inlet 66 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Figure 14 Cisco R42610 Rack Front view door Front view door open Front view door removed Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 67 SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units PDUs offer power distribution with branch circuit protection Cisco RP Series PDU models distribute power to up to 24 outlets The architecture organizes power distribution simplifies cable management and enables you to move add and change rack equipment without an electrician With a Cisco RP Series PDU in the rack you can replace up to two dozen input power cords with just one The fixed input cord connects to th
18. and RAID Card Backup Location The C220 M4 SFF motherboard has a general purpose USB socket and two SD sockets as shown in Figure 17 The mounting location for the RAID SuperCap data cache power backup module is also shown Figure 17 Motherboard USB and SD Ports and RAID Card SuperCap Location
19. DIMM capacities in the same slot this will result in less than optimal performance For optimal performance all DIMMs in the same slot should be identical 2 Only 2133 MHz DIMMs are currently available for the C220 M4 server Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 53 SUPPLEMENTAL MATERIAL DIMM Population Order Populate the DIMMs for a CPU according to Table 32 Table 32 DIMM Population Order per CPU DIMMs Populate Populate per CPU CPU 1 Slots CPU 2 Slots 1 A1 E1 2 A1 B1 E1 F1 3 A1 B1 C1 E1 F1 G1 4 A1 B1 C1 D1 E1 F1 G1 H1 61 A1 B1 C1 E1 F1 G1 A2 B2 C2 E2 F2 G2 8 A1 B1 C1 D1 E1 F1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2 12 A1 B1 C1 D1 E1 F1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2 A3 B3 C3 D3 E3 F3 G3 H3 Notes 1 Not recommended for performance reasons 54 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Recommended Memory Configuration This section explains the recommended DIMM population order rules for the C220 M4 server m All DIMMs must be DDR4 DIMMs B Do not mix DIMMs with different clock rates in a channel RDIMMs and LRDIMMs ECC and non ECC DIMMs m There are blue black and white DIMM slots Populate blue slots first B When DIMMs ranks are mixed in the same channel always populate the highest rank DIMM in the blue DIMM slot and lower rank
20. DIMM s in the black and white DIMM slots Many memory configurations are possible For best results follow Table 33 when populating 2133 MHz DIMMs for Intel Xeon E5 2600 v3 CPUs Table 33 Recommended Memory Configurations for Intel Xeon E5 2600 v3 CPUs with 2133 MHz DIMMs CPU 1 DIMMs CPU 2 DIMMs System Blue Slots Black Slots White Slots Blue Slots Black Slots White Slots 128GB 4x8GB 4x8 GB ERE 4x8 GB 4x8 GB NEM 2133 ww ves ore sora Mild E a o B cl cl gi leid Bl od od RN E Kd Kl Kd 2 Notes 1 Rows marked in yellow indicate best performance Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 55 SUPPLEMENTAL MATERIAL Additional DIMM Populations The list in Table 34 is not a complete list of all supported DIMM populations but highlights common configuration options Table 34 Supported DIMM Configurations CPU 1 DIMMs Paha CPU 2 DIMMs capacity for S 1 x 8 GB 1 8 GB 1 x 8 GB 1 8 GB 16 GB 2x 8 2 16 2 x 8 2 16 32 1 16 1 16 1 16 1 16 32 4 8 4 32 4 8 4 32 GB 64 GB 2 x 16 GB 2 32 GB 2 x 16 GB 2 32 GB 64 GB 1 x 32 GB 1 32 GB 1 x 32 GB 1 32 GB 64 GB 8 x 8 GB 8 64 GB 8 x 8 GB 8 64 GB 128 GB 4x 16 GB 4 64 GB 4x 16 GB 4 64 GB 128 GB 2 x 32 GB 2 64 GB 2 x 32 GB 2 64 GB 128 GB
21. Description SFP H10GB CU1M 10GBASE CU SFP Cable 1 M SFP H10GB CU3M 10GBASE CU SFP Cable 3 M SFP H10GB CU5M 10GBASE CU SFP Cable 5 M SFP H10GB ACU7M 10GBASE CU SFP Cable 7 M SFP H10GB ACU10M 10GBASE CU SFP Cable 10 M Approved Configurations 1 Choose Up to Two Twinax Cables for Each Network Card Ordered m You may choose one or two twinax cables for each compatible PCle network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Choose Optional SFP Modules Optical Cisco SFP modules are listed in Table 12 Table 12 Available SFP Modules Product ID PID PID Description SFP 10G SR 10GBASE SR SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring DS SFP FC8G SW 8 Gbit SFP Module 850 nm multimode SR 3 3V LC connector with Digital Optical Monitoring Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 29 CONFIGURING the SERVER Approved Configurations 1 Choose Up to Two SFP Modules for Each Network Card Ordered m You may choose one or two SFP optical modules cables for each compatible PCle network card ordered You would normally order two modules for connecting to the primary and redundant network switching equipment With the SFP optical modules you can use common fiber optic cables widely available See the
22. Environmental Specifications The power specifications for the C220 M4 server are listed in Table 40 Table 40 UCS C220 M4 SFF Environmental Specifications Parameter Minimum Temperature operating 41 to 95 5 to 35 C derate the maximum temperature by 1 C per every 1000 ft 305 m of altitude above sea level Temperature nonoperating 40 to 149 F 40 to 65 C Humidity RH operating 10 to 90 non condensing at 82 F 28 C Humidity RH nonoperating 5 to 93 at 82 F 28 C Altitude operating to 3 000 m 0 to 10 000 ft Altitude nonoperating to 12 192 m 0 to 40 000 ft Sound Power level Measure 5 4 A weighted per 1507779 LWAd Bels Operation at 73 F 23 C Sound Pressure level Measure 37 A weighted per 1507779 LpAm dBA Operation at 73 F 23 C Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 73 TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C Series servers are listed in Table 41 Table 41 UCS C Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A C
23. SLES for SAP Applications 1 2 CPU Unl 5yr Support Reqd Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 21 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID Red Hat Enterprise Linux RHEL 25 1G 1A RHEL 25 1G 3A RHEL 25 4G 1A RHEL 25 4G 3A RHEL 25 UG 1A RHEL 25 UG 3A RHEL HA 25 1A RHEL HA 25 3A RHEL RS 25 1A RHEL RS 25 3A RHEL SFS 25 1A RHEL SFS 25 3A BMC BMC 012 BMC SE 4C BMC SE 6C BMC SE 8C BMC SE 10C BMC AE 4C BMC AE 6C BMC AE 8C BMC AE 10C RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL 2 Socket 4 Guest 3Yr Svcs Required RHEL 2 Socket U Guest 1Yr Svcs Required RHEL 2 Socket U Guest 3Yr Svcs Required RHEL Option High Availability 2 Socket 1Yr Svcs Required RHEL Option High Availability 2 Socket 3Yr Svcs Required RHEL Option Resilient w Ha 2 Socket 1 Yr Svcs Required RHEL Option Resilient Storage w HA 2 Socket 3 Yr Svcs Reqd RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required BMC BPPM Per Server BMC BladeLogic Standard Edition 4 Cores Support Required BMC BladeLogic Standard Edition 6 Cores Support Required BMC BladeLogic Standard Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required BMC BladeLogic
24. Serial Port Details The pinout details of the rear RJ 45 serial port connector are shown in Figure 13 Figure 13 Serial Port Female RJ 45 Connector Pinout Pin Signal RTS Request to Send DTR Data Terminal Ready TxD Transmit Data GND Signal Ground GND Signal Ground RxD Receive Data DSR Data Set Ready CTS Clear to Send 62 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Upgrade and Servicing Related Parts This section lists the upgrade and servicing related parts you may need during the life of your server Some of these parts are configured with every server and some may be ordered when needed or may be ordered and kept on hand as spares for future use See Table 35 Drive Blanking Panels Table 35 Upgrade and Servicing related Parts for UCS C220 M4 LFF Server Spare Product ID PID Description UCSC HS C220M4 UCS CPU GREASE3 UCS CPU LPCVR UCSX HSCK UCSC PCI 2A 220M4 UCSC PCI 2C 220M4 UCSC PCIF 01H UCSC PCIF 01F N20 BBLKD UCSC MLOM BLK UCSC RAILF M4 UCSC CMAF M4 UCSC RAILB M4 UCSC FAN C220M4 UCSC BAFF C220M4 N20 BKVM UCSC PSU BLKP1U UCS 220CBLSR8 UCS 220CBLMR8 Notes Heat sink for UCS C220 M4 rack servers M4 Server CPU thermal grease syringe needed for heatsink seal CPU load plate dust cover for unpopulated CPU sockets UCS Processor Heat Sink Cleaning Kit For Replacement of CP
25. either all SAS drives or all SATA drives in each RAID volume m Use either all HDDs or all SSDs in each RAID volume m The embedded SATA only RAID controllers have two ports and each port can control 4 drives for 8 drives total However each set of 4 SATA drives for a port must be in separate RAID volumes You cannot mix drives across ports to create a RAID volume For more details see Embedded SATA RAID Two SATA Controllers page 59 24 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Approved Configurations 1 Embedded RAID or Cisco 12G SAS Modular RAID Controller B If you have not selected an embedded software RAID 5 key upgrade option UCSC SWRAID5 or a Cisco 12G SAS Modular RAID controller for internal drives you will have an SATA only RAID controller that supports up to eight SATA only drives RAID 0 1 Select up to eight SATA only drives from Table 9 on page 23 B If you selected an embedded RAID 5 key upgrade option supports RAID 0 1 5 and 10 select up to eight SATA drives listed in Table 9 B If you selected a Cisco 126 SAS Modular RAID controller for internal HDDs SSDs you have the following options Cisco 12G SAS Modular RAID controller with no FBWC option supports JBOD RAID 0 1 10 Cisco 12G SAS Modular RAID controller with FBWC option supports JBOD RAID 0 1 5 10 50 and 60 For either option select up to eight SAS d
