1. CD CDe R C S FOOT SWITCHES PRESET W SPEED A VW DIMMER A A 5 1 Installation of LEGRAND ILME version ALL THE OPERATION OF INSTALLATION OR SERVICE MUST BE MADE BY QUALIFIED PERSONNEL This unit can accept two type of power supply e 220 240V 50 Hz supply MONO PHASE CONNECTION 1 PHASE NEUTRAL GROUND 380V 50 Hz supply TRHEE PHASE CONNECTION 3 PHASES NEUTRAL GROUND NOTE Channels 1 4 are connected to L1 phase channels 5 8 are connected to L2 phase The L3 phase is not internal connected Nominal load for each phase can not exceed 16 A 3500 W Total load when all the 8 output channels are on and with full light intensity can not exceed 32 A 7000W BEFORE INSTALLATION BE SURE THAT Power supply is capable to deliver enough power for the total load connected at outputs Power supply and lamps wires have a suitable section depending of their lenght and total current flow 5 2 INSTALLATION WITH MONO PHASE SUPPLY LEGRAND VERSION Unscrew the 2 fixing screw and remove protection plexiglass over the terminals block Connect the 3 wires of power supply cable in the screw terminals as show in fig 22 Fix through the 2 screw the protection plexiglass over the terminals block ILME VERSION Connect the 3 wires of power supply cable to a 3 POLES NEUTRAL GROUND 16A plug not included as show in fig 22 NOTE In mono phase operation the L1 L2 L3 terminals must be wired together through a suitable se
2. Next Js S fa lt na O vet SEQ UY SOOO Light Processor 8 Channels x 5 A Microprocessor controlled Digital dimmer Remote Control System USER S MANUAL INDEX 1 2 3 A 1 ul 1 Sets of the equipment 1 1 Unpacking of the equipment 1 2 Accessories issued with the equipment and relative documentation Description of the panels 2 1 Description of front panel 2 2 Description of rear panel LEGRAND version 2 3 Description of rear panel ILM E version Use of the equipment main functions 3 1 SEQuential mode 3 2 ON OFF mode Store a PRESET 3 3 PRESET mode 3 4 How to create and store a PRESET 3 5 Use PRESET as a scene 3 6 Use the PRESETS as a programmed sequence Use of the equipment secondary functions 4 1 CH OFF function 4 2 CH ON function 4 3 BANK function Internal memory organization 4 4 MIN function 4 5 FILL function 4 6 BLK function 4 7 BUZZER function 4 8 Description of external R C S control not included Installation of the equipment 5 1 Installation of LEGRAND ILME version 5 2 Connection with SINGLE PHASE supply 5 3 Connection with THREE PHASES supply 5 4 Connection of the output channels 1 1 Unpacking of the equipment Open the box take the equipment and the documentation out as show in the picture below 1 2 Accessories issued with the equipment and relative documentation Verify the contents of the packing If one of the following parts of t
3. To select another bank simply press one of the 1 8 keys rae To exit from this function without modify you must press any key except 1 8 Internal memory organization Internal memory organization is described in fig 13 It is composed by 64 total presets divided in 8 banks of 8 presets each one Only one bank can be activated at a time To select it use BANK function Each of the 8 presets of the active bank can be stored through MEM function in ON OFF MODE and recalled through 1 8 keys in PRESET MODE Fig 13 BANK 1 BANK 2 PRESET 1 PRESET 1 PRESET 2 PRESET 2 PRESET 3 PRESET 3 PRESET 4 PRESET 4 PRESET 5 PRESET 5 PRESET 6 PRESET 6 PRESET 7 PRESET 7 PRESET 8 PRESET 8 PRESET 1 i id PRESET 2 PRESET 3 i i PRESET 4 i i PRESET 5 i i PRESET 6 PRESET 7 i i PRESET 8 i i The memory is a non volatile type it can stores data without supply for more than 10 years 4 4 MIN FUNCTION THIS FUNCTION SELECT THE PRE HEAT VALUE FOR THE LAMPS NOTE This function is useful to increase the speed response of the Fig 14 lamps and to extend lamps life To select MIN function you must activate second function of keys pressing SHIFT Fig 14 yellow light on the SHIFT key on ha After press MIN key Fig 15 Now the OUTPUTS MONITOR lights shows the selected value of pre heat To select another value simply press one of the 1 8
