1. The following view applies to EKI 5525S ST EKI 5525SI ST EKI 5525M ST and EKI 5525MI ST Table 1 8 Front View LOVDINT e Ot Figure 1 5 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 2 ETH port Four RJ45 ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 3 LNK ACT LED Link activity LED 12 PRODUCT OVERVIEW Table 1 8 Front View Continued No Item Description 4 Speed LED Fast Ethernet e Amber 100M e Off 10M 5 ST port EKI 5525S ST EKI 5525SI ST One ST single mode port EKI 5525M ST EKI 5525MI ST One ST multi mode port The following view applies to EKI 5524SS EKI 5524SSI EKI 5524MM and EKI 5524MMI 19VDINT OT lvan e Figure 1 6 Front View Table 1 9 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 2 ETH port Four RJ45 ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 3 LNK ACT LED Link activity LED 13 PRODUCT OVERVIEW Table 1 9 Front View Continued No Item Description 4 Speed LED Fast Ethernet e Amber 100M e Off 10M 5 ST port EKI 5524SS EKI 5524SSI Two SC single mode po
2. Tuesday October 28 2014 9 38 43 AM M Figure 3 7 View Settings Main Form Setting Table 3 2 Utility Settings Main Form Setting Main Window Settings Maximum Main Window Check the box to enable the limiting of main windows on load to the On Load maximum value Log Settings Show Log Message Check the checkbox to show the log message Window Save Log to File Check the checkbox to save log to file Browse Click Browse to choose a file to save Language Settings Interface Language Click the drop down menu to select an interface language Traditional Chinese Simplified Chinese or English 54 CONFIGURATION UTILITY Table 3 2 Utility Settings Main Form Setting Continued Item Description OK Click OK to save and exit the utility setting Cancel Click Cancel to discard the changes Apply Click Apply to save the utility setting Management Tools Help Utility Settings a Main Form Setting Device Manager Tree View Grouping By Type si Show Empty Device Type Node Expand New Appended Device Node Device Auto Detection After utility ready start auto detection after JO 1 for disable auto detection second Auto detect devices every 30 second Check device alive every 10 second Mark device as
3. 4 EKI 5725 t 4 EKI 5725 3 Device Server HT Serial Ports TES 3 6 4 5 Tuesday October 28 2014 9 58 32 AM Tl Figure 3 6 Configuration Utility Overview Table 3 1 Configuration Utility Overview No Item Description 1 Menu Bar Displays File View Management Tools and Help 2 Tool Bar Useful management functions shortcuts 3 Tree View All devices will be searched and listed in this area You can arrange different favorite group and virtual COM ports 4 Information Panel Click on the devices or move cursor to the devices the related information is shown in this area 5 Status Bar Displays the current time 6 Configuration Area Click on the items on the TreeView Area the configuration page displays in this area 53 CONFIGURATION UTILITY 3 5 Menu Bar 3 5 1 View Menu Utility Settings Click View Settings to configure utility settings e Advantech EKI Device Configuration Utility v1 71 File View Management Tools Help GP ER Utility settings Main Window Settings Device Manager V Maximum Main Window On Load Log Settings Show Log Message Window Save Log to File c program files x86 eki device configuration utility cdconfiguratior Language Setting Interface Language English v Language setting will take effect after restart Cancel Apply
4. Figure 1 13 Front View Table 1 16 Front View No Item Description 1 ETH port Two 10 100 1000BaseT X ports 2 ETH port Four 10 100BaseT X with PoE ports 3 LNK ACT LED Link activity LED 4 Speed LED Fast Ethernet e Amber 100M e Off 10M 5 System LED panel See System LED Panel only for EKI 5725FP EKI 5725F PI EKI 5624P EKI 5624PI and EKI 5729P EKI 5729PI on page 23 for fur ther details 20 PRODUCT OVERVIEW The following view applies to EKI 5729P and EKI 5729PI 1 MA1 5 2 ki 4 mi Figure 1 14 Front View Table 1 17 Front View No Item Description 1 ETH port Two 10 100 1000BaseT X ports 2 ETH port Eight 10 100 1000BaseT X with PoE ports 3 LNK ACT LED Link activity LED 4 Speed LED Gigabit Ethernet e Green 1000M e Amber 100M e Off 10M 5 System LED panel See System LED Panel only for EKI 5725FP EKI 5725FPI EKI 5624P EKI 5624PI and EKI 5729P EKI 5729PI on page 23 for fur ther details 21 PRODUCT OVERVIEW System LED Panel Figure 1 15 System LED Panel Table 1 18 System LED Panel No LED Name LED Color Description 1 PW1 LED Solid green Powered up Off Powered down or not installed 2 PW2 LED Solid green Powered up Off Powered down or not installed 3 P Fail Solid red When PW1 or PW2 is disconnected the LED lights Off When
5. PRODUCT OVERVIEW The following view applies to EKI 5726F and EKI 5726FI Figure 1 11 Front View Table 1 14 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 2 ETH port Sixteen 10 100 1000BaseT X ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality LNK ACT LED Link activity LED 4 SpeedLED Gigabit Ethernet e Green 1000M e Amber 100M e Off 10M 5 ETH port Two 100 1000Base FX SFP ports 18 PRODUCT OVERVIEW The following view applies to EKI 5725FP and EKI 5725FPI Table 1 15 Front View h Figure 1 12 Front View No Item Description 1 ETH port Four 10 100 1000BaseT X with PoE ports 2 LNK ACT LED Link activity LED 3 Speed LED Gigabit Ethernet e Green 1000M e Amber 100M e Off 10M 4 ETH port One 100 1000Base FX SFP port 5 System LED panel See System LED Panel only for EKI 5725FP EKI 5725FPI EKI 5624P EKI 5624PI and EKI 5729P EKI 5729PI on page 23 for fur ther details 19 PRODUCT OVERVIEW The following view applies to EKI 5624P and EKI 5624PI 1 mm 9 2 Hi a
6. Port 28 PoE 1 word 16 bits HEX 0x185B 36236 Power Port 29 PoE 1 word 16 bits HEX 0x185C 36237 Power 86 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 30 PoE 1 word 16 bits HEX 0x185D 36238 Power Port 31 PoE 1 word 16 bits HEX 0x185E 36239 Power Port 32 PoE 1 word 16 bits HEX 0x185F 36240 Power PoE Tem 1 word 16 bits HEX 0x1860 36241 perature 0x187F 36272 2 PoE Temperature C Ex poe temperature 32 Received MODBUS response 0x0020 Port 1 PoE 1 word 16 bits HEX 0x1860 36241 Temperature Port 2 PoE 1 word 16 bits HEX 0x1861 36242 Temperature Port 3 PoE 1 word 16 bits HEX 0x1862 36243 Temperature Port 4 PoE 1 word 16 bits HEX 0x1863 36244 Temperature Port 5 PoE 1 word 16 bits HEX 0x1864 36245 Temperature Port 6 PoE 1 word 16 bits HEX 0x1865 36246 Temperature Port 7 PoE 1 word 16 bits HEX 0x1866 36247 Temperature Port 8 PoE 1 word 16 bits HEX 0x1867 36248 Temperature Port 9 PoE 1 word 16 bits HEX 0x1868 36249 Temperature Port 10 PoE 1 word 16 bits HEX 0x1869 36250 Temperature Port 11 PoE 1 word 16 bits HEX 0x186A 36251 Temperature Port 12 PoE 1 word 16 bits HEX 0x186B 36252 Temperature Port 13 PoE 1 word 16 bits HEX 0x186C 36253 Temperature Port 14 PoE
7. 7 Insert the fiber cable into the transceiver The connector snaps into place and locks Figure 2 8 Attaching a Fiber Optic Cable to a Transceiver 8 Repeat the previous procedures to install any additional SFP transceivers in the switch The fiber port is now setup 2 4 2 Removing SFP Modules To disconnect an LC connector use the following guidelines 1 Press down and hold the locking clips on the upper side of the optic cable 2 Pull the optic cable out to release it from the transceiver s Figure 2 9 Removing a Fiber Optic Cable to a Transceiver 41 SWITCH INSTALLATION 3 Hold the handle on the transceiver and pull the transceiver out of the slot Handle Figure 2 10 Removing an SFP Transceiver Replace the dust plug on the slot if you are not installing a transceiver The dust plug protects hardware from dust contamination 2 5 Connecting the Switch to Ethernet Ports 2 5 1 RJ45 Ethernet Cable Wiring For RJ45 connectors data quality twisted pair cabling rated CAT5 or better is recom mended The connector bodies on the RJ45 Ethernet ports are metallic and connected to the GND terminal For best performance use shielded cabling Shielded cabling may be used to provide further protection Table 2 1 RJ45 Ethernet Wiring for Reference Straight thru Cable Wiring Cross over Cable Wiring Pin 1 Pin 1 Pin 1 Pin 3 Pin 2 Pin 2 Pin 2 Pin 6 Pin 3 Pin 3 Pin 3 Pin 1 Pin
8. Port 2 Link 1 word 16 bits HEX 0x1701 35890 Up Counter Port 3 Link 1 word 16 bits HEX 0x1702 35891 Up Counter Port 4 Link 1 word 16 bits HEX 0x1703 35892 Up Counter Port 5 Link 1 word 16 bits HEX 0x1704 35893 Up Counter Port 6 Link 1 word 16 bits HEX 0x1705 35894 Up Counter Port 7 Link 1 word 16 bits HEX 0x1706 35895 Up Counter Port 8 Link 1 word 16 bits HEX 0x1 707 35896 Up Counter Port 9 Link 1 word 16 bits HEX 0x1708 35897 Up Counter Port 10 Link 1 word 16 bits HEX 0x1709 35898 Up Counter Port 11 Link 1 word 16 bits HEX 0x170A 35899 Up Counter 80 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 12 Link 1 word 16 bits HEX 0x170B 35900 Up Counter Port 13 Link 1 word 16 bits HEX 0x170C 35901 Up Counter Port 14 Link 1 word 16 bits HEX 0x170D 35902 Up Counter Port 15 Link 1 word 16 bits HEX 0x170E 35903 Up Counter Port 16 Link 1 word 16 bits HEX 0x170F 35904 Up Counter Port 17 Link 1 word 16 bits HEX 0x1710 35905 Up Counter Port 18 Link 1 word 16 bits HEX 0x1711 35906 Up Counter Port 19 Link 1 word 16 bits HEX 0x1712 35907 Up Counter Port 20 Link 1 word 16 bits HEX 0x1713 35908 Up Counter Port 21 Link 1 word 16 bits HEX 0x1714 35909 Up Counter Port 22
9. Power Port 6 PoE 1 word 16 bits HEX 0x1845 36214 Power Port 7 PoE 1 word 16 bits HEX 0x1846 36215 Power Port 8 PoE 1 word 16 bits HEX 0x1847 36216 Power Port 9 PoE 1 word 16 bits HEX 0x1848 36217 Power 85 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3X tion Hex Port Info Port 10 POE 1 word 16 bits HEX 0x1849 36218 Power Port 11 PoE 1 word 16 bits HEX 0x184A 36219 Power Port 12 PoE 1 word 16 bits HEX 0x184B 36220 Power Port 13 PoE 1 word 16 bits HEX 0x184C 36221 Power Port 14 PoE 1 word 16 bits HEX 0x184D 36222 Power Port 15 PoE 1 word 16 bits HEX 0x184E 36223 Power Port 16 PoE 1 word 16 bits HEX 0x184F 36224 Power Port 17 PoE 1 word 16 bits HEX 0x1850 36225 Power Port 18 PoE 1 word 16 bits HEX 0x1851 36226 Power Port 19 PoE 1 word 16 bits HEX 0x1852 36227 Power Port 20 PoE 1 word 16 bits HEX 0x1853 36228 Power Port 21 PoE 1 word 16 bits HEX 0x1854 36229 Power Port 22 PoE 1 word 16 bits HEX 0x1855 36230 Power Port 23 PoE 1 word 16 bits HEX 0x1856 36231 Power Port 24 PoE 1 word 16 bits HEX 0x1857 36232 Power Port 25 PoE 1 word 16 bits HEX 0x1858 36233 Power Port 26 PoE 1 word 16 bits HEX 0x1859 36234 Power Port 27 PoE 1 word 16 bits HEX 0x185A 36235 Power
10. for technical support if you need additional assistance Please have the following infor mation ready before you call e Product name and serial number e Description of your peripheral attachment e Description of your software operating system version application software etc e Acomplete description of the problem e The exact wording of any error messages Regional Service amp Customization Centers China Kunshan 86 512 5777 5666 Taiwan Taipei Worldwide Offices Greater China China Toll Free 800 810 0345 Beijing 86 10 6298 4346 Shanghai 86 21 3632 1616 Shenzhen 86 755 8212 4222 Chengdu 86 28 8545 0198 Hong Kong 852 2720 5118 Taiwan Toll Free 0800 777 111 Neihu 886 2 2792 7818 Xindian 886 2 2218 4567 Taichung 886 4 2378 6250 Kaohsiung 886 7 229 3600 886 2 2792 7818 Netherlands Eindhoven 31 40 267 7000 Asia Pacific Japan Toll Free Tokyo Osaka Korea Toll Free Seoul Singapore Singapore Malaysia Toll Free Kuala Lumpur Penang Indonesia Jakarta Thailand Bangkok India Toll Free Pune Bangalore Australia Toll Free Melbourne Sydney About This Manual This user manual is intended to guide professional installers in installing and configuring the ProView Series Ethernet Switches It includes technical specifications software utility intro duciton as we as procedures for the use of the software utility to self manage the devices vii 0800 500 1055 8