26. server as shown in Table 2 Table 2 PID of the C220 M4 High Density SFF Rack Base Server Product ID PID Description UCSC C220 M4S UCS C220 M4 SFF no CPU memory HDD SSD power supply SD cards PCle cards or rail kit The Cisco UCS C220 M4 SFF server B Does not include power supply CPU memory hard disk drives HDDs solid state drives SSDs SD cards rail kit or plug in PCle cards NOTE Use the steps on the following pages to configure the server with ee the components that you want to include 10 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model STEP 2 SELECT CPU s The standard CPU features are m Intel Xeon E5 2600 v3 series processor family CPUs m Intel C610 series chipset m Cache size of up to 45 MB Select CPUs The available CPUs are listed in Table 3 Table 3 Available Intel CPUs E5 2600 v3 Series Processor Family CPUs CONFIGURING the SERVER Product ID PID UCS CPU E52699D UCS CPU E52698D UCS CPU E52697D UCS CPU E52695D UCS CPU E52690D UCS CPU E52683D UCS CPU E52680D UCS CPU E52670D UCS CPU E52667D UCS CPU E52660D UCS CPU E52650D UCS CPU E52650LD UCS CPU E52643D UCS CPU E52640D UCS CPU E52637D UCS CPU E52630D UCS CPU E52630LD UCS CPU E52623D UCS CPU E52620D UCS CPU E52609D2 Notes Intel Number E5 2699 v3 E5 2698 v3 E5 2697 v3 E5 2695 v3 E5 2690 v3 E5 2683 v3 E5 2680 v3 5 2670 v3 E5 2667 v3 E5 2660 v3 E5 2
27. 11 11 CISCO Spec Sheet Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model Cisco SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV A 5 OCTOBER 15 2014 WWW CISCO COM OVERVIEW ER XX Re ee DETAILED VIEWS 31 9954 4 1 4 3 9 135 9 9 379 Chassis Front VIEW 4 Chassis Rear VIEW axe e a WS E s 5 BASE SERVER STANDARD CAPABILITIES and FEATURES 6 CONFIGURING the SERVER 9 STEP 1 VERIFY SERVER SKU 2 lt 34 444 444444 e060 10 STEP Z SELECT CPUG _ 11 STEP SELECT MEMORY 2444425545422 UV Re om ae So ee TEE 13 STEP 4SELECT RAID CONFIGURATION 18 STEP 5 SELECT HARD DISK DRIVES HDDs or SOLID STATE DRIVES SSDs 23 STEP 6SELECT PCle OPTION CARD s 26 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES 29 STEP 5 33 STEP 9 SELECT AC POWER CORD s 34 STEP 10 ORDER RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM
28. 220 SFF Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment The more benefits you realize from the Cisco Unified Computing System Cisco UCS the more important the technology becomes to your business These services allow you to B Optimize the uptime performance and efficiency of your UCS B Protect your vital business applications by rapidly identifying and addressing issues m Strengthen in house expertise through knowledge transfer and mentoring Improve operational efficiency by allowing 5 experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operations 46 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER You can choose a service listed in Table 27 Table 27 UCS Computing Combined Support Service Service On T Product ID PID Level GSP Site Description QON NCF2 C220M4sF 2 No CMB SPT SVC 24X7X2 UCS C220 M4 SFF QON NCF2P C220M4SF X NCF2P Yes CMB SPT SVC 24X7X20S UCS C220 SFF CON NCF4P C220M4SF Yes CMB SPT SVC 24X7X4OS UCS C220 SFF QON NCFA4S C220M4SF 45 Yes CMB SPT SVC 8X5X4OS UCS C220 M4 SFF
29. 57 and RAID Option ROM OPROM Settings page 58 22 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 5 SELECT HARD DISK DRIVES HDDs or SOLID STATE DRIVES SSDs The standard disk drive features are B 2 5 inch small form factor B Hot pluggable B Drives come mounted in sleds Select Drives The available drives are listed in Table 9 Table 9 Available Hot Pluggable Sled Mounted HDDs and SSDs Product ID PID PID Description HDDs 15K RPM UCS HD600G15KS2 E 600 GB 6 Gbps SAS 15K RPM SFF HDD UCS HD450G15KS2 E 450 GB 6 Gbps SAS 15K RPM SFF HDD UCS HDD300GI2F105 300 GB 6 Gbps SAS 15K RPM SFF HDD HDDs 10K RPM Drive Type SAS SAS SAS Capacity 600 GB 450 GB 300 GB UCS HD12T10KS2 E 1 2 TB 6 Gbps SAS 10K RPM SFF HDD UCS HDD900GI2F106 900 GB 6 Gbps SAS 10K RPM SFF HDD SAS SAS SAS SAS 1 2 TB 900 GB 600 GB 300 GB A03 D300GA2 300 GB 6 Gbps SAS 10K RPM SFF HDD A03 D600GA2 600 GB 6 Gbps SAS 10K RPM SFF HDD HDDs 7 2K RPM UCS HD1T7KS2 E 1 TB 6 Gbps SAS 7 2K RPM SFF HDD SAS SATA 1 TB 1 TB A03 D1TBSATA 1 TB 6 Gbps SATA 7 2K RPM SFF HDD Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 23 CONFIGURING the SERVER Table 9 Available Hot Pluggable Sled Mounted HDDs and SSDs continued Product ID PID Enterprise Performance SSDs high endurance supports up to 10 FDWP full drive wri
30. 650 v3 E5 2650L v3 E5 2643 v3 E5 2640 v3 5 2637 E5 2630 v3 E5 2630L v3 E5 2623 v3 E5 2620 v3 E5 2609 v3 145 135 145 120 135 120 120 120 135 105 105 65 135 90 135 85 59 105 85 85 Cache Size MB 45 40 35 35 30 35 30 30 20 25 25 30 20 20 15 20 20 10 15 15 Cores O O A CO CO LK co OPI 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 8 0 GT s 9 6 GT s 8 0 GT s 8 0 GT s 8 0 GT s 8 0 GT s 6 4 GT s Highest DDR4 DIMM Clock Support MHz 2133 2133 2133 2133 2133 2133 2133 2133 2133 2133 2133 1866 2133 1866 2133 1866 1866 1866 1866 1600 1 If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock 2 The E5 2609 v3 CPU does not support Intel Hyper Threading or Intel Turbo Boost technologies Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 11 12 CONFIGURING the SERVER Approved Configurations 1 1 CPU configurations m Select any one CPU listed in Table 3 on page 11 2 2 CPU Configurations m Select two identical CPUs from any one of the rows of Table 3 on page 11 Caveats You can select either one processor or two identical processors For optimal performance select DIMMs with the highest
31. A1 B1 C1 D1 A2 B2 C2 D2 A3 B3 C3 D3 Notes 1 Not recommended for performance reasons m Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 14 3 2 CPU configuration without memory mirroring m Select from 1 to 12 DIMMs per CPU Refer to Memory Population Rules page 53 for more detailed information 4 2 CPU configuration with memory mirroring m Select 2 4 6 8 or 12 identical DIMMs per CPU The DIMMs will be placed by the factory as shown in the following table Number CPU 1 DIMM Placement in Channels CPU 2 DIMM Placement in Channels of for identical dual rank DIMMs for 3DPC or for identical dual rank DIMMs for 3DPC or sed identical quad rank DIMMs for 2DPC identical quad rank DIMMs for 2DPC er P Blue Slots Black Slots White Slots Blue Slots Black Slots White Slots A1 B1 E1 F1 4 A1 B1 E1 F1 C1 D1 G1 H1 61 A1 B1 C1 A2 B2 C2 E1 F1 G1 E2 F2 C2 8 A1 B1 A2 B2 E1 F1 E2 F2 C1 D1 C2 D2 G1 H1 G2 H2 12 A1 B1 A2 B2 A3 B3 E1 F1 E2 F2 E3 F3 C1 D1 C2 D2 C3 D3 G1 H1 G2 H2 G3 H3 Notes 1 Not recommended for performance reasons Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 15 CONFIGURING the SERVER m Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 14 Caveats NOTE System performa
32. ACK FASTEN 001 RACK FASTEN 002 RACK JOIN 001 Notes PID Description Cisco R42610 expansion rack no side panels Cisco R42610 standard rack w side panels Filler panels qty 12 1U plastic toolless Cable mgt D rings qty 10 metal Cable mgt straps qty 10 Velcro Mounting screws qty 100 M6 Cage nuts qty 50 M6 Rack joining kit 1 Use these same base PIDs to order spare racks available only as next day replacements For more information about the R42610 rack see RACKS page 66 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 49 OPTIONAL STEP ORDER PDU OPTIONAL STEP ORDER PDU An optional power distribution unit PDU is available from Cisco for the C Series rack servers including theC220 M4 server This PDU is available in a zero rack unit RU style see Table 29 Table 30 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU For more information about the PDU see PDUs page 68 50 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C220 M4 chassis with the top cover removed is shown in Figure 6 Figure 6 C220 M4 SFF With Top Cover Off
