1. of reading Influence of Frequency From 30 to 48 Hz lt 1 of R From 65 to 1000 Hz lt 0 5 of R From 1 kHz to 5 kHz lt 1 of R MECHANICAL SPECIFICATIONS Operating Temperature 14 to 122 F 10 to 50 C Storage Temperature 4 to 158 F 20 to 70 C Influence of Temperature lt 0 1 per 10 K Influence of Humidity From 10 to 90 0 1 Jaw Opening 2 25 57mm max Maximum Conductor Size 2 05 52mm Envelope Protection IP 40 IEC 529 Drop Test 1 m IEC 68 2 32 Mechanical Shock 100 g IEC 68 2 27 Vibration 5 to 15 Hz 0 15 mm IEC 68 2 6 15 to 25 Hz 1 mm 25 to 55 Hz 0 25 mm Polycarbonate Material Handles ABS Grey and Lexan 500R Red UL94V0 Jaws Lexan 500R Red UL94V0 Dimensions Quality AEMC Products Online at www alobalTestSupply com Weight 1 21 Ibs 550 g Output Two standard safety banana jacks 4mm SAFETY SPECIFICATIONS cE on Ws E192383 Electrical Double insulation or reinforced insulation between the primary or secondary and the outer case of the handle conforms to IEC 1010 2 032 Common Mode Voltage 600V Category III Pollution Degree 2 Dielectric Strength 5550V 50 60 Hz between primary secondary and the outer case of the handle Electromagnetic Compatibility EN 50081 1 Class B EN 50082 2 Electrostatic discharge IEC 1000 4 2 Radiated field IEC 1000 4 3 Fast transients IEC 1000 4 4 Magnetic field at 50 60 Hz IE
2. AC Current Probe Model SR600 User Manual DESCRIPTION The SR600 Cat 2113 42 is designed for use in industrial environments The ergonomic design allows it to easily attach to cables or small bus bars The circular jaws guarantee a very good accuracy and low phase shift The probe has a measurement range up to 1000 Arms continuous and is compatible with any AC ammeter multimeter or other current measurement instrument with an input impedance lower than 5Q To achieve the stated accuracy use the SR600 with an ammeter having an accuracy of 0 75 or better WARNING The safety warnings are provided to ensure the safety of personnel and proper operation of the instrument Read the instruction completely Use caution on any circuit potentially high voltages and currents may be present and may pose a shock hazard Do not use the probe if damaged Always connect the current probe to the measuring device before it is connected around the conductor Do not use on non insulated conductor with a potential to ground greater than 600V CAT Ill pollution 2 Use extreme caution when clamping around bare conductors or bus bars Before each use inspect the probe look for cracks in housing or output cable insulation Do not use clamp in wet environment or in locations that hazardous gases exist Do not use the probe anywhere beyond the tactile barrier INTERNATIONAL ELECTRICAL SYMBOLS Ol This symbol signifies that the current
3. C 1000 4 8 ORDERING INFORMATION AC Current Probe SR600 00 Cat 2113 42 Includes a user manual and a product warranty and registration card Accessories Set of two Leads 5 ft safety 1000V Cat 2111 29 Banana plug adapter to non recessed plug Cat 1017 45 sales GlobalTestSupply com OPERATION Please make sure that you have already read and fully understand the WARNING section on page 1 Making Measurements with the AC Current Probe Model SR600 A set of test leads is required to take a measurement using the SR600 Connect the black test lead to the black input jack of the SR600 and the other end of the test lead to the common Connect the red test lead to the red input jack of the SR600 and the other end of the test lead to the AC current input on your DMM or other current measuring instrument Select the appropriate current range 2A AC range Clamp the probe around the conductor to be tested with the arrow pointed toward the load If the reading is less than 200 mA select the lower range until you obtain the best resolution Read the value display on the DMM and multiply it by the probe ratio 1000 1 If reading 0 659A the current flowing through the probe is 0 659A x 1000 659A AC For best accuracy avoid if possible the proximity of other conductors which may create noise Tips for Making Precise Measurements When using a current probe with a meter it is important to select the r