11. 0x0001 10M Full 0x0002 100M Half 0x0003 100M Full 0x0004 1000M Half 0x0005 1000M Full OxFFFF No port Port 1 Speed 1 word 16 bits HEX 0x1100 34353 Port 2 Speed 1 word 16 bits HEX 0x1101 34354 Port 3 Speed 1 word 16 bits HEX 0x1102 34355 Port 4 Speed 1 word 16 bits HEX 0x1103 34356 Port 5 Speed 1 word 16 bits HEX 0x1104 34357 Port 6 Speed 1 word 16 bits HEX 0x1105 34358 Port 7 Speed 1 word 16 bits HEX 0x1106 34359 Port 8 Speed 1 word 16 bits HEX 0x1107 34360 Port 9 Speed 1 word 16 bits HEX 0x1108 34361 Port 10 1 word 16 bits HEX 0x1109 34362 Speed Port 11 1 word 16 bits HEX 0x110A 34363 Speed Port 12 1 word 16 bits HEX 0x110B 34364 Speed Port 13 1 word 16 bits HEX 0x110C 34365 Speed Port 14 1 word 16 bits HEX 0x110D 34366 Speed Port 15 1 word 16 bits HEX 0x110E 34367 Speed Port 16 1 word 16 bits HEX 0x110F 34368 Speed Port 17 1 word 16 bits HEX 0x1110 34369 Speed Port 18 1 word 16 bits HEX Ox1111 34370 Speed Port 19 1 word 16 bits HEX 0x1112 34371 Speed 75 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3X tion Hex Port Info Port 20 1 word 16 bits HEX 0x1113 34372 Speed Port 21 1 word 16 bits HEX 0x1114 34373 Speed Port 22 1 word 16 bits HEX 0x1115 34374 Speed Port 23 1 word 16 bits HEX 0x1116 34375 Speed Port 24 1 word 16 bits HEX 0
12. 1 word 16 bits HEX 0x186D 36254 Temperature Port 15 PoE 1 word 16 bits HEX 0x186E 36255 Temperature 87 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 16 PoE 1 word 16 bits HEX 0x186F 36256 Temperature Port 17 PoE 1 word 16 bits HEX 0x1870 36257 Temperature Port 18 PoE 1 word 16 bits HEX 0x1871 36258 Temperature Port 19 POE 1 word 16 bits HEX 0x1872 36259 Temperature Port 20 PoE 1 word 16 bits HEX 0x1873 36260 Temperature Port 21 PoE 1 word 16 bits HEX 0x1874 36261 Temperature Port 22 PoE 1 word 16 bits HEX 0x1875 36262 Temperature Port 23 PoE 1 word 16 bits HEX 0x1876 36263 Temperature Port 24 PoE 1 word 16 bits HEX 0x1877 36264 Temperature Port 25 PoE 1 word 16 bits HEX 0x1878 36265 Temperature Port 26 PoE 1 word 16 bits HEX 0x1879 36266 Temperature Port 27 PoE 1 word 16 bits HEX 0x187A 36267 Temperature Port 28 PoE 1 word 16 bits HEX 0x187B 36268 Temperature Port 29 PoE 1 word 16 bits HEX 0x187C 36269 Temperature Port 30 PoE 1 word 16 bits HEX 0x187D 36270 Temperature Port 31 PoE 1 word 16 bits HEX 0x187E 36271 Temperature Port 32 PoE 1 word 16 bits HEX 0x187F 36272 Temperature 88 MANAGING SWITCH Table 4 1 Modbu
13. 10M e Fast Ethernet e Amber 100M e Off 10M The following view applies to EKI 5729F and EKI 5729FI Figure 1 3 Front View Table 1 6 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 10 PRODUCT OVERVIEW Table 1 6 Front View Continued No Item Description 2 ETH port Eight 10 100 1000BaseT X ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 3 LNK ACT LED Link activity LED 4 Speed LED Gigabit Ethernet e Green 1000M e Amber 100M e Off 10M 5 ETH port Two 100 1000Base FX SFP ports The following view applies to EKI 5525S EKI 5525SI EKI 5525M and EKI 5525MI 1 MAR 5 e E a Figure 1 4 Front View Table 1 7 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 2 ETH port Four RJ45 ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 11 PRODUCT OVERVIEW Table 1 7 Front View Continued No Item Description 3 LNK ACT LED Link activity LED 4 Speed LED Fast Ethernet e Amber 100M e Off 10M 5 SC port EKI 5525S EKI 5525SI One SC single mode port EKI 5525M EKI 5525MI One SC multi mode port
14. 12 Install the wall mount plate on the screws and slide it forward to lock in place see the following figure M Figure 2 5 Wall Mount Installation 13 Once the device is installed on the wall tighten the screws to secure the device Installing and Removing SFP Modules Up to two fiber optic ports are available dependent on model for use in the switch Refer to the technical specifications for details The Gigabit Ethernet ports on the switch are 100 1000Base SFP Fiber ports which require using the 100M or 1G mini GBIC fiber transceivers to work properly Advantech provides completed transceiver models for different distance requirement The concept behind the LC port and cable is quite straight forward Suppose that you are connecting devices and Il contrary to electrical signals optical signals do not require a cir cuit in order to transmit data Consequently one of the optical lines is used to transmit data from device to device II and the other optical line is used transmit data from device II to device for full duplex transmission Remember to connect the Tx transmit port of device to the Rx receive port of device Il and the Rx receive port of device to the Tx transmit port of device II If you make your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B as shown below or A1 to A2 and B1 t
15. 2 words 32 bits HEX 0x230C 38973 Info Error Pack ets Port 8 Rx 2words 32 bits HEX Ox230E 38975 Error Pack ets Port 9 Rx 2 words 32 bits HEX 0x2310 38977 Error Pack ets Port 10 Rx 2 words 32 bits HEX 0x2312 38979 Error Pack ets Port 11 Rx 2 words 32 bits HEX 0x2314 38981 Error Pack ets Port 12 Rx 2 words 32 bits HEX 0x2316 38983 Error Pack ets Port 13 Rx 2 words 32 bits HEX 0x2318 38985 Error Pack ets Port 14 Rx 2words 32 bits HEX 0x231A 38987 Error Pack ets Port 15 Rx 2 words 32 bits HEX 0x231C 38989 Error Pack ets Port 16 Rx 2 words 32 bits HEX Ox231E 38991 Error Pack ets Port 17 Rx 2 words 32 bits HEX 0x2320 38993 Error Pack ets Port 18 Rx 2 words 32 bits HEX 0x2322 38995 Error Pack ets Port 19 Rx 2words 32 bits HEX 0x2324 38997 Error Pack ets Port 20 Rx 2 words 32 bits HEX 0x2326 38999 Error Pack ets 96 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Packet Port 21 Rx 2 words 32 bits HEX 0x2328 39001 Info Error Pack ets Port 22 Rx 2 words 32 bits HEX 0x232A 39003 Error Pack ets Port 23 Rx 2words 32 bits HEX 0x232C 39005 Error Pack ets Port 24 Rx 2 words 32 bits HEX 0x232E 39007 Error Pack ets Port 25 Rx 2words 32 bits HEX 0x2330
16. 38449 Packets Port 2 Rx 4 words 64 bits HEX 0x2104 38453 Packets Port 3 Rx 4 words 64 bits HEX 0x2108 38457 Packets Port 4 Rx 4 words 64 bits HEX 0x210C 38461 Packets Port 5 Rx 4 words 64 bits HEX 0x2110 38465 Packets Port 6 Rx 4words 64 bits HEX 0x2114 38469 Packets Port 7 Rx 4 words 64 bits HEX 0x2118 38473 Packets Port 8 Rx 4 words 64 bits HEX 0x211C 38477 Packets Port 9 Rx 4 words 64 bits HEX 0x2120 38481 Packets Port 10 Rx 4 words 64 bits HEX 0x2124 38485 Packets Port 11 Rx 4 words 64 bits HEX 0x2128 38489 Packets Port 12 Rx 4words 64 bits HEX 0x212C 38493 Packets Port 13 Rx 4words 64 bits HEX 0x2130 38497 Packets Port 14 Rx 4 words 64 bits HEX 0x2134 38501 Packets Port 15 Rx 4words 64 bits HEX 0x2138 38505 Packets 91 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Packet Port 16 Rx 4 words 64 bits HEX 0x213C 38509 Info Packets Port 17 Rx 4words 64 bits HEX 0x2140 38513 Packets Port 18 Rx 4 words 64 bits HEX 0x2144 38517 Packets Port 19 Rx 4 words 64 bits HEX 0x2148 38521 Packets Port 20 Rx 4 words 64 bits HEX 0x214C 38525 Packets Port 21 Rx 4 words 64 bits HEX 0x2150 38529 Packets Port 22 Rx 4 words 64 bits HEX 0x2154 38533 Packets Por
17. BA vi TET LEN RE 57 Configuration Area se aaaea EE Ee ee 57 Managing Switch Discovering Switches uses cetur Egresos s barba Rr Eug 59 4 1 1 First Time lnstallatOn sesse ses terrenae ine tnnc 59 412 Discovering SWHCHES seek ee Be SEE chus xe itn canunt SE ee 61 41 3 Group Management is Es BANE SS ED GEGEE REG ER De Ee EE EE 62 4 1 4 Configuring the SysteM see see Ge AA ee ee ee 67 Modbus TCP Mapping EE EE EE ee eee eee 70 4 2 1 Modbus TCP Mapping Table esse see ee ee ee ee Re ee 71 Federal Communication Commission Interference Statement For further certification information please go to www advantech com Declaration of Conformity CE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring We recommend the use of shielded cables This kind of cable is available from Advantech Please contact your local supplier for ordering information This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to protect the product from being damaged by ESD Electrostatic Discharge and EMI leakage we strongly recommend the use of CE compliant industrial enclosure products FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits
18. EKI 5729F EKI 5729FI 6 8 watts e EKI 5725FP EKI 5725FPI 89 watts e EKI 5528 EKI 5528l 3 6 watts e EKI 5526 EKI 5526l 3 84 watts e EKI 5726 EKI 5726I 8 watts e EKI 5726F EKI 5726FI 9 6 watts e EKI 5629C EKI 5629CI 5 8 watts e EKI 5626C EKI 5626CI 8 2 watts e EKI 5624P EKI 5624PI 60 watts e EKI 5729P EKI 5729PI 65 watts Power Input e 12V 48V 8 4V 52 8V redundant dual inputs e 24V 48V 16 8V 62 4V only for EKI 5725FP EKI 5725FPI e 12V 24V 9V 36V only for EKI 5624P EKI 5624PI and EKI 5729P EKI 5729PI PRODUCT OVERVIEW Table 1 3 Specifications Continued Specifications Description Certifications Safety e EC EN 60950 1 UL508 e UL61010 1 UL61010 2 201 Only for EKI 5729P EKI 5729PI EKI 5624P EKI 5624PI and EKI 5725FP EKI 5725FPI e Class 1 Division 2 IECEx ATEX EMC e CE FCC e e Mark Only for EKI 5728 EKI 57281 EKI 5729F EKI 5729F1 EMI EN 55011 55022 Class A EN 61000 6 4 FCC Part 15 Subpart B Class A EMS e EN 55024 EN 61000 6 2 e EN 61000 4 2 ESD Level 3 e EN 61000 4 3 RS Level 3 e EN 61000 4 4 EFT Level 3 e EN 61000 4 5 Surge Level 3 e EN 61000 4 6 CS Level 3 e EN 61000 4 8 Magnetic Field Level 3 Shock IEC 60068 2 27 Freefall IEC 60068 2 32 Vibration IEC 60068 2 6 PRODUCT OVERVIEW 1 3 Hardware Views 1 3 1 Front View The following view applies to EKI 5525 EKI 5525l EKI 5725 and E
19. PW1 and PW 2 is connected the LED is off 4 Loop Solid red When loop detected the LED lights Off No loop detected 22 PRODUCT OVERVIEW System LED Panel only for EKI 5725FP EKI 5725FPI EKI 5624P EKI 5624PI and EKI 5729P EKI 5729PI P1 e P2 o 2 sel 3 EE 4 5 LNK ACT Figure 1 16 System LED Panel Table 1 19 System LED Panel No LED Name LED Color Description 1 PW1 LED Solid green Powered up Off Powered down or not installed 2 PW2 LED Solid green Powered up Off Powered down or not installed 3 P Fail Solid red When PW1 or PW2 is disconnected the LED lights Off When PW1 and PW2 is connected the LED is off 4 Loop Solid red When loop detected the LED lights Off No loop detected 5 PoE depending Solid green PoE activated the PoE ports Off PoE non working SFP only for Solid green SFP activated EKI 5725FP EKI 5725FPI Blinking Data is being transmitted Off SFP non working 23 PRODUCT OVERVIEW 1 3 2 Rear View The following view applies to EKI 5525S EKI 5525SI EKI 5525M EKI 5525MI EKI 5525S ST EKI 5525SI ST EKI 5525M ST EKI 5525MI ST EKI 5525 EKI 5525l EKI 5725 and EKI 5725l Figure 1 17 Rear View Table 1 20 Rear View Description 1 DIN Rail mounting Mounting plate used for the installation to a standard DIN rail plate 24 PRODUCT OVERVIEW
20. SNMP Community Settings selection the read only and read write strings are required In the SNMP Trap Setting selection enter the IP address of the SNMP trap server TE Advantech EKI Device Configuration Utility v1 71 Fille View Management Tools Help r pl alala la B EKI Device Summary System SNMP P ProView Switch SNMP Basic Setting EKI 5725 8 HEKI 5725 Contact ee Serial Device Server location n Favorites E E Serial Ports E 3 System Serial Ports SNMP Community Setting Virtual Com Ports DE SE Read write Sting i SNMP Trap Setting i Server Apply Undo Tuesday October 28 2014 9 56 34 AM E Figure 4 11 Setting SNMP Setting PoE 1 Select the device to configure by clicking on it 2 In the Configuration Area select the PoE tab MANAGING SWITCH 3 Select the radio box next to the target port then click on it to check and enable the PoE function on that port To disable the PoE function on the port click on the radio box to unselect it 4 Click Refresh to update the PoE status for each port Each port displays the current enabled or disabled state in addition to the following information e Voltage V e Current mA e Power W e Temperature Celsius Advantech EKI Device Configuration Utility v1 71 X M mM M EE EN as Fi
