Home
JY997D24901A INSTALLATION MANUAL
Contents
1. Assigned O Not assigned 2 Installation SAE CAIRIONG lt gt DANGER e Cut off all phases of the power supply externally before installation or wiring work in order to avoid damage to the product or electric shock INSTALLATION PRECAUTIONS CAUTION e Use the product within the generic environment specifications described in the PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or exposed to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur Install the product securely using the DIN rail or screws Install the product on a flat surface If the mounting surface is rough undue force will be applied to the PC board thereby causing nonconformity When drilling screw holes or wiring make sure cutting or wiring debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Be sure to remove the dust proof sheet from the PLC s ventilation port when installation work is completed Failure to do so may cause fire equipment failures or malfunctions Connect the extension cables and communication cables securely to the designated connectors Contact failures may cause malfunctions Do not touch the conductive part
2. Requirement for the compliance with EMC directive The following product complies with the European Directive 89 336 EEC Electromagnetic Compatibility by the direct testings based on the following standard and design analysis by creating a technical construction file when the following devices s application follows the directions in this document Type Programmable Controller Open Type Equipment Models MELSEC FX3u series manufactured from March 1st 2007 FX3U 32DP Standard EN61131 2 2003 Programmable controllers Equipment requirements and tests Tests The corresponding items are tested on the 32DP as follows e Radiated Emissions e Mains Terminal Voltage Emissions e RF immunity e Fast Transients e ESD e Conducted e Surge e Power magnetic fields Cautions for compliance with EC Directive 1 Wiring To avoid malfunctions by noise lay the twisted pair PROFIBUS cable so that more than 50 mm 1 97 is touching the grounding plate connected to the ground terminal For details on wiring refer to Section 3 2 2 Installing in an enclosure For detail on installing in an enclosure refer to FX3U User s Manual Hardware Edition 1 Introduction The FX3U 32DP PROFIBUS DP Interface Block hereinafter called 32DP enables users to integrate the MELSEC FX3u PLC into any existing PROFIBUS DP network DP V0O DP V1 as a DP Slave The 32DP links the FX3u PLC with PROFIBUS DP decentralized control tasks
3. e Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise 1 Do not bundle the main circuit line together with or lay it close to the main cir cuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit high voltage line or load line 2 Ground the shield wire or shield of the shielded cable at one point on the PLC However do not ground them at the same point as the high voltage lines e Install module so that excessive force will not be applied to the connectors Failure to do so may result in wire damage breakage or PLC failure STARTUP AND MAINTENANCE DANGER PRECAUTIONS e Do not touch any terminal while the PLC s power is on Doing so may cause electric shock or malfunctions Before cleaning or retightening terminals externally cut off all phases of the power supply Failure to do so may cause electric shock Before modifying or disrupting the program in operation or running the PLC carefully read through this manual and the associated manuals and ensure the safety of the operation An operation error may damage the machinery or cause accidents STARTUP AND MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the PLC Doing s