4. age 4 as show in fig 24 The 2 ILME CONNECTORS ARE INTERNAL PARALLEL WIRED SO YOU CAN HAVE 1 STAND WITH 8 PROJ ECTORS 8 channels in one connector 2 STANDS WITH 4 PROJ ECTORS EACH ONE 4 4 channels in two connectors 2 STANDS WITH 8 PROJ ECTORS EACH ONE 8 8 channels in two connectors Fig 24 NEUTRAL blu N TERMINAL 9 10 par 2 2 ref 6 PHASE brown TERMINAL 1 8 par 2 2 ref 4 GROUND yellow green GROUND TERMINAL L par 2 2 ref 8 Is possible to connect one or more lamps in one channel verifing that TOTAL LOAD OF THE CHANNEL NOT EXCEED 5A 1100 W NOTE IT IS VERY IMPORTANT TO USE A SUITABLE SECTION WIRES TO CONNECT THIS EQUIPMENT TO THE LAMPS THE SECTION DEPENDS OF THE LENGTH OF THE CABLE AND THE LOAD OF THE CHANNEL THE NEUTRAL CABLE MUST HAVE A SECTION SUITABLE TO SUPPLY ALL THE CHANNELS CONNECTED TOIT THE SECTION OF NEUTRAL DEPENDS ALSO OF SUPPLY TYPE MONO PHASE OR THREE PHASES NOTE FOR ILME VERSION INSTALLATION The ground connection of output cable is executed inside the ILME connector through a screw CODEM MUSIC S r l Via Del Vallo 110 61100 PESARO ITALY Tel 39 0721 204357 Fax 39 0721 203554 http www codemmusic com E mail info codemmusic com All rights reserved No parts of this document can be copied photocopied or reproduced without the prior written permission of the CODEM MUSIC s r l No responibility is taken for possible inaccuracies or mistakes T
5. ces selection AE Light under the key indicate the activation of the function When activate each sequence is executed 4 times then the next sequence is selected Activate deactivate the flash effect Light under the key indicate the activation of the function eS Y KA 4 When activate the output channels remain on only for a short period of time Activate deactivate the music function Light under the key indicate the activation of the function A When activate the sequence run with music rhythm only if an audio signal is present on the rear music input BANK function par 4 3 allows to select one of the 2 bank of preprogrammed sequences available in SEQ function CB Bank 1 is preferred when all the 8 channels are in the same stand Bank 2 is preferred when the 8 channels are in the 2 stands 4 4 3 2 ON OFF MODE Store a PRESET EACH CHANNEL CAN BE ACTIVATE DEACTIVATE MANUALLY THROUGH 1 8 KEYS AND ALLOWS TO STORE A COMBINATION OF OUTPUT CHANNELS PRESET NOTE Be sure that SHIFT function are deactivate Fig 3 yellow light on the SHIFT key must be off Pressing ON OFF key the ON OFF mode is activated Fig 3 The green light on the key will light up to indicate the activation of the function Functions available in ON OFF mode 5 A Activate deactivate output channels 1 8 Fig 4 Functions available in SEQ mode after activate SHIFT function yellow light on the SHIFT key
6. ction wire Fig 22 NEUTRAL blu N TERMINAL par 2 2 ref 6 PHASE brown L1 L2 L3 TERMINALS par 2 2 ref 7 GROUND yellow green GROUND TERMINAL L par 2 2 ref 8 5 3 INSTALLATION WITH THREE PHASES SUPPLY LEGRAND VERSION Unscrew the 2 fixing screw and remove protection plexiglass over the terminals block Connect the 5 wires of power supply cable in the screw terminals as show in fig 23 Fix through the 2 screw the protection plexiglass over the terminals block ILME VERSION Connect the 3 wires of power supply cable to a 3 POLES NEUTRAL GROUND 16A plug not included as show in fig 23 THE WIRING IS STAR NEUTRAL TYPE 3 PHASES NEUTRAL Fig 23 NEUTRAL N TERMINAL par 2 2 rif 6 PHASE 1 L1 R i L1 TERMINAL par 2 2 rif 7 PHASE 2 L2 S L2 TERMINAL par 2 2 rif 7 NOTE L3 phase T is internal not PHASE 3 13 T connected so can be used to supply an audio system eliminating possible GROUND yellow green dimmer noises from L1 and L2 GROUND TERMINAL L par 2 2 rif 8 L3 TERMINAL par 2 2 rif 7 5 4 CONNECTION OF THE OUTPUT CHANNELS LEGRAND VERSION Unscrew the 2 fixing screw and remove protection plexiglass over the terminals block Connect all the projector s cable in the screw terminals as show in fig 24 Fix through the 2 screw the protection plexiglass over the terminals block ILME VERSION Connect all the projector s cable in the ILME socket accessory B p
