PORTABLE EVAPORATIVE 3-in-1 AIR
Contents
1. 16 TECHNICAL SPECIFICATIONS 17 CUSTOMER SERVICE 17 WARRANTY aec 18 2 N WARNING Before using this air conditioner please read this owner s manual carefully This manual is not a contract and should be used as a reference guide only We reserve the right to make technical changes at all times without prior notice USE Thank you for purchasing this portable evaporative 3 in 1 Air Conditioner This unit is designed to improve indoor living and working comfort by providing cooling dehumidifying and ventilation with minimal installation Unlike traditional portable units there is almost no tank to emply as the unit evaporates 80 of the condensate water which is drained through the hot air exhaust hose This unit is designed for spot cooling or cooling a room no larger than 42m 450 sq ft with a standard 2 44 m 8 ceiling height When using this appliance always take basic safety precautions SAFETY NOTES 1 Always place the unit on a flat surface in a cleared out area 2 The unit must be connected to a grounded power supply properly rated For your safety this unit is grounded through the power cord plug when connected to a grounded wall outlet Never use an adapter plug or extension cord nor plug the unit in a damaged receptacle 3 Before unplugging the unit always turn it off Always unplug the unit before cleaning or servici
2. OWNER S MANUAL CANADIAN STANDARDS PORTABLE EVAPORATIVE 3 in 1 AIR CONDITIONER MODEL 13 04540 13 04553 KY 32U D Suny ise Tradex Corp www sunrisetradex com 3122 Bernard Pilon St Mathieu de Beloeil Qc J3G 4S5 RE oun Copyright Sunrise Tradex Corp 2005 00193 12 01 06 TABLE OF CONTENTS S Me 3 SAFETY NOTES 3 UNIT DIAGRAM gr 4 Sole van 4 Installation 4 INSTALLATION Electrical requirements 5 Preparing the air 5 Choosing the location 6 Fixing the exhaust 6 Wall installation eeeeee 6 Installation by window type 7 CONTROL PANEL AND LCD DISPLAY o o o n 8 Tas e fo 8 UNIT OPERATION COO acres cop 9 Dehumidifying cccccccccccsceessccessecessceesseeesesenseeensees 9 Eo TTA 9 LU F 10 Sleep Mode ssssseeen 10 Setting the TIMED OTT 10 REMOTE CONTROL restos d motam aes 11 12 13 WATER DRAINAGE 14 MAINTENANCE Cleaning the housing 15 Cleaning the filter eee 15 DIOR OG 15 TROUBLESHOOTING CHART
3. CASEMENT WINDOW Make sure to correctly install and insulate the window slider kit It must perfectly fit into the window The length can be adjusted The three pieces are easy to cut and slide well into each other Tape the edge around the slider kit to stop insect or bug intrusion tape not included NOTE Using the window slider kit may make it difficult to correctly close and or lock the window Additional safety precautions should be considered CONTROL PANEL AND LCD DISPLAY CONTROL PANEL 1 0 MODE a TEMP 20 amp Press this button to turn the unit on or off Press this button to select one of the following modes COOL FAN DRY or AUTO In COOL FAN or AUTO mode pe this button to select the fan speeds LOW MEDIUM HIGH In DRY mode the fan speed cannot be adjusted To set temperature in cooling or auto mode To set the time of hours when the timer is on Sets the air conditioner in SLEEP mode automatic shut off SLEEP n sleep mode automatic shut off AUTO Auto mode COOL In cooling mode am Eon 5 FAN 1 fan only mode ZEE LOW MEDIUM HIGH DRY In dehumidifying mode SET TIME Displays the hours set when SET TEMP Displays the set temperature timer is on ON Timer is on OFF Timer is off HEATING mode is optional only on some models 8 UNIT OPERATION Plug the pow
4. to be exposed directly to the unit cool air flow 17 Do not put any combustion appliance in the direct path of the unit airflow it could affect the combustion efficiency 18 Do not sit on the unit or place anything on the unit 19 Always store the unit standing up If the unit is to be moved or carried horizontally wait 24 hours before plugging the air conditioner 20 Before storing the unit in a clean and dry area drain the water and clean the filter UNIT DIAGRAM control inlet grille 222 electric cord hot air outlet lower air inlet grille water drain hole AW ANY idw Ht exhaust hose to unit vigor adaptor to window hose square adaptor e Electrical ratings of the air conditioner are detailed on the rating plate on the back of the unit e Basic electrical requirements are listed hereafter Please make sure to check the following before installing and connecting your unit ELECTRICAL REQUIREMENTS 1 The air conditioner must be grounded it is equipped with a LCDI Leakage Current Detection and Interruption power cord and plug Gs This feature will circuit trip the electrical power source if the nominal E current leakage between the cord shield and either load conductor 0 exceeds a predetermined value The cord will remain out of power 0 until the device is manually reset This is intended to protect against electric shock and to reduce the risk of a fire in the power
