1. 12 Troublesho ting 22 er aet aub E ete IMPORTANT SAFETY INSTRUCTIONS Read these safety instructions entirely Read and understand all safety instructions before operating machine Precaution in installation and operation Don t place the detector in an extreme hot or cold condition and avoid setting the machine close to the heating radiator tap air humidifier and stoves Don t place the detector near the window under the direct sunshine In case of inevitable the window curtain shield and hood should be used to shade the detector No contact of the machine is allowed with dust ammonium alcohol diluents and pulverized adhesive etc The detector should be installed on a leveled ground Never place it close to the air compressor or any substance that may generate vibration During the operation don t close to the detector unless the operator The dynamic balance detector should use separated power socket Don t connect any other wire in this socket Attention must be paid to the reliable grounding if there is no grounding connection in the socket it must be added before connect with the power source The wire line of dynamic balance detector should be prevented from stepping on A space of 50 cm width should be left between the wall and detector to ensure the ventilation for heat Spaces also should be left on the left and right sides of the machine for operator to operate the machine without obstacle
2. 6 Re calibrate it according to the User s Manual 7 Input the data of dis In I SFA again according to the marks on the machine then calibrate it again to check if the machine work normally
3. 2 Replace the power plate 3 Check the plug of the connecting line 4 Replace the computer plate The display is normal but the starting switch and the inputing knobs heads A L C is malfunction 1 The connection of the switch is not well 2 Dead computer The display is normal but the brake does not work 1 Loosen connection between computer plate and power plate 2 Power plate malfunction 3 Computer plate malfunction 1 Open the cover and tighten the lug of the touch switch 2 Start the machine again 1 Tighten the connecting line between the computer plate and the power plate 2 Replace the power plate 3 Replace the computer plate The starting is slow with failure in braking and imprecision in balance The operation is normal but the balance value is not accuracy Driving belt is too loose 1 The body of machine is placed unstably 2 Affected by the cone or quick bolt cap 3 The wheel is not mounted tightly 4 The power supply inside the machine is unstable 5 Power voltage fluctuate violently 6 The calibration value changed 7 The value inside the machine changed Adjust the position of the motor or change the driving belt 1 Get rid of the problem according to the testing result 2 Re tighten the quick bolt cap 3 Check the power supply 4 The operator can adjust the power supply by self 5 Replace the computer plate if necessary
4. Contact with the special service man for maintenance before you have to move the dynamic balance detector Call your attention to the following problems Eye dierum Sirait diank ee Reve EE The part of rotational shaft should be prevented from any strike The dynamic balance detector can be restarted only 5 seconds later after shut down On the top of dynamic balance detector never put many heavy substances Please refer the content of self calibration in case of abnormal operation Cut off the power supply and pull out the plug immediately if the noise smoke or any other accidents take place suddenly then inform the relevant service man In front of the power socket of the dynamic balance detector space must be left so that you can rapidly pull out the plug The dynamic balance detector can t be used beyond the scope of its functions stipulated in the manual 1 Technical Data M ees Max wheel weight 70kg Cycle time lt 10s Power supply 220V 110V 50 60HZ Working temperature 5 C 50 C Balancing function DYNAMIC STA ALU1 ALU2 ALU3 Balancing precision 1g Rim diameter 10 24 Rim width 1 5 20 Net weight 150kg 2 The balance weight plumb block used in t ine Betector 2 1Stacked package of balance weight plumb Ordinary steel rim section and aluminum alloy rim section 2 2Stuck balance weight plumb Aluminum alloy rim section Note The errors in balance weight plumb directly affect