4. e Special Unit Block No Label Included Items 1 2 External Dimensions and Part Names Dimensions mm inches MASS Weight Approx 0 2kg 0 44 Ibs 3 4 5 6 RUN O TOKEN O FROM TO O DIAO POWER 80 3 15 90 3 55 87 3 43 89 3 51 1 PROFIBUS DP port 9 pin D SUB Connector 4 40unc inch screw thread 2 Extension cable 3 Direct mounting hole 2 holes of 64 5 0 18 mounting screw M4 screw 4 Status LED LED Name Color Description ON Correct power supply from the PLC POWER Green For other status refer to FX3U 32DP User s Manual FROM TO Green ON Constant FROM TO access within 200ms intervals ON In cyclic data exchange mode RUN Green Flashing DP Master is in clear mode or DP Slave is in Fail Safe state OFF Normal Operation without errors Otherwise An error detected For error details refer to FX3U 32DP User s Manual DIA TOKEN Green ON Estabilished connection with the DP Master 5 Extension port under the top cover 6 Name plate 7 DIN rail mounting groove DIN rail DIN46277 8 DIN rail mounting hook 1 3 Pin configuration of PROFIBUS DP Connector The connector is a 9 pin D SUB 4 40unc inch screw thread type with the following pin assignment Signal Name Meaning RXD TXD P Receive Transmit Data P Ready to send DGND Data Ground Voltage Plus 5V 90mA RXD TXD N Receive transmit Data N Pin not assigned
5. The module connects the PLC system to the DP Master in the PROFIBUS DP network for efficient and easy data exchange 1 Easy Connectivity to an existing PROFIBUS DP Network The 32DP enables the FX3U PLC to fit into an existing PROFIBUS DP Network as a DP Slave while reducing the time and cost for users to build up a new network system 2 Enhanced Data Exchange The 32DP has enhanced the data exchange functionality in the following communication formats e Cyclic I O data a maximum of 144 Bytes e Acyclic I O Data a maximum of 140 Bytes e User Diagnostic Messages e Alarm Status Messages 3 Global control The 32DP supports SYNC UNSYNC FREEZE UNFREEZE global controls 4 Flexible and Easy Network Setting The 32DP enables a flexible and smooth integration with components on a new existing PROFIBUS DP Network The FX3U 32DP PROFIBUS Interface Block is fully applicable for the user specific PROFIBUS DP Network For operation details of software GX Configurator DP Software Manual 5 Various Communication Speed Options The 32DP supports the communication speeds 9 6k 19 2k 45 45k 93 75k 187 5k 500k 1 5M 3M 6M and 12Mbps to fit into various kinds of networks To connect the 32DP to a PROFIBUS DP Network use the standard 9 pin D SUB connector and shielded twisted pair PROFIBUS cable complying with EN50170 1 1 Incorporated Items Product FX3U 32DP PROFIBUS DP Interface Block e Manual e Dust Proof Sheet e GSD file CD ROM
6. 984 400 m 1 312 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840
7. CHIYODA CHO HIMEJI JAPAN
8. GN PRECAUTIONS Z CAUTION e Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise 1 Do not bundle the main circuit line together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit high voltage line or load line 2 Ground the shield wire or shield of the shielded cable at one point on the PLC However do not ground them at the same point as the high voltage lines e Install module so that excessive force will not be applied to the peripheral device connectors Failure to do so may result in wire damage breakage or PLC failure WIRING PRECAUTIONS lt SDANGER e Cut off all phases of the power supply externally before installation or wiring work in order to avoid damage to the product or electric shock WIRING PRECAUTIONS Z CAUTION e When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions 3 1 Applicable Cable and Connector The following table shows the applicable cable and connector for a PROFIBUS DP network Item Description PROFIBUS DP network cable Shielded twisted pair
9. JY997D24901A ae MITSUBISHI PROGRAMMABLE CONTROLLERS MELSEG F Changes for the Better FX3U 32DP INSTALLATION MANUAL Manual Number JY997D24901 F X 3u Before installation operation maintenance or inspection of this product thoroughly read through and understand this manual and the associated manuals Also take care to handle the module properly and safely Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective March 2007 Specifications are subject to change without notice 2007 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories KOBANGER and REGGE Indicates that incorrect handling may cause hazardous lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also cause severe injury It is important to follow all precautions for personal safety Associated Manuals JY997D16501 MODEL CODE 09R516 Manual name Description FX3U Series User s Manual Hardware Edition De