7. ctions through an external control R C S input is J ACK MONO type and can accept R C S manual control or foot switches NOTE Connect in the R C S input only dedicated control build by Next use of another type of control can seriously damage the internal circuits OUTPUT CHANNELS CONNECTOR CHANNELS 1 8 Allows to connect the 8 output channels NOTE TOTAL LOAD FOR EACH CHANNEL CAN T EXCEED 5 A 1100 W OUTPUT CHANNELS CONNECTORS NEUTRAL Allows to connect the N NEUTRAL of the channels SUPPLY CONNECTOR N NEUTRAL Connector for N NEUTRAL wire of MONO PHASE or TRHEE PHASES power supply SUPPLY CONNECTORS L1 L2 L3 Connectors for L1 R L2 S L3 T wires of TRHEE PHASES power supply NOTE WITH MONO PHASE SUPPLY connect the phase wire to the three connectors L1 L2 L3 together CONNECTOR FOR GROUND WIRE Connect here the green yellow ground wire L 3 1 SEQuential MODE THE CHANNELS ARE ACTIVATED IN A PREPROGRAMMED SEQUENCE NOTE Be sure that SHIFT function are deactivate Fig 1 yellow light on the SHIFT key must be off CH OFF Pressing SEQ key the SEQ mode is activated Fig 1 sco The green light on the key will light up to indicate the activation of the function Functions available in SEQ mode Select one of the 8 sequences 9 Fig 2 Functions available in SEQ mode after activate SHIFT function yellow light on the SHIFT key on Fig 2 Activate deactivate the automatic sequen
8. e maximum and minimum SPEED or DIMMER is reached the light on the SHIFT key flashes 2 2 Description of the LEGRAND ILME rear panels LEGRAND version Next segur sooo mr LA popo op 9999 1 E of ome o o ra Faiy ys connect the Con alimentazione MO RB IONE pri mento Collegare SEMPRE il cavo di TERRA L ILME version O gt Next SEQUY 8000 524 helioa 220240 Vee aO ME TORT de ofS oe ous Q es is ll gg GE oe Me of ol o0 OUTPUT CHANNEL FUSES Each output has its fuse to protect the output stage of the unit and the lamp from short circuits or overvoltages If one or more output channels stop working verify the fuses par 7 7 MUSIC SIGNAL INPUT 0 dB This input allow to activate the unit with bass frequencies rhythm The connector is ACK MONO type connecting a J ACK STEREO type only one channel will be connected If the music signal is not present or not connected the MUSIC function will not work Music input has a automatic gain adjustment which allows to have always a signal level good for the equipment s working N B IT IS ABSOLUTELY FORBIDDEN TO CONNECT TO THIS INPUT ANY POWER SIGNALS FOR ACOUSTIC SPEAKER COMING FROM AMPLIFIED MIXERS OR AMPLIFIER R C S REMOTE CONTROL INPUT This input allows to control a lot of fun
9. e of the 8 preset you want to store the combination pressing one of the 1 8 key 7 Now you can store another preset starting from point 4 or recall the preset you have just created through PRESET mode par 3 3 3 5 Use a PRESET as a scene Storing in a preset an output channels combination this preset can be recalled everytime through PRESET mode par 3 3 For example if we want to have a specific lights combination in a room or in the stage We have 8 presets for each bank and therefore 64 total presets 3 6 Use the PRESETS as a programmed sequence Storing 8 presets in the same bank that creating a programmed sequence you can animate it To have automatic selection of presets you must select the PRESET mode par 3 3 and activate AUTO function par 3 3 Now you have create a programmed sequence that can be also utilized as a background selecting a low changing speed between presets With BANK function now you can select one of the 8 programmed sequences one sequence for every bank 4 1 CH OFF FUNCTION THIS FUNCTION TURN ALWAYS OFF ONE OF THE 8 CHANNELS To select CH OFF function you must activate second function of Fig 7 keys pressing SHIFT Fig 7 yellow light on the SHIFT key on After press CH OFF key Fig 8 If you execute exactly the operation the light on the CH OFF key blink W Now the OUTPUTS MONITOR lights shows the channels turned off Fig 8 To turn off or to put again in the normal s