21. View Management Tools Help amp N sd ala lal 8 EKI Device Summary System SNMP PoE 5 89 ProView Switch E i EKI 5728P Firmware Version 1 02 4 EKI S728P Eth 1 192 169 1 1 Device Name Favorites S Serial Ports EKI 5728P 3 A System Serial Ports B Virtual Com Ports Devica Description Gigabit Ethernet Indastrial PoE ProView Switch Iv Enable ProView Feaares Modbus TCP Host Idle Time s 10 F LLDP M Enable LLDP Feature LLDP Interval HO n Li K1 5728P Ethernet Port Tuesday January 13 2015 4 04 10 PM Figure 4 9 Changing Device Name The device name is changed Setting Modbus TCP Idle Time 1 Select the device to configure by clicking on it 2 In the Configuration Area select the System tab 3 Locate the Modbus TCP Host Idle Time s field 4 Enter a variable representing the idle time for the Modbus TCP host function ProView provides the following information to SCADA through Modbus TCP e Vendor Name e Production Name b 3 i MANAGING SWITCH e Firmware Version e Ethernet MAC Address e IP Address e Port Status e Port Speed e Flow Control e Port Description e Link Up Counter e PoE Status e Tx Packets Counter e Rx Packets Counter e 1x Error Packets Counter e Rx Error Packets Counter 5 Click Apply to configure the function y Advantech EK Device Configuration Utility v1 71 File View Management To
22. byte 1 Word 0 Lo byte 0 Word 1Hi byte 0 Word 1 Lo byte R Word 2 Hi byte X Word 2 Lo byte Word 3 Hi byte R Word 3 Lo byte J Word 4 Hi byte 4 Word 4 Lo byte 5 Word 5 Hi byte Word 5 Lo byte 0 Port 1 20 words 40 chars ASCII 0x1400 35121 Description Port 2 20 words 40 chars ASCII 0x1414 35141 Description Port 3 20 words 40 chars ASCII 0x1428 35161 Description Port 4 20 words 40 chars ASCII 0x143C 35181 Description Port 5 20 words 40 chars ASCII 0x1450 35201 Description 78 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 6 20 words 40 chars ASCII 0x1464 35221 Description Port 7 20 words 40 chars ASCII 0x1478 35241 Description Port 8 20 words 40 chars ASCII 0x148C 35261 Description Port 9 20 words 40 chars ASCII 0x14A0 35281 Description Port 10 20 words 40 chars ASCII 0x14B4 35301 Description Port 11 20 words 40 chars ASCII 0x14C8 35321 Description Port 12 20 words 40 chars ASCII 0x14DC 35341 Description Port 13 20 words 40 chars ASCII 0x14F0 35361 Description Port 14 20 words 40 chars ASCII 0x1504 35381 Description Port 15 20 words 40 chars ASCII 0x1518 35401 Description Port 16 20 words 40
23. chars ASCII 0x152C 35421 Description Port 17 20 words 40 chars ASCII 0x1540 35441 Description Port 18 20 words 40 chars ASCII 0x1554 35461 Description Port 19 20 words 40 chars ASCII 0x1568 35481 Description Port 20 20 words 40 chars ASCII 0x157C 35501 Description Port 21 20 words 40 chars ASCII 0x1590 35521 Description Port 22 20 words 40 chars ASCII 0x15A4 35541 Description Port 23 20 words 40 chars ASCII 0x15B8 35561 Description Port 24 20 words 40 chars ASCII 0x15CC 35581 Description Port 25 20 words 40 chars ASCII 0x15E0 35601 Description 79 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 26 20 words 40 chars ASCII Ox15F4 35621 Description Port 27 20 words 40 chars ASCII 0x1608 35641 Description Port 28 20 words 40 chars ASCII 0x161C 35661 Description Port 29 20 words 40 chars ASCII 0x1630 35681 Description Port 30 20 words 40 chars ASCII 0x1644 35701 Description Port 31 20 words 40 chars ASCII 0x1658 35721 Description Port 32 20 words 40 chars ASCII 0x166C 35741 Description Link Up 1 word 16 bits HEX 0x1700 35889 Link Up Counter Counter Ox171F 35920 Ex port link up counter 13 Received MODBUS response 0x000D Port 1 Link 1 word 16 bits HEX 0x1700 35889 Up Counter
24. ets Port 8 Tx 2 words 32 bits HEX 0x220E 38719 Error Pack ets Port 9 Tx 2 words 32 bits HEX 0x2210 38721 Error Pack ets Port 10 Tx 2 words 32 bits HEX 0x2212 38723 Error Pack ets Port 11 Tx 2 words 32 bits HEX 0x2214 38725 Error Pack ets Port 12 Tx 2 words 32 bits HEX 0x2216 38727 Error Pack ets 93 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Packet Port 13 Tx 2 words 32 bits HEX 0x2218 38729 Info Error Pack ets Port 14 Tx 2 words 32 bits HEX 0x221A 38731 Error Pack ets Port 15 Tx 2 words 32 bits HEX 0x221C 38733 Error Pack ets Port 16 Tx 2 words 32 bits HEX OX221E 38735 Error Pack ets Port 17 Tx 2 words 32 bits HEX 0x2220 38737 Error Pack ets Port 18 Tx 2 words 32 bits HEX 0x2222 38739 Error Pack ets Port 19 Tx 2 words 32 bits HEX 0x2224 38741 Error Pack ets Port 20 Tx 2 words 32 bits HEX 0x2226 38743 Error Pack ets Port 21 Tx 2 words 32 bits HEX 0x2228 38745 Error Pack ets Port 22 Tx 2 words 32 bits HEX 0x222A 38747 Error Pack ets Port 23 Tx 2 words 32 bits HEX 0x222C 38749 Error Pack ets Port 24 Tx 2 words 32 bits HEX 0x222bE 38751 Error Pack ets Port 25 Tx 2 words 32 bits HEX 0x2230 38753 Error Pack ets Port 26 Tx 2 words
25. of the switch The device can be mounted onto a standard 35mm 1 37 x 75 mm 3 height DIN rail The devices can be mounted vertically or horizontally Refer to the following guidelines for further information Acorrosion free mounting rail is advisable t When installing make sure to allow for enough space to properly install the cabling Installing the DIN Rail Mounting Kit 1 Insert the top back of the mounting bracket over the DIN rail 2 Push the bottom of the switch towards the DIN rail until it snaps into place Figure 2 1 Installing the DIN Rail Mounting Kit 36 SWITCH INSTALLATION Removing the DIN Rail Mounting Kit 1 Push the switch down to free the bottom of the plate from the DIN rail 2 Rotate the bottom of the device towards you and away from the DIN rail 3 Once the bottom is clear of the DIN rail lift the device straight up to unhook it from the DIN rail Figure 2 2 Removing the DIN Rail 2 3 2 Wall Mounting The wall mounting option provides better shock and vibration resistance than the DIN rail vertical mount When installing make sure to allow for enough space to properly install the cabling Before the device can be mounted on a wall you will need to remove the DIN rail plate 1 Rotate the device to the rear side and locate the DIN mounting plate 2 Remove the screws securing the DIN mounting plate to the rear panel of the switch 3 Remove the DIN mounting plate Store the
26. 0 100BaseT X 2 x 10 100 1000Base T X or 100 1000Base FX SFP e EKI 5624P EKI 5624PI 4 x 10 100BaseT X with PoE 2 x 10 100 1000BaseT X e EKI 5729P EKI 5729PI 8 x 10 100 1000BaseT X with PoE 2 x 10 100 1000BaseT X Power Connector 6 pin screw Terminal Block including relay PRODUCT OVERVIEW Table 1 3 Specifications Continued Specifications Description Physical Enclosure Metal Shell Protection Class IP30 Installation DIN Rail and Wall Mount Dimensions e EKI 5525S EKI 5525SI 27mm x 120mm x 84mm Wx Hx D e EKI 5525M EKI 5525MI 27mm x 120mm x 84mm e EKI 5525S ST EKI 5525SI ST 27mm x 120mm x 84mm e EKI 5525M ST EKI 5525MI ST 27mm x 120mm x 84mm e EKI 5524SS 28 5mm x 120mm x 85 3mm e EKI 5524SSI 28 5mm x 120mm x 85 3mm e EKI 5524MM EKI 5524MMI 28 5mm x 120mm x 85 3mm e EKI 5524SS ST EKI 5524SSI ST 28 5mm x 120mm x 85 3mm e EKI 5524MM ST EKI 5524MMI ST 28 5mm x 120mm x 85 3mm e EKI 5525 EKI 5525 27mm x 120mm x 84mm e EKI 5725 EKI 5725 27mm x 120mm x 84mm e EKl 5728 EKI 5728l 43mm x 120mm x 84mm e EKlI 5729F EKI 5729Fl 43mm x 120mm x 84mm e EKI 5725FP EKI 5725FPI 74mm x 152mm x 105mm e EKI 5528 EKI 5528l 43mm x 120mm x 84mm e EKl 5526 EKI 5526l 74mm x 120mm x 84mm e EKl 5726 EKI 5726l 74mm x 120mm x 84mm e EKlI 5726F EKI 5726Fl 74mm x 120mm x 84mm e EKI 5629C EKI 5629Cl 74mm x 120mm x 84mm e EKI 5626C EKI 5626Cl 74mm x 120mm x 84mm e EKI 5624
27. 0x1831 36194 Current Port 19 PoE 1 word 16 bits HEX 0x1832 36195 Current Port 20 PoE 1 word 16 bits HEX 0x1833 36196 Current Port 24 PoE 1 word 16 bits HEX 0x1834 36197 Current Port 22 PoE 1 word 16 bits HEX 0x1835 36198 Current Port 23 PoE 1 word 16 bits HEX 0x1836 36199 Current 84 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 24 POE 1 word 16 bits HEX 0x1837 36200 Current Port 25 PoE 1 word 16 bits HEX 0x1838 36201 Current Port 26 PoE 1 word 16 bits HEX 0x1839 36202 Current Port 27 PoE 1 word 16 bits HEX 0x183A 36203 Current Port 28 PoE 1 word 16 bits HEX 0x183B 36204 Current Port 29 PoE 1 word 16 bits HEX 0x183C 36205 Current Port 30 PoE 1 word 16 bits HEX 0x183D 36206 Current Port 31 PoE 1 word 16 bits HEX 0x183E 36207 Current Port 32 PoE 1 word 16 bits HEX 0x183F 36208 Current PoE Power 1 word 16 bits HEX 0x1840 36209 0x185F 36240 2 PoE Power W Ex poe power 10 Received MODBUS response Ox000A Port 1 PoE 1 word 16 bits HEX 0x1840 36209 Power Port 2 PoE 1 word 16 bits HEX 0x1841 36210 Power Port 3 PoE 1 word 16 bits HEX 0x1842 36211 Power Port 4 PoE 1 word 16 bits HEX 0x1843 36212 Power Port 5 PoE 1 word 16 bits HEX 0x1844 36213
28. 1 3 6802 1021 81 6 6267 1887 080 363 9494 82 2 3663 9494 65 6442 1000 1800 88 1809 60 3 7725 4188 60 4 537 9188 62 21 769 0525 66 2 248 3140 1 800 425 5070 91 20 39482075 91 80 2545 0206 1300 308 531 61 3 9797 0100 61 2 9476 9300 Poland Warsaw 48 22 33 23 740 41 USA Canada Milpitas CA 1 408 519 3898 Europe Toll Free 00800 2426 8080 Germany Munich 49 89 12599 0 Hilden D dorf 49 2103 97 885 0 France Paris 33 1 4119 4666 Italy Milano 39 02 9544 961 Benelux amp Nordics Breda 31 76 5233 100 UK Reading 44 0118 929 4540 Poland Warsaw 48 22 33 23 740 41 Russia Toll Free 8 800 550 01 50 Moscow 7 495 232 1692 Americas North America Toll Free Cincinnati Milpitas Irvine Brazil Toll Free Saude Sao Paulo Mexico Toll Free Mexico City 1 888 576 9668 1 513 742 8895 1 408 519 3898 1 949 420 2500 0800 770 5355 55 11 5592 5355 1 800 467 2415 52 55 6275 2777 Product Overview Chapter 1 PRODUCT OVERVIEW 1 1 Supported Models Standard Models Table 1 1 Standard Models EKI 5525S EKI 5525M EKI 5525S ST EKI 5525M ST EKI 5524SS EKI 5524MM EKI 5524SS ST EKI 5524MM ST EKI 5525 EKI 5725 EKI 5728 EKI 5729F EKI 5725FP EKI 5528 EKI 5526 EKI 5726 EKI 5726F EKI 5629C EKI 5626C EKI 5624P EKI 5729P Wide Temperature Models Table 1 2 Wide Temperature Models EKI 5525SI EKI 5525MI EKI 5525SI ST EKI 5525M
29. 1 word 16 bits HEX 0x100C 34109 tus Port 14 Sta 1 word 16 bits HEX 0x100D 34110 tus Port 15 Sta 1 word 16 bits HEX 0x100E 34111 tus Port 16 Sta 1 word 16 bits HEX 0x100F 34112 tus Port 17 Sta 1 word 16 bits HEX 0x1010 34113 tus Port 18 Sta 1 word 16 bits HEX 0x1011 34114 tus Port 19 Sta 1 word 16 bits HEX 0x1012 34115 tus Port 20 Sta 1 word 16 bits HEX 0x1013 34116 tus Port 21 Sta 1 word 16 bits HEX 0x1014 34117 tus Port 22 Sta 1 word 16 bits HEX 0x1015 34118 tus Port 23 Sta 1 word 16 bits HEX 0x1016 34119 tus Port 24 Sta 1 word 16 bits HEX 0x1017 34120 tus Port 25 Sta 1 word 16 bits HEX 0x1018 34121 tus Port 26 Sta 1 word 16 bits HEX 0x1019 34122 tus Port 27 Sta 1 word 16 bits HEX 0x101A 34123 tus Port 28 Sta 1 word 16 bits HEX 0x101B 34124 tus Port 29 Sta 1 word 16 bits HEX 0x101C 34125 tus Port 30 Sta 1 word 16 bits HEX 0x101D 34126 tus Port 31 Sta 1 word 16 bits HEX 0x101E 34127 tus Port 32 Sta 1 word 16 bits HEX 0x101F 34128 tus 74 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Port Info Data Type Inter Address Address Description preta Offset 3x tion Hex Port Speed 1 word 16 bits HEX 0x1100 34353 Port Speed OxITIF 34384 0x0000 10M Half
30. 2 Click the drop down menu to select DHCP Auto IP 3 Click Apply to confirm the settings XX Advantech EKI Device Configuration Utility v1 71 File View Management Tools Help dl SS an B EKI Device Basic z ep ProView Switch i EKI 5524MM SC 4 OEKL5524MM SC MAC Address 00 02 53 23 11 22 pee 1 072 1784 514 Serial Device Server Static IP zl a Favorites 5 Serial Ports Address 172 1787 vel System Serial Ports Subnet Mask 255 255 254 0 Virtual Com Ports Default Gateway 172 17 9 254 Apply Undo Tuesday October 28 2014 9 44 25 AM E Figure 4 1 Selecting Networking Setting Static Settings 1 Select Ethernet under the desired device 2 Click the drop down menu to select Static IP 3 Enter the IP Address Subnet Mask and Gateway 59 MANAGING SWITCH 4 Click Apply to confirm the settings ERUIT NUR File View Management Tools Help daan Basie eh ProView Switch d EKI 5524MM SC Gl COEKLS524MM SC MAC Address 000253231122 og Eth 1 1721787 ef Serial Device Server Static IP i B Favorites 58 Serial Ports Address 723787 og System Serial Ports Subnet Mask 255 255 254 0 Virtual Com Ports Default Gateway m 179254 Apply Undo Tuesday October 28 2014 9 42 44 AM Figure 4 2 Co