33. Advanced Edition 4 Cores Support Required BMC BladeLogic Advanced Edition 6 Cores Support Required BMC BladeLogic Advanced Edition 8 Cores Support Required BMC BladeLogic Standard Edition 10 Cores Support Required Nexus 1000V for Hyper V and vSphere N1K VSG UCS BUN N1K VLEM UCS 1 VSG VLEM UCS 1 UCS Director CUIC PHY SERV BM U CUIC PHY SERV U CUIC TERM Over half off N1K and VSG w purchase of UCS B C Series Nexus 1000V License Paper Delivery 1 CPU for bundles VSG License Paper Delivery 1 CPU for bundles Cisco Cloupia Resource Lic One Phy Server node bare metal Cisco Cloupia Resource Lic One physical Server node Acceptance of Cisco Cloupia License Terms Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 41 CONFIGURING the SERVER Table 21 OSs and Value Added Software for 2 CPU servers continued PID Description VMware 5 VMW VS5 STD 1A VMW VS5 STD 2A VMW VS5 STD 3A VMW VS5 STD 4A VMW VS5 STD 5A VMW VS5 ENT 1A VMW VS5 ENT 2A VMW VS5 ENT 3A VMW VS5 ENT 4A VMW VS5 ENT 5A VMW VS5 ENTP 1A VMW VS5 ENTP 2A VMW VS5 ENTP 3A VMW VS5 ENTP 4A VMW VS5 ENTP 5A VMW VC5 STD 1A VMW VC5 STD 2A VMW VC5 STD 3A VMW VC5 STD 4A VMW VC5 STD 5A UCS VMW TERMS 42 Product ID PID VMware vSphere 5 Standard for 1 Processor 1 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 2 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 3 Year Support Rqd VMware vSphe
34. ERIAL CPUs and DIMMs Physical Layout Each CPU has four DIMM channels B CPU1 has channels A B C and D B CPU2 has channels F G and Each DIMM channel has three slots slot 1 slot 2 and slot 3 The blue colored DIMM slots are for slot 1 the black colored slots for slot 2 and the white slots for slot 3 As an example DIMM slots A1 B1 C1 and D1 belong to slot 1 while A2 B2 C2 and D2 belong to slot 2 Figure 7 shows how slots and channels are physically laid out on the motherboard The DIMM slots on the right half of the motherboard channels A B C and D are associated with CPU 1 while the DIMM slots on the left half of the motherboard channels E F G and H are associated with CPU 2 The slot 1 blue DIMM slots are always located farther away from a CPU than the corresponding slot 2 black and slot 3 white slots Slot 1 slots blue are populated before slot 2 slots black and slot 3 white slots Figure 7 Physical Layout of CPU DIMM Channels and Slots e e noen gn Cen C e en 084 DUDUO TE ITI ODO oon lt lt Front of Server TOP view 52 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server you should consider the following items B Each channel has three DIMM slots for example ch
35. Figure 5 on page 32 for typical SFP and twinax connections to the network cards Caveats Check the table on the following page for compatibility between the PCle network cards and SFPs or twinax cables NOTE The table shows all PCle network cards for all C series servers Not all of the cards shown in the table are supported in this server The intent of the table is to show compatibility between cards and twinax cables or SFPs 30 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 13 PCle Card Compatibility Twinax Cisco SFP Modules Cables SFP 10G SR DS SFP FC8G SW Converged Network Adapters CNAs UCSC PCIE BSFP Broadcom 57712 Dual Port 10Gb SFP w TOE iSCSI zs UCSC PCIE CSC 02 lt lt No Cisco VIC 1225 Dual Port 10Gb SFP CNA UCSC PCIE C10T 02 No No No Cisco VIC 1225T Dual Port 10GBaseT CNA UCSC PCIE C40Q 02 Cisco VIC 1285 Dual Port 40Gb QSFP CNA UCSC PCIE C40Q 03 Cisco VIC 1385 Dual Port 40Gb QSFP CNA w RDMA UCSC PCIE ESFP Emulex 11102 dual port 10 GbE FCoE CNA Gen 3 UCSC PCIE QSFP QLogic QLE8242 CU dual port 10 GbE FCoE CNA Use Qlogic SFP UCSC PCIE B3SFP Broadcom 57810 10Gb A FEX SFP UCSC PCIE Q8362 Qlogic QLE8362 dual port 10 GbE FCoE CNA Use Qlogic SFP UCSC PCIE E14102 Emulex 14102 dual port 10 GbE FCoE CNA Network Interface Cards NICs N2XX ABPCIO1 M3 B
36. IOS screen is shown in Figure 8 Figure 8 Example BIOS Screen for OPROM Aptio Setup Utility Copyright D 2012 American Megatrends Inc Advanced A Enable or Disable all PCIe 51015 oprom execution LOM Port OptionRoH Enabled LOM Port 4 ptionR M Enabled All PCIe Slots Opt ionROM Enabled Tr ne rt 4 i 4 i e 1 ro PCIe 510110 1 Opt 1onK0M LEnabled SlotID 2 ptionR M Et ak led 11 Enter amp T r OA De rr SlotID M ptionRUM Enan led version 2 15 1226 Copyright C 2012 American Megatrends Inc 58 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL Embedded SATA RAID Two SATA Controllers The embedded SATA RAID controller hub is split into two controllers SATA and sSATA secondary SATA These two controllers are seen as separate RAID controllers in the Cisco IMC interface and are configurable separately m The first SATA controller controls drives 1 4 the secondary sSATA controller controls drives 5 8 m When configuring RAID groups you cannot create a group that spans more than four drives m The first SATA controller can control a RAID group of up to four drives consisting only of drives 1 4 B The secondary sSATA controller can control a RAID group of up to four drives consisting only of drives 5 8 See Figure 9 Figure 9 Embedded RAID Controller RAID Groups
37. ISPR22 Class A EN55022 Class A ICESOO3 Class A VCCI Class A EN61000 3 2 EN61000 3 3 KN22 Class A CNS13438 Class A EMC Immunity EN55024 CISPR24 EN300386 KN24 Americas Headquarters Asia Pacific Headquarters Europe Headquarters Casco Systems Inc Cisco Systems USA Pte Lid Cisco Systems International BV Amsterdam san Jose CA singapore The Netherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website al www cisco com go olfices Cisco and the Cisco Logo are trademarks of Cisco Systems Inc and or its affiliates in the US and other countries A listing of Cisco s trademarks can be found af wwwciscocom go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1005R 74 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model
38. JBOD attach m Supports external JBOD using X4 and X8 wide SAS ports NOTE For Cisco 12G SAS 9300 8e HBA external drive enclosure Support see the enclosure section of the compatibility list at the following link T http tinyurl com pp83xyk Customers should contact their storage vendor for technical support related to external JBOD enclosures SuperCap Option UCSC MRAID SC Spare SuperCap for Cisco 12G SAS Modular RAID including all cables This is a Spare SuperCap It is the exact same SuperCap that ships with the FBWC options listed earlier in this table and can be used as a replacement or upgrade part 20 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 7 RAID Controller Options continued Product ID PID PID Description RAID Configuration Options not available for embedded RAID 5 key upgrade R2XX SRAIDO Enable Single Disk Raid O Setting R2XX RAIDO Factory preconfigured RAID striping option Enable RAID 0 Setting Requires a minimum of one hard drive R2XX RAID1 Factory preconfigured RAID mirroring option Enable RAID 1 Setting Requires exactly two drives with the same size speed capacity R2XX RAID5 Factory preconfigured RAID option Enable RAID 5 Setting Requires a minimum of three drives of the same size speed capacity R2XX RAID6 Factory preconfigured RAID option Enable RAID 6 Setting Requires a minimum of four drives of the same s
39. M MSWS 12R2 ST2S RM MSWS 12R2 DC2S RM PID Description RHEL 6 Recovery Media Only Multilingual SLES 11 media only multilingual Windows Svr 2008 R2 ST 1 4CPU 5CAL Media Windows Svr 2008 R2 EN 1 8CPU 25CAL Media Windows Svr 2008 R2 DC 1 8CPU 25CAL Media Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media Windows Server 2012 Datacenter 2 CPU Unlimited VM Rec Media Windows Server 2012 R2 Standard 2 CPU 2 VMs Recovery Media Windows Server 2012 R2 Datacen 2 CPU Unlimited VM Rec Media Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 43 CONFIGURING the SERVER STEP 15 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available as described in this section Unified Computing Warranty No Contract If you have noncritical implementations and choose to have no service contract the following coverage is supplied m Three year parts coverage Next business day NBD onsite parts replacement eight hours a day five days a week 90 day software warranty on media Ongoing downloads of BIOS drivers and firmware updates UCSM updates for systems with Unified Computing System Manager These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications release notes and industry standards SMART net for UCS For support of the entire Unified Computing System Cisco offers the Cisco SMART net fo
40. Model SUPPLEMENTAL MATERIAL 2 Press Ctrl M to start the RAID group creation process for the primary SATA controller for drives 1 4 as shown in Figure 9 on page 59 Or do nothing and wait for the next screen which allows you to create a RAID group for the secondary SATA 55 controller see Figure 12 Figure 12 Screen to Configure Secondary SATA sSATA RAID Group Device present at port 3 5 T91000640N5 01 Virtual drive s Configured Mode stripe Size No Of Stripes Drivesize RAID 10 4 a4 1905440HB Press Ctrl M or Enter to run LSI Software RAID Setup Utility LSI MegaRAID Software RAID BIOS Version 14 052615448 LSI ssATA RAID Found at PCI Bus No 00 Dev Ho 11 Device present at port INTEL SSDSC4ZHHZ0005 Device present at port 1 INTEL SSDSC2BAZ00G 3 Device present at port 2 INTEL SSDSC2BB120G4 Device present at port 3 Micron P4GOe HTFDDAK1O0HAR Virtual drivets Configured Mode stripe Size No Of Stripes Drivesize RAID O 64KB 189781HB RAID G4KB 18978 1MB RAID G4KB 113487MB RAID G4KB 94413HB Press Ctrl M or Enter to run LSI Software RAID Setup Utility 95335 Status 1902 70ME 1902 70MB 113961 EE EDU Status 3 Press Ctrl M to start the RAID group creation process for the secondary SATA sSATA controller for drives 5 8 as shown in Figure 9 on page 59 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 61 SUPPLEMENTAL MATERIAL
