Home
        Q62DA-FG Channel Isolated Digital
         Contents
1.     Nanterre Cedex  France M I D C BHOSARI PUNE 411026  India  TEL   33 1 5568 5568 Tel    91 20 712 2807   South Africa Circuit Breaker Industries LTD  Australia Mitsubishi Electric Australia Pty  Ltd   Tripswitch Drive  Elandsfontein Gauteng  348 Victoria Road  PostalBag  No 2   South Africa Rydalmere  N S W 2116  Australia  Tel    27 11 928 2000 Tel    61 2 9684 7777     MITSUBISHI ELECTRIC CORPORATION    HEAD OFFICE   1 8 12  OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212  JAPAN  NAGOYA WORKS   1 14  YADA MINAMI 5 CHOME  HIGASHI KU  NAGOYA  JAPAN       Specifications subject to change without notice   Printed in Japan on recycled paper     
2.    If the screws are tightened too much  it may cause damage to the screw and or the module   resulting in fallout  short circuits or malfunction   Be sure to shut off all phases of the external power supply used by the system before mounting or  removing the module   Not doing so may cause damage to the module   Do not directly touch the conductive area or electronic components of the module   Doing so may cause malfunction or failure in the module        Always ground the FG terminal for the PLC  There is a risk of electric shock or malfunction   When turning on the power and operating the module after wiring is completed  always attach the  terminal cover that comes with the product    There is a risk of electric shock if the terminal cover is not attached    Use applicable solderless terminals and tighten them with the specified torque  If any solderless   m terminal is used  it may be disconnected when the terminal screw comes loose  resulting in  ailure    Tighten the terminal screws within the range of specified torque    If the terminal screws are loose  it may result in short circuits or malfunction    If the terminal screws are tightened too much  it may cause damage to the screw and or the  module  resulting in short circuits or malfunction    Be careful not to let foreign matters such as sawdust or wire chips get inside the module    These may cause fires  failure or malfunction    The top surface of the module is covered with protective film to prevent foreign ob
3.   86 21 6120 0808    Tel    55 11 5908 8331 Taiwan Setsuyo Enterprise Co   Ltd   Germany Mitsubishi Electric Europe B V  German 6F   No 105 Wu Kung 3rd RD  Wu Ku  Branch Hsiang  Taipei Hsine  Taiwan  Gothaer Strasse 8 D 40880 Ratingen  Tel    886 2 2299 2499  GERMANY Korea HAN NEUNG TECHNO CO  LTD   Tel    49 2102 486 0 1F Dong Seo Game Channel Bldg    U K Mitsubishi Electric Europe B V  UK 660 11  Deungchon dong Kangsec ku   Branch Seoul  Korea    Travellers Lane  Hatfield  Herts   AL10 Tel    82 2 3660 9552  8XB UK Singapore Mitsubishi Electric Asia Pte  Ltd   Tel    44 1707 276100 307 Alexandra Road  05 01 02     Italy Mitsubishi Electric Europe B V  Italian Mitsubishi Electric Building  Branch Singapore 159943  Centro Dir  Colleoni  Pal  Perseo Ingr 2   Tel   ea aa  Via Paracelso 12  20041 Agrate B   Thailand F  A  Tech Co  Ltd     Milano  Italy 898 28 29 30 S V City Building  Office    Tel    39 039 6053344 Tower 2 Floor 17 18 Rama 3 Road     Spain Mitsubishi Electric Europe B V  Spanish Bangkpongpang  Yannawa   Branch Bangkok 10120  Carretera de Rubi 76 80 Tel    66 2 682 6522  08190 Sant Cugat del Valles  Indonesia P T  Autoteknindo SUMBER MAKMUR  Barcelona  Spain Jl  Muara Karang Selatan Block a Utara  Tel    34 93 565 3131 No 1 Kav  No 11 Kawasan Industri   France Mitsubishi Electric Europe B V  French Pergudangan Jakarta   Utara 14440  Branch Tel    62 21 663 0833    India Messung Systems Put Ltd   25 Boulevard des Bouvets  F 02741 Electronic Sadan NO 111 Unit No15 
4.  shielded wire for the power wire        5 3 Switch setting for intelligent functional module    The settings for the intelligent function module are performed using the I O allocation  settings for the GX Developer  It can be easy to set by inputting using hexadecimal 4  digits        me AA R  HOO         es    Switch 2 Not used    Switch 3 HOLD CLEAR function setting  OH   CLEAR  1 to FH  numeric value other than 0H    HOLD    Switch 4    A 001  Fixed    OH   Normal mode  D A conversion processing   1 to FH   numeric  value other than OH    Offset gain setting mode       Switch 5      Setting any value within the setting range will provide the same operation     When the setting range is 1 to FH  set 1 for example     6  External Dimensions    nn                                                                                                                                     98 3 86                                                                                                                                                                                                                          90 3 54  22 0 87  27 4 1 08   UNIT   mm  in       UNIT  mm in                         Warranty    Mitsubishi Electric shall not be liable for any loss caused by reasons for which Mitsubishi is not held  accountable  lost business opportunities or unrealized gain on the customer s side resulting from failure of the  product  or any other damage  secondary disaster  accident  damage 