5. HOOTING Before asking for service please check the following troubleshooting chart PROBLEM The air conditioner does not work The indicator shows the air conditioner is running but it does not work Air cooling is not efficient LCD window shows an E1 error message LCD window shows an EA error The water tank is full message The unit is smelly The air conditioner is noisy Is the air conditioner leveled 2 and or vibrates There is water dripping on the inside floor 2 Power supply 1 Unit is not plugged in 2 The plug or receptacle is damaged The timer is on 1 The humidity of the room is under 30 2 There is frost on the evaporator 3 The air filter is dirty 4 The temperature is inadequate 5 Is there any heat source in the room 6 Is the hot air exhaust hose correctly installed Power supply is unstable and the unit is not working properly Is the air filter dirty Is the drain hose and the hose cap correctly installed NIEVER OPEN THE AIR CONDITIONER l Plug in correctly 2 Change the plug or receptacle Cancel the timer or wait for the unit fo start Increase the humidity level The unit is defrosting it will resume after the defrosting cycle is completed 3 Clean or change the filter 4 Increase the temperature and the fan speed 5 Close or move the heat N e source 6 Check the installation of the hot air
6. NTABILITY ARE LIMITED TO A TWO YEAR 2 PERIOD COVERED BY THIS EXPRESS LIMITED WARRANTY SUNRISE TRADEX CORP DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SUNRISE TRADEX CORP LIABILITY EXCEEED THE RETAIL VALUE OF THE AIR CONDITIONER FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS PORTABLE AIR CONDITIONER Keep this owner s manual along with your proof of purchase in a safe place for future reference You must provide proof of purchase for warranty service Enter the following information on your air conditioner it will help you upon getting assistance or service if you ever need it You will have then to provide the model and serial numbers of the air conditioner these data are detailed on the rating plate of the unit Dealer name Address Model number 13 04540 13 04553 KY 32U D Serial number Date of purchase 18
7. NTIL AUTO LIGHTS UP ON THE CONTROL PANEL e Exhaust hose drain hose and cap hose must be correctly installed in AUTO mode e The TIMER may be used in AUTO mode SLEEP MODE When setting this mode the air conditioner will automatically shut off in 7 hours This is a fast way to program an automatic shut off of the unit for the night for an optimal room comfort it is also energy saving 1 Unit must be runnina when using this mode 2 Press on the SLEEP i button until the SLEEP icon lights up on the pannel 3 The air conditioner will automatically shut off after 7 hours 4 For programming a shut off in less than 7 hours use the TIMER button to adjust the delay by 1 2 hour slot up to 7 hours maximum The LCD display will show the set time 5 To cancel press again the SLEEP button until the SLEEP icon goes off e When the SLEEP mode is on you can still modify program any other function on the unit You cannot set the TIMER ON for an automatic shut off if the unit is in SLEEP mode e The SLEEP mode cannot be used if the air conditioiner is in AUTO mode SETTING THE TIMER When the unit is operating the timer can be used to set an automatic shut off time If the unit is off but still plugged the timer can be used to set an automatic start time AUTOMATIC STARTING 5 1 While the unit is off press the TIMER button until the TIMER ON icon lights on 2 Press the up down arrows on the TIMER button i to set th
8. cord or combustible materials nearby The cord shield is not grounded and must be considered a shock hazard if exposed The cord shield must not be connected to ground or to any exposed metal 2 Do not cut or bypass the plug ground prong If you do not have a grounded outlet available near the air conditioner have one installed by a qualified electrician 3 The power supply rated voltage is 6 4 Do not connect the unit to an outlet being used by other appliances ideally connect to a single grounded 15A circuit time delay fuse or circuit breaker 5 If the power cord or plug is damaged call SUNRISE TRADEX Customer Service PREPARING THE AIR CONDITIONER FIXING THE CASTERS To avoid the risk of causing damages to the air conditioner you must install the casters before using the appliance 1 Open the accessory bag and take the 4 casters out 2 Recline the unit one side at a time to insert the unit into the base holes Do not recline the unit more than 45 from the ground 3 Screw the casters into the base threaded holes INSTALLATION OF THE DRAIN HOSE You must fix the drain hose before operating the unit 1 Take out the drain hose the hose cap and the clamp from the accessory bag 2 Insert the drain hose into the drain hole on the lower back of the unit Make sure that the drain hose is correctly inserted into the drain hole 3 Put the hose cap on the free end of the drain hose 4 Fix the drain ho