41. Modular LAN on motherboard mLOM VGA video port DB 15 card slot m Grounding lug hole for DC power supplies 10 Rear unit identification button LED USB 3 0 ports two Power supplies up to two redundant as 1 1 Notes 1 For details of the serial port pinout see Embedded SATA RAID Two SATA Controllers page 59 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 5 BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server Details about how to configure the server for a particular feature or capability for example number of processors disk drives or amount of memory are provided in CONFIGURING the SERVER page 9 Table 1 Capabilities and Features Capability Feature Description Chassis CPU Chipset Memory Multi bit Error Protection Embedded NIC Expansion slots Internal storage devices Cisco Flexible Flash drives One rack unit 1RU chassis One or two Intel Xeon E5 2600 v3 series processor family CPUs Intel C610 series chipset 24 slots for registered DIMMs RDIMMs or load reduced DIMMs LRDIMMs This server supports multi bit error protection Two embedded on the motherboard Intel 1350 GbE ports supporting the following m Pre Execution Boot PXE boot m iSCSI boot m Checksum and segmentation offload m NIC teaming m Riser 1
42. Small Form Factor Disk Drive Model 71 TECHNICAL SPECIFICATIONS Power Specifications The general power specifications for the C220 M4 SFF server 770 W AC power supply are listed in Table 39 Table 39 UCS C220 M4 SFF 770 W Power Supply Specifications Description Specification AC input voltage 100 240 VAC nominal input voltage range 90 64 VAC min max input voltage range AC input frequency 47 to 63 Hz single phase Maximum AC input current 9 5 Amps maximum at 100 VAC 4 5 Amps maximum at 208 VAC Maximum AC inrush current 15 Amps peak at 35 degree C 208V charging current for EMI X capacitors is not considered to be inrush current Maximum output power for each For 90 264 VAC input range the maximum rated output power power supply is 770 watts per power supply Power supply output voltage 12 VDC 5 Power supply efficiency CSCI Platinum 230 VAC at 50 Hz Greater than m 90 at 20 load m 94 at 50 load m 91 at 100 load In addition 208 VAC at 60 Hz efficiency shall be greater than m 89 at 20 load m 93 at 50 load m 90 at 100 load o NOTE AC input connector is an IEC 320 C 14 15A 250VAC power inlet For configuration specific power specifications use the Cisco UCS Power Calculator at this URL https mainstayadvisor com Go Cisco Cisco UCS Power Calculator aspx 72 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model TECHNICAL SPECIFICATIONS
43. Software RAID 6 Gbps e Embedded SATA only RAID controller supporting up to eight SATA only drives RAID 0 1 or e Embedded Software RAID 5 key upgrade supporting up to eight SATA only drives RAID 0 1 5 10 m Cisco 12G SAS Modular RAID controller card supporting up to eight drives which plugs into a dedicated RAID controller slot This card can be purchased alone or along with an onboard Flash Backed Write Cache FBWC upgrade option as shown in the table below RAID Card Version Supported RAID Levels Onboard FBWC UCSC MRAID12G JBOD 0 1 10 None UCSC MRAID12G 1GB JBOD 0 1 5 6 10 50 60 1 GB UCSC MRAID12G 2GB JBOD 0 1 5 6 10 50 60 2 GB UCSC MRAID12G A4GB JBOD 0 1 5 6 10 50 60 4 GB Notes 1 Base RAID controller card 2 FBWC option m Cisco 9300 8E 12G SAS PCle external drive controller e Cisco 12G SAS 9300 8e HBA with 8 external ports SAS 3 0 compliant Provides eight external SAS ports There is no cache or cache power backup WoL The 1 Gb Base T Ethernet LAN ports support the wake on LAN WoL Standard Front Panel A front panel controller provides status indications and control buttons Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 7 BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features continued Capability Feature Description Modular LAN on Motherboard mLOM slot Interfaces Power subsy
44. U C220 M4 PCle Riser 1 amp 2 Assy C220 M4 PCle Riser 3 HBA PCle Low Profile blanking panel for UCS C Series Server PCle Full Height blanking panel for UCS C Series Server HDD blanking panel MLOM blanking panel Friction Rail Kit for C220 M4 rack servers Reversible CMA for C220 M4 friction amp ball bearing rail kits Ball Bearing Rail Kit for C220 M4 and C220 M4 rack servers C220 M4 Fan Module one C220 M4 Air Baffle Plastic Kit KVM cable for Server console port Power Supply Blanking Panel for C220 M4 servers C220 M4 set of 2 SATA SW RAID cables for 8HDD bckpln chassis C220 M4 set of 2 RAID cntrlr cables for SHDD bckpln chassis 1 A drive blanking panel must be installed if you remove a disk drive from a UCS server These panels are required to maintain system temperatures at safe operating levels and to keep dust away from system components Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 63 SUPPLEMENTAL MATERIAL Adding an Additional CPU with CPU heat sink All Cisco UCS two CPU socket capable servers can be upgraded from having one to having two CPUs configured You will need to order and install a heat sink when adding any additional CPU to a server Instructions for installing the new CPU and heat sink can be found at the following link http www cisco com c en us td docs unified_ computing ucs c hw C220M4 install C220M4 html See the section titled Replacing CPUs and Hea
45. aRAID controller Hypervisors such as Hyper V Xen or KVM also supported for use with the embedded MegaRAID controller Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 19 CONFIGURING the SERVER Table 7 RAID Controller Options Product ID PID PID Description RAID Controller for Internal Drives Note that if the following Cisco 12G SAS modular RAID controller is selected it is factory installed in a dedicated internal Cisco Modular RAID controller PCle slot UCSC MRAID12G Cisco 12G SAS Modular Raid Controller Supports up to 8 internal SAS drives m Supports JBOD RAID O 1 10 Flash Backed Write Cache FBWC Upgrade Options for Cisco 12G SAS Modular RAID controller UCSC MRAID12G 1GB 1 GB FBWC which includes a 1 GB MB memory plus a SuperCap for write cache backup Supports JBOD RAID 0 1 5 6 10 50 and 60 UCSC MRAID12G 2GB 2 GB FBWC which includes a 2 GB MB memory plus a SuperCap for write cache backup Supports JBOD RAID 0 1 5 6 10 50 and 60 UCSC MRAID12G 4GB 4 GB FBWC which includes a 4 GB MB memory plus a SuperCap for write cache backup Supports JBOD RAID 0 1 5 6 10 50 and 60 SAS HBA for External J BOD Attach Note that the Cisco 12G SAS 9300 8e if selected is installed by default in slot 1 Two SFF8644 mini SAS x4 connectors on this card are accessible at the rear of the chassis UCSC SAS9300 8E Cisco 12G SAS 9300 8e SAS HBA for external
46. age 20 NOTE The Cisco 12G SAS modular RAID controller can be ordered with or without an optional FBWC The FBWC option backs up the RAID controller write cache The FBWC is available in 1 GB 2 GB or 4 GB sizes See Table 7 on page 20 for details NOTE For all valid combinations of embedded RAID and internal external RAID controller combinations see RAID Details page 57 Table 6 shows the product ID for the C220 M4 server entry level RAID solution This RAID option is accomplished with embedded software that supports a limited number of drives operating systems and virtualized environments For a more comprehensive enterprise RAID solution choose the Cisco 12G SAS modular RAID controller listed in Table 7 on page 20 Table 6 Entry Level RAID Solution Product ID PID PID Description Embedded Software RAID 5 Key Upgrade UCSC SWRAID5 Embedded Software RAID 5 key upgrade consisting of a storage controller unit SCU module that plugs into a 2 pin header on the motherboard supporting up to eight internal SATA only drives See Embedded SATA RAID Two SATA Controllers page 59 This module upgrades the embedded software RAID controller options to add RAID 5 This option supports RAID 0 1 5 10 and operates at 6 Gbps Operating systems supported are Windows and Linux only no VMware support NOTE VMware ESX ESXi or any other virtualized environments are not supported for use with the embedded Meg