10. e presets AE Light under the key indicate the activation of the function When activate the presets are executed one after the other After you have created the 8 presets in the same bank through this function you have a PROGRAMMABLE SEQUENCE Activate deactivate the flash effect Light under the key indicate the activation of the function a N When activate the output channels remain on only for a short period of time Activate deactivate the music function Light under the key indicate the activation of the function S When activate the sequence run with music rhythm only if the AUTO function is activated and an audio signal is present on the rear music input BANK function par 4 3 allows to select one of the 8 bank of programmable PRESETS When AUTO function is activated switching active bank allows to select one of the 8 programmable sequences of presets CB 3 4 Howto create and store a PRESET NOTE Be sure that SHIFT function are deactivate yellow light on the SHIFT key must be off 1 Activate ON OFF MODE par 3 2 2 If active deactivate FLASH function par 3 2 3 Select the BANK to store the preset through BANK function par 4 3 Once selected the active BANK will remain the same until we change it again 4 Create through 1 8 keys the combination of output channels 5 Activate the MEM function par 3 2 pressing first SHIFT key and after 2 6 Select on
11. he CODEM MUSIC s r l reserves the right to make any alterations or aesthetics changes of this product that seem necessary at any time and for whatever reason The CODEM MUSIC s r l takes no responsibility for the use or for the application of this product
12. he packing is missing or damaged please contact your dealer immediatly A User s manual B Screw terminals block for fast connection C Case for screw terminals block D Wire cather NOTE This accessories are standard only in 1 ILME version and are double only in 2 ILME version A 2 1 Description of the front panel OUTPUTS MONITOR CH ON BANK O O O 4 A A o E o e CH OFF Z id ig Ed a AR A seo J CE The OUTPUTS MONITOR lights shows the state of output channels and shows informations about secondary functions Turn on the equipment recalling all the settings Turn off the equipment storing all the settings in a non volatile memory A ia Activate SEQuential mode par 3 1 Activate CH OFF 2nd function with SHIFT key on par 4 1 mem Activate ON OFF mode par 4 1 on orr Activate CH ON 2nd function with SHIFT key on par 5 1 ZN LSO Activate PRESET mode par 3 3 preseT Activate BANK 2nd function with SHIFT key on par 4 3 er SHIFT Activate deactivate the 2nd function of the keys Activate various functions depending of the working mode Increase speed of the sequence in SEQ mode Increase the changing speed of presets in PRESET AUTO mode Decrease speed of the sequence in SEQ mode Decrease the changing speed of presets in PRESET AUTO mode Increase the light intensity of all the channels Decrease the light intensity of all the channels N B When th
13. his equipment from a remote position through a simple J ACK MONO gt J ACK MONO cable This system is very useful for everybody has busy hands Piano bar or to leave the unit on the stage and control it from mixer position with signal wired through extension box You have less wires for supply and lamps and a fast installation HAND R C S SEQ Press it for little time to activate BLK function par 4 6 C BIK J Press it for over than 1 5 seconds to activate SEQ MODE par 3 1 PRESET Press it for little time to activate FILL function v par 4 5 r Jojele Press it for over than 1 5 seconds to activate PRESET MODE v par 4 3 SPEED r DIMMER 4 Press it for little time to select sequence n 1 in SEQ MODE or preset n l in PRESET MODE Press it for over than 1 5 seconds to decrease the speed of y PRESET SEQ sequence in SEQ MODE or PRESET AUTO MODE FILL Press it for little time to select sequence n 2 in SEQ MODE or preset n 2 in PRESET MODE Press it for over than 1 5 seconds to increase the speed of sequence in SEQ MODE or PRESET AUTO MODE Press it for little time to select sequence n 3 in SEQ MODE or preset n 3 in PRESET MODE Press it for over than 1 5 seconds to decrease the light intensity of all the output channels Press it for little time to select sequence n 4 in SEQ MODE or preset n 4 in PRESET MODE Press it for over than 1 5 seconds to increase the light intensity of all the output channels cD CD