10. PROFIBUS cable complying with EN50170 Applicable only to PROFIBUS connector 9 pin D SUB Connector 4 40unc inch screw thread For PROFIBUS connectors see the PROFIBUS connector manual Connector 3 2 Wiring To connect the 32DP to a PROFIBUS DP network use the PROFIBUS connector and shielded twisted pair PROFIBUS cable complying with EN50170 Shielded twisted PROFIBUS connector m pair PROFIBUS cable to DOO i PROFIBUS DP network FX3uU 32DP PROFIBUS DP Interface Block For noise prevention please attach at least 50 mm 1 97 of the twisted pair PROFIBUS cable along the grounding plate to which the ground terminal is connected FX3uU 32DP PROFIBUS DP Interface Block FX3U Series PLC Shielded twisted pair PROFIBUS cable complying with EN50170 to Profibus DP network Grounding plate Grounding resistance of 100 Q or less Class D 3 3 Grounding Ground the cable as stated below e Use a grounding resistor of 100Q or less e Ground the cables indepently for best results When independent grounding is not used use shared grounding as follows For details refer to the FX3U Series User s Manual Hardware Edition Independent grounding Best condition Common grounding Not allowed Shared grounding Good condition e The grounding wire size should be AWG 14 2 mm or larger e The grounding point should be as close to the PLC as possible and all grou
11. nding wire should be as short as possible 3 4 Bus Terminator To avoid the signal reflections connect a self terminating DP Connector Device at each end of the PROFIBUS DP Network Note The FX3U 32DP is not sef terminated 4 Specifications DESIGN PRECAUTIONS DANGER Make sure to have the following safety circuits outside of the PLC to ensure safe system operation even during external power supply problems communication errors or PLC failure Otherwise malfunctions may cause serious accidents 1 Most importantly have the following an emergency stop circuit a protection circuit an interlock circuit for opposite movements such as normal vs reverse rotation and an interlock circuit to prevent damage to the equipment at the upper and lower positioning limits Note that when the PLC CPU detects an error such as a watchdog timer error during self diagnosis all outputs are turned off Also when an error that can not be detected by the PLC CPU occurs in an input output control block output control may be disabled External circuits and mechanisms should be designed to ensure safe machinery operation in such a case Note that when an error occurs in a relay triac or transistor output device the output could be held either on or off For output signals that may lead to serious accidents external circuits and mechanisms should be designed to ensure safe machinery operation in such a case DESIGN PRECAUTIONS NCAUTION
12. o may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric distributor e Do not drop the product or expose the product to strong impacts as doing so may cause product damage e Turn off the power to the PLC before connecting or disconnecting any extension cable Failure to do so may cause equipment failures or malfunctions DISPOSAL PRECAUTIONS CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal process for your device TRANSPORT AND STORAGE PRECAUTIONS CAUTION e The 32DP is a precision instrument During transportation avoid any impact Verify the operations of the 32DP after transportation 4 1 Applicable PLC Model name Applicability FX3U Series PLC Ver 2 21 or later 4 2 General Specifications For the general specification refer to the PLC main unit manual The FX3U PLC s general specifications except the following items are applicable to the 32DP specifications However do not perform any dielectric withstand voltage tests or insulation resistance tests on this product Refer to FX3U Series User s Manual Hardware Edition Item Specifications Conformance to JEM 1021 500V AC for 1 min between communication 5 MQ or more by 500V DC connector frame and ground Insulation tester terminal of PLC main unit Withstand voltage Insulation resistance 4 3 P