31. 32 bits HEX 0x2232 38755 Error Pack ets 94 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Packet Port 27 Tx 2words 32 bits HEX 0x2234 38757 Info Error Pack ets Port 28 Tx 2words 32 bits HEX 0x2236 38759 Error Pack ets Port 29 Tx 2 words 32 bits HEX 0x2238 38761 Error Pack ets Port 30 Tx 2 words 32 bits HEX 0x223A 38763 Error Pack ets Port 31 Tx 2 words 32 bits HEX 0x223C 38765 Error Pack ets Port 32 Tx 2words 32 bits HEX OX223E 38767 Error Pack ets Rx Error 2 words 32 bits HEX 0x2300 38961 Rx Error Packets Packets Ox233E 39023 Ex port 1 Rx Packet counen Amount 11223344 Received MODBUS response 0xAB4130 Word 0 0x00AB Word 1 0x4130 Port 1 Rx 2words 32 bits HEX 0x2300 38961 Error Pack ets Port 2 Rx 2 words 32 bits HEX 0x2302 38963 Error Pack ets Port 3 Rx 2words 32 bits HEX 0x2304 38965 Error Pack ets Port 4 Rx 2 words 32 bits HEX 0x2306 38967 Error Pack ets Port 5 Rx 2words 32 bits HEX 0x2308 38969 Error Pack ets Port 6 Rx 2 words 32 bits HEX 0x230A 38971 Error Pack ets 95 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3X tion Hex Packet Port 7 Rx
32. 39009 Error Pack ets Port 26 Rx 2 words 32 bits HEX 0x2332 39011 Error Pack ets Port 27 Rx 2 words 32 bits HEX 0x2334 39013 Error Pack ets Port 28 Rx 2words 32 bits HEX 0x2336 39015 Error Pack ets Port 29 Rx 2 words 32 bits HEX 0x2338 39017 Error Pack ets Port 30 Rx 2words 32 bits HEX 0x233A 39019 Error Pack ets Port 31 Rx 2 words 32 bits HEX 0x233C 39021 Error Pack ets Port 32 Rx 2 words 32 bits HEX Ox233E 39023 Error Pack ets 97
33. 5624P EKI 5624PI 2K entries EKI 5729P EKI 5729PI 8K entries PRODUCT OVERVIEW Table 1 3 Specifications Continued Specifications Description Switch Properties Switching Band e EKI 5525S EKI 5525SI 1 Gbps width e EKI 5525M EKI 5525MI 1 Gbps e EKI 5525S ST EKI 5525SI ST 1 Gbps e EKI 5525M ST EKI 5525MI ST 1 Gbps e EKI 5524SS EKI 5524SSI 1 2 Gbps e EKI 5524MM EKI 5524MMI 1 2 Gbps e EKI 5524SS ST EKI 5524SSI ST 1 2 Gbps e EKI 5524MM ST EKI 5524MMI ST 1 2 Gbps e EKI 5525 EKI 5525l 1 Gbps e EKI 5725 EKI 57251 10 Gbps e EKI 5728 EKI 5728I 16 Gbps e EKI 5729F EKI 5729FI 20 Gbps e EKI 5725FP EKI 5725FPI 10 Gbps e EKI 5528 EKI 5528I 1 6 Gbps e EKI 5526 EKI 5526l 3 2 Gbps e EKI 5726 EKI 5726I 32 Gbps e EKI 5726F EKI 5726FI 36 Gbps e EKI 5629C EKI 5629CI 5 6 Gbps e EKI 5626C EKI 5626CI 7 2 Gbps e EKI 5624P EKI 5624PI 4 8Gbps e EKI 5729P EKI 5729PI 20Gbps PRODUCT OVERVIEW Table 1 3 Specifications Continued Specifications Description Power Power Consump e EKI 5525S EKI 5525SI 2 8 watts Hon e EKI 5525M EKI 5525MI 2 8 watts e EKI 5525S ST EKI 5525SI ST 2 8 watts e EKI 5525M ST EKI 5525MI ST 2 8 watts e EKI 5524SS EKI 5524SSI 4 watts e EKI 5524MM EKI 5524MMI 4 watts e EKI 5524SS ST EKI 5524SSI ST 4 watts e EKI 5524MM ST EKI 5524MMI ST 4 watts e EKI 5525 EKI 5525 2 watts e EKlI 5725 EKI 5725l 2 watts e EKI 5728 EKI 5728l 5 2 watts e
34. 6 Pin 6 Pin 6 Pin 2 Figure 2 11 Ethernet Plug amp Connector Pin Position Maximum cable length 100 meters 328 ft for 10 100 1000BaseT 42 SWITCH INSTALLATION 2 6 Power Supply Installation 2 6 1 Overview POWER DOWN AND DISCONNECT THE POWER CORD BEFORE SERVICING OR WIRING THE A SWITCH Do not disconnect modules or cabling unless the power is first switched off A The device only supports the voltage outlined in the type plate Do not use any other power components except those specifically designated for the switch device Disconnect the power cord before installation or cable wiring The switches can be powered by using the same DC source used to power other devices A DC voltage range of 12 to 48 VDC must be applied between the V1 terminal and the V1 terminal PW1 see the following illustrations A Class 2 power supply is required to main tain a UL60950 panel listing The chassis ground screw terminal should be tied to the panel or chassis ground A redundant power configuration is supported through a secondary power supply unit to reduce network down time as a result of power loss EKI 5000 Series support 12 and 48 VDC Dual power inputs are supported and allow you to connect a backup power source Single DC Power Redundant DC Power Chassis GND pane One DC Supply Dual DC Supplies Figure 2 12 Power Wiring for EKI 5000 Series 2 6 2 Considerations Take into considerat
35. 64 bits HEX 0x203C 38253 Info Packets Port 17 Tx 4words 64 bits HEX 0x2040 38257 Packets Port 18 Tx 4 words 64 bits HEX 0x2044 38261 Packets Port 19 Tx 4 words 64 bits HEX 0x2048 38265 Packets Port 20 Tx 4 words 64 bits HEX 0x204C 38269 Packets Port 21 Tx 4 words 64 bits HEX 0x2050 38273 Packets Port 22 Tx 4 words 64 bits HEX 0x2054 38277 Packets Port 23 Tx 4 words 64 bits HEX 0x2058 38281 Packets Port 24 Tx 4 words 64 bits HEX 0x205C 38285 Packets Port 25 Tx 4 words 64 bits HEX 0x2060 38289 Packets Port 26 Tx 4 words 64 bits HEX 0x2064 38293 Packets Port 27 Tx 4 words 64 bits HEX 0x2068 38297 Packets Port 28 Tx 4words 64 bits HEX OX206C 38301 Packets Port 29 Tx 4 words 64 bits HEX 0x2070 38305 Packets Port 30 Tx 4words 64 bits HEX 0x2074 38309 Packets Port 31 Tx 4 words 64 bits HEX 0x2078 38313 Packets Port 32 Tx 4 words 64 bits HEX 0x207C 38317 Packets 90 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Packet Rx Packets 4words 64 bits HEX 0x2100 38449 Rx Packets Info Counter 0x217C 38573 Ex port 1 Rx Packet Amount 11223344 Received MODBUS response 0xAB4130 Word 0 0x0000 Word 1 0x0000 Word 2 0x00AB Word 3 0x4130 Port 1 Rx 4 words 64 bits HEX 0x2100
36. 9 PoE 1 word 16 bits HEX 0x1808 36153 Voltage Port10 PoE 1 word 16 bits HEX 0x1809 36154 Voltage Port 11 PoE 1 word 16 bits HEX 0x180A 36155 Voltage Port 12 PoE 1 word 16 bits HEX 0x180B 36156 Voltage Port 13 PoE 1 word 16 bits HEX 0x180C 36157 Voltage Port 14 PoE 1 word 16 bits HEX 0x180D 36158 Voltage Port15 PoE 1 word 16 bits HEX 0x180E 36159 Voltage Port16 PoE 1 word 16 bits HEX 0x180F 36160 Voltage Port17 PoE 1 word 16 bits HEX 0x1810 36161 Voltage 82 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 18 PoE 1 word 16 bits HEX 0x1811 36162 Voltage Port 19 PoE 1 word 16 bits HEX 0x1812 36163 Voltage Port 20 PoE 1 word 16 bits HEX 0x1813 36164 Voltage Port 21 PoE 1 word 16 bits HEX 0x1814 36165 Voltage Port 22 PoE 1 word 16 bits HEX 0x1815 36166 Voltage Port 23 PoE 1 word 16 bits HEX 0x1816 36167 Voltage Port 24 PoE 1 word 16 bits HEX 0x1817 36168 Voltage Port 25 PoE 1 word 16 bits HEX 0x1818 36169 Voltage Port 26 PoE 1 word 16 bits HEX 0x1819 36170 Voltage Port 27 PoE 1 word 16 bits HEX 0x181A 36171 Voltage Port 28 PoE 1 word 16 bits HEX 0x181B 36172 Voltage Port 29 PoE 1 word 16 bits HEX 0x181C 36173 Voltage Port 30 PoE 1 word 16 bits HEX 0x181D 36174 Voltage Port 31 PoE 1 word 16 b
37. DIN mounting plate and provided screws for later use 4 Align the wall mounting plates on the rear side The screw holes on the device and the mounting plates must be aligned see the following illustration SWITCH INSTALLATION 5 Secure the wall mount plates with M3 screws see the following figure Phy ad t Figure 2 3 Installing Wall Mount Plates Once the wall mounting plates are secure on the device you will need to attach the wall screws x3 6 Locate the installation site and place the switch against the wall making sure it is the final installation location 7 Use the wall mount plates as a guide to mark the locations of the screw holes Drill four holes over the four marked locations on the wall keeping in mind that the holes must accommodate wall sinks in addition to the screws 9 Insert the wall sinks into the walls 10 Insert the screws into the wall sinks Leave a 2 mm gap between the wall and the screw head to allow for wall mount plate insertion E i 3 0 mm Figure 2 4 Securing Wall Mounting Screws vw e Make sure the screws dimensions are suitable for use with the wall mounting plate e Do not completely tighten the screws into the wall A final adjustment may be needed before fully securing the wall mounting plates on the wall 11 Align the wall mount plate over the screws on the wall 38 SWITCH INSTALLATION 2 4 39
38. EKI 5000 Series ProView Series Ethernet Switches 000000 ry 00000 z s Ee 5 een EKI 5528 EES 0000 EKI 5729FI AE AAG OOOO g TN DA rr TT als n ha B EE od of 5 N Al HOF of A 6 gs ni 6 y Ti 7 aa of f i of 3 7 i TA on 8 EL UL gi i L IL P N 2015 EKI 5000 01 Version Edition 4 2015 06 w eee an AD ANTECH Sate Enabling an Intelligent Planet Content Chapter 1 1 1 1 2 1 3 1 4 Chapter 2 2 1 2 2 2 3 2 4 2 5 2 6 Chapter 3 3 1 3 2 3 3 Product Overview Supported ModelS ux Saee or rcr one ewe eee rp ores 1 Specifications p T 2 Hardware Views 5 eine eee Renee Rd RR ee eee ee ewe ewe 8 ESA Front VW Em 8 dud Rear VIEW asus EE ORAN DM Eaa 24 13 3 TOPVIEW e 28 Ta BOOM VIEW Cm 31 x ja E 33 Switch Installation Installation Guidelines ss ss ecce ee uk ue rer ERE Gum 35 2 1 1 Connecting Hardware sesse ee ee ee ee ee AA ee ee 35 Verifying Switch Operation sssaaa EE EE se ee de ee ee 35 Installing the Switch sesse e
39. I ST EKI 5524SSI EKI 5524MMI EKI 5524SSI ST EKI 5524MMI ST EKI 5525l EKI 5725l EKI 5728l EKI 5729FI EKI 5725FPI EKI 5528l EKI 5526l EKI 57261 EKI 5726FI EKI 5629CI EKI 5626CI EKI 5624PI EKI 5729PI PRODUCT OVERVIEW 1 2 Specifications Table 1 3 Specifications Specifications Description Interface VO Port e EKI 5525S EKI 5525SI 4 x RJ45 1 x SC single mode e EKI 5525M EKI 5525MI 4 x RJ45 1 x SC multi mode e EKI 5525S ST EKI 5525SI ST 4 x RJ45 1 x ST single mode e EKI 5525M ST EKI 5525MI ST 4 x RJ45 1 x ST multi mode e EKI 5524SS EKI 5524SSI 4 x RJ45 2 x SC single mode e EKI 5524MM EKI 5524MMI 4 x RJ45 2 x SC multi mode e EKI 5524SS ST EKI 5524SSI ST 4 x RJ45 2x ST single mode e EKI 5524MM ST EKI 5524MMI ST 4 x RJ45 2 x ST multi mode e EKI 5525 EKI 5525 5 x 10 100BaseT X e EKI 5725 EKI 5725 5 x 10 100 1000BaseT X e EKI 5728 EKI 5728l 8 x 10 100 1000BaseT X e EKI 5729F EKI 5729FI 8 x 10 100 1000BaseT X 2 x 100 1000Base FX SFP e EKI 5725FP EKI 5725FPI 4 x 10 100 1000BaseT X with PoE 1 x 100 1000Base FX SFP e EKI 5528 EKI 5528 8 x 10 100BaseT X e EKI 5526 EKI 5526I 16 x 10 100BaseT X e EKI 5726 EKI 5726l 16 x 10 100 1000BaseT X e EKI 5726F EKI 5726FI 16 x 10 100 1000BaseT X 2 x 100 1000Base FX SFP e EKI 5629C EKI 5629CI 8 x 10 100BaseT X 2 x 10 100 1000Base T X or 100 1000Base FX SFP e EKI 5626C EKI 5626CI 16 x 1
40. KI 5725l Figure 1 1 Front View Table 1 4 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 2 ETH port EKI 5525 EKI 5525l Four 10 100BaseT X ports EKI 5725 EKI 5725l Four 10 100 1000BaseT X ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 3 LNK ACT LED Link activity LED PRODUCT OVERVIEW Table 1 4 Front View Continued No Item Description 4 Speed LED e Gigabit Ethernet e Green 1000M e Amber 100M e Off 10M e Fast Ethernet e Amber 100M e Off 10M 5 ETH port EKI 5525 EKI 5525l One 10 100BaseT X port EKI 5725 EKI 57251 One 10 100 1000BaseT X port The following view applies to EKI 5528 EKI 5528l EKI 5728 and EKI 5728l Figure 1 2 Front View Table 1 5 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details PRODUCT OVERVIEW Table 1 5 Front View Continued No Item Description 2 ETH port EKI 5528 EKI 55281 Eight 10 100BaseT X ports EKI 5728 EKI 5728I Eight 10 100 1000BaseT X ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 3 LNK ACT LED Link activity LED 4 Speed LED e Gigabit Ethernet e Green 1000M e Amber 100M e Off
41. Link 1 word 16 bits HEX 0x1715 35910 Up Counter Port 23 Link 1 word 16 bits HEX 0x1716 35911 Up Counter Port 24 Link 1 word 16 bits HEX 0x1717 35912 Up Counter Port 25 Link 1 word 16 bits HEX 0x1718 35913 Up Counter Port 26 Link 1 word 16 bits HEX 0x1719 35914 Up Counter Port 27 Link 1 word 16 bits HEX 0x171A 35915 Up Counter Port 28 Link 1 word 16 bits HEX 0x171B 35916 Up Counter Port 29 Link 1 word 16 bits HEX 0x171C 35917 Up Counter Port 30 Link 1 word 16 bits HEX 0x171D 35918 Up Counter Port 31 Link 1 word 16 bits HEX Ox171E 35919 Up Counter 81 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 32 Link 1 word 16 bits HEX 0x171F 35920 Up Counter PoE Voltage 1 word 16 bits HEX 0x1800 36145 PoE Voltage V Ox181F 36176 Ex poe voltage 5 Received MODBUS response 0x0005 Port 1 PoE 1 word 16 bits HEX 0x1800 36145 Voltage Port 2 PoE 1 word 16 bits HEX 0x1801 36146 Voltage Port 3 PoE 1 word 16 bits HEX 0x1802 36147 Voltage Port 4 PoE 1 word 16 bits HEX 0x1803 36148 Voltage Port 5 PoE 1 word 16 bits HEX 0x1804 36149 Voltage Port 6 PoE 1 word 16 bits HEX 0x1805 36150 Voltage Port 7 PoE 1 word 16 bits HEX 0x1806 36151 Voltage Port 8 PoE 1 word 16 bits HEX 0x1807 36152 Voltage Port
