Home
Door/Window sensor
Contents
1. group 3 Default value 0 Basic Size 1 byte Possible values 0 Basic 1 Switch Binary 2 Switch All 3 Switch Multilevel Parameter no 5 Select what value that should be sent to association group 3 Default value FF Last value Size 1 byte Possible values 0 63 Dim level FF Last value Parameter no 6 Type of commands to association group 3 Default value 0 Normal Size 1 byte Possible values 0 Normal 1 Inverted Parameter no 7 LED Indicator Default value 1 On Size 1 byte Possible values 0 Off 1 On Parameter no 8 Select the type of command to be sent in the Lifeline Default value 0 Notification Size 1 byte Possible values 0 Notification 1 Sensor binary Wake up Since this is a battery operated device it will sleep most of the time making it not listening for new settings etc Press the button on the sensor one time short to wake up the device Node Information Frame The Node Information Frame contains information about the device type and the technical capabilities The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node Information Frame Tripple click the button on the device to send out a Node Information Frame Supported Command Classes Sensor binary version 2 Association group info version 1 Device reset locally version 1 Z Wave Info vers
2. Door Window sensor User Manual This magnet sensor contains the latest Z Wave technology with the ability to remotely control other Z wave units available in your network The fact that it is battery operated and so small you can virtually place it anywhere you want on doors windows or drawers without the need of wiring Screw or tape up the holder and then click the sensor in place Done The sensor is designed to be seen as little as possible and we have made it significantly smaller than other sensors It consists of two parts that will merge into a stylish unit when the sensor is closed This device can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network Specification Battery 1 pcs 1 2 AA 3 6 V ER14250 Range Up to 30 meters indoor Operating temperature 0 40 C Frequency 868 42 MHz EU Protection Class IP20 Terminology Add The process of including a node into the Z Wave network Remove The process of excluding a node from the Z Wave network Installation Remove the battery protection slip to start the sensor Mount the sensor where it s supposed to operate using the supplied adhesive tape or the supplied screws Include the sensor into your Z Wave network By doing it where it s supposed to operate th
3. e mesh network will be set up correctly Add device This device can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network When the device is not added to any Z Wave network the LED will flash slowly when it s awake If the device already is added to a Z Wave network follow the remove device process before adding it to your network Otherwise adding this device will fail Automatically add device to network When a battery is inserted the device is in automatical add mode for one minute Network Wide Inclusion NWI This means that the device is added automatically when the Z Wave controller enters add mode Manual add device to network Start the add mode on the Z Wave controller Press the button on the device three times fast The device will now be added into the Z Wave network Remove device Start the exclusion mode on the Z Wave controller Press the button on the device three times fast The device will now be removed from the Z Wave network Reset the device Method 1 Remove the device from the Z Wave network This will reset the device to factory defaults Method 2 Reset the device by 1 Press and hold the button until the LED starts flashing approx 6 seconds 2 Press the button once more short The d
4. ensor and a Basic Command ON FF when the magnet is approaching the sensor Associations Association group 1 Lifeline Sensor status Max 1 node The sensor will send it s status to the node in this group whenever the status of the sensor changes Lifeline is normally used to send the device status to the main controller gateway Association group 2 Sensor status Max 10 nodes The sensor will send control commands to nodes in this group when the status of the sensor changes Association group 3 Sensor status Max 10 nodes The sensor will send control commands to nodes in this group when the sensor is opened only Configurations By changing configurations you are able to change various settings in the device This can be done from the Z Wave gateway controller if it s supported These settings are available in this device Parameter no 1 Select what type of command to be sent to nodes in association group 2 Default value 0 Basic Size 1 byte Possible values 0 Basic 1 Switch Binary 2 Switch All 3 Switch Multilevel Parameter no 2 Select what value that should be sent to association group 2 Default value FF Last value Size 1 byte Possible values 0 63 Dim level FF Last value Parameter no 3 Type of commands to association group 2 Default value 0 Normal Size 1 byte Possible values 0 Normal 1 Inverted Parameter no 4 Select what type of command to be sent to nodes in association
5. evice will now reset to factory defaults The LED will now flash indicating that it s no longer added in any Z Wave network This procedure is called Device Reset Locally Operating the device The sensor will send it s status to the primary controller as long as it s included in association group 1 Lifeline The sensor can control other devices that is included in association group 2 or 3 Devices in association group 2 will be controlled when the sensor is opened and closed devices in association group 3 will only be controlled when the sensor is opened LED indicator Please note that the LED might has been turned off configuration 7 set to 0 making the LED not light up at all Not in network Slowly flashing only when the device is awake Open close Short flash Wakeup LED lit as long as the sensor is awake Basic Command Class The Door Window sensor can control other devices using the Basic Command Class Associate the nodes using association group 2 or 3 The normal behavior is to send out a Basic Command ON FF when the magnet is removed from the sensor and to send out a Basic Command OFF 00 when the magnet is approaching the sensor The value that is sent out when the magnet is removed can be changed by setting configuration parameter 2 and 5 The behavior can be inverted by setting configuration parameter 3 and 6 When inverted the sensor will send out a Basic Command OFF 00 when the magnet is removed from the s
6. ion 2 Configuration version 2 Alarm version 4 Manufacturer specific version 1 Powerlevel version 1 Firmware update version 2 Battery version 1 Wake up version 2 Association version 2 Version version 2 Multi channel association version 2