1. WJ 4017777 a UT lt gt HIT AT Kas om s gt b 5 5 LL 4 4 4 Pi I HII y VV Blast IR Industry standard theatrical and rental LED wash fixture with intelligent white light ola COLOR KINETICS IVV Blast TR Industry standard theatrical and rental LED wash fixture with intelligent white light iW Blast TR is a rugged intelligent white LED fixture designed specifically to withstand taxing stage set and touring environments This rental friendly fixture offers ease of installation and control along with the ability to produce high quality white light with a temperature range of 2700 K to 6500 K It features a standard 4 pin XLR connector an innovative elastomeric sleeve that protects the fixture during rough handling and a pivoting bezel for easy exchange of lenses An industrial grade hinge affords quick and reliable fixture aiming and locking The mounting base easily accommodates truss clamps and other mounting and positioning options Designed with live entertainment in mind iW Blast TR is the ideal intelligent white LED fixture for demanding temporary and touring environments e Wide range of color temperature and brightness Channels of warm white and cool white LEDs produce color temperatures ranging from 2700 K to 6500 K You can adjust fixture brightness while varying or maintaining constant color temperature e Pivoting bezel and exchangeable lenses The pivoting b
2. 30 20 50 30 20 50 30 20 0 19 1 19 1 19 1 19 1 16 1 16 1 16 1 00 1 11 1 11 1 11 1 06 1 06 1 06 1 02 1 02 1 02 1 00 16 1 14 1 12 1 11 1 13 1 12 1 10 98 1 08 1 07 1 06 1 04 1 03 1 03 1 01 1 00 1 00 98 13 1 10 1 07 1 05 1 11 1 08 1 06 97 1 05 1 03 1 02 1 02 1 01 1 00 1 00 99 98 96 10 1 06 1 03 1 01 1 08 1 05 1 02 95 1 03 1 00 99 1 00 99 97 98 97 96 95 08 1 03 1 00 98 1 06 1 02 99 94 1 00 98 96 99 97 95 97 95 94 93 06 1 01 98 95 1 04 1 00 97 92 99 96 94 97 95 93 96 94 93 92 04 99 95 93 1 03 98 95 91 97 94 92 96 93 92 95 93 91 90 02 97 94 91 1 01 96 93 90 95 93 91 94 92 90 94 92 90 89 00 95 92 90 99 95 92 89 94 91 90 93 91 89 92 90 89 88 99 94 91 89 98 93 91 88 93 90 88 92 90 88 91 89 88 87 97 93 90 88 97 92 89 87 92 89 87 91 89 87 91 88 87 86 RCC Ceiling reflectance percentage RW Wall reflectance percentage RCR Room cavity ratio IW Blast TR Product Guide 3 Specifications Due to continuous improvements and innovations specifications may change without notice Item Output Electrical Control Physical Certification and Safety Lumen measurement complies with IES LM 79 08 testing FE CE procedures Specification Beam Angle Lumens Color Temperaturet Efficacy Im W Mixing Distance CRI Lumen Maintenancet Input Voltage Power Consumption Interface Control System Dimensions
3. 73 69 66 72 69 66 65 81 73 68 65 80 72 68 64 71 67 64 71 67 64 70 67 64 63 RCC Ceiling reflectance percentage RW Wall reflectance percentage RCR Room cavity ratio Polar Candela Distribution Cd 0 6 864 13 728 20 593 27 457 34 321 41 185 VA 0 10 M 0H Zonal Lumen Zone 0 30 1 590 5 0 40 1 623 5 0 60 1 674 1 60 90 5 2 0 90 1 679 3 90 180 0 0 180 1 679 3 20 94 7 96 7 99 7 0 3 100 0 100 Total Efficiency 100 For lux multiply fc by 10 7 30 M 90 H Lumens Lamp Luminaire 94 7 96 7 99 7 0 3 100 0 100 90 80 70 60 50 22 5 44 67 5 90 O 40724 40724 40724 40724 40724 5 18090 1846118629 18569 17567 746 205 42 25 42 0 15 573 25 203 35 35 45 35 55 35 65 25 75 0 85 0 90 0 743 813 810 207 207 205 44 47 47 32 27 25 37 30 42 7 2 5 0 0 0 0 0 0 0 0 0 O O O GI Illuminance at Distance 4 3 ft 8 7 ft 13 ft 17 3 ft 21 7 ft 26 ft Center Beam FC 2 169 fe 542 fc 241 fc 136 fc 87 fc 60 fc 202 ft 61 6 m 1 fc maximum distance Beam Width 7 ft dit 1 3f 1 4ft 2 0ft 2 1 ft 2 7 ft 2 8 ft 34 ft 3 5 ft 40ft 4 2ft Coefficients Of Utilization Zonal Cavity Method RCC RW RCR 0 O NOOIAWND lt 10 M Vert Spread 8 8 BE Horiz Spread 9 1 Effective Floor Cavity Reflectance 20 80 70 50 30 10 0 70 50 30 0 70 50 30 0 50