5. MITSUBISHI  Q62DA FG    Channel Isolated Digital Analog Converter Module    Thank you for buying the Mitsubishi general purpose programmable logic  controller MELSEC Q Series        Prior to use  please read both this manual and detailed manual thoroughly       and familiarize yourself with the product   User s Manual   Hardware     Cc   MELSEC Q MODEL Q D A FG U HW  i ichi MODEL   Mitsubishi Programmable 13JT91    Logic Controller IB 0800277 C  0706  MEE    2002 MITSUBISHI ELECTRIC CORPORATION      SAFETY PRECAUTIONS       Read these precautions before using      When using Mitsubishi equipment  thoroughly read this manual and the associated  manuals introduced in the manual  Also pay careful attention to safety and handle the  module properly    These precautions apply only to Mitsubishi equipment  Refer to the user s manual of the  CPU module to use for a description of the PLC system safety precautions    These   SAFETY PRECAUTIONS  classify the safety precautions into two categories    DANGER  and  CAUTION      Procedures which may lead to a dangerous condition and      lt DDANGER cause death or serious injury if not carried out properly  I  I   I    Procedures which may lead to a dangerous condition and  Z CAUTION cause superficial to medium injury  or physical damage only  if  not carried out properly  i    Depending on circumstances  procedures indicated by  NCAUTION may also be linked  to serious results    In any case  it is important to follow the directions for us
6. age    Store this manual in a safe place so that you can take it out and read it whenever  necessary  Always forward it to the end user         DESIGN PRECAUTIONS      NCAUTION    e Do not bunch the control wires or communication cables with the main circuit or power wires   or install them close to each other   They should be installed 100 mm  3 94 inch  or more from each other     Not doing so could result in noise that may cause malfunction    e At power ON OFF  voltage or current may instantaneously be output from the output terminal  of this module  In such case  wait until the analog output becomes stable to start controlling  the external device      INSTALLATION PRECAUTIONS        CAUTION    e Use the PLC in an environment that meets the general specifications given in the User s Manual  of the CPU module being used   Using this PLC in an environment outside the range of the general specifications may cause  electric shock  fire  malfunction  and damage to or deterioration of the product   While pressing the installation lever located at the bottom of module  insert the module fixing tab into  the fixing hole in the base unit until it stops    Improper installation may result in malfunction   breakdown or the module coming loose and  dropping  Securely fix the module with screws if it is subject to vibration during use   Tighten the screws within the range of specified torque   If the screws are loose  it may cause the module to fallout  short circuits  or malfunction
7. et gain setting at ambient temperature   Q62DA FG needs to be powered on 30 minutes prior to operation for compliance to the specification    accuracy     2  Accuracy per temperature change of 1   C   Example  Accuracy when temperature changes from 25 to 30   C   0 1   Reference accuracy    0 008     C  temperature coefficient   x 5   C  temperature change difference    0 14     3  The following indicates the external load resistance when output current is 20mA or more     External supply power    22mA    Output 20mA  current    500 600  External load resistance    3  Part Names    This section explains the names of the components for the Q62DA FG     l CH1 COM1       Po Vacant  pS Vacant  po Vacant       AN    AAAS    TA    N    TA    11    IME    Ne    T   e Slelelel   sle s e  ef Jefe  ehi     V        LET EEE    ZA              Number    Name   Description           o                   1  RUN LED Displays the operating status of the Q62DA FG     Normal operation  i   During offset gain setting mode    5V power supply interrupted  watch dog timer  error  5V power switched off  watchdog timer error  occurred  or online module change enabled       During warning output occurrence    2  ERR  LED    Error  i   Error in switch settings  Switch No  5 of the intelligent function module has been  set to a value other than zero  0      Normal operation  3  ALM LED    During disconnection detection    Normal operation    Off  External power supply  This is the terminal for connectin
8. g the 24 V DC external power supply   terminal    4  Handling Precautions     1  Do not drop the module or cause it to receive strong impact      2  Tighten the terminal screws for the module to the specified torque shown below   Insufficient tightening torque could result in shorts  failures or malfunction     Screw location Tightening torque  M3 screw   Module mounting screw  M3 screw  0 36 to 0 48N m       Terminal block terminal screw  M3 screw  0 42 to 0 58 N m  Terminal block mounting screw  M3 5 screw  0 66 to 0 89 N m       5  Wiring  5 1 Wiring precautions     1  Use separate cables for the AC control circuit and the external input signals of  the Q62DA FG to avoid the influence of the AC side surges and inductions      2  Ground one point of the shield for shielded wires or shielded cables     5 2 External wiring        1  For voltage output                                                                                                                                                                                                                                                                    1  DS Control valve etc   D A yr 1kQ  conversion to  pe       GND 1MQ  o AD Amplifier  conversion  DC24V    24V        4 4  DC DC La I   Filter 24G     Sa LY EG mi   2  For current output    4    Control valve etc   ue Dis 02  DA a COM  conversion it to      GND 60082    AD  Amplifier  conversion  DC24V    24V          p m FG m                        1 Use a twisted two core