47. annel A slots A1 A2 and A3 channel can operate with one two or three DIMMs installed If a channel has only one DIMM populate slot 1 first the blue slot B When both CPUs are installed populate the DIMM slots of each CPU identically Fill blue slots in the channels first A1 E1 B1 F1 C1 G1 D1 H1 Fill black slots in the channels second A2 E2 B2 F2 C2 G2 D2 H2 Fill white slots in the channels third A3 E3 B3 F3 C3 G3 D3 H3 B Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized B Observe the DIMM mixing rules shown in Table 31 Table 31 DIMM Rules for C220 M4 Servers DIMM Parameter DIMMs in the Same Channel DIMM in the Same Slot DIMM Capacity RDIMM 8 or 16 GB DIMMs in the same channel for For best performance DIMMs in the example A1 A2 and can have same slot for example A1 B1 C1 different capacities D1 should have the same capacity LRDIMM 32 GB Do not mix LRDIMMs with RDIMMs Do not mix LRDIMMs RDIMM s DIMM Speed 2133 MHz DIMMs will run at the lowest speed DIMMs will run at the lowest speed of of the DIMMs CPUs installed the DIMMs CPUs installed DIMM Type RDIMMs or LRDIMMs Do not mix DIMM types in a channel Do not mix DIMM types in a slot 1 DPC 2 DPC or 3 DPC DIMMs per Channel DPC See Table 5 on page 16 for valid LRDIMM and RDIMM 1 DPC 2 DPC and 3 DPC memory configurations Notes 1 Although you can have different
48. clock speed for a given processor see Table 3 on page 11 If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal performance will result Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are m DIMMs Clock speed 2133 MHz Ranks per DIMM 1 2 or 4 Operational voltage 1 2 V Registered ECC DDR4 DIMMs RDIMMs or load reduced DIMMs LRDIMMs B Memory is organized with four memory channels per CPU with up to three DIMMs per channel as shown in Figure 4 Figure 4 C220 M4 SFF Memory Organization 5 5 p 5 amp 5 LA uw ui v wv E3 E2 El Chan D Chan H 24 DIMMS 768 GB maximum memory 4 memory channels per CPU up t 3 DIMMs per channel Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 13 CONFIGURING the SERVER Select DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option The available memory DIMMs and mirroring option are listed in Table 4 Q NOTE When memory mirroring is enabled the memory subsystem simultaneously writes identical data to two channels If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error the system automatically retrieves the data from the other channel A transient o
49. dules six PCle riser 2 half height PCle slot 2 SuperCap Power Module RAID backup 12 PCle riser 1 full height PCle slot 1 mounting bracket DIMM sockets on motherboard 24 Modular LOM mLOM connector on chassis floor CPUs and heatsinks up to two 14 Cisco modular RAID controller PCle riser dedicated riser with horizontal socket 6 Embedded SATA RAID header for RAID 5 key Cisco modular RAID controller card SD card bays on motherboard two Embedded SATA RAID mini SAS connectors on motherboard not visible in this view Internal USB 3 0 port motherboard RTC battery on motherboard Power supplies up to two hot swappable when redundant as 1 1 70 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 38 UCS C220 M4 Dimensions and Weight Parameter Height Width Depth Front Clearance Side Clearance Rear Clearance Weight Maximum 8 HDDs 2 CPUs 16 DIMMs 2 770 W power supplies Minimum 1 HDD 1 CPU 1 DIMM 1 770 W power supply Bare HDD CPU DIMM 1 770 W power supply Value 1 7 in 4 32 cm 16 89 in 43 0 cm including handles 18 98 in 48 2 cm 29 8 in 75 6 cm including handles 30 98 in 78 7 cm 3 in 76 mm 1 in 25 mm 6 in 152 mm 37 9 lbs 17 2 kg 30 5 lbs 13 8 kg 29 2 lbs 13 2 kg Cisco UCS C220 M4 High Density Rack Server
50. e power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit ORU PDU See Figure 15 Figure 15 Zero Rack Unit PDU PID RP208 30 2P U 2 C13 plugs En Breakers En C19 plugs Ground connection Cisco RP Series PDU models provide two 20 ampere A circuit breakers for groups of receptacles The effects of a tripped circuit are limited to a receptacle group Simply press a button to reset that circuit 68 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model SUPPLEMENTAL MATERIAL KVM CABLE The KVM cable provides a connection into the server providing a DB9 serial connector a VGA connector for a monitor and dual USB ports for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM cable ordering information is listed in Table 37 Table 37 KVM Cable Product ID PID PID Description N20 BKVM KVM cable for B Series Blade Server console port Figure 16 KVM Cable 192621 Connector to server front panel VGA connector for monitor DB 9 serial connector Two port USB connector for a mouse and keyboard Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 69 SUPPLEMENTAL MATERIAL Motherboard USB and SD Ports
51. ections Network PCle Card Redundant Top of Rack Access Switches Network PCle Card Redundant Top of Rack Access Switches 32 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 8 ORDER POWER SUPPLY The C220 M4 SFF server accommodates two power supplies A lightly loaded server can operate from one 770 W power supply A fully loaded server might need to be powered with two 770 W power supplies see Table 14 Use the power calculator at the following link to determine the needed power based on the options chosen CPUs drives memory and so on https mainstayadvisor com Go Cisco Cisco UCS Power Calculator aspx Table 14 Power Supply PIDs Product ID PID PID Description UCSC PSU1 770W 710 W power supply o NOTE In a two power supply server both power supplies must be identical Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 33 CONFIGURING the SERVER STEP 9 SELECT AC POWER CORD s Using Table 15 select the appropriate AC power cords You can select a minimum of no power cords and a maximum of two If you select the option R2XX DMYMPWRCORD no power cord is shipped with the server Table 15 Available Power Cords Product ID PID PID Description Images R2XX DMYMPWRCORD No power cord dummy PID to Not applicable allow for a no power cord option
52. er CIMC firmware Depending on your CIMC settings the CIMC can be accessed through the 1 GbE dedicated management port the 1 GbE LOM ports or a Cisco virtual interface card VIC Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C220 M4 High Density SFF Rack Server m STEP 1 VERIFY SERVER SKU page 10 m STEP 2 SELECT CPU s page 11 m STEP 3 SELECT MEMORY page 13 m STEP 4 SELECT RAID CONFIGURATION page 18 B STEP 5 SELECT HARD DISK DRIVES HDDs or SOLID STATE DRIVES SSDs page 23 m STEP 6 SELECT PCle OPTION CARD s page 26 m STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 29 m STEP 8 ORDER POWER SUPPLY page 33 B STEP 9 SELECT AC POWER CORD s page 34 m STEP 10 ORDER RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM page 37 STEP 11 ORDER A TRUSTED PLAT FORM MODULE OPTIONAL page 38 m STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE OPTIONAL page 39 m STEP 13 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 40 m STEP 14 SELECT OPERATING SYSTEM MEDIA KIT page 43 m STEP 15 SELECT SERVICE and SUPPORT LEVEL page 44 m OPTIONAL STEP ORDER RACK s page 49 B OPTIONAL STEP ORDER PDU page 50 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 9 CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID PID of the
53. ital SD Card blank Product ID PID PID Description UCS SD 64G S 64 GB SD Card for UCS Servers Table 20 32 GB Secure Digital SD Card blank Product ID PID PID Description UCS SD 32G S 32 GB SD Card for UCS Servers Caveats B Install either one two 64 GB SD cards or or two 32 GB SD cards B Do not mix SD card sizes Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 39 CONFIGURING the SERVER STEP 13 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE Several operating systems and value added software programs are available Select as desired from Table 21 Table 21 OSs and Value Added Software for 2 CPU servers PID Description Product ID PID Microsoft Windows Server MSWS 08R2 STHV Windows Svr 2008 ST media R2 ST 1 4CPU 5CAL MSWS 08R2 ENHV MSWS 08R2 DCHV25S MSWS 12 ST25 MSWS 12 DC2S MSWS 12 ST2S NS MSWS 12 DC2S NS MSWS 12R2 ST2S MSWS 12R2 DC25 MSWS 12R2 ST2S NS MSWS 12R2 DC2S NS Windows Svr 2008 EN media R2 EN 1 8CPU 25CAL Windows Svr 2008 R2 2 CPU Data Center Windows Server 2012 Standard 2 CPU 2 VMs Windows Server 2012 Datacenter 2 CPU Unlimited VMs Windows Server 2012 Standard 2 CPU 2 VMs No Cisco SVC Windows Server 2012 Datacenter 2 CPU Unlim VM No Cisco SVC Windows Server 2012 R2 Standard 2 CPU 2 VMs Windows Server 2012 R2 Datacenter 2 CPU Unlimited VMs Windows Server 2012 R2 Standard 2 CPU 2 VMs No Cisco SVC Wind