42. MENT RISQUE D EXPLOSI ON Remplacement de tous les composants peut nuire la conformit de Classe I Division 2 ATEX Information ATEX Directive 94 9 EC as amended relating to Group II Category 3 locations Il 3G Standard EN 60079 0 2012 A11 2013 EN 60079 15 2010 Conditions of safe use The equipment shall only be used in an area of not more than pollution degree 2 as defined in IEC 60664 1 The equipment shall be installed in an enclosure that provides a degree of protection not less than IP 54 in accordance with EN 60079 15 and accessible only by the use of a tool Transient protection shall be provided that is set at a level not exceeding 140 of the peak rated voltage value at the supply terminals to the equipment Safety Instructions Read these safety instructions carefully Keep this user manual for later reference Disconnect this equipment from any AC outlet before cleaning Use damp cloth Do not use liquid or spray detergents for cleaning For plug in equipment the power outlet socket must be located near the equipment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause danage The openings on the enclosure are fo air convection Protect the equipment from over heating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipm
43. N TROLLED ENVIRONMENT Product Warranty 5 years Company Address ADVANTECH CO LTD HERE APR a 1 ALY 20 LN 26 RUEIGUANG RD NEIHU DISTRICT TAIPEI 114 TAIWAN Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for five years from the date of purchase This warranty does not apply to any products which have been repaired or altered by per sons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any on screen messages you get when the problem occurs 2 Call your dealer and describe the problem Ple
44. P EKI 5624PI 74mm x 152mm x 105mm e EKI 5729P EKI 5729PI 74mm x 152mm x 105mm LED Display System LED PWR1 PWR2 P Fail Loop detection PoE only for EKI 5725FP EKI 5725F PI Port LED Link Speed Activity PoE only for EKI 5725FP EKI 5725FPI EKI 5624P EKI 5624PI and EKI 5729P EKI 5729P1 PRODUCT OVERVIEW Table 1 3 Specifications Continued Specifications Description Environment Operating Tem e Wide Temperature 40 C 75 C 40 F 167 F perature e Standard Temperature e Non PoE Models 10 C 60 C 14 F 140 F e PoE Models 25 C 60 C 4 F 140 F Storage Tempera 40 C 85 C 40 F 185 F ture Ambient Relative 10 95 non condensing Humidity Switch Properties MAC Address e EKI 5525S EKI 5525SI 2K entries e EKI 5525M EKI 5525MI 2K entries e EKI 5525S ST EKI 5525SI ST 2K entries EKI 5525M ST EKI 5525MI ST 2K entries EKI 5524SS EKI 5524SSI 2K entries e EKI 5524MM EKI 5524MMI 2K entries e EKI 5524SS ST EKI 5524SSI ST 2K entries EKI 5524MM ST EKI 5524MMI ST 2K entries EKI 5525 EK1 5525I 2K entries e EKI 5725 EKI 5725l 2K entries e EKI 5728 EKI 5728l 8K entries EKI 5729F EKI 5729FI 8K entries EKI 5725FP EKI 5725FPI 2K entries e EKI 5528 EKI 5528l 8K entries e EKI 5526 EKI 5526 8K entries EKI 5726 EKI 5726l 8K entries EKI 5726F EKI 5726FI 8K entries e EKI 5629C EKI 5629CI 8K entries e EKI 5626C EKI 5626CI 8K entries EKI
45. RVIEW Table 1 11 Front View Continued Description 4 Speed LED Fast Ethernet e Amber 100M e Off 10M The following view applies to EKI 5629C and EKI 5629CI ud Figure 1 9 Front View Table 1 12 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 2 ETHport Eight 10 100BaseT X ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 3 LNK ACT LED Link activity LED 4 Speed LED Fast Ethernet e Amber 100M e Off 10M 5 ETH port Two 10 100 1000BaseT X ports 16 PRODUCT OVERVIEW 17 Table 1 12 Front View Continued ETH port Description Two 100 1000Base FX SFP ports The following view applies to EKI 5626C and EKI 5626CI Table 1 13 Front View L Figure 1 10 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 2 ETH port Sixteen 10 100BaseT X ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 3 LNK ACT LED Link activity LED 4 Speed LED Fast Ethernet e Amber 100M e Off 10M 5 ETH port Two 10 100 1000BaseT X ports 6 ETH port Two 100 1000Base FX SFP ports
46. The following view applies to EKI 5728 EKI 5728l EKI 5729F EKI 5729FI EKI 5528 EKI 5528l EKI 5524SS EKI 5524SSI EKI 5524MM EKI 5524MMI EKI 5524SS ST EKI 5524SSI ST EKI 5524MM ST and EKI 5524MMI ST Figure 1 18 Rear View Table 1 21 Rear View Description 1 DIN Rail mounting Mounting plate used for the installation to a standard DIN rail plate PRODUCT OVERVIEW The following view applies to EKI 5526 EKI 5526l EKI 5629C EKI 5629Cl EKI 5626C EKI 5626Cl EKI 5726 EKI 5726l EKI 5726F and EKI 5726FI Figure 1 19 Rear View Table 1 22 Rear View Description 1 DIN Rail mounting Mounting plate used for the installation to a standard DIN rail plate PRODUCT OVERVIEW The following view applies to EKI 5725FP EKI 5725FPI EKI 5624P EKI 5624PI EKI 5729P and EKI 5729PI Figure 1 20 Rear View Table 1 23 Rear View Description 1 DIN Rail mounting Mounting plate used for the installation to a standard DIN rail plate PRODUCT OVERVIEW 1 3 3 Top View The following view applies to EKI 5525S EKI 5525SI EKI 5525M EKI 5525MI EKI 5525S ST EKI 5525SI ST EKI 5525M ST EKI 5525MI ST EKI 5525 EKI 5525l EKI 5725 and EKI 5725l DC 12 48V PWR2 1A 24V PWR1 eo eooo ee eoo 0o 1 eeee ee eooo V2 V2 LVJ V1 Vit P Fail Figure 1 21 Top View Table 1 24 Top View No Item Description 1 Ter
47. ae ER RES RR RR ERES NE 36 2 3 1 DIN Rail Mounind issie ten UO ntu Ne equites 36 232 WallsMODDUI susse patei ien EED bags ee ee er 37 Installing and Removing SFP Modules 04 39 2 41 Installing SEP Modules eerie cone intimes 40 2 4 2 Removing SFP Modules eese 41 Connecting the Switch to Ethernet Ports 05 42 2 5 1 RJ45 Ethernet Cable Wiring eseseeesesssse 42 Power Supply Installation 2245259 ee mr RR BAG Rohre d 43 2 6 1 AWN 43 2 6 2 Considerations EE ER oe 43 2 6 3 Grounding the Device sees ee ee ee ee 44 2 6 4 Wiring a Relay Contact sesse see ee ee AA ee 45 2 6 5 Wiring the Power INDUIS sees ee ee RR ee ee ee ee 45 Configuration Utility OvervieW ee 49 Enabling ProView Function ie Es ee se ee Se se ee de 49 Installing the Configuration Utility EE EE EE EE ds 50 Chapter 3 4 3 5 3 6 3 7 3 8 3 9 3 10 4 1 4 2 Utility Menu Map lseseeeeenn RR 53 Ment C ee EE Re RE OE M 54 35 1 View MED ien sk en N N GER AN RGN 54 3 5 2 Management Menu ccccccceeeeeeeescceeeeeeeeeeeeeaeeeeeeeeeeeeeees 56 Aas Help i i erc 56 WOO Bala PI crure 57 INGO VIEW EE Re Wah uua x Vane mene eodd dun M eked 57 Information Panel 4 53 59 4 dus 3a oh Ros ot D do eee eae Sos 57 Status
48. are designed to provide reason able protection against harmful interference when the equipment is operated in a commer cial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Warnings for Class 1 Division 2 The following statements are required to appear for Class 1 Division 2 requirements These devices are open type devices that are to be installed in an enclosure with tool removable cover door that is suitable for the environment WARNING This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only WARNING EXPLOSION HAZARD Do not connect or disconnect equipment unless power has been removed or the area is known to be non hazardous WARNING EXPLOSION HAZARD Substitution of any components may impair suitability for Class Division 2 AVERTISSEMENT Ce quipement est adapt une utilisation en Classe I Division 2 Groupes A B C et D ou non dangereux AVERTISSEMENT RISQUE D EXPLOSION Ne pas brancher ou d brancher l quipe ment que l alimentation a t retir ou la r gion est connue pour tre non dangereux AVERTISSE
49. ase have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authori zation number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippa ble container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer Conventions Warning signs are used to identify immediate hazards for property damage injury A or death CAUTION SIGNS ARE USED WARN AGAINST POTENTIAL HAZARDS OR TO CAUTION AGAINST A UNSAFE PRACTICES Note signs are used to provide additional information for the device or settings Copyright Copyright 2015 Advantech Inc All rights reserved No part of this publication may be reproduced adapted stored in a retrieval system translated into any language or transmit ted in any form or by any means without the written permission of the manufacturer vi Technical Support and Assistance 1 Visit the Advantech web site at www advantech com support where you can find the lat est information about the product 2 Contract your distributor sales representative or Advantech s customer service center
50. bits HEX 0x120D 34622 Control Port 15 Flow 1 word 16 bits HEX 0x120E 34623 Control Port 16 Flow 1 word 16 bits HEX 0x120F 34624 Control Port 17 Flow 1 word 16 bits HEX 0x1210 34625 Control Port 18 Flow 1 word 16 bits HEX 0x1211 34626 Control Port 19 Flow 1 word 16 bits HEX 0x1212 34627 Control Port 20 Flow 1 word 16 bits HEX 0x1213 34628 Control Port 21 Flow 1 word 16 bits HEX 0x1214 34629 Control Port 22 Flow 1 word 16 bits HEX 0x1215 34630 Control Port 23 Flow 1 word 16 bits HEX 0x1216 34631 Control Port 24 Flow 1 word 16 bits HEX 0x1217 34632 Control Port 25 Flow 1 word 16 bits HEX 0x1218 34633 Control 77 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 26 Flow 1 word 16 bits HEX 0x1219 34634 Control Port 27 Flow 1 word 16 bits HEX 0x121A 34635 Control Port 28 Flow 1 word 16 bits HEX 0x121B 34636 Control Port 29 Flow 1 word 16 bits HEX 0x121C 34637 Control Port 30 Flow 1 word 16 bits HEX 0x121D 34638 Control Port 31 Flow 1 word 16 bits HEX Ox121E 34639 Control Port 32 Flow 1 word 16 bits HEX 0x121F 34640 Control Port Descrip 20 words 40 chars ASCII 0x1400 35121 Port Description tion 0x166C 35741 Port Description 100RX RJ45 Word 0 Hi
51. clicking the Clearing Device List and Search Again P button The function clears the listing of the devices You can use the Search function again to detect any devices connected to the network domain 4 1 3 Group Management Creating Groups Groups are best used to identify a set of devices with a common characteristic and to better organize the device pool To create a favorite group please follow the instructions as follows 1 Right click Favorite to display the settings 2 Select Create Group to enter group name 62 MANAGING SWITCH 3 Enter a group name and click OK Advantech EKI Device Configuration Utility v1 71 cji x File View Management Tools Help Rd S aa B Bes EKI Device E ProView Switch E EKI 5725 Ej EKI 5725 iet Eth 1 192 168 1 1 Serial Device Server an Favorites TEE Serial Ports t System Serial Ports Virtual Com Ports Tuesday October 28 2014 9 49 39 AM a E Figure 4 5 Adding a Group The group is created and is available in the Favorite s List MANAGING SWITCH Favorite s List A favorite s list is simple a way to organize the available devices by a category There are three ways to create a favorite s list selecting a device selecting an IP address and selecting an IP address range The following guidelines allow you to create a favorite s list Adding a Device 1 Right clic
52. ed Catelog Data Type Inter preta Address Offset Address 3X MANAGING SWITCH Description System Info Vendor Name Advantech 16 words 32 chars tion ASCII Hex 0x0010 30017 Vendor Name Advan tech Word 0 Hi byte A Word 0 Lo byte d Word 1 Hi byte v Word 1 Lo byte a Word 2 Hi byte n Word 2 Lo byte t Word 3 Hi byte e Word 3 Lo byte c Word 4 Hi byte h Word 4 Lo byte 0 Product Name EKI xxxx 16 words 32 chars ASCII 0x0020 30033 Product Name EKI xxxx Word 0 Hi byte E Word 0 Lo byte K Word 1 Hi byte l Word 1 Lo byte Word 2 Hi byte x Word 2 Lo byte x Word 3 Hi byte x Word 3 Lo byte x Word 4 Hi byte 0 Firmware Version 2 words 32 bits HEX 0x020A 30523 Firmware Version Word 0 Hi byte major Word 0 Lo byte minor Word 1 Hi byte release Word 1 Lo byte build Ethernet MAC Address 3 words 48 bits HEX 0x020E 30527 Ethernet MAC Address Ex MAC 00 19 CB 01 02 03 Word 0 Hi byte 0x00 Word 0 Lo byte 0x19 Word 1 Hi byte OXCB Word 1 Lo byte 0x01 Word 2 Hi byte 0x02 Word 2 Lo byte 0x03 72 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex System Revision 16 words 32 c