9. jects such as  cable offcuts from entering the module when wiring    Do not remove this film until the wiring is complete    Before operating the system  be sure to remove the film to provide adequate heat ventilation     About This Manual  The following manuals are also related to this product  Order them if necessary     Related Manual    Manual No   Model code   Channel Isolated Digital Analog Converter Module User s Manual SH 080281E 13JR52     Conformance to the EMC Directive Low Voltage Directive  When incorporating the Mitsubishi PLC into other machinery or equipment and keeping  compliance with the EMC and low voltage directives  refer to Chapter 3   EMC Directives and  Low ieee Directives  of the User s Manual  Hardware  included with the CPU module or base  unit used     The CE logo is printed on the rating plate on the main body of the PLC that conforms to the EMC  directive and low voltage instruction    By making this product conform to the EMC directive and low voltage instruction  it is not  necessary to make those steps individually           1  Overview    This manual explains specifications and the names of the components for the  type Q62DA FG channel isolated digital analog converter module  hereafter  Q62DA FG  which are used in combination with the MELSEC Q Series CPU  module     2  Specifications    The specifications for the Q62DA FG are shown in the following table  For  general specifications  refer to the operation manual for the CPU module being  u
10. sed               o    Number of analog outputs 2 points  2 channels   Digital input 16 bit signed binary   12288 to 12287   16384 to 16383     Voltage  12 to 12VDC  External load resistance  1k to 1M Q   Analog output Current 0 to 20mADC  External load resistance  0 to 600 Q   0 to 22mADC  Please refer to Note 3   Analog output range Digital input value  0 to 5V 0 416mV  Tto 5V te 0 333mV  Voltage  10 to 10V  16000 to 16000 0 625mV  User range setting 2   _ 0 366mV  User range setting 3 1200A a TED 0 183mV  0 to 20mA 1 66 nA  Current  4 to 20mA one ere 1 33 pA  User range setting 1    12000 to 12000 0 671 uA    I  O characteristics  maximum resolution     Accuracy relative   accuracy      to maximum  analog output    Within   0 1   Voltage    10mV  Current    20 A     Temperature  coefficient      10ms 2 channels  Absolute Voltage  13V  maximum output 23mA    12bit    Reference   TE  U   160ppm    C  0 016     C    it ah number of writes for 100 000    Available   en Isolation Dielectric Insulation  and PLC power supply __ isolation  channels isolation cycles    levation 2000   Between extemal supply  7 5 former  elevation m   more  power and analog output isolation   cannel      80ppm    C  0 008     C     Isolation specifications    Q62DA FG    16 points   18 points terminal block   0 3 to 0 75mm    R 1 25 3  Solderless terminals with sleeves are not applicable   24VDC   20    15     0 3A  Internal current consumption   5 VDC  0 37A    Weight 0 20kg     1  Accuracy of offs
11. to equipment other than the product or  disruption of other business operations arising out of special circumstances which may or may not have been  predicted at Mitsubishi     AN For safe use of the product    e This product is manufactured as a general purpose product intended for general industrial use only  It is not  designed nor manufactured for use in an equipment or system affecting human lives    e If you are considering to use this product in equipment or systems for nuclear power generation  power  generation  aerospace  medical or passenger transport applications  consult our sales representatives    e This product is manufactured under our strict quality control system  However  if the product is used in the  intended facility in such a way that a failure of the product may lead to serious accident or loss  incorporate  backup or fail safe functions into the system design        Country Region Sales office Tel Country Region Sales office Tel    U S A Mitsubishi Electric Automation Inc  Hong Kong Ryoden Automation Ltd   500 Corporate Woods Parkway Vernon 10th Floor  Manulife Tower  169 Electric  Hills  IL 60061 Road  North Point  HongKong  Tel    1 847 478 2100 Tel    852 2887 8870   Brazil MELCO TEC Rep  Com e Assessoria China Ryoden Automation Shanghai Ltd     Tecnica Ltda  3F Block5 Building Automation   Rua Correia Dias  184  Instrumentation Plaza 103 Cao Bao Rd   Edificio Paraiso Trade Center 8 andar Shanghai 200233 China   Paraiso  Sao Paulo  SP Brazil Tel  
    