54. ives supported per controller is as follows m Embedded RAID 8 m Cisco 12G SAS Modular RAID controller 64 The RAID controller choices are 1 Embedded Software RAID 5 Key Upgrade on motherboard NOTE The RAID configuration options listed in Table 7 on page 20 are not available if you choose the embedded software RAID 5 key upgrade in this case you must b configure RAID yourself using separate software 2 Cisco 12G SAS Modular RAID Controller The C220 M4 server has a dedicated RAID controller slot on the motherboard that accommodates the Cisco 12G SAS Modular RAID controller for internal HDDs SSDs Cisco can provide factory configured RAID setting options depending on the RAID controller chosen and the number of HDDs SSDs ordered Factory configured RAID level options are listed with each RAID card description 18 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Select RAID Options Select one of the following m Embedded software RAID 5 key upgrade option for internal drives see Table 6 or m Cisco 12G SAS modular RAID controller for internal drives plus optional flash backed write cache FBWC see Table 7 on page 20 or B Dual controllers One Cisco 12G SAS modular RAID controller for internal drives plus optional flash backed write cache FBWC and One Cisco 9300 8 12G SAS controller for external drives see Table 7 on p
55. ize speed capacity R2XX RAID10 Factory preconfigured RAID option Enable RAID 10 Setting Requires a even number of drives minimum of four drives of the same size speed capacity NOTE Although RAID levels 50 and 60 are not orderable from the factory they are supported for selected controllers as shown in Table 7 Approved Configurations The C220 M4 SFF server has an 8 drive backplane B The embedded software RAID 5 upgrade key option supports up to eight internal SATA only drives m The Cisco 12G SAS Modular RAID controller supports up to eight internal drives m The Cisco 12G SAS 9300 8e PCle external drive controller supports up to 8 external SAS SATA ports NOTE If you do not select a Cisco 12G SAS Modular RAID controller or the embedded software RAID 5 key upgrade option you will have an embedded SATA only RAID controller that supports up to eight SATA only drives RAID 0 1 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 21 CONFIGURING the SERVER See Table 8 for a summary of the supported RAID configuration options Table 8 Supported RAID Configurations Cisco 12G SAS Server CPUs Embedded RAID Modular RAID Controller y E Ec 9 C220 M4 SFF Enabled Not allowed Not allowed 8 8 internal SATA SATA 8 HDD only C220 M4 SFF Installed 8 HDD EN Not allowed onMotherboard rd absent 8 internal External PCle Drives Controller2 Supported
56. lio in a 1U form factor with the addition of the Intel Xeon E5 2600 v3 series processor family that deliver significant performance and efficiency gains In addition the UCS C220 M4 SFF server provides 24 DIMM slots up to 8 drives and 2 x 1 GbE LAN on motherboard LOM ports delivering outstanding levels of density and performance in a compact 1U package The C220 M4 SFF server includes a modular LAN on motherboard mLOM slot for installation of a Cisco Virtual Interface Card VIC or third party network interface card NIC without consuming a PCI slot in addition to 2 x 1 embedded on the motherboard These features combine to provide outstanding levels of internal memory and storage expandability along with exceptional performance The Cisco UCS C220 M4 SFF server can be used standalone or as part of the Cisco Unified Computing System which unifies computing networking management virtualization and storage access into a single integrated architecture enabling end to end server visibility management and control in both bare metal and virtualized environments Figure 1 Cisco UCS C220 M4 High Density SFF Rack Server Front View Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 3 DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the front view of the Cisco UCS C220 M4 High Density SFF Rack Server Figure 2 Chassis Front View
57. nce is optimized when the DIMM type and quantity are equal for both CPUs and when all channels are filled equally across the CPUs in the server m System speed is dependent on how many DIMMs are populated per channel and the CPU DIMM speed support See Table 5 for details Table 5 DIMM Memory Speeds with Different CPUs 1600 MHz 1600 MHz Capable CPU CPU 1866 MHz 1866 MHz Capable CPU CPU 2133 MHz 2133 MHz Capable CPU CPU DIMM Speed DPC RDIMM LRDIMM RDIMM dach TRE QR SR QR SR QR 2133 DIMM 1DPC 1600 1866 1866 2133 2DPC 1600 1866 1866 2133 3DPC 1600 1600 1600 1866 16 GB DIMMs 1600 8 GB DIMMs Notes 1 2133 MHz DIMMs are the only offered and supported DIMMs for the C220 M4 server B The C220 M4 server supports four different memory reliability availability and serviceability RAS modes Independent Channel Mode Mirrored Channel Mode Lockstep Channel Mode m Below are the system level RAS Mode combination limitations Mixing of Independent and Lockstep channel mode is not allowed per platform Mixing of Non Mirrored and Mirrored mode is not allowed per platform Mixing of Lockstep and Mirrored mode is not allowed per platform Do not mix RDIMMs with LRDIMMs Single rank DIMMs can be mixed with dual rank DIMMs in the same channel Do not mix quad rank DIMMs with single or dual rank DIMMs in the same channel For best performance obse
58. net for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco SMART net for UCS Hardware Only Service You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours SMART net for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is required You can choose a service listed in Table 24 Table 24 SMART net for UCS Hardware Only Service Service On Er Product ID PID Level GSP Site Description CON UCW7 C220M4SF UCW7 Yes UCS HW 24 7 405 UCS C220 M4 SFF CON UCW5 C220M4SF UCW5 Yes UC PLUS 8X5XNBDOS UCS C220 M4 SFF Unified Computing Partner Support Service Cisco Partner Support Service PSS is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers Cisco PSS provides partners with access to Cisco s support infrastructure and assets to help them m Expand their service portfolios to support the most complex network environments m Lower delivery costs m Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco intellectual assets This helps partner
59. ol less rail kit Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 37 CONFIGURING the SERVER STEP 11 ORDER A TRUSTED PLATFORM MODULE OPTIONAL Trusted Platform Module TPM is a computer chip microcontroller that can securely store artifacts used to authenticate the platform server These artifacts can include passwords certificates or encryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is listed in Table 18 Table 18 Trusted Platform Module Product ID PID PID Description UCSX TPM2 001 Trusted Platform Module 1 2 SPl based for UCS Servers NOTE The module used in this server conforms to TPM v1 2 1 3 as defined by the Trusted Computing Group TCG It is also SPl based 38 Cisco UCS C220 4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE OPTIONAL You can order 64 GB SD cards or 32 GB SD cards See Figure 6 on page 51 for the location of the SD cards There are two locations SD1 and SD2 Table 19 64 GB Secure Dig
60. ork Adapters CNAs UCSC PCIE E14102 Emulex 14102 dual port 10 FCoE CNA Host Bus Adapters HBAs N2XX AQPCIO5 UCSC PCIE Q2672 N2XX AEPCIO5 UCSC PCIE E16002 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Qlogic QLE2672 CSC 16Gb Fibre Channel HBA with SR Optics Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Emulex LPe16002 M6 16Gb Fibre Channel HBA with SR Optics UCS Storage Accelerators UCSC F FIO 1000PS UCSC F FIO 1300PS UCSC F FIO 2600PS UCSC F FIO 5200PS UCSC F FIO 3200SS UCSC F FIO 6400SS Notes 1 The mLOM cards do not plug into any of the riser 1 or riser 2 card slots instead they plug into a connector UCS 1000GB Fusion ioMemory3 PX Performance line for C Series UCS 1300GB Fusion ioMemory3 PX Performance line for C Series UCS 2600GB Fusion ioMemory3 PX Performance line for C Series UCS 5200GB Fusion ioMemory3 PX Performance line for C Series UCS 3200GB Fusion ioMemory3 SX Scale line for C Series UCS 6200GB Fusion ioMemory3 SX Scale line for C Series inside the server chassis 2 Amaximum of one storage accelerator card is supported and it must be installed in slot 1 only Note that the Cisco 12G SAS 9300 8e also can only be installed in slot 1 Approved Configurations 1 1 CPU Systems m You can select up to one PCie option card slot 1 for 1 CPU systems listed in Table 10 on page 26 2 2 CPU Systems B You can select up to two PCie option cards slots 1 and 2 for 2 CPU
61. ows Server 2012 R2 Datacen 2 CPU Unlim VM No Cisco Svc SUSE SLES SVR 25 16 1A SUSE Linux Enterprise Srvr SLES SVR 25 1G 3A SLES SVR 25 1G 5A SLES SVR 2S UG 1A SLES SVR 2S UG 3A SLES SVR 2S UG 5A SLES SHA 25 1A SLES SHA 25 3A SLES SHA 25 5A SLES HGC 25 1A SLES HGC 25 3A SLES HGC 25 5A SLES SAP 2S 1G 1A SLES SAP 2S 1G 3A SLES SAP 2S 1G 5A SLES SAP 2S UG 1A SLES SAP 2S UG 3A SLES SAP 2S UG 5A 40 1 2 CPU 1 Phys SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 5yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 3yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 5yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 1yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 3yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 5yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 1yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 3yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 5yr Support Reqd SLES for SAP Applications 1 2 CPU Unl Vrt 1yr Support Reqd 1yr Support Reqd 3yr Support Reqd 5yr Support Reqd 1yr Support Reqd 3yr Support Reqd v SLES for SAP Applications 1 2 CPU Unl 3yr Support Reqd