9. e To change the time press on Hr the hour icon will flash set the hour then press on Min to set the minutes the minute icon starts flashing and the hour icon stops flashing set the minutes then press on SEND the minute icon will stop flashing IMPORTANT always check and set the clock at the right time before initiating the timer or the sleep mode do nof forget to press on SEND SLEEP MODE This mode is a fast way to set a 7 hour time delay automatic shut off of your air conditioner 1 Set this mode when the air conditioner is running 2 Press on SLEEP the SLEEP icon will appear on your remote display your air conditioner will automatically stop running in 7 hours If you want an earlier shut off press on Hr the hour icon will flash you may increase the time 1 hour at a time up to 7 hours 5 Press on SEND a beep will confirm transmission and the hour icon will stop flashing and the remote LCD screen will display the time left before the shuf off of the air conditioner 6 To cancel the SLEEP mode simply press on SLEEP again the SLEEP icon will go off then press on SEND For other operational settings proceed as detailed previously WATER DRAINAGE When the unit is in cooling mode the air humidity is converted in water used to cool down the unit 80 of the water is condensate and evaporated outdoor through the exhaust hose When the unit is used in extremely humid environment exceeding
10. e outside air outlet Unscrew the hose connector cut the excess hose and screw the connector back on the hose Do not forget to leave a 50 cm 20 clearance all around the air conditioner To maximize the efficiency of the air conditioner you may insulate the exhaust hose with a 6 insulating flexible tube 130 cm 50 40 cm 16 Figure C Figure D INSTALLATION BY TYPE OF WINDOW Casement window l It is recommended to replace the screen with a clear plexiglass panel 1 4 fitted to the size of your window screen 2 Cut a hole to the same size as the window oval adaptor of the exhaust hose approximately 13 3 cm 5 1 4 3 Correctly fit on the adaptor 4 Fix it on the plexiglass using 4 screws not included Sliding windows or patio door 1 Install the window slider kit vertically or horizontally within the inside frame vertically for a patio door If necessary screw the slider kit on the frame 2 Close the window onto the window kit to form a tight seal 3 Attach the exhaust hose adaptor to the window slider kit the adaptor tabs will lock into place the adaptor to the window kit HUNG SLIDING WINDOW WINDOW or PATIO DOOR jl
11. e time number of hours before the air conditioner turns 1 24 hours LCD display will show the set time 35 AUTOMATIC SHUT OFF While the unit is running repeat steps 1 and 2 as detailed previously for an automatic shut off To cancel the timer whether you are programming an automatic start or shut off of the air conditioner simply press on the TIMER C button until the OFF icon lights on REMOTE CONTROL You can control your air conditioner from a distance with the remote control provided with your unit The remote can control the same functions than those operated directly from the unit on the control panel Before using the remote do not forget to insert 2 AAA 1 5V batteries included How to insert the batteries e Following the arrows shown in the figure remove the battery cover e Insert the 2 batteries making sure that the terminals are correctly fitted Put the cover back into position Note Always use 2 AAA 1 5V battaries Replace batteries with new ones when the LCD display of your remote is fading out USING THE REMOTE Always line up the remote signal transmitter with the unit signal receiver on the front panel e The LCD display of the remote will show all the messages and icons you may need to control your air conditioner from a distance All operational functions of your remote as well as message and icon identification are described in the next 2 pages e After en
