1. CMT SVR series Installation Instruction Installation and Startup Guide This document covers the installation of cMT SVR Series for the detailed specifications and operation please refer to Brochure and EasyBuilder Pro User Manual Install Environment The cMT SVR Series has been tested to conform to European CE requirements Electrical This means that the circuitry is designed to resist the effects of electrical noise Environment This does not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Make sure that the units are installed correctly and that the operating limits are followed Avoid installing units in environments where severe mechanical vibration or shocks are present Do not operate the unit in areas subject to explosion hazards due to Environmental flammable gases vapors or dusts Considerations Do not install the unit where acid gas such as SO2 exists This device should be mounted in the vertical position and for use on the flat surface enclosure Conform to UL508 ISBN 0 7629 0404 6 machine safety for use in Pollution Degree 2 Environment Unpacking the Unit NOTE Place the unit on a stable surface during installation Dropping it or letting it fall may cause damage Unpack and check the delivery If damage is found notify the supplier 1 Installation Instruction A4 double sided 1 q 2 Power Connector 1 3 cMT SVR 1 In
2. Data 5 GND Signal Ground 6 Rx Data Rx 7 Rx Data Rx 8 TX Tx 9 Tx Tx pip sw settings COM3 RS 485 aw Data Data np EMEA When SW1 is turned ON and power the H H unit again the IP setting is restored to Normal Mode default ae 2 ON OFF Restore Ethernet IP Settings Ethernet 1 DHCP Ethernet 2 192 168 100 1 OFF ON Boot Loader Mode ON ON Restore Factory Default When restore factory default the projects and data stored in the unit are all cleared CAUTION NOTE Make sure that all local and national electrical standards are met when installing the unit Contact your local authorities to determine which codes apply The unit can be powered by DC power only voltage range 24 20 Volts DC compatible with A N Power most controller DC systems The power conditioning circuitry inside the unit is accomplished by a switching power supply The peak starting current can be as high as 500mA DC voltage sources should provide proper isolation from main AC power and similar hazards High Voltage Emergency A Hard wired EMERGENCY STOP should be fitted in any system using cMT SVR to comply with Stop ICS Safety Recommendations Supply Do not power the unit and inductive DC loads or input circuitry to the controller with the same Voltage power supply Note The 24 VDC output from some controllers may not have enough current to Condition power the unit Wire a Power wire length should be minimized M
3. ax 500m shielded 300m unshielded Routing b Please use twisted pair cables for power wire and signal wire and conform to the impedance matching c If wiring is to be exposed to lightning or surges use appropriate surge suppression devices d Keep AC high energy and rapidly switching DC power wiring separated from signal wires e Add a resistor and capacitor in the parallel connection between the ungrounded DC power supply and the frame ground This provides a path for static and high frequency dissipation Typical values to use are 1M Ohm and 4700pF Hardware The system designer should be aware that devices in Controller systems could fail and thereby Considerations create an unsafe condition Furthermore electrical interference in an operator interface can lead to equipment start up which could result in property damage and or physical injury to the operator If you use any programmable control systems that require an operator be aware that this potential safety hazard exists and take appropriate precautions Although the specific design steps depend on your particular application the following precautions generally apply to installation of solid state programmable control devices and conform to the guidelines for installation of Controllers recommended in NEMA ICS 3 304 Control Standards To conform with ICS Safety Recommendations checks should be placed in the controller to ensure Programming that all writable registers that cont
4. rol critical parts of plant or machinery have limit checks built into AN Considerations the program with an out of limit safe shut down procedure to ensure safety of personnel GMECSVROO_cMT_SVR _Installation_ 130722 Limited Warranty This product is limited warranted against defects in design and manufacture The proven defective product will either be repaired or replaced at Weintek s discretion This warranty shall not cover any product which is a Out of warranty period which is 12 months from the manufacturing month of the HMI products o Damage caused by Force Majeure accident negligence improper installation or misuse c Product has been repaired or taken apart by unauthorized technicians d Products whose identification markings have been removed or damaged
5. stallation Instructions Rail mounting DIN rail 35mm Panel mounting Use two M4 or 8 panhead screws mounting hole size is 4 6mm Power Connections NOTE Connect positive DC line to the terminal and the DC ground to the terminal To make a connection strip about 3 8 of insulation off the end of the wire turn the connector screw counterclockwise until the gap is wide open insert the wire all the way in and adi turn the screw clockwise until it s tight TTO 24VDC FG System Settings Connect cMT SVR with a router via RJ 45 Ethernet cable Launch Cloud EB Pro on PC or iPad find the cMT SVR and use the default password 111111 to log in and configure Browser IP 192 168 Ey Click the System Settings button and configure cMT SVR The interface can be used to download or upload a project files ee HMI server Q EasyBuilder Pro Software Settings pean Launch EasyBuilder Pro software select your project file press F7 shortcut key to open the download dialog box P Name gt RENEA Select Ethernet gt IP tab gt Enter your cMT SVR IP gt Click Download to download this project file to CMT SVR Please refer to EasyBuilder Pro User Manual for software operation details communication Connections COM2 RS 485 COM1 RS232 COM1 RS 232 12345 6789 1 Data 2 RxD Received Data 3 TxD Transmitted Data 4