62. r UCS Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Cisco SMARTnet for UCS Service includes flexible hardware replacement options including replacement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment You can choose a desired service listed in Table 23 Table 23 Cisco SMART net for UCS Service Product ID PID On Site Description CON PREM C220M4SF Yes ONSITE 24X7X2 UCS C220 M4 SFF CON OSP C220M4SF Yes ONSITE 24X7X4 UCS C220 M4 SFF CON OSE C220M4SF Yes ONSITE 8X5X4 UCS C220 M4 SFF CON OS C220M4SF Yes ONSITE 8X5XNBD UCS C220 M4 SFF CON S2P C220M4SF No SMARTNET 24X7X2 UCS C220 M4 SFF CON SNTP C220M4SF SMARTNET 24X7X4 UCS C220 M4 SFF CON SNTE C220M4SF No SMARTNET 8X5X4 UCS C220 M4 SFF CON SNT C220MASF NO SMARTNET 8X5XNBD UCS C220 M4 SFF 44 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER SMART
63. r soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data Table 4 Available DDR4 DIMMs Product ID PID PID Description DIMM Options UCS ML 1X324RU A 32GB DDR4 2133 MHz LRDIMM PC3 17000 quad rank x4 UCS MR 1X162RU A 16GB DDR4 2133 MHz RDIMM PC3 17000 dual rank x4 UCS MR 1X081RU A 8GB DDR4 2133 MHz RDIMM PC3 17000 single rank x4 Memory Mirroring Option NO1 MMIRROR Memory mirroring option Approved Configurations 1 1 CPU configuration without memory mirroring Voltage E 1 2 V 4 1 2 V 2 1 2 V 1 m Select from 1 to 12 DIMMs Refer to Memory Population Rules page 53 for more detailed information 14 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER 2 1 CPU configuration with memory mirroring m Select 2 4 6 8 or 12 identical DIMMs The DIMMs will be placed by the factory as shown in the following table Total CPU 1 DIMM Placement in Channels Number for identical dual rank DIMMs for 3DPC or identical quad rank DIMMs for 2DPC Blue Slots Black Slots White Slots 2 A1 B1 4 A1 B1 C1 D1 E 6 A1 B1 C1 A2 B2 C2 8 A1 B1 C1 D1 A2 B2 C2 D2 12
64. re 5 Standard for 1 Processor 4 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd VMware vSphere 5 Enterprise for 1 Processor 1 Year Support VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support VMware vSphere 5 Enterprise for 1 Processor 4 Year Support VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rad VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMware vSphere 5 Enterprise Plus for 1 Processor 5 Year Support Rqd VMware vCenter 5 Server Standard 1 yr support required VMware vCenter 5 Server Standard 2 yr support required VMware vCenter 5 Server Standard 3 yr support required VMware vCenter 5 Server Standard 4 yr support required VMware vCenter 5 Server Standard 5 yr support required Acceptance of Terms Standalone VMW License for UCS Servers Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 14 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 22 Table 22 OS Media Product ID PID RHEL 6 SLES 11 MSWS 08R2 STHV RM MSWS 08R2 ENHV RM MSWS 08R2 DCHV RM MSWS 12 ST2S RM MSWS 12 DC2S R
65. rives listed in Table 9 See SELECT RAID CONFIGURATION page 18 for more details Caveats m You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all SSDs in their own RAID volume Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 25 CONFIGURING the SERVER STEP 6 SELECT PCle OPTION CARD s The standard PCie card offerings are Modular LAN on Motherboard mLOM Virtual Interface Cards VICs Network Interface Cards NICs Converged Network Adapters CNAs Host Bus Adapters HBAs UCS Storage Accelerators Select PCle Option Cards The available PCle option cards are listed in Table 10 Table 10 Available PCle Option Cards Product ID PID PID Description ar Modular LAN on Motherboard mLOM UCSC MLOM CSC 02 Cisco UCS VIC1227 VIC MLOM Dual Port 10Gb SFP N A Virtual Interface Cards VICs UCSC PCIE CSC 02 Cisco VIC 1225 Dual Port 10Gb SFP CNA Half UCSC PCIE C10T 02 Cisco VIC 1225T Dual Port 10GBaseT CNA Half Network Interface Cards NICs 1 Gb NICs UCSC PCIE IRJ45 Intel i350 Quad Port 1Gb Adapter Half 10 Gb NICs N2XX AIPCIO1 Intel X520 Dual Port 10Gb SFP Adapter Half UCSC PCIE ITG Intel X540 Dual Port 10GBase T Adapter Half 26 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER Table 10 Available PCle Option Cards continued Product ID PID PID Description 10 Gb Converged Netw
66. roadcom 5709 Dual Port Ethernet PCle Adapter for M3 Yes No No Servers N2XX ABPCIO3 M3 Broadcom 5709 Quad Port 10 100 1Gb NIC w TOE iSCSI for M3 Use RJ45 Ethernet cable Servers d Use Intel SFP Intel X520 Dual Port 10Gb SFP Adapter UCSC PCIE ITG Intel X540 Dual Port 10GBase T Adapter UCSC PCIE IRJ45 Intel i350 Quad Port 1Gb Adapter Use RJ45 Ethernet cable UCSC PCIE BTG Yes No No Broadcom 57712 Dual Port 10GBASE T w TOE iSCSI Host Bus Adapters HBAs N2XX AEPCIO3 Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA EN Preinstalled do not change SFP N2XX AEPCIOS Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Preinstalled do not change SFP N2XX AQPCIO3 QLogic QLE2462 Dual Port 4Gb Fibre Channel HBA EN Preinstalled do not change SFP Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 31 PCle Cards CONFIGURING the SERVER Table 13 PCle Card Compatibility continued Cisco SFP Modules PCle Cards Twinax Cables SFP 10G SR DS SFP FC8G SW N2XX AQPCIO5 QLogic QLE2562 Dual Port 8Gb Fibre Channel HBA EN Preinstalled do not change SFP UCSC PCIE Q2672 Qlogic QLE2672 CSC 16Gb Fibre Channel HBA with SR Optics EN Preinstalled do not change SFP UCSC PCIE E16002 Emulex LPe16002 M6 16Gb Fibre Channel HBA with SR Optics EN Preinstalled do not change SFP Notes 1 This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable Figure 5 Network Card Conn
67. roller Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 59 SUPPLEMENTAL MATERIAL To Create a RAID Group 1 While the server is booting wait for the prompt and press function key F2 as shown in Figure 10 Function Key F2 Prompt TTE Cisco Press F2 Setup lt F6 gt Boot Menu F7 Diagnostics lt Fa gt Cisco IMC Contiguration Fi2 gt Network Boot Bios Version Ce40M4 2 0 9 0 080720142705 Platform ID C24OM4 Cisco IMC IPvd Address 172 29 2285 92 Cisco IMC HAC Address 4 0 1B 1E 68 CO Processor s Intel R KeontR CPU EBb 264d0 v3 2 60GH2 Total Memory 128 GB Effective Memory 128 GB Memory Operating Speed 1866 Mhz In a few seconds you will see the screen that allows you to set up a RAID group for the primary SATA controller see Figure 11 Screen to Configure Primary SATA RAID Group 151 1 Software RAID BIOS Version A 14 05201544K LSI SATA RAID Found at PCI Bus No 00 Dev Ho 1F Device present at port 0 oT 31Gb 4085 95335 7MB Device present at port 1 ar231000640H5 953357 Device present at port 2 3T310600640H5 353357 HB Device present at port 3 3T31000640H5 353357 HB 01 Virtual drive s Configured Arrayt Mode stripe Size Stripes Drivesize Status RAID 10 04 1905440HB Press Ctrl M or Enter to run LSI Software RAID Setup Utility 60 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive
68. rve the following DIMMs with different timing parameters can be installed on different slots within the same channel but only timings that support the slowest DIMM will be applied to all 16 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER As a consequence faster DIMMs will be operated at timings supported by the slowest DIMM populated When one DIMM is used it must be populated in DIMM slot 1 farthest away from the CPU of a given channel When single dual or quad rank DIMMs are populated for 2DPC or 3DPC always populate the higher number rank DIMM first starting from the farthest slot For a 3DPC example first populate with quad rank DIMMs in the DIMM slot 1 Then dual rank DIMMs in the DIMM 2 slot Then single rank DIMMs in the DIMM 3 slot B DIMMs for CPU 1 and CPU 2 when populated must always be configured identically B When using mirroring DIMMs must be installed in identical pairs across paired DDR4 buses That is mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical However the DIMMs used in channels A and B can be different from those in channels C and D B Memory mirroring reduces the amount of available memory by 50 quantity of DIMMs must be even for mirroring B Non ECC DIMMs are not supported B Pairs of DIMMs A1 B1 A2 B2 etc MUST be the exact same same PID rev DIMM loading order