4. bezel forward to access the lens 4 Remove the installed lens 5 Clean both sides of the lens using a mild non abrasive cleaner Handle the lens by the gasket making sure not to touch or soil either surface Place the lens in the fixture housing making sure the gasket around the lens is properly fitted Install the frosted 23 glass lens smooth side up 6 Close the bezel tighten the lock down screws and replace the protective cover IW Blast TR Product Guide 7 Attach Safety Cable Optional Each iW Blast TR fixture is designed for use with a safety cable to tether it to a secure anchor point When dictated by local or state code or advised by a structural engineer attach a safety cable to the bracket on the back of the fixture using a standard carabiner clip Attach the safety cable to the mounting surface using a method that follows the code or engineer s requirements Address and Configuring For installations in which you want to change the brightness and color temperature of all fixtures in unison no fixture addressing or configuration is necessary To support dynamic effects that automatically modify brightness and color temperature on individual fixtures you must address and configure iW Blast TR Powercore fixtures as you would any color changing RGB fixture iW Blast TR Powercore fixtures use DMX addresses to communicate with controllers The number of DMX addresses each iW Blast TR Powercore fixture requires dep
5. by LED source manufacturers Calculations for white light LED fixtures are based on measurements that comply with IES LM 80 08 testing procedures Refer to www philipscolorkinetics com support appnotes lm 80 08 pdf for more information CHROMACORE CKTECHNOLOGY 4 IW Blast TR OPTIBIN CKTECHNOLOGY Product Guide 110 10 Beam Angle 23 Beam Angle 110 Rotation In addition to the PDS 750 TRX power data supply City Theatrical Inc offers a line of power data supplies specifically designed for Blast TR fixtures Visit www citytheatrical com for details City Theatrical Inc offers a line of polycarbonate holographic lenses for iW Blast TR with a range of symmetric and asymmetric beam angles Visit www citytheatrical com for details 13 5 in 343 mm 6 0 in 152 mm OE 7 mm i 2 0 in 51 mm 4 0 in 102 mm Replacement parts Included in the box iW Blast TR fixture with 6 ft 1 8 m leader cable Frosted glass 23 lens Clear glass 10 lens Protective elastomeric sleeve 3 16 in hex key wrench Installation Instructions You must remove the fixture s protective sleeve before you can attach the accessory holder Reinstall the protective sleeve after use Fixtures and Data Power Supplies iW Blast TR fixtures are part of a complete low voltage system which includes o
6. each with a leader a cable of up to 60 ft 18 m 0 03 2 75 2 On an architectural diagram or other diagram that shows the physical layout of 0 82 mm 70 mm the installation identify the locations of all switches controllers power data supplied fixtures and cables Start the Installation 1 Install all power data supplies including any interfaces with controllers Power Leader cable pinouts Id P d 4 si h Pin Signal Wire Color ies and extern ntrollers send power and control signals to the ata supplies and e e al cont p g UWE F fixtures over the fixture s leader cable 2 not used 2 Verify that all additional supporting equipment switches controllers is in place 3 Data White 4 DC Common Black 3 Ensure that all additional parts and tools are available including e The included 3 16 in hex key wrench for locking the fixtures in position e A Phillips head screwdriver for removing the bezel screws e C clamps or bases for pipe truss or floor mounting as required Install the Fixtures Make sure the power is OFF before mounting and connecting iW Blast TR fixtures 1 The mounting base of each iW Blast TR fixture provides a clearance hole for a 1 2 in bolt for mounting to a pipe truss weighted base or floor using a standard theatrical C clamp or other mounting hardware When mounting iW Blast TR ensure that the installation is suitable and safe and that the hardware is properly rated for th