53. ent to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions and warning on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient over voltage Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel e f one of the following situations arises get the equipment checked by service person nel e The power cord or plug is damaged e Liquid has peretrated into the equipment e The equipment has been exposed to moisture e The equipment does not work well or you cannot get it to work according to the user manual e The equipment has been dropped and damaged e he equipment has obvious signs of breakage e Instructions for installation in a pollution Degree 2 environment or equivalent statement e PoE requirements This product was in door used and not connected to outside plant so user manual shall have the description as below or equivalent The equipment is to be connected only to PoE networks without routing to the outside plant e Do NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 40 C 40 F OR ABOVE 75 C 167 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CO
54. es EKI Device Configuration Utility Advantech EKI Device Configuration Utility Setup E IX t while Advantech EKI Des nfiguration Utility is being installed Extract ipxconfig dll 100 nfiguration Utility Extract ipxconfig dll 100 Nullsoft Install System v2 46 Figure 3 4 InstallShield Wizard 3 of 4 Once the installation of the package is finished a Configuration Utility Setup screen dis plays Click Finish to conclude the process and exit the InstallShield Wizard Advantech EKI Device Configuration Utility Setup di Ja Completing the Advantech EKI Device Configuration Utility Setup Wizard Advantech EKI Device Configuration Utility has been installed on your computer Click Finish to close this wizard Nullsoft Install System v2 46 Figure 3 5 InstallShield Wizard 4 of 4 52 CONFIGURATION UTILITY 3 4 Utility Menu Map The EKI Configuration Utility can be installed on different operating systems however Win dows 7 is the recommended version Click Start gt All Programs gt EKI Device Configuration Utility gt Advantech EKI Device Configuration Utility The EKI Device Configuration Utility screen appears see the follow ing figure TE Advantech EKI Device Configuration Utility v1 71 sel x jJ 1 File View Management Tools Help 2 e 4 2 9 eal B Dad Priv Sikh
55. guration must be connected and powered on see Installation Guidelines on page 35 1 From your Windows desktop locate the Start button to open the Start Menu 2 Navigate to All Programs gt EKI Device Configuration Utility 3 Locate Advantech EKI Device Configuration Utility and right click on it From the pop up menu select Run as Administrator See your network administrator to obtain the privileges required 4 A security screen displays select Yes to continue 5 Select Search Again to detect any connected devices Once a device is detected it is listed under the EKI Device listing in the Tree View 6 Select the device to configure by clicking on it 7 Select System tab to bring up the Enable ProView Features field Before a device can be configured the ProView feature must be enabled CONFIGURATION UTILITY 8 Click the Enable ProView Features radio button and click Apply to configure the device TY Advantech EKI Device Configuration Utility an EE EN roca File View Management Tools Help dale Ja B amp EKI Device Summary System SNMP PoE S ProView Switch 2 S EKI 5728P Firmware Version 1 02 5 EKI 5728P Eth 1 192 168 1 10 Device Name Favorites 3 8t Serial Ports EKI 5728P s a System Serial Ports B Virtual Com Ports Device Description Gigabit Ethernet Indastrial PoE ProView Switch Iv Enable ProView Feaures Modbus TCP Host Idle Time s I0 LLDP Enable LLDP Fea
56. hars ASCII 0x0211 30530 Product Name Info Number Y Y Y xxxxx Word 0 Hi byte Y Word 0 Lo byte Y Word 1 Hi byte Y Word 1 Lo byte Word 2 Hi byte x Word 2 Lo byte x Word 3 Hi byte x Word 3 Lo byte x Word 4 Hi byte x Word 4 Hi byte O IP Address 2 words 32 bits HEX 0x0400 31025 IP Address Ex IP 192 168 1 1 Word 0 Hi byte OxCO Word 0 Lo byte 0xA8 Word 1 Hi byte 0x01 Word 1 Lo byte 0x01 Port Info Port Status 1 word 16 bits HEX 0x1000 34097 Port Status 0x101F 34128 0x0000 Link down 0x0001 Link up OxFFFF No port Port 1 Status 1 word 16 bits HEX 0x1000 34097 Port 2 Status 1 word 16 bits HEX 0x1001 34098 Port 3 Status 1 word 16 bits HEX 0x1002 34099 Port 4 Status 1 word 16 bits HEX 0x1003 34100 Port 5 Status 1 word 16 bits HEX 0x1004 34101 Port 6 Status 1 word 16 bits HEX 0x1005 34102 Port 7 Status 1 word 16 bits HEX 0x1006 34103 Port 8 Status 1 word 16 bits HEX 0x1007 34104 Port 9 Status 1 word 16 bits HEX 0x1008 34105 Port 10 Sta 1 word 16 bits HEX 0x1009 34106 tus Port 11 Sta 1 word 16 bits HEX 0x100A 34107 tus Port 12 Sta 1 word 16 bits HEX 0x100B 34108 tus 73 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3X tion Hex Port Info Port 13 Sta
57. ied and authorized to do so Do not block air ventilation holes Electromagnetic Interference EMI affects the transmission performance of a device By properly grounding the device to earth ground through a drain wire you can setup the best possible noise immunity and emissions Connection to Grounding Point O Drain Wire with Lug Figure 2 13 Grounding Connection 44 SWITCH INSTALLATION By connecting the ground terminal by drain wire to earth ground the switch and chassis can be ground ensure there is no voltage difference between the power supply s negative output Before applying power to the grounded switch it is advisable to use a volt meter to terminal and the grounding point on the switch 2 6 4 Wiring a Relay Contact The following section details the wiring of the relay output The terminal block on the EKI 5000 Series is wired and then installed onto the terminal receptor located on the EKI 5000 Series DC 12 48V PWR2 1A 24V PWR1 E 5 V2 V2 LV vi vit P Fail Figure 2 14 Terminal Receptor Relay Contact The terminal receptor includes a total of six pins two for PWR1 two for PWR2 and two for a fault circuit 2 6 5 Wiring the Power Inputs Do not disconnect modules or cabling unless the power is first switched off The device only supports the voltage outlined in the type plate Do not u
58. ion the following guidelines before wiring the device e The Terminal Block CN1 is suitable for 12 24 AWG 3 31 0 205 mm Torque value 7 Ib in e The cross sectional area of the earthing conductors shall be at least 3 31 mm e Calculate the maximum possible current for each power and common wire Make sure the power draw is within limits of local electrical code regulations e For best practices route wiring for power and devices on separate paths e Do not bundle together wiring with similar electrical characteristics 43 SWITCH INSTALLATION e Make sure to separate input and output wiring e Label all wiring and cabling to the various devices for more effective management and servicing Routing communications and power wiring through the same conduit may cause signal interference To avoid interference and signal degradation route power and communications wires through separate conduits 2 6 3 Grounding the Device Do not disconnect modules or cabling unless the power is first switched off A The device only supports the voltage outlined in the type plate Do not use any other power components except those specifically designated for the switch device Before connecting the device properly ground the device Lack of a proper ground A ing setup may result in a safety risk and could be hazardous Do not service equipment or cables during periods of lightning activity Do not service any components unless qualif
59. its HEX 0x181E 36175 Voltage Port 32 PoE 1 word 16 bits HEX 0x181F 36176 Voltage PoE Current 1 word 16 bits HEX 0x1820 36177 0x183F 36208 2 PoE Current mA Ex poe current 13 Received MODBUS response 0x000D Port 1 PoE 1 word 16 bits HEX 0x1820 36177 Current Port 2 PoE 1 word 16 bits HEX 0x1821 36178 Current Port 3 PoE 1 word 16 bits HEX 0x1822 36179 Current 83 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 4 PoE 1 word 16 bits HEX 0x1823 36180 Current Port 5 PoE 1 word 16 bits HEX 0x1824 36181 Current Port 6 PoE 1 word 16 bits HEX 0x1825 36182 Current Port 7 PoE 1 word 16 bits HEX 0x1826 36183 Current Port 8 PoE 1 word 16 bits HEX 0x1827 36184 Current Port 9 PoE 1 word 16 bits HEX 0x1828 36185 Current Port 10 PoE 1 word 16 bits HEX 0x1829 36186 Current Port 11 PoE 1 word 16 bits HEX 0x182A 36187 Current Port 12 PoE 1 word 16 bits HEX 0x182B 36188 Current Port 13 PoE 1 word 16 bits HEX 0x182C 36189 Current Port 14 PoE 1 word 16 bits HEX 0x182D 36190 Current Port 15 PoE 1 word 16 bits HEX 0x182E 36191 Current Port 16 PoE 1 word 16 bits HEX 0x182F 36192 Current Port 17 PoE 1 word 16 bits HEX 0x1830 36193 Current Port 18 PoE 1 word 16 bits HEX
60. k a desired device to display the settings menu 2 Select Add to Favorite TE Advantech EKI Device Configuration Utility vi 71 al File View Management Tools Help ip alaala an 8 3 ef EKI Device Summary System SNMP Eb ProView Switch Basic Information Eg ED Tme T EKI 5725 a EKI 5725 eb Serial Di Evie XY Favorites F Refresh Dat T Serial Ports cres E System Reset Device Virtual eae 192 168 1 1 2552552550 0 0 0 0 Update Firmware EKI 5725 EKI 5725 Ethemet Port 1 MAC 00 23 79 00 23 79 Static IP Address 192 168 1 1 Tuesday October 28 2014 9 50 42 AM B Figure 4 6 Adding a Switch to Favorites In the event that there are existing groups you can select the specific favorite group to include the selected device MANAGING SWITCH Adding an IP Address 1 From the Tool Bar click the Add IP Address to Favorite button 2 Enter an IP address 3 Click OK to add the IP address into the favorites list r Advantech EKI Device Configuration Utility v1 71 SIE Xj File View Management Tools Help ef EKI Device ProView Switch El EKI 5725 EKI 5725 H P Serial Device Server a Favorites ETE Serial Ports t System Serial Ports Virtual Com Ports Inpu
61. le View Management Tools Help 4 3 9 aa B EKI Device Summary System SNMP PE ProView Switch G EKI S728P Refresh amp EKI S728P Ed Eth 1 192 168 1 10 Enable Port Voltage V Current nA Power QW Temperature CC Favorites Port 1 0 zi Serial Ports Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 SA System Serial Ports B Virtual Com Ports oo ooo oo oo ooo sd oo VA Us tag tag teg LBB OOOO Tuesday January 13 2015 4 24 41 PM e x i m R Figure 4 12 Setting Modbus TCP Idle Time 4 2 Modbus TCP Mapping The data map addresses of Advantech switches shown in the following table start from Modbus address 30001 for function code 4 MANAGING SWITCH In the given example the address offset 0x1000 hex equals Modbus address 34097 while the address offset 0x1100 hex equals Modbus address 34353 The information given by the Advantech is shown in hex mode 4 2 1 Modbus TCP Mapping Table Table 4 1 Modbus TCP Mapping Table Catelog Name Data Type Address Address Description Offset 3X Hex System Vendor ID 1 word 16 bits HEX 0x0000 30001 Vendor ID 0x13FE Info Ox 13FE Unit ID 1 word 16 bits HEX 0x0001 30002 Unit ID OxFF OxFF Product 1 word 16 bits HEX 0x0002 30003 Product Code Code 71 Table 4 1 Modbus TCP Mapping Table Continu