13. ower Supply Specifications Description Internal Power Supply 145 mA at 24V DC is supplied from the internal service power in the main unit via extension cable 4 4 Performance Specifications Item Specifications Bus network PROFIBUS DP Slave Transmission Type Unit Type Transmission Data Maximum Exchanged Data Length e Cyclic Data 144 Byte e Acyclic Data 140 Byte Maximum Number of FX3U 32DP at one PLC 9 6k 19 2k 45 45k 93 75k 1 200 m 3 937 segment Supported Transmission 187 5k 1 000 m 3 281 segment 8 units speed bps sok 400 m 1 312 segment See Section 4 5 and Bus Length 145M 200 m 656 segment 3M 6M 12M 100 m 328 segment PROFIBUS Module ID F332 hex PROFIBUS DP Connector Network PROFIBUS DP network 9 pin D SUB Supports SYNC UNSYNC FREEZE and UNFREEZE modes Not built in Global Control Terminal Resistor 4 5 Maximum Bus Length and Baud Rate The following table shows the acceptable bus length Maximum Bus Length No of repeaters 1 Bus Length segment Maximum Bus Length Baud Rate on 1 200 m 2 400 m 3 600 m 4 800 m e MA 3 937 7 874 11 811 15 748 E 1 000 m 2 000 m 3 000 4 000 m 3 281 6 562 9 843 13 123 sank 400 m 800 m 1 200 m 1 600 m 1 312 2 625 3 937 5 249 1 5M 200 m 656 400 m 1 312 600 m 1 969 800 m 2 625 3M 6M 12M 100 m 328 200 m 656 300 m
14. s of the product directly to avoid failure or malfunctions 2 1 Installation Arrangements The 32DP is connected to the extension port of an FX3U series PLC or extension unit block including special function unit block on the right side Since additional extension devices can be added on both the left and right hand sides of the PLC keep an appropriate amount of space on both sides of the PLC when planning to add extension devices in the future For further details on installation arrangements refer to the following manual gt FX3u Series User s Manual Hardware Edition 2 2 Mounting The 32DP can be mounted on a DIN rail DIN46227 or mounted directly to the mounting surface with screws FX3U 32DP User s Manual FX3U Series User s Manual Hardware Edition 2 2 1 Direct Mounting The 32DP can be directly mounted with M4 screws An interval space of 1 to 2 mm 0 04 to 0 08 between each unit is necessary For details on the mounting hole pitch refer to Section 1 2 2 2 2 DIN Rail Mounting The 32DP can be mounted on a DIN rail DIN46227 35mm width 1 Fit the upper edge of the DIN rail mounting groove right fig A onto the DIN rail 2 Push the product onto the DIN rail 3 Connect the 32DP s extension cable to the extension port of the main unit I O extension unit block or special function unit block FX3U Series User s Manual Hardware Edition WWNIVIDD AWNNANNNH 3 Wiring DESI
15. scribes FX3U Series PLC specification details for I O wiring installation and maintenance FX3U FX3UC Series Programming Manual Basic amp Applied Instruction Edition JY997D16601 MODEL CODE 09R517 Describes PLC programming for basic applied instructions and devices FX3U 32DP User s Manual Describes details for the FX3U JY997D25201 32DP PROFIBUS DP Interface Block i e wiring installation specification and BFM allocations Describes details for the FX3u JY997D19201 64DP M PROFIBUS DP Master Block i e wiring installation specification and BFM allocations GX Configurator DP Describes the operation of GX Configuration System Configurator DP Configuration for Open Networks System for Open Networks Software Manual Software How to obtain manuals For product manuals or documents contact with the Mitsubishi Electric dealer you purchased your product FX3U 64DP M User s Manual Certification of UL cUL standards The following product has UL and cUL certification UL cUL File Number E95239 Models MELSEC FX3u series manufactured FX3U 32DP Compliance with EC directive CE Marking This document does not guarantee that a mechanical system including this product will comply with the following standards Make sure to have a user system engineer check the entire mechanical systems comformity to the EMC and LVD directives For more details please contact your local Mitsubishi Electric branch office
Download Pdf Manuals
Related Search
Related Contents
La lutte contre les trypanosomoses animales pour une Memorex Travel Speaker Virtual Terminal User Manual パソPOSG7MK Ⅱ XP EX-2 Chromalox A-129 User's Manual PT-31XL y PT-31XLPC - ESAB Welding & Cutting Products PONCEUSE POUR MURS 4 fonctions en 1 京滋の医療機関分 Toshiba Satellite L70D-A-009 MANUAL DE INSTRUCCIONES Y MONTAJE Copyright © All rights reserved.