5. 5g press down this knob to show the left unbalance value 5 Knob for automatically test the inputting value 6 Hm Knob for static balance and selecting the position amp mode of ALU balancing block T o Knob for emergency shut down Starting knob 5 Basic operation of balance detector and selection of functions 5 1 wheel balancer 5 1 1 Turn on the power switch on the left side of the detector indicator 9 displays CB2 10 show 00 and then the indicators 9 10 change to A 8 0 5 1 2 Mounting of tire Select the positioning cone that fits the central hole ofthe rim to install it at the center of rotational shaft then tighten and lock it with the handle nut The maximum weight of wheel should not more than 70kg 5 1 3 Input the value A Pull the distance gauge A to the position where the balance block is to be setted Press E knobs and input the reading on the gauge into indicator 10 meanwhile the indicator 9 should display the value as A 5 1 4 Input the value L Use the width gauge that taken from the accessories to measure the width between two sides of the rim press knobs to input the reading on the gauge into the indicator 10 meanwhile the indicator 9 should display the value as L 5 1 5 Input the value D After the value of Dia confirmed press 5 nobs to input the value into the indicator 10 meanwhile the indicator 9 should display the value as D 5 1 6 Press the starti
6. WHEEL BALANCER READ THIS ENTIRE MANUAL BEFORE OPERATION BEGINS RECORD HERE THE FOLLOWING INFORMATION WHICH IS LOCATED ON THE SERIAL NUMBER DATA PLATE Serial No Model No Manufacturing date INDEX Important safety instructions Precaution in installation and operation Call your attention to the following problems 1 Technie aldatar see 22 es et RBB 2 The balance weight plumb block used in the detector 3 Main components of CB series dynamic balance detector 4 Knobs and indicator Lamps on controlling panel 5 Basic operation of balance detector and selection of functions 5 1 wheel balancer 5 2 wheel balancer 6 Counter positioning Te Sel calibr ti n sententie eI Eon teem e eeu nee dne 8 Standard accessories of CB series tire dynamic balance detector 9 Optional accessories of CB series tire dynamic balance detector 8 10 Standard accessories List 9 11 Code in computer self diagnosis of CB series balance detector
7. any point of external side of the rim 4 Press this knob the wheel will rotate the indicators 9 and 10 show End CAL the calibration is complete 8 Standard accessories of CB Series Tire Dynamic Balance Detector 8 8 m Positioning cones for axis Thread rod eiie Plumb100g Quick bolt cap Calipers Counterweight nip Spring Plastic cup 9 Optional accessories of CB Series Tire Dynamic Balance Detector Protection cover Extra large cone flange 10 Standard accessories List Counterweight nip Caliper Positioning cone for axis Quick bolt cap Thread rod Plumb 100g Plastic cup Spring Piece Piece 3Pieces Piece Piece Piece Piece Piece 11 Code in Computer Self diagnosis of CB Series Balance Detector 12 Trouble shooting Symptom No display on the screen after starting Too big unbalance try other wheel Nonsense Trouble in phase generator or power plate replace it Rotation speed is too low or wheel hasn t been mounted with tire Errors in power system rotational direction is not right Memory damaged or signal lost calibrate again or renovate The procedure of calibration is not appropriate or computer plate or sensor damaged Cause Solution 1 External power malfunction 2 Power plate malfunction 3 Loosen connection between computer plate and power plate 4 Computer plate malfunction 1 Check the external power supply
8. ater after starting the detector will automatically stop Pull down the protection hood the detector of B type will automatically start up 5 2 7 Display the value of unbalance The value displayed by indicators 9 and 10 is the value of unbalance Rotate the wheel by hand the positioning lamps 11 and 12 will constantly flash 6 ru ULL 5 2 8Right till all lamps in a set of 11 or 12 start to light that means the highest point of rim is the unbalance point Among which the indicator 11 represents the value of internal side of the rim and the 12 represents the value of external side of the rim 5 2 9 At the unbalance point of the rim mount a balance block corresponding to the measured value The indicator 9 represents internal side of the rim while the indicator 10 represents the external side of the rim 5 2 10 Repeat the procedures 6 10 untill the indicators 9 and 10 show 00 5 2 11Dismount the tire from the rotational shaft the balance detection is now finished Selection of functio ie This lamp lighting shows that it is adapt to the tires that used for motorcycles or those wheels on both sides of which placing the balance block is not allowed This lamp lighting shows that it is adapt to the alloy rim at the shoulder of which the balance block can be stuck on This lamp lighting shows that it adapts to the alloy rim on the hidden external side of which the balance block can be stuck on i