62. lost contact after retry for 3 times Unsigned hardware installation I V Automatic answer for unsigned hardware installation Cancel Apply Tuesday October 28 2014 9 39 39 AM a 3 Figure 3 8 View Settings Device Manager Table 3 3 Utility Settings Device Manager Item Description Device Manager Tree View Grouping Click the drop down menu to enable or disable grouping Show Empty Device Type Check the checkbox to show empty device type node or not Node Expand New Appended Check the checkbox to expand a new appended device node or not Device Node Device Auto Detection After utility ready start auto Enter a value to specify the time to auto detection time 1 means detection after X second disable auto detection Auto detect devices every Enter a value to specify the time to auto detect devices X second m 55 CONFIGURATION UTILITY Table 3 3 Utility Settings Device Manager Continued Item Description Check device alive every X Enter a value to specify the time to check device alive second Mark device as lost contact Enter a value to specify the time to mark device as lost contact after retry for X times Unsigned Hardware Installation Automatic answer for Check the checkbox to enable or disable answer automatically for unsigned hardware unsigned hardware installation installatio
63. minal block Connect cabling for power and alarm wiring The following view applies to EKI 5728 EKI 5728l EKI 5729F EKI 5729Fl EKI 5528 EKI 5528l EKI 5524SS EKI 5524SSI EKI 5524MM EKI 5524MMI EKI 5524SS ST EKI 5524SSI ST EKI 5524MM ST and EKI 5524MMI ST DC 12 48V PW T PWR1 V2 V2 LVJ vi Vit P Fail S eee EEE EEEE Figure 1 22 Top View Table 1 25 Top View No Item Description 1 Terminal block Connect cabling for power and alarm wiring PRODUCT OVERVIEW The following view applies to EKI 5526 EKI 5526l EKI 5629C EKI 5629Cl EKI 5626C and EKI 5626Cl ecoc 0 0 00000000 DC12 48V PWR2 1AQ24V PWR1 V2 V2 LV Vie Vir E Figure 1 23 Top View Table 1 26 Top View No Item Description 1 Terminal block Connect cabling for power and alarm wiring The following view applies to EKI 5726 EKI 57261 EKI 5726l and EKI 5726FI e 2e20 0020200000800080 ee2eo ea2e2eeeeeeeeee 0 e eeoo oce0006000000 DC 12 48V PWR2 1A 24V PWR1 eoo eoo eee 1 eoo V2 V2 LVJ vi Vir 2 ee en eco e2e2e2e20e02080200000000 e2e2e 20000000080000 eececc 0 0e 000000000 eeoe0 0 0 00000000009 eece0 0 0 000000000909 eoec 00000000000009 eeoeo 0c0 0e00000000009 Figure 1 24 Top View Table 1 27 Top View No Item Description 1 Terminal block Connect cabling for power and alarm wiring m 29 PRODUCT OVERVIEW The following view a
64. n OK Click OK to save and exit the utility setting Cancel Click Cancel to discard the changes Apply Click Apply to save the utility setting 3 5 2 Management Menu Table 3 4 Management Item Description Configuration Wizard Start the software wizard setup assistant to leads you through the VCOM configuration process for device server product Clear Device List and Clear all device list and re search devices Search Again Search Again Re search devices Add IP Address to Favorite Add one device to Favorites Search for a Range of IP Add a group of device to Favorites Addresses Manual Direct Mapping Click to add a target by selecting a Device Type and inputting the IP Virtual COM Port address physically connecting the serial device server to the network is not required 3 5 3 Help Menu Table 3 5 Help Check Utility Update Select to update configuration utility About Select to show the information about the configuration utility 56 CONFIGURATION UTILITY 3 6 Tool Bar The tool bar is a list of shortcuts for the most frequently used menu functions Icons are pro vided for each function By clicking on the icon the most frequently used functions can be accessed Table 3 6 Tool Bar Item Description 9 23 Utility Settings Refer to Utility Settings on page 54 Configuration Wizard Refer to Management Menu on page 56 Clear Device Lis
65. nfiguring a Static IP Setting MANAGING SWITCH 4 1 2 Discovering Switches Auto Search Only devices within the same network domain can be listed through the search function Once a device is listed the features and configuration details are accessible by clicking on the device name X Advantech EKI Device Configuration Utility v 71 File View Management Tools Help ys EKI Device E148 ProView Switch 5 8 ERES Ej EKI 5725 og Eth 1 192 168 1 1 ef Serial Device Server A Favorites E Serial Ports System Serial Ports sq Virtual Com Ports Tuesday October 28 2014 9 46 11 AM il S Figure 4 3 Auto Searching Screen MANAGING SWITCH To search for a device 1 From the Tool Bar click the Search Again lt button TE Advantech EKI Device Configuration Utility vi pem Fille View Management Tools Help ra fe Alea a9 Lea B EKI Device z p ProView Switch Search Again EKI 5725 EKI 5725 Eth 1 192 168 1 1 E Serial Device Server F TS Serial Ports ts System Serial Ports Virtual Com Ports Tuesday October 28 2014 9 47 07 AM N Figure 4 4 Selecting Search Again Access to the utility s full function list reguires administrator privileges Clearing Device List and Search Again The search list can be cleared for a new search reguest by
66. nstallShield Wizard 1 of 4 5 The Software License Agreement displays press Agree to continue or Cancel to stop the installation License Agreement Nullsoft Install System v2 46 Advantech EKI Device Configuration Utility Setup EIER YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS Opening and using the enclosed software for any purpose indicates your acceptance of the terms and conditions of this License Agreement If you do not agree with the terms and conditions of this license agreement you should return all software documentation and copy protection keys for a refund Restocking fees may apply Advantech Automation Corporation provides this program and licenses for its use in the United States Puerto Rico or internationally You assume the responsibility For the selection of the program to achieve your intended results and for the installation use and results obtained from this program LICENSE Grant of License You are granted a personal license to use this program under the terms stated in this Agreement You may 1 Tnersll and nea the rroorsam on 3 cinala m If you accept the terms of the agreement click I Agree to continue You must accept the agreement to install Advantech EKI Device Configuration Utility Figure 3 3 InstallShield Wizard 2 of 4 51 6 CONFIGURATION UTILITY The InstallShield continues and a status screen displays The default installation path is C Program Fil
67. o B2 This is a Class 1 Laser LED product To avoid causing serious damage to your eyes do not stare directly into the Laser Beam SWITCH INSTALLATION 2 4 1 Installing SFP Modules To connect the fiber transceiver and LC cable use the following guidelines 1 Remove the dust plug from the fiber optic slot chosen for the SFP transceiver Figure 2 6 Removing the Dust Plug from an SFP Slot Do not remove the dust plug from the SFP slot if you are not installing the trans y ceiver at this time The dust plug protects hardware from dust contamination Position the SFP transceiver with the handle on top see the following figure Locate the triangular marking in the slot and align it with the bottom of the transceiver Insert the SFP transceiver into the slot until it clicks into place B e Bd Make sure the module is seated correctly before sliding the module into the slot A click sounds when it is locked in place Handle Figure 2 7 Installing an SFP Transceiver vw If you are attaching fiber optic cables to the transceiver continue with the following step Otherwise repeat the previous steps to install the remaining SFP transceivers in the device 40 SWITCH INSTALLATION 6 Remove the protective plug from the SFP transceiver Do not remove the dust plug from the transceiver if you are not installing the fiber optic cable at this time The dust plug protects hardware from dust contamination
68. ols Help 1 dae E4 EKI Device Summary System SNMP PoE S P ProView Switch B EKI 5728P Firmware Version 1 02 amp EKI 5728P Eth 1 192 168 1 10 Device Name R Favorites B Serial Ports EK1 5728P sl System Serial Ports B Virtual Com Ports Device Dec on Gigabit Ethernet Indastrial PoE ProView Switch Iv Enable ProView Feaures Modbus TCP Host Idle Time s I0 LLDP Enable LLDP Feature LLDP Interval 0 n IEKI 5728P 8 Ethernet Port E EN LU i Tuesday January 13 2015 4 04 10 PM ij ao Figure 4 10 Setting Modbus TCP Idle Time The Modbus TCP idle time is now set MANAGING SWITCH Setting LLDP 1 2 3 4 Select the device to configure by clicking on it In the Configuration Area select the System tab Under LLDP check Enable LLDP Feature to enable the LLDP feature This feature is used by the device to advertise its identity capabilities and neighbors throughout the network Enter a variable representing the idle time for sending of LLDP information Setting Networks Parameters For setting networks parameters see Configuring Network Settings on page 59 Setting SNMP 1 2 69 Select the device to configure by clicking on it In the Configuration Area select SNMP tab The Basic and Community settings are listed for configuration In the SNMP Basic Settings selection enter a contact and location in the respective fields In the
69. ottom View Table 1 32 Bottom View No Item Description 1 Ground terminal Screw terminal used to ground chassis The following view applies to EKI 5725FP EKI 5725FPI EKI 5624P EKI 5624PI EKI 5729P and EKI 5729PI Figure 1 30 Bottom View PRODUCT OVERVIEW 1 4 Packing List The product package you have received should contain the following items If any of them are not included or damaged please contact your local vendor for support e 1x Industrial Ethernet Switch e 1x Wall mounting Bracket e 1x DIN Rail mounting Bracket and Screws e 1x EKI Device Configuration Utility CD ROM e 1x Startup Manual 33 Switch Installation Chapter 2 SWITCH INSTALLATION 2 1 Installation Guidelines The following guidelines are provided to optimize the device performance Review the guidelines before installing the device e Make sure cabling is away from sources of electrical noise Radios power lines and flu orescent lighting fixtures can interference with the device performance e Make sure the cabling is positioned away from equipment that can damage the cables e Operating environment is within the ranges listed range see Specifications on page 2 e Relative humidity around the switch does not exceed 95 percent noncondensing e Altitude at the installation site is not higher than 10 000 feet e n 10 100 and 10 100 1000 fixed port devices the cable length from the switch to con nected device
70. pplies to EKI 5725FP and EKI 5725FPI VitV1 DC24 48V 1 e e o e o PWR2 P Fail PWR1 e e o Figure 1 25 Top View Table 1 28 Top View No Item Description 1 Terminal block Connect cabling for power and alarm wiring The following view applies to EKI 5624P EKI 5624PI EKI 5729P and EKI 5729PI Vit V1 DC12 24V 1 eee PWR2 P Fail PWR1 eee e e e Figure 1 26 Top View Table 1 29 Top View No Item Description 1 Terminal block Connect cabling for power and alarm wiring PRODUCT OVERVIEW 1 3 4 Bottom View The following view applies to EKI 5525S EKI 5525SI EKI 5525M EKI 5525MI EKI 5525S ST EKI 5525SI ST EKI 5525M ST EKI 5525MI ST EKI 5525 EKI 5525l EKI 5725 and EKI 5725l Figure 1 27 Bottom View Table 1 30 Bottom View No Item Description 1 Ground terminal Screw terminal used to ground chassis The following view applies to EKI 5728 EKI 5728l EKI 5729F EKI 5729FI EKI 5528 EKI 5528l EKI 5524SS EKI 5524SSI EKI 5524MM EKI 5524MMI EKI 5524SS ST EKI 5524SSI ST EKI 5524MM ST and EKI 5524MMI ST Figure 1 28 Bottom View Table 1 31 Bottom View No Item Description 1 Ground terminal Screw terminal used to ground chassis PRODUCT OVERVIEW The following view applies to EKI 5526 EKI 5526l EKI 5629C EKI 5629Cl EKI 5626C EKI 5626Cl EKI 5726 EKI 57261 EKI 5726F and EKI 5726FI Figure 1 29 B
71. rts EKI 5524MM EKI 5524MMI Two SC multi mode ports The following view applies to EKI 5524SS ST EKI 5524SSI ST EKI 5524MM ST and EKI 5524MMI ST Lovani e UI liovanis U J Figure 1 7 Front View Table 1 10 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 2 ETH port Four RJ45 ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 3 LNK ACT LED Link activity LED 14 PRODUCT OVERVIEW 15 Table 1 10 Front View Continued No Item Description 4 Speed LED Fast Ethernet e Amber 100M e Off 10M 5 ST port EKI 5524SS ST EKI 5524SSI ST Two ST single mode ports EKI 5524MM ST EKI 5524MMI ST Two ST multi mode ports The following view applies to EKI 5526 EKI 5526l EKI 5726 and EKI 5726l Table 1 11 Front View Ls Figure 1 8 Front View No Item Description 1 System LED panel See System LED Panel on page 22 for further details 2 ETH port EKI 5526 EK1 5526l Sixteen 10 100BaseT X ports EKI 5726 EKI 5726l Sixteen 10 100 1000BaseT X ports Port numbers in black are designated for port based Quality of Ser vice QoS functionality 3 LNK ACT LED Link activity LED PRODUCT OVE