69. s to realize higher margins and expand their practice PSS is available to all Cisco PSS partners but requires additional specializations and requirements For additional information see the following URL www cisco com go partnerucssupport The two Partner Unified Computing Support Options include m Partner Support Service for UCS m Partner Support Service for UCS Hardware Only Partner Support Service for UCS provides hardware and software support including triage support for third party software backed by Cisco technical resources and level three support Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 45 CONFIGURING the SERVER See Table 25 Table 25 Partner Support Service for UCS Service P Product ID PID Level Description Site GSP CON PSJ1 C220M4SF PSJ1 No UCS SUPP PSS 8X5XNBD UCS C220 M4 SFF CON PSJ2 C220M4SF PSJ2 No UCS SUPP PSS 8X5X4 UCS C220 M4 SFF CON PSJ3 C220M4SF PSJ3 No UCS SUPP PSS 24X7X4 UCS C220 M4 SFF CON PSJ4 C220M4SF PSJ4 No UCS SUPP PSS 24X7X2 UCS C220 M4 SFF Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours See Table 26 Table 26 Partner Support Service for UCS Hardware Only Product ID PID om ie Description CON PSW2 C220M4SF PSW2 No UCS W PL PSS 8X5X4 UCS C220 M4 SFF CON PSW3 C220M4SF PSW3 No UCS W PL PSS 24X7X4 UCS C220 M4 SFF CON PSW4 C220M4SF PSW4 No UCS W PL PSS 24X7X2 UCS C
70. stem ACPI Fans Integrated management processor The mLOM slot can flexibly accommodate the following cards m Cisco Virtual Interface Cards VIC Quad Port Intel 1350 1GbE RJ45 Network Interface Card NIC NOTE The four Intel i350 ports are provided on an optional card that plugs into the slot and are separate from the two embedded on the motherboard LAN ports m Rear panel e One DB15 VGA connector e One RJ45 serial port connector e Two USB 3 0 port connectors e One RJ 45 10 100 1000 Ethernet management port using Cisco Integrated Management Controller CIMC firmware e Two Intel i350 embedded on the motherboard GbE LOM ports e One flexible modular LAN on motherboard mLOM slot that can accommodate various interface cards m Front panel e One KVM console connector supplies two USB 2 0 connectors one VGA DB15 connector and one serial port RS232 RJ45 connector B Various PCle card ports dependent on which cards are installed e Virtual Interface Card VIC ports e Converged Network Adapter CNA ports e Network Interface Card NIC ports e Host Bus Adapter HBA ports Up to two 770 W AC hot swappable power supplies One is mandatory one more can be added for 1 1 redundancy This server supports the advanced configuration and power interface ACPI 4 0 standard Chassis m Six hot swappable fans for front to rear cooling BMC running Cisco Integrated Management Controll
71. systems listed in Table 10 on page 26 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model Card Height Half Half Half Half Half Half Half Half Full Half Full 27 CONFIGURING the SERVER Caveats A maximum of one storage accelerator card is supported and it must be installed in slot 1 only Note that the Cisco 12G SAS 9300 8e also can only be installed in slot 1 Therefore the system can support either one storage accelerator card or one Cisco 12G SAS 9300 8e but not both at the same time For 1 CPU systems Only the full height PCle slot on riser 1 slot 1 is supported Only a single plug in PCle VIC card is supported and must be installed in slot 1 the full height slot However in addition to the one PCle VIC card you can also choose to install an mLOM VIC card If any of the Storage Accelerator cards are installed they can be installed only in slot 1 For 2 CPU systems Both PCle slots slots 1 and 2 are supported Only a single plug in PCle VIC card is supported and it must be installed in slot 1 the full height slot However in addition to the one PCle VIC card you can also choose an mLOM VIC card If any of the Storage Accelerator cards are installed they can be installed only in slot 1 Other considerations for the Cisco VIC 1225 1227 1225T cards VIC 1225 and VIC 1227 Supports 10G SFP optical and copper twinax connections VIC 1225T Supports RJ45 Ca
72. tegory 6 or better twisted pair cable connections The server supports installation of one PCle Cisco VIC 1225 1225Tcard and it is supported only in PCle slot 1 For the Cisco UCS VIC1225 requires that the server has CIMC firmware version 1 4 6 or later installed and VIC firmware of 2 1 0 or later For the Cisco UCS VIC1225T requires that the server has CIMC firmware version 1 5 1 or later installed and VIC firmware of 2 1 1 or later B help ensure that your operating system is compatible with the card you have selected or to see additional cards that have been qualified to work with the UCS C220 M4 server but are not sold on the Cisco pricelist check the Hardware Compatibility List at this URL 28 http www cisco com en US products ps10477 prod technical reference list html Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two port network cards that are available with the server Choose Optional Twinax Cables Table 11 lists the copper twinax cables available for the PCle cards You can choose cable lengths of 1 3 5 7 or 10 meters The two longer cables 7 and 10 meters are active which means that they contain active components within the SFP housing to improve signal quality Table 11 Available Twinax Cables Product ID PID PID
73. tes per day UCS SD16T1252 EP Drive PID Description Type 1 6 TB Enterprise Performance 12 Gbps SAS eMLC SSD Toshiba SAS UCS SD800GOKS2 EP 800 GB Enterprise Performance 6 Gbps SAS eMLC SSD Samsung SAS UCS SD400G12S2 EP 400 GB Enterprise Performance 12 Gbps SAS eMLC SSD Toshiba SAS UCS SD400GOKS2 EP 400 GB Enterprise Performance 6 Gbps SAS eMLC SSD Samsung SAS UCS SD200GOKS2 EP 200 GB Enterprise Performance 6 Gbps SAS eMLC SSD Samsung SAS Enterprise Value SSDs endurance of up to 1 FDWP full drive write per day 2 UCS SD960GOKS2 EV 960 GB 2 5 inch Enterprise Value 6 Gbps SAS SSD SATA UCS SD480GOKS2 EV 480 GB 2 5 inch Enterprise Value 6 Gbps SAS SSD SATA UCS SD240GOKS2 EV 240 GB 2 5 inch Enterprise Value 6 Gbps SAS SSD SATA UCS SD120GOKS2 EV 120 GB 2 5 inch Enterprise Value 6 Gbps SAS SSD SATA Notes Capacity 1 6 TB 800 GB 400 GB 400 GB 200 GB 960 GB 480 GB 240 GB 120 GB 1 Targeted for IO write centric applications Supports endurance of 10 FDWP full drive writes per day Target applications are caching online transaction processing OLTP data warehousing and virtual desktop infrastructure VDI 2 Targeted for IO read centric applications Supports endurance of 1 FDWP full drive writes per day Target applications are boot streaming media and collaboration NOTE When creating each RAID volume follow these guidelines m Use the same capacity for each drive in each RAID volume m Use
74. tion Program Name Level GSP Service Level Product ID PID SMART net for UCS UCSD7 24x7x4 Onsite CON UCSD7 C220M4SF Service with Drive UCS DR Retention UCSD5 8x5xNBD Onsite CON UCSD5 C220M4SF Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model 47 48 CONFIGURING the SERVER Table 28 Drive Retention Service Options continued M Service Service Service Description Program Name Level GSP Service Level Product ID PID SMART net for UCS UCWD7 24x7x4 Onsite CON UCWD7 C220M4SF HW ONLY Drive UCS HW DR Retention UCWD5 8x5xNBD Onsite CON UCWD5 C220M4SF For more service and support information see the following URL http www cisco com en US services ps2961 ps10312 Unified Computing Services Overview pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv_group_home html Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model OPTIONAL STEP ORDER RACK s OPTIONAL STEP ORDER RACK s The optional R42610 rack is available from Cisco for the C Series servers including the C220 M4 SFF server This rack is a standard 19 inch rack and can be ordered with a variety of options as listed in Table 29 Racks are shipped separately from the C220 M4 SFF server Table 29 Racks and Rack Options Product ID PID RACK UCS RACK UCS2 RACK BLANK 001 RACK CBLMGT 001 RACK CBLMGT 011 R
75. tsinks Motherboard Lithium Battery You can order a replacement motherboard battery Installation instructions are found at this link http www cisco com c en us td docs unified_ computing ucs c hw C220M4 install C220M4 html See the section titled Replacing the Motherboard RTC Battery Thermal Grease with syringe applicator for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink Instructions for applying thermal grease are found at http www cisco com c en us td docs unified computing ucs c hw C220M4 install C220M4 html See the section titled Replacing CPUs and Heatsinks CAUTION Use only the thermal grease specified for this server AA UCS CPU GREASE3 This thermal grease comes in a white tipped syringe and is to be used only in the C220 M4 and C240 servers Other servers use thermal grease in a blue tipped syringe UCS CPU GREASE Thermal grease for other systems may have different thermal conductivity properties and may cause overheating if used in the C220 M4 or C240 M4 servers DO NOT use thermal grease available for purchase at any commercial electronics store If these instructions are not followed the CPU may overheat and be destroyed NOTE When you purchase a spare CPU the thermal grease with syringe applicator is included 64 Cisco UCS C220 M4 High Density Rack Server Small Form Factor Disk Drive Model