4. ange that provides the best resolution Failure to do this may result in measurement errors Make sure that probe jaw mating surfaces are free of dust and contamination Contaminants cause air gaps between the jaws increasing the phase shift between primary and secondary It is very critical for power measurement MAINTENANCE Warning e For maintenance use only original replacement parts e To avoid electrical shock do not attempt to perform any servicing unless you are qualified to do so e To avoid electrical shock and or damage to the instrument do not get water or other foreign agents into the probe Cleaning To ensure optimum performance it is important to keep the probe jaw mating surfaces clean at all times Failure to do so may result in error in readings To clean the probe jaws use very fine sand paper fine 600 to avoid scratching the jaw then gently clean with a soft oiled cloth REPAIR AND CALIBRATION You must contact our Service Center for a Customer Service Authorization number CSA This will ensure that when your instrument arrives it will be tracked and processed promptly Please write the CSA on the outside of the shipping container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceable to N I S T includes calibration certificate plus recorded calibration data Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive e D
5. over NH 03820 USA Tel 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 repair aemc com Or contact your authorized distributor Costs for repair standard calibration and calibration traceable to N I S T are available NOTE All customers must obtain a CSA before returning any instrument TECHNICAL AND SALES ASSISTANCE If you are experiencing any technical problems or require any assistance with the proper use or application of this instrument please call our technical hotline 800 343 1391 508 698 2115 Fax 508 698 2118 Chauvin Arnoux Inc d b a AEMC Instruments techsupport aemc com www aemc com Quality AEMC Products Online at www G lobalTestSupply com sales GlobalTestSupply com ee 00 AN 100131 v6 04 11
6. probe is protected by double or reinforced insulation Use only factory specified replacement parts when servicing the instrument M This symbol signifies CAUTION and requests that the user refer to the user manual before using the instrument This is a type A current sensor This symbol signifies that application around and removal from HAZARDOUS LIVE conductors is permitted DEFINITION OF MEASUREMENT CATEGORIES CAT I For measurements on circuits not directly connected to the AC supply wall outlet such as protected secondaries signal level and limited energy circuits CAT Il For measurements performed on circuits directly connected to the electrical distribution system Examples are measurements on household appliances or portable tools CAT Ill For measurements performed in the building installation at the distribution level such as on hardwired equipment in fixed installation and circuit breakers CAT IV For measurements performed at the primary electrical supply lt 1000V such as on primary overcurrent protection devices ripple control units or meters RECEIVING YOUR SHIPMENT Upon receiving your shipment make sure that the contents are consistent with the packing list Notify your distributor of any missing items If the equipment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Quality AEMC Products Online at www GlobalTes
7. tSupply com sales GlobalTestSupply com J AEMC INSTRUMENTS 4 37 111 mm 3 98 101 mm 2 25 57 mm gt 1 22 31 mm A ww 912 0S 8 Tactical Barrier keep hands below this barrier 3 90 99 mm 1 71 43 5 mm ELECTRICAL SPECIFICATIONS Current Range 0 1 to 1000A AC continuous cycle lt 1 kHz Transformation Ratio 1000 1 Output Signal 1mA AC A AC 1 A AC at 1000A Accuracy and Phase Shift 1 38 35 mm 1 77 45 mm Primary current 200A 1000A 1200A Accuracy 15 0 5 0 5 Phase shift 0 75 0 5 0 5 Reference conditions 23 C 3 K 20 to 75 RH 48 to 65 Hz external magnetic field lt 40 A m no DC component no external current carrying conductor test sample centered Primary current 0 1 to 10A 10A 50A Accuracy lt 3 0 1A 3 1 5 Phase shift N A 3 1 5 Load impedance 5Q Overload 1200A for 40 mn on 20 mn off Accuracy Per IEC 185 Frequency Range 30 Hz to 5 kHz current derating above 1 kHz using the formula 1000A x 1 Quality AEMC Products Online at www G lobalTestSupply com sales GlobalTestSupply com Load Impedance 59 max Working Voltage 600V CAT III Common Mode Voltage 600V Cat III Influence of Adjacent Conductor lt 1mA A AC Influence of Conductor in Jaw Opening 0 1

Download Pdf Manuals

image

Related Search

Related Contents

LEDテールランプキット 取扱説明書  Page 1 Page 2 このたびは丶 スプリ ングビン刷会員 NX~SPTをお      Suivre à la trace l`activité de deux co-acteurs :  go electronic gohd400 product manual    19” / 22” LCD - wide User`s MANUAL  Eudora Email 6.1 New Features Manual for Windows  USER MANUAL - Door Entry Direct, Door entry systems, Intercoms  