72. s TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Packet Tx Packets 4 words 64 bits HEX 0x2000 38193 Tx Packets Info Counter 0x207C 38317 Ex port 1 Tx Packet Amount 11223344 Received MODBUS response 0xAB4130 Word 0 0x0000 Word 1 0x0000 Word 2 0x00AB Word 3 0x4130 Port 1 Tx 4words 64 bits HEX 0x2000 38193 Packets Port 2 Tx 4 words 64 bits HEX 0x2004 38197 Packets Port 3 Tx 4words 64 bits HEX 0x2008 38201 Packets Port 4 Tx 4words 64 bits HEX 0x200C 38205 Packets Port 5 Tx 4words 64 bits HEX 0x2010 38209 Packets Port 6 Tx 4 words 64 bits HEX 0x2014 38213 Packets Port 7 Tx 4words 64 bits HEX 0x2018 38217 Packets Port 8 Tx 4 words 64 bits HEX 0x201C 38221 Packets Port 9 Tx 4 words 64 bits HEX 0x2020 38225 Packets Port 10 Tx 4 words 64 bits HEX 0x2024 38229 Packets Port 11 Tx 4 words 64 bits HEX 0x2028 38233 Packets Port 12 Tx 4 words 64 bits HEX 0x202C 38237 Packets Port 13 Tx 4 words 64 bits HEX 0x2030 38241 Packets Port 14 Tx 4 words 64 bits HEX 0x2034 38245 Packets Port 15 Tx 4 words 64 bits HEX 0x2038 38249 Packets 89 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3X tion Hex Packet Port 16 Tx 4 words
73. s can not exceed 100 meters 328 feet e Make sure airflow around the switch and respective vents is unrestricted Without proper airflow the switch can overheat To prevent performance degredation and dam age to the switch make sure there is clerance at the top and bottom and around the exhaust vents 2 1 1 Connecting Hardware In this instruction it will explain how to find a proper location for your Modbus Gateways and how to connect to the network hock up the power cable and connect to the EKI 5000 Series 2 2 Verifying Switch Operation 35 Before installing the device in a rack or on a wall power on the switch to verify that the switch passes the power on self test POST To connect the cabling to the power source see Power Supply Installation on page 43 At startup POST the System LED blinks green while the remaining LEDs are a solidy green Once the switch passes POST self test the System LED turns green The other LEDs turn off and return to their operating status If the switch fails POST the System LED switches to an amber state After a successful self test power down the switch and disconnect the power cabling The switch is now ready for installation on its final location SWITCH INSTALLATION 2 3 Installing the Switch 2 3 1 DIN Rail Mounting The DIN rail mount option is the quickest installation option Additionally it optimizes the use of rail space The metal DIN rail kit is secured to the rear
74. se any other power components except those specifically designated for the switch device POWER DOWN AND DISCONNECT THE POWER CORD BEFORE SERVICING OR WIRING THE SWITCH There are two power inputs for normal and redundant power configurations The power input 2 is used for wiring a redundant power configuration See the following for terminal block connector views DC 12 48V PWR2 1A 24V PWR1 ei a V2 V2 LV Vi vit P Fail Figure 2 15 Terminal Receptor Power Input Contacts 45 SWITCH INSTALLATION To wire the power inputs Make sure the power is not connected to the switch or the power converter before proceed ing 1 Loosen the screws securing terminal block to the terminal block receptor 2 Remove the terminal block from the switch Figure 2 16 Removing a Terminal Block 3 Insert a small flat bladed screwdriver in the V1 V1 wire clamp screws and loosen the Screws 4 Insert the negative positive DC wires into the V V terminals of PW1 If setting up power redundancy connect PW2 in the same manner 5 Tighten the wire clamp screws to secure the DC wires in place Loosening m Securing C Wire clamp KO Wire clamp Cx Screws 5 Screws vibe Figure 2 17 Installing DC Wires in a Terminal Block 6 Align the terminal block over the terminal block receptor on the switch 7 Insert the terminal block and press it in un
75. t 23 Rx 4 words 64 bits HEX 0x2158 38537 Packets Port 24 Rx 4 words 64 bits HEX 0x215C 38541 Packets Port 25 Rx 4 words 64 bits HEX 0x2160 38545 Packets Port 26 Rx 4 words 64 bits HEX 0x2164 38549 Packets Port 27 Rx 4 words 64 bits HEX 0x2168 38553 Packets Port 28 Rx 4words 64 bits HEX 0x216C 38557 Packets Port 29 Rx 4 words 64 bits HEX 0x2170 38561 Packets Port 30 Rx 4words 64 bits HEX 0x2174 38565 Packets Port 31 Rx 4 words 64 bits HEX 0x2178 38569 Packets Port 32 Rx 4 words 64 bits HEX 0x217C 38573 Packets 92 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Packet Tx Error 2 words 32 bits HEX 0x2200 38705 Tx Error Packets Info Packets 0x223E 38767 Ex port 1 Tx Packet gounter Amount 11223344 Received MODBUS response 0xAB4130 Word 0 0x00AB Word 1 0x4130 Port 1 Tx 2 words 32 bits HEX 0x2200 38705 Error Pack ets Port 2 Tx 2 words 32 bits HEX 0x2202 38707 Error Pack ets Port 3 Tx 2 words 32 bits HEX 0x2204 38709 Error Pack ets Port 4 Tx 2 words 32 bits HEX 0x2206 38711 Error Pack ets Port 5 Tx 2 words 32 bits HEX 0x2208 38713 Error Pack ets Port 6 Tx 2 words 32 bits HEX 0x220A 38715 Error Pack ets Port 7 Tx 2 words 32 bits HEX 0x220C 38717 Error Pack
76. t IP address NM m EER oes Tuesday October 28 2014 95226AM DD Figure 4 7 Add Favorite In the event that there are existing groups you can select the specific favorite group to include the selected IP address MANAGING SWITCH Adding an IP Address Range 1 From the Tool Bar click the Search for a Range of IP Addresses amp button 2 Enter a starting and ending IP address range 3 Click OK to add the range into the favorites list 7 TE Advantech EKI Device Configuration Utility v1 71 o B P4 File View Management Tools Help Ad aas Ef EKI Device ProView Switch EKI 5725 t EKI 5725 amp Serial Device Server j n Favorites Serial Ports t System Serial Ports Virtual Com Ports Please input a vaild IP range Start IP Address OK End IP Address i Figure 4 8 Add Favorite In the event that there are existing groups you can select the specific favorite group to include the selected IP address range MANAGING SWITCH 4 1 4 Configuring the System Changing Device Name 1 Select the device to configure by clicking on it 2 In the Configuration Area select System tab 3 Locate the Device Name field and enter a device name 4 Click Apply to configure the device M aavantech ER Device COMRGUTGHON Utility vii NN NN ON sc S File
77. t and Refer to Management Menu on page 56 Search Again Auto Search Refer to Management Menu on page 56 Search Again Add IP Address to Refer to Management Menu on page 56 Favorite Search for a Range Refer to Management Menu on page 56 of IP Addresses Manual Direct Refer to Management Menu on page 56 Mapping Virtual COM Port 3 7 TreeView The TreeView configuration area displays the selected device s configurable settings From this area you can directly group devices in the favorite s list See Utility Menu Map on page 53 3 8 Information Panel e le KIE e The Information Panel area displays the selected device s related information See Utility Menu Map on page 53 3 9 Status Bar The Status Bar area displays the current time See Utility Menu Map on page 53 3 10 Configuration Area The Configuration Area displays correlating information from selected menu items within the TreeView area See Utility Menu Map on page 53 57 Managing Switch Chapter 4 MANAGING SWITCH 4 1 Discovering Switches 4 1 1 First Time Installation Enabling ProView Function See Enabling ProView Function on page 49 for further information Configuring Network Settings EKI Device Configuration Utility provides two ways to configure network settings DHCP Auto IP Settings or Static Settings DHCP Auto IP Settings 1 Select Ethernet under the desired device
78. til it is flush with the terminal block receptor 46 SWITCH INSTALLATION 8 Tighten the screws on the terminal block to secure it to the terminal block receptor If there is no gap between the terminal block and the terminal receptor the terminal block is seated correctly Figure 2 18 Securing a Terminal Block to a Receptor ad 47 Configuration Utility etos CONFIGURATION UTILITY 3 1 Overview 3 2 49 This section describes the installation procedures for the Advantech EKI Device Configura tion Utility The Configuration Utility is the software tool for setting up and monitoring the EKI 5000 Series Enabling ProView Function The configuration of a ProView switch can be accessed by using EKI Device Configuration Utility To install the software utility see Installing the Configuration Utility on page 50 The ProView features for the device must be enabled The following guidelines allow you to enable and disable the ProView features Microsoft Windows 7 is used as a reference for the development of the following guidelines The following navigation references may differ depending on your oper ating system To fully access all the available options in the Configuration Utility administrative privileges are required Without the use of administrative privileges some functions of the Configuration Utility are not accessible Before continuing further any devices selected for confi
79. ture LLDP Interval PO EK1 5728P Ethernet Port Tuesday January 13 2015 4 04 10 PM Figure 3 1 Enabling ProView Features The ProView function is enabled and the switch can be configured 3 3 Installing the Configuration Utility Microsoft NET Framework version 2 0 or greater is required for this application 1 Insert the Advantech EKI Device Configuration Utility CD ROM into the CD ROM drive whereas E is the drive name of your CD ROM on the host PC 2 Use Windows explorer or the Windows Run command to execute the setup program the path for the setup program on the CD ROM is as follows EAEKI Device Configuration Utility v1 70 exe 3 Ifthere is an existing COM port mapping utility on the host PC remove it at this time A system reboot may be necessary before continuing the installation CONFIGURATION UTILITY 4 Once the InstallShield Wizard screen displays click Next to proceed with the installa tion Nullsoft Install System v2 46 4 amp Advantech EKI Device Configuration Utility Setup IE Jt Welcome to the Advantech EKI Device Configuration Utility Setup Wizard This wizard will quide you through the installation of Advantech EKI Device Configuration U It is recommended that you close all other applications before starting Setup This will make it possible to update relevant system files without having to reboot your computer Click Next to continue Figure 3 2 I
80. x1117 34376 Speed Port 25 1 word 16 bits HEX 0x1118 34377 Speed Port 26 1 word 16 bits HEX 0x1119 34378 Speed Port 27 1 word 16 bits HEX 0x111A 34379 Speed Port 28 1 word 16 bits HEX 0x111B 34380 Speed Port 29 1 word 16 bits HEX 0x111C 34381 Speed Port 30 1 word 16 bits HEX 0x111D 34382 Speed Port 31 1 word 16 bits HEX Ox111E 34383 Speed Port 32 1 word 16 bits HEX Ox111F 34384 Speed Flow Control 1 word 16 bits HEX 0x1200 34609 Flow Control 0x0001 On OxFFFF No port Port 1 Flow 1 word 16 bits HEX 0x1200 34609 Control Port 2 Flow 1 word 16 bits HEX 0x1201 34610 Control Port 3 Flow 1 word 16 bits HEX 0x1202 34611 Control Port 4 Flow 1 word 16 bits HEX 0x1203 34612 Control Port5 Flow 1 word 16 bits HEX 0x1204 34613 Control 76 MANAGING SWITCH Table 4 1 Modbus TCP Mapping Table Continued Catelog Data Type Inter Address Address Description preta Offset 3x tion Hex Port Info Port 6 Flow 1 word 16 bits HEX 0x1205 34614 Control Port 7 Flow 1 word 16 bits HEX 0x1206 34615 Control Port 8 Flow 1 word 16 bits HEX 0x1207 34616 Control Port 9 Flow 1 word 16 bits HEX 0x1208 34617 Control Port 10 Flow 1 word 16 bits HEX 0x1209 34618 Control Port 11 Flow 1 word 16 bits HEX 0x120A 34619 Control Port 12 Flow 1 word 16 bits HEX 0x120B 34620 Control Port 13 Flow 1 word 16 bits HEX 0x120C 34621 Control Port 14 Flow 1 word 16