12. er cord into a properly rated grounded outlet Do not connect the unit to an outlet that is being used by other electrical appliances e Then press the I O button to begin operation e When starting tn air conditioner always set the unit to COOL and the temperature to the coolest degree 16 C 61 Let it run with for 2 hours e When the desired room confort level is reached adjust the fan speed to maintain this temperature and adjust temperature accordingly if necessary e Since the air conditioner takes few hours to cool off the room it is recommended to let the air conditioner work 24 24 h and adjust the temperature instead of stopping and starting the air conditioner on a daily basis e f the unit is turned off while running in COOL DRY or AUTO mode when turning the unit back on allow 3 minutes before the compressor resumes COOLING 1 Press the MODE button and set until the COOLING icon AS lights up 2 The display will show the set temperature Press on the temperature button to set the temperature 16 C to 31 C 61 F to 88 F 3 Press FAN SPEED 5 to set fan speed at LOW MEDIUM or HIGH each speed level is identified by an icon lighting up when selected fll e When the room temperature is slightly warmer than the set temperature the compressor starts running and the air conditioner cools the room off When the room temperature is slightly colder the compressor stops but the fan keeps on runnin
13. exhaust hose and insulate it Stop the air conditioner switch off the power supply Wait 10 minutes and turnit back on if Elis still on call SUNRISE TRADEX Service Drain out and empty the water tank Clean the air filter as well as the front and back grills Make sure the air conditioner is on level and flat surface Secure the installation of the drain hose and the hose cap and make sure the unit is on a level surface TECHNICAL SPECIFICATIONS Specifications listed hereafter are for references only Please see technical data on your air conditioner unit rating plate Cooling capacity 1 12000 BTU H Dehumidifying capacity 53L 14 Gal day Watts Dehumidifying 1200 W Air flow volume cubic metre h 2 330 M h Net Weight Gross Weight 43 Kg 95 Ib 45 Kg 99 b Unit 86 H x 45 W x 37 D cm 3A4 H x 18 W 15 D Package 113 H x 54 W x 49 D cm AA 21 W x 19 D Note 1 Cooling capacity is measured at ambient temperature DB 30 WB 25 5 C 2 Fan airflow is measured when fan runs at highest speed 3 Noise level is measured in cooling mode 1 0 metre away from front of the air conditioner CUSTOMER SERVICE Contact SUNRISE TRADEX CORP Customer Service for Replacement parts Technical support e Warranty claims Any other service or request on other SUNRISE products Suny ise Tradex Corp www sunrisetradex com 3122 Bernard Pilon St Mat
14. g e The exhaust hose must be correctly installed and that the air inlet and outlet grilles must be cleared out e Make sure that the drain hose and cap are correctly installed For maximum efficiency draw the curtains or blinds if the room is exposed to direct sunlight Do not place near a heat source DEHUMIDIFYING PRESS THE MODE BUTTON UNTIL THE DEHUMIDIFYING I e The exhaust hose must be correctly installed In dehumidifying mode the fan runs at low speed and speed cannot be changed e Make sure that the drain hose and cap are correctly installed The unit will not operate if the room temperature is lower than 16 C 61 F For maximum dehumidifying efficiency keep windows and doors closed 4 Aa i LIGHTS UP FAN s 1 Press the MODE V button and set until the FAN icon S lights up 2 Press FAN SPEED A to set fan speed at LOW MEDIUM or HIGH each speed level is identified by an icon lighting up when selected atii In FAN mode the exhaust hose is inoperative UNIT OPERATION AUTO MODE The unit built in microcomputer analyses the temperature and humidity level in the room the air conditioner controls and automatically adjusts the cooling system compressor on or off and the fan speed This selfadjustment feature allows you to maintain room comfort by con trolling the temperature and air dehumidification in the room Re Ps To set iN AUTO MODE PRESS THE MODE i BUTTON U
15. hieu de Beloeil Qc J3G 4S5 Tel 450 536 2175 Fax 450 536 9081 Toll free 1 800 686 2175 WARRANTY LIMITED WARRANTY This air conditioner is covered by a warranty against defects in materials and workmanship if used for the applications specified in this owner s manual for a period of TWO 2 years from the date of original purchase in Canada Note The internal compressor is covered by a 5 year limited warranty During the warranty period if the air conditioner fails under normal use SUNRISE TRADEX CORP will at its option either repair the unit or replace it free of charge within a reasonable period of time after the air conditioner is returned As a condition to any warranty service obligation the customer must present this warranty certificate along with the proof of purchase THIS WARRANTY DOES NOT COVER 1 Damage accidental or otherwise to the air conditioner that are not caused by material or workmanship defect 2 Damage caused by misuse tampering or failure to follow the operating and maintenance instructions provided in this owner s manual 3 Damage to the finish of the unit enclosure or to other outer features caused by wear 4 The filter 5 Damage caused by repairs or modifications to the air conditioner made by any person not duly authorized by SUNRISE TRADEX CORP 6 Insurance and freight costs for the warranty service ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHA
16. ng it When unplugging the unit never pull on the power cord always grip the plug Ensure that removable covers hoses and other accessories are correctly fitted before running the unit 5 Do not install or use the unit in the following places near a heat source an area with possible gas leakage or in an explosive atmosphere near bath shower enclosure swimming pool or any other steamy and wet areas in a greenhouse 6 Do not apply insecticides or any other flammable products on the unit 7 Do not start or stop the unit by plugging in or pulling out the power cord 8 Do not operate with wet hands or spray water or other liquid on the unit nor immerse the appliance 9 This unit is not intended for the use of children and close supervision is necessary when it is operating near children 10 Never insert fingers foreign objects or anything to obstruct the air inlet and outlet grills Always warn children 11 Do not cover the appliance 12 Do not expose skin or eyes directly to cool air over a long period of time 13 If an abnormal odour or smoke comes out of the unit immediately unplug the unit and contact SUNRISE TRADEX Customer Service 14 When opening the filter cover do not touch the internal metal parts of the unit 15 Always check the power cord for signs of damage before use If the power cord is damaged contact SUNRISE TRADEX Customer Service 16 Do not place a plant or allow a pet
17. on TO SET THE MODE e Press on MODE until the matching icon flashes on the remote LCD display 3t for COOLING mode 9 for FAN ONLY mode ou A for the AUTO mode e Press on SEND to initiate the operation on the air conditioner a beep will confirm transmission and the icon will stop flashing IMPORTANT some screen may display a sun icon for HEATING mode this mode is available only on some models TO SET FAN SPEED e Press on FAN and choose the speed HIGH M Medium or LOW each speed icon will flash Press on SEND a beep will confirm transmission and the speed icon will stop flashing TO SET TEMPERATURE e Press on or OC to set the desired temp rature the temperature icon will flash The temperature is increased or decreased by 19 each time you press on these buttons The temperature settings range from 16 C to 30 C 619F to 86 F Press on SEND a beep will confirm transmission and the temperature icon will stop flashing NOTE all the above operations can be keyed in on the remote control before pressing on SEND to initiate the operations on the air conditioner EX to set your air conditioner in COOLING mode at HIGH fan speed and at 22 C press on MODE until the COOLING flashing icon shows on the LCD display e then press on FAN until the HIGH flashing icon shows on the display when pressing on FAN the cooling icon will stop flashing e then press on 9 C un
18. rect exposure to sunlight as this may affect the finish colour BACK OF THE UNIT CLEANING THE FILTER Open the rear grille of the air conditioner and take the filter out Immerse the filter gently in lukewarm water and a mild detergent Rinse thoroughly let it dry completely and put the filter back For maximum efficiency of the air conditioner clean the air filters every two weeks or more frequently if there are animals around If the filter is damaged or used contact SUNRISE TRADEX Customer Service Filter cover hooks Filter cover STORAGE e Turn the unit off and unplug e Drain all condensate water from the unit e Turn the unit to fan mode for a couple of hours to completely dry out the inside e Clean the filter e Wind the power cord to the hangers Always store the unit upright in a clean and dry aera It is recommended to store the unit in its original packing carton Notes e If the unit is not used on a regular basis it is recommended to turn it on once in a while to keep the compressor in good working condition e After running for several seasons the air conditioner internal components may get dirty and or obstructed the unit may become less efficient Regular maintenance is recommended Contact SUNRISE TRADEX Customer Service for maintenance or repair 15 TROUBLE S
19. se on the rear grille with the clamp Rear grille Drain hose CHOOSING THE LOCATION Place the unit on a level surface in a cleared out area where the air outlets cannot be obstructed For a maximum efficiency keep a clearance of at least 50 cm 20 front and rear of the unit Figure FIXING THE EXHAUST HOSE e During the operation of an air conditioner a large flow of hot air must be exhausted out of the room The exhaust hose supplied with this air conditioner must be connected at all times when running in air conditioning mode to exhaust the hot air out SLIDE THE HOSE SQUARE ADAPTOR ALL THE WAY DOWN OVER THE HOT AIR OUTLET ON BACK OF THE UNIT Figure WALL INSTALLATION e The hot air must be exhausted outdoor through a window a patio door or directly through the wall 1 Pick an exterior wall where you will be able to correctly install the air conditioner and the hot air outlet 2 Drill a hole of 13 3 cm 5 1 4 on the exterior wall The hole must be 40 to 130 cm 16 tp 50 above the floor figures C 3 Fix the external end of the exhaust hose onto the wall pre drilled hole NOTE The hot air exhaust hose must be as short as possible To avoid hot air backdraft and guarantee an efficient exhausting of the hot air make sure the hose is not bent kinked or twisted Figure D In order to do so please check upon the following e Position the air conditioner as close as possible to th