9. e This lamp lighting shows that on the external side of which the balance block L can be stuck on and on the internal side of the rim the balance block can be braced or inserted When the four sets of the lamps all went out it shows a state of standard balance Whenever you start the detector the computer will automatically set at such state 6 Counter positioni mee Ree ng CRM EN Counter positioning method is a widely used method It is applicable to common steel rims and aluminum alloy rims Especially for the new rims and it can provide high balance precision Procedures of counter positioning Place the spring with the Place a bottom toward the balancer suitable cone Place the Plastic cup Quick bolt wheel cap 7 Self calibration When there is doubt in the precision of the measured value this function can be used Don t shut down the detector during the operation because it may cause the inputting of the wrong value Don t arbitrarily use this function Procedures in operation 1 Mount the balanced tire 2 Press downthe R knob after about half a second press the starting knob The indicators 9 and 10 show CAL CAL the positioning lamp of unbalance will flash several seconds and then went out automatically 3 Press down the starting knob after several seconds the detector automatically stop the indicators 9 and 10 show Add 100 Add a balance block of 100g at
10. is lamp lighting shows that on the external side of which the balance block can be stuck on and at the internal side of the rim the balance block can be braced or inserted When the four sets of indicators all went out it shows the standard balance When ever you start the detector the computer automatically set at such state WHEEL BALANCER N Z 5 2 1 Turn on the power switch on the front panel The indicator 9 displays 850 and then indicators 9 10 change into A 8 0 5 2 2 Mounting of tire Select the positioning cone that fits the central hole of the rim to install it at the center of rotational shaft then tighten and lock it with the handle nut The maximum weight of wheel should not more than 70kg 5 2 3 Input the value A Pull the distance gauge A to the position where the balance block is to be setted Press knobs and input the reading on the gauge into indicator 10 meanwhile the indicator 9 should display the value as A 5 2 4 Input the value L Use the width gauge that taken from the accessories to measure the width between the two sides of the rim press knobs to input the measured width into indicator 10 meanwhile indicator 9 should display the value as L 5 2 5 Input value D After the value of rim Dia confirmed press knobs to input the value into the indicator 10 meanwhile the indicator 9 should display the value as D 5 2 6 Press the starting knob to start the operation 7 seconds l
11. ng knob to start the operation several seconds later the detector wil automatically stop Pull down the protection hood the detector of B type will automatically start up 5 1 7 Display the unbalance value The value displayed by indicators 9 and 10 is the value of unbalance rotate the wheel by hand the positioning lamps 11 12 will constantly flash 5 1 8 Right till all lamps in a set of 11 or 12 start to light it means that the position of rim s highest point is the unbalance point Among which the 11 represents the value of internal rim side and the 12 represents the value of external rim side 5 1 9 At the unbalance point of the rim mount a balance block corresponding to the measured value the indicator 9 represents internal side of the rim while the indicator 10 represents the external side of the rim 5 1 10 Repeat the procedure 6 10 till the indicators 9 and 10 show 00 5 1 11 Dismount the tire from the rotational shaft the balance detection is now finished Selection of functions 5 2 7 This lamp lighting shows that it is adapt to the tires used for motorcycle or those wheels at both sides of which placing the balance block is not allowed This lamp lighting shows that it is adapt to the alloy rim at the shoulder of which the balance block can be stuck on This lamp lighting shows that it is adapt to the alloy rim on the external hidden side of which the balance block can be stuck on Th
12. the tested result of the detector 3 Main Mii E a nn series id M valance detector Side cover plate Side view Front view A Distance gauge Side cover plate Side view 4 Knobs and indicator Lamps on Controlling Panel O IL 12 0 QD S ub 13 TD 8 B Distance setting knob Press down E to adjust the setted distance value on indicator 2 TN Width setting knob Press down B to adjust the setted width value on indicator 3 D Dia setting knob Press down to adjust the setted Dia value on indicator 4 High precision balance knob Indicator displavs 00 when unbalance lt 5g press down this knob to show the left unbalance value 5 D Knob for automatically test the inputting value 6 Knob for static balance and selecting the position amp mode of ALU balancing block T Knob for emergency shut down 8 Starting knob 9 10 i Value display indicator 11 12 Positioning lamp for unbalance point 13 Balancing block mode indicating lamp D 9 9 p 42 10 13 8 dis qa Distance setting knob Press down to adjust the setted distance value on indicator 2 Width setting knob Press down to adjust the setted width value on indicator 3 arp Dia setting knob Press down to adjust the setted Dia value on indicator TIRE 4 lt 5g High precision balance knob Indicator displays 00 when unbalance lt