14. keys S Key 1 Pre heat OFF Key 2 Pre heat MIN Key 8 Pre heat MAX To exit from this function without modify you must press any key except 1 8 NOTE With inductive loads projectors with transformer is preferred to turn off pre heat Key 1 4 5 FILL FUNCTION THIS FUNCTION TURN ON ALL THE OUTPUT CHANNELS To select FILL function you must activate second function of keys Fig 16 pressing SHIFT Fig 16 yellow light on the SHIFT key on After press FILL key Fig 17 Now all the output channels are ON ha To return back to normal state simply press any key Fig 17 ES 4 6 BLK FUNCTION THIS FUNCTION TURN OFF ALL THE OUTPUT CHANNELS To select BLK function you must activate second function of keys Fig 18 pressing SHIFT Fig 18 yellow light on the SHIFT key on After press BLK key Fig 19 ha Red light under the key indicate the activation of the function Now all the output channels are OFF To return back to normal state simply press any key 4 7 BUZZER FUNCTION THIS FUNCTION TURN ON OFF THE BUZZER SOUND ON KEY PRESSING To activate deactivate BUZZER function you must activate Fig 20 second function of keys pressing SHIFT Fig 20 yellow light on the SHIFT key on After press BUZZER key Fig 21 Fig 21 e 4 8 DESCRIPTION OF R C S REMOTE CONTROL not included The R C S Remote Control System is an accessory that allows to control a lot of function of t
15. on Fig 4 Allows to store in one of the 8 presets of the active bank the state of the output channels W hen activate this function the OUTPUT MONITOR lights turn off Now you must select one of the 8 PRESET want to store the state of output channels simply pressing one of the 1 8 keys NOTE It is important to now what BANK 1 8 is active because all the operation regarding PRESETS read amp store will be referred to it par 4 3 To exit from this function without modify presets you must press any key except 1 8 Activate deactivate the flash effect 63 Light under the key indicate the activation of the function When activate the output channels remain on only for a short period of time NOTE It is not possible to activate MEM function with flash function active 3 3 PRESET MODE SHOW ONE OF THE 8 PRESETS OF THE ACTIVE BANK AND THROUGH AUTO MODE ALLOWS TO HAVE A SEQUENTIAL SELECTION OF THE 8 PRESET NOTE Be sure that SHIFT function are deactivate yellow light on the SHIFT key must be off BANK PRESET D Pressing PRESET key the PRESET mode is activated Fig 5 The green light on the key will light up to indicate the activation of the function Functions available in PRESET mode V 7 of Select one of the 8 presets Fig 6 Functions available in PRESET mode after activate SHIFT function yellow light on the SHIFT key on Fig 6 Activate deactivate the automatic selection of th
16. tate a channel simply press 1 8 keys CH OFF To exit from this function without modify you must press any key Fse except 1 8 Once turned off a channel it will remain in this state until you put it again in normal state through this function 4 2 CH ON FUNCTION THIS FUNCTION TURN ALWAYS ON ONE OF THE 8 CHANNELS To select CH ON function you must activate second function of Fig 9 keys pressing SHIFT Fig 9 yellow light on the SHIFT key on After press CH ON key Fig 10 If you execute exactly the operation the light on the CH ON key blink hal Now the OUTPUTS MONITOR lights shows the channels turned on Fig 10 To turn on or to put again in the normal state a channel simply CHON press 1 8 keys Bion To exit from this function without modify you must press any key except 1 8 Once turned on a channel it will remain in this state until you put it again in normal state through this function 4 3 BANK FUNCTION If activate from SEQ MODE SELECT ONE OF THE 2 BANKS OF PREPROGRAMMED SEQUENCES PAR 3 1 If activate from ON OFF MODE OR PRESET MODE SELECT ONE OF THE 8 BANKS OF PRESETS PAR 3 2 3 3 Fig 11 To select BANK function you must activate second function of keys pressing SHIFT Fig 11 yellow light on the SHIFT key on R After press BANK key Fig 12 If you execute exactly the operation the light on the BANK key blink Fig 12 Now the OUTPUTS MONITOR lights shows the ACTIVE BANK