20. tering a mode or function on your remote always press on SEND to initiate the command on the unit You will hear a beep from the unit meaning that the function has been received and initiated e When keying a function or mode on the remote the identification icon or message flashes on the remote LCD display and stops flashing when the SEND bution is pressed POWER FAILURE In case of a power failure during operation all settings programmed directly from the unit will be cancelled e However the remote control will keep in memory the last settings programmed on the remote control To resume operations simply press on SEND e If the air conditioner does not work properly unplug the unit and plug it back Wait 3 minutes and then turn the unit on e Press SEND on the remote control to resume last operations set from the remote 11 REMOTE CONTROL LCD DISPLAY SEND initiate all operations of the air conditioner FAN to set fan speeds MODE to set the air conditioner in AUTO COOL or FAN mode SLEEP to set the air con ditioner in SLEEP mode TIMER to set the timer or the clock time DRY to set in To set the number of hours DEHUMIDIFYING mod when the timer is on or the oC time clock to set temperature ON OFF to start or close the air conditioner Product may differ from picture or line art TO START OR STOP THE AIR CONDITIONER Press on the I O ON OFF butt
21. til you reach 229 the temperature icon will flash and the FAN icon will stop flashing to complete press on SEND a beep will confirm transmission and the temperature icon willl stop flashing 12 REMOTE CONTROL DEHUMIDIFYING MODE e Press on DRY to set the air conditioner in dehymidifying mode will show on the remote control LCD display press on SEND To cancel this mode simply press on DRY again In DRY dehumidifying mode the compressor is running but the fan speed cannot be changed TIMER AND TIME CLOCK When pressing on TIMER you may select TIMER to put the timer on and set the number of hours or you may select TIME CLOCK to set the current time TO SET THE TIMER For an automatic start of the air conditioner 1 Press on TIMER the TIMER icon will flash and the LCD display will show 0 5 if there have been no previous setting otherewise the display will show the time set previously number of hours 2 Press on Hr the number of hours icon will flash and the TIMER icon will stop flashing keep on pressing Hr to set the number of hours 1 24 before the air conditioner starts From O to 8 time will increase by 1 2 hour from 8 to 24 it will increase by 1 hour 3 Press on SEND a beep will confirm transmission and the time hours icon will stop flashing TO SET THE TIME CLOCK e Press on TIMER until the TIME icon flashes the LCD screen will display the current tim
22. water will be drained into a pan located at the bottom of the unit When the water pan is full the compressor stops but the fan keeps on running When the water pan is full an overflow alarm will beep and the LCD display will show an E4 message meaning that the tank is full and the unit will stop running To resume operation empty the water tank as per the following 1 Turn the unit off Do not move the unit when the water pan is full 2 Unclamp the drain hose from the rear grille 3 Place a 2L container under the drain hose 4 Remove the cap from the drain hose The condensate water will drain out automatically When the 2L container is full put the cap back into the drain hose to stop the water from draining out Empty the 2L container Repeat until all the water is completely drained out 4 Once the water container is empty put the cap back into the drain hose and clamp the hose back on the grille Back grille EE zzz E Drainage EE port 2L container Always turn off and unplug the unit before cleaning to avoid electrical shock CLEANING THE HOUSING e Wipe the surface of the unit with a soft damp cloth Cleaning the unit with gasoline paint thinner chemical products or abrasive detergent could damage it Use mild soap Do not clean the air conditioner directly under a faucet or with a garden hose its electrical components could be damaged and cause electric shocks Avoid di
Download Pdf Manuals