7. 1872 25 542 35 201 45 94 55 54 65 30 75 10 85 0 90 0 22 5 44 67 5 6003 6003 6003 5278 5235 5189 1873 1879 1845 542 543 532 201 199 196 95 95 94 54 55 56 30 31 33 10 12 14 0 1 1 0 0 0 90 6003 5108 1799 520 191 IIluminance at Distance 4 3 ft 8 7 ft 13 ft 17 3 ft 21 7 ft 26 ft Center Beam FC 320 fc 80 fc 36 fc 20 fc 13 fc 9 fc 77 5 ft 23 6 m 1 fc maximum distance Beam Width 1 6f 1 6ft 33f 33ft 4 9ft 4 9 ft 6 5 ft 6 5 ft 8 2 ft 82ft 9 8 ft 9 8 ft Coefficients Of Utilization Zonal Cavity Method RCC RW M Vert Spread 21 3 EE Horiz Spread 21 4 Effective Floor Cavity Reflectance 20 80 70 50 30 10 0 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0 19 1 19 1 19 1 19 1 16 1 16 1 16 1 00 1 11 1 11 1 11 1 06 1 06 1 06 1 02 1 02 1 02 1 00 14 1 11 1 09 1 07 1 11 1 09 1 07 95 1 05 1 04 1 02 1 01 1 00 99 98 97 96 94 09 1 04 1 01 98 1 07 1 03 99 90 1 00 97 94 97 94 92 94 92 91 89 04 99 94 90 1 02 97 93 85 95 91 88 92 89 87 90 88 86 84 00 93 88 85 98 92 88 81 90 86 83 88 85 82 86 84 81 80 96 89 84 80 95 88 83 77 86 82 79 85 81 78 83 80 78 76 93 85 80 76 91 84 79 74 83 78 75 81 78 75 80 77 74 73 89 81 76 73 88 81 76 71 79 75 72 78 75 72 77 74 71 70 86 78 73 70 85 78 73 68 77 72 69 76 72 69 75 71 69 67 83 75 70 67 82 75 70 66 74 70 67
8. Height x Width x Depth Weight Housing Lens Fixture Connections Temperature Ranges Humidity Maximum Cable Length Certification Environment Details 235110 1469 23 beam angle 1679 10 beam angle 2700 K 6500 K 29 4 23 beam angle 33 6 10 beam angle 6 in 152 mm to uniform light 83 all 83 warm 74 cool 70 000 hours L70 25 C typical application 24 VDC via PDS 750 TRX PDS 375 TRX PDS 150e or PDS 60 50 W maximum at full output steady state DMX via power data supply Philips full range of controllers including Light System Manager iPlayer 3 or any third party DMX controllers 8x 13 5 x 2 6 in 203 x 343 x 66 mm 6 4 Ib 2 9 kg Die cast aluminium black powder coated finish Frosted glass 23 beam angle Clear glass 10 beam angle 6 ft 1 8 m power data cable with 4 pin XLR connector 40 122 F 40 50 C Operating 4 122 F 20 50 C Startup 40 176 F 40 80 C Storage 0 95 non condensing Up to 54 ft 16 5 m extension for total of 60 ft 18 3 m maximum UL cUL FCC Class B CE CCC C Tick Dry Location IP20 t Color temperatures conform to nominal CCTs as defined in ANSI Chromaticity Standard C78 377A i L70 70 lumen maintenance when light output drops below 70 of initial output Ambient luminaire temperatures specified Lumen maintenance calculations are based on lifetime prediction graphs supplied
9. e task 6 IW Blast TR Product Guide 1 4 O2 30 2 When mounting iW Blast TR fixtures on the floor or a base ensure that the fixture sits flush to the surface and use mounting hardware suitable for the mounting surface For complete instructions on how to wire sa the PDS 750 TRX refer to the PDS 750 TRX 3 Connect each iW Blast TR fixture to an available female 4 pin output on the Users Manual power data supply iW Blast TR fixtures are provided with a permanently connected 6 ft 1 8 m cable The leader cable can be extended with a standard XLR male to XLR female patch cable up to a maximum overall length of 60 ft 18 m GGGGG Exchanging IVV Blast R Lenses iW Blast TR is designed to let you quickly and easily exchange lenses The clear 10 lens is designed for long throw and spotlighting applications while the frosted 23 lens is designed for wash lighting applications The 23 lens is factory installed and the 10 lens is included in the box To ease removal and replacement of the protective cover run the fixture at full power until the heat from the fixture housing softens the cover material 1 Remove the protective cover from the fixture 2 Using a Phillips head screwdriver remove the two lock down screws located on each side of the fixture at the top of the bezel Do not remove the pivot screws on the edge of the bezel closest to the base 3 Using the tabs on the bezel pivot the
10. ends on the fixture s configuration iW Blast TR Powercore fixtures operate in 8 bit mode by default You can configure fixtures to operate in 16 bit mode which increases resolution for smoother dimming and more precise control In 8 bit mode fixtures use one DMX address per LED channel In 16 bit mode fixtures use two DMX addresses per LED channel The first DMX address corresponds to the coarse data for that channel and the second corresponds to the fine data By using double the number of DMX addresses 16 bit mode increases fixture resolution from 256 dimming steps to 65 536 256 x 256 dimming steps You can address and configure iW Blast TR Powercore fixtures in much the same way as you would address any RGB fixture The red channel corresponds to the warm LEDs the green channel corresponds to the cool LEDs and the blue channel is not used Note that although the blue DMX channel is not used it is assigned so that each iW Blast TR Powercore fixture uses three sequential DMX addresses or a multiple of three addresses iW Blast TR Powercore fixtures come factory addressed with a starting DMX address of 1 For lighting designs where fixtures work in unison all fixtures can be assigned the same starting DMX address Changes to the default starting DMX addresses are not necessary but if lights were previously readdressed for use in other installations you must reset them For light show designs that show different light o
11. es are designed for easy setup configuration and teardown You can connect iW Blast TR fixtures directly to a power data supply such as the PDS 750 TRX using the built in 6 ft 1 8 m power cable with standard XLR connector Owner User Responsibilities It is the responsibility of the contractor installer purchaser owner and user to install maintain and operate iW Blast TR fixtures in such a manner as to comply Refer to the iW Blast TR Installation with all applicable codes state and local laws ordinances and regulations Consult Instructions for specific warning and with the appropriate electrical inspector to ensure compliance GOO SEMLEMENLS Create a Lighting Design Plan 1 Determine the appropriate location of each power data supply in relation to the light fixtures and of the light fixtures in relation to each other iW Blast TR connects to the power data supply over a built in 6 ft 1 8 m leader cable with a standard 4 pin XLR male connector The leader cable can be extended with a standard XLR male to XLR female patch cable up to a maximum overall length of 60 ft 18 m The number of iW Blast TR fixtures that each power data supply can support is Leader Cable connector dimensions determined by such factors as the supply s capacity and number of available ports line voltage circuit load voltage drop and leader cable lengths The PDS 750 zi TRX for example can support up to 12 iW Blast TR fixtures
12. ezel and included 23 soft focus and 10 clear tempered glass spread lenses let you switch quickly between soft edge wash lighting and extended beam projection Photography Tom Boner e Quick fixture aiming and locking An industrial Rustic Kitchen Bistro amp Bar in Wilkes Barre PA shown grade constant torque hinge offers stable 110 above and on the cover films weekly cooking shows from its in house restaurant studio Twelve iW Blast TR fixtures suspended above the kitchen on a semicircular truss without special tools illuminate the on air host and guests with a precise shade of uniform white light During filming the color temperature can be adjusted on the fly to white balance the high fixture tilting for quick and dependable aiming Standard set screws lock the fixture in position e Versatile mounting options The pre assembled mounting base offers a range of options for definition cameras rendering colors on screen exactly as mounting on the floor or various stage truss they appear in person iW Blast TR lets studio chefs and clamps An integral safety bracket lets you easily patrons throughout the restaurant take advantage of high quality white light without the heat and power consumption attach a safety tether of conventional light sources e On board temperature monitoring A compensation circuit prevents damage to the P P 8 e Industry standard power and control iW Blast fixture i
13. f operatins temperatures rise to unsafe aa j amp 5 TR works seamlessly with the full range of Philips levels An auto cycling feature automatically DMX controllers such as iPlayer 3 ColorDial restores normal operation after 30 minutes P Pro or any third party DMX controller City Theatrical Inc offers a complete line of power data supplies specifically designed for use with iW Blast TR fixtures Innovative Protective Sleeve Because stage and set environments can take their toll on equipment iW Blast TR features an innovative elastomeric sleeve to protect the fixture and lens from the rigors of multiple setups and teardowns 2 IW Blast TR Product Guide iW Blast TR 23 frosted lens Lumens Efficacy 1469 29 4 Im W iW Blast TR 10 clear lens Lumens Efficacy 1679 33 6 Im W Photometrics Photometric data is based on test results from an independent NIST traceable testing lab IES data is available at www philipscolorkinetics com support ies Polar Candela Distribution Cd 0 1 006 2 012 3 108 4 023 5 029 6 035 VA 0 10 M 0H Zonal Lumen Zone 0 30 1 177 1 0 40 1 302 0 0 60 1 423 5 60 90 45 3 0 90 1 468 8 90 180 0 0 180 1 468 8 20 80 1 88 6 96 9 3 1 100 0 100 Total Efficiency 100 40 E 90 H Lumens Lamp Luminaire 80 1 88 6 96 9 3 1 100 0 100 90 80 70 60 50 0 O 6003 5 5236 15
14. k in place IW Blast TR Product Guide 9 10 IW Blast TR Product Guide IW Blast TR Product Guide 11 PHILIPS Philips Color Kinetics 3 Burlington Woods Drive Burlington Massachusetts 01803 USA Tel 888 385 5742 ELOT A2229 Fax 617 423 9998 www philipscolorkinetics com Copyright 2010 2012 Philips Solid State Lighting Solutions Inc All rights reserved Chromacore Chromasic CK the CK logo Color Kinetics the Color Kinetics logo ColorBlast ColorBlaze ColorBurst eW Fuse ColorGraze ColorPlay ColorReach iW Reach eW Reach DlMand EssentialWhite eW iColor iColor Cove IntelliWhite IW iPlayer Optibin and Powercore are either registered trademarks or trademarks of Philips Solid State Lighting Solutions Inc in the United States and or other countries All other brand or product names are trademarks or registered trademarks of their respective owners Due to continuous improvements and innovations specifications may change without notice Cover Photo Tom Bomer Rustic Kitchen Mohegan Sun at Pocono Downs Wilkes Barre Pennsylvania DAS 000012 00 RO3 05 12
15. ne or more power data supplies and any third party DMX controller Item iW Blast TR Protective Sleeve Mounting Base Lenses 23 frosted glass and 10 clear glass PDS 375 TRX PDS 750 TRX Accessories Item Number 501 000001 00 120 000062 00 120 000060 00 120 000066 00 109 000030 01 109 000030 00 Philips 12NC 910503700183 910503700370 910503700369 910503700367 910503702284 910503702319 Designed specifically for the family of Blast fixtures accessories provide additional options for controlling and dispersing light Accessory holders screw to the side of the fixture and are required for mounting accessories Accessory holders prevent accessories from falling out if the fixture is tipped or hung upside down Item Accessory Holders Half Top Hats Top Hats Egg Crate Louvers Barndoors Horizontal Glass Spread Lens Horizontal Vertical Glass Spread Lens Intended for use with Blast fixtures with 10 clear lens Type Black Black Black Black Black 36 ribs out 50 ribs in 40 Item Number 120 000003 04 120 000009 04 120 000005 04 120 000015 04 120 000019 04 120 000025 00 120 000025 01 iW Blast TR Philips 12NC 910503702840 910503702848 910503702844 910503702852 910503702856 910503703897 910503703898 Product Guide Use Item Number when ordering in North America 3 Installation iW Blast TR fixtur
16. utput on different fixtures simultaneously you must assign unique DMX addresses to your fixtures and sort them in a useful order The following table shows the DMX channel assignments for 8 bit and 16 bit iW Blast TR Powercore configurations assuming a starting DMX address of 1 DMX Channel Assignments 1 2 3 Warm Cool Unused 1 2 3 4 5 6 Warm Warm Cool Cool Unused Unused 8 bit Mode 16 Bit Mode 8 IW Blast TR Product Guide Safety cable bracket location on fixture Safety cable minimum requirements Material 316 Stainless Steel 5 64 to 3 16 in 2 to 5 mm nominal Size diameter Minimum break load must be greater than 400 Ibs 181 kg Construction 7 x 7 49 wires preformed stranded If necessary you can individually address iW Blast TR fixtures using QuickPlay Pro and SmartJack Pro You can download QuickPlay Pro and the Addressing and Configuration Guide from www philipscolorkinetics com support addressing LED Channels RGB iW Blast TR Powercore Red Warm Green Cool Blue Unused Do not look directly into the fixture when aiming and locking Aim and Lock the Fixtures Make sure the power is ON before aiming and locking iW Blast TR fixtures Using the provided hex key wrench loosen the tilting set screws located on the front of the fixture s mounting base Aim the fixture by tilting the beam as desired Tighten the set screws to lock the fixture in place FRONT VIEW